Zoning and Platting Commission Homepage

RSS feed for this page

Dec. 6, 2022

10 C8-2022-0254.0A - 1191 Ridge Drive Subdivision; District 1.pdf original pdf

Thumbnail of the first page of the PDF
Page 1 of 11 pages

SUBDIVISION REVIEW SHEET CASE NO.: C8-2022-0254.0A COMMISSION DATE: December 6, 2022 SUBDIVISION NAME: 1191 Ridge Drive Subdivision ADDRESS: 1191 Ridge Drive APPLICANT: Tejas 1 QOZB, LP. (Gary G. Gill) AGENT: Southwest Engineering, Inc. (Kody Schouten) ZONING: SF-3-NP (single family) NEIGHBORHOOD PLAN: M.L.K. AREA: 0.52 acre (22651.2 sf) LOTS: 6 COUNTY: Travis DISTRICT: 1 WATERSHED: Boggy Creek JURISDICTION: Full Purpose SIDEWALKS: Sidewalks will be constructed along streets. VARIANCE: None DEPARTMENT COMMENTS: The request is for the approval of 1191 Ridge Drive Subdivision final plat comprised of 6 lots on 0.52 acres (22651.2 sf). The plat does not comply with the criteria for approval in LDC 25-4-84(B) and staff recommends disapproval for the reasons listed in the attached comment report. An application that has been disapproved with reasons may be updated to address those reasons until the application expires. If the applicant submits an update to address the reasons for disapproval, that update will be presented to the Land Use Commission within fifteen days of submittal. STAFF RECOMMENDATION: Staff recommends disapproval of the final plat for reasons listed in Exhibit C in the support material. CASE MANAGER: Cesar Zavala PHONE: 512-974-3404 E-mail: cesar.zavala@austintexas.gov ATTACHMENTS Exhibit A: Vicinity map Exhibit B: Proposed final plat Exhibit C: Comment Report ` 1 of 1110 Location Map 1191 Ridge Drive, Austin, Texas 78721 2 of 1110 0' 30' 60' LEGEND PROPERTY CORNER FOUND AS NOTED SET 1/2" ROD WITH ORANGE PLASTIC CAP RPLS 5367 SITE BOUNDARY ADJOINER PARCEL LINE RIGHT OF WAY LINE JUAE JOINT UTILITY/ACCESS EASEMENT SIDEWALK TO BE CONSTRUCTED PUE PUBLIC UTILITY EASEMENT WWE WASTE WATER EASEMENT 1191 RIDGE DRIVE SUBDIVISION 0.517 ACRE PARCEL BEING A PORTION OF LOTS 2 AND 3, SAM HUSTON HEIGHTS, ACCORDING TO THE MAP OR PLAT THEREOF FIELD FOR RECORD IN VOLUME 3, AT PAGE 249, PLATS RECORDS, TRAVIS COUNTY TEXAS (P.R.T.C.), CITY OF AUSTIN, COUNTY OF TRAVIS, STATE OF TEXAS ELNITA M. LEE DOC. NO. 2004233353 PART OF LOTS 1-3 SAM HUSTON HEIGHTS VOL. 03, PG. 249 LESLIE A. MARTINE DOC. NO. 2005144153 LOT 1, BREEDLOVE ADDITION VOL. 05, PG. 71 N 2 7 ° 2 5 ' 3 2 " W 1 3 1 . 9 2 ' POINT OF BEGINNING 1/2" IRON ROD W/ PLASTIC CAP MARKED "CAPLUGS B-14" COTTON SPINDLE 1/2" IRON ROD W/ PLASTIC CAP MARKED "DEAN WOODLEY" N 78°36'24" E 89.04' 3.85' PUE10' 4 3 . 9 6 ' 10' SANITARY SEWER EASEMENT …

Scraped at: Dec. 2, 2022, 9:55 a.m.
Dec. 6, 2022

11 C8J-2020-0057.1A - Slaughter Lane 90 Acre Tract, Phase 1 Small Lot Final Plat.pdf original pdf

Thumbnail of the first page of the PDF
Page 1 of 9 pages

SUBDIVISION REVIEW SHEET LOT(S): 127 COUNTY: Travis JURISDICTION: 2-Mile ETJ ZAP DATE: December 6, 2022 (William Peckman) AGENT: LJA Engineering, Inc (Russell Kotara) CASE NO.: C8J-2020-0057.1A SUBDIVISION NAME: Slaughter Lane 90 Acre Tract, Phase 1 Small Lot Final Plat AREA: 64.8855 acres OWNER/APPLICANT: M/I Homes of Austin, LLC ADDRESS OF SUBDIVISION: Slaughter Lane GRIDS: J11 WATERSHED: Marble Watershed EXISTING ZONING: N/A MUD PLAN: N/A PROPOSED LAND USE: 123 single family lots, 4 open space/water quality/PUE/drainage/landscape/park easement lots, and public ROW VARIANCES: None SIDEWALKS: Sidewalks will be provided along all internal streets and the boundary street. DEPARTMENT COMMENTS: The request is for the approval of the Slaughter Lane 90 Acre Tract, Phase 1 Small Lot Final Plat out of an approved Preliminary Plan. The plan is comprised of 123 single family lots, 4 open space/water quality/PUE/drainage/landscape/park easement lots, and approximately 4,448 linear feet of right-of-way/streets. Sidewalks are proposed on all streets. Parkland will be in compliance with City of Austin requirements. Water and wastewater will be provided by the City of Austin. Staff recommends approval of the final plat, subject to the conditions listed in the attached comment report. After the conditions are met, the plan will comply with LDC 30-2-84. The conditions include remove or update notes, update County Clerk’s name, verify lot count, and provide information as required in the report. These are administrative actions that require no discretionary review. An application that has been approved with conditions may be updated to address those conditions until the application expires and the plan does not need to be heard before the Commission again. STAFF RECOMMENDATION: Staff recommends approval of the preliminary plan, subject to the conditions listed in the comment report dated November 30, 2022 and attached as Exhibit C. CASE MANAGER: Paul Scoggins, Travis County Single Office PHONE: 512-854-7619 Email address: Paul.Scoggins@traviscountytx.gov Exhibit A: Slaughter Lane 90 Acre Tract, Phase 1 Small Lot, Final Plat, Exhibit B. Location Map Exhibit C: Slaughter Lane 90 Acre Tract, Phase 1 Small Lot Final Plat Comment Report 1 of 911 2 of 911 CITY OF AUSTIN – TRAVIS COUNTY – SINGLE SUBDIVISION OFFICE SUBDIVISION APPLICATION – MASTER COMMENT REPORT UPDATE: PHONE #: U0 (512)854-7619 C8J-2020-0057.1A 00 Slaughter Ln 90 Ac Tract, Phase One 0-826 E SLAUGHTER LN CASE NUMBER: REVISION #: CASE MANAGER: Paul J. Scoggins PROJECT NAME: LOCATION: SUBMITTAL DATE: November 7, 2022 REPORT DUE DATE: November 28, 2022 FINAL REPORT …

Scraped at: Dec. 2, 2022, 9:55 a.m.
Dec. 6, 2022

12 C8-2019-0146.1A - Thaxton Subdivision, Small Lot Subdivision; District 2.pdf original pdf

Thumbnail of the first page of the PDF
Page 1 of 13 pages

SUBDIVISION REVIEW SHEET CASE NO.: C8-2019-0146.1A COMMISSION DATE: December 6, 2022 SUBDIVISION NAME: Thaxton Subdivision, Small Lot Subdivision, Phase One ADDRESS: E. Slaughter Lane & Thaxton Road (TCAD Parcel: 0339010369) APPLICANT: M/I Homes of Austin, LLC (Royce Rippy) AGENT: LJA Engineering (Russell Kotara, P.E) ZONING: Interim-Annexed 8/8/2022 (single family) NEIGHBORHOOD PLAN: n/a AREA: 56.21 acres (2448507.6 sf) LOTS: 152 COUNTY: Travis DISTRICT: 2 WATERSHED: Marble Creek JURISDICTION: Full Purpose SIDEWALKS: Sidewalks will be constructed along streets. VARIANCE: None DEPARTMENT COMMENTS: The request is for the approval of Thaxton Subdivision, Small Lot Subdivision, Phase One final plat comprised of 152 lots on 56.21 acres (2448507.6 sf). The plat does not comply with the criteria for approval in LDC 25-4-84(B) and staff recommends disapproval for the reasons listed in the attached comment report. An application that has been disapproved with reasons may be updated to address those reasons until the application expires. If the applicant submits an update to address the reasons for disapproval, that update will be presented to the Land Use Commission within fifteen days of submittal. STAFF RECOMMENDATION: Staff recommends disapproval of the final plat for reasons listed in Exhibit C in the support material. CASE MANAGER: Cesar Zavala PHONE: 512-974-3404 E-mail: cesar.zavala@austintexas.gov ATTACHMENTS Exhibit A: Vicinity map Exhibit B: Proposed final plat Exhibit C: Comment Report ` 1 of 1313 2 of 1313 9/29/20229/29/2022C8-2019-0146.1ADETENTION REQUIREMENTS FOR ALL LOTS WITHIN THE THAXTON ROAD PRELIMINARY PLAN (C8J-2019-0146), INCLUDING THE DEVELOPMENT OF BLOCK C LOT 78 WITH 65% OFIMPERVIOUS COVER, WILL BE PROVIDED BY A PROPOSED DETENTION POND(S) IN THIS PHASE.22.3 of 1313 4 of 1313 5 of 1313 C8-2019-0146.1A6 of 1313 CITY OF AUSTIN SUBDIVISION APPLICATION – MASTER COMMENT REPORT U0 512-974-3404 Thaxton Subdivision, Phase One 8617-8924 THAXTON RD C8-2019-0146.1A CASE NUMBER: REVISION #: UPDATE: 00 CASE MANAGER: Cesar Zavala PHONE #: PROJECT NAME: LOCATION: SUBMITTAL DATE: November 7, 2022 REPORT DUE DATE: December 2, 2022 FINAL REPORT DATE: November 30, 2022 STAFF REPORT: This report includes all staff comments received to date concerning your most recent subdivision application submittal. The comments may include requirements, recommendations, or information. The requirements in this report must be addressed by an updated submittal. The subdivision application will be approved when all requirements from each review discipline have been addressed. If you have any questions, concerns or if you require additional information about this report, please contact your case manager at the phone number …

Scraped at: Dec. 2, 2022, 9:55 a.m.
Dec. 6, 2022

14 C8-2022-0267.0A – Research Park Resubdivision of Lot 1-A.pdf original pdf

Thumbnail of the first page of the PDF
Page 1 of 15 pages

SUBDIVISION REVIEW SHEET CASE NO.: C8-2022-0267.0A COMMISSION DATE: December 6, 2022 SUBDIVISION NAME: Resubdivision of Lot 1-A ADDRESS: 11801-1/2 Research Blvd Service Road APPLICANT: Karlin Duval, LLC (Matthew Schwab) AGENT: HRGreen Development TX (Joe Isaja) ZONING: LI, LI-CO (Limited Industrial) NEIGHBORHOOD PLAN: n/a AREA: 35.2 acres (1,533,312 sf) LOTS: 8 COUNTY: Travis DISTRICT: 6 WATERSHED: Walnut Creek JURISDICTION: Full Purpose SIDEWALKS: Sidewalks along state maintained property must be approved by TxDOT. VARIANCE: None DEPARTMENT COMMENTS: The request is for the approval of Resubdivision of Lot 1-A final plat comprised of 8 commercial lots on 35.2 acres (1,533,312 sf). The plat does not comply with the criteria for approval in LDC 25-4-84(B) and staff recommends disapproval for the reasons listed in the attached comment report. An application that has been disapproved with reasons may be updated to address those reasons until the application expires. If the applicant submits an update to address the reasons for disapproval, that update will be presented to the Land Use Commission within fifteen days of submittal. STAFF RECOMMENDATION: Staff recommends disapproval of the final plat for reasons listed in Exhibit C in the support material. CASE MANAGER: Nick Coussoulis PHONE: 512-978-1769 E-mail: nicholas.coussoulis@austintexas.gov ATTACHMENTS Exhibit A: Vicinity map Exhibit B: Proposed final plat Exhibit C: Comment Report ` 1 of 1514 2 of 1514 3 of 1514 4 of 1514 5 of 1514 6 of 1514 CITY OF AUSTIN –DEVELOPMENT SERVICES DEPARTMENT SUBDIVISION APPLICATION – MASTER COMMENT REPORT CASE NUMBER: UPDATE: CASE MANAGER: C8-2022-0267.0A U0 Nicholas Coussoulis Email: Nicholas.Coussoulis@austintexas.gov PROJECT NAME: LOCATION: Resubdivision of Lot 1-A 11801-1/2 RESEARCH BLVD SVRD NB SUBMITTAL DATE: November 14, 2022 FINAL REPORT DATE: December 1, 2022 STAFF REPORT: This report includes all staff comments received to date concerning your most recent subdivision application submittal. The comments may include requirements, recommendations, or information. The requirements in this report must be addressed by an updated submittal. The subdivision application will be approved when all requirements from each review discipline have been addressed. If you have any questions, concerns or if you require additional information about this report, please contact your case manager at the phone number listed above or by using the contact information listed for each reviewer in this report. Any change to the plan/plat shall not cause noncompliance with any applicable code or criteria. In addition, any change to the plat may trigger new comments. UPDATE DEADLINE INFORMATION (LDC 25-4-56; …

Scraped at: Dec. 2, 2022, 9:55 a.m.
Dec. 6, 2022

Zoning and Platting Commission December 6 2022 Agenda.pdf original pdf

Thumbnail of the first page of the PDF
Page 1 of 8 pages

ZONING & PLATTING COMMISSION AGENDA Tuesday, December 6, 2022 The Zoning and Platting Commission will convene at 6:00 PM on Tuesday, December 6, 2022 at Austin City Hall, Council Chambers, Room 1001 301 W. Second Street, Austin, TX. Some members of the Zoning and Platting Commission may be participating by videoconference. The meeting may be viewed online at: http://www.austintexas.gov/page/watch-atxn-live Cesar Acosta Nadia Barrera-Ramirez – Chair Scott Boone Ann Denkler – Parliamentarian Betsy Greenberg David King – Secretary Jolene Kiolbassa – Vice-Chair Hank Smith Lonny Stern Carrie Thompson Roy Woody EXECUTIVE SESSION (No public discussion) The Zoning & Platting Commission will announce it will go into Executive Session, if necessary, pursuant to Chapter 551 of the Texas Government Code, to receive advice from Legal Counsel on matters specifically listed on this agenda. The commission may not conduct a closed meeting without the approval of the city attorney. Private Consultation with Attorney – Section 551.071 PUBLIC COMMUNICATION The first four (4) speakers signed up prior to the speaker registration deadline will each be allowed a three-minute allotment to address their concerns regarding items not posted on the agenda. APPROVAL OF MINUTES 1. Approval of minutes from November 15, 2022. Attorney: Chrissy Mann, 512-974-2179 Commission Liaison: Andrew Rivera, 512-974-6508 PUBLIC HEARINGS 2. Rezoning: Location: C14-2021-0123 - 7900 South Congress; District 2 7809 Peaceful Hill Lane; 7713 and 7715 and Byrdhill Lane; 7604, 7900 & 7900 1/2 South Congress Avenue, South Boggy Creek Watershed Owner/Applicant: Agape Christian Ministries Austin, Inc. (Lawrence A. Wilkerson); RDO Agent: Request: Staff Rec.: Staff: Properties, LLC (Rob & Denise Ormand) Husch Blackwell LLP (Nikelle Meade) DR and NO-CO to GR-MU-V-CO for Tract 1; CS-MU-V-CO for Tract 2, as amended Recommended, with conditions Wendy Rhoades, 512-974-7719, wendy.rhoades@austintexas.gov Housing and Planning Department C14-2022-0135 - 5807 Ross Road; District 2 5807 Ross Road, Dry Creek East Watershed 3. Rezoning: Location: Owner/Applicant: Radhe Investment Group - RIG 11 Series (Ravi Thakkar) Request: Staff Rec.: Staff: DR to SF-6 Recommended Wendy Rhoades, 512-974-7719, wendy.rhoades@austintexas.gov Housing and Planning Department C14-2022-0153 - Sungold; District 7 13704 Ida Ridge Drive, Walnut Creek Watershed 4. Rezoning: Location: Owner/Applicant: SUNGOLD SM LLC (Arjun Demla) Agent: Request: Staff Rec.: Staff: Bennett Consulting (Rodney K. Bennett) IP to GR-MU Recommended Sherri Sirwaitis, 512-974-3057, sherri.sirwaitis@austintexas.gov Housing and Planning Department 5. Site Plan: Location: Staff Rec.: Staff: Owner/Applicant: BSREP III Decker Lane Agent: Request: SP-2021-0095C - Park 290 Logistics Center; District 1 9921 …

Scraped at: Dec. 3, 2022, 12:10 a.m.
Dec. 6, 2022

13 C8-2022-0287 - Three Hills Apartments District 5.pdf original pdf

Thumbnail of the first page of the PDF
Page 1 of None page

Backup

Scraped at: Dec. 3, 2022, 12:10 a.m.
Dec. 6, 2022

16 B VMU Update Presentation.pdf original pdf

Thumbnail of the first page of the PDF
Page 1 of 16 pages

Vertical Mixed-Use (VMU) Update December 6, 2022 Zoning and Platting Commission Overview  VMU Background  VMU Participation Data  VMU-2 Amendments  Questions 2 Vertical Mixed-Use (VMU)  Austin needs 135,000 new housing units by 2025 to keep pace with population growth  The market is not providing adequate housing for low-income and moderate-income people  Affordable housing is not equitably distributed throughout the city  The cost to close the gap in low-income housing in Austin was estimated at over $11 billion in 2017 3 Vertical Mixed-Use (VMU) VMU is a voluntarydensity bonus program designed to generate community benefits through the use of development incentives. Development Incentive Community Benefit  Adopted in 2010 – Included a one-time opt-in/opt-out process for neighborhood associations or neighborhood planning teams  Applicable along 2010 “core transit corridors” – Connects housing and services to transit – May also include other roadways based on original neighborhood opt-in process  Offers development incentives in exchange for community benefits – Improves flexibility for site development – Creates enhanced pedestrian environment – Regulates affordability – Support sustainable development patterns Site Development Flexibility Reduced Parking Requirement No FAR restrictions Additional Allowable Uses Regulated Affordability Heightened design standards Mix of land uses Active ground floor use 4 Our Toolkit • Local Funding • Federal Funding • Density Bonus • Fee Waivers • Regulations • Subsidize Affordable Housing • Incentivize (Affordable) Housing Current Density Bonus Programs • Citywide: – SMART Housing – Affordability Unlocked • Geographically Specific: • Downtown (+ Rainey) Density Bonus • East Riverside Corridor Regulating Plan • North Burnet Gateway Regulating Plan • Transit Oriented Development Regulating Plans • Plaza Saltillo, MLK, North Lamar/Airport • University Neighborhood Overlay • Vertical Mixed-Use (VMU) • Planned Unit Developments (PUD) 6 Key Strategies: • Market Austin’s 10-Year Affordable Housing Goals 135,000 Units in 10 Years Key Strategies: • Federal funding • Local funding Key Strategies: • Federal funding • Local funding • Density Bonus Programs Key Strategies: • Density Bonus Programs • Strike Fund • Other Incentives Key Strategies: • Strike Fund • LDC Revisions VMU Combining District Example Zoning String: CS-MU-V-CO-NP VMU-Zoned Sites Base Zones Description Max Height % of Sites Impervious Cover CS commercial services GR community commercial LO limited office neighborhood commercial general office neighborhood office LR GO NO 60ft 60ft 40ft 40ft 60ft 35ft 95% 90% 70% 80% 80% 60% 67% 18% 5% 5% 3% 1% …

Scraped at: Dec. 3, 2022, 12:10 a.m.
Dec. 6, 2022

16 C ETOD Policy Plan Presentation_ZoningAndPlattingCommission_12.6.2022.pdf original pdf

Thumbnail of the first page of the PDF
Page 1 of 18 pages

Equitable Transit-Oriented Development ETOD Policy Plan Zoning and Platting Commission- December 2022 Purpose of the Plan Provide a comprehensive framework to help the Austin community ensure that future development around the Project Connect transit system supports residents of all incomes and backgrounds, especially those who have been disproportionately burdened by past transportation and land use decisions. ETOD Resolution 20210610-093 • Prioritization of equitable outcomes • Categorization of TODs by tiers using context-sensitive criteria • Anti-displacement strategies • Preservation of existing and creation of affordable housing • Creation of market-rate housing • Compact, connected and transit-supportive • Mix of land uses • Codify community benefits What is ETOD? TOD vs. Equitable TOD Why we are going from this.... To this! 4 The ETOD Team 5 Austin’s ETOD Journey Corridor Bond, ASMP, and Project Connect ETOD Study ETOD POLICY PLAN REGULATION AND IMPLEMENTATION Established corridors of Establishes protypes for TOD Recommendations for focus, mode split goals, that reflect Austin’s vision to planning prioritization, and procured funding for equitably share the benefits typologies, policy tools, high-capacity transit of transit investments for and next steps to project delivery. residents of all income levels, implement ETOD in Austin. to zoning. Could be and backgrounds. Adopt ETOD station area plans and code amendments that may include updates expanded to other geographies in the future. WE ARE HERE 2016 - 2020 2021 - 2022 2022 - 2023 2023 - onward 6 ETOD Study • $1.65 million in Federal Transit Administration (FTA) TOD planning grants • 98 stations across all Project Connect lines 1 2 Quantitative analysis of existing conditions within ½ mile of station areas Qualitative data collection through robust community engagement 7 Dashboard – Existing Conditions Dashboard Home Page Multifamily Inventory Total Jobs by Industry Station Tour Interactive Data : • Population • Displacement Risk • Jobs • Urban Fabric • Real Estate • Mobility s c i m a n y D s c i t s i r e t c a r a h c l a i c o S l a c i s y h P 8 8 Engagement Touchpoints Community Presentation Large format meetings to present project milestones CAC Working Group Briefings Monthly meetings, Ongoing guidance throughout project and major milestones Tabling/Intercept Surveys In-person events to target specific neighborhoods or demographics Focus Groups & One-on-ones Guided discussions with groups to identify vision and needs and to build consensus amongst …

Scraped at: Dec. 3, 2022, 12:10 a.m.
Dec. 6, 2022

05 CORRECT Backup - C8J-2022-0129.1A - Premier Logistics Park Subdivision_Part1.pdf original pdf

Thumbnail of the first page of the PDF
Page 1 of 62 pages

ITEM FOR ENVIRONMENTAL COMMISSION AGENDA COMMISSION MEETING DATE: October 5, 2022 NAME & NUMBER OF PROJECT: NAME OF APPLICANT OR ORGANIZATION: Park 290 Logistic, SP-2021-0095C BSREP III Decker Lane LOCATION: 11653 Decker Lane Austin Tx 78724 COUNCIL DISTRICT: District 1 ENVIRONMENTAL REVIEW STAFF: Enrique A Maiz-Torres, Environmental Review Specialist Senior, DSD, 512-974-3035 WATERSHED: Gilleland Creek/Decker Creek, Suburban, Desired Development Zone REQUEST: Variance request is as follows: -Request to vary from LDC 25-8-342 to allow fill over 4 feet up to 28 feet. -Request to vary from LDC 25-8-341 to allow cut over 4 feet up to 22 feet STAFF RECOMMENDATION: Staff recommends this variance, having determine the finding of fact to have been met. STAFF CONDITION: -Provide a tree-shaded outdoor seating area as to encourage employees to take breaks on-site, rather than driving to alternative locations. -Provide an on-site trail with drainage swales that naturally convey flows into existing on-site ponds. -Provide vegetative walls adjacent to the critical environmental feature located on the site. -Provide terraced landscaping area in the open space allocated on the site. Development Services Department Staff Recommendations Concerning Required Findings Park 290 Logistic (SP-2021-0095C) Watershed Protection Ordinance Project Name: Ordinance Standard: Variance Request: To allow cut over -4 feet up to -22 feet within the Desired Development Zone Include an explanation with each applicable finding of fact. A. Land Use Commission variance determinations from Chapter 25-8-41 of the City Code: 1. The requirement will deprive the applicant of a privilege available to owners of similarly situated property with approximately contemporaneous development subject to similar code requirements. Yes, The variance will not be providing a special privilege to the applicant. The proposed buildings are similar in size to similarly situated property. To facilitate this type of development, significant levelling is required to enhance maneuverability into loading docks, allowing trucks to operated safely on site following FFE standards. The building configuration and placement on the property was based on lot configuration, existing topography, and roadways connectivity. To meet all the above requirements cut and fill limits is necessary to create a level finished- floor elevation and level loading dock and to maintain drives at minimal grades for maneuverability. Therefore, by not allowing this variance would deprive the applicant of a privilege available to owner of similarly situated property. Example: Dalfen Industrial - (SP-2020-0407D), Applied Materials Logistic Service Center- (SP-2020-0321C), Crossroad Logistic Center- (SP-2021- 0015D) 2. The variance: a) …

Scraped at: Dec. 6, 2022, 12:40 a.m.
Dec. 6, 2022

05 CORRECT Backup - C8J-2022-0129.1A - Premier Logistics Park Subdivision_Part2.pdf original pdf

Thumbnail of the first page of the PDF
Page 1 of 2 pages

1 3 8 0 . 5 8 4 . 2 1 5 : T 0 2 3 E T U S I , Y P X E C A P O M . N 1 0 7 8 0 0 0 8 0 0 0 1 - S L M R F G N Y E V R U S I I . G E R X T I 9 6 4 - F M R F G N R E E N G N E I I . G E R X T 9 5 7 8 7 X T , I N T S U A R E T N E C S C I T S I G O L 0 9 2 K R A P E N A L R E K C E D 3 5 6 1 1 S A X E T , Y T N U O C S I V A R T , N I T S U A F O Y T I C C S E 1 E S A H P N O I T C U R T S N O C GENERAL NOTES: IF DISTURBED AREA IS NOT TO BE WORKED ON FOR MORE THAN 14 DAYS, DISTURBED AREA NEEDS TO BE STABILIZED BY REVEGETATION MATTING. [ECM 1.4.4.B.3, SECTION 5,1.] ENVIRONMENTAL INSPECTOR HAS THE AUTHORITY TO ADD AND/OR MODIFY EROSION/SEDIMENTATION CONTROLS ON SITE TO KEEP PROJECT IN-COMPLIANCE WITH THE CITY OF AUSTIN RULES AND REGULATIONS. [LDC 25-8-183] CONTRACTOR SHALL UTILIZE DUST CONTROL MEASURES DURING SITE CONSTRUCTION SUCH AS IRRIGATION TRUCKS AND MULCHING AS PER ECM 1.4.5(A), OR AS DIRECTED BY THE ENVIRONMENTAL INSPECTOR. THE CONTRACTOR WILL CLEAN UP SPOILS THAT MIGRATE ONTO THE ROADS A MINIMUM OF ONCE DAILY.” [ECM 1.4.4.D.4] PROJECT LOCATION TRAVIS COUNTY VICINITY MAP DESIGN DRAWN DATE SHEET NO. 19 SP-2021-0095C 1 3 8 0 . 5 8 4 . 2 1 5 : T 0 2 3 E T U S I , Y P X E C A P O M . N 1 0 7 8 0 0 0 8 0 0 0 1 - S L M R F G N Y E V R U S I I . G E R X T I 9 6 4 - F M R F G N R E E N G N E I I . G …

Scraped at: Dec. 6, 2022, 12:42 a.m.
Dec. 6, 2022

05 Environmental-Commission-Motion.pdf original pdf

Thumbnail of the first page of the PDF
Page 1 of 2 pages

1 ENVIRONMENTAL COMMISSION MOTION 20221005-003 Date: October 5, 2022 Subject: Park 290 Logistic, SP-2021-0095C Motion by: Jennifer Bristol RATIONALE: Seconded by: Kevin Ramberg WHEREAS, the Environmental Commission recognizes the applicant is requesting to vary from LDC 25-8-342 to allow fill over 4 feet up to 28 feet and requesting to vary from LDC 25-8-341 to allow cut over 4 feet up to 22 feet and; WHEREAS, the Environmental Commission recognizes the site is located in the Gilleland Creek Watershed, Suburban, Desired Development Zone; and WHEREAS, the Environmental Commission recognizes that Staff recommends this variance, with conditions having determined the required Findings of Fact have been met. THEREFORE, the Environmental Commission recommends the variance request with the following conditions: Staff Conditions: • Provide a tree-shaded outdoor seating area as to encourage employees to take breaks on-site, rather than driving to alternative locations. • Provide an on-site trail with drainage swales that naturally convey flows into existing on-site ponds. • Provide vegetative walls adjacent to the critical environmental feature located on the site. • Provide terraced landscaping area in the open space allocated on the site. and the following Environmental Commission Conditions: • • • • • • Recommend including solar technology where possible Recommend using A/C condensation catchment system to be used for landscaping Include at least one EV charging station for staff or visitors Encourage long-term tree care plan for the new and existing trees Utilize native plant standards for Blackland Prairie Utilize Dark Sky lighting in outdoor spaces The applicant will work with staff and landscape architect to increase the number of trees on site by 50 additional trees beyond what is on the plan set to the maximum extent practicable per site condition availability. Incorporate plants that support pollinators. The applicant will work with staff to review the reflective glass product they have proposed to ensure it is reducing bird strikes onsite. VOTE 9-0 For: Aguirre, Bedford, Brimer, Bristol, Ramberg, Schiera, Scott, Thompson, and Qureshi Against: None Abstain: None Recuse: None Absent: Barrett Bixler and Nickells Approved By: Kevin Ramberg, Environmental Commission Chair • • • 2

Scraped at: Dec. 6, 2022, 12:45 a.m.
Dec. 6, 2022

02 - Public Communication.pdf original pdf

Thumbnail of the first page of the PDF
Page 1 of 6 pages

From: To: Subject: Date: Wendy, Rhoades, Wendy Peaceful Hill Rezoning Sunday, December 4, 2022 4:40:19 PM *** External Email - Exercise Caution *** I'm writing on behalf of our adjacent neighbors just across South Boggy Creek. When the new apartments were approved at 7400 South Congress just beside my home at 301 Blackberry, we were able to keep the entry and exit to those new buildings channeled out onto South Congress, and avoided having our Blackberry connected as a through street to Congress to provide a rear access. I notice in the case of this new and otherwise similar apartment development just across the creek from us that Foremost is being planned as a through street in the name of "connectivity." It will completely change the existing character of the residential neighborhood if Foremost becomes a connector from Peaceful Hill all the way through to I- 35. Providing denser housing on public transit routes is a worthy goal, but changing the character of an existing neighborhood is a sacrilege, and should be avoided at all costs. The same is true of forcing an existing residential neighborhood to accept the presence of four story apartments towers over the current single story owner occupied private homes. Connectivity and denser housing are worthwhile goals, but not in the context of ruining the quality of life of people who have invested years of their earnings in a quiet and calm existence that will be destroyed by this proposed new group of dense apartments. Peaceful hill should be granted the same right to a deeply wooded set-back and no heavily traveled connector street that was afforded to our neighborhood just to the north of them by a few blocks. Please, be considerate. Thank you. ~Ed Miller CAUTION: This email was received at the City of Austin, from an EXTERNAL source. Please use caution when clicking links or opening attachments. If you believe this to be a malicious and/or phishing email, please forward this email to cybersecurity@austintexas.gov. From: To: Subject: Date: Rhoades, Wendy Peaceful Hill Rezoning Sunday, December 4, 2022 4:45:21 PM *** External Email - Exercise Caution *** Hello Wendy, I'm writing on behalf of our adjacent neighbors just across South Boggy Creek. When the new apartments were approved at 7400 South Congress just beside my home at 301 Blackberry, we were able to keep the entry and exit to those new buildings channeled out …

Scraped at: Dec. 6, 2022, 3:10 p.m.
Nov. 15, 2022

Zoning and Platting Commission November 15 2022 Agenda.pdf original pdf

Thumbnail of the first page of the PDF
Page 1 of 6 pages

ZONING & PLATTING COMMISSION AGENDA Tuesday, November 15, 2022 The Zoning and Platting Commission will convene at 6:00 PM on Tuesday, November 15, 2022 at Austin City Hall, Boards and Commissions, Room 1101 301 W. Second Street, Austin, TX. Some members of the Zoning and Platting Commission may be participating by videoconference. The meeting may be viewed online at: http://www.austintexas.gov/page/watch-atxn-live Cesar Acosta Nadia Barrera-Ramirez – Chair Scott Boone Ann Denkler – Parliamentarian Betsy Greenberg David King – Secretary Jolene Kiolbassa – Vice-Chair Hank Smith Lonny Stern Carrie Thompson Roy Woody EXECUTIVE SESSION (No public discussion) The Zoning & Platting Commission will announce it will go into Executive Session, if necessary, pursuant to Chapter 551 of the Texas Government Code, to receive advice from Legal Counsel on matters specifically listed on this agenda. The commission may not conduct a closed meeting without the approval of the city attorney. Private Consultation with Attorney – Section 551.071 PUBLIC COMMUNICATION The first four (4) speakers signed up prior to the speaker registration deadline will each be allowed a three-minute allotment to address their concerns regarding items not posted on the agenda. APPROVAL OF MINUTES 1. Approval of minutes from November 1, 2022. Attorney: Chrissy Mann, 512-974-2179 Commission Liaison: Andrew Rivera, 512-974-6508 PUBLIC HEARINGS 2. Site Plan: Location: Staff Rec.: Staff: 3. Final Plat from an Approved Preliminary Plan: Owner/Applicant: BSREP III Decker Lane Agent: Request: SP-2021-0095C - Park 290 Logistics Center; District 1 9921 East US 290 Highway Service Road Eastbound, Gilleland Creek / Decker Creek Watersheds Pacheco Koch Consulting Engineers (Hollis Scheffler) Environmental Variance to permit fill over 4 feet up to 28 feet and to permit cut over 4 feet up to 22 feet. Recommended Enrique Maiz-Torres, 512-974-3035, enrique.maiz- torres@austintexas.gov Randall Rouda, 512-974-3338, randall.rouda@austintexas.gov Development Services Department C8J-2022-0129.1A - Premier Logistics Park Subdivision 2900 ½ Ferguson Lane, Walnut Creek Watershed Location: Owner/Applicant: Premier Logistics Park, Inc. (Toby Rogers) Agent: Request: Parnell Engineering Inc. (Will Parnell) Approval with conditions of Premier Logistics Park Subdivision consisting of 7 industrial lots on 148.27 acres. Water and wastewater will be provided by the City of Austin. Approval with Conditions Sarah Sumner, 512-854-7687, sarah.sumner@traviscountytx.gov Single Office Staff Rec.: Staff: 4. Site Plan: Location: Owner/Applicant: Agent: Request: Staff Rec.: Staff: SP-2021-0242C - Loyola Junction Apartments; District 1 6571 Ed Bluestein Blvd, Walnut Creek Watershed 3 S&D Interests Jamison Civil Engineering (Stephen Jamison) Environmental Variance to permit fill over …

Scraped at: Nov. 10, 2022, 3:40 p.m.
Nov. 15, 2022

02 SP-2021-0095C - Park 290 Logistics Center; District 1.pdf original pdf

Thumbnail of the first page of the PDF
Page 1 of 55 pages

June 16, 2022 ENVIRONMENTAL COMMISSION VARIANCE APPLICATION FORM Variance Request Letter Park 290 Logistics Center 11653 Decker Lane City of Austin, TX SP-2021-0095C §25-8-341 Cut Requirements §25-8-342 Fill Requirements March 30, 2022 Denise Lucas, Director Planning and Zoning Department City of Austin P.O. Box 1088 Austin, TX 78767 RE: Dear Ms. Lucas: On behalf of the owners, BSREP III Decker Lane, LP, we are requesting a variance for fill and cut in excess of four (4) feet for the proposed development of the Park 290 Logistics Center development permit (SP-2021-0095C) located at 11653 Decker Lane, City of Austin, TX. The subject project is located within the city limits of Austin. The property is currently undeveloped and is located at the southeast corner of SH 290 and Decker Lane. The applicant plans to develop four new industrial buildings with fire lanes and parking areas, three water quality/detention ponds, utility extensions, offsite trail extension, and landscaping. The applicant proposes to place new improvements on the property in a way to minimize adverse impacts to the natural character of the property. City of Austin | Environmental Commission Variance Application Guide 1 June 16, 2022 The site is not located within the Drinking Water Protection Zone nor the Edwards Aquifer Recharge Zone. The site is in the Onion Creek Watershed of the Colorado River Basin and is classified as a Suburban Watershed by Chapter 25-8 of the City’s Land Development Code. The project requires leniency from the following code section: Division 5. – Cut, Fill, and Spoil § 25-8-341 - CUT REQUIREMENTS. (A)Cuts on a tract of land may not exceed four feet of depth, except: (1) in an urban watershed; (2 )in a roadway right-of-way; (3 )for construction of a building foundation or swimming pool; (4) for construction of a water quality control or detention facility and appurtenances for conveyance such as swales, drainage ditches, and diversion berms, if: (a) the design and location of the facility within the site minimize the amount of cut over four feet; (b) the cut is the minimum necessary for the appropriate functioning of the facility; and (c) the cut is not located on a slope with a gradient of more than 15 percent or within 100 feet of a classified waterway; (5) for utility construction or a wastewater drain field, if the area is restored to natural grade; (6) in a state-permitted sanitary landfill or a …

Scraped at: Nov. 10, 2022, 3:40 p.m.
Nov. 15, 2022

03 C8J-2022-0129.1A - Premier Logistics Park Subdivision.pdf original pdf

Thumbnail of the first page of the PDF
Page 1 of 8 pages

ZAP DATE: 11/15/2022 SUBDIVISION REVIEW SHEET CASE NO.: C8J-2022-0129.1A SUBDIVISION NAME: Premier Logistics Park Subdivision AREA: 148.27 acres OWNER/APPLICANT: Premier Logistics Park, Inc. (Toby Rogers) AGENT: Parnell Engineering Inc. (Will Parnell) ADDRESS OF SUBDIVISION: 2900 ½ Ferguson Lane GRIDS: MN28 WATERSHED: Walnut Creek LOT(S): 7 COUNTY: Travis JURISDICTION: 2-Mile ETJ MUD: N/A EXISTING ZONING: N/A PROPOSED LAND USE: Industrial ADMINISTRATIVE WAIVERS: N/A VARIANCES: None SIDEWALKS: Sidewalks will be provided on all internal streets. DEPARTMENT COMMENTS: The request is for approval with conditions of Premier Logistics Park Subdivision consisting of 7 lots on 148.27 acres. Water and wastewater will be provided by the City of Austin. Staff recommends approval of the plat subject to the conditions listed in the attached comment report. After the conditions are met, the plat will comply with City of Austin Land Development Code, Chapter 30-2-84(B). The conditions include adding plat notes, showing a wetland boundary and adding a street table. These are administrative actions that require no discretionary review. An application that has been approved with conditions may be updated to address those conditions until the application expires and the plat does not need to be heard before the Commission again. STAFF RECOMMENDATION: The staff recommends approval with conditions of this subdivision. This plan meets all applicable County, State and City of Austin LDC requirements. ZONING AND PLATTING COMMISSION ACTION: 1 CASE MANAGER: Sarah Sumner Email address: sarah.sumner@traviscountytx.gov PHONE: 512-854-7687 2 SPRINKLE ROAD (60' R.O.W.) LOT 1 BLOCK A (INDUSTRIAL) RUNDBERG (R.O.W. VARIES) I ) S E R A V . . W O R ( . E N A L N O S U G R E F LOT 7 BLOCK D (INDUSTRIAL) LOT 6 BLOCK D (INDUSTRIAL) PREMIER LOGISTICS DRIVE (64' R.O.W.) LOT 5 BLOCK C (INDUSTRIAL) LOT 2 BLOCK B (INDUSTRIAL) MCCLAIN DRIVE (64' R.O.W.) ) . . W O R . ' I 4 6 ( E V R D L L E N R A P LOT 4 BLOCK C (INDUSTRIAL) LOT 3 BLOCK C (INDUSTRIAL) SHEET LAYOUT 1) OVERALL BOUNDARY 2) DETAIL WEST 3) DETAIL CENTRAL 4) DETAIL EAST 5) NOTES PREMIER LOGISTICS PARK SUBDIVISION Travis County, Texas A Limited Liability Company PO Box 90876, Austin Texas 78709 WWW.4WARDLS.COM (512) 537-2384 TBPLS FIRM #10174300 E T A M I X O R P P A N O I T A C O L E N I L Y E V …

Scraped at: Nov. 10, 2022, 3:44 p.m.
Nov. 15, 2022

03 Exhibit C - Comment Report.pdf original pdf

Thumbnail of the first page of the PDF
Page 1 of 6 pages

CITY OF AUSTIN – TRAVIS COUNTY – SINGLE SUBDIVISION OFFICE SUBDIVISION APPLICATION – MASTER COMMENT REPORT UPDATE: PHONE #: U0 512-854-7687 C8J-2019-0186.1A 00 Premier Logistics Park 2900-1/2 FERGUSON LN CASE NUMBER: REVISION #: CASE MANAGER: Sarah Sumner PROJECT NAME: LOCATION: SUBMITTAL DATE: October 17, 2022 REPORT DUE DATE: November 7, 2022 FINAL REPORT DATE: November 10, 2022 STAFF REPORT: 3 DAYS HAVE BEEN ADDED TO THE UPDATE DEADLINE This report includes all staff comments received to date concerning your most recent subdivision application submittal. The comments may include requirements, recommendations, or information. The requirements in this report must be addressed by an updated submittal. The subdivision application will be approved when all requirements from each review discipline have been addressed. However, until this happens, your application is considered disapproved. Additional comments may be generated as a result of information or design changes provided in your update. If you have any questions, problems, concerns, or if you require additional information about this report, please do not hesitate to contact your case manager at the phone number listed above or by writing to the City of Austin, Development Services Department, P.O. Box 1088, Austin, Texas 78767. UPDATE DEADLINE (LDC 30-2-56; 30-2-82): It is the responsibility of the applicant or their agent to update this subdivision application. Formal submittal Oct. 17, LUC Nov. 15, End of Formal 1/15/2023, Fiscal by 4/15/23, Recording by 7/14/23. The final update to clear all comments must be submitted by the update deadline, which is January 16, 2023. Otherwise, the application will automatically be denied. If this date falls on a weekend or City of Austin holiday, the next City of Austin workday will be the deadline. EXTENSION OF UPDATE DEADLINE (LDC 30-1-119): You may request an extension to the update deadline by submitting a written justification to your case manager on or before the update deadline. Extensions may be granted for good cause at the Director’s discretion. UPDATE SUBMITTALS: An informal update submittal is required. Please coordinate directly with each reviewer listed below to clear comments. Electric Review - Andrea Katz - 512-322-6957 REVIEWERS: Planner 1: Chima Onyia Approved 911 Addressing Review - Janny Phung - janny.phung@austintexas.gov AD1: This plat review is rejected for the following reasons: AD2: RUNDBERG is a continuation of TUSCANY WAY and must continue the same name. It also does is an active street name and does not have a street type is …

Scraped at: Nov. 10, 2022, 3:44 p.m.
Nov. 15, 2022

04 SP-2021-0242C - Loyola Junction Apartments; District 1.pdf original pdf

Thumbnail of the first page of the PDF
Page 1 of 68 pages

SITE PLAN REVIEW SHEET ENVIRONMENTAL VARIANCE REQUEST ONLY CASE: SP-2021-0242C ZONING AND PLATTING COMMISSION DATE: November 15, 2022 PROJECT NAME: Loyola Junction Apartments APPLICANT: 3 S&D Interests AGENT: Stephen Jamison, Jamison Civil Engineering ADDRESS OF SITE: 6571 Ed Bluestein Blvd COUNTY: Travis WATERSHED: Walnut Creek, Suburban, DDZ JURISDICTION: Full purpose EXISTING ZONING: GR-MU and CS-MU-C) PROPOSED DEVELOPMENT: The applicant is proposing to construct an apartment complex with related amenities. DESCRIPTION OF VARIANCES: The applicant is requesting to vary from LDC 25-8-342 to allow fill over four feet to 17 feet within the desired development zone. STAFF RECOMMENDATION: The findings of fact have been met, and staff recommends approval for fill to 17 feet, with the following conditions: AREA: 14.46 acres Install a retaining wall to contain the major fill areas o o Utilize terracing techniques in the areas of major fill o o Add additional COA 609S Native seeding at the bottom of the major fill areas Increase the CEF setback for the existing CEF wetland feature in the area by 50 feet ENVIRONMENTAL BOARD ACTION: October 19, 2022: With a 9-0 vote, the Environmental Commission recommends support of the request, with staff conditions for a variance from LDC 25-8-342 to allow fill over four feet to 17 feet. ENVIRONMENTAL REVIEW STAFF: Mel Fuechec PHONE: 974-3036 mel.fuechec@austintexas.gov CASE MANAGER: Christine Barton-Holmes christine.barton-holmes@austintexas.gov PHONE: 974-2788 ITEM FOR ENVIRONMENTAL COMMISSION AGENDA COMMISSION MEETING DATE: 11/2/22 NAME & NUMBER OF PROJECT: Loyola Junction Apartments SP-2021-0242C NAME OF APPLICANT OR ORGANIZATION: STEPHEN JAMISON Jamison Civil Engineering LOCATION: 6525 ED BLUESTEIN BOULEVARD NB AUSTIN, Texas, 78724 COUNCIL DISTRICT: District #1 ENVIRONMENTAL REVIEW STAFF: Mel Fuechec, Environmental Review Specialist, Sr, DSD, 512- 974-3036, mel.fuechec@austintexas.gov WATERSHED: Walnut Creek, Suburban Watershed, Desired Development Zone REQUEST: Variance request is as follows: Request to vary from LDC 25-8-342 to allow fill up to 17 feet in the desired development zone. STAFF RECOMMENDATION: Staff recommends this variance, having determined the findings of fact to have been met. STAFF CONDITION: • • Install a retaining wall to contain the major fill areas • Utilize terracing techniques in the areas of major fill Increase the CEF setback for the existing CEF wetland feature in the area by 50 feet • Add additional COA 609S Native seeding at the bottom of the major fill areas Development Services Department Staff Recommendations Concerning Required Findings Project Name: Ordinance Standard: Watershed Protection Ordinance Variance Request: Loyola Junction …

Scraped at: Nov. 10, 2022, 3:44 p.m.
Nov. 15, 2022

05 C8-2022-0257.0A - Regiene Subdivision; District 1.pdf original pdf

Thumbnail of the first page of the PDF
Page 1 of 15 pages

SUBDIVISION REVIEW SHEET CASE NO.: C8-2022-0257.0A COMMISSION DATE: November 15, 2022 SUBDIVISION NAME: Regiene Subdivision ADDRESS: 6501 Regiene Road APPLICANT/AGENT: Rita Wersich (WGI) ZONING: LI-PDA-NP/LI-CO-NP NEIGHBORHOOD PLAN: MLK -183 AREA: 20 acres (878,354 sf) LOTS: 9 COUNTY: Travis DISTRICT: 1 WATERSHED: Boggy Creek JURISDICTION: Full Purpose VARIANCE: None DEPARTMENT COMMENTS: The request is for Final Plat approval for 6 commercial/office/retail lots, 2 multifamily lots, and 1 greenspace lot on 20 acres (878,354 sf). Staff recommends approval of the plat, subject to the conditions listed in the attached comment report. After the conditions are met, the plat will comply with LDC 25-4-84(B). The conditions include a couple of plats notes; continue discussions with PARD regarding construction and timing of trail easement; and making 911 addressing corrections on the plat. These are administrative actions that require no discretionary review. An application that has been approved with conditions may be updated to address those conditions until the application expires and the plat does not need to be heard before the Commission again. STAFF RECOMMENDATION: Staff recommends approval of the plat, subject to the conditions listed in the master comment report dated November 9, 2022, and attached as Exhibit C. CASE MANAGER: Juan Enriquez, Senior Planner PHONE: 512-974-2767 E-mail: juan.enriquez@austintexas.gov ATTACHMENTS Exhibit A: Vicinity Map Exhibit B: Proposed Final Plat Exhibit C: Comment Report Dated November 9, 2022 N L L HIL E N N A T H AR OLD CT HUDSON ST D TS R ET B HIB D SB B D N ED BLUESTEIN BLV ED BLUESTEIN BLV R E G I E N E R D SUBJECT SITE +/- 20.16 acres D E L WA U L N BAY CITY BND Site Location Map Regiene Development Site 6705 Regiene Road Austin, Travis County, Texas 78704 SHELTON RD Legend 0 125 250 500 Feet 30205951.00 | 07.21.2022 | WGINC.COM SLM I [D] LOT 1 BLOCK A [A] [E] SEE ENLARGED PLAN ON SHEET 2 LOT 2A RESUBDIVISION OF LOT 1 MOTOROLA INC. ED BLUESTEIN FACILITY DOC. NO. 200600304 O.P.R.T.C.T. LOT 1A-B RESUBDIVISION PLAT OF LOT 1A, RESUBDIVISION PLAT OF LOT 1, MOTOROLA INC. ED BLUESTEIN FACILITY DOC. NO. 200900045 O.P.R.T.C.T. ZEN GARDEN COMMERCIAL CONDOMINIUM DOC. NO. 2019032883 O.P.R.T.C.T. [F] R E G I E N E R O A D ( R . O . W . V A R I E S ) LOT 5 BLOCK A [M] [N] LOT 3 …

Scraped at: Nov. 10, 2022, 3:49 p.m.
Nov. 15, 2022

02 Enviromental-Commission-Motion.pdf original pdf

Thumbnail of the first page of the PDF
Page 1 of 2 pages

1 ENVIRONMENTAL COMMISSION MOTION 20221005-003 Date: October 5, 2022 Subject: Park 290 Logistic, SP-2021-0095C Motion by: Jennifer Bristol RATIONALE: Seconded by: Kevin Ramberg WHEREAS, the Environmental Commission recognizes the applicant is requesting to vary from LDC 25-8-342 to allow fill over 4 feet up to 28 feet and requesting to vary from LDC 25-8-341 to allow cut over 4 feet up to 22 feet and; WHEREAS, the Environmental Commission recognizes the site is located in the Gilleland Creek Watershed, Suburban, Desired Development Zone; and WHEREAS, the Environmental Commission recognizes that Staff recommends this variance, with conditions having determined the required Findings of Fact have been met. THEREFORE, the Environmental Commission recommends the variance request with the following conditions: Staff Conditions: • Provide a tree-shaded outdoor seating area as to encourage employees to take breaks on-site, rather than driving to alternative locations. • Provide an on-site trail with drainage swales that naturally convey flows into existing on-site ponds. • Provide vegetative walls adjacent to the critical environmental feature located on the site. • Provide terraced landscaping area in the open space allocated on the site. and the following Environmental Commission Conditions: • • • • • • Recommend including solar technology where possible Recommend using A/C condensation catchment system to be used for landscaping Include at least one EV charging station for staff or visitors Encourage long-term tree care plan for the new and existing trees Utilize native plant standards for Blackland Prairie Utilize Dark Sky lighting in outdoor spaces The applicant will work with staff and landscape architect to increase the number of trees on site by 50 additional trees beyond what is on the plan set to the maximum extent practicable per site condition availability. Incorporate plants that support pollinators. The applicant will work with staff to review the reflective glass product they have proposed to ensure it is reducing bird strikes onsite. VOTE 9-0 For: Aguirre, Bedford, Brimer, Bristol, Ramberg, Schiera, Scott, Thompson, and Qureshi Against: None Abstain: None Recuse: None Absent: Barrett Bixler and Nickells Approved By: Kevin Ramberg, Environmental Commission Chair • • • 2

Scraped at: Nov. 14, 2022, 9:10 p.m.
Nov. 15, 2022

02 Enviromental-Commission-Motion.pdf original pdf

Thumbnail of the first page of the PDF
Page 1 of 2 pages

1 ENVIRONMENTAL COMMISSION MOTION 20221005-003 Date: October 5, 2022 Subject: Park 290 Logistic, SP-2021-0095C Motion by: Jennifer Bristol RATIONALE: Seconded by: Kevin Ramberg WHEREAS, the Environmental Commission recognizes the applicant is requesting to vary from LDC 25-8-342 to allow fill over 4 feet up to 28 feet and requesting to vary from LDC 25-8-341 to allow cut over 4 feet up to 22 feet and; WHEREAS, the Environmental Commission recognizes the site is located in the Gilleland Creek Watershed, Suburban, Desired Development Zone; and WHEREAS, the Environmental Commission recognizes that Staff recommends this variance, with conditions having determined the required Findings of Fact have been met. THEREFORE, the Environmental Commission recommends the variance request with the following conditions: Staff Conditions: • Provide a tree-shaded outdoor seating area as to encourage employees to take breaks on-site, rather than driving to alternative locations. • Provide an on-site trail with drainage swales that naturally convey flows into existing on-site ponds. • Provide vegetative walls adjacent to the critical environmental feature located on the site. • Provide terraced landscaping area in the open space allocated on the site. and the following Environmental Commission Conditions: • • • • • • Recommend including solar technology where possible Recommend using A/C condensation catchment system to be used for landscaping Include at least one EV charging station for staff or visitors Encourage long-term tree care plan for the new and existing trees Utilize native plant standards for Blackland Prairie Utilize Dark Sky lighting in outdoor spaces The applicant will work with staff and landscape architect to increase the number of trees on site by 50 additional trees beyond what is on the plan set to the maximum extent practicable per site condition availability. Incorporate plants that support pollinators. The applicant will work with staff to review the reflective glass product they have proposed to ensure it is reducing bird strikes onsite. VOTE 9-0 For: Aguirre, Bedford, Brimer, Bristol, Ramberg, Schiera, Scott, Thompson, and Qureshi Against: None Abstain: None Recuse: None Absent: Barrett Bixler and Nickells Approved By: Kevin Ramberg, Environmental Commission Chair • • • 2

Scraped at: Nov. 14, 2022, 9:10 p.m.