Historic Landmark Commission Homepage

RSS feed for this page

Jan. 10, 2024

14.1 - 100% Struct CD_402 Lockhart_10 20 23 original pdf

Thumbnail of the first page of the PDF
Page 1 of 8 pages

D GENERAL NOTES: APPLICABLE CODES: LOADS (ASD): -BUILDING CATEGORY II -WIND VELOCITY 115 MPH -EXPOSURE CATEGORY C -ROOF LIVE LOAD 20 PSF -ATTIC LIVE LOAD 20 PSF -FLOOR LIVE LOAD 40 PSF -DEAD LOAD 15 PSF 1 2 3 4 5 STRUCTURAL FOUNDATION PLANS, BRACED PLANS, FRAMING PLANS AND DETAILS FOR REMODEL/ADDITION C -AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) STEEL CONSTRUCTION MANUAL 14TH EDITION -INTERNATIONAL BUILDING CODE (IBC) 2021 -INTERNATIONAL RESIDENTIAL CODE (IRC) 2021 -ASCE 07-16 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES -NDS 2015 DESIGN OF WOOD STRUCTURES -ACI 318-19: BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE COORDINATION: 402 LOCKHART DR. AUSTIN, TEXAS 78754 1. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING CONSTRUCTION DUTIES & DESIGN INTENT WITHIN THE SUBCONTRACTORS & PROFESSIONAL DISCIPLINES. ANY CONFLICTS ARE TO BE BROUGHT TO THE AOR/EOR BEFORE WORK IS TO BEGIN. THE GENERAL CONTRACTOR IS THEREFORE RESPONSIBLE FOR ALL COSTS OR CORRECTIONS ASSOCIATED WITH THE CONTRACTOR'S FAILURE TO PROPERLY COORDINATE THE CONTSTRUCTION DUTIES & DESIGN INTENT. 2. THE CONTRACTOR SHALL NOTIFY THE EOR/AOR OF ANY SUBSTITUTIONS OR IF CONDITIONS VARY FROM THE ASSUMED CONTRACT DRAWINGS. MODIFICATIONS TO THE STRUCUTRE, DUE TO THE CONTRACTOR DEVIATING FROM THE PLANS, IS NOT THE RESPONSIBLITY OF THE EOR/AOR. 3. REQUESTS FOR SUBSTITUTIONS SHALL BE SUBMITTED TO THE EOR/AOR FOR APPROVAL. SUBSTITUTIONS SHALL NOT BE PERMITTED TO BE USED WITHOUT CONSENT FROM THE EOR/AOR. 4. EXISTING CONDITIONS AND SIZES ARE TO BE VERIFIED BY THE CONTRACTOR. EOR/AOR SHALL NOT ASSUME RESPONSIBLITY FOR INCORRECT MEMBER SIZES/ MATERIAL ORDERS. 5. SOME ITEMS ON THE CONTRACT DOCUMENTS ARE ASSUMED, DUE TO ITEMS NOT BEING ACCESIBLE, HIDDEN, OR UNDISCLOSED AT THE TIME OF CONTRACT DOCUMENT COMPLETION & DELIVERY. IN SUCH CASE NOTIFY THE EOR/AOR WITH A REQUEST FOR INFORMATION AND GUIDANCE AND DETAILING WILL BE PROVIDED BY THE EOR/AOR. PROCEED WITHOUT CONSENT FROM THE EOR/AOR. ABBREVIATIONS LIST: 6. GEO-TECHNICAL REPORT NOT PROVIDED, GC TO VERIFY SOILS CONDITIONS MEET OR EXCEED ASSUMPTIONS. WHERE VOIDS, EXCESSIVE DEBRIS, OR LOOSE MATERIALS ARE ENCOUTERED, A GEO-TECHNICAL ENGINEER SHOULD BE EMPLOYED TO DETERMINE SOLUTION. EOR NOT RESPONSIBLE FOR ISSUES WITH FOUNDATIONS, WHERE CONDITIONS ARE NOT VERIFIED. WHERE OWNER DECLINES GEO-TECHNICAL REPORT, OWNER AT RISK. SHEET INDEX: S-001 GENERAL NOTES & SHEET INDEX S-002 FOUNDATION DETAILS S-003 FRAMING DETAILS S-004 FRAMING DETAILS & ATTACHMENT SCHED. S-101 FOUNDATION PLAN & 1ST FL. BRACED FOUNDATION PLAN S-111 BRACED 2ND FLOOR & 1ST FLOOR FRAMING PLAN S-121 2ND FL. ATTIC & …

Scraped at: Jan. 13, 2024, 2:11 a.m.
Jan. 10, 2024

14.2 - 402 Lockhart ARCH 10-18-2023 -signed-sealed-10-19-2023 original pdf

Thumbnail of the first page of the PDF
Page 1 of None page

Backup

Scraped at: Jan. 13, 2024, 2:12 a.m.
Jan. 10, 2024

14.3 - 402 Lockhart LSD original pdf

Thumbnail of the first page of the PDF
Page 1 of 2 pages

Backup

Scraped at: Jan. 13, 2024, 2:12 a.m.
Jan. 10, 2024

14.4 - 402 Lockhart NSEW pics original pdf

Thumbnail of the first page of the PDF
Page 1 of 4 pages

Backup

Scraped at: Jan. 13, 2024, 2:12 a.m.
Jan. 10, 2024

14.5 - 402 Lockhart Site plan original pdf

Thumbnail of the first page of the PDF
Page 1 of 1 page

Backup

Scraped at: Jan. 13, 2024, 2:12 a.m.
Jan. 10, 2024

14.6 - 402 Lockhart Plan Set original pdf

Thumbnail of the first page of the PDF
Page 1 of None page

Backup

Scraped at: Jan. 13, 2024, 2:12 a.m.
Jan. 10, 2024

14.a - 402 Lockhart Dr - public comment original pdf

Thumbnail of the first page of the PDF
Page 1 of 1 page

Backup

Scraped at: Jan. 13, 2024, 2:12 a.m.
Jan. 10, 2024

14.b - 402 Lockhart Dr - public comment original pdf

Thumbnail of the first page of the PDF
Page 1 of 1 page

From: To: Subject: Date: Luke Allen HPD Preservation Case GF 23-147732 - 403 Lockhart Dr Sunday, December 10, 2023 6:00:47 PM You don't often get email from . Learn why this is important External Email - Exercise Caution Just got the notice about this -- as a neighbor (at favor of letting the homeowner do demolition. (Seems to me like a pretty big overreach to call all random houses in this area historical landmarks -- it's none of my business what he wants to do with his property.) I'd like to register that I'm in Thanks, Luke Allen CAUTION: This is an EXTERNAL email. Please use caution when clicking links or opening attachments. If you believe this to be a malicious or phishing email, please report it using the "Report Message" button in Outlook or forward to cybersecurity@austintexas.gov.

Scraped at: Jan. 13, 2024, 2:12 a.m.
Jan. 10, 2024

15.0 - 1409 Alta Vista Ave original pdf

Thumbnail of the first page of the PDF
Page 1 of 8 pages

20 – 1 HISTORIC LANDMARK COMMISSION PERMITS IN NATIONAL REGISTER HISTORIC DISTRICTS DECEMBER 13, 2023 HR-2023-043027 TRAVIS HEIGHTS-FAIRVIEW PARK NATIONAL REGISTER HISTORIC DISTRICT 1409 ALTA VISTA AVENUE PROPOSAL ARCHITECTURE RESEARCH Construct a second-floor addition, deck, and patio at a ca. 1926 house. PROJECT SPECIFICATIONS The proposed addition is two stories in height. It is clad in horizontal siding, which will be installed throughout. Its roofline mirrors that of the original house, with a clipped side gable and central gablet. Windows are 1:1 throughout, and doors are fully-glazed sliders at secondary elevations. The north elevation features a second-floor balcony with a covered patio below. One-story Craftsman with horizontal wood siding, screened wood windows, decorative shutters, a hooded entryway with decorative brackets, and a clipped-gable roof. The house at 1409 Alta Vista Avenue was built around 1926. Until 1947, its occupants were mostly short-term owners and renters, including an engineer, a state highway inspector, an office manager, and a mechanic. The home was then purchased by Frank and Lura Connolly. Frank Connolly was the editor, owner, and publisher of the Texas Tax Journal, while Lura worked both at the journal and as a Red Cross nurse. The Connollys sold the home in the late 1950s to Anna and William Duncum. William Duncum worked as a public school teacher. DESIGN STANDARDS The City of Austin’s Historic Design Standards (March 2021) are based on the Secretary of the Interior’s Standards for Rehabilitation and are used to evaluate projects in National Register districts. The following standards apply to the proposed project: Repair and alterations 1. General standards The proposed project removes some windows at secondary façades to accommodate the addition. It replaces existing siding with fiber cement siding. Residential additions 1. Location The proposed addition is located at the rear and side of the existing house, set approximately 17’ back from the front wall. 2. Scale, massing, and height The proposed addition appears mostly compatible in scale and massing, though a single story would be more compatible. 3. Design and style The proposed addition’s design and style are largely compatible. 4. Roofs The proposed roof form and materials are compatible. 5. Exterior walls The proposed siding is compatible; however, variations in siding could be used to differentiate original parts of the building from the new parts. 6. Windows, screens, and doors Proposed fenestration appears compatible. 7. Porches and decks Though the porch at the north …

Scraped at: Jan. 13, 2024, 2:12 a.m.
Jan. 10, 2024

15.1 - 1409 Alta Vista Ave - drawings original pdf

Thumbnail of the first page of the PDF
Page 1 of 12 pages

S INGL E ST OR Y R ES IDENCE, A DJA CENT PROPERT Y . EST IMA T ED SIZE A ND P L A C E ME NT R 1'-3" (TREE 2 - LIVE OAK) R 1'-3" (TREE 2 - LIVE OAK) R 7'-6"(1/4 CRZ) R 15'(1/2 CRZ) R 30'(CRZ) R 101/2" (TREE 3 - LIVE OAK) R 5'-3"(1/4 CRZ) R 10'-6"(1/2 CRZ) R 21'(CRZ) A003 1 140.09' P R OP ER T Y L INE 5 FT S ET BA CK R 1'-3" (TREE 1 - LIVE OAK) R 7' R 14' R 28' E N I L Y T R E P O R P 5 37 5 3 8 CO E U N E V A A T S I V A T L A 3 0 0 A 3 K L A W E D I S ' 6 7 . 9 4 WM K C A B T E S T F 5 2 C O NC R E T E W A L K GM E N I L D L I U B T F 5 9 . 9 2 O I T A P E T E R C N O C EM 5 FT S ET BA CK P R OP ER T Y L INE S INGL E ST OR Y R ES ID ENC E T O BE E NL A R G E D 54 4 5 4 7 140.07' 2 A003 5 3 9 54 0 54 1 54 2 54 3 54 5 54 6 54 8 54 9 5 5 0 551 5 5 2 R 1' (TREE 5 - LIVE OAK) R 6'(1/4 CRZ) R 12'(1/2 CRZ) R 24'(CRZ) D E H C A T E D E G A R A G N I A M E R O T K C A B T E S T F 0 1 4 3 0 0 A E T E R C N O C N I A M E R O T E N I L Y T R E P O R P ' 8 1 . 0 5 Y E L L A S E W E R L INE W A T ER SUPPL Y L INE GA S SUPPL Y L INE OV ER HEA D P OW ER L INES T REE P R OT ECT ION …

Scraped at: Jan. 13, 2024, 2:12 a.m.
Jan. 10, 2024

16.0 - 514 E Live Oak St original pdf

Thumbnail of the first page of the PDF
Page 1 of 7 pages

23 – 1 HISTORIC LANDMARK COMMISSION PERMITS IN NATIONAL REGISTER HISTORIC DISTRICTS DECEMBER 13, 2023 HR-2023-118825 TRAVIS HEIGHTS-FAIRVIEW PARK HISTORIC DISTRICT 514 EAST LIVE OAK STREET PROPOSAL ARCHITECTURE RESEARCH Demolish a house constructed between 1917 and 1930 and construct a new building. PROJECT SPECIFICATIONS The proposed new building is two and one-half stories in height. It is clad in stucco, horizontal siding, and brick veneer. Its compound roof is clad in standing-seam metal. Fenestration includes fixed and casement windows with various lite configurations, a partially glazed front door, and a front-facing garage. One-story bungalow with pyramidal hipped roof with intersecting porch gable; partial width inset porch; and horizontal siding. Decorative details include exposed rafter tails and remnants of jigsawn brackets. The house at 514 East Live Oak Street, addressed as both 400 East Live Oak and 2119 Brooklyn in archival documents, is identified in the National Register inventory as a 1917 structure. Though the building does not appear in City directories until the 1930s, its modified form and details suggest an earlier build than the 1930 water tap permit. The Plumley family are the earliest documented residents; they appear to have sold the house in the early 1930s after being caught storing liquor illegally at the house. In the late 1930s into the 1940s, the home was occupied by J. Buford Smith, a bookkeeper at the State Highway Department, and his wife, Katherine. In the 1950s, the house appears to have been primarily a rental property, with residents including a mill operator and a dry cleaner. DESIGN STANDARDS The City of Austin’s Historic Design Standards (March 2021) are based on the Secretary of the Interior’s Standards for Rehabilitation and are used to evaluate projects in National Register districts. The following standards apply to the proposed project: Residential new construction 1. Location The proposed house is set back approximately 15’, per average setback on the block. 2. Orientation The proposed building is oriented toward the primary streetscape, with a front-facing garage that does not meet the standards. 3. Scale, massing, and height The proposed building’s scale, massing, and height all appear much larger and more monolithic than the surrounding buildings, though the changes in mass heights and other wall-plane offsets appear to mitigate some of the incompatibility. 4. Proportions The proposed building’s proportions do not appear to reflect the contributing properties’ proportions, except for the porch. 5. Design and style The …

Scraped at: Jan. 13, 2024, 2:13 a.m.
Jan. 10, 2024

16.1 - 514 E Live Oak St - Revisions original pdf

Thumbnail of the first page of the PDF
Page 1 of 7 pages

9' - 6" 20' - 1" 10' - 4" 8' - 4 1/2" 15' - 4 1/2" 9' - 9 1/2" 5' - 10 1/2" 14' - 2 1/2" 10' - 4" 4' - 2 1/2" 4' - 2 1/2" 7' - 4 1/2" 8' - 0" - --- OVERHANG ABOVE LEVEL 2 ABOVE . 0 1 3 A 2 DN - --- PATIO 303 SF POWDER A5.20 4 S E V L E H S FLEX AREA 4' - 4 1/2" 3' - 5 1/2" 2' - 0" A5.20 1 0' - 0" 4' - 11" 4' - 11" FOYER " 0 - ' 0 8' - 8" " 8 " 7 - ' 2 CLOSET 4' - 2" 3' - 10 1/2" - --- HALLWAY Washer Dryer . T H C - --- CABINETS BELOW W.H. 2' - 9" MUD ROOM 0' - 0" 6' - 1 1/2" 3 A5.20 6 2' - 0 1/2" 5 DW UP " 0 1 3 " 2 / 1 2 - ' 6 " 4 - ' 1 " 7 - ' 2 " 2 / 1 0 - ' 2 4 A5.10 2 1 KITCHEN/DINING " 2 / 1 5 - ' 8 Range LEVEL 2 ABOVE " 2 - ' 4 " 2 / 1 3 - ' 0 1 " 2 / 1 2 - ' 4 1 " 2 / 1 7 - ' 8 2 " 6 " 6 - ' 9 " 1 - ' 7 E V O B A G N A H R E V O A2.20 A2-0 2 1 " 1 1 - ' 1 1 1 A3.10 - --- " 2 / 1 0 - ' 4 " 2 / 1 7 - ' 2 " 4 - ' 2 " 2 / 1 5 - ' 1 " 0 1 - ' 1 " 6 - ' 1 " 2 / 1 1 - ' 2 " 2 / 1 6 - ' 4 1/4" / 1'-0" GARAGE - --- -0' - 4" OVERHANG ABOVE - --- 1' - 10 1/2" 5' - 8" 5' - 1" 4' - 4" 8' - 8" 4' - 4" 7' - 6" 7' - 10 1/2" 20' - 2 1/2" 10' - 9" 17' - 4" 15' - 4 1/2" 15' - 10" 0' - 0" LIVING ROOM - --- 1 2 …

Scraped at: Jan. 13, 2024, 2:13 a.m.
Jan. 10, 2024

16.2 - 514 E Live Oak - Additional Backup original pdf

Thumbnail of the first page of the PDF
Page 1 of 4 pages

MTL01, METAL STANDING SEAM ROOF WD01, VERTICAL WOOD PLANK SIDING 1 North Elevation 1/4" = 1'-0" MTL01, METAL STANDING SEAM ROOF WD01, HORIZONTAL WOOD PLANK SIDING " 2 / 1 0 1 - ' 7 2 ST01, LIGHT GREY STUCCO ST01, LIGHT GREY STUCCO " 2 / 1 0 1 - ' 7 2 EXISTING GRADE 2 South Elevation 1/4" = 1'-0" BR01, GREY BRICK CLADDING ROOF RIDGE 27' - 10 1/2" T.O.P LVL2 19' - 7" T.O.D LVL 2 10' - 7" T.O.P LVL 1 9' - 0" EXISTING GRADE LVL 1 AT 546'-9" 0' - 0" AVERAGE GRADE AT 546.5' WD01, HORIZONTAL WOOD PLANK SIDING ROOF RIDGE 27' - 10 1/2" T.O.P LVL2 19' - 7" T.O.D LVL 2 10' - 7" T.O.P LVL 1 9' - 0" LVL 1 AT 546'-9" 0' - 0" AVERAGE GRADE AT 546.5' SCALE: 1/4" = 1'-0" ( Scale will be half-sized when printed at 11x17 ) LAND STRATEGIES INC. 1983 − 2023 40 YEARS OF EXCELLENCE 1411 W 5th St., #100, Austin, TX 78703 PH: (512) 328−6050 FAX: (512) 328−6172 EMAIL: LSI@LSIaustin.com WEBSITE: LSIaustin.com MICHAEL LINEHAN TEXAS ARCHITECT REGISTRATION # 26973 THIS DOCUMENT IS INCOMPLETE AND MAY NOT BE USED FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION K A O E V I L E 4 1 5 4 0 7 8 7 X T , I N T S U A , T S K A O E V I L E 4 1 5 4 4 1 2 # t c e o r P # j : I S L SET ISSUED 09/06/2023 REVISIONS e t a D n o i t p i r c s e D a t l e D e u s s I DRAWN BY LSI SHEET NAME EXTERIOR ELEVATIONS SHEET A2.10 MTL01, METAL STANDING SEAM ROOF WD01, HORIZONTAL WOOD PLANK SIDING ST01, LIGHT GREY STUCCO 1 East Elevation 1/4" = 1'-0" MTL01, METAL STANDING SEAM ROOF WD01, HORIZONTAL WOOD PLANK SIDING " 2 / 1 0 1 - ' 7 2 BR01, GREY BRICK CLADDING AVERAGE GRADE AT 546.5' 2 West Elevation 1/4" = 1'-0" " 2 / 1 0 1 - ' 7 2 ROOF RIDGE 27' - 10 1/2" BR01, GREY BRICK CLADDING T.O.P LVL2 19' - 7" T.O.D LVL 2 10' - 7" T.O.P LVL 1 9' - 0" LVL 1 AT 546'-9" 0' - 0" AVERAGE GRADE AT …

Scraped at: Jan. 13, 2024, 2:13 a.m.
Jan. 10, 2024

16.3 - 514 E Live Oak - Drawings and Photos original pdf

Thumbnail of the first page of the PDF
Page 1 of 10 pages

EXISTING GAS VALVE EXISTING POWER POLE SITE RETAINING WALL OVERHEAD UTILITY E N I L B R U C 549.0' . . . . T T T T S S S S K K K K A A A A O O O O E E E E V V V V I I I I L L L L T T T T S S S S A A A A E E E E G PP 549' ' W " 2 2 0 5 ° 2 6 N ' 0 0 0 5 . I E N L Y T R E P O R P Y T I L I T U D A E H R E V O I K L A W E D S G N T S X E I I I K L A W E D S G N T S X E I I W PP OVERHEAD UTILITY SD EXISTING WATER METER EXISTING POWER POLE OV E RH EA D UT ILI TY T H E B U I L D I N G I S O V E R 1 5 ' A 1 5 ' - 0 " W A Y F R O M T H E O H U 547' PATIO AWNING ROOF G N A H R E V O ' 7 . 5 1 O T K C A B T E S T N O R F D E G A R E V A BROOKLYN ST. BROOKLYN ST. BROOKLYN ST. BROOKLYN ST. EXISTING STORM DRAIN MANHOLE CURB LINE N27°20'57"E 99.91' PROPERTY LINE " 0 - ' 5 1 U H O E H T M O R F Y A W A ' 5 1 R E V O S I I G N D L I U B E H T " 0 - ' 5 1 514 E LIVE OAK RESIDENCE F.F.E = 546' -9" A.A.G = 546.5' 1/2 CRZ 548' 10' - 0" I E N L Y T R E P O R P ' E " 3 0 9 3 ° 2 6 S ' 0 0 . 0 5 1/2 CRZ G N A H R E V O K C E D D O O W 544' K C A B T E S D R A Y K C A B ' 0 …

Scraped at: Jan. 13, 2024, 2:13 a.m.
Jan. 10, 2024

16.4 - 514 E LIVE OAK PRESENTATION MATERIALS HLC#4_01.09.2023 original pdf

Thumbnail of the first page of the PDF
Page 1 of 7 pages

9' - 6" 20' - 1" 10' - 4" 8' - 4 1/2" 15' - 4 1/2" 9' - 9 1/2" 5' - 10 1/2" 14' - 2 1/2" 10' - 4" 4' - 2 1/2" 4' - 2 1/2" 7' - 4 1/2" 8' - 0" - --- OVERHANG ABOVE LEVEL 2 ABOVE . 0 1 3 A 2 DN - --- PATIO 303 SF POWDER A5.20 4 S E V L E H S FLEX AREA 4' - 4 1/2" 3' - 5 1/2" 2' - 0" A5.20 1 0' - 0" 4' - 11" 4' - 11" FOYER " 0 - ' 0 8' - 8" " 8 " 7 - ' 2 CLOSET 4' - 2" 3' - 10 1/2" - --- HALLWAY Washer Dryer . T H C - --- CABINETS BELOW W.H. 2' - 9" MUD ROOM 0' - 0" 6' - 1 1/2" 3 A5.20 6 2' - 0 1/2" 5 DW UP " 0 1 3 " 2 / 1 2 - ' 6 " 4 - ' 1 " 7 - ' 2 " 2 / 1 0 - ' 2 4 A5.10 2 1 KITCHEN/DINING " 2 / 1 5 - ' 8 Range LEVEL 2 ABOVE " 2 - ' 4 " 2 / 1 3 - ' 0 1 " 2 / 1 2 - ' 4 1 " 2 / 1 7 - ' 8 2 " 6 " 6 - ' 9 " 1 - ' 7 E V O B A G N A H R E V O A2.20 A2-0 2 1 " 1 1 - ' 1 1 1 A3.10 - --- " 2 / 1 0 - ' 4 " 2 / 1 7 - ' 2 " 4 - ' 2 " 2 / 1 5 - ' 1 " 0 1 - ' 1 " 6 - ' 1 " 2 / 1 1 - ' 2 " 2 / 1 6 - ' 4 1/4" / 1'-0" GARAGE - --- -0' - 4" OVERHANG ABOVE - --- 1' - 10 1/2" 5' - 8" 5' - 1" 4' - 4" 8' - 8" 4' - 4" 7' - 6" 7' - 10 1/2" 20' - 2 1/2" 10' - 9" 17' - 4" 15' - 4 1/2" 15' - 10" 0' - 0" LIVING ROOM - --- 1 2 …

Scraped at: Jan. 13, 2024, 2:13 a.m.
Jan. 10, 2024

17.0 - 1621 W 14th St original pdf

Thumbnail of the first page of the PDF
Page 1 of 5 pages

HISTORIC LANDMARK COMMISSION PERMITS IN NATIONAL REGISTER HISTORIC DISTRICTS DECEMBER 13, 2023 HR-2023-122515; GF-2023-130947 OLD WEST AUSTIN 1621 WEST 14TH STREET 17– 1 PROPOSAL PROJECT SPECIFICATIONS standing-seam metal. ARCHITECTURE RESEARCH DESIGN STANDARDS Remodel existing house entirely, constructing an addition and reconfiguring roofline, changing fenestration and cladding, and adding a second-floor patio accessed by a spiral stair. 1) Construct a shed-roofed stucco addition to the west side of the house. 2) Reconfigure roofline to a shed roof, removing gable and creating a flat-roofed patio beneath. All roofing is to be 3) Replace all windows with undivided fixed and sash windows of varying proportions, creating a new fenestration pattern. 4) Reclad house in stucco paneling. 5) Add metal spiral staircase to access second-floor balcony. One-story Ranch house with horizontal siding, stone water table cladding, an attached carport, and a side-gabled roof. The house at 1621 W. 14th Street was constructed in 1952. Its owners throughout the 1950s were Guy E. and Fannie Huddleston. Guy Huddleston, an Army veteran and major in the Army Reserves, worked as the chief inspector of the State Railroad Commission’s motor transport division. The City of Austin’s Historic Design Standards (March 2021) are based on the Secretary of the Interior’s Standards for Rehabilitation and are used to evaluate projects in National Register districts. The following standards apply to the proposed project: Repair and alterations 1. General standards The proposed project removes all intact historic material from the house’s exterior and changes its form entirely. 3. Roofs The proposed roof reconfiguration is not compatible with the district or the existing house. 4. Exterior walls and trim The proposed stucco paneling does not reflect the design of nearby contributing buildings in the district. 5. Windows, doors, and screens The proposed project removes and replaces all windows and doors and does not maintain existing openings. The new fenestration is not compatible with the district. 6. Porches The proposed project does not retain the existing porch. The proposed second-floor balcony and staircase is not compatible with the district. Summary The project does not meet the applicable standards. PROPERTY EVALUATION The property contributes to the Old West Austin National Register district. 17– 2 Designation Criteria—Historic Landmark 1) The building is more than 50 years old. 2) The building appears to retain high integrity. 3) Properties must meet two criteria for landmark designation (LDC §25-2-352). Staff has evaluated the property and determined that it …

Scraped at: Jan. 13, 2024, 2:13 a.m.
Jan. 10, 2024

17.1 - 1621 W 14th St - Drawings original pdf

Thumbnail of the first page of the PDF
Page 1 of 17 pages

CEILINGJOISTNOTES: (cid:120) (cid:120) (cid:120) ALLCEILINGJOISTSARE2GRADEAND2x6@ 24"O.C.U.N.O. PROVIDESTRONGBACKSPANMORETHAN10' ASSHOWNONDETAIL10ATMIDSPAN. 1-3PLYBEAMSCANBENAILEDTOGETHER. (cid:38)(cid:50)(cid:49)(cid:49)(cid:40)(cid:38)(cid:55)(cid:3)(cid:23)(cid:3)(cid:36)(cid:49)(cid:39)(cid:3)(cid:24)(cid:3)(cid:51)(cid:47)(cid:60)(cid:3)(cid:37)(cid:40)(cid:36)(cid:48)(cid:3)(cid:58)(cid:44)(cid:55)(cid:43)(cid:3)(cid:20)(cid:18)(cid:21)(cid:5)(cid:145) THROUGHBOLTS@24"O.C..TOPAND BOTTOM. VERIFYALLDIMENSIONSAGAINST ARCHITECTURALANDALLOTHERPERTINENT DRAWINGSFORDETAILSNOTSHOWNONTHE STRUCTURALDRAWINGS. LEGEND CEILINGJOIST CEILINGLINE FLOORJOIST TJIORTRUSS LINELOAD STAIR FLOORAREA ROOFBRACELOCATION ENGINEEREDBEAM ALLBEAMSAREDROPPEDU.N.O. (C)-CONCEALEDBEAM (F)-FLOATINGBEAM FURRDOWN LIVINGDINING 8'CLG CLOSET 8'CLG BATHROOM 8'CLG BEDROOM 8'CLG EXISTINGCEIING LIVINGDINING 8'CLG KITCHEN 8'CLG EXISTINGCEIING BATHROOM 8'CLG BONUSROOM 8'CLG EXISTINGCEIING BEDROOM 8'CLG EXISTINGCEIING EXISTINGCEIING BEDROOM 8'CLG 18"=1'-0" 14"=1'-0" 11X17SIZE 22X34SIZE DESIGNEDFORCOMPOSITIONROOF RAFTERSNOTE: (cid:120) ALLRAFTERSARE2GRADE,2x6AND24"O.C. U.N.O. (cid:120) MATERIALLOADUPTO5PSF. (cid:120) ROOFSHEATHINGSHALLBE U.N.O. 5 16"THICKMIN. ROOFNOTES: (cid:120) MATERIALLOADUPTO5PSF. (cid:120) 16"THICKMIN. ROOFSHEATHINGSHALLBE 5 U.N.O. BRACESUPTO6'SHALLBE2X6",LONGER BRACES(6'-16')SHALLBEMADEOF2x6"AND LONGERBRACES(16'-27')SHALLBEMADEOF 2X10"FASTENEDTOGETHERINA"L"OR"T" PATTERN. VERIFYALLDIMENSIONSAGAINST ARCHITECTURAL. ALLPURLINSIZESHALLMATCHRAFTERSIZE ALLFRAMINGANDCONSTRUCTIONMEMBERS TOBEPER2015IRCCODE. (cid:120) (cid:120) (cid:120) (cid:120) VERIFYALLDIMENSIONSAGAINST ARCHITECTURALANDALLOTHERPERTINENT DRAWINGSFORDETAILSNOTSHOWNONTHE STRUCTURALDRAWINGS. LEGEND ENGINEEREDBEAM ROOFBRACE WALLSTACKED PURLIN M A E B N O R A E B O T R E T F A R M A E B N O R A E B O T R E T F A R L L A W N O R A E B O T R E T F A R L L A W N O R A E B O T R E T F A R 18"=1'-0" 14"=1'-0" 11X17SIZE 22X34SIZE VICINITY MAP PROPERTY PROFILE MAP AREA SCHEDULE EXISTING OWNER: AHMED ASHRAF & DARCY ADDRESS: 1621 W 14TH ST AUSTIN, TX 78703-3922 LEGAL DESCRIPTION: ABS 697 SUR 7 SPEAR G W ACR. 142 ZONING: MF-3-NP PROPERTY ID: 110136 GEOGRAPHIC ID:0111030705 LAND: 0.1420 ACRES (6,185.52 SQFT) BUILDING PROGRAM • • • • CONVERSION OF CARPORT AND LAUNDRY TO CONDITIONED SPACE ADDITION OF MASTER SUITE RENOVATION OF KITCHEN EXISTING ROOF DEMOLISHED, NEW ROOF TO BE BUILT SQUARE FOOTAGE CALCULATIONS 1ST FLOOR STORAGE CARPORT 2ND STORAGE OPEN PORCH EXISTING SQ FT. NEW ADDITION IMPERVIOUS SQ FT. CALCS. EXISTING IMPERVIOUS COVERAGE % 25% ADDED IMPERVIOUS COVERAGE % 3% AREA 1188 SQFT 80 SQFT 256 SQFT 63 SQFT 48 SQFT 1572 SQFT 246 SQFT Sheet List Sheet Sheet Name Number Drawn By Approved By A0 TITLE PAGE A101 SITE PLAN A102 FOUNDATION A103 EXISTING FLOOR PLANS A104 PROPOSED FIRST FLOOR PLAN A105 PROPOSED SECOND FLOOR PLAN A106 EXISTING ROOF PLAN PROPOSED ROOF PLAN A107 EXISTING NORTH / SOUTH ELEVATIONS A201 EXISTING EAST / WEST ELEVATIONS A202 PROPOSED NORTH / SOUTH ELEVATIONS A203 A204 PROPOSED EAST / WEST ELEVATIONS A205 KITCHEN ELEVATIONS A301 SECTIONS A501 DETAILS A901 RENDERS A902 RENDERS E101 ELECTRICAL PLAN G1 GENERAL NOTES JESUS A OMAR G JESUS A OMAR G JESUS A OMAR G JESUS A OMAR G JESUS A OMAR G JESUS A OMAR …

Scraped at: Jan. 13, 2024, 2:13 a.m.
Jan. 10, 2024

17.2 - FW_ 1621 W 14th St - HLC Referral & Fees original pdf

Thumbnail of the first page of the PDF
Page 1 of None page

Backup

Scraped at: Jan. 13, 2024, 2:14 a.m.
Jan. 10, 2024

18.0 - 2716 Wooldridge Dr original pdf

Thumbnail of the first page of the PDF
Page 1 of 7 pages

HISTORIC LANDMARK COMMISSION PERMITS IN NATIONAL REGISTER HISTORIC DISTRICTS DECEMBER 13, 2023 HR-2023-149931; GF-2023-150410 OLD WEST AUSTIN NATIONAL REGISTER HISTORIC DISTRICT 2716 WOOLDRIDGE DRIVE 18 – 1 PROPOSAL Demolish a ca. 1940 house. Construct a new residence and pool. PROJECT SPECIFICATIONS The proposed new residence is eclectic in style, with elements of Dutch Colonial Revival, Tudor Revival, and Gothic Revival styles. It is three stories in height, with a compound roofline clad in copper, slate, and architectural shingles with copper finials at gable ends and turret. Roof forms include traditional gables, a turret with cupola, catslide entryway, and gambrel. Exterior cladding includes limestone, sandstone, limewashed brick, limewashed stucco, and decorative faux half- timbering. Fenestration is varied throughout and includes arched doorways and a variety of Tudor Revival-style leaded glass windows of varying dimensions. The detached garage apartment faces the primary streetscape. ARCHITECTURE RESEARCH DESIGN STANDARDS The existing building is a one-story house with a cross-gabled roof, partial-width porch behind a simple loggia, attached carport, and brick cladding. The house at 2716 Wooldridge Drive was constructed around 1940. Its long-term residents were Helen and Harry Joseph. Harry Joseph, whose family owned several prominent businesses during the twentieth century, operated Harry’s Liquor Store and Schoonerville, a beer store. Eventually, Joseph and his father opened Centennial Liquor, as well as Austin’s first import business.1 The Josephs remained in the home until at least 1972. The City of Austin’s Historic Design Standards (March 2021) are based on the Secretary of the Interior’s Standards for Rehabilitation and are used to evaluate projects in National Register districts. The following standards apply to the proposed project: Residential new construction 1. Location The proposed primary building appears appropriately set back; however, the garage apartment is located at the front of the lot. 2. Orientation The proposed house is oriented toward the primary streetscape. The proposed garage apartment is not oriented consistently with similar outbuildings in the district. 3. Scale, massing, and height The proposed building is larger in scale, taller in height, and more complex in massing than most contributing buildings in the district. 4. Proportions The proposed building’s proportions do not appear consistent with contributing buildings in the district. 5. Design and style The proposed building’s eclectic design and style, while differentiated from other buildings in the district, is not compatible. 6. Roofs The proposed roof form and materials do not reflect the styles of contributing buildings …

Scraped at: Jan. 13, 2024, 2:14 a.m.
Jan. 10, 2024

18.1 - 2716 Wooldridge Dr - drawings original pdf

Thumbnail of the first page of the PDF
Page 1 of 8 pages

2 NORTH SIDE 3 SOUTH SIDE EXISTING BUILDING FOOTPRINT 4 EAST SIDE 5 WEST SIDE 1 EXISTING SURVEY NOTE: This document, the ideas and design incorporated herein are and shall remain the property of Jameson Design Group. These documents are not to be used or altered, in whole or in part, for other than the original intended use, nor are they to be assigned to any third party without written permission from Jameson Design Group. © JDG 2023 E M O H K C O L D E M N O S L E N - e g d i r l d o o W 6 1 7 2 3 0 7 8 7 X T , n i t s u A DATE: PHASE: BY: 11.17.23 HIST. REV. MV/MC DATE: 11.17.23 SIZE/SCALE: 24 x 36 1/8"=1'-0" 11 x 17 1/16"=1'-0" EXISTING SITE PLAN AND EXTERIOR EXIST PROPOSED EXTERIOR FINISHES Chocolate Sandstone Limestone Shell Old Brick (Parging/ Limewash) Stucco/Limewash Leaded Glass PROPOSED EXTERIOR FINISHES Copper Roofing (Patina) Slate Carriage House Style Shingles Copper Gutters and Downspouts Copper Finials S

Scraped at: Jan. 13, 2024, 2:14 a.m.
Jan. 10, 2024

18.2 - 2716 Wooldridge Dr_HLC_01.10.24 - presentation_compressed original pdf

Thumbnail of the first page of the PDF
Page 1 of 29 pages

2716 Wooldridge Drive Secondary Historic Landmark Commission Review (01.10.2024) Neighborhood Analysis per Historic Landmark Commission Comments on 12/13/23: - Garage Placement and Orientation - Scale, Height, Massing, and Proportions - Design and Style of Home and Neighborhood - Roofs, Exterior Walls, Windows and Doors - Chimney and Materials ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ S E T B A C K 1 0 ' - 0 " N GARDEN AREA 5'-0" SETBACK 5'-0" SETBACK POOL COURTYARD PRIMARY BEDROOM GARDEN AREA GARAGE +/-8'-6" T.B.D. +/-11'-31 2" T.B.D. ' 2 5 - 0 " S E T B A C K DRIVEWAY 2 9 ' - 0 " LARGE TREE & CRITICAL ROOT ZONE 1 ARCHITECTURAL SITE PLAN E M O H K C O L D E M N O S L E N - e g d i r l d o o W 6 1 7 2 3 0 7 8 7 X T , n i t s u A N O T F O R R E G U L A T O R Y A P P R O V A L, P E R MITTIN G O R C O N S T R U C TIO N DATE: PHASE: BY: 10.06.23 11.10.23 11.17.23 12.26.23 01.09.24 SCHEM. MV/MC D.D. REV. MV HIST. REV. MV D.D. REV. MV HIST. REV. MC/MV DATE: 01.09.24 SIZE/SCALE: 24 x 36 1/8"=1'-0" 11 x 17 1/16"=1'-0" ARCHITECTURAL SITE PLAN A0.0 NOTE: This document, the ideas and design incorporated herein are and shall remain the property of Jameson Design Group. These documents are not to be used or altered, in whole or in part, for other than the original intended use, nor are they to be assigned to any third party without written permission from Jameson Design Group. © JDG 2024 POOL OUTDOOR COOKING (GRILL AND UNDER COUNTER FRIDGE) HIS CLOSET 4'-7" X 8'-2" HIS BATHROOM 8'-6" X 8'-2" PRIMARY BEDROOM 15'-10" X 15'-6" HER BATHROOM 13'-8" X 9'-4" COURTYARD 16'-8" X 13'-2" EXERCISE 12'-0" X 12'-10" STORAGE SHELVES GLASS LITE POCKET DOORS STORAGE KITCHEN 20'-4" X 10'-6" LAUNDRY 11'-5" X 8'-6" BREEZEWAY (ARCHED OPENINGS) HIDDEN PANTRY 8'-4" X 8'-0" GLASS PANEL DOORS OFFICE POWDER 5'-5" X 5'-5" ELEVATOR SHELVES (ART, BOOKS) SHELVES FOYER 16'-0" X 7'-4" COAT CLOSET CIRCULAR STAIRWELL STORAGE DEN (MUSIC) 14'-0" X 17'-4" BUILT-IN DINING ROOM 11'-6" X 12'-0" STORAGE DOOR AND WINDOW …

Scraped at: Jan. 13, 2024, 2:14 a.m.
Jan. 10, 2024

18.a - 2716 Wooldridge Dr - public comment original pdf

Thumbnail of the first page of the PDF
Page 1 of 1 page

Backup

Scraped at: Jan. 13, 2024, 2:14 a.m.
Jan. 10, 2024

19.0 - 1610 Preston Ave original pdf

Thumbnail of the first page of the PDF
Page 1 of 2 pages

27 – 1 HISTORIC LANDMARK COMMISSION PERMITS IN NATIONAL REGISTER HISTORIC DISTRICTS DECEMBER 13, 2023 HR-2023-147071; GF-2023-149161 OLD WEST AUSTIN NATIONAL REGISTER HISTORIC DISTRICT 1610 PRESTON AVENUE PROPOSAL PROJECT SPECIFICATIONS DESIGN STANDARDS Construct a new residence, detached garage, and accessory dwelling unit. The existing building was approved for demolition by the Historic Landmark Commission in November 2023. The proposed new building is a one-story Tudor Revival house, clad in painted brick with a compound roofline and divided- light windows. The City of Austin’s Historic Design Standards (March 2021) are based on the Secretary of the Interior’s Standards for Rehabilitation and are used to evaluate projects in National Register districts. The following standards apply to the proposed project: Residential new construction 1. Location The proposed new house and garage appear appropriately set back and sited. 2. Orientation The proposed buildings match the orientations of contributing buildings in the district. 3. Scale, massing, and height The building’s scale and height appear appropriate; however, its massing is more complex than most contributing buildings’ massing nearby. 4. Proportions The building’s proportions are somewhat compatible; though the steep gables emphasize its height, they are stylistically appropriate. 5. Design and style The building’s design and style appear internally consistent. The Tudor Revival detailing is appropriate for the district’s period of significance and appears sufficiently differentiated. 6. Roofs The compound roofline is much more complex than surrounding contributing buildings’ rooflines. 7. Exterior walls The proposed painted brick is compatible. 8. Windows and doors Fenestration is mostly compatible and helps to differentiate the building. Summary The project meets most of the applicable standards. STAFF RECOMMENDATION Comment on plans, encouraging simpler massing. LOCATION MAP 27 – 2

Scraped at: Jan. 13, 2024, 2:14 a.m.
Jan. 10, 2024

19.1 - 1610 Preston Ave - drawings original pdf

Thumbnail of the first page of the PDF
Page 1 of 6 pages

OVERVIEW - - - - 4 BEDROOM / 3.5 BATH HOME WITH DETACHED REAR GARAGE DESIGN AESTHETICS IN KEEPING WITH NEIGHBORHOOD CHARACTER IN BOTH DETAIL AND SCALE SIDE PORTE COCHERE ON THE SIDE OF HOUSE TRADITIONAL BRICK AND SIDING EXTERIOR MATERIALS PRESTON PLANS SCALE : 3/16" = 1'-0" PRESTON INSPIRATION REFERNCE PLANS SCALE : 3/16" = 1'-0" 42 FIREPLACE 74" FIREPLACE CLOSET POOL 30'X12' LIVING 10'-0" CLG DINING 10'-0" CLG OFFICE 10' CLG ENTRY 10' CLG UP BATHRM 10' CLG LAUNDRY/ PANTRY 10'-0" CLG CARPORT 10'-0" CLG " 0 - ' 0 1 OUTDOOR PATIO BBQ 24" DW KITCHEN 10'-0" CLG 48" REF/FRZ STORAGE BUILT-IN MUDRM 10' CLG UP GARGAGE 10'-0" CLG 10'X8' DOOR OPENING PRESTON 1ST FL 1596 SF 2ND FL 1551 SF ATTICS 415 SF PARKING 653 SF TOTAL CONDITIONED 3562 SF SITE PLAN SCALE : 3/32" = 1'-0" 42 FIREPLACE 74" FIREPLACE CLOSET LIVING 10'-0" CLG 24" DW KITCHEN 10'-0" CLG DINING 10'-0" CLG OFFICE 10' CLG ENTRY 10' CLG UP BATHRM 10' CLG LAUNDRY/ PANTRY 10'-0" CLG CARPORT 10'-0" CLG " 0 - ' 0 1 OUTDOOR PATIO BBQ 48" REF/FRZ STORAGE BUILT-IN MUDRM 10' CLG Rodenberg Design PRESTON 1ST FL PLANS SCALE : 3/16" = 1'-0" BATHRM 9' CLG CLOSET CLOSET BEDROOM 9' CLG BEDROOM 9' CLG PRIM BATHRM 9' CLG LINEN BATHRM 9' CLG COVERED PORCH VAULTED CLG PRIM BEDRM VAULTED CLG DN FAMILY ROOM 9' CLG PRIM CLOSET 9' CLG S E V L E H S N I - T L I U B 5' 7' RIDGE 7' 5' FLEX SPACE SLP CLG RIDGE 5' 7' 7' 5' STORAGE RIDGE 5' 7' 7' 5' PRESTON 2ND FL PLANS SCALE : 3/16" = 1'-0" UP GARGAGE 10'-0" CLG 10'X8' DOOR OPENING DN FLEX SPACE SLP CLG 1ST FL 2ND FL PRESTON DETACHED REAR GARAGE PLANS SCALE : 3/16" = 1'-0"

Scraped at: Jan. 13, 2024, 2:14 a.m.
Jan. 10, 2024

19.2 - 1610 Preston Ave - Owner Letter original pdf

Thumbnail of the first page of the PDF
Page 1 of 1 page

Historical landmark commission, As the owner representative of our family’s estate we are wholeheartedly in agreement for a demolition permit to be issued. There are severe foundation and structural roofing conditions that have been prevalent for years that we have dealt with. We feel that there is nothing about our home that would contribute to a national historical district. Again we approve and support a demolition permit to be issued so we can better help and serve our family. Historical landmark commission, As the owner and representative of my family’s estate, we wholeheartedly, approve and agree on a demolition permit for the structure. The failing roof and foundation have been a problem for years. We also feel there is zero contributing attributes of this home and its shape, appearance or materials used that word contribute any kind of significance at all to a national historical registry. We fully support and approve the demolition to better help our family and our futures. Murrey Swanson DocuSign Envelope ID: 76F5B166-AF42-4994-A77E-67FE16726654Murrey Swanson10/23/2023

Scraped at: Jan. 13, 2024, 2:14 a.m.
Jan. 10, 2024

19.3 - 1610 Preston Ave - Photos original pdf

Thumbnail of the first page of the PDF
Page 1 of 2 pages

Backup

Scraped at: Jan. 13, 2024, 2:15 a.m.
Jan. 10, 2024

19.4 - 1610 Preston Ave - Drawings original pdf

Thumbnail of the first page of the PDF
Page 1 of 6 pages

OVERVIEW - - - - 4 BEDROOM / 3.5 BATH HOME WITH DETACHED REAR GARAGE DESIGN AESTHETICS IN KEEPING WITH NEIGHBORHOOD CHARACTER IN BOTH DETAIL AND SCALE SIDE PORTE COCHERE ON THE SIDE OF HOUSE TRADITIONAL BRICK AND SIDING EXTERIOR MATERIALS PRESTON PLANS SCALE : 3/16" = 1'-0" PRESTON INSPIRATION REFERNCE PLANS SCALE : 3/16" = 1'-0" 42 FIREPLACE 74" FIREPLACE CLOSET POOL 30'X12' LIVING 10'-0" CLG DINING 10'-0" CLG OFFICE 10' CLG ENTRY 10' CLG UP BATHRM 10' CLG LAUNDRY/ PANTRY 10'-0" CLG CARPORT 10'-0" CLG " 0 - ' 0 1 OUTDOOR PATIO BBQ 24" DW KITCHEN 10'-0" CLG 48" REF/FRZ STORAGE BUILT-IN MUDRM 10' CLG UP GARGAGE 10'-0" CLG 10'X8' DOOR OPENING PRESTON 1ST FL 1596 SF 2ND FL 1551 SF ATTICS 415 SF PARKING 653 SF TOTAL CONDITIONED 3562 SF SITE PLAN SCALE : 3/32" = 1'-0" 42 FIREPLACE 74" FIREPLACE CLOSET LIVING 10'-0" CLG 24" DW KITCHEN 10'-0" CLG DINING 10'-0" CLG OFFICE 10' CLG ENTRY 10' CLG UP BATHRM 10' CLG LAUNDRY/ PANTRY 10'-0" CLG CARPORT 10'-0" CLG " 0 - ' 0 1 OUTDOOR PATIO BBQ 48" REF/FRZ STORAGE BUILT-IN MUDRM 10' CLG Rodenberg Design PRESTON 1ST FL PLANS SCALE : 3/16" = 1'-0" BATHRM 9' CLG CLOSET CLOSET BEDROOM 9' CLG BEDROOM 9' CLG PRIM BATHRM 9' CLG LINEN BATHRM 9' CLG COVERED PORCH VAULTED CLG PRIM BEDRM VAULTED CLG DN FAMILY ROOM 9' CLG PRIM CLOSET 9' CLG S E V L E H S N I - T L I U B 5' 7' RIDGE 7' 5' FLEX SPACE SLP CLG RIDGE 5' 7' 7' 5' STORAGE RIDGE 5' 7' 7' 5' PRESTON 2ND FL PLANS SCALE : 3/16" = 1'-0" UP GARGAGE 10'-0" CLG 10'X8' DOOR OPENING DN FLEX SPACE SLP CLG 1ST FL 2ND FL PRESTON DETACHED REAR GARAGE PLANS SCALE : 3/16" = 1'-0"

Scraped at: Jan. 13, 2024, 2:15 a.m.
Jan. 10, 2024

19.5 - 1610 PRESTON PLANS original pdf

Thumbnail of the first page of the PDF
Page 1 of 4 pages

) T A L P ( E U P ' 5 15'-0" ELEC CLEARANCE H O H O H O H O H O 5 0 6 ' 9 9 . 9 5 E " 3 4 9 3 ° 2 6 S ' ) ' 0 6 E ° 0 6 S ( H O H O H O H O H O H O H O H O H O H O H O 20" YELLOWWOOD S 26°00'51" W 137.38' (S 30° W 137.5') 10" PECAN LOT SQUARE FOOTAGE 8,233 SQ. FT. 15.5" LIGUSTRUM 604 603 602 5' BL (ZONING) FIREPLACE 3x7 3x7 FIREPLACE POOL POOL 30'X12' 30'X12' LIVING 10'-0" CLG 9.5" LIGUSTRUM TEMPORARY BENCHMA ELEVATION = 60 CLOSET 2'6x6 OFFICE 10' CLG 14x12 5x6'6 9x8'6 DINING 10'-0" CLG PANTRY 10'-0" CLG BATHRM 10' CLG ENTRY 10' CLG 3x8'6 3x8'6 UP 4x7 3x7 CARPORT 10'-0" CLG " 0 - ' 0 1 15x9 10x9 UP GARGAGE 10'-0" CLG 10'X8' DOOR OPENING 24" DW KITCHEN 10'-0" CLG OUTDOOR PATIO BBQ 4x6 48" REF/FRZ STORAGE 3x9 BUILT-IN MUDRM 10' CLG 2x4 24" LIVE OAK 5' BL (ZONING) N 25°58'05" E 137.44' (N 30° E 137.5') ' 8 8 . 9 5 W ' " 9 3 2 4 ° 2 6 N ) ' 0 6 W ° 0 6 N ( E U N E V A N O T S E R P ) . . W O R . ' 0 5 ( 1ST FL 1619 SF 2ND FL 1567 SF ATTICS 415 SF PARKING 653 SF TOTAL CONDITIONED 3601 SF SITE PLAN SCALE : 3/32" = 1'-0" PRESTON FIREPLACE CLOSET 3x7 3x7 FIREPLACE 15x9 10x9 LIVING 10'-0" CLG 24" DW KITCHEN 10'-0" CLG OUTDOOR PATIO BBQ 4x6 48" REF/FRZ STORAGE 3x9 BUILT-IN MUDRM 10' CLG 2x4 9x8'6 DINING 10'-0" CLG PANTRY 10'-0" CLG BATHRM 10' CLG ENTRY 10' CLG 2'6x6 OFFICE 10' CLG 14x12 5x6'6 3x8'6 3x8'6 UP 4x7 3x7 CARPORT 10'-0" CLG " 0 - ' 0 1 Rodenberg Design PRESTON 1ST FL PLANS SCALE : 3/16" = 1'-0" 2'6x6 2'6x6 2'6x6 2'6x6 2x4 BATHRM 9' CLG CLOSET CLOSET BEDROOM 9' CLG 11x11 BEDROOM 9' CLG 11x11 6x8 PRIM BATHRM 9' CLG LINEN BATHRM 9' CLG COVERED PORCH VAULTED CLG 12x8 PRIM BEDRM VAULTED CLG 17x14 PRIM CLOSET 9' CLG S E V L E H S N I - T L I U B …

Scraped at: Jan. 13, 2024, 2:15 a.m.
Jan. 10, 2024

2.0 - Updated_HLC Heritage Preservation Grant FY24 Recommendations and Project Updates 011024 original pdf

Thumbnail of the first page of the PDF
Page 1 of 13 pages

Heritage Preservation Grant​ FY24 RECOMMENDATIONS ​ Equitable Funding Review Goal The desired goal is to sustain and grow Austin’s cultural infrastructure so that all may share in the economic and employment benefits of the heritage preservation and creative sectors, as well as upholding the City’s commitment to racial equity per the City of Austin’s Equity Office standards and goals. CITY OF AUSTIN ECONOMIC DEVELOPMENT 2 Grant Overview The Heritage Preservation Grant promotes tourism by restoring historic sites, and through planning, educational, or marketing projects. Projects should tell inclusive stories on historic places rooted in Austin's history and heritage. Based on State Statute Ch. 351, the project must: • • Be used for historical restoration and preservation projects or activities to encourage tourism to visit preserved historic sites. • At, or in the immediate vicinity of, Convention Center facilities or visitor information centers; Located in the areas that would be frequented by tourists and convention delegates CITY OF AUSTIN ECONOMIC DEVELOPMENT 3 Program Highlights • Historic preservation projects and history-informing activities that promote heritage tourism • Contract Term: 2-yr Grant • Eligible: Non-Profit and For Profit (leased or owned) • Funds preservation project costs (no match) • Optional Fees: Insurance • • 10% Project Management (Capital only) • Tourism Marketing Training in Eng/Spn REQUIREMENTS • Historic designated sites that promote heritage tourism (or be eligible) • Marketed to increase/benefit tourism and expand audiences • Accessible grounds • Occurs in Austin City Council District • Resides within MSA with Austin programming experience for at least 2 years (applicant) CITY OF AUSTIN ECONOMIC DEVELOPMENT 4 Priorities • Outreach to First-time Applicants; • Tourism-serving properties listed in the East Austin Historic Survey; • Inclusive Interpretive Plans & Story-Telling: Projects that share Austin’s history in a fresh and compelling way; • Creative Collaborations Encouraged: Partnerships between historic properties and community organizations; • Tourism: Use of innovative and inclusive methods to attract new and diverse audiences and tourists. • Promotion of local historic designation CITY OF AUSTIN ECONOMIC DEVELOPMENT 5 Grant Overview Owner authorization is required for all project proposals Historic Designation Project Budget and Bid Selection Process Now Eligible Capital Planning Educational Marketing Local, State or National Designation (or Eligible) Required Local, State or National Designation (or Eligible) Required Local, State or National Designation (or Eligible) Required Local, State or National Designation (or Eligible) Required Project Budget and Outside Consultant Bids for Each Activity; Match …

Scraped at: Jan. 13, 2024, 2:15 a.m.
Jan. 10, 2024

20.0-4106 Lullwood Rd original pdf

Thumbnail of the first page of the PDF
Page 1 of 5 pages

19 – 1 HISTORIC LANDMARK COMMISSION PERMITS IN NATIONAL REGISTER HISTORIC DISTRICTS JANUARY 10, 2024 HR-2023-155105 WILSHIRE WOOD NATIONAL REGISTER HISTORIC DISTRICT 4106 LULLWOOD ROAD PROJECT SPECIFICATIONS PROPOSAL shingled roof. ARCHITECTURE RESEARCH DESIGN STANDARDS Construct an addition to a ca. 1951 house. Remodel the garage and replace doors and windows at rear of house. Install new door in place of existing window. 1) Construct an addition to the front of the garage toward the street. The proposed addition is clad in wood siding, with a 2) Add a roll-up door the rear of the existing garage. 3) Replace door and windows at rear of house. Replace window at front of house with door. One-story Ranch house with cutstone veneer, multilight sliding and casement windows, and front-facing garage. 4106 Lullwood Road was built in 1951. Its first occupants were Carl G. and Lois Shepard. Carl Shepard owned and operated a furniture distribution company located on East 6th Street. By 1959, it had been sold to rancher Earl Tucker, and to R. S. Merrill by 1970. The City of Austin’s Historic Design Standards (March 2021) are based on the Secretary of the Interior’s Standards for Rehabilitation and are used to evaluate projects in National Register districts. The following standards apply to the proposed project: Repair and alterations 1. General standards The proposed project removes some historic material from the building’s exterior. 4. Exterior walls and trim The proposed wood siding differentiates the new material from the old; however, it partially replaces some of the original cutstone cladding. 5. Windows, doors, and screens While most of the window replacements are at the rear of the building and are therefore appropriate, the replacement of a front window with a door is not compatible. 8. Attached garages and carports The proposed garage alterations somewhat maintain the existing proportions and roofline, though changes will be highly visible from the street. Summary The project somewhat meets the applicable standards. PROPERTY EVALUATION The property contributes to the Wilshire Wood National Register district. Designation Criteria—Historic Landmark 1) The building is more than 50 years old. 2) The building appears to retain high integrity. 3) Properties must meet two criteria for landmark designation (LDC §25-2-352). Staff has evaluated the property and determined that it does not meet two criteria: a. Architecture. The building is a good example of the vernacular Ranch style. b. Historical association. The property does not appear …

Scraped at: Jan. 13, 2024, 2:15 a.m.
Jan. 10, 2024

20.1 - 4106 Lullwood Rd - drawings original pdf

Thumbnail of the first page of the PDF
Page 1 of None page

Backup

Scraped at: Jan. 13, 2024, 2:15 a.m.
Jan. 10, 2024

21.0-1100 Lorrain St original pdf

Thumbnail of the first page of the PDF
Page 1 of 2 pages

HISTORIC LANDMARK COMMISSION PERMITS IN NATIONAL REGISTER HISTORIC DISTRICTS JANUARY 10, 2024 HR-2023-155129 WEST LINE NATIONAL REGISTER HISTORIC DISTRICT 1100 LORRAIN STREET 20 – 1 PROPOSAL Construct a new two-story ADU. PROJECT SPECIFICATIONS DESIGN STANDARDS The proposed ADU is two stories, with living space above a ground-floor garage. It is located at the rear of the lot and is clad in wood siding with an asphalt shingle roof. The City of Austin’s Historic Design Standards (March 2021) are based on the Secretary of the Interior’s Standards for Rehabilitation and are used to evaluate projects in National Register districts. The following standards apply to the proposed project: Residential new construction 1. Location The proposed ADU is located at the rear of the lot, behind the main house. 2. Orientation The proposed ADU is oriented consistently with other detached accessory buildings in the district. 3. Scale, massing, and height and 4. Proportions The proposed scale, massing, height, and proportions appear compatible; the building will be minimally visible. 5. Design and style The proposed building’s design and style are simple and consistent. 6. Roofs The proposed cross-gabled roof appears appropriate. 7. Exterior walls Exterior horizontal siding is appropriate. 8. Windows and doors The proposed fenestration is compatible, though the blank wall at the secondary elevation is less compatible. 11. Attached garages and carports See 2. The project mostly meets the applicable standards. STAFF RECOMMENDATION Comment on plans. LOCATION MAP 20 – 2

Scraped at: Jan. 13, 2024, 2:15 a.m.
Jan. 10, 2024

21.1 - 1100 Lorrain St - drawings original pdf

Thumbnail of the first page of the PDF
Page 1 of 4 pages

MORRIS RESIDENCE PROJECT ADDRESS CONSULTANTS e g a P GIST E R E D AR L EE A N B I I R B E R C H I T S E H O P C T S T A T 18 1 1 2 E FO T X E SA 12/01/2023 DRAWING LIST ABBREVIATIONS KEYNOTES L E D O M E R N E H C T K & U D A W E N I I E C N E D S E R S R R O M I S A X E T , I N T S U A A1.1 50% FULL CRZ: 726 sq.ft. TOTAL COVERAGE: 843 sq.ft. FULL CRZ: 1,452 sq.ft. ADU COVERAGE: 530 sq.ft. . t f . q s 7 3 Y N O C L A B DRIVE STRIPS COVERAGE: 69 sq.ft. E. PORCH COVERAGE: 207 sq.ft. GENERAL TREE SCHEDULE KEYNOTES e g a P GIST E R E D AR L EE A N B I I R B E R C H I T S E H O P C T S T A T 18 1 1 2 E FO T X E SA 12/01/2023 L E D O M E R N E H C T K & U D A W E N I I E C N E D S E R S R R O M I S A X E T , I N T S U A A1.2 Y R T N A P LIVING / KITCHEN BEDROOM D E R E V O C N U Y N O C L A B GARAGE D E R E V O C H C R O P KEYNOTES LEGEND GENERAL WALL TYPES WINDOWS & DOORS e g a P GIST E R E D AR L EE A N B I I R B E R C H I T S E H O P C T S T A T 18 1 1 2 E FO T X E SA 12/01/2023 L E D O M E R N E H C T K & U D A W E N I I E C N E D S E R S R R O M I S A X E T , I N T S U A EXTERIOR WALL NOTES ’ A2.1 GENERAL KEYNOTES e g a P …

Scraped at: Jan. 13, 2024, 2:15 a.m.
Jan. 10, 2024

21.a - 1100 Lorrain St - public comment original pdf

Thumbnail of the first page of the PDF
Page 1 of 1 page

Backup

Scraped at: Jan. 13, 2024, 2:15 a.m.
Jan. 10, 2024

22.0-3001 Funston St original pdf

Thumbnail of the first page of the PDF
Page 1 of 2 pages

HISTORIC LANDMARK COMMISSION PERMITS IN NATIONAL REGISTER HISTORIC DISTRICTS JANUARY 10, 2024 HR-2023-128292 OLD WEST AUSTIN NATIONAL REGISTER HISTORIC DISTRICT 3001 FUNSTON STREET 21 – 1 PROPOSAL Construct a new residence. PROJECT SPECIFICATIONS DESIGN STANDARDS The proposed new building is two stories in height and capped with a compound shed and cross-gabled roof with decorative cedar brackets at gable ends. It is clad in board-and-batten and horizontal siding and features fixed and single-hung windows. The proposed garage is located at the secondary 30th Street elevation. The City of Austin’s Historic Design Standards (March 2021) are based on the Secretary of the Interior’s Standards for Rehabilitation and are used to evaluate projects in National Register districts. The following standards apply to the proposed project: Residential new construction 1. Location The proposed new building is located roughly at the center of the corner lot. 2. Orientation The proposed new building’s orientation is consistent with the orientation of the previous contributing building. 3. Scale, massing, and height The proposed building is larger in scale and height and more complex in massing than nearby contributing buildings; however, its design utilizes step-downs in building form that helps to minimize the building’s overall scale. 4. Proportions Proposed proportions are somewhat compatible. 5. Design and style The proposed design and style is consistent, but only somewhat reflects the surrounding district. 6. Roofs The compound roof is more complex than contributing buildings’ roofs. The triangular brackets at gable ends may give the appearance of false historicism, though this may be mitigated by the rest of the building’s modern design elements. 7. Exterior walls Exterior walls are somewhat appropriate, though board-and-batten appears mostly on outbuildings rather than historic-age primary buildings. 8. Windows and doors Proposed fenestration is mostly compatible at primary elevations. 9. Porches The proposed porch is mostly compatible. 11. Attached garages and carports The proposed garage is set back from the front wall of the house. Summary The project meets some of the applicable standards. STAFF RECOMMENDATION Comment on plans. LOCATION MAP 21 – 2

Scraped at: Jan. 13, 2024, 2:15 a.m.
Jan. 10, 2024

22.1 - 3001 Funston original pdf

Thumbnail of the first page of the PDF
Page 1 of 20 pages

Historic Review Application For Office Use Only Date of Submission:__________________________ Plan Review #: ______________________________ Property Address: _____________________________________________________________________ Historic Landmark Historic District (Local) National Register Historic District Historic Landmark or Historic District Name:______________________________________________________________________________________________ Applicant Name: _______________________________ Phone #: ______________________ Email: ______________________________ Applicant Address: _______________________________ City: _______________________ __ State: ________________ Zip: __________ Please describe all proposed exterior work with location and materials. If you need more space, attach an additional sheet. PROPOSED WORK LOCATION OF PROPOSED WORK PROPOSED MATERIAL(S) 1) 2) 3) Submittal Requirements 1. One set of dimensioned building plans. Plans must: a) specify materials and finishes to be used, and b) show existing and proposed conditions for alterations and additions. Site Plan Elevations Floor Plan Roof Plan 2. Color photographs of building and site: Elevation(s) proposed to be modified Detailed view of each area proposed to be modified Any changes to these plans must be reviewed and approved by the Historic Preservation Office and/or Historic Landmark Commission. Applicant Signature: ___________________________________________ Date: ____________________________ Design Standards and Guidelines for Historic Properties Adopted December 2012 Design Standards and Guidelines for Historic Properties Landmarks and National Register historic district properties If you are making changes to a historic landmark, the project must comply with these standards to receive a Certificate of Appropriateness. If you are making changes to a contributing property or constructing a new building within a National Register historic district, consider the standards below as advisory guidelines: 1. Use a property for its historic purpose or place it in a new use that requires minimal change to the defining characteristics of the building and its site and environment. 2. Retain and preserve the historic character or a property shall be retained and preserved. Avoid the removal of historic materials or alteration of features and spaces that characterize a property. 3. Recognize each property as a physical record of its time, place, and use. Changes that create a false sense of historical development, such as adding conjectural features or architectural elements from other buildings, shall not be undertaken. 4. Most properties change over time; those changes that have acquired historic significance in their own right shall be retained and preserved. 5. Distinctive features, finishes, and construction techniques or examples of craftsmanship that characterize a historic property shall be preserved. 6. Deteriorated historic features shall be repaired rather than replaced. Where the severity of deterioration requires visual qualities and, where possible, materials. Replacement of …

Scraped at: Jan. 13, 2024, 2:15 a.m.
Jan. 10, 2024

23.0-519 E Mary St original pdf

Thumbnail of the first page of the PDF
Page 1 of 2 pages

HISTORIC LANDMARK COMMISSION PERMITS IN NATIONAL REGISTER HISTORIC DISTRICTS JANUARY 10, 2024 HR-2023-159503 TRAVIS HEIGHTS-FAIRVIEW PARK NATIONAL REGISTER HISTORIC DISTRICT 519 EAST MARY STREET 22 – 1 PROPOSAL Construct a new residence with pool and carport. PROJECT SPECIFICATIONS The proposed new building is two stories in height. It is clad in stone veneer and standing seam metal and features twin front-facing second-floor gables with floor-to-roofline glass. Fenestration also includes large fixed undivided windows, a front-facing garage, and undivided casements. DESIGN STANDARDS The City of Austin’s Historic Design Standards (March 2021) are based on the Secretary of the Interior’s Standards for Rehabilitation and are used to evaluate projects in National Register districts. The following standards apply to the proposed project: Residential new construction 1. Location The proposed house is set back approximately 40’. 2. Orientation The proposed building is oriented toward the primary streetscape, with the carport facing East Mary Street. 3. Scale, massing, and height The proposed building appears consistent in scale and height with surrounding buildings, but its massing does not reflect the massing of contributing buildings in the district. 4. Proportions The building’s proportions do not reflect the proportions of nearby contributing buildings. 5. Design and style The building’s design and style are internally consistent, but the double gable and monumental stone massing components do not appear compatible with the district. 6. Roofs See 5. 7. Exterior walls The proposed metal cladding is not compatible, though the stone is somewhat compatible. 8. Windows and doors While the proposed second floor’s transparency makes it more compatible, the offset undivided windows at the first floor are not compatible. 11. Attached garages and carports The proposed carport is not set back from the front wall of the house. Summary The project meets few applicable standards. STAFF RECOMMENDATION Comment on plans. Consider inviting the applicant to the next Architectural Review Committee meeting, as the property is adjacent to the Mary Street Historic District. LOCATION MAP 22 – 2

Scraped at: Jan. 13, 2024, 2:16 a.m.
Jan. 10, 2024

23.1 - 519 EAST MARY_ original pdf

Thumbnail of the first page of the PDF
Page 1 of None page

Backup

Scraped at: Jan. 13, 2024, 2:16 a.m.
Jan. 10, 2024

24.0-218 E 6th St original pdf

Thumbnail of the first page of the PDF
Page 1 of 14 pages

HISTORIC LANDMARK COMMISSION PERMITS IN NATIONAL REGISTER HISTORIC DISTRICTS JANUARY 10, 2024 HR-2023-160720 SIXTH STREET NATIONAL REGISTER HISTORIC DISTRICT 218 EAST 6TH STREET/600-602 SAN JACINTO STREET 23 – 1 PROPOSAL PROJECT SPECIFICATIONS Paint and repair storefront. Install new exterior vestibule at entrance. Install new metal awning. Replace deteriorated windows on the second floor to match existing. 1) Paint and repair existing stucco façade as needed. Repair and repaint upper-story pediments, replace deteriorated cornice details in-kind, repair and repaint storefront as needed. 2) Repair upper windows where possible, replacing in-kind where deteriorated beyond repair. Install new aluminum- 3) 4) clad windows in first-floor infilled arches. Install new metal awning at existing attachment points. Install new central-bay entry vestibule, set back 42”, to match existing flanking storefront windows. Install new light fixtures at entry. ARCHITECTURE RESEARCH Two-story stucco-over-brick structure with large arched openings at the street level and a deep pressed metal cornice. An awning installed in the 1930s has been removed, though connection points are evident. The building at 218 E. 6th Street was constructed around 1880. Its first occupant, the Gambrinus Saloon, was opened by O. Schubert and run by August Fuhrmann, though Fuhrmann’s stake in the business is unclear until the 1890s, when Austin city directories list him as the saloon’s proprietor. The saloon remained in business until after the turn of the twentieth century, when it became a grocer, a tire shop, and a furniture and carpet showroom owned by Felix Smith. After a brief vacancy, A. W. Brill opened a saddlery there in 1920 before purchasing his own building a block away. From the 1930s onward, the building was home to a variety of furniture stores: first the Gregory Furniture Store, owned by City Council- hopeful Tom Gregory; then the Brown-Sellers Company, operated by seasoned salesmen J.S. Brown and C.A. Sellers; then the short-lived Dayton Furniture Company, and finally the Craddock Furniture Company, who also owned the adjoining building. The building was later purchased by Dr. Ben Oran White, son of Councilman Ben White, and rented to a theater. DESIGN STANDARDS The City of Austin’s Historic Design Standards (March 2021) are based on the Secretary of the Interior’s Standards for Rehabilitation and are used to evaluate projects in National Register districts. The following standards apply to the proposed project: Repair and alterations 1. General standards The proposed project specifies that historic-age material will be replaced in-kind only …

Scraped at: Jan. 13, 2024, 2:16 a.m.
Jan. 10, 2024

24.1 - 218 E 6th_HLC_Presentation original pdf

Thumbnail of the first page of the PDF
Page 1 of 8 pages

S IXT H S TRE ET HI STORI C D I STRI CT REVITALIZATI ON 20 9 E 6TH STREE T V I E W F R O M 4 0 0 B L O C K E A S T 6 T H S T R E E T L O O K I N G W E S T A U S T I N H I S T O R Y C E N T E R , c . 1 9 3 7 , A U S T I N , T E X A S PRELIMINARY - NOT FOR CONSTRUCTION | JAN 10,2024HLC REVIEW | 218 EAST 6TH STREET 218 E 6TH ST. 200 BLOCK PROPERTY SUMMARY: ADDRESS: 218 E 6TH STREET CURRENT NAME: VACANT 1975 NHRP SURVEY: 2022 MACROSTIE SURVEY: CONTRIBUTING CONTRIBUTING HISTORIC DESIGNATION: NRHD DATE BUILT: 1880s . T S S O Z A R B E 6TH ST. . T S O T N I C A J N A S View from E 6th Looking South at 218 E 6th Austin History Center, c. 1956, Austin, Texas SOUTH ELEVATION HISTORIC PHOTO (1956) CURRENT PHOTOS (2023) SITE PLAN S S E R G N O C S O Z A R B O T N I C A J N A S SIXTH STREET HISTORIC DISTRICT LEGEND P R O P E R T Y O V E R V I E W Y T I N I R T E 6 T H S E H C E N R E V I R D E R E N I B A S 5 3 - I PRELIMINARY - NOT FOR CONSTRUCTION | JAN 10,2024HLC REVIEW | 218 EAST 6TH STREET View From Corner of E 6th and San Jasinto Blvd. Looking Nortwest at 218 E 6th Austin History Center, c. 1930s, Austin, Texas View From E 6th looking Norteast at 218 E 6th Austin History Center, c. 1940s, Austin, Texas H I S T O R I C I M A G E R Y PRELIMINARY - NOT FOR CONSTRUCTION | JAN 10,2024HLC REVIEW | 218 EAST 6TH STREET View from E 6th Looking South at 218 E 6th Austin History Center, c. 1956, Austin, Texas HISTORIC PHOTOS SOUTH ELEVATION: EXISTING 2020 PROPOSED SOUTH ELEVATION S O U T H E L E V A T I O N C …

Scraped at: Jan. 13, 2024, 2:16 a.m.