CITY OF AUSTIN – PLANNING AND DEVELOPMENT REVIEW DEPARTMENT SITE PLAN APPLICATION – MASTER COMMENT REPORT CASE NUMBER: REVISION #: CASE MANAGER: SP-2014-0370C 00 Rosemary Avila UPDATE: PHONE #: U0 512-974-2784 PROJECT NAME: LOCATION: The Circle at Nelms Multi-Family Developmental Site Plan 6305 BLUFF SPRINGS RD W/BLDGS & UNITS SUBMITTAL DATE: November 3, 2014 REPORT DUE DATE: December 1, 2014 FINAL REPORT DATE: December 11, 2014 10 DAYS HAVE BEEN ADDED TO THE UPDATE DEADLINE STAFF REPORT: This report includes all staff comments received to date concerning your most recent site plan submittal. The comments may include requirements, recommendations, or information. The requirements in this report must be addressed by an updated site plan submittal. The site plan will be approved when all requirements from each review discipline have been addressed. However, until this happens, your site plan is considered disapproved. Additional comments may be generated as a result of information or design changes provided in your update. If you have any questions, problems, concerns, or if you require additional information about this report, please do not hesitate to contact your case manager at the phone number listed above or by writing to the City of Austin, Planning and Development Review Department, P.O. Box 1088, Austin, Texas 78704. UPDATE DEADLINE (LDC 25-5-113): It is the responsibility of the applicant or his/her agent to update this site plan application. The final update to clear all comments must be submitted by the update deadline, which is March 27, 2015. Otherwise, the application will automatically be denied. If this date falls on a weekend or City of Austin holiday, the next City of Austin workday will be the deadline. EXTENSION OF UPDATE DEADLINE (LDC 25-1-88): You may request an extension to the update deadline by submitting a written justification to your case manager on or before the update deadline. Extensions may be granted for good cause at the Director’s discretion. UPDATE SUBMITTALS: A formal update submittal is required. You must make an appointment with the Intake Staff (974-2689) to submit the update. Please bring a copy of this report with you upon submittal to Intake. Please submit 11 copies of the plans and 12 copies of a letter that address each comment for distribution to the following reviewers. Clearly label information or packets with the reviewer’s name that are intended for specific reviewers. No distribution is required for the Planner 1 and only …
HISTORIC LANDMARK COMMISSION APPLICATION FOR A CERTIFICATE OF APPROPRIATENESS JULY 6, 2022 HR-2022-068314 MCDONALD-MCGOWN HOUSE 1802 LAVACA STREET B.4 – 1 PROPOSAL Demolish brick wall. PROJECT SPECIFICATIONS Demolish an existing brick wall, topped with wrought iron, at the rear of the property. Remove wrought-iron gate. Do not replace. ARCHITECTURE 1802 Lavaca Street is a brick Second Empire building with a Mansard roof, built in 1876. While the wrought iron gate and trim were added in 1972 per the historic zoning application, the date of the wall is unrecorded in City permit records and certificates of appropriateness. DESIGN STANDARDS The City of Austin’s Historic Design Standards (March 2021) are based on the Secretary of the Interior’s Standards for Rehabilitation and are used to evaluate projects at historic landmarks. The following standards apply to the proposed project: Sites and streetscapes 2. Walls and fences While the design standards do not address non-street-facing walls and fences, they do prohibit covering or painting historic- age masonry site walls. Summary The project may meet the applicable standards. If the wall dates to the time of later restoration and modification of the property, demolition without replacement is within the scope of the design standards. STAFF RECOMMENDATION Approve the application. The applicant has provided information that shows the wall was constructed in the 1970s. LOCATION MAP B.4 – 2 PROPERTY INFORMATION Photos B.4 – 3 1975 image showing rear wall. Yancey, Michael D. [Historic Property, Photograph THC_07-0174], photograph, February 6, 1975; (https://texashistory.unt.edu/ark:/67531/metapth672897/m1/1/?q=%221802%20lavaca%22: accessed June 22, 2022), University of North Texas Libraries, The Portal to Texas History, https://texashistory.unt.edu; crediting Texas Historical Commission.
HISTORIC LANDMARK COMMISSION APPLICATION FOR A CERTIFICATE OF APPROPRIATENESS JULY 6, 2022 HR-2022-084176 THOMAS FAMILY HOME 1119 E. 11TH STREET B.5 – 1 PROPOSAL Repair deteriorated wood elements or replace in-kind where deteriorated beyond repair. Repair foundation, replace porch steps, and replace roof in-kind. Remove non-original additions, repair historic-age windows and doors, and replace deteriorated or non-original windows and doors. Repair porch handrail, raise porch trim, and install an ADA-compliant lift. PROJECT SPECIFICATIONS 1) Repair existing siding at north, west, and east elevations. Repair shingles at gable. Retain trim. 2) Replace corrugated metal foundation skirting with wood lattice. 3) Replace shingle roof and gutters in-kind. 4) Replace front concrete steps with wood steps. Relocate and replace steps at east elevation to accommodate ADA lift. 5) Repair existing handrail. 6) Repair and repaint existing front door. Reorient to open out. Replace non-historic door at east elevation. Add new kitchen access door and steps at west rear elevation. 7) Repair historic windows. Where deteriorated beyond repair, replace in-kind. Remove non-original window at rear addition. molding. 8) Repair porch columns. Where deteriorated beyond repair, replace in-kind. Raise trim height and remove non-original 9) Demolish non-historic water heater closet and non-original lean-to addition at east elevation. ARCHITECTURE One-story wing-and-gable house with a hipped roof and projecting gables with fish-scale shingling at tympanum and a wraparound porch supported by Doric columns. The front gable has a large window with a multi-lite transom, indicative of the Queen Anne style. DESIGN STANDARDS The City of Austin’s Historic Design Standards (March 2021) are based on the Secretary of the Interior’s Standards for Rehabilitation and are used to evaluate projects at historic landmarks. The following standards apply to the proposed project: Repair and alterations 1. General standards The proposed project repairs and stabilizes deteriorated siding, trim, windows, doors, and columns; it only replaces deteriorated elements when they are damaged beyond repair. It removes some non-original accretions that do not appear to be character-defining features of the house, though they were constructed during the historic period. 2. Foundations The proposed project stabilizes the house’s foundation and replaces the corrugated metal skirting with brick. The brick appears appropriate, provided that pier locations are articulated per Committee feedback so as not to create an unbroken masonry expanse. 3. Roofs The proposed project replaces the existing shingle roof in-kind. The proposed roofline modifications at the rear are not appropriate, as they alter an …
T H O M A S H O U S E E A S T S I D E S T R E E T FA C I N G F R O N T B A W E S T S I D E L O O K I N G S O U T H G C F W E S T S I D E L O O K I N G N O R T H A L L E Y FA C I N G S O U T H A L L E Y FA C I N G S O U T H S O U T H E A S T C O R N E R E D E X I S T I N G E X T E R I O R C O N D I T I O N S A L E T T E R D E N O T E S L O C AT I O N O N E X I S T I N G S I T E P L A N THOMAS HOUSE1119 E 11TH ST AUSTIN TX 7870210 JUNE 2022 N F O Y E R K I T C H E N B AT H R O O M L K J I M H B E D R O O M D E N ( N O T O R I G I N A L ) S I T T I N G R O O M L I V I N G R O O M E X I S T I N G I N T E R I O R C O N D I T I O N S A L E T T E R D E N O T E S L O C AT I O N O N E X I S T I N G F L O O R P L A N THOMAS HOUSE1119 E 11TH ST AUSTIN TX 7870210 JUNE 2022 F W/H 4/WEST ELEVATION N 11°24'20" E 102.28' PROPERTY LINE 5' SETBACK OH OH KITCHEN DINING ROOM LIVING ROOM N O I T A V E L E H T U O S / 3 OH E ) T A L P R E P ( Y E L L A ' …
D E T E R I O R AT I N G F O U N D AT I O N , M E TA L S K I R T AT P O R C H D E C K A N D E X P O S E D S O I L S TA C K . N O N - O R I G I N A L A LT E R AT I O N S AT D E E P E R C O V E R E D P O R C H R O O F S U P P O R T B E A M S , S H O R T E N E D C O L U M N S A N D P LY W O O D AT C O V E R E D P O R C H C E I L I N G . R E P L A C E N O N - O R I G I N A L S I D E R E F R E S H F R O N T E N T R A N C E E N T R A N C E D O O R D O O R A D D I T I O N A L E X H I B I T S THOMAS HOUSE1119 E 11TH ST AUSTIN TX 7870210 JUNE 2022
HISTORIC LANDMARK COMMISSION APPLICATION FOR A CERTIFICATE OF APPROPRIATENESS JULY 6, 2022 HR-2022-084089 BRASS-GODDARD HOUSE 1108 W. 9TH STREET B.6 – 1 PROPOSAL Repair deteriorated porch elements and windows. Reopen enclosed door opening at front porch and install door and transom. Add elevator shaft to north elevation. Replace existing rear addition, add arbor at east elevation, and renovate existing garage and guest house. PROJECT SPECIFICATIONS and wood windows. 1) Repair deteriorated porch elements, including wood columns, wood balustrade, wood frieze and trim, porch foundation, 2) Reopen enclosed opening at front porch and install a door. 3) Add elevator and elevator shaft to north façade. The proposed elevator shaft allows access to all three floors. 4) Demolish two-story addition at rear (north) elevation. Construct a new two-story addition. The proposed addition includes a screened porch connecting to the guest house. Fenestration includes fixed-glazing steel windows and doors at full and half-height. Proposed cladding includes vertical wood rainscreen and metal shingle siding. Roof materials include nonreflective paint-grip standing seam metal. 5) Install detached steel arbor at east elevation. 6) Renovate existing detached garage and guest house to match addition. ARCHITECTURE DESIGN STANDARDS Three-story limestone house designed by Jacob Larmour with Mansard roof, gabled dormers, limestone masonry cladding, second-floor veranda, widow’s walk, and wrap-around porch supported by Corinthian columns. The City of Austin’s Historic Design Standards (March 2021) are based on the Secretary of the Interior’s Standards for Rehabilitation and are used to evaluate projects at historic landmarks. The following standards apply to the proposed project: Repair and alterations 1. General standards The proposed project includes repair, rather than replacement, of historic character-defining features. The application has been amended to reopen an enclosed door using physical evidence of patching and replace it with a door, rather than with a window from the rear of the building. 2. Foundations The proposed project repairs the deteriorated foundation and pavers in-kind. 3. Roofs The proposed project removes some roof material at the rear for the installation of an elevator. 4. Exterior walls and trim The proposed project repairs deteriorated trim. The application has been amended to reopen an enclosed door using physical evidence of patching and replace it with a door, rather than with a window from the rear of the building. 5. Windows, doors, and screens The proposed project includes repair of existing windows and replacement of an infilled door and transom. 6. Porches The …
DEMO EXIST. WOOD PRIVACY FENCE CUT BACK EXISTING FLATWORK FOR NEW STONE WALL DEMO EXIST. CONC. STOOP DEMO EXIST. GARAGE ROOF DEMO EXIST. WOOD PRIVACY FENCE DEMO EXIST. STONE STOOP DEMO STEPPING STONES 6'- 2 3 /8 " 1 R EXISTING DRIVE STRIPS TO REMAIN A/C A/C A/C K C A B T E S D R A Y E D S 5 I ' SHEET IS FORMATTED TO 24" X 36". SCALES ARE ONE HALF OF NOTED WHEN PRINTED TO 12" X 18". 15' ALLEY EXIST. CONC. PARKING PAD UNDERGROUND SERVICE FROM POLE TO EM 10' REAR YARD SETBACK LOT 19 BLK.7 LOT 20 BLK.7 LINE OF EXIST. 2ND STORY ABOVE, SEE DEMO FLOOR PLAN. EXIST. ONE STORY WOOD FRAME GARAGE F.F.= 107.7' EXIST. CONC. PAD | || | || | | | | CUT BACK EXISTING FLATWORK FOR NEW STONE WALL || || || || LOT 21 BLK.7 EXIST. TWO STORY WOOD FRAME GUEST HOUSE F.F.= 106.7' I P U Q E L O O P DEMO EXIST. STONE RETAINING WALL EXIST. POOL EXIST. THREE STORY HISTORIC STONE RESIDENCE F.F.= 107.7' UP EXIST. COVERED PORCH R 9'-6" UP 25' FRONT YARD SETBACK R 9'-6" DEMO EXIST. SIDEWALK DEMO EXIST. CONC. APRON TEMPORARY BENCHMARK: TRIANGLE CUT ON CURB. ASSUMED ELEV. = 100.0' DEMO SITE PLAN 1 W. 9TH STREET (60' R.O.W.) SHEET IS FORMATTED TO 24" X 36". SCALES ARE ONE HALF OF NOTED WHEN PRINTED TO 12" X 18". UP SCALE: 3/32" = 1'-0" PLAN NORTH T RU E NO R TH EXIST. CONC. STEPS TO REMAIN UP UP LEGAL DESCRIPTION LOT 19&20 & W 4 FT OF LOT 21 BLK 7 OLT 5 DIV Z SILLIMAN SUBD E 46 FT OF LOT 21 BLK 7 OLT 5 DIV Z SILLIMAN SUBD ZONING MF-4-H-HD-NP & MF-4-HD-NP LOT SIZE 22,551 SF TREE SCHEDULE TREE # SIZE/TYPE T294 32.4" OAK T295 19" MAGNOLIA T296 19" ELM T297 9" MAGNOLIA T298 10" OAK T299 11.8" OAK T300 10.2" OAK T301 9.2" OAK T302 11.2" OAK T303 10.4" OAK 1. 2. 3. 4. 7. 8. 9. 10. 11. PROTECTED TREE NOTES: DRIP LINE CALCULATION 1'-0" PER 0'-1" OF TRUNK ALL TREES & NATURAL AREAS SHOWN ON PLAN TO BE PROTECTED DURING CONSTRUCTION WITH TEMPORARY FENCING. FENCING SHALL BE ERECTED ACCORDING TO CITY OF AUSTIN STANDARDS OF TREE PROTECTION. CONTRACTOR RESPONSIBLE FOR PERMIT APPROVAL FOR REMOVAL OF TREES WITH A DIAMETER OF 19" …
HISTORIC LANDMARK COMMISSION APPLICATION FOR A CERTIFICATE OF APPROPRIATENESS JULY 6, 2022 HR-2022-075037 HILDRETH-FLANAGAN-HEIERMAN HOUSE 3909 AVENUE G B.7 – 1 PROPOSAL Construct a swimming pool. PROJECT SPECIFICATIONS ARCHITECTURE Install a swimming pool, deck, and patio in side yard. Replace existing fence and plant privacy hedges around the pool area. The house’s 1990 National Register nomination describes it as follows: […] 2-story frame dwelling that was built in 1902. As is sometimes seen on contemporaneous houses, the dwelling retains the features of Victorian-era housing coupled with details from the Classical Revival style. The house remains virtually unaltered and is in good condition. A massive 2-story dwelling with a generally square plan, the house rests on a pier-and-beam foundation. The primary (east) facade is dominated by a 2-tier porch featuring Doric columns and turned-wood balustrades suggestive of the Classical Revival style popular in Texas during the early 20th century. A projecting 2- tiered portico a t the south end of the porch marks the entry bay. Fenestration includes a single doorway with transom and double-hung wood sash with 1/1 lights. Polygonal projecting bays on the side (north) elevation alleviate the regular massing. Along with the complex roofscape of steeply pitched hipped and gable roof forms, these features are more typica l of Victorian-er a dwellings. Interior corbelled chimneys of buff-colored brick extend from the north and south slopes of the hipped roof. Modest changes that do not adversely affect the dwelling's historic integrity include a 2- story addition on the rear (west) elevation and installation of metal awnings over the windows and the entry bay of the porch.1 DESIGN STANDARDS The City of Austin’s Historic Design Standards (March 2021) are based on the Secretary of the Interior’s Standards for Rehabilitation and are used to evaluate projects at historic landmarks. The following standards apply to the proposed project: Sites and streetscapes 1. Vegetation, topography, and landscaping 1.3 If the property had a grassy, open front lawn when constructed, maintain that context. Do not replace the lawn with paving or gravel. The proposed pool and surrounding deck and fenced area do not maintain the landmarked building’s landscape context. 2. Walls and fences 2.4 If constructing a new street-side fence or site wall, design it so that the materials, style, and scale are compatible with and differentiated from the architectural style and period of the building and are in keeping with historic fence styles …
Allen, Amber From: Sent: To: Subject: Janet Salazar <c Wednesday, June 8, 2022 11:49 AM Allen, Amber Re: 3909 Avenue G. Questions > Follow Up Flag: Flag Status: Follow up Flagged *** External Email - Exercise Caution *** Hi Amber, Attached below are photos showing the front yard and fence line as well as some inspiration photos of the privacy bushes we will be installing which will cover the view of the pool from the street. Please let me know if this works! 1
12'-6" 12'-0" 2'-11" 57'-2" 4'-9" 5'-8" 6'-4" 8'-10" 14'-6" 4'-7" 6'-11" 1'-0" NEW FENCING LINE BARK MULCH 75 SF BARK MULCH 15 SF HORIZONTAL WOOD SLAT FENCE " 4 " 4 " 4 " 4 " 4 " 4 " 1 - ' 4 " 0 - ' 3 " 7 - ' 1 " 0 - ' 2 " 0 - ' 2 " 0 - ' 2 " 0 - ' 2 " 0 - ' 2 " 2 - ' 1 " 0 1 - ' 9 " 2 - ' 1 " 0 1 - ' 9 " 1 - ' 7 RESIDENCE (E) BARK MULCH 265 SF DECOMPOSED GRANITE 200 SF BRICK PATIO AND STEPERS 240 SF CONCRETE 80 SF POOL 225 SF TIMBER TECH 250 SF BARK MULCH 675 SF DRIVEWAY (E) BARK MULCH 55 SF LIMESTONE WASHED BRICKS 500 SF BUILDING (E) NATURAL FLAGSTONE 470 SF BUILDING (E) BARK MULCH 35 SF DECOMPOSED GRANITE 210 SF STONE STEP (E) " 6 - ' 6 2 " 8 - ' 4 " 3 - ' 5 " 5 - ' 4 2 " 4 - ' 7 1 " 0 - ' 2 2 10'-7" 9'-10" 23'-0" 24'-2" 20'-3" 23'-4" 10'-8" 1'-2" 1'-2" 1 5 7 8 7 , X T , n i t s u A G e u n e v A 9 0 9 3 i e c n e d s e R n a h a l l a C DIMENSIONS + MATERIALS PLAN BACK YARD DATE: 04/19/2022 SCALE: SCALE: 1/8" = 1'-0" @ 24" x 36" sheet N SCALE: 1/8"=1'-0" 0 8' 16' ATTENTION LANDSCAPE CONTRACTOR: IF YOU HAVE QUESTIONS ABOUT THIS DESIGN, OR TO LEARN MORE ABOUT WORKING WITH YARDZEN, PLEASE CONTACT PROS@YARDZEN.COM. NOTE: PLANS ARE FOR CONCEPTUAL AND ILLUSTRATIVE PURPOSES ONLY
HISTORIC LANDMARK COMMISSION APPLICATION FOR A CERTIFICATE OF APPROPRIATENESS JULY 6, 2022 HR-2022-084891 RAYMOND-MORLEY HOUSE 510 BAYLOR STREET B.8 – 1 PROPOSAL Rehabilitate house, add guardrails to upper floors, reconstruct rear additions, add shed roofs to rear doorway. PROJECT SPECIFICATIONS 1) Repair deteriorated elements, replacing in-kind where deteriorated beyond repair, at all elevations: a. Repair original wood windows and screens. Do not replace shutters. b. Replace roof with either asphalt shingles or standing-seam metal. c. Repair fascia, frieze, scrollwork, siding, and other wood elements by consolidation, adding dutchmen, etc. Replace in-kind where deteriorated beyond repair. Repaint. d. Reconstruct deteriorated portions of rear additions where damaged beyond repair, reusing wood where possible. e. Remove paint from limestone and repair significant cracks with Cathedral Stone repair products. f. Repair damaged mortar and repaint previously painted brick only. g. Install gutters and downspouts, investigating existing internal gutter system’s viability. a. Replace upper balustrade with balustrade based on 1974 photo. Install at original height, using metal rod to achieve required code height and spacing. Remove lower gallery balustrade and regrade/replant below. 2) East (main) elevation: b. Replace stair handrail. c. Repair and repaint screen door. 3) North elevation: a. Create accessible entrance by removing stops from door. b. Remove sealant at brick joints. Remove inappropriate mortar at gable joint and repair diagonal cracking at windows. c. Reopen infilled window opening and install new wood window to match existing. 4) West (rear) elevation: a. Install salvaged rubble skirting to hide new concrete piers. b. Stabilize and fill cistern. c. Install new concrete steps with metal guards and handrails. d. Install shed roofs, supported by metal columns, over doorways. e. Install new door and security lighting. 5) South elevation a. Install new crawlspace hatch doors. b. Remove double doors and steps at rear addition, replacing with window at first floor. Replace second-floor window. c. Deconstruct stairs. Install new stairs, roof, and handrails to match west elevation. d. Replace missing soffit. e. Remove guardrail from lower porch, then regrade and replant. ARCHITECTURE From the building’s 1974 National Register nomination: Originally, the Raymond-Morley House was symmetrical across the east front with a double central door flanked by two [full-height] windows...A slight projection on the rear of the north part provided space for the original stairs. The front doors opened onto a central hall with two transomed doorways opening onto a single room on either side…The Austin buff brick, …
P U P U P U N D / / N 2 2 0 1 . 2 5 . 3 0 RAYMOND - MORLEY HOUSE REHABILITATION PROJECT ADDRESS: 510 BAYLOR AUSTIN, TEXAS 78703 PROJECT NUMBER: 202122 PROJECT ISSUE DATE: 10 JUNE 2022 LOCATION MAP CONSTRUCTION LOCATION : 2 2 1 2 0 2 R E B M U N T C E J O R P I I I N O T A T L B A H E R E S U O H Y E L R O M - D N O M Y A R INDEX OF SHEETS A001 A002 AD100 AD101 AD102 AD103 AD104 AS101 A101 A102 A103 A104 A201 A202 A402 A501 A601 S001 S002 S101 S102 S103 M000 M001 M002 M003 M101 M102 M301 M401 M402 M501 M502 M601 S104 E000 E001 E002 E003 ED101 ED102 ES101 E101 E102 E201 E202 E401 E501 E601 P000 P001 P002 PD101 PD102 P101 P102 P201 P202 P401 P501 P502 P601 ABBREVIATIONS & GENERAL NOTES ACCESSIBILTY NOTES DEMO - ARCHITECTURAL SITE DEMO - GROUND LEVEL - FLOORPLAN DEMO - LEVEL 2 - FLOORPLAN DEMO - GROUND LEVEL - RCP DEMO - LEVEL 2 - RCP ARCHITECTURAL SITE PLAN GROUND LEVEL FLOOR PLAN LEVEL 2 FLOOR PLANS GROUND LEVEL RCP LEVEL 2 RCP EXTERIOR ELEVATIONS EXTERIOR ELEVATIONS INTERIOR ELEVATIONS CONSTRUCTION DETAILS SCHEDULES AND DOOR & FRAME ELEVATIONS STRUCTURAL NOTES STRUCTURAL INSPECTION CHECKLIST FOUNDATION PLAN CEILING & FLOOR FRAMING PLAN ROOF FRAMING PLAN MECHANICAL GENERAL NOTES MECHANICAL SYMBOLS AND ABBREVIATIONS MECHANICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS MECHANICAL PLAN - GROUND LEVEL MECHANICAL PLAN - LEVEL 2 MECHANICAL SECTIONS MECHANICAL SCHEDULES MECHANICAL SCHEDULES MECHANICAL DETAILS MECHANICAL DETAILS MECHANICAL CONTROLS FOUNDATION & FRAMING DETAILS ELECTRICAL GENERAL NOTES ELECTRICAL LEGEND ELECTRICAL SPECIFICATIONS ELECTRICAL SPECIFICATIONS ELECTRICAL DEMOLITION PLAN - GROUND LEVEL ELECTRICAL DEMOLITION PLAN - LEVEL 2 ELECTRICAL SITE PLAN ELECTRICAL LIGHTING PLAN - GROUND LEVEL ELECTRICAL LIGHTING PLAN - LEVEL 2 ELECTRICAL POWER PLAN - GROUND LEVEL ELECTRICAL POWER PLAN - LEVEL 2 ELECTRICAL SCHEDULES ELECTRICAL DETAILS ELECTRICAL RISER DIAGRAM PLUMBING GENERAL NOTES PLUMBING SPECIFICATIONS PLUMBING SPECIFICATIONS PLUMBING DEMOLITION PLAN - GROUND LEVEL PLUMBING DEMOLITION PLAN - LEVEL 2 PLUMBING WASTE & VENT PLAN - GROUND LEVEL PLUMBING WASTE & VENT PLAN - LEVEL 2 PLUMBING DOMESTIC WATER PLAN - GROUND LEVEL PLUMBING DOMESTIC WATER PLAN - LEVEL 2 PLUMBING SCHEDULES PLUMBING DETAILS PLUMBING DETAILS PLUMBING RISERS PRELIMINARY NOT FOR CONSTRUCTION THIS DOCUMENT IS …