Historic Landmark CommissionNov. 2, 2022

20.0 - 1020 Spence St original pdf

Thumbnail of the first page of the PDF
Page 1 of 9 pages

20 – 1 HISTORIC LANDMARK COMMISSION PERMITS IN NATIONAL REGISTER HISTORIC DISTRICTS NOVEMBER 2, 2022 HR-2022-152879 WILLOW-SPENCE 1020 SPENCE STREET PROPOSAL Partially demolish and construct an addition to the rear side of a ca. 1912 contributing building. Construct a garage apartment at rear of lot. PROJECT SPECIFICATIONS 1) Construct a rear addition two-story addition to the existing one-story house. The addition is connected to the main house by a glass hyphen. It is clad in stack bond brick, stucco, and vertical wood siding. The roofline is mostly flat and clad in TPO, save for a small section of standing-seam metal shed roofing. Fenestration is mostly fixed, undivided, and vertically oriented. 2) Construct a two-story detached garage apartment with alley access at the rear of the lot. Proposed finishes and roofline appear to match the new addition. 3) Replace siding, windows, and roof and move the front door at the main house. Construct an accessible ramp and handrail to the front porch. The proposed window and door replacements modify original openings and window configurations. ARCHITECTURE RESEARCH One-story National Folk house with pyramidal hipped roof, board-and-batten siding, and inset partial-width porch supported by turned posts. Fenestration includes double entry doors and 1:1 wood windows. The 1985 Willow-Spence National Register Historic District nomination describes the house as “a one-story, board-and-batten cottage with a hipped roof and corner porch. Many architectural details are intact, including a Victorian comer-porch column. New elements include a cement foundation, steps, and porch floor.”1 The house at 1020 Spence was constructed around 1912 as a rental property. Its architectural details share many similarities with “Hofheinz houses,” distinctive National Folk houses rented out in East Austin to working-class families during the early years of the twentieth century by Edmund and Oscar Hofheinz. From the East Austin Context Statement (East Austin Historic Resource Survey), Vol. 1, p. I-40: The first two decades of the 1900s were rampant with development throughout the East Austin survey area …residential construction in these new developments reflected evolving trends in domestic designs, as the eclectic tastes of the Victorian era waned and simpler styles and detailing became more widespread. Among the poor and working classes, new house types began to replace more traditional forms. The linear, one‐room‐deep plans that featured gabled roofs…gave way to a new generation of houses with deeper, more box‐like plans and often had hipped or pyramidal roofs with inset porches. The effect …

Scraped at: Oct. 29, 2022, 4:53 a.m.
Historic Landmark CommissionNov. 2, 2022

20.1 1020 Spence St - drawings original pdf

Thumbnail of the first page of the PDF
Page 1 of 14 pages

GENERAL NOTES THE CONTRACTOR SHALL VERIFY AND COORDINATE SIZES, LOCATIONS AND "ALIGN" AS USED IN THESE DOCUMENTS SHALL MEAN TO ACCURATELY LOCATE ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE CODES, THE CONTRACTOR SHALL SUBMIT TO THE OWNER CONFIRMATIONS OF ORDERS, THE GENERAL CONTRACTOR AND EACH SUBCONTRACTOR SHALL BE RESPONSIBLE ALL MATERIALS FURNISHED UNDER THIS CONTRACT SHALL BE NEW UNLESS NOTED THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO THE ARCHITECT FOR APPROVAL ALL MEP RELATED ITEMS SHOULD BE REVIEWED BY THE ENGINEER AND MAY BE ADJUSTED CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY BRACING AND PROTECTING ALL THE CONTRACTOR SHALL CERTIFY SIZE AND LOCATION OF ALL REQUIRED OPENINGS FOR 1. REGULATIONS, ORDINANCES AND STANDARDS, HAVING JURISDICTION, INCLUDING APPLICABLE TEXAS LAW AND AMERICAN'S WITH DISABILITIES ACT. IF THERE ARE ANY QUESTIONS OR CONFLICTS CONCERNING COMPLIANCE WITH SUCH CODES, ORDINANCES OR STANDARDS, THE CONTRACTOR IS RESPONSIBLE FOR NOTIFYING THE ARCHITECT BEFORE PROCEEDING WITH THE WORK IN QUESTION. ALL NECESSARY LICENSES, CERTIFICATES, TESTS, ETC. SHALL BE PROCURED AND PAID FOR BY THE CONTRACTOR. ALL NECESSARY PERMITS SHALL BE PROCURED BY THE CONTRACTOR AND PAID FOR BY OWNER. 2. CONTRACTOR IS RESPONSIBLE FOR CHECKING ALL CONTRACT DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS FOR ACCURACY AND CONFIRMING THAT THE WORK IS BUILDABLE AS SHOWN AND MEETS ALL APPLICABLE CODES BEFORE PROCEEDING WITH CONSTRUCTION. IF THERE ANY QUESTIONS REGARDING THESE OR OTHER COORDINATION ISSUES, THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING WITH THE WORK IN QUESTION OR RELATED WORK. 3. STRUCTURAL, MECHANICAL, ELECTRICAL AND PLUMBING WORK AND EQUIPMENT WITH TRADES INVOLVED. 4. FOR CHECKING EXISTING CONDITIONS AT THE JOB SITE BEFORE SUBMITTING PROPOSALS. SUBMISSION OF PROPOSALS SHALL BE TAKEN AS EVIDENCE THAT SUCH INSPECTIONS HAVE BEEN MADE. CLAIMS FOR EXTRA COMPENSATION FOR WORK THAT COULD HAVE BEEN FORESEEN BY SUCH INSPECTION, WHETHER SHOWN ON CONTRACT DOCUMENTS OR NOT, SHALL NOT BE ACCEPTED OR PAID. 5. OTHERWISE. ALL WORK SHALL BE GUARANTEED AGAINST DEFECTIVE MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR AFTER THE DATE OF SUBSTANTIAL COMPLETION OR ACCEPTANCE OF THE WORK. THE CONTRACTOR SHALL REPAIR OR REPLACE, AT HIS OWN EXPENSE WHEN ORDERED TO DO SO. ALL WORK THAT MAY DEVELOP DEFECTS IN MATERIAL OR WORKMANSHIP WITHIN THE ONE YEAR TIME PERIOD. 6. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED RECOMMENDATIONS FOR SERVICE INTENDED, AS INTERPRETED BY THE ENGINEER AND ARCHITECT. THE INSTALLATION OF …

Scraped at: Oct. 29, 2022, 4:53 a.m.
Historic Landmark CommissionNov. 2, 2022

20.2 1020 Spence St - applicant presentation original pdf

Thumbnail of the first page of the PDF
Page 1 of 5 pages

A PP ROACH | NP S 1 SECRETA RY OF INT ERIOR’S STANDARDS HISTORIC BUILDINGS NEW ADDITIONS “ Placin g f un ction s a nd s erv ice s r equired for th e ne w use in n on - cha r acte r- d ef ining interior s pa ces ra th er t han ins ta ll in g a new addition. Con st ructi ng a new a dd ition s o t hat t here is th e lea s t pos s ib le los s of hist oric materials a nd s o th at ch ar acte r- def ining fe atures are not ob scur ed , d a ma ge d, or d es tr oye d. Loca ting the at tac hed ex ter ior a ddition at the re a r or on an in con sp icuous sid e of a historic b uild ing ; and limiting it s s ize a n d scale in re la tions hip to the his toric b uild ing. Des ig ning new a dd ition s in a m anner t hat make s cle ar w hat i s his toric a nd what is new.” PRE CEDENT S 1020 SPENCECONCEPTUAL DESIGN NEW ALLEY ENTRY 2 NEW GARAGE AND STUDY AP T NEW STRUCTURE SE T BACK CONNEC TION WALKWAY/ BRIDGE EXISTING HOME TO REMAIN SI TE ST UDY 1020 SPENCECONCEPTUAL DESIGN 3 EXI ST ING PH OTOS 1020 SPENCECONCEPTUAL DESIGN 4 NEW STRUCTURE SET BACK; CLADDING IN WHITE STACK BOND BRICK. EXISTING HOUSE TO REMAIN. PATCH AND MATCH ANY NEW OPENINGS TO MATCH EXITNG SIDING. EXI ST ING PH OTOS 1020 SPENCECONCEPTUAL DESIGN 5 NEW STRUCTURE SET BACK; CLADDING IN WHITE STACK BOND BRICK. NEW STRUCTURE SET BACK; CLADDING IN WOOD SIDING. FENESTRATION IN BLACK FRAMES. NEW STRUCTURE SET BACK; CLADDING IN STUCCO. FENESTRATION IN BLACK FRAMES. EXISTING HOUSE TO REMAIN. PATCH AND MATCH ANY NEW OPENINGS TO MATCH EXITNG SIDING. NEW STRUCTURE SET BACK; CLADDING IN WHITE STACK BOND BRICK. EXI ST ING PH OTOS 1020 SPENCECONCEPTUAL DESIGN

Scraped at: Oct. 29, 2022, 4:53 a.m.
Historic Landmark CommissionNov. 2, 2022

21.0 - 1907 Kenwood original pdf

Thumbnail of the first page of the PDF
Page 1 of 7 pages

HISTORIC LANDMARK COMMISSION PERMITS IN NATIONAL REGISTER HISTORIC DISTRICTS NOVEMBER 2, 2022 HR-2022-155521 TRAVIS HEIGHTS-FAIRVIEW PARK 1907 KENWOOD AVENUE 21 – 1 PROPOSAL Demolition of an existing quadplex and new construction of a duplex. PROJECT SPECIFICATIONS 1) Total demolition of a circa 1947 duplex that has been converted to a quadplex, a contributing structure to the Travis Heights National Register District. 2) New construction of an interior split-level, two-story duplex using brick, stucco, and clear sealed wood. ARCHITECTURE The structure is circa 1947 Contemporary Style brick and tile quadruplex with a flat roof. The structure is built into the hillside, initially with garage space down, like a walk-out basement plan. The Contemporary Style house typically could be built on steep hillsides where Ranches and even Split-levels would be challenging to place. The house appears to be a single story from the street, but downhill reveals a two-story structure. The fenestration seems to be original 4:5 metal frame casement windows, with a slightly recessed central entry on the front façade. The second street-level unit is accessed via a side entry door. The rear façade reveals a partial width upper and lower balcony with rear stairs for accessing the rear-facing living units. RESEARCH DESIGN STANDARDS The property first appears in the 1949 Citywide directory as rented by Marvis and Bess Bell, with Mr. Bell’s occupation listed as a “salesman.” It was followed by several other renters, such as Robert E. Rips and Nina Brewer, whose occupations were not listed. The interior was repaired and remodeled in 1960. The City of Austin’s Historic Design Standards (March 2021) are based on the Secretary of the Interior’s Standards for Rehabilitation and are used to evaluate projects in National Register districts. The following standards apply to the proposed project: Repair and alterations 1. General standards The project seeks to demolish a historic building that provides four living units and replace it with compatible new construction which will only offer two living units. Repair and rehabilitation are always recommended over demolition. Furthermore, historic housing stock is more affordable than new construction, and the project proposes demolishing four existing housing units. The replacement will be two new construction units, which will likely be less affordable than those it replaces. Residential new construction 1. Location The new construction project is sited appropriately from the street and in keeping with the rhythm of other contributing structures. 2. Orientation The project …

Scraped at: Oct. 29, 2022, 4:53 a.m.
Historic Landmark CommissionNov. 2, 2022

21.1 - 1907 Kenwood Ave - drawings & renderings original pdf

Thumbnail of the first page of the PDF
Page 1 of 10 pages

R O F T O N N O I T C U R T S N O C R O F T O N T I M R E P t c e t i h c r A s a x e T - s e n a e J y k c e B 7 9 2 1 2 # n o i t a r t s i g e R 2 2 / 3 1 / 0 1 t l t o n y a m d n a e e p m o c n i s i t n e m u c o d s i h T g n i t t i m r e p , l a v o r p p a y r o a u g e r r o f d e s u e b t l . n o i t c u r t s n o c r o t c e t i h c r A s a x e T - e a g n u o T y a r T t 9 0 5 1 2 # n o i t a r t s i g e R 2 2 / 3 1 / 0 1 t l t o n y a m d n a e e p m o c n i s i t n e m u c o d s i h T g n i t t i m r e p , l a v o r p p a y r o a u g e r r o f d e s u e b t l . n o i t c u r t s n o c r o d o o w n e K 4 0 7 8 7 X T , n i t s u A e u n e v A d o o w n e K 7 0 9 1 L A E S T C E J O R P Y B N W A R D E U S S I T E E H S n b w e i v e R C H L | 2 2 / 3 1 / 0 1 SHEET TITLE EXISTING PHOTOS SHEET A0.0 CAUTION: …

Scraped at: Oct. 29, 2022, 4:53 a.m.
Historic Landmark CommissionNov. 2, 2022

21.2 - 1907 Kenwood Ave - late revisions original pdf

Thumbnail of the first page of the PDF
Page 1 of 13 pages

R O F T O N N O I T C U R T S N O C R O F T O N T I M R E P t c e t i h c r A s a x e T - s e n a e J y k c e B 7 9 2 1 2 # n o i t a r t s i g e R 2 2 / 8 2 / 0 1 t l t o n y a m d n a e e p m o c n i s i t n e m u c o d s i h T g n i t t i m r e p , l a v o r p p a y r o a u g e r r o f d e s u e b t l . n o i t c u r t s n o c r o t c e t i h c r A s a x e T - e a g n u o T y a r T t 9 0 5 1 2 # n o i t a r t s i g e R 2 2 / 8 2 / 0 1 t l t o n y a m d n a e e p m o c n i s i t n e m u c o d s i h T g n i t t i m r e p , l a v o r p p a y r o a u g e r r o f d e s u e b t l . n o i t c u r t s n o c r o d o o w n e K 4 0 7 8 7 X T , n i t s u A e u n e v A d o o w n e K 7 0 9 1 L A E S T C E J O R P Y B N W A R D E U S S I T E E H S n b w e i v e R C H L | 2 2 / 8 2 / 0 1 SHEET TITLE EXISTING PHOTOS SHEET A0.0 CAUTION: …

Scraped at: Oct. 29, 2022, 4:56 a.m.
Historic Landmark CommissionNov. 2, 2022

22.0 - 1407 Alta Vista Ave original pdf

Thumbnail of the first page of the PDF
Page 1 of 6 pages

22 – 1 HISTORIC LANDMARK COMMISSION /PERMITS IN NATIONAL REGISTER HISTORIC DISTRICTS NOVEMBER 2, 2022 HR-2022-155536 TRAVIS HEIGHTS - FAIRVIEW PARK 1407 ALTA VISTA AVENUE PROPOSAL Remodel a ca. 1932 duplex to convert it to single-family use. Demolish a detached garage and construct a new garage apartment in its place. PROJECT SPECIFICATIONS 1) Convert duplex to single-family use. Change roofline, remove double entryways and gables, replace siding, replace windows, replace doors, replace porch. Materials include painted aluminum roofing, fiber cement siding, metal windows with wood casing and trim, and painted metal railing. 2) Demo existing garage and build new detached garage apartment. The proposed garage apartment is one and one-half stories in height, with a shed roof and fixed undivided windows. A full-height vertical screen structure accents horizontal fiber cement siding, and a round window appears at the west elevation above a concrete and wood retaining wall. A metal fence to match the main house’s porch guardrail surrounds the garage. ARCHITECTURE RESEARCH DESIGN STANDARDS Two-story Tudor Revival duplex with symmetrical plan, wood siding, and decorative steeply pitched entry gables with ornamental bargeboards, friezes, and brackets. The duplex at 1407 Alta Vista was constructed around 1932 as a rental property for Mrs. John L. Smith. Residents were mostly short-term, and included military servicemen, University of Texas students, clerks, state government employees, and hospital employees. The City of Austin’s Historic Design Standards (March 2021) are based on the Secretary of the Interior’s Standards for Rehabilitation and are used to evaluate projects in National Register districts. The following standards apply to the proposed project: Repair and alterations 1. General standards The proposed alterations remove the remaining character-defining features of the house. 3. Roofs The proposed alterations do not retain the historic roof configuration, pitch, eave detailing, decorative elements, or design. 4. Exterior walls and trim The proposed replacement siding appears appropriate. 5. Windows, doors, and screens The proposed window replacements further exacerbate the loss of material from the 2013 remodel. They do not match the size and details of the original windows in historic photographs and further alter openings. 6. Porches Though a historic photograph indicates that separate angled stairwells were original to the duplex, there is no precedent for a single angled stairwell leading to a centered entryway; the design does not appear to successfully convey its intended sympathy for the building’s historic form. Residential new construction 1. Location and 2. Orientation …

Scraped at: Oct. 29, 2022, 5:01 a.m.
Historic Landmark CommissionNov. 2, 2022

22.1 1407 Alta Vista Ave - applicant photos original pdf

Thumbnail of the first page of the PDF
Page 1 of 1 page

Backup

Scraped at: Oct. 29, 2022, 5:01 a.m.
Historic Landmark CommissionNov. 2, 2022

22.2 1407 Alta Vista Ave - materials original pdf

Thumbnail of the first page of the PDF
Page 1 of 1 page

Additional Page for Building Materials EXTERIOR FINISH MATERIALS: ROOFING - PTD ALUMINUM (BERMUDA PANEL) SIDING - CEMENT HARDI BOARD DOORS & WINDOWS - METAL FRAMED WINDOWS WITH PTD WOOD CASING/TRIM PORCH - COMPOSITE DECK, PTD METAL RAILING, PTD METAL SOFFIT PORCH STAIR - COMPOSITE STAIR TREADS, PTD METAL STRINGER, PTD METAL RAILING LANDSCAPING - GRAVEL, RESILIENT PLANTING, TIMBER STEPS, CONC. RETAINING WALL, PERMEABLE PAVING, CONC. PATHS INTERIOR FINISH MATERIALS: WALLS - PTD GWB, TILE DOORS & WINDOWS - PTD WOOD CASING/TRIM FLOOR - WHITE OAK, TILE CEILING - PTD GWB CABINETRY - WOOD COUNTERTOPS - ENGINEERED STONE BUILDING MATERIALS: WOOD FRAMING INSULATION OSB SHEATHI

Scraped at: Oct. 29, 2022, 5:02 a.m.
Historic Landmark CommissionNov. 2, 2022

22.3 1407 Alta Vista Ave - drawings original pdf

Thumbnail of the first page of the PDF
Page 1 of 15 pages

A B C D E F 1 2 3 4 5 6 7 8 9 10 GOAL: CONVERT HOME AT 1407 ALTA VISTA AVE FROM DUPLEX TO SINGLE FAMILY RESIDENCE AND RECONCILE ARTIFACTS FROM 2 PREVIOUS RENOVATIONS TO MAKE THE APPEARANCE MORE SIMPLE, HARMONIOUS AND MORE SYMPATHETIC TO THE CONTEXT OF THE NEIGHBORHOOD. WE BELIEVE THAT THE PREVIOUS RENOVATIONS WERE SIGNIFICANT ENOUGH THAT 1407 SHOULD NOT BE CONSIDERED AS A CONTRIBUTING BUILDING, HOWEVER WE STILL INTEND TO BE AS SYMPATHETIC AS POSSIBLE TO THE SCALE, FORM, AND MATERIALITY OF OUR CONTEXT. REAR ADDITION ADDED IN 2013 MAINTAIN ORIGINAL STYLE SIDING ON FRONT AND SIDES -MATCHES 1409 ROOFING TO MATCH CURRENT APPEARANCE AS CLOSELY AS POSSIBLE WHILE IMPROVING PERFORMANCE REPLACE GABLE ROOF ON REAR ADDITION WITH SHED ROOF. -MATCH CURRENT HEIGHT AND FOOTPRINT. DOOR TRIM REPLACED IN 2013 DOOR TRIM REPLACED IN 2013 PORCH REPLACED MID 1900s DOOR TRIM REPLACED IN 2013 DOOR TRIM REPLACED IN 2013 1 ORIGINAL DUPLEX, ca 1930 NTS 2 PRESENT, CONVERTED TO SINGLE FAMILY IN MID 1900s, AND BACK TO DUPLEX IN 2013 SCALE: 3/16" = 1'-0" 3 PROPOSED ALTERATIONS, 2022 SCALE: 3/16" = 1'-0" REMOVE FRONT DORMERS TO SIMPLIFY PORCH, AND BETTER MATCH NEIGHBORING HOMES. ROOF PITCH TO BE ALTERED ENABLING DEEPER EAVES TO SHADE FRONT PORCH -OWNER NOTED INSUFFICIENT HEAD-HEIGHT CLEARANCE UNDER DORMER EAVES NEW PORCH AND ENTRANCE ADDED MID 1900s FRONT WINDOWS AND DOORS APPEAR TO HAVE BEEN REPLACED IN 2013 MATCH CURRENT/NEIGHBORING SCALE OF SIDING NEW RESILIENT LANDSCAPING WITH NATIVE PLANTING REPLACE STAIR WITH SINGLE STAIR THAT MIMICS THE ORIGINAL FRONT ELEVATION OF THE HOME. METAL PORCH AND STAIR RAILINGS WILL ALSO BE MORE SIMILAR TO ORIGINAL HOME REPLACE 2013 WINDOWS WITH LARGER CASEMENT WINDOWS -MATCH ORIGINAL WINDOW TRIM SEAL SIMPLIFIED FRONT ROOF MORE SIMILAR TO THAT OF NEIGHBOR SIMPLIFIED FRONT ROOF MORE SIMILAR TO THAT OF NEIGHBOR SIMPLIFIED FRONT ROOF MAINTAINS SCALE SIMILAR TO THAT OF NEIGHBOR SIMPLIFIED FRONT ROOF MORE SIMILAR TO THAT OF NEIGHBOR 1405 ALTA VISTA AVE (NEXT DOOR) 1400 ALTA VISTA AVE (ACROSS STREET) 1409 ALTA VISTA AVE (NEXT DOOR) 1411 ALTA VISTA AVE 1413 ALTA VISTA AVE ARCHITECT: NORMAN KELLEY, INC. 53 W. JACKSON BLVD. STE 1452 CHICAGO, IL 60604 312-374-1039 WWW.NORMANKELLEY.US OWNER: RUSSELL KORTE & CARMEN-CHRISTINA KELLEHER 1407 ALTA VISTA AVE AUSTIN, TX 78704 STRUCTURAL CONSULTANT: TBD GENERAL CONTRACTOR TBD CERTIFICATION AND SEAL: I N O T A V O N E R I E …

Scraped at: Oct. 29, 2022, 5:02 a.m.
Historic Landmark CommissionNov. 2, 2022

23.0 - 1414 Westover Rd original pdf

Thumbnail of the first page of the PDF
Page 1 of 3 pages

HISTORIC LANDMARK COMMISSION PERMITS IN NATIONAL REGISTER HISTORIC DISTRICTS NOVEMBER 2, 2022 HR-2002-155175 OLD WEST AUSTIN 1414 WESTOVER RD. 23.0 – 1 PROPOSAL PROJECT SPECIFICATIONS DESIGN STANDARDS Demolish and rebuild existing non-contributing garage and make modifications to the rear of the primary house. 1) Remove existing non-contributing garage and rebuild a new one; 2) Remove existing concrete and stone driveway ribbons from the garage up to the front corner of the house; 3) Remove concrete from North corner of house The City of Austin’s Historic Design Standards (March 2021) are based on the Secretary of the Interior’s Standards for Rehabilitation and are used to evaluate projects in National Register districts. The following standards for new construction apply to the proposed project: 1. Location The new detached garage will replace the existing garage within the same footprint. The proposed replacement is appropriate. 2. Orientation The orientation of the proposed garage will match the predominant garage orientation found on the block’s contributing properties. The proposed replacement is appropriate. 3. Scale, Massing, and Height The scale, massing, and height of the proposed new construction is appropriate. 5. Design and Style The design and style of the proposed garage is appropriate. Summary The removal of the concrete and stone driveway ribbons will not affect the contributing status of the primary house. The garage to be demolished is non-contributing to the district. The project meets the applicable standards. STAFF RECOMMENDATION Comment on and release the plans. LOCATION MAP 23.0 – 2 HR 22-155175 1414 WESTOVER ROAD 1:2400 10/19/2022 This product is for informational purposes and may not have been prepared for or be suitable for legal, engineering, or surveying purposes. It does not represent an on-the-ground survey. This product has been produced by the City of Austin for the sole purpose of geographic reference. No warranty is made by the City of Austin regarding specific accuracy or completeness. Property Information Photos 23.0 – 3 1414 Westover Application, 2022

Scraped at: Oct. 29, 2022, 5:02 a.m.
Historic Landmark CommissionNov. 2, 2022

23.1 - 1414 Westover Rd - photos and drawings original pdf

Thumbnail of the first page of the PDF
Page 1 of 7 pages

DEERING RESIDENCE 1414 WESTOVER RD AUSTIN, TX 78703 ABBREVIATION KEY: A= B= C= D= E= F= G= H= ABV A/C ACOUST AC.T. ADDL A.F.F. A.H.U. ALUM APPROX ARCH ASPH BD B.L. BLDG BLK BLKG BLW BM BR BRG BTM CAB CANT C.J. C.L. CL CLG CLO CLOS CLR CMU C.O. COL COND CONC. CONT CONTR COV CPT C.T. CTR D.F. DIA DIM DISHWR DISP DN DR D.S. DTL DWG DW E EA E.J. ELEC ELEV ENAM. ENVIR. EQ EQUIP E.S.U. E.W. E.W.C. EXH EXIST EXP EXT F.D. FDN F.E. F.E.C. F.F. FIN FIXT FLEX FLR FLUOR F.R. FTG FURR GA GAL GALV G.C. GEN GL GWB GYP H. H.B. HC H.C. HD HDW H.M. HORIZ HOL HR HT HTR HVAC I= I.D. INT INSUL ABOVE AIR CONDITIONER ACOUSTICAL ACOUSTICAL TILE ADDITIONAL ABOVE FINISH FLOOR AIR HANDLING UNIT ALUMINUM APPROXIMATE ARCHITECT. ARCHITECTURAL ASPHALT BOARD BUILDING LINE BUILDING BLOCK BLOCKING BELOW BEAM BRICK BEARING BOTTOM CABINET CANTILEVER CONTROL JOINT CENTER LINE CLOSET CEILING CLOSET CLOSET CLEAR CONCRETE MASONRY UNIT CASED OPENING COLUMN CONDENSOR OR CONDUIT CONCRETE CONTINUOUS CONTRACT, CONTRACTOR COVER, COVERING CARPET CERAMIC TILE COUNTER TOP DRINKING FOUNTAIN DIAMETER DIMENSION DISHWASHER DISPENSOR DOWN DOOR, DRIVE DOWNSPOUT DETAIL DRAWING DISHWASHER EAST EACH EXPANSION JOINT ELECTRICAL ELEVATION ENAMEL ENVIRONMENT EQUAL EQUIPMENT ELECTRIC STUB-UP EACH WAY ELEC. WATER COOLER EXHAUST FAN EXISTING EXPANSION EXTENSION, EXTERIOR FLOOR DRAIN FOUNDATION FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FINISH FLOOR FINISH FIXTURE FLEXIBLE FLOOR FLUORESCENT FIRE RETARDANT FOOTING FURRING GAUGE GALLON GALVANIZED GENERAL CONTRACTOR GENERAL GLASS, GLAZING GYPSUM WALL BOARD GYPSUM HIGH HOSE BIBB HANDICAP HOLLOW CORE HEAD HARDWARE HOLLOW METAL HORIZONTAL HOLLOW HOUR HEIGHT HEATER HEATING, VENTILATION, AIR CONDITIONING INSIDE DIAMETER INTERIOR INSULATE, INSULATION M= N= O= P= Q= R= S= MAS MATL MAX MECH MED.CAB. MTL MFR MGF MIN MIR MISC M.O. MTD MTL MW M/W N NAP N.D. N.I.C. N.V. O.C. O.D. O.E. OFF OPG OPP PC PL PLAS P.LAM. PLMG PLYWD PN PNLG PNT POLY PP PROP PTD PT P.T. PVC PW QT. Q.T. QTR. R RD R.D. RE: REF REFG REINF REQD REV RM R.O. RUB S SAN S.B. SC: S.C. SCH S.D. SEC SF SHLVS SECT SHT SHTG SIM SP SPEC S/S S.S. S.T.C. STD STL STRUCT SUSP SWR TB T.B. TBD T.D. TELE THOLD TLT T.P.H. T.R. TSTAT TYP U.L. U.N.O. U.O.N. V.B. VCT VERT VEST V.W.C. T= U= V= W= W W/ MASONRY MATERIAL MAXIMUM MECHANICAL MEDICINE CABINET METAL MANUFACTURER MANUFACTURER MINIMUM …

Scraped at: Oct. 29, 2022, 5:02 a.m.
Historic Landmark CommissionNov. 2, 2022

24.0 - 210 W 6th St original pdf

Thumbnail of the first page of the PDF
Page 1 of 3 pages

24 – 1 HISTORIC LANDMARK COMMISSION PERMITS IN NATIONAL REGISTER HISTORIC DISTRICTS NOVEMBER 2, 2022 HR-2022-155454 CLAUDIA TAYLOR JOHNSON HALL (RTHL) 210 W. 6TH STREET PROPOSAL Replace roof with skylight system over lightwell, replace pavers over cellar with glass block, construct mechanical areaway, replace glazing, paint windows, install elevator shaft, add doors. PROJECT SPECIFICATIONS 1) Site: Replace non-original pavers over cellar areaway with glass block to provide additional light at basement level. Add below grade mechanical areaway to south side of building. 2) Roof: Replace non-original roof assembly over historic lightwell with a new modular skylight system. Install new elevator shaft. Replace six skylights/air intake openings. 3) Glazing: Replace glazing at select elevations with laminated, Low-E glazing. 4) Exterior Windows: The exterior windows will be repainted. Final color selection is dependent on full-size mock-ups. A historic finish analysis has been completed and will help guide the owner on color options. 5) Exterior Doors: Add two single-leaf custom steel doors at the north elevation window wall. The steel doors will be designed to match configuration of the historic steel windows. ARCHITECTURE The building’s Recorded Texas Historic Landmark marker describes the limestone temple-fronted Classical Revival post office building as follows: “Constructed during the period 1912-1914. This building was the seventh United States post office location in Austin, Texas. The supervising architect for the neo-classical revival style structure was James Knox Taylor of the U.S. Treasury Department. It was built by Dieter and Wenzel Construction Company of Wichita, Kansas, at a cost of $172,987. The land cost $40,000. Following construction of a new post office and federal building in 1965, the building was given to the University of Texas system by the Federal Government; it was remodeled into administrative offices by the university in 1970. The building was named in honor of Claudia Taylor Johnson, wife of the 36th president of the United States of America.”1 DESIGN STANDARDS The City of Austin’s Historic Design Standards (March 2021) are based on the Secretary of the Interior’s Standards for Rehabilitation and are used to evaluate projects in National Register districts. The following standards apply to the proposed project: Repair and alterations 1. General standards The proposed project removes intact historic windows and glazing and modifies openings to accommodate new fenestration. 3. Roofs The proposed project replaces non-historic roof material and skylights. Replacements do not appear visible from the street. 5. Windows, doors, and screens The …

Scraped at: Oct. 29, 2022, 7:20 p.m.
Historic Landmark CommissionNov. 2, 2022

24.1 210 W. 6th St - HR app and scope of work original pdf

Thumbnail of the first page of the PDF
Page 1 of 22 pages

Kilroy Post Office - Indeed Tower City of Austin Historic Review Application Table of Contents SITE LOCATION MAP HISTORIC DISTRICT MAP INDEX OF KEY PLANS - Basement Floor Plan - First Floor Plan - Second Floor Plan - Attic Floor Plan - Roof Plan INDEX OF PHOTOGRAPHS - Historic - Exterior - Interior - Basement - First Floor - Second Floor - Attic Floor - Roof Floor H1 to H5 E1 to E6 B1-B2 F1 to F9 S1 to S2 A1 R1 to R3 Kilroy Post Office - Indeed Tower Sixth Street Historic District Austin, TX N Kilroy Post Office - Indeed Tower Sixth Street Historic District Boundary from National Register Nomination Austin, TX BLOCK 71 NOT SHOWN FOR CLARITY, REF. ARCHITECTURE SERIES BLOCK 71 NOT SHOWN FOR CLARITY, REF. ARCHITECTURE SERIES 1 Basement Floor Plan Scale: 1/8" = 1'-0" N PLAN NORTH BLOCK 71 NOT SHOWN FOR CLARITY, REF. ARCHITECTURE SERIES OPEN TO FLOOR ABOVE DN DN 1 First Floor Plan Scale: 1/8" = 1'-0" N PLAN NORTH OPEN TO BELOW BLOCK 71 NOT SHOWN FOR CLARITY, REF. ARCHITECTURE SERIES N D 1 Second Floor Plan Scale: 1/8" = 1'-0" N PLAN NORTH BLOCK 71 NOT SHOWN FOR CLARITY. REF. ARCHITECTURE SERIES N D 1 Attic Floor Plan Scale: 1/8" = 1'-0" N PLAN NORTH BLOCK 71 NOT SHOWN FOR CLARITY, REF. ARCHITECTURE SERIES. 1 Roof Plan Scale: 1/8" = 1'-0" N PLAN NORTH Kilroy Post office | 1914 h1 | historic: south elevation shortly after comPletion Kilroy Post office | 1914 h2 | historic: north and West elevations Kilroy Post office | 1910s h3 | historic: vieW of lobby during construction Kilroy Post office | 1910s h4 | historic: vieW of mail sorting room during construction Kilroy Post office | 1910s h5 | historic: vieW of steel WindoW at north facade Kilroy Post office | 2022 e1 | exterior: south elevation, indeed toWer at right Kilroy Post office | 2022 e2 | exterior: south elevation Kilroy Post office | 2022 e3 | exterior: aerial vieW of indeed toWer With Plaza and Kilroy Post office Kilroy Post office | 2022 e4 | exterior: north elevation With indeed toWer at left Kilroy Post office | 2022 e5 | exterior: north elevation steel WindoWs Kilroy Post office | 2022 e6 | exterior: south elevation, main entry Kilroy Post office | 2022 b1 | basement: vieW of basement level Kilroy Post office …

Scraped at: Oct. 29, 2022, 7:20 p.m.
Historic Landmark CommissionNov. 2, 2022

24.2 210 W. 6th St - drawings original pdf

Thumbnail of the first page of the PDF
Page 1 of 20 pages

KILROY 100 FIRST STREET, SUITE 250 SAN FRANCISCO, CA 94105 Page Project No. 121070 HISTORIC REVIEW SUBMISSION 14 OCTOBER 2022 THE POST 210 West 6th Street Austin, TX 78701 Page Southerland Page, Inc. 400 W. Cesar Chavez Street Fifth Floor Austin, TX 78701 pagethink.com TEL FAX 512 472 6721 512 477 3211 ARCHITECTURE / ENGINEERING / INTERIORS / PLANNING / CONSULTING Austin / Dallas / Denver / Houston / San Francisco / Washington DC / International Affiliate Offices DESIGN ARCHITECT ROCKWELL GROUP 5 UNION SQUARE WEST NEW YORK, NY 10003 212-463-0334 STRUCTURAL ENGINEER THORNTON TOMASETTI 804 LAS CIMAS PKWY SUITE 140 AUSTIN, TX 78746 512-580-1750 MEP ENGINEER BLUM CONSULTING 8144 WALNUT HILL LANE SUITE 200 DALLAS, TX 75231 214-373-8222 AUDIOVISUAL CONSULTANT DIMENSIONAL INNOVATIONS 3421 MERRIAM DR OVERLAND PARK, KS 66203 913-384-3488 ARCHITECT OF RECORD PAGE SOUTHERLAND PAGE 400 W CESAR CHAVEZ ST SUITE 500 AUSTIN, TX 78701 512-382-3527 LIGHTING CONSULTANT SEAN O'CONNOR LIGHTING 12955 W WASHINGTON BLVD LOS ANGELES, CA 90066 310-659-5900 TECHNOLOGY/SECURITY 4B TECHNOLOGY 390 GLENBOROUGH DR HOUSTON TX 77067 832-249-9379 HISTORIC CONSULTANT ARCHITEXAS 2900 S. CONGRESS AVE SUITE 200 AUSTIN, TX 78704 512-444-4220 ARCHITECTURAL SUPPORT MCKINNEY YORK ARCHITECTS 1301 E. 7TH ST AUSTIN TX 78702 512-476-0201 ACOUSTICAL CONSULTANT IDIBRI 15508 WRIGHT BROTHERS DR ADDISON, TX 75001 972-239-1505 FOOD SERVICE CONSULTANT NEXT STEP DESIGN 913 WEST ST ANNAPOLIS, MD 21401 410-263-1200 LANDSCAPE ARCHITECT CO'DESIGN 1200 YAUPON VALLEY RD AUSTIN, TX 78746 512-423-1298 t v r . L A R T N E C - 2 2 R - O P K - A 0 7 0 1 2 1 / e c i f f O : E M A N R E S U t s o P y o r l i K - 0 7 0 1 2 1 / / : s c o D k s e d o t u A : E M A N E L I F 8 4 : 5 5 : 1 1 2 2 0 2 / 3 1 / 0 1 : P M A T S E T A D M P 2 2 0 2 R E B O T C O 4 1 0 7 0 1 2 1 r e b m u N t c e j o r P e g a P T S O P E H T SYMBOL MATCHLINE SEE XX/X-XXX DESCRIPTION MATCH LINE SHEET REFERENCE 1 …

Scraped at: Oct. 29, 2022, 7:20 p.m.
Historic Landmark CommissionNov. 2, 2022

25.0 - 2212 Windsor original pdf

Thumbnail of the first page of the PDF
Page 1 of 6 pages

HISTORIC LANDMARK COMMISSION PERMITS IN NATIONAL REGISTER HISTORIC DISTRICTS / DEMOLITION AND RELOCATION PERMITS NOVEMBER 2, 2022 HR-2022-156152 OLD WEST AUSTIN 2212 E. WINDSOR 25.0 – 1 PROPOSAL Alterations to circa 1937 residential structure. PROJECT SPECIFICATIONS 1) Converting the covered porch and above balcony to conditioned space (front of house). -glass, screen wall, and concrete 2) Expand existing planters, modifying front porch steps. -glass, screen wall & concrete 3) Partially converting covered wood deck space to conditioned space (side of house) – (1st story living room and second story exercise room)- wood, glass, and brick 4) Demolishing the current recessed front entry & walls. ARCHITECTURE 2212 E. Windsor is a two-story masonry residential construction with a flat roof and symmetrical façade with central, recessed entry. The home was modified with replacement windows, doors, significant first and second-story additions, and a balcony circa 2004. RESEARCH DESIGN STANDARDS Initial research into historical associations includes Paul Bolton, an Austin news commentator and politician circa 1946 who lived at the property. The City of Austin’s Historic Design Standards (March 2021) are based on the Secretary of the Interior’s Standards for Rehabilitation and are used to evaluate projects in National Register districts. The following standards apply to the proposed project: Repair and alterations 1. General standards The project seeks to demolish and construct a new front entryway as well as demolish a rear portion of a side wall. City- wide Design Guidelines encourage repair over replacement. However, the property appears to have been significantly altered and, therefore, would no longer qualify for historic landmarking due to a lack of historic integrity. 1.1 Do not remove intact historic material from the exterior of a building. 1.2 Always attempt repair first. Replacement should only be undertaken when absolutely necessary and for the smallest area possible. 1.3 When historic material must be replaced due to damage or deterioration, replacement materials should look the same, perform reliably within the existing construction, and, in most cases, be made of the same material. 1.5 When demolishing additions or features that were built after the building’s period of significance, minimize damage to the building. a. Stabilize and repair building walls that are exposed when non-historic additions or features are removed. b. Avoid demolition that removes historic structural systems or compromises the structural integrity of a historic building. 4. Exterior walls and trim Exterior walls should be repaired rather than replaced to minimize …

Scraped at: Oct. 29, 2022, 7:22 p.m.
Historic Landmark CommissionNov. 2, 2022

25.2 - 2212 E. Windsor - photos original pdf

Thumbnail of the first page of the PDF
Page 1 of 5 pages

Backup

Scraped at: Oct. 29, 2022, 7:22 p.m.
Historic Landmark CommissionNov. 2, 2022

25.3 2212 E. Windsor - drawings original pdf

Thumbnail of the first page of the PDF
Page 1 of 14 pages

(cid:51)(cid:53)(cid:50)(cid:39)(cid:56)(cid:38)(cid:40)(cid:39)(cid:3)(cid:37)(cid:60)(cid:3)(cid:36)(cid:49)(cid:3)(cid:36)(cid:56)(cid:55)(cid:50)(cid:39)(cid:40)(cid:54)(cid:46)(cid:3)(cid:54)(cid:55)(cid:56)(cid:39)(cid:40)(cid:49)(cid:55)(cid:3)(cid:57)(cid:40)(cid:53)(cid:54)(cid:44)(cid:50)(cid:49) # DATE DESCRIPTION 01 2022.xx.xx xxxxxxxxxxx CHK X 2212 East Windsor Rd Design Set DRAWING LIST ARCHITECTURAL (cid:44) (cid:3) (cid:3) (cid:49) (cid:50) (cid:54) (cid:53) (cid:40) (cid:57) (cid:55) (cid:49) (cid:40) (cid:39) (cid:56) (cid:55) (cid:54) (cid:46) (cid:54) (cid:40) (cid:39) (cid:50) (cid:55) (cid:56) (cid:36) (cid:49) (cid:36) (cid:60) (cid:37) (cid:39) (cid:40) (cid:38) (cid:56) (cid:39) (cid:50) (cid:53) (cid:51) (cid:3) (cid:3) (cid:3) (cid:51)(cid:53)(cid:50)(cid:39)(cid:56)(cid:38)(cid:40)(cid:39)(cid:3)(cid:37)(cid:60)(cid:3)(cid:36)(cid:49)(cid:3)(cid:36)(cid:56)(cid:55)(cid:50)(cid:39)(cid:40)(cid:54)(cid:46)(cid:3)(cid:54)(cid:55)(cid:56)(cid:39)(cid:40)(cid:49)(cid:55)(cid:3)(cid:57)(cid:40)(cid:53)(cid:54)(cid:44)(cid:50)(cid:49) OWNER KEY PLAN KEY PLAN SEAL & SIGNATURE (cid:3) (cid:3) (cid:3) (cid:51) (cid:53) (cid:50) (cid:39) (cid:56) (cid:38) (cid:40) (cid:39) (cid:37) (cid:60) (cid:36) (cid:49) (cid:36) (cid:56) (cid:55) (cid:50) (cid:39) (cid:40) (cid:54) (cid:46) (cid:54) (cid:55) (cid:56) (cid:39) (cid:40) (cid:49) (cid:55) (cid:57) (cid:40) (cid:53) (cid:54) (cid:50) (cid:49) (cid:3) (cid:3) (cid:44) inca architecture pllc 1 RANDOLPH PLACE ROLLINGWOOD, TX 78746 2212 E Windosr Rd. AUSTIN, TX 78703 COVER PAGE, DRAWING LIST & PLANS PROJECT NO. 2209 JC SCALE (22x34) N.T.S. A-000.00 PAGE NO. 01 OF # DATE DESCRIPTION 01 2022.xx.xx xxxxxxxxxxx CHK X OWNER KEY PLAN KEY PLAN SEAL & SIGNATURE inca architecture pllc 1 RANDOLPH PLACE ROLLINGWOOD, TX 78746 2212 E Windosr Rd. AUSTIN, TX 78703 SURVEY PROJECT NO. 2209 JC SCALE (22x34) N.T.S. A-002.00 PAGE NO. 01 OF # DATE DESCRIPTION 01 2022.xx.xx xxxxxxxxxxx CHK X OWNER KEY PLAN KEY PLAN SEAL & SIGNATURE inca architecture pllc 1 RANDOLPH PLACE ROLLINGWOOD, TX 78746 2212 E Windosr Rd. AUSTIN, TX 78703 EXISTING PLAN GROUND FLOOR PROJECT NO. 2209 X-101.00 SCALE (22x34) 1/4" = 1'-0" PAGE NO. 10 OF # DATE DESCRIPTION 01 2022.xx.xx xxxxxxxxxxx CHK X OWNER KEY PLAN KEY PLAN SEAL & SIGNATURE inca architecture pllc 1 RANDOLPH PLACE ROLLINGWOOD, TX 78746 2212 E Windosr Rd. AUSTIN, TX 78703 EXISTING PLAN SECOND FLOOR PROJECT NO. 2209 X-102.00 SCALE (22x34) 1/4" = 1'-0" PAGE NO. 10 OF # DATE DESCRIPTION 01 2022.xx.xx xxxxxxxxxxx CHK X OWNER KEY PLAN KEY PLAN SEAL & SIGNATURE inca architecture pllc 1 RANDOLPH PLACE ROLLINGWOOD, TX 78746 2212 E Windosr Rd. AUSTIN, TX 78703 EXISTING PLAN ROOF PLAN PROJECT NO. 2209 X-103.00 SCALE (22x34) 1/4" = 1'-0" PAGE NO. 10 OF # DATE DESCRIPTION 01 2022.xx.xx xxxxxxxxxxx CHK X OWNER KEY PLAN KEY PLAN SEAL & SIGNATURE inca architecture pllc 1 RANDOLPH PLACE ROLLINGWOOD, TX 78746 2212 E Windosr Rd. AUSTIN, TX 78703 DEMOLITION PLAN GROUND FLOOR PROJECT NO. 2209 D-101.00 SCALE (22x34) 1/4" = 1'-0" PAGE NO. 10 OF # DATE DESCRIPTION 01 2022.xx.xx xxxxxxxxxxx CHK X OWNER KEY PLAN KEY PLAN SEAL & SIGNATURE inca architecture pllc 1 …

Scraped at: Oct. 29, 2022, 7:22 p.m.
Historic Landmark CommissionNov. 2, 2022

26.0 - 308 Congress Ave original pdf

Thumbnail of the first page of the PDF
Page 1 of 5 pages

HISTORIC LANDMARK COMMISSION PERMITS IN NATIONAL REGISTER HISTORIC DISTRICTS NOVEMBER 2, 2022 HR-2022-156263 CONGRESS AVENUE 308 CONGRESS AVENUE 26. – 1 Construct a new tower addition to the W. B. Smith Building and adjacent historic age buildings. PROPOSAL PROJECT SPECIFICATIONS ARCHITECTURE DESIGN STANDARDS Commercial additions 1. Location Reconstruct the street-facing east façade and demolish the remainder of the building to accommodate the new tower. Construct a new mixed-use tower set back 15 feet. Two-part commercial block with dentil ornamentation, corbelled accents, and decorative pilasters on the first floor. Balanced storefront with central door flanked by transom windows on the first floor with 2:2 arched hooded windows above. A small ground-floor entrance door provides access to upper the upper floors located on the far right (as viewed from the street) of the composition of the street-facing façade. The City of Austin’s Historic Design Standards (March 2021) are based on the Secretary of the Interior’s Standards for Rehabilitation and are used to evaluate projects in National Register districts. The following standards apply to the proposed project: 1.1 Locate additions at the rear and sides of historic buildings to minimize visual impact. 1.2 Set back additions from the front wall at a distance that preserves the perceived massing of the historic building, considering the pedestrian view from the opposite side of the primary street. a. Additions must be set back at least 20’ from the front wall of the historic building. 1.3 Minimize the loss of historic fabric by connecting additions to the existing building through the most noninvasive location and methods. 1.4 Additions are not appropriate for all historic landmarks and will be evaluated on a case-by-case basis. The addition is located at the rear of the property and is setback initially 15 feet from the historic façade, which the proposed project deconstructs and reconstructs. However, there is a total loss of fabric in all other locations, including the rear and side walls. 2. Scale, massing, and height 2.1 Design the addition to complement the scale and massing of the historic building. 2.2 Design the addition to appear subordinate to the historic building. 2.3 Minimize the appearance of the addition from the primary street(s). The historic building’s overall shape as viewed from the opposite side of the primary street must appear relatively unaltered. 2.4 Additions are subject to a 20’ setback. They may be cantilevered 5’ towards the front wall, but may …

Scraped at: Oct. 30, 2022, 9:50 a.m.
Historic Landmark CommissionNov. 2, 2022

27.0 - 310-314 Congress Ave original pdf

Thumbnail of the first page of the PDF
Page 1 of 5 pages

HISTORIC LANDMARK COMMISSION PERMITS IN NATIONAL REGISTER HISTORIC DISTRICTS NOVEMBER 2, 2022 HR-2022-156263 CONGRESS AVENUE 310-314 CONGRESS AVENUE 27. – 1 Construct a new tower addition to the W. B. Smith Building and adjacent historic age buildings. Reconstruct the street-facing east façade and demolish the remainder of the building to accommodate the new tower. Construct a new mixed-use tower set back 15 feet. Two-part commercial block with three separate storefronts. Details include dentil ornamentation at the cornice, recessed entryways, and arched 4:4 windows on the upper floor of 310-312. Historic awnings appear to have been removed, and a new awning was installed at 310. The City of Austin’s Historic Design Standards (March 2021) are based on the Secretary of the Interior’s Standards for Rehabilitation and are used to evaluate projects in National Register districts. The following standards apply to the proposed project: PROPOSAL PROJECT SPECIFICATIONS ARCHITECTURE DESIGN STANDARDS Commercial additions 1. Location 1.1 Locate additions at the rear and sides of historic buildings to minimize visual impact. 1.2 Set back additions from the front wall at a distance that preserves the perceived massing of the historic building, considering the pedestrian view from the opposite side of the primary street. a. Additions must be set back at least 20’ from the front wall of the historic building. 1.3 Minimize the loss of historic fabric by connecting additions to the existing building through the most noninvasive location and methods. 1.4 Additions are not appropriate for all historic landmarks and will be evaluated on a case-by-case basis. The addition is located at the rear of the property and is setback initially 15 feet from the historic façade, which the proposed project deconstructs and reconstructs. There is total fabric loss in all other locations, including the rear and side walls. The setback does not meet the minimum standard of 20 feet from the front wall of the historic building. 2. Scale, massing, and height 2.1 Design the addition to complement the scale and massing of the historic building. 2.2 Design the addition to appear subordinate to the historic building. 2.3 Minimize the appearance of the addition from the primary street(s). The historic building’s overall shape as viewed from the opposite side of the primary street must appear relatively unaltered. 2.4 Additions are subject to a 20’ setback. They may be cantilevered 5’ towards the front wall, but may not extend closer than 15’ behind …

Scraped at: Oct. 30, 2022, 9:50 a.m.