All documents

RSS feed for this page

Historic Landmark CommissionFeb. 5, 2025

05.1 - 810 W 11th St - Site Plan original pdf

Thumbnail of the first page of the PDF
Page 1 of 2 pages

TRAVIS COUNTY, TEXAS T. J. CHAMBERS SURVEY, A-7 ALTA/NSPS LAND TITLE SURVEY W/ TREES 0.153 ACRE (6,678 SF) OF LAND, BEING A PORTION OF OUTLOT 5, DIVISION "E" OF THE GOVERNMENT OUTLOTS ADJOINING THE ORIGINAL CITY OF AUSTIN, TRAVIS COUNTY, TEXAS, ACCORDING TO THE PLAT ON FILE AT THE GENERAL LAND OFFICE OF THE STATE OF TEXAS D R A V E L U O B K E E R A L C O H S WEST 12TH STREET SITE E U N E V T A S E W WEST 11TH STREET VICINTY MAP (NOT TO SCALE) A NATIONAL ASSOCIATION OF SOCIAL VOL. 10078, PG. 19 R.P.R.T.C.T. CALLED 0.555 ACRE TDC WEST TWELFTH LP DOC. #2019150413 O.P.R.T.C.T. 0 20 40 SCALE: 1" = 20' UTILITY AND IMPROVEMENT NOTE: ONLY SURFACE EVIDENCE OF UTILITIES AND IMPROVEMENTS ARE SHOWN ON THIS SURVEY. BEARING BASIS & HORIZONTAL DATUM: TEXAS COORDINATE SYSTEM, GRID NAD '83 (CENTRAL ZONE 4203) PORTION OF OF OUTLOT 5, DIVISION "E" 809 WEST 12TH STREET LLC DOC. #2019185329 O.P.R.T.C.T. (S70° 26'E 46') S73° 13' 42"E 46.00' OHE OHE ASPHALT PP OHE (S70° 26'E 50') S73° 13' 42"E 50.00' // FROM WHICH A PINCHED 1/2" IRON PIPE FOUND BEARS S73° 13' 42"E, 0.49' NG FROM WHICH A 1/2" IRON ROD FOUND BEARS S15° 39' 19"E, 0.23' E H O BRICK PARKING [CALLED 0.405 ACRE] CJI PROPERTIES INC. VOL. 11554, PG. 1380 R.P.R.T.C.T. / / / / / / / / / / / / / / 0.5' CONC. CURB ASPHALT PARKING 0.5' CONC. CURB 1851 E H O 1850 E H O 4.7' 18.1' ' 1 . 8 0.3' ' 1 . 8 EM 12.4' 10.9' 1849 / / AC ) ' 2 . 5 4 1 W ° 9 1 S ( ] ' 2 2 . 5 4 1 ' W 6 0 ° 9 1 S [ ' 2 1 . / / 5 4 1 E " 1 5 ' 8 0 ° 6 1 N / / NG / / ' 5 . 9 3 0.153 ACRE 6,678 SF A 5 . 9 3 ' 1-STORY BRICK BUILDING ' 1 0 . 5 4 1 W " 2 5 ' 6 0 ° 6 1 S ) ' 5 0 . 5 4 1 E ° 9 1 N ( T L A H P S A Y A W E V R D I …

Scraped at: Jan. 31, 2025, 11:50 p.m.
Historic Landmark CommissionFeb. 5, 2025

05.2 - 810 W 11th St - Previous Presentation original pdf

Thumbnail of the first page of the PDF
Page 1 of 13 pages

810 W 11th Street Historic Landmark Commission September 4, 2024 1 Site Aerial Improvement: •Constructed: Circa 1938 •Age: Approx. 86-years-old •Use: Office 2 Street View 3 Side View 4 Rear View 5 City of Austin Historic Designation Criteria A property must meet at least two of the below criteria: i. Architecture ii. Historical Associations iii. Archeology iv. Community Value v. Landscape Feature 6 Request We respectfully request your approval for the release of the demolition permit upon completion of a City of Austin Documentation Package. 7 8 1935 Sanborn Map 9 1961 Sanborn Map 10 1938 Water Service Permit 11 Neighborhood Character 810 1938 808 Cir. 1910 806 Cir. 1920 821 Cir. 1907 819 ½ Cir. 1915 819 Cir. 1925 817 Cir. 1917 813 Cir. 1917 12 Neighborhood Character 13

Scraped at: Jan. 31, 2025, 11:50 p.m.
Historic Landmark CommissionFeb. 5, 2025

06.0 - 1908 Kenwood Ave original pdf

Thumbnail of the first page of the PDF
Page 1 of 5 pages

HISTORIC LANDMARK COMMISSION PERMITS IN NATIONAL REGISTER HISTORIC DISTRICTS FEBRUARY 5, 2025 PR-2024-149032 TRAVIS HEIGHTS-FAIRVIEW PARK HISTORIC DISTRICT 1908 KENWOOD AVENUE 6.0 – 1 PROPOSAL Enclose carport and construct a second-story addition. PROJECT SPECIFICATIONS Construct an enclosure of the existing carport located at the west side of the building, which will house a screened porch and two car garage. This enclosure will slightly expand the footprint to the west, but existing exterior cladding is to be retained. The upper-floor addition will be located within the area of new construction and will project above the peak of the existing roof. ARCHITECTURE RESEARCH DESIGN STANDARDS This 1934 house is described in the Travis Heights-Fairview Park National Register as being asymmetrical in plan and having no overarching stylistic influences. The façade is clad on all sides in buff and tan brick, with wood fascia and gable ends. Due to local elevation, the house reads as one-story from Mariposa Street and two-stories from Kenwood Avenue. On the latter façade, a second-floor porch is present that spans two thirds of the façade, with a projecting ground-floor gable at the right. A front entry is located on the Mariposa Street elevation, which is fronted by a winding walkway from the street. As a whole, the house retains good integrity and not much alteration is apparent. After being constructed in 1934, the house at 1908 Kenwood Avenue was owned by Earl and Caroline Howell. They raised their daughter Carolyn in the house, where she graduated from the University of Texas. By the 1960s, they had moved out and Mr. and Mrs. J.K. Green owned the house, where they welcomed a daughter of their own. There is little known information about what line of work these owners did during these years. The City of Austin’s Historic Design Standards (March 2021) are based on the Secretary of the Interior’s Standards for Rehabilitation and are used to evaluate projects in National Register districts. The following standards apply to the proposed project: Residential additions 1. Location By using existing covered carport space, the enclosed addition is located in an area to one side of the house, towards the rear alley. Its visual impact is minimized by using this location, as recommended by Standard 1.1. However, the addition adds a story to the building at the front wall, which is not a recommended location per Standard 1.3, though the upper-story addition is …

Scraped at: Jan. 31, 2025, 11:51 p.m.
Historic Landmark CommissionFeb. 5, 2025

06.1 - 1908 Kenwood Ave - Photos original pdf

Thumbnail of the first page of the PDF
Page 1 of 8 pages

Backup

Scraped at: Jan. 31, 2025, 11:51 p.m.
Historic Landmark CommissionFeb. 5, 2025

06.2 - 1908 Kenwood Ave - Drawings original pdf

Thumbnail of the first page of the PDF
Page 1 of 17 pages

CRZ 1/2 CRZ 1/4 CRZ Existing overhead power and power-pole PORTION 3 PORTION 2 PORTION 1 S 66° 10' 5" W 139.87' (140') " E 0 4 ' 3 0 d 0 1 ' < N 8 0 . 7 @ 5 Full CRZ 1/2 CRZ 1/4 CRZ 105: Pecan Trunk Diameter: 22" 104: Chinese Pistache Trunk Diameter: 18" 5' SIDE YARD SETBACK Proposed new pole mounted meter and underground service to house per 12/12/2023 A.E. Criteria Manual, Figure 1-15A pg. 149. . e . u . e . u Existing overhead electric to existing meter. 4' construction fence NOTE: 1 roof overhang parallel to ridges for all locations. 8" roof overhang for all gable locations. o.e. ) ' 0 5 ( Full CRZ 17'-9 3/4" o.e. Proposed new exterior panel. u.e. " 2 - ' 6 1 S E R U T C U R T S R O F K C A B T E S . . E U P . ' 5 , . 7 S L O O P R O F K C A B T E S E N L R E W O P D N A K C A B T E S I . . L B S S E C C A R A E R ' 0 1 o.e. " 6 - ' 6 2 ' 7 9 . 9 1 1 W " 5 4 6 4 ° 4 2 N ' K C A B T E S . . E U P . ' 5 R 6 ' - 0 " Y E L L A I E D W ' 5 1 o.e. o.e. o.e. ) ' 0 7 ( o.e. o.e. SYM. SITE LEGEND IRON ROD FOUND SPINDLE FOUND SILT FENCE CONSTRUCTION FENCE PROPERTY LINE SETBACK LINE EASEMENT LINE / PUE ELEVATION CONTOUR LINE OE/UE OVERHEAD ELECTRIC POWER POLE ELECTRICAL METER AND BASE WATER METER W W POTABLE WATER LINE (APPROXIMATED) GP GRINDER PUMP LOCATION SS SANITARY SEWER / WASTE WATER LINE POLAR NORTH SPOT ELEVATION POINT BENCHMARK ELEVATION 3" ELEVATION CHANGE W/ DIMENSION EXISTING TREE (SEE 'TREE LIST') EXISTING TREE LIST TAG SPECIES / CONDITION / REMOVE SIZE 100 101 102 103 104 105 RED OAK / GOOD / NO RED OAK / GOOD / NO PECAN / GOOD / NO RED OAK / GOOD / NO CHINESE PISTACHE / GOOD / …

Scraped at: Jan. 31, 2025, 11:51 p.m.
Historic Landmark CommissionFeb. 5, 2025

07.0 - 705 West Lynn St original pdf

Thumbnail of the first page of the PDF
Page 1 of 5 pages

HISTORIC LANDMARK COMMISSION PERMITS IN NATIONAL REGISTER HISTORIC DISTRICTS /DEMOLITION AND RELOCATION PERMITS FEBRUARY 5, 2025 PR-2024-159632; GF-2024-161879 WEST LINE NATIONAL REGISTER HISTORIC DISTRICT 705 WEST LYNN STREET 7.0 – 1 PROPOSAL Demolish a ca. 1895 house. ARCHITECTURE The house located at 705 West Lynn Street is a single-story, center passage house with a side gabled roof set at a moderate- to-high pitch. The single front door is centered on the house with one 2/2 window on either side. There is a front porch that extends across the entirety of the front façade, supported by four columns. Due to the elevation of the site, the porch sits nearly at grade towards the front of the lot, but at the rear of the property is a full height unconditioned crawlspace or basement. While the footprint of the building may read as a simple rectangular center hall design, the rear extends further back into the lot, including an enclosed porch. There is also a small frame shed on the site, which is also proposed to be demolished. The shed is not mentioned in the West Line National Register nomination. RESEARCH From its construction around 1895 until 1962, the property was owned by the Quick family. John Quick, a carpenter originally from Sweden, was the first listed owner, and later married a woman named Helen, who was also a first-generation Swedish immigrant. Newspaper records indicate that Helen’s sister immigrated to Texas around 1893, though it is unknown whether the sisters arrived together or separately. The Quicks were involved with the local Methodist Church, with the address on West Lynn hosting a circle of the Women’s Society of Christian Service. John Quick died of natural causes in 1945, and Helen occupied the house until her passing in 1962 at the age of 91. The house was left unoccupied for several years after, but by the 1970s, it was occupied by renters. PROPERTY EVALUATION The property contributes to the West Line National Register district, and the nomination further lists the property as eligible for individual listing in the National Register of Historic Places. Designation Criteria—Historic Landmark 1) The building is more than 50 years old. 2) The building appears to retain high-to-moderate integrity. 3) Properties must meet two criteria for landmark designation (LDC §25-2-352). Staff has evaluated the property and determined that it does not meet two criteria: a. Architecture. The building is a good …

Scraped at: Jan. 31, 2025, 11:52 p.m.
Historic Landmark CommissionFeb. 5, 2025

07.1 - 705 West Lynn St - Photos original pdf

Thumbnail of the first page of the PDF
Page 1 of 9 pages

Backup

Scraped at: Jan. 31, 2025, 11:52 p.m.
Historic Landmark CommissionFeb. 5, 2025

08.0 - 1804 Brackenridge St Bldg 2 original pdf

Thumbnail of the first page of the PDF
Page 1 of 3 pages

8 – 1 HISTORIC LANDMARK COMMISSION PERMITS IN NATIONAL REGISTER HISTORIC DISTRICTS FEBRUARY 5, 2025 PR-2025-000069; HR-2025-003964 TRAVIS HEIGHTS-FAIRVIEW PARK NATIONAL REGISTER HISTORIC DISTRICT 1804 BRACKENRIDGE STREET PROPOSAL Construct a second dwelling unit behind the existing house. PROJECT SPECIFICATIONS The proposed two-story dwelling unit is located at the rear (west) of the property and accessed via the alley. It is clad in stucco and vertical wood siding and has a flat roof at the first floor and a low-slope hipped roof at the second. A second- story balcony overlooking the front elevation features simple metal guardrails. Fenestration includes undivided fixed windows at semi-regular intervals at all elevations except for the south, and fully glazed doors at all balcony and ground- floor entrances. DESIGN STANDARDS The City of Austin’s Historic Design Standards (March 2021) are based on the Secretary of the Interior’s Standards for Rehabilitation and are used to evaluate projects in National Register districts. The following standards apply to the proposed project: Residential new construction 1. Location The proposed new unit is located at the rear (west side) of the property, behind the main contributing house. 2. Orientation The proposed two-story dwelling unit is accessed via the alley. 3. Scale, massing, and height Though the new building is two stories in height, its location at the back of the lot and low-profile roofline mitigate the height difference between the main house and the new rear unit. Its floor heights appear somewhat aligned with the main house, and the design features wall-plane offsets that appear to reduce the visual weight of its massing at the main elevation. However, the lack of stepback at the Brackenridge elevation may make it appear monolithic if it is visible from the street. 4. Proportions The proposed new building’s proportions are mostly compatible. 5. Design and style The proposed new building’s design is mostly compatible, though horizontal wood siding would be more appropriate than vertical. 6. Roofs The simple low-slope rooflines appear compatible. 7. Exterior walls See 5. 8. Windows and doors Proposed fenestration is mostly compatible, though adding windows at the Brackenridge elevation would increase transparency and offset the potential for a monolithic appearance from the main street. 10. Chimneys The proposed boxed chimney does not meet the standards. 11. Attached garages and carports The proposed attached garage is oriented toward the alley, appropriately for the district. Summary The project mostly meets the applicable standards. …

Scraped at: Jan. 31, 2025, 11:52 p.m.
Historic Landmark CommissionFeb. 5, 2025

08.1 - 1804 Brackenridge St Bldg 2 - Drawings original pdf

Thumbnail of the first page of the PDF
Page 1 of 11 pages

1804 BRACKENRIDGE ST, AUSTIN, TX 78704 PERMIT 22 DECEMBER 2024 1402 W N LOOP BLVD, AUSTIN, TX 78756 DAVEY@DAVEYMARCH.COM 512-599-0660 PROJECT NO: DM230502 SHEET INDEX: A100 SITE PLAN A110 FLOOR 01 REFERENCE PLAN A112 FLOOR 01 RCP A120 FLOOR 02 REFERENCE PLAN A122 FLOOR 02 RCP A130 ROOF PLAN A200 EXTERIOR ELEVATIONS A600 SCHEDULES A700 VISITABILITY EXHIBIT A703 TREE PROTECTION PLAN A704 TREE PROTECTION PLAN/DETAILS UNIT 02 FLOOR 01 HEATED: FLOOR 02 HEATED: 560 SF 640 SF TOTAL HEATED: 1200 SF 1-CAR GARAGE: 246 SF UNIT 01 (EXISTING) FLOOR 01 HEATED: 1300 SF BUILDING COVERAGE: 2416 SF TOTAL IMPERVIOUS COVERAGE ON LOT : 2670 SF TOTAL IMPERVIOUS ALLOWED: 2837.7 SF PROJECT TEAM: ARCHITECT DAVEY MCEATHRON ARCHITECTURE 1402 W N LOOP BLVD AUSTIN, TEXAS 78756 TEL. (512) 599-0660 STRUCTURAL SEC SOLUTIONS 407 FORREST ST. LIBERTY HILL, TX, 78642 TEL. (512) 215-4364 SURVEY HOLT CARSON 1904 FORT VIEW AUSTIN, TX, 78704 TEL. (512) 442-0990 4 0 7 8 7 X T , I N T S U A , I T S E G D R N E K C A R B 4 0 8 1 I U D A E G D R N E K C A R B CONSTRUCTION NOTES: • • NO TAP PLAN REQUIRED PER AUSTIN WATER UPGRADE WATER METER FROM 5/8" TO 3/4" THROUGH AUSTIN WATER ©2024 DAVEY MCEATHRON ARCHITECTURE 22 DECEMBER 2024 REVISIONS NO REFERENCE ISSUED TIE INTO EXISTING PRIVATE WASTE WATER LINE EXISTING 2-STORY DWELLING UNIT (NEIGHBOR) S 72° 07' 35" 140.05' E HVAC HVAC E E E E E E E E E E E E E E E E E E E E E E E E E E E E E / " 8 5 6 - ' 7 / " 4 3 0 - ' 0 3 / " 4 3 0 - ' 6 K C A B T E S R A E R ' 5 E " 0 0 ' 0 0 ° 9 1 N ' 8 6 . 3 4 576' - 0" Y E L L A " 0 - ' 9 . C N O C W E N N O R P A " 0 - ' 3 " 0 - ' 3 " 0 - ' 3 CONCRETE DRIVEWAY D A E H R E V O E V A E . C N O C I O T A …

Scraped at: Jan. 31, 2025, 11:52 p.m.
Historic Landmark CommissionFeb. 5, 2025

09.0 - 1807 W 30th St original pdf

Thumbnail of the first page of the PDF
Page 1 of 5 pages

HISTORIC LANDMARK COMMISSION PERMITS IN NATIONAL REGISTER HISTORIC DISTRICTS FEBRUARY 5, 2025 HR-2025-003360 OLD WEST AUSTIN NATIONAL REGISTER HISTORIC DISTRICT 1807 WEST 30TH STREET 9.0 – 1 PROPOSAL Construct two residential units. PROJECT SPECIFICATIONS After a previous approval to demolish a property listed as non-contributing to the Old West Austin Historic District, the applicant is seeking to construct two housing units on the property. Both units are two-stories, with the rear unit including a garage accessed from the side via Oakmont Boulevard. Front and side setbacks are at similar distances to the previously demolished house. DESIGN STANDARDS The City of Austin’s Historic Design Standards (March 2021) are based on the Secretary of the Interior’s Standards for Rehabilitation and are used to evaluate projects in National Register districts. The following standards apply to the proposed project: Residential new construction 1. Location Setbacks nearly match those of the previous house and are very similar to other buildings in the district. Specifically, the rhythm of the new construction fits with the surrounding contributing buildings. Standard 1.3 calls for accessory buildings to follow historic setbacks and locations. While the second structure proposed at this property is a full second housing unit, it does conform to the standard. 2. Orientation The property is located on a street corner, with the new house facing the same street (West 30th Street) as the previous house. The rear house will be accessed from the side street, but this access is to be located at the rear of the property. 3. Scale, massing, and height Houses in this section of the district are generally single-story in height. However, numerous new construction has been approved, including immediately across the street, which is two stories in height. However, the northwest corner of the proposed front house, which comprises half of the footprint of this unit, will be a single story. This is a section of the property that is most noticeable from a distance, so it conforms to the standards. The rear unit is subordinate in height and footprint to the front unit, which satisfies Standard 3.6. 4. Proportions As mentioned in the section above, the front unit includes a two-story and a one-story section. The one-story section is compatible with the dimensions of original houses in the district, and the two-story section is more in common with recent infill and new construction. While not ideal in meeting the Standards, this …

Scraped at: Jan. 31, 2025, 11:52 p.m.
Historic Landmark CommissionFeb. 5, 2025

09.1 - 1807 W 30th St - Photos original pdf

Thumbnail of the first page of the PDF
Page 1 of 1 page

View from W30th St. Elevation from Oakmont Blvd. Rear view from Oakmont Blvd. January 9, 2025 1807 West 30th StreetMurray Legge Architecture LLC

Scraped at: Jan. 31, 2025, 11:53 p.m.
Historic Landmark CommissionFeb. 5, 2025

09.2 - 1807 W 30th St - Drawings original pdf

Thumbnail of the first page of the PDF
Page 1 of 8 pages

TAG NO. 1112 1113 1114 1115 1116 1117 SPECIES PECAN CEDAR ELM CEDAR ELM CEDAR ELM CEDAR ELM CEDAR ELM DIA. 16" 19.5" 21.5" 14.5" 20.5" 14" TREE TABLE STATUS Existing Existing Existing To Be Demolished Existing Existing PROTECTION NOTES Protected Protected Protected TREE CALCULATIONS #1113: FULL CRZ AREA = 1,194.59 SF TOTAL DISTURBED AREA WITHIN CRZ = 322.47 SF PERCENTAGE OF DISTURBED CRZ = 26.99% #1114: FULL CRZ AREA = 1,452.20 SF TOTAL DISTURBED AREA WITHIN CRZ = 59.24 SF PERCENTAGE OF DISTURBED CRZ = 4.08% #1116: FULL CRZ AREA = 1,320.25 SF TOTAL DISTURBED AREA WITHIN CRZ = 352.52 SF PERCENTAGE OF DISTURBED CRZ = 26.7% TREE NOTES IF HEAVY EQUIPMENT WILL BE ROLLING OVER ANY AERA OF THE FULL CRZ OF PROTECTED TREES, PROVIDE 3/4" PLYWOOD OVER 2X4 LUMBER OVER 12" LAYER OF MULCH TO BRIDGE OVER ROOT AND PREVENT SOIL/ ROOT COMPACTION. AFTER CONSTRUCTION IS COMPLETED, SPREAD MULCH AROUND SITE TO LEACE A MAX. LAYER OF 3" WITHIN ROOT ZONES. NO FOUNDATION FORMWORK OR BATTER BOARDS STAKES ALLOWED WITHIN THE 1/2 CRITICAL ROOT ZONE (CRZ) OF PROTECTED TREES. NO FORMWORK PERMITTED IN THE 1/4 CRZ. TRENCHING NOTES ANY TRENCHING FOR UNDERGROUND UTILITIES WITHIN THE 1/2 CRZ OF PROTECTED TREES MUST BE AIR SPADED. AVOID 1/2 CRZ IF POSSIBLE. EXISTING END OF CURB LOT AREA SUMMARY SITE LEGEND LOT SIZE Maximum FAR (55% 2 Unit) Maximum Impervious Cover (45%) 11,360.00 Sq Ft 6,248.00 Sq Ft 5,112.00 Sq Ft PROPOSED Proposed FAR (TOTAL) - Proposed FAR Unit 1 - Proposed FAR Unit 2 Proposed Impervious Cover 6,227.93 Sq Ff 4,529.50 Sq Ff 1,698.43 Sq Ft 5,039.78 Sq Ft PROPERTY LINE WATER LINE WASTE WATER LINE GAS LINE OVERHEAD ELECTRIC UNDERGROUND ELECTRIC TREE PROTECTION FENCE CO WM GM EM TO BE DEMOLISHED CLEANOUT WATER METER GAS METER ELECTRIC METER 1117 EXISTING GATE 7 8 5 8 8 5 R 5'-1 1/2" 1/4 CRZ 1116 128.44' N 54° 12' 40" E EXISTING FENCE TREE PROTECTION FENCE R 10'-3" 1/2 C R Z R 2 0 ' - 6 " F U L L C R Z 12'-0" SIDE/STREET SETBACK OAKMONT BLVD (50'-0" ROW) EXISTING END OF CURB EXISTING EDGE OF PAVEMENT INLET EXISTING WASTEWATER TAP 9 8 5 0 9 5 1 9 5 2 9 5 1112 PROPOSED GRADING K C E D D O O W CARPORT EXISTING GAS METERS GM GM INLET CONCRETE DRIVEWAY 3 9 5 …

Scraped at: Jan. 31, 2025, 11:53 p.m.
Historic Landmark CommissionFeb. 5, 2025

10.0 - 2600 E Martin Luther King Jr Blvd original pdf

Thumbnail of the first page of the PDF
Page 1 of 16 pages

HISTORIC LANDMARK COMMISSION DEMOLITION AND RELOCATION PERMITS FEBRUARY 5, 2025 DA 2024-165526; GF-2024-165917 2600 EAST MARTIN LUTHER KING, JR. BOULEVARD 10 – 1 PROPOSAL ARCHITECTURE RESEARCH Demolish a ca. 1972 auxiliary hospital building to construct a new mixed-use development. The Capital Area Research and Radiation Center building is a one-story Mid-century Modern health service facility designed by Page, Southerland, and Page and constructed by J. C. Evans Co. The building is horizontally oriented, with a dramatic carport extension at the Martin Luther King Jr. Boulevard elevation and a largely windowless street presence. It is concrete with applied stucco. Concrete walls seven feet thick and ceilings four feet thick were engineered to shield physicians and technicians from the radiation equipment within. Holy Cross Hospital, the first hospital to allow Black doctors in Austin, was originally constructed on East 11th Street in 1940 to address the burgeoning disparity in care between black and white hospitals in segregation-era Austin. It was relocated to East 19th Street—now Martin Luther King, Jr., Boulevard—in 1951. The new hospital was designed by Charles Henry Page, who would later help to found Page, Southerland, and Page.1 Though the main hospital was demolished in 1991 and replaced by Campbell Elementary School, its site received a Texas Historical Commission marker in 2021, an effort spearheaded by historian and Rogers-Washington-Holy Cross resident Berri McBride. “At the time,” recounts McBride in an interview with WhatOnceWas.org, “it was the only major hospital where African Americans could receive medical services that were affordable. But at the same time, the services provided by the hospital were complete, they were thorough, and they were first rate provided by superb doctors, including African American doctors.”2 As desegregation slowly took hold in the city, Holy Cross further distinguished itself as a progressive establishment by earning grants for new hospital buildings, innovative treatments, and cutting-edge equipment. In 1965, Page, Southerland, and Page designed the hospital’s iconic five-story circular nursing facility. The separate cancer center, operated by the Capital Area Research and Radiation Foundation and also designed by Page, was approved for installation five years later following the approval of federal funding for a regional radiation facility in Austin. The new cancer center, first called the Regional Research and Radiation Center and then renamed Capital Area Research and Radiation Center, was selected to house Central Texas’s first cobalt-60 radiotherapy device and a linear accelerator designed to treat deep tumors with …

Scraped at: Jan. 31, 2025, 11:56 p.m.
Historic Landmark CommissionFeb. 5, 2025

10.1 - 2600 E Martin Luther King Jr Blvd - Updated Presentation original pdf

Thumbnail of the first page of the PDF
Page 1 of 18 pages

2600 E Martin Luther King Jr Boulevard Historic Landmark Commission 1/8/2025 1 Project Site 2 Holy Cross Hospital 3 Existing Structure Existing Structure Landmark Designation Criteria LDC 25-2-352: 1. The property must be 50 years old and must represent a period of significance of at least 50 years ago; and 2. The property must retain a high degree of integrity, as defined by the National Register of Historic Places, that clearly conveys its historical significance and does not include an addition or alteration which has significantly compromised its integrity. Landmark Designation Criteria The property must meet at least two of the below criteria: i. Architecture ii. Historical Associations iii. Archaeology iv. Community Value v. Landscape Feature i. Architecture ARCHITECURE CRITERIA: √ Embodies the distinguishing characteristics of a recognized Staff Report: architectural style, type, or method of construction; × Exemplifies technological innovation in design or construction; × Displays high artistic value in representing ethnic or folk art, architecture, or construction; × Represents a rare example of an architectural style in the city; × Serves as an outstanding example of the work of an architect, builder, or artisan who significantly contributed to the development of the city, state, or nation; × Possesses cultural, historical, or architectural value as a particularly fine or unique example of a utilitarian or vernacular structure; or × Represents an architectural curiosity or one-of-a-kind building. “Mid-century Modern design by Page, Southerland and Page, however, its context as part of a larger hospital campus is gone” ii. Historical Associations HISTORICAL CRITERIA: The property has long-standing significant associations with persons, groups, institutions, businesses, or events of historic importance which contributed significantly to the history of the city, state, or nation; or represents a significant portrayal of the cultural practices or the way of life of a definable group of people in a historic time. • Holy Cross Hospital (established in 1940) was the first hospital to allow Black doctors in Austin • The site received a Texas Historical Commission marker in 2021, however the main hospital has been demolished. • Original Holy Cross Hospital site on 12th St has marker. ii. Historical Marker – 1610 E 11th St. iv. Community Value COMMUNITY CRITERIA: The property has a unique location, physical characteristic, or significant feature that contributes to the character, image, or cultural identity of the city, a neighborhood, or a particular group. • Holy Cross Hospital history is the basis …

Scraped at: Jan. 31, 2025, 11:56 p.m.
Historic Landmark CommissionFeb. 5, 2025

10.2 - 2600 E Martin Luther King Jr Blvd - Survey original pdf

Thumbnail of the first page of the PDF
Page 1 of 1 page

TRACT 1: LOT 2, HOLY CROSS NORTH, A SUBDIVISION IN TRAVIS COUNTY, TEXAS, ACCORDING TO THE MAP OR PLAT THEREOF, RECORDED IN VOLUME 89, PAGE 13 OF THE PLAT RECORDS OF TRAVIS COUNTY, TEXAS. | JOB NO: 15628 TRACT 2: EASEMENT ESTATE AS CREATED AND DEFINED BY EASEMENT AGREEMENT DATED FEBRUARY 20, 1990, RECORDED IN VOLUME 11127, PAGE 1006 OF THE REAL PROPERTY RECORDS OF TRAVIS COUNTY, TEXAS, AND AMENDED BY DRAWN: RDG VOLUME 11499, PAGE 1016, OF SAID REAL PROPERTY RECORDS, AND BEING OVER AND ACROSS LOT. 1, HOLY CROSS NORTH, A SUBDIVISION IN TRAVIS COUNTY, TEXAS, ACCORDING TO THE MAP OR PLAT THEREOF, RECORDED IN VOLUME 89, PAGE 13 OF THE PLAT RECORDS OF TRAVIS COUNTY, TEXAS. F.C... CC/JT I T 3: RIGHT OF WAY EASEMENT AS CREATED AND DEFINED BY EASEMENT AGREEMENT DATED AUGUST 9, 1991, RECORDED IN VOLUME 11499, PAGE 1036 OF THE REAL PROPERTY RECORDS OF TRAVIS COUNTY, TEXAS, AND BEING A 0.067 ACRE TRACT OUT OF LOT 1, HOLY CROSS NORTH, A SUBDIVISION IN TRAVIS COUNTY, TEXAS, ACCORDING TO THE MAP OR PLAT THEREOF, RECORDED IN VOLUME 89, PAGE 13 OF THE PLAT RECORDS OF TRAVIS COUNTY, TEXAS. LOT 1 LEGEND HOLY CROSS NORTH . ® 1/27 IRON ROD NO CAP FOUND VOLUME 89, PAGE 13, (UncEss OTHERWISE NOTED) 1/2" IRON ROD SET W/PLASTIC Scale: 17 = 30’ P.R.T.C. < CAP STAMPED "TLS INC.” FENCE POST BEARINGS CITED HEREON BASED ON oh Try SOLE TEXAS STATE PLANE COORDINATE « GUY ANCHOR SYSTEM, NORTH AMERICAN DATUM PAVED PARKING LOT : ——XX~—| CHAIN LINK FENCE 1983/93, TEXAS CENTRAL ZONE. Elmo ELECTRIC 4 TELEPHONE LINES omic | DEED RECORDS OF TRAVIS o 10° WIDE WASTEWATER LINE EASEMENT COUNTY, TEXAS IL = TL VOLUME 11127, PAGE 999 & - oprrc.| OFFICIAL PUBLIC RECORDS OF ; ro Nh VOLUME 11499, PAGE 1018, R.P.R.T.C. a. C1 TRAVIS COUNTY, TEXAS // ‘ Me = orc. | PLAT RECORDS OF TRAVIS 3/8" IRON ROD FOUND _| COUNTY, TEXAS ya WALL RECORD INFORMATION AIR_CONDITIONER ELECTRIC GAS METER LIGHT POLE LIGHT MANHOLE SIGN (EXPLAIN) HANDICAP PARKING SIGN IRON FENCED COVERED AREA CONC. CURB PUMP PIAL) TRANSFORMER GENERATOR WATER METER WATER VALVE CONC. | CONCRETE ROW. | RIGHT-OF-WAY N orto lee : A "SCHOOL ZONE” IRON FENCED COVERED AREA 1.3" 1.0" 8. 1.3" Pr ro ot , . 4 4 - k£d b 24 148 S\N DETAIL "A CONC. WALL & 1.0" 3 Scale: 17 …

Scraped at: Jan. 31, 2025, 11:56 p.m.
Historic Landmark CommissionFeb. 5, 2025

10.a - 2600 E Martin Luther King Jr Blvd - public comment original pdf

Thumbnail of the first page of the PDF
Page 1 of 2 pages

From: To: Subject: Date: Historic Preservation Office Against Review Case DA 24-165526 Monday, December 30, 2024 2:14:19 PM You don't often get email from . Learn why this is important External Email - Exercise Caution Dear Sam Fahnestock, I am writing to submit comments for the Historic Landmark Commission, regarding Review Case DA 24-165526 for the commission's consideration in advance of the January 8, 2025 meeting when this case will be discussed. I am a resident living within 500 feet of 2600 E. MLK Jr Blvd., which is the subject of DA 24-165526. I am AGAINST the proposed demolition of this building, which is the last surviving structure associated with the Holy Cross Hospital, the city’s first hospital for Black patients that was recently granted a historical marker through the Texas Historic Commission's Undertold Markers program (https://austin.towers.net/marking-the-medical-history-of-east-austin-at-holy-cross- hospital/). Preservation of this structure would honor the significant cultural history that it represents, while also building on the efforts of the immediately adjacent Rogers Washington Holy Cross Historic District in demonstrating the determination and success of the African American community in Austin. I am also concerned about broader plans for the development of this property following demolition, as this permit is one part of a proposal that involves converting the property from civic to mixed use zoning, including density bonuses (Zoning case C14-2024-0111 / Plan Amendment case NPA-2024-0008.01). The preservation of this structure would maintain a street-facing scale and style that is compatible with and complimentary to the adjacent historic residential neighborhoods, as well as other historically significant structures along this stretch of MLK, including David Chapel Missionary Baptist Church, the Della Phillips House, and Fuller-Sheffield Funeral Home--all located less than 500 feet on either side of the property, and characterized by horizontal massing and low slung roofs similar to the style of this structure. Maintaining the stylistic features of the surrounding area at this particular, prominent corner is important and meaningful for this community's and our city's identity. Thank you for your attention to these concerns and consideration of protecting this culturally and historically significant structure. Sincerely, Bridget Ground 1806 Cedar Avenue CAUTION: This is an EXTERNAL email. Please use caution when clicking links or opening attachments. If you believe this to be a malicious or phishing email, please report it using the "Report Message" button in Outlook. For any additional questions or concerns, contact CSIRT at "cybersecurity@austintexas.gov".

Scraped at: Jan. 31, 2025, 11:56 p.m.
Historic Landmark CommissionFeb. 5, 2025

10.b - 2600 E Martin Luther King Jr Blvd - public comment original pdf

Thumbnail of the first page of the PDF
Page 1 of 2 pages

From: To: Subject: Date: Historic Preservation Office Case DA 24-165526 Demolition -Support for Demolition Monday, January 6, 2025 8:29:02 AM You don't often get email from . Learn why this is important External Email - Exercise Caution Attn: San Fahnestock I am writing to express my support for the proposed demolition of the property located at 2600 E Martin Luther King. . As a property owner at 2503 E MLK], I believe that the removal of this structure would greatly benefit our community for several reasons: 1. Safety Concerns : The current state of the building poses significant safety risks to the neighborhood. It has become a site for illegal activities, and its dilapidated condition could lead to accidents or injuries. 2. Aesthetic and Property Values : The property detracts from the aesthetic appeal of our neighborhood. Demolition would not only improve the visual environment but potentially increase property values for surrounding homes by removing an eyesore. 3. Urban Development : The demolition would open up opportunities for new development or green space, which could revitalize the area. This could align with broader urban planning goals such as increasing community spaces or supporting new housing projects. 4. Health and Environmental Issues : There might be health hazards associated with the current state of the building, such as mold, pests, or asbestos. Demolition would address these issues, ensuring a healthier environment for residents. 5. Community Sentiment : From discussions within the community, there seems to be a general consensus that this property should be removed. This move would be in line with the community's wishes for a cleaner, safer, and more vibrant neighborhood. Please consider this letter as my formal endorsement for the demolition of the property at 2600 E Martin Luther King Jr. BLVD. I would appreciate being kept informed about the decision and any public meetings where this matter will be discussed. Thank you for your attention to this important matter. I look forward to seeing positive changes in our community. Sincerely, Lynn Morris Lynden Communities LLC 512-698-2129 CAUTION: This is an EXTERNAL email. Please use caution when clicking links or opening attachments. If you believe this to be a malicious or phishing email, please report it using the "Report Message" button in Outlook. For any additional questions or concerns, contact CSIRT at "cybersecurity@austintexas.gov".

Scraped at: Jan. 31, 2025, 11:56 p.m.
Historic Landmark CommissionFeb. 5, 2025

10.c - 2600 E Martin Luther King Jr Blvd - public comment original pdf

Thumbnail of the first page of the PDF
Page 1 of 2 pages

From: To: Cc: Subject: Date: Fahnestock, Sam Heimsath, Ben - BC Fw: 2600 E. MLK Jr. Blvd Application for Demolition and Re-Zoning Wednesday, January 8, 2025 8:31:10 AM External Email - Exercise Caution Please share with other commissioners. Thank you. R ----- Forwarded Message ----- From: patricia calhoun < To: Roxevans < Cc: patricia calhoun < Sent: Tuesday, January 7, 2025 at 10:46:14 PM CST Subject: 2600 E. MLK Jr. Blvd Application for Demolition and Re-Zoning > > > Dear Commissioner, I am writing to ask that more time be allowed for discussion and conference with the developer on this project. Our Historic District just received images today and time is needed to consider the project. This project has great ramifications to our Historic District, and we are very concerned about granting demolition permits and re-zoning before concerns are addressed: It is adjacent to an elementary school; height of building will impact the elementary What is the number of units planned, amount of parking, entrances and exits? Have environmental studies been completed? What will the impact be on well established entities like the funeral home, hospice facility and the Rogers- Washington-Holy Cross Historic District? So many concerns that have not been given time to discuss. Please do Not allow this project to move forward with demolition and re-zoning. Thank you, Patricia Calhoun, RID, IIDA, ASID, CLIPP Patricia Calhoun, RID, IIDA, ASID, CLIPP THE PERFECT ADDITION 2401 Givens Avenue Austin TX 78722 972-814-6543 (Cell) “We may have all come on different ships, but we are in the same boat now” Martin Luther King, Jr. CAUTION: This is an EXTERNAL email. Please use caution when clicking links or opening attachments. If you believe this to be a malicious or phishing email, please report it using the "Report Message" button in Outlook. For any additional questions or concerns, contact CSIRT at "cybersecurity@austintexas.gov".

Scraped at: Jan. 31, 2025, 11:56 p.m.
Historic Landmark CommissionFeb. 5, 2025

11.0 - 8401 Hathaway Dr - Burnet Middle School original pdf

Thumbnail of the first page of the PDF
Page 1 of 21 pages

11 – 1 HISTORIC LANDMARK COMMISSION DEMOLITION AND RELOCATION PERMITS FEBRUARY 5, 2025 DA-2024-088952; GF-2024-147530 8401 HATHAWAY DRIVE PROPOSAL ARCHITECTURE Demolish a ca. 1952 school and associated outbuildings. A 1960 Statesman article describes architect J. Roy White’s design for Burnet Middle School, then Lanier Junior High School, in detail: The sprawling, modern school will contain 49 teaching stations…on a 25-acre site, properly oriented for adequate cross- ventilation in all areas. A feature of the plan involves the gymnasium stage which can be viewed from [the] interior…or from a large outdoor courtyard…classroom areas can be locked off making it accessible for school and community use at night. An off-street driveway…allows students to be discharged under covered passageways…the administrative office is centrally located with the cafeteria and gymnasium on one side and three classroom wings on the other. These parallel wings are connected by covered walkways which create four courtyards. The first of the classroom wings is two-storied…the design of the school is contemporary with the exterior red face brick with aluminum windows and doors…The sloping, gabled roof was designed to give the school a homelike feeling, blending with the residential neighborhood.1 RESEARCH As Austin’s postwar population swelled and suburban neighborhoods crept northwards during the mid-twentieth century, new schools were required for the next generation of Northwest Austinites. This demographic and development change ushered in a new wave of Modern designs by innovative architects taking advantage of new technologies and design sensibilities, often on sprawling new campuses. David G. Burnet Junior High School, originally Sidney Lanier Junior High School, was designed by noted Austin architect J. Roy White during his tenure at Kuehne, Brooks, and Barr (later Brooks, Barr, Graeber, and White). Cottingham and Hale Engineers completed the structural design, and B. L. McGee was the general contractor. The school was contracted by AISD in 1960 and was initially intended to house both junior and senior high school students until a larger school could be built to relieve crowded McCallum High. When Lanier High School, designed by Fehr and Granger, was completed in 1966, 8401 Hathaway Drive became Burnet Junior High. Primary architect J. Roy White graduated from the University of Texas in 1929 and practiced in Austin until his retirement in the 1980s. White’s work often focused on institutional and civic buildings: he designed the original Austin Public Library in 1933 as part of Kuehne, Brooks, and Barr, and worked for …

Scraped at: Jan. 31, 2025, 11:56 p.m.
Historic Landmark CommissionFeb. 5, 2025

11.1 - 8401 Hathaway Dr - Burnet Middle School - Site Plan original pdf

Thumbnail of the first page of the PDF
Page 1 of 6 pages

1 2 3 4 5 A B C D E F BURNET MIDDLE SCHOOL p u o r G R L D © 8421 HATHAWAY DRIVE AUSTIN, TX 78757 PROJECT #: 230015-BURNT AUSTIN INDEPENDENT SCHOOL DISTRICT 4000 S IH 35 FRONTAGE RD, 4TH FLOOR AUSTIN, TX 78704 CMD PHONE #: (512) 414-8940 ISSUANCE: HISTORIC SITE PLAN EXEMPTION HISTORIC REVIEW ONLY: OCTOBER 14, 2024 PROJECT SCOPE: As part of the 2022 Bond, Burnet Middle School will receive a full modernization of the existing campus at its current location. The modernization of Burnet Middle School will involve a full campus replacement on its current site at 8401 Hathaway Drive, Austin, TX 78757. The design of the site will feature updated parking, site circulation, outdoor learning spaces, and outdoor athletics spaces. The future Burnet Middle School will be a medium-sized middle school, designed for an 1100-1300 student capacity at a programmed size of 248,000 GSF. The existing middle school demolition will occur after the construction of the new school has reached completion. SHEET INDEX: GENERAL G0.01: HISTORIC REVIEW COVER SHEET CIVIL 16: DEMOLITION PLAN ARCHITECTURE AD1.10: LEVEL 01 - DEMOLITION PLAN AD2.10: ENLARGED DEMOLITION PLAN A AD2.20: ENLARGED DEMOLITION PLAN B AD2.30: ENLARGED DEMOLITION PLAN C PROJECT SITE 1 VICINITY MAP G0.01 NO SCALE I I N O T A Z N R E D O M L O O H C S E L D D M T E N R U B I 7 5 7 8 7 X T , I I N T S U A E V R D Y A W A H T A H 1 2 4 8 I I T C R T S D L O O H C S T N E D N E P E D N I I N T S U A 4 0 7 8 7 X T , I N T S U A R O O L F H T 4 D R E G A T N O R F 5 3 H I S 0 0 0 4 T N R U B - 5 1 0 0 3 2 0 4 9 8 - 4 1 4 ) 2 1 5 ( HISTORIC SITE PLAN EXEMPTION 2024.10.10 REVISIONS 39-23159-00 HISTORIC REVIEW COVER SHEET G0.01 B C E A NOTES: 1. TREE PROTECTION FENCING IS REQUIRED FOR ALL TREES WITHIN THE LIMITS OF …

Scraped at: Jan. 31, 2025, 11:57 p.m.
Historic Landmark CommissionFeb. 5, 2025

11.2 - 8401 Hathaway Dr - Burnet Middle School - Photos original pdf

Thumbnail of the first page of the PDF
Page 1 of 21 pages

1 2 3 4 5 5.2 6 7 7.2 8 8.2 9 9.2 10 10.2 11 12 12.2 13 13.2

Scraped at: Jan. 31, 2025, 11:58 p.m.
Historic Landmark CommissionFeb. 5, 2025

11.a - 8401 Hathaway Dr - Burnet Middle School - public comment original pdf

Thumbnail of the first page of the PDF
Page 1 of 2 pages

Backup

Scraped at: Jan. 31, 2025, 11:58 p.m.
Historic Landmark CommissionFeb. 5, 2025

07.a - 705 West Lynn St - OWANA Letter original pdf

Thumbnail of the first page of the PDF
Page 1 of 1 page

Steering Committee Members: Steve Amos, Chair Renae Alsobrook, Mark Ashby, Evelyn Fujimoto, Adrienne Goldsberry, Paula Hern, Nick Mehl, William Osborn, Charlie Rice, Paul Shattuck, Shawn Shillington, Erika Tatum, Meghan Yancy February 3, 2025 RE: 705 West Lynn - PR-2024-159632; GF-2024-161879 Dear Chair Heimsath and HLC Commissioners, Old West Austin Neighborhood Association, OWANA, supports retaining contributing structures in our historic district and integrating existing building forms into the overall project for new development. In the case of 705 West Lynn, preserving the façade and front rooms of the existing house and adding on to the structure would have a significant impact toward that goal. The applicant met with the OWANA zoning committee and we suggested these two options for maximizing the square footage for two living units: 1. Add a second floor to a garage structure. 2. Remove a portion or all of the heritage tree on the lot to allow for a second unit. This particular case is one that is to decide on keeping a heritage tree or a contributing structure. OWANA will support the position of keeping the contributing structure. We hope that HLC can also recommend keeping the structure. We are aware that the city tree ordinance regarding heritage trees is very strict, it seems to us in this case that if both OWANA and the HLC supports this position there is the possibility of the city arborist accepting this solution. The potential Owner in today’s meeting said that he could keep the first 15 ft of the house and make the project work if the heritage tree in the back of the lot could be removed. The tree is so close to the rear structure that it might be damaged during construction. It could be the case that some mitigation is require to offset this lost. The United States Department of the Interior National Park Service Report “NATIONAL REGISTER OF HISTORIC PLACES REGISTRATION FORM” lists 705 West Lynn as a representative property to illustrate “the broad patterns of development, diverse range of resources, and salient features of the dominant types and styles present in the district. They have been selected on the basis of their geographic distribution, relationship to similar properties, and degree of integrity.” Listed as a contributing structure, 705 West Lynn is a Center-passage, Side Gable Classical Revival style, and individually eligible for National Register listing. Please consider our position in your decision process …

Scraped at: Feb. 5, 2025, 5:20 a.m.
Historic Landmark CommissionFeb. 5, 2025

10.3 - 2600 E Martin Luther King Jr Blvd - Updated Presentation 2-4 original pdf

Thumbnail of the first page of the PDF
Page 1 of 18 pages

2600 E Martin Luther King Jr Boulevard Historic Landmark Commission 2/5/2025 1 Project Site 2 Holy Cross Hospital 3 Existing Structure Existing Structure Landmark Designation Criteria LDC 25-2-352: 1. The property must be 50 years old and must represent a period of significance of at least 50 years ago; and 2. The property must retain a high degree of integrity, as defined by the National Register of Historic Places, that clearly conveys its historical significance and does not include an addition or alteration which has significantly compromised its integrity. Landmark Designation Criteria The property must meet at least two of the below criteria: i. Architecture ii. Historical Associations iii. Archaeology iv. Community Value v. Landscape Feature i. Architecture ARCHITECURE CRITERIA: √ Embodies the distinguishing characteristics of a recognized Staff Report: architectural style, type, or method of construction; × Exemplifies technological innovation in design or construction; × Displays high artistic value in representing ethnic or folk art, architecture, or construction; × Represents a rare example of an architectural style in the city; × Serves as an outstanding example of the work of an architect, builder, or artisan who significantly contributed to the development of the city, state, or nation; × Possesses cultural, historical, or architectural value as a particularly fine or unique example of a utilitarian or vernacular structure; or × Represents an architectural curiosity or one-of-a-kind building. “Mid-century Modern design by Page, Southerland and Page, however, its context as part of a larger hospital campus is gone” ii. Historical Associations HISTORICAL CRITERIA: The property has long-standing significant associations with persons, groups, institutions, businesses, or events of historic importance which contributed significantly to the history of the city, state, or nation; or represents a significant portrayal of the cultural practices or the way of life of a definable group of people in a historic time. • Holy Cross Hospital (established in 1940) was the first hospital to allow Black doctors in Austin • The site received a Texas Historical Commission marker in 2021, however the main hospital has been demolished. • Original Holy Cross Hospital site on 12th St has marker. ii. Historical Marker – 1610 E 11th St. iv. Community Value COMMUNITY CRITERIA: The property has a unique location, physical characteristic, or significant feature that contributes to the character, image, or cultural identity of the city, a neighborhood, or a particular group. • Holy Cross Hospital history is the basis …

Scraped at: Feb. 5, 2025, 5:20 a.m.
Historic Landmark CommissionFeb. 5, 2025

11.3 - 8401 Hathaway Dr - Burnet Middle School - Design Narrative original pdf

Thumbnail of the first page of the PDF
Page 1 of 2 pages

SUMMARY OF SCOPE As part of the 2022 Bond, Burnet Middle School will receive a full modernization of the existing campus at its current location. The modernization of Burnet Middle School will involve a full campus replacement on its current site at 8401 Hathaway Drive, Austin, TX 78757. The new campus will include a building that features flexible learning spaces to support a variety of learning styles, updated spaces for CTE, Fine Arts, and Athletics, spaces for mental health and wellness, and spaces to support the community. The design of the site will feature updated parking, site circulation, outdoor learning spaces, and outdoor athletics spaces. The design of Burnet Middle School will be created with the community it serves, via the Austin ISD Campus Architectural Team (CAT) process, wherein design decisions will be made collaboratively with educators, campus leaders, parents, and community members serving on the CAT. The future Burnet Middle School will be a medium-sized middle school, designed for an 1100-1300 student capacity at a programmed size of 248,000 GSF. DESIGN OVERVIEW The Burnet Middle School project is a transformational project that re-develops an existing 160,000 sf building with a state-of-the-art modern educational program of 248,000 sf. The new facility will be constructed on top of the existing playfields, allowing the existing building to remain operational while the new facility is being constructed. The project includes the complete redevelopment of the project site, including hardscape/landscape for students, outdoor learning environments, athletic facilities, and vehicular access for student drop-off, emergency vehicles, and service, as well as parking for visitors, staff, and operations team. The site preserves existing trees, re-imaging the area of the existing building into a student park for both informal and formal outdoor activities. The existing Burnet Middle School was designed and constructed in the late 1950’s, opening for the 1960- 61 school year. The building is a classic modern school design with expressed steel structure, daylit classrooms designed with natural ventilation, wide corridors and natural ceilings. The exposed roof deck is made with wood fiber, doubling with acoustical purposes to dampen sound in the building. Natural materials throughout have been a hard-working solution to serve the building for over 60 years, brick walls in public spaces and wood panels in classroom corridors bring durability and warmth, interior windows and clerestories provide daylight and views throughout the school. Wayfinding is natural and intuitive in the building. There are …

Scraped at: Feb. 5, 2025, 5:20 a.m.
Historic Landmark CommissionFeb. 5, 2025

11.4 - 8401 Hathaway Dr - Burnet Middle School - ESA Report original pdf

Thumbnail of the first page of the PDF
Page 1 of 9 pages

Educational Suitability Summary Report Burnet Middle School Date: 10/22/2020 Score 51% Average Burnet Middle School, serving a student enrollment of approximately 950 students in north central Austin, has a focus on dual language, STEAM, and agricultural studies. A large, covered walkway around four mature elm trees at the front of the building creates a welcoming and distinct entry. The building configuration with three parallel studio wings connected by a main hallway gives ample daylight in the learning spaces. In the learning spaces, the lighting and temperature controls do not meet modern standards. The original windows from 1961 are single pane and inefficient. Blinds to control daylight are generally in disrepair, and many of the mini blinds do not function. Acoustic separation between studios and the hallway is undermined by large return air grilles. Acoustics are also reported to be inadequate in the administration space. The campus amenities are numerous and in good condition. The spacious Learning Garden is well equipped and well maintained, providing an excellent space for environmental education. An Austin Energy pavilion provides space for an outdoor studio and is equipped with solar panels near the front of the school. However, many of the original features are not functional. In addition, three secure courtyards have the potential to be ideal spaces for outdoor learning. Sports fields and a full running track are in good condition and well secured by a perimeter fence. There are two tennis courts as well but are in poor condition. Interview Overview The interview took place virtually with Principal De la Rosa, Admin Secretary Izela Thomas, and District Project Managers Jorge Ledesma and James Belle. The interview highlighted many of the shortcomings with the current building. Burnet Middle School sits on a large site, and the school could have outdoor learning spaces, but upgrades are needed. They use the field for SEL classes for the 6th grade, but Wi-Fi coverage is spotty past a certain area outside the building. The Austin Energy pavilion is used as an outdoor studio, but additional outdoor learning spaces could be created with increased furniture and covered areas. The school has a few items that should never change. The campus has heritage trees, two stone memorials in the courtyard dedicated to students, an anchor at the front of the school, a plaque to commemorate the school’s history, and a teacher memorial. There are programs not in suitable space. Dance …

Scraped at: Feb. 5, 2025, 5:20 a.m.
Historic Landmark CommissionFeb. 5, 2025

11.5 - 8401 Hathaway Dr - Burnet Middle School - ESA original pdf

Thumbnail of the first page of the PDF
Page 1 of 1 page

Burnet Middle School Educational Suitability Assessment, October 2020 Building Address: 8401 Hathaway Dr. Austin, TX 78757 Building Area: 149,000 Square Feet Site: 23 Acres Date of First Construction: 1961 Assessment Timeline: ESA Interview: Not Completed ESA Field Visit: 10/22/20 ESA Score 51% District MS ESA Average: TBD Very Unsatisfactory 0-35 Unsatisfactory 36-50 Average 51-65 Satisfactory 66-80 Very Satisfactory 81-100 Questions/Comments? Email: Assessments@perkinswill.com AISD Assessment Survey: https://www.surveymonkey. com/r/aisdassessments 67% 47% 54% 44% 36% 60% 40% 51% 53% 40% 60% What is an ESA? The ESA measures the degree to which the facility supports teaching and learning. It considers the exterior, general building, security, environmental quality, controllability of lighting systems, furniture, equipment, academic spaces, support spaces, technology, and administration spaces. *This score is not a representation of the school’s academic performance and does not reflect any construction or improvements performed after the assessment date. General 1 - Exterior 2 - General Building 3 - Security 4 - Environmental Quality 5 - Controllability of Systems 6 - Furniture, Fixtures, Equipment 7 - Zero Waste Academics 1 - Academic & Co-Curricular Support 2 - Media Resources 3 - Technology 4 - Administration Spaces

Scraped at: Feb. 5, 2025, 5:20 a.m.
Historic Landmark CommissionFeb. 5, 2025

11.6 - 8401 Hathaway Dr - Burnet Middle School - Historical Components original pdf

Thumbnail of the first page of the PDF
Page 1 of 3 pages

Narrative of Historical Components 1. Wood Gymnasium Floor The existing wood gymnasium floor has a sailor mascot graphic at center court. The intent is to transfer a portion of the wood floor and this graphic to the gymnasium in the new building. 2. Entry Pavilion There is an entry pavilion at the existing school. This pavilion will be preserved as a free-standing structure that will offer shade along the walking path of the new school. 3. Covered Walkways The existing building utilizes metal covered walkways to connect exterior portions of the building. The new building will use the same style of covered walkway as a reference to the historical design of the original building.

Scraped at: Feb. 5, 2025, 5:20 a.m.
Historic Landmark CommissionFeb. 5, 2025

11.7 - 8401 Hathaway Dr - Burnet Middle School - Project Schedule original pdf

Thumbnail of the first page of the PDF
Page 1 of 1 page

Burnet MS -Project Schedule Overview 5 2 0 2 6 2 0 2 7 2 0 2 8 2 0 2 NEW BUILDING CONSTRUCTION Permit Spring 2025 Construction Start Q3 2025 Start Move-In Q2 2027 School Opening August 2027 DESIGN DD Aug 2024 CD Mar 2025 EXISTING BUILDING DEMO & SITEWORK (Proposed dates are subject to change) Demo Summer 2027 Site work Complete Q2 2028 1

Scraped at: Feb. 5, 2025, 5:20 a.m.
Historic Landmark CommissionFeb. 5, 2025

11.8 - 8401 Hathaway Dr - Burnet Middle School - Additions and Modifications Narrative original pdf

Thumbnail of the first page of the PDF
Page 1 of 2 pages

Narrative of Additions and Modifications 1. The first wing of the building was damaged by vehicle impact in 2022. This has resulted in structural and envelope damage that left 4 classrooms condemned. 2. Unscreened rooftop mechanical units and ducting have been added to the roof across the building. 3. There are numerous portable air conditioning units in the athletic and fine arts wing that have cut openings into existing walls and window systems without altering the surrounding materials in a historic manner.

Scraped at: Feb. 5, 2025, 5:20 a.m.
Historic Landmark CommissionFeb. 5, 2025

07.2 - 705 West Lynn St - Site Plan original pdf

Thumbnail of the first page of the PDF
Page 1 of 1 page

T E E R T S N N Y L T S E W 580 SF 695 SF 450 SF 450 SF 1345 SF FRONT UNIT AREA EXISTING ADDITION GARAGE SECOND FLOOR CONDITIONED AREA SQ. FT. 580 SF. 695 SF. 450 SF. 1,145 SF. 2,420 SF. REAR UNIT AREA FIRST FLOOR FRONT PORCH REAR PORCH SECOND FLOOR GARAGE SQ. FT. 1,345 SF. 64 SF. 142 SF. 1,551 SF. 450 SF. CONDITIONED AREA 2,896 SF.

Scraped at: Feb. 5, 2025, 7:50 p.m.
Historic Landmark CommissionFeb. 5, 2025

10.4 - 2600 E Martin Luther King Jr Blvd - Postponement Request original pdf

Thumbnail of the first page of the PDF
Page 1 of 3 pages

From: To: Cc: Subject: Date: Attachments: Contreras, Kalan Harden, Joi; Fahnestock, Sam McKnight, Kim RE: 2600 E MLK - Postponement Request Wednesday, February 5, 2025 1:40:13 PM image001.png Thank you for sending, Leah. Sam, could you please post this request to backup for this evening? Thanks! Kalan Contreras Historic Preservation Officer Planning Department 512-974-2727 kalan.contreras@austintexas.gov From: Leah Bojo < Sent: Wednesday, February 5, 2025 1:36 PM To: Contreras, Kalan <Kalan.Contreras@austintexas.gov>; Harden, Joi <Joi.Harden@austintexas.gov> Subject: FW: 2600 E MLK - Postponement Request > External Email - Exercise Caution FYI Leah M. Bojo, AICP, Director of Land Use & Entitlements 2705 Bee Caves Road, Suite 100, Austin, TX 78746 Drenner Group, PC | 512-665-1570 cell | | www.drennergroup.com > From: Misael Ramos < Date: Tuesday, February 4, 2025 at 12:30 PM To: BC-Trey.McWhorter@austintexas.gov <BC-Trey.McWhorter@austintexas.gov>, BC- Raymond.Castillo@austintexas.gov <BC-Raymond.Castillo@austintexas.gov>, bc- jamie.alvarez@austintexas.gov <bc-jamie.alvarez@austintexas.gov>, BC- Carl.Larosche@austintexas.gov <BC-Carl.Larosche@austintexas.gov>, bc- roxanne.evans@austintexas.gov <bc-roxanne.evans@austintexas.gov>, BC- Harmony.Grogan@austintexas.gov <BC-Harmony.Grogan@austintexas.gov>, BC- Ben.Heimsath@austintexas.gov <BC-Ben.Heimsath@austintexas.gov>, Koch, Kevin - >, Temaria Davis BC <BC-Kevin.Koch@austintexas.gov> Cc: Leah Bojo < < Marshall < Bertron, Cara <Cara.Bertron@austintexas.gov>, Pat Calhoun < Walker < Subject: 2600 E MLK - Postponement Request >, Brenda Malik < , Marilyn < >, BERRI MCBRIDE < Christopher Page < > >, Lavon >, Jen Margulies >, >, Jim Good Afternoon Historic Landmark Commissioners, We’re sending this email to keep all of you in the loop during our conversations with Drenner Group. Drenner Group met with our neighborhood on Monday, February 3rd at 1:30 pm. Our neighborhood sent over a list of pre-demolition items before the meeting that would have addressed concerns for preserving our historic district from potential hazards due to the demolition of the current structure and development of the newly proposed one. Drenner Group told us most items could not be addressed by them but all parties did agree to working on a restrictive covenant that would support our neighborhood. Drenner group also agreed to send a list of items for us to review and our neighborhood kindly requests to receive these items no later than 4 pm today so that we have time to discuss them. Given the compressed timeline, our neighborhood would like to request a postponement of the demolition permit application to allow for further discussions and negotiation of the restrictive covenant details with the Drenner Group. Our neighborhood is not against the development of this property but we are concerned about possible contamination (radiation, groundwater pollution), flooding, and an …

Scraped at: Feb. 5, 2025, 7:50 p.m.
Historic Landmark CommissionFeb. 5, 2025

Play video original link

Play video

Scraped at: Feb. 7, 2025, 12:50 a.m.
Historic Landmark CommissionFeb. 5, 2025

06.a - 1908 Kenwood Ave - public comment original pdf

Thumbnail of the first page of the PDF
Page 1 of 1 page

Backup

Scraped at: March 25, 2025, 9:48 p.m.
Historic Landmark CommissionFeb. 5, 2025

07.b - 705 West Lynn St - public comment original pdf

Thumbnail of the first page of the PDF
Page 1 of 1 page

Backup

Scraped at: March 25, 2025, 9:48 p.m.
Historic Landmark CommissionFeb. 5, 2025

07.c - 705 West Lynn St - public comment original pdf

Thumbnail of the first page of the PDF
Page 1 of 1 page

Backup

Scraped at: March 25, 2025, 9:48 p.m.
Historic Landmark CommissionFeb. 5, 2025

Approved Minutes original pdf

Thumbnail of the first page of the PDF
Page 1 of 7 pages

HISTORIC LANDMARK COMMISSION WEDNESDAY, February 5th, 2025 – 6:00 PM City Hall – Council Chambers 301 W. 2nd Street Austin, TX 78701 Some members of the Commission may be participating by videoconference. The meeting may be viewed online at: http://www.austintexas.gov/page/watch-atxn-live. Public comment will be allowed in-person or remotely via telephone. Speakers may only register to speak on an item once either in-person or remotely and will be allowed up to three minutes to provide their comments. Registration no later than noon the day before the meeting is required for remote participation by telephone. To register to speak remotely, email preservation@austintexas.gov or call Sam Fahnestock at (512) 974-3393. COMMISSION MEMBERS: Ben Heimsath, Chair x Roxanne Evans, Vice Chair x Kevin Koch x Carl Larosche x x x x ab Trey McWhorter Harmony Grogan Jaime Alvarez Raymond Castillo APPROVED MINUTES CALL TO ORDER PUBLIC COMMUNICATION: GENERAL The first (10) speakers who register to speak no later than noon the day before the meeting will be allowed a three-minute allotment to address their concerns regarding items not posted on the agenda. APPROVAL OF MINUTES 1. January 8, 2025 – Offered for consent approval. BRIEFINGS 1 HISTORIC LANDMARK COMMISSION MEETING MINUTES (March 5, 2025) 2. Briefing on the FY25 Recommended Heritage Preservation Grants Presenter: Melissa Alvarado CONSENT/CONSENT POSTPONEMENT AGENDA Historic Landmark and Local Historic District Applications 3. HR-2024-095142 – 2504 Bridle Path Culberson House Council District 10 Proposal: Addition, new doors and windows, new cabana, new siding. (Postponed January 8, 2025) Applicant: Minnie Webb City Staff: Austin Lukes, Historic Preservation Office, 512-978-0766 Staff Recommendation: Grant the applicant’s request to postpone the public hearing to March 5, 2025. MOTION: Postpone the public hearing to March 5, 2025, per passage of the consent postponement agenda, on a motion by Commissioner Koch. Commissioner Larosche seconded the motion. Vote: 7-0. The motion passed. National Register District Permit Applications 4. HR-2024-123060 – 1003 Maufrais St. West Line National Register Historic District Council District 9 Proposal: Addition and remodel, new construction of a cabana and pool. (Postponed January 8, 2025) Applicant: Jennifer Hanlen City Staff: Kalan Contreras, Historic Preservation Office, 512-974-2727 Staff Recommendation: Grant the applicant’s request to postpone the public hearing to March 5, 2025. MOTION: Postpone the public hearing to March 5, 2025, per passage of the consent postponement agenda, on a motion by Commissioner Koch. Commissioner Larosche seconded the motion. Vote: 7-0. The motion passed. Item 5 …

Scraped at: April 9, 2025, 6:41 p.m.
Environmental CommissionFeb. 5, 2025

Agenda original pdf

Thumbnail of the first page of the PDF
Page 1 of 3 pages

Regular Meeting of the Environmental Commission February 5, 2025 at 6:00 PM Permitting And Development Center, Events Center, Room 1405 6310 Wilhelmina Delco Drive Austin, Texas 78752 Some members of the Environmental Commission will be participating by videoconference. The meeting may be viewed online at: http://www.austintexas.gov/page/watch-atxn-live Public comment will be allowed in-person or remotely via telephone. Speakers may only register to speak on an item once either in-person or remotely and will be allowed up to three minutes to provide their comments. Registration no later than noon the day before the meeting is required for remote participation by telephone. To register to speak remotely, call or email Elizabeth Funk, Watershed Protection Department, at (512) 568-2244, Elizabeth.Funk@austintexas.gov, no later than noon the day before the meeting. The following information is required: speaker name, item number(s) they wish to speak on, whether they are for/against/neutral, email address and telephone number (must be the same number that will be used to call into the meeting). CURRENT COMMISSIONERS: Haris Qureshi Mariana Krueger Melinda Schiera Hanna Cofer, Vice Chair Colin Nickells Jennifer Bristol, Secretary David Sullivan Richard Brimer Perry Bedford, Chair CALL TO ORDER PUBLIC COMMUNICATION: GENERAL AGENDA The first 10 speakers signed up prior to the meeting being called to order will each be allowed a three-minute allotment to address their concerns regarding items not posted on the agenda. APPROVAL OF MINUTES Approve the minutes of the Environmental Commission Regular Meeting on December 4, 2024 1 1. DISCUSSION ITEMS Presentation and discussion on Austin Light Rail Update – Austin Transit Partnership staff. PUBLIC HEARINGS AND ACTION ITEMS Name: Westcreek Mixed Use, SP-2023-0276C Applicant: Quiddity, Justin Cadieux, PE Location: 5725 W US 290 Highway EB, Austin, TX, 78749 Council District: District 8 Staff: Mike McDougal, Environmental Policy Program Manager, Development Services Department; 512-974-6380, mike.mcdougal@austintexas.gov Applicant request: Redevelopment Exception in the Barton Springs Zone [LDC 25-8- 26] Staff Recommendation: Staff recommends the Redevelopment Exception for this project. Name: Taylor Slough Dredge Maintenance, SP-2024-0019D Applicant: Janis J. Smith, P.E., Janis Smith Consulting Location: 3704 ½ Meadowbank Dr, Austin, TX, 78703 Council District: District 10 Staff: Miranda Reinhard, Environmental Scientist Senior, Watershed Protection Department 512-978-1537, miranda.reinhard@austintexas.gov Applicant request: Request to vary from LDC 25-8-261(C)(9)(a) to allow more than 25 cubic yards of dredging in Lake Austin. Staff Recommendation: Staff recommends this variance with conditions DISCUSSION AND ACTION ITEMS Presentation, discussion, and action regarding a recommendation to Austin City …

Scraped at: Jan. 31, 2025, 10:40 a.m.
Environmental CommissionFeb. 5, 2025

20250205-001: Draft Minutes Dec 4, 2024 EVC meeting original pdf

Thumbnail of the first page of the PDF
Page 1 of 3 pages

1. 2. ENVIRONMENTAL COMMISSION REGULAR CALLED MEETING MINUTES Wednesday, December 4, 2024 The Environmental Commission convened in a Regular meeting on Wednesday, December 4, 2024, at 6310 Wilhelmina Delco Drive in Austin, Texas. Chair Bedford called the Environmental Commission Meeting to order at 6:02 p.m. Commissioners in Attendance: Perry Bedford, Jennifer Bristol, Hanna Cofer, Mariana Krueger, Haris Qureshi, Melinda Schiera, David Sullivan, Commissioners in Attendance Remotely: Commissioners Absent: Colin Nickells and Richard Brimer PUBLIC COMMUNICATION: GENERAL None APPROVAL OF MINUTES Approve the minutes of the Environmental Commission Regular Meeting on November 6, 2024 The minutes of the Environmental Commission Regular Meeting on November 6, 2024 were approved on Commissioner Bristol’s motion, Commissioner Cofer’s second on a 7-0 vote. Commissioners Nickells and Brimer were absent. PUBLIC HEARINGS AND ACTION ITEMS Name: Dredge of Channel Rd. Lagoon, SP-2023-0367D Applicant: Stephen Hawkins, Aqua Permits Location: 4824 Laguna Ln, Austin, TX, 78746 Council District: District 8 Staff: Miranda Reinhard, Environmental Scientist Senior, Watershed Protection Department; 512-978-1537, miranda.reinhard@austintexas.gov Applicant request: Request to vary from LDC 25-8-261(C)(9)(a) to allow more than 25 cubic yards of dredging in Lake Austin. Staff Recommendation: Recommended with conditions Speakers: Miranda Reinhard, WPD 1 3. 4. 5. Jon Fichter, Aqua Permits Liz Johnston, Interim Environmental Officer A motion to close the public hearing passed on Commissioner Bedford’s motion, Commissioner Krueger’s second, on a 7-0 vote. Commissioners Nickells and Brimer were absent. A motion to recommend the Dredge of Channel Rd. Lagoon variance request with conditions passed on Commissioner Bristol’s motion, Commissioner Bedford’s second, on a 7–0 vote. Commissioners Nickells and Brimer were absent. Name: Loyola Flats, SP-2024-0147C.SH Applicant: Allison Lehman, Kimley-Horn Location: 6700 Decker Lane, Austin, TX, 78724 Council District: District 1 Staff: Miranda Reinhard, Environmental Scientist Senior, Watershed Protection Department; 512-978-1537, miranda.reinhard@austintexas.gov Applicant request: Request to vary from LDC 25-8-261(G) to allow floodplain modification in the Critical Water Quality Zone (CWQZ) Staff Recommendation: Recommended with conditions Speakers: Miranda Reinhard, WPD Dwayne Shoppa, Kimey-Horn A motion to close the public hearing passed on Commissioner Bedford’s motion, Commissioner Krueger’s second, on a 7-0 vote. Commissioners Nickells and Brimer were absent. A motion to recommend the Loyola Flats variance request with conditions passed on Commissioner Bristol’s motion, Commissioner Bedford’s second, on a 7–0 vote. Commissioners Nickells and Brimer were absent. DISCUSSION AND ACTION ITEMS Discussion and recommendation on strategies to improve the tree canopy in Austin – Environmental Commissioners Richard Brimer and Melinda …

Scraped at: Jan. 31, 2025, 10:40 a.m.
Environmental CommissionFeb. 5, 2025

20250205-002: Austin Light Rail Progress Update original pdf

Thumbnail of the first page of the PDF
Page 1 of 2 pages

Provide Feedback and Stay Involved Meeting Dates and Locations JAN 16 JAN 25 Lively Middle School Montopolis Rec Center 201 E Mary St. 1200 Montopolis Dr. JAN 22 Baker Center 3908 Avenue B JAN 28 UT Quadrangle Room 2308 Whitis Ave. Proposed Light Rail Timeline A public review and comment period for the DEIS will be conducted from January 10 through March 11, 2025. Comments received during this period will be addressed in the Final Environmental Impact Statement. View the online public meeting information. Austin Light Rail PROGRESS UPDATE January 2025 Bridge Over Lady Bird Lake View from inside the train, crossing Lady Bird Lake. Artist conceptual visualization Austin Light Rail Phase 1 is underway. This momentous transportation investment will offer an all-new transit experience, running reliably every 5 to 10 minutes to connect people to major job centers, education hubs, and iconic Austin destinations. Key progress highlights Continuing the design Recommendations to: • Add a new downtown station near Wooldridge Square. • Extend the bridge over Lady Bird Lake and elevate the Waterfront Station. • Refine station locations on East Riverside. • Advance a Greenway concept along East Riverside, featuring a continuous bike/pedestrian corridor and creating tree canopy and shade. Hitting major milestones in the federal funding process Including: Release of the Draft Environmental Impact Statement (DEIS). The DEIS is a critical step towards federal grant funding. Developing the contracting and delivery approach Including: Onboarding the Delivery Partner. Artist conceptual visualization Artist conceptual visualization East Riverside A new shaded walk and bike path along the line on East Riverside, designed to improve walkability. Benefits of Light Rail New Options to Get Places Easy, Reliable & Frequent Reduced Travel Times The line will integrate with cars, Light rail will have its own dedicated The line will allow riders to zip buses, trains and other modes — railway, intuitive directions, and run through the heart of Austin without giving people more choices when every 5-10 minutes — making it having to sit in traffic — significantly navigating between the core and the highly dependable and easy to use. reducing travel times to key larger metro area. Nature-forward Design An Engine for Jobs destinations. Keeps Austin Livable Shade trees, Texas plants, and new Light rail will create 10,000 jobs The line will help keep our city walk and bike paths will be integrated as a key part of city mobility accessible for …

Scraped at: Jan. 31, 2025, 10:40 a.m.