All documents

RSS feed for this page

LGBTQ Quality of Life Advisory CommissionMay 10, 2021

Agenda original pdf

Thumbnail of the first page of the PDF
Page 1 of 4 pages

Versión en español a continuación. LGBTQ Quality of Life Advisory Commission Meeting May 10, 2021 LGBTQ Quality of Life Advisory Commission to be held May 10, 2021, with Social Distancing Modifications Public comment will be allowed via telephone; no in-person input will be allowed. All speakers must register in advance (May 9, 2021 by noon). All public comment will occur at the beginning of the meeting. To speak remotely at the May 10, 2021, LGBTQ Quality of Life Advisory Commission Meeting, members of the public must: •Call or email the board liaison at (512) 974-2154 or neal.falgoust@austintexas.gov no later than noon April 11, 2021. The following information is required: speaker name, item number(s) they wish to speak on, whether they are for/against/neutral, email address and telephone number (must be the same number that will be used to call into the meeting). •Once a request to speak has been made to the board liaison, the information to call on the day of the scheduled meeting will be provided either by email or phone call. •Speakers must call in at least 15 minutes prior to meeting start time in order to speak, late callers will not be accepted and will not be able to speak. •Speakers will be placed in a queue until their time to speak. •Handouts or other information may be emailed to neal.falgoust@austintexas.gov by noon the day before the scheduled meeting. This information will be provided to Board and Commission members in advance of the meeting. •If the meeting is broadcast live, it may be viewed here: http://www.austintexas.gov/page/watch-atxn-live Reunión del LGBTQ Quality of Life Advisory Commission la May 10, 2021 La junta se llevará con modificaciones de distanciamiento social. Se permitirán comentarios públicos por teléfono; no se permitirá ninguna entrada en persona. Todos los oradores deben registrarse con anticipación (May 9, 2021, antes del mediodía). Todos los comentarios públicos se producirán al comienzo de la reunión. Para hablar de forma remota en la reunión, los miembros del público deben: • Llame o envíe un correo electrónico al enlace de junta en (512) 974-2154, neal.falgoust@austintexas.gov a más tardar al mediodía (el día antes de la reunión). Se requiere la siguiente información: nombre del orador, número (s) de artículo sobre el que desean hablar, si están a favor / en contra / neutral, dirección de correo electrónico (opcional) y un número de teléfono (debe ser el número que se utilizará para …

Scraped at: May 5, 2021, 4:20 p.m.
HIV Planning CouncilMay 10, 2021

Agenda original pdf

Thumbnail of the first page of the PDF
Page 1 of 4 pages

Versión en español a continuación. The Strategic Planning/Needs Assessment Committee Meeting of the HIV Planning Council MONDAY, May10, 2021 The Strategic Planning/Needs Assessment Committee Meeting to be held May 10, 2021 with Social Distancing Modifications Public comment will be allowed via telephone; no in-person input will be allowed. All speakers must register in advance (05/9/2021 by noon). All public comment will occur at the beginning of the meeting. To speak remotely at the May 10, 2021 HIV Planning Council Meeting, members of the public must: •Call or email the board liaison at (512) 972-5806 and Jaseudia.Killion@austintexas.gov no later than noon, (the day before the meeting). The information required is the speaker name, item number(s) they wish to speak on, whether they are for/against/neutral, and a telephone number or email address. •Once a request to speak has been called in or emailed to the board liaison, residents will receive either an email or phone call providing the telephone number to call on the day of the scheduled meeting. •Speakers must call in at least 15 minutes prior to meeting start in order to speak, late callers will not be accepted and will not be able to speak. •Speakers will be placed in a queue until their time to speak. •Handouts or other information may be emailed to Jaseudia.Killion@austintexas.gov by Noon the day before the scheduled meeting. This information will be provided to Board and Commission members in advance of the meeting. •If this meeting is broadcast live, residents may watch the meeting here: http://www.austintexas.gov/page/watch- atxn-live la junta en Reunión del Strategic Planning/Needs Assessment Committee Meeting of the HIV Planning Council MONDAY, May 10, 2021 FECHA de la reunion (Mayo 10, 2021) La junta se llevará con modificaciones de distanciamiento social Se permitirán comentarios públicos por teléfono; no se permitirá ninguna entrada en persona. Todos los oradores deben registrarse con anticipación (05/9/2021 antes del mediodía). Todos los comentarios públicos se producirán al comienzo de la reunión. Para hablar de forma remota en la reunión, los miembros del público deben: • Llame o envíe un correo electrónico al enlace de (512) 972-5806 and Jaseudia.Killion@austintexas.gov a más tardar al mediodía (el día antes de la reunión). La información requerida es el nombre del orador, los números de artículo sobre los que desean hablar, si están a favor / en contra / neutrales, y un número de teléfono o dirección de correo electrónico. • Una …

Scraped at: May 8, 2021, 1:40 a.m.
Historic Landmark CommissionMay 10, 2021

Agenda original pdf

Thumbnail of the first page of the PDF
Page 1 of 4 pages

Versión en español a continuación. Historic Landmark Commission Special Meeting of the Architectural Review Committee Monday, May 10, 2021, 2:00 PM ARCHITECTURAL REVIEW COMMITTEE MEETING TO BE HELD MONDAY, MAY 10, 2021 WITH SOCIAL DISTANCING MODIFICATIONS This meeting is limited in duration. Please make presentations as brief as possible (consider 5 minutes) so that all applicants may have the chance to present to and receive input from the committee members. This is a virtual meeting; no in-person input will be allowed. Community members may register for citizen communication but may not speak on specific cases on the agenda. The opportunity for public input on specific cases will occur at a subsequent meeting of the Historic Landmark Commission. This meeting is not televised. Community members may also register to receive call in information and listen to the meeting via telephone. All participants must register in advance (no later than 12:00 noon on Sunday, May 9, 2021 to be notified of the call-in number and other instructions). To listen to or participate in the Architectural Review Committee meeting, all persons must: • Call or email the board liaison at (512) 974-3393 or preservation@austintexas.gov no later than noon, Sunday, May 9, 2021 (the day before the meeting). The following information is required: speaker name, item number(s) they wish to speak on, whether they are for/against/neutral, email address and telephone number (must be the same number that will be used to call into the meeting). • Once a request to speak has been made to the board liaison, the information to call on the day of the scheduled meeting will be provided either by email or phone call. • Speakers must call in at least 15 minutes prior to meeting start time in order to speak, late callers will not be accepted and will not be able to speak. • Speakers will be placed in a queue until their time to speak. • Handouts or other information may be emailed to preservation@austintexas.gov by noon the day before the scheduled meeting. This information will be provided to Board and Commission members in advance of the meeting. Reunión especial del Historic Landmark Commission, Architectural Review Committee FECHA de la reunion 10 de mayo 2021 a las dos de la tarde (2:00 p.m.) LA JUNTA SE LLEVARÁ EL LUNES, EL 10 DE MAYO 2021 CON MODIFICACIONES DE DISTANCIAMIENTO SOCIAL Esta reunion tiene una duracion limitada. Haga todas …

Scraped at: May 7, 2021, 4:20 p.m.
Historic Landmark CommissionMay 10, 2021

1 - 612 Highland Ave original pdf

Thumbnail of the first page of the PDF
Page 1 of None page

Backup

Scraped at: May 7, 2021, 4:20 p.m.
Historic Landmark CommissionMay 10, 2021

6 - 905 E 2nd St original pdf

Thumbnail of the first page of the PDF
Page 1 of 10 pages

SARAH SMITH AND BRYAN THOMPSON 905 E 2ND STREET AUSTIN TX REMODEL WITH SQFT ADDITION SF3-NP SHEET INDEX General Drawings G-001 G-002 COVER SHEET NOTES Architectural Site Plans AS-001 AS-002 AS-003 SITE PLAN SURVEY TREE PLAN DEMOLITION PLAN FLOOR PLANS ELEVATIONS SECTIONS ROOF PLAN A - 101 FIRST FLOOR DEMOLITION... A-102 A-103 FIRST FLOOR PLAN SECOND FLOOR PLAN A-201 A-202 A-203 A-204 NORTHEAST ELEVATION SOUTHWEST ELEVATION NORTHWEST ELEVATION SOUTHEAST ELEVATION A-301 BUILDING SECTION A A-302 ROOF PLAN ELECTRICAL PLANS A-401 A-402 FIRST FLOOR SECOND FLOOR INTERIOR ELEVATIONS A-501 A-502 KITCHEN BATHROOMS WINDOW SCHEDULE A-601 WINDOW SCHEDULE www.ahsdesigngroup.com 512-577-3644 RB ARCHITECTS PLLC NOVEMBER 2020 T E E R T S D N 2 T S A E 5 0 9 2 0 7 8 7 X T - N I T S U A L E D O M E R N O I T I D D A H T I W COVER SHEET SCALE 1' = 1'-0", 1" = 20', 1:274.29 G-001 www.ahsdesigngroup.com 512-577-3644 RB ARCHITECTS PLLC NOVEMBER 2020 T E E R T S D N 2 T S A E 5 0 9 2 0 7 8 7 X T - N I T S U A L E D O M E R N O I T I D D A H T I W SURVEY SCALE 1:51 AS-002 EXISTING BEDROOM PORCH UP NEW STAIRCASE TO NEW SECOND FLOOR NEW LIVING AREA NEW PATIO EXISTING BEDROOM EXISTING LIVING ROOM EXISTING KITCHEN AREA NEW DINING AREA F WALL TO BE BUILT WALL TO BE DEMOLISHED EXISTING WALL TO REMAIN DEMOLITION PLAN SCALE: 3/16" = 1'-0" www.ahsdesigngroup.com 512-577-3644 RB ARCHITECTS PLLC NOVEMBER 2020 T E E R T S D N 2 T S A E 5 0 9 2 0 7 8 7 X T - N I T S U A L E D O M E R N O I T I D D A H T I W FIRST FLOOR DEMOLITION PLAN SCALE 3/16" = 1'-0" A - 101 2'-0" : 5 2 1 EXISTING ROOF 2'-0" 12:5 METAL ROOF 12:5 : 5 2 1 2'-0" " 0 - ' 2 12:5 " 0 - ' 2 ROOF PLAN SCALE: 3/16" = 1'-0" www.ahsdesigngroup.com 512-577-3644 RB ARCHITECTS PLLC NOVEMBER 2020 T E E R T S D N 2 T S A E 5 0 9 2 0 7 8 7 X T - …

Scraped at: May 7, 2021, 4:20 p.m.
Historic Landmark CommissionMay 10, 2021

7 - 605 Oakland Ave - existing original pdf

Thumbnail of the first page of the PDF
Page 1 of 5 pages

Backup

Scraped at: May 7, 2021, 4:20 p.m.
Historic Landmark CommissionMay 10, 2021

7 - 605 Oakland Ave - proposed original pdf

Thumbnail of the first page of the PDF
Page 1 of 7 pages

Backup

Scraped at: May 7, 2021, 4:20 p.m.
Historic Landmark CommissionMay 10, 2021

9 - Guadalupe Storm Drain Improvements original pdf

Thumbnail of the first page of the PDF
Page 1 of 8 pages

# # #* # #* # #* # #* #* # #* P C R ' ' 6 3 # #* #* # #* P C R ' ' 0 3 # #* # #* P C R ' ' 4 2 #* # # #* # #* T S E P U L A D A U G #* #* #* Central Park Pond Baker #* Center Detention #* # #* # #* 5' x 5' CBC 36'' RCP W 39TH ST E 39TH ST #* W 38TH HALF ST # #* 36'' RCP # #* 9' x # 4 #* .2' C B C !( # #* 7' x 5' CBC W 38TH ST #* # # #* # Y A W D E E P S E 38TH ST E 37TH ST F E U N E V A I T S H T F F R G I # #* #* W 35TH ST E 35TH ST D E U N E V A #* #* #* # # #* # #* !( !( !( !( C E U N E V A # #* # #* #* # # #* !( # #* # #* # #* #* # B E U N E V A # #* #* #* C B C ' 8 x ' 9 # #* #* #* # # #* #* !(!( # # #* 24'' RCP #* # 24'' RCP #* # # #* # # #* #* P # #* C R #* ' ' 0 3 N L E M O H W 35TH ST 24'' RCP # #* # #* # # W 34TH ST # !( !(!( !( !( !( !( !( # #* !( !( #* K R A P L L H P M E H I !( # #* C B C ' 5 . 5 x ' 9 #*#* ## # #* #* # C E D A R S T # P C R ' ' 4 2 #* # #* # #* C B C ' 8 x ' 0 1 # W 33RD ST W 3 2N D ST T S B M O C S P L I T S S M L E H E 33RD ST E 34TH ST T S S M O O R G E 32ND ST Legend #* # E 3 …

Scraped at: May 7, 2021, 4:20 p.m.
Historic Landmark CommissionMay 10, 2021

9 - Guadalupe Storm Drain Improvements - presentation original pdf

Thumbnail of the first page of the PDF
Page 1 of None page

Backup

Scraped at: May 7, 2021, 4:21 p.m.
Historic Landmark CommissionMay 10, 2021

2 - 1304 Bob Harrison - Massing original pdf

Thumbnail of the first page of the PDF
Page 1 of 7 pages

1304 Bob Harrison - 3D Massing Fox Fox Studio ---- May 7th, 2021 East Facade Street Facade Fox Fox Studio ---- May 7th, 2021 New Addition: Vertical Metal Siding Historic House: Existing Vertical Board and Batten West Facade Street/ West Facade Fox Fox Studio ---- May 7th, 2021 East Facade (new addition) North Facade (new addition) Fox Fox Studio ---- May 7th, 2021 Remove Skylight on front roof Rebuild porch to existing specs Existing Vertical Board and Batten View 1: Street Facade Windows replaced with period wood clad Removed glass door and sidelight Fox Fox Studio ---- May 7th, 2021 View 2: Fox Fox Studio ---- May 7th, 2021 View 3: Fox Fox Studio ---- May 7th, 2021

Scraped at: May 10, 2021, 4:50 p.m.
Historic Landmark CommissionMay 10, 2021

2 - 1304 Bob Harrison - Plans original pdf

Thumbnail of the first page of the PDF
Page 1 of 7 pages

Residential New Construction and Addition Permit Application Property Information Project Address: Legal Description: Zoning District: DevelopmentATX.com | Phone: 311 (or 512-974-2000 outside Austin) For submittal and fee information, see austintexas.gov/digitaldevelopment Download application before entering information. Tax Parcel ID: Lot Area (sq ft): Historic District (if applicable): Neighborhood Plan Area (if applicable): Required Reviews Is project participating in S.M.A.R.T. Housing? (If yes, attach signed certification letter from NHCD, and signed conditional approval letter from Austin Energy Green Building) Is this site within an Airport Overlay Zone? (If yes, approval through Aviation is required) Y Y N N Does project have a Green Building requirement? (If yes, attach signed conditional approval letter from Austin Energy Green Building) Y N Does this site have a septic system? Y N (If yes, submit a copy of approved septic permit. OSSF review required) Does the structure exceed 3,600 square feet total under roof? Is this property within 200 feet of a hazardous pipeline? Y Y N N (If yes, Fire review is required) (If yes, Fire review is required) Is this site located within an Erosion Hazard Zone? Is this property within 100 feet of the 100-year floodplain? Y N (If yes, EHZ review is required) Y N (Proximity to floodplain may require additional review time.) Are there trees 19” or greater in diameter on/adjacent to the property? If yes, how many?_____ ( Provide plans with a tree survey, tree review required.) Y N Was there a pre-development consultation for the Tree Review? Y N Proposed impacts to trees: (Check all that apply) Root zone Canopy Removal None/Uncertain Is this site in the Capital View Corridor? (If yes, a preliminary review through land use is needed to determine if full view corridor review is required.) Does this site currently have: water availability? wastewater availability? Y Y Y N N N Is this site within the Residential Design and Compatibility Standards Ordinance Boundary Area? (LDC 25-2 Subchapter F) Y N (If no, contact Austin Water Utility to apply for water/wastewater taps and/or service extension request.) (If yes, submit approved auxiliary and potable plumbing plans.) Does this site have or will it have an auxiliary water source? (Auxiliary water supplies are wells, rainwater harvesting, river water, lake water, reclaimed water, etc.) Does this site require a cut or fill in excess of four (4) feet? Y N Y N (If yes, contact the Development Assistance Center for …

Scraped at: May 10, 2021, 4:50 p.m.
Historic Landmark CommissionMay 10, 2021

3 - 1805 E. 3rd Street - Herrera House original pdf

Thumbnail of the first page of the PDF
Page 1 of 8 pages

Residential New Construction and Addition Permit Application DevelopmentATX.com | Phone: 311 (or 512-974-2000 outside Austin) For submittal and fee information, see austintexas.gov/digitaldevelopment Download application before entering information. Zoning District: SF-3-H-NP (for front portion of property only) Lot Area (sq ft): 6,358.00 Property Information Project Address: 1805 E 3rd St 78702 Legal Description: Lot 3 Blk 2 Cypher Subdivision Neighborhood Plan Area (if applicable): Required Reviews N Is project participating in S.M.A.R.T. Housing? (If yes, attach signed certification letter from NHCD, and signed conditional approval letter from Austin Energy Green Building) East Cesar Chavez ■ Y Tax Parcel ID: 191991 Historic District (if applicable): N/A Does project have a Green Building requirement? (If yes, attach signed conditional approval letter from Austin Energy Green Building) Y N ■ Is this site within an Airport Overlay Zone? (If yes, approval through Aviation is required) Y ■ N Does this site have a septic system? Y N (If yes, submit a copy of approved septic permit. OSSF review required) ■ Does the structure exceed 3,600 square feet total under roof? Is this property within 200 feet of a hazardous pipeline? Y Y ■ ■ N N (If yes, Fire review is required) (If yes, Fire review is required) Is this site located within an Erosion Hazard Zone? Y N (If yes, EHZ review is required) ■ Is this property within 100 feet of the 100-year floodplain? ■ Y N (Proximity to floodplain may require additional review time.) Are there trees 19” or greater in diameter on/adjacent to the property? If yes, how many?_____ ( Provide plans with a tree survey, tree review required.) Was there a pre-development consultation for the Tree Review? Y ■ N Is this site in the Capital View Corridor? N (If yes, a preliminary review through land use is needed to determine if full view corridor review is required.) Does this site currently have: water availability? wastewater availability? Y Y ■ ■ Y ■ Does this site have or will it have an auxiliary water source? (Auxiliary water supplies are wells, rainwater harvesting, river water, lake water, reclaimed water, etc.) Does this site require a cut or fill in excess of four (4) feet? Y Y N ■ ■ Y ■ N Proposed impacts to trees: (Check all that apply) Root zone Canopy Removal None/Uncertain Is this site within the Residential Design and Compatibility Standards Ordinance Boundary Area? (LDC 25-2 …

Scraped at: May 10, 2021, 4:50 p.m.
Historic Landmark CommissionMay 10, 2021

4 - 1113 E 9th - drawings original pdf

Thumbnail of the first page of the PDF
Page 1 of 5 pages

Backup

Scraped at: May 10, 2021, 4:51 p.m.
Historic Landmark CommissionMay 10, 2021

4 - 1113 E 9th - elevation original pdf

Thumbnail of the first page of the PDF
Page 1 of 1 page

Backup

Scraped at: May 10, 2021, 4:51 p.m.
Historic Landmark CommissionMay 10, 2021

4 - 1113 E. 9th Street - Jobe House original pdf

Thumbnail of the first page of the PDF
Page 1 of 5 pages

Residential New Construction and Addition Permit Application Property Information Project Address: Legal Description: Zoning District: DevelopmentATX.com | Phone: 311 (or 512-974-2000 outside Austin) For submittal and fee information, see austintexas.gov/digitaldevelopment Download application before entering information. Tax Parcel ID: Lot Area (sq ft): Historic District (if applicable): Neighborhood Plan Area (if applicable): Required Reviews Is project participating in S.M.A.R.T. Housing? (If yes, attach signed certification letter from NHCD, and signed conditional approval letter from Austin Energy Green Building) Is this site within an Airport Overlay Zone? (If yes, approval through Aviation is required) Y Y N N Does project have a Green Building requirement? (If yes, attach signed conditional approval letter from Austin Energy Green Building) Y N Does this site have a septic system? Y N (If yes, submit a copy of approved septic permit. OSSF review required) Does the structure exceed 3,600 square feet total under roof? Is this property within 200 feet of a hazardous pipeline? Y Y N N (If yes, Fire review is required) (If yes, Fire review is required) Is this site located within an Erosion Hazard Zone? Is this property within 100 feet of the 100-year floodplain? Y N (If yes, EHZ review is required) Y N (Proximity to floodplain may require additional review time.) Are there trees 19” or greater in diameter on/adjacent to the property? If yes, how many?_____ ( Provide plans with a tree survey, tree review required.) Y N Was there a pre-development consultation for the Tree Review? Y N Proposed impacts to trees: (Check all that apply) Root zone Canopy Removal None/Uncertain Is this site in the Capital View Corridor? (If yes, a preliminary review through land use is needed to determine if full view corridor review is required.) Does this site currently have: water availability? wastewater availability? Y Y Y N N N Is this site within the Residential Design and Compatibility Standards Ordinance Boundary Area? (LDC 25-2 Subchapter F) Y N (If no, contact Austin Water Utility to apply for water/wastewater taps and/or service extension request.) (If yes, submit approved auxiliary and potable plumbing plans.) Does this site have or will it have an auxiliary water source? (Auxiliary water supplies are wells, rainwater harvesting, river water, lake water, reclaimed water, etc.) Does this site require a cut or fill in excess of four (4) feet? Y N Y N (If yes, contact the Development Assistance Center for …

Scraped at: May 10, 2021, 4:52 p.m.
Historic Landmark CommissionMay 10, 2021

5 - 1501 Northwood Rd - Plans original pdf

Thumbnail of the first page of the PDF
Page 1 of 13 pages

N o r t h w o o d R e m o d e l A u s t i n , T e x a s T r a v i s C o u n t y VICINITY MAP ABBREVIATIONS AD ADJ AFF APPROX BLDG BOB CB CJ CL CAB CLG CLKG CLO CNTR COL CONC CONSTR CONT CRPT CTR CTSK D DF DO DS DEPT DET DIA DIM DN DR DTL DW DWG DWR EG EXG EJ ELEV EQ EQUIP EXP EXT FA FD FF FFE FOC FOF FOS FDN FIN FLR FRZ FT FTG FURR GB GC GA GALV GL GND GR GWB HB HC HM HDW HDWD HDWR HNDCP HORIZ HR HT ID IN INSUL INT JST JT KIT LIN LB LAB LAM LAV LKR LT LTWT MC MO MECH N MANUFACTURER MINIMUM MIRROR MISCELLANEOUS MOUNTED METAL MULLION NORTH NOT IN CONTRACT NOT TO SCALE NOMINAL OVEN ON CENTER OUTSIDE DIAMETER/DIMENSION OVEN & MICROWAVE OBSCURE OPENING PORCELAIN TILE PLATE PLASTIC LAMINATE PLYWOOD PLASTER PLYWOOD PRE-CAST QUARRY BLOCK RISER OR RADIUS ROOF DRAIN ROUGH OPENING REFRIGERATOR - FREEZER ROOF RAFTER RADIUS RECOMMENDATION REFERENCE OR REFRIGERATOR REINFORCED REQUIRED REVISION REGISTER ROOM SOUTH STONE TILE SOLID CORE SOAP DISPENSER STAINLESS STEEL SERVICE SINK SCHEDULE SECTION SHELF SHOWER SIMILAR SPECIFICATION STANDARD STEEL STORAGE STRUCTURAL SYMMETRICAL TONGUE AND GROOVE TREAD TOWEL BAR TOP OF CURB TOP OF TOP OF BEAM TOP OF CONCETE TOP OF DOOR TOP OF WALL TOP OF PAVEMENT TOILET PAPER DISPENSER TRUSS TELEVISION TOP OF WALL TELEPHONE TEMPERED TERRAZO THICK OR THICKNESS TYPICAL UNLESS NOTES OTHERWISE UNFINISHED URNINAL VERTICAL VESTIBULE VERIFY IN FIELD VERIFY WITH BUILDER VERIFY WITH BUILDING DESIGNER VERIFY WITH STRUCTURAL ENGINEER VERIFY WITH INTERIOR DESIGNER VERIFY WITH LANDSCAPE DESIGNER VERIFY WITH LIGHTING DESIGNER VERIFY WITH MECHANICAL ENGINEER VERIFY WITH OWNER WEST OR WIDTH WATER CLOSET WROUGHT IRON WATERPROOF WITH WITHOUT WD WAINSCOT WEIGHT AREA DRAIN ADJUSTABLE ABOVE FINISH FLOOR APPROXIMATE BUILDING BOTTOM OF BEAM CATCH BASIN CEILING JOIST CENTERLINE CABINET CEILING CAULKING CLOSET COUNTER COLUMN CONCRETE CONSTRUCTION CONTINUOUS CARPET CENTER OR COUNTER COUNTERSUNK DIAMETER DOUGLASS FIR DOOR OPENING DOWNSPOUT DEPARTMENT DETAIL DIAMETER DIMENSION DOWN DOOR DETAIL DISHWASHER DRAWING DRAWER EXISTING GRADE EXISTING EXPANSION ELEVATION EQUAL EQUIPMENT EXPOSED EXTERIOR FIRE ALARM FLOOR DRAIN FINISH FACE FINISH FLOOR ELEVATION FACE OF CONCRETE FACE OF FINISH FACE OF STUCCO FOUNDATION FINISH FLOOR FREEZER FOOT OR FEET FOOTING FURRING GRAB BAR GENERAL CONTRACTOR GAUGE GALVANIZED GLASS …

Scraped at: May 10, 2021, 4:52 p.m.
Historic Landmark CommissionMay 10, 2021

5 - 1501 Northwood Rd - Renderings original pdf

Thumbnail of the first page of the PDF
Page 1 of 4 pages

Backup

Scraped at: May 10, 2021, 4:53 p.m.
Historic Landmark CommissionMay 10, 2021

8 - 307 E. 2nd St - presentation original pdf

Thumbnail of the first page of the PDF
Page 1 of 9 pages

Mitchell had two young daughters, both of whom had been born in Texas: Vida Lucille, 11; and Juanita, L., 9. His 1942 World War II draft registration card shows that Leonard East as living at this address. aff ordable housing, training for empowerment and life skills, and a supportive community to achieve life goals. Intracorp has developed the images and programming association with the relocation in concert with the Jeremiah Program. History The Leonard and Vida East house is currently located at 307 E. 2nd Street in the Central Business District of downtown Austin. Research by the City of Austin Historic Preservation Offi ce House states that the house was likely relocated to this lot ca. 1928 from an unknown location. The 1935 Sanborn Map depicts structure as a wood frame house with no synthetic siding, while the 1961 Sanborn Map indicates that the house has asbestos siding. The addi- tion at the rear of the house is not original (hence the asbestos siding) and was added at an undetermined time sometime prior to 1961. The architecture of the house exhibits many of the characteristics of the craftsman-style bungalows built and popularized in the early 1900s, however with a notably steeper roof pitch. Also of note is the front corner porch topped with a low-slope shed roof. The most prominent feature of this house, however, is the decorative bargeboard on the front and side facing gables. Each with a slightly diff erent design suggesting they have been modifi ed at some point. Additionally, most of the windows are adorned with crown molding caps. Over- all, the exterior is in fair condition for a structure of this age, but it is in need of repair. The asbestos siding has chipped off in many locations and portions of the wood trim are rotten. The interior of the house is in signifi cant disrepair as well and is in need of rehabilitation. Leonard East was born in 1883 and moved to Austin in 1913, when he founded East Poultry company. Leonard and Vida East appear in the 1910 U.S. Census of Burnet County, Texas, where they rented a farm. Leonard East was 25, had been born in Texas, and was a general farmer. Vida East was 24, had been born in Texas, and had no occupation listed. They had a son, Alvin G., 3; and a daughter, Altha, almost 2. The household also …

Scraped at: May 10, 2021, 4:53 p.m.
Historic Landmark CommissionMay 10, 2021

Play audio original link

Play audio

Scraped at: May 13, 2021, 5:20 p.m.
Board of AdjustmentMay 10, 2021

A-1 BOA MINUTES MAR 8, 2021 original pdf

Thumbnail of the first page of the PDF
Page 1 of 10 pages

Board of Adjustment Minutes March 8, 2021 (Versión en español a continuación) Board of Adjustment to be held March 8, 2021 with Social Distancing Modifications Public comment will be allowed via telephone; no in-person input will be allowed. All speakers must register in advance (March 7, 2021 by noon). All public comment will occur at the beginning of the meeting. To speak remotely at the March 8, 2021 Board of Adjustment Meeting, members of the public must:  Call or email the board liaison at 512-974-2202 or elaine.ramirez@austintexas.gov no later than noon, (March 7, 2021 the day before the meeting). The following information is required: speaker name, item number(s) they wish to speak on, whether they are for/against/neutral, email address and telephone number (must be the same number that will be used to call into the meeting).  Once a request to speak has been made to the board liaison, the information to call on the day of the scheduled meeting will be provided either by email or phone call.  Speakers must call in at least 15 minutes prior to meeting start time in order to speak, late callers will not be accepted and will not be able to speak.  Speakers will be placed in a queue until their time to speak.  Handouts or other information may be emailed to elaine.ramirez@austintexas.gov by noon the day before the scheduled meeting. This information will be provided to Board and Commission members in advance of the meeting.  If the meeting is broadcast live, it may be viewed here: http://www.austintexas.gov/page/watch-atxn-live A-1/1 Minutos del Board of Adjustment FECHA de la reunion (March 8, 2021) La junta se llevará con modificaciones de distanciamiento social. Se permitirán comentarios públicos por teléfono; no se permitirá ninguna entrada en persona. Todos los oradores deben registrarse con anticipación (March 7, 2021 antes del mediodía). Todos los comentarios públicos se producirán al comienzo de la reunión. Para hablar de forma remota en la reunion March 8, 2021, los miembros del público deben:  Llame o envíe un correo electrónico al enlace de la junta en 512-974-2202 o elaine.ramirez@austintexas.gov a más tardar al mediodía (March 7, 2021 el día antes de la reunión). Se requiere la siguiente información: nombre del orador, número (s) de artículo sobre el que desean hablar, si están a favor / en contra / neutral, dirección de correo electrónico (opcional) y un número de …

Scraped at: May 4, 2021, 10:50 a.m.
Board of AdjustmentMay 10, 2021

C-1 C16-2021-0003 ADV PACKET original pdf

Thumbnail of the first page of the PDF
Page 1 of 42 pages

CITY OF AUSTIN Board of Adjustment Decision Sheet E-2 CASE NUMBER: C16-2021-0003 DATE: March 8, 2021 ___Y____Brooke Bailey ___Y____Jessica Cohen ___-____Ada Corral OUT ___-____Melissa Hawthorne (abstaining) ___-____VACANT ___Y____Don Leighton-Burwell ___Y____Rahm McDaniel ___Y____Darryl Pruett ___Y____Veronica Rivera ___-____Yasmine Smith NO SHOW ___Y____Michael Von Ohlen ___Y____Kelly Blume (Alternate) ___-____Vacant (Alternate) ___Y____Donny Hamilton (Alternate) APPLICANT: Michael Gaudini OWNER: Timothy Finley ADDRESS: 2552 GUADALUPE ST VARIANCE REQUESTED: The applicant is requesting a sign variance(s) from the Land Development Code, Section 25-10-133 (University Neighborhood Overlay Zoning District Signs), requesting a total of 12 signs on the property: (F) to allow three (3) wall signs above the second floor, one on each the northern, southern and eastern sides. (G) (1) one projecting sign for each building façade (allowed) to two (2) projecting signs (requested) on the eastern side (H) to allow for all twelve (12) signs, nine (9) on the northern, one (1)on the southern, one (1) on the eastern and one (1) on the western sides, to all be illuminated in order to provide signage for the Moxy Hotel in a “CS-CO-NP”, General Commercial Services- Conditional Overlay Combining District– Neighborhood Plan zoning district. (West University Neighborhood Plan) Note: The Land Development Code sign regulations 25-10-133 University Neighborhood Overlay Zoning Districts Signs (F) No signs may be placed above the second floor of a building, except for a non-electric sign that is engraved, cut into the building surface, or otherwise inlaid to become part of the building.(G) A wall sign is permitted if the sign complies with this subsection. (1) One projecting sign for each building façade is permitted (H) A sign may not be illuminated or contain electronic images or moving parts. C-1/1 BOARD’S DECISION: Jan 11, 2021 POSTPONED TO FEBRUARY 8, 2021 (Board member Melissa Hawthorne abstaining); Feb 8, 2021 POSTPONED TO MARCH 8, 2021; March 8, 2020 The public hearing was closed by Chair Don Leighton-Burwell, Board Member Veronica Rivera motions to Postpone to April 12, 2021; Board Member Rahm McDaniel seconds on a 9-0 vote (Board member Melissa Hawthorne abstained); POSTPONED TO APRIL 12, 2021. (RENOTICE) VARIANCE REQUESTED: RENOTICE APRIL 12, 2021 BOARD’S DECISIONFINDING: 1. The variance is necessary because strict enforcement of the Article prohibits and reasonable opportunity to provide adequate signs on the site, considering the unique features of a site such as its dimensions, landscape, or topography, because: OR, 2. The granting of this variance will not have a substantially …

Scraped at: May 4, 2021, 10:50 a.m.
Board of AdjustmentMay 10, 2021

C-1 C16-2021-0003 PRESENTATION original pdf

Thumbnail of the first page of the PDF
Page 1 of 20 pages

Austin Moxy Hotel 2552 Guadalupe Street Austin, Texas Exterior Building Signage City Presentation Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 214.265.5552 (fax) www.babendure.com Signage & Wayfinding Design Specialists 1 C-1/1/PRESENTATION F E A B C D 5 4 1 3.2 3.1 1 OVERALL SITE PLAN Scale: 1/16"=1'-0" Sign Location Plan 2 7 Existing single story building on adjacent lot (Owned by another party) Existing single story building on adjacent lot (Owned by another party) Existing single story building on adjacent lot (Owned by another party) Babendure Design Group8140 Walnut Hill Ln. #950Dallas, Texas 75231214.265.1960214.265.5552 (fax)www.babendure.comAustin Moxy HotelAustin, TexasExterior Building SignageNovember 18, 2020C-1/2/PRESENTATION 1 RESTAURANT IDENTITY Projecting Sign Box with push-through Restaurant Logo Top of Sign = 12’-8” above grade 3.1 MENU DISPLAY Located to left of windows. Top of Sign = 6’-0”above grade. 3.2 MENU DISPLAY Located to left of windows. Top of Sign = 6’-0”above grade. 4 5 PICK UP WINDOW IDENTITY Box sign with white push-through graphics. Top of Sign = 8’-0” above grade. ORDER WINDOW IDENTITY Box sign with white push-through graphics. Top of Sign = 8’-0” above grade. BILLBOARD (Owned By Another Party) 1 A B 3.1 4 3.2 5 EAST ELEVATION SCALE: 1/16” = 1’-0” 18'-3 1/2" (High Logo) 16'-3" (Low Logo) " 2 / 1 8 - ' 2 A Dimensional Letters to be Moxy pink. Top of Sign - 58’-8” above grade. " 6 - ' 1 " 2 / 1 4 - ' 2 B Dimensional Letters to be Moxy pink. Top of Sign - 14’-8” above grade. D C Dimensional Letters mounted on the canopy ledge. Color to be Moxy pink. Top of Sign - 14’-2” above grade. Projecting Sign Box with push-through graphics. Logo to be Moxy pink day. Top of Sign - 22’-8” above grade. East Elevation High and Low Level Signs 3 Babendure Design Group8140 Walnut Hill Ln. #950Dallas, Texas 75231214.265.1960214.265.5552 (fax)www.babendure.comAustin Moxy HotelAustin, TexasExterior Building SignageNovember 18, 2020C-1/3/PRESENTATION 18'-3 1/2" 16'-3 1/2" " 8 / 1 8 - ' 2 " 2 / 1 7 - ' 3 A " 8 / 5 9 " 2 / 1 2 " 1 1 - ' 1 " 4 - ' 2 LOCATION A HIGH LEVEL WALL IDENTITY FRONT ELEVATION • AREA CALCULATION: 60 SQFT Top of Sign = 58’-8” above grade. SCALE: 1/4” = 1’-0” 2 1/2" 6'-0" 5'-7" 1 3/4"Stroke Width 1" …

Scraped at: May 4, 2021, 10:51 a.m.
Board of AdjustmentMay 10, 2021

D-1 C15-2021-0027 ADV PACKET original pdf

Thumbnail of the first page of the PDF
Page 1 of 16 pages

BOA GENERAL REVIEW COVERSHEET CASE: C15-2021-0027 BOA DATE: April 12th, 2021 ADDRESS: 12905 Veronese Dr OWNER: Charles Shapiro COUNCIL DISTRICT: 8 AGENT: N/A ZONING: I-SF-2 LEGAL DESCRIPTION: AVANA PH TWO SEC TWO, BLOCK E, Lot 14, ACRES 0.2292 VARIANCE REQUEST: increase impervious cover requirements from 45% to 50% SUMMARY: erect a swimming pool ISSUES: slope of backyard ZONING LAND USES Site North South East West I-SF-2 I-SF-2 I-SF-2 I-SF-2 I-SF-2 Single-Family Single-Family Single-Family Single-Family Single-Family NEIGHBORHOOD ORGANIZATIONS: Bike Austin Circle C Homeowners Assn. Circle C Neighborhood Assn. Friends of Austin Neighborhoods Neighborhood Empowerment Foundation Save Our Springs Alliance Sierra Club, Austin Regional Group D-1/1 E N O R D A M 6 2 8 1 O R I S H A K R N PA RIDIA E M A R T M I A L C A N Z A A N A V U B P U R N I M A M I T I C V I C A E N Z A E S E N O R E V C R I C O L I A R A D N O E P L A C J A V E A TRISSINO R A M O D N U M BERNIA K A L A H A RI O RIH U E L A G A N D I A N I A E D A O M I N A T M A L L E T T O Z E N V I L L A ! ! ± SUBJECT TRACT PENDING CASE ! ! ! ! ZONING BOUNDARY NOTIFICATIONS CASE#: LOCATION: C15-2021-0027 12905 VERONESE DRIVE This product is for informational purposes and may not have been prepared for or be suitable for legal, engineering, or surveying purposes. It does not represent an on-the-ground survey and represents only the approximate relative location of property boundaries. 1 " = 667 ' This product has been produced by CTM for the sole purpose of geographic reference. No warranty is made by the City of Austin regarding specific accuracy or completeness. D-1/2 D-1/3 D-1/4 D-1/5 D-1/6 D-1/7 D-1/8 D-1/9 D-1/10 D-1/11 D-1/12 D-1/13 D-1/14 D-1/15 D-1/16

Scraped at: May 4, 2021, 10:51 a.m.
Board of AdjustmentMay 10, 2021

D-1 C15-2021-0027 AE REPORT original pdf

Thumbnail of the first page of the PDF
Page 1 of 1 page

March 30, 2021 Charles Shapiro 12905 Veronese Dr Austin TX, 78652 Property Description: Re: C15-2021-0027 Dear Charles, Austin Energy (AE) has reviewed your application for the above referenced property, requesting that the Board of Adjustment consider a variance(s) from the following sections of the Land Development Code; Section 25-2-492 (Site Development Regulations) from Impervious Cover requirements to increase from 45% (maximum allowed) to 50% (requested), in order to construct a swimming pool to an existing Single-Family residence in an “SF-2”, Single-Family Residence zoning district. Austin Energy does not have any comments for the above variance request. The address above is outside our service boundary and is served by Pedernales Electric Cooperative. I would encourage contacting your provider, to ensure that your proposed pool will meet the required electric clearances from your existing service. Thank you, Eben Kellogg, Property Agent Austin Energy Public Involvement | Real Estate Services 2500 Montopolis Drive Austin, TX 78741 (512) 322-6050

Scraped at: May 4, 2021, 10:51 a.m.
Board of AdjustmentMay 10, 2021

D-1 C15-2021-0027 PRESENTATION original pdf

Thumbnail of the first page of the PDF
Page 1 of 6 pages

12905 Veronese Dr Impervious cover variance request May 10 2021 Charles Shapiro D-1/1/PRESENTATION Property hardship - 18% backyard slope D-1/2/PRESENTATION Front view of 18% slope 12’ to first floor (grade level) 21 steps to first floor Front yard inaccessible/unsafe D-1/3/PRESENTATION Back view of 18% slope Only small section usable (lesser slope) Back porch steps down to 18% slope D-1/4/PRESENTATION Plans More limestone terracing (similar to front yard done by builder) Wood deck around pool (versus concrete decking) to minimize impervious cover impact Plans reviewed/approved by both neighbors D-1/5/PRESENTATION Questions Thank you for the time D-1/6/PRESENTATION

Scraped at: May 4, 2021, 10:51 a.m.
Board of AdjustmentMay 10, 2021

D-10 C15-2021-0051 ADV PACKET PART1 original pdf

Thumbnail of the first page of the PDF
Page 1 of 42 pages

BOA GENERAL REVIEW COVERSHEET CASE: C15-2021-0051 BOA DATE: May 10th, 2021 ADDRESS: 106 & 108 Comal St OWNER: Peter Peveto COUNCIL DISTRICT: 3 AGENT: N/A ZONING: SF-3-NP (East Cesar Chavez) LEGAL DESCRIPTION: TRT C OLT 20 DIVISION O & TRT B OLT 20 DIVISION O VARIANCE REQUEST: decrease front yard setback from 25 ft. to 15 ft. and decrease rear yard setback from 10 ft. to 5 ft. SUMMARY: erect a Single-Family residence ISSUES: two small lots Site North South East West SF-3-NP SF-3-NP CS-MU-CO-NP CS-MU-CO-NP SF-3-NP ZONING LAND USES Single-Family Single-Family General Commercial Services-Mixed Use General Commercial Services-Mixed Use Single-Family NEIGHBORHOOD ORGANIZATIONS: Austin Independent School District Austin Lost and Found Pets Austin Neighborhoods Council Barrio Unido Neighborhood Assn. Bike Austin Capital Metro Del Valle Community Coalition East Austin Conservancy East Cesar Chavez Neighborhood Association East Cesar Chavez Neighborhood Plan Contact Team El Concilio Mexican-American Neighborhoods Friends of Austin Neighborhoods Greater East Austin Neighborhood Association Guadalupe Neighborhood Development Corporation Homeless Neighborhood Association Neighborhood Empowerment Foundation Neighbors United for Progress Preservation Austin SELTexas Sierra Club, Austin Regional Group Tejano Town D-10/1 ! ! ± SUBJECT TRACT PENDING CASE ! ! ZONING BOUNDARY NOTIFICATIONS CASE#: LOCATION: C15-2021-0051 106 & 108 COMAL STREET This product is for informational purposes and may not have been prepared for or be suitable for legal, engineering, or surveying purposes. It does not represent an on-the-ground survey and represents only the approximate relative location of property boundaries. 1 " = 208 ' This product has been produced by CTM for the sole purpose of geographic reference. No warranty is made by the City of Austin regarding specific accuracy or completeness. D-10/2 D-10/3 D-10/4 D-10/5 D-10/6 D-10/7 D-10/8 D-10/9 D-10/10 D-10/11 D-10/12 D-10/13 D-10/14 D-10/15 D-10/16 D-10/17 D-10/18 D-10/19 D-10/20 D-10/21 D-10/22 D-10/23 D-10/24 D-10/25 D-10/26 D-10/27 D-10/28 D-10/29 D-10/30 D-10/31 D-10/32 D-10/33 D-10/34 D-10/35 D-10/36 D-10/37 D-10/38 D-10/39 D-10/40 D-10/41 D-10/42

Scraped at: May 4, 2021, 10:51 a.m.
Board of AdjustmentMay 10, 2021

D-10 C15-2021-0051 ADV PACKET PART2 original pdf

Thumbnail of the first page of the PDF
Page 1 of 16 pages

D-10/43 D-10/44 D-10/45 D-10/46 D-10/47 D-10/48 D-10/49 D-10/50 D-10/51 D-10/52 D-10/53 D-10/54 D-10/55 D-10/56 D-10/57 D-10/58

Scraped at: May 4, 2021, 10:52 a.m.
Board of AdjustmentMay 10, 2021

D-10 C15-2021-0051 ADV PACKET PART3 original pdf

Thumbnail of the first page of the PDF
Page 1 of 39 pages

D-10/59 D-10/60 D-10/61 D-10/62 D-10/63 D-10/64 D-10/65 D-10/66 D-10/67 D-10/68 D-10/69 D-10/70 D-10/71 D-10/72 D-10/73 D-10/74 D-10/75 D-10/76 D-10/77 D-10/78 D-10/79 D-10/80 D-10/81 D-10/82 D-10/83 D-10/84 D-10/85 D-10/86 D-10/87 D-10/88 D-10/89 D-10/90 D-10/91 D-10/92 D-10/93 D-10/94 D-10/95 D-10/96 D-10/97

Scraped at: May 4, 2021, 10:52 a.m.
Board of AdjustmentMay 10, 2021

D-10 C15-2021-0051 ADV PACKET PART4 original pdf

Thumbnail of the first page of the PDF
Page 1 of 26 pages

D-10/98 D-10/99 D-10/100 D-10/101 D-10/102 D-10/103 D-10/104 D-10/105 D-10/106 D-10/107 D-10/108 D-10/109 D-10/110 D-10/111 D-10/112 D-10/113 D-10/114 D-10/115 D-10/116 D-10/117 D-10/118 D-10/119 D-10/120 D-10/121 D-10/122 D-10/123

Scraped at: May 4, 2021, 10:53 a.m.
Board of AdjustmentMay 10, 2021

D-10 C15-2021-0051 ADV PACKET PART5 original pdf

Thumbnail of the first page of the PDF
Page 1 of 3 pages

D-10/124 D-10/125 D-10/126

Scraped at: May 4, 2021, 10:53 a.m.
Board of AdjustmentMay 10, 2021

D-10 C15-2021-0051 AE REPORT original pdf

Thumbnail of the first page of the PDF
Page 1 of 1 page

May 3, 2021 Peter Pevoto 106 & 108 Comal St Austin TX, 78702 Property Description: TRT C OLT 20 DIVISION O Re: C15-2021-0051 Dear Peter, Austin Energy (AE) has reviewed your application for the above referenced property, requesting that the Board of Adjustment consider a variance(s) from the following sections of the Land Development Code; 25-2-492 (Site Development Regulations) from setback requirements to:   decrease the minimum Front Yard Setback from 25 feet (required) to 15 feet (requested) and decrease the minimum Rear Yard Setback from 10 feet (required) to 5 feet (requested) in order to erect a Single Family Residence in a “SF-3-NP”, Single-Family-Neighborhood Plan zoning district (East Cesar Chavez Neighborhood Plan). Austin Energy does not oppose the above setback variance request, for your proposed structures to be constructed at the above addresses, provided any proposed and existing improvements comply with Austin Energy’s clearance criteria requirements, the National Electric Safety Code and OSHA. Any removal or relocation of existing electric facilities will be at owners /applicants’ expense. Please use this link to be advised of our clearance and safety requirements which are additional conditions of review action: https://austinenergy.com/wcm/connect/8bb4699c-7691-4a74-98e7- 56059e9be364/Design+Criteria+Manual+Oct+2015.pdf?MOD=AJPERES the above If you have any questions about the following comments, please contact my office. Thank you, Eben Kellogg, Property Agent Austin Energy Public Involvement | Real Estate Services 2500 Montopolis Drive Austin, TX 78741 (512) 322-6050

Scraped at: May 4, 2021, 10:53 a.m.
Board of AdjustmentMay 10, 2021

D-10 C15-2021-0051 PRESENTATION original pdf

Thumbnail of the first page of the PDF
Page 1 of 7 pages

1510 E 2nd St - 1 & 2 1513 E 2nd St - A & B D-10/1/PRESENTATION 1513 E 2nd St – Units A & B (Next door to 106/108 Comal) New construction 1,143sf primary house w/ attached 1,156sf Secondary Apartment. Front yard setback averaging used for 12ft setback facing E 2nd St. There is a 15ft setback from Comal St and 5ft setback from the side yard neighbor. D-10/2/PRESENTATION D-10/3/PRESENTATION 1510 E 2nd St – Unit 1 New construction 1,790sf main house set back 15ft from Comal and 5ft from the side yard neighbor. 1510 E 2nd St – Unit 2 New construction 1,080sf Accessory Dwelling Unit with front door facing Comal St. The front of the unit is set back 15ft from Comal and the back of the unit is set back 5ft from the side yard neighbor. D-10/4/PRESENTATION D-10/5/PRESENTATION 99 COMAL ST Existing non-compliant 600sf home facing Comal with front yard setback of 10 ft or less. 85 COMAL ST Existing non-compliant 807sf home facing Comal permitted for addition of 695sf. Front yard setback is 10ft or less. D-10/6/PRESENTATION D-10/7/PRESENTATION

Scraped at: May 4, 2021, 10:53 a.m.
Board of AdjustmentMay 10, 2021

D-2 C15-2021-0028 ADV PACKET original pdf

Thumbnail of the first page of the PDF
Page 1 of 14 pages

BOA GENERAL REVIEW COVERSHEET CASE: C15-2021-0028 BOA DATE: May 10th, 2021 ADDRESS: 3406 Gonzales St OWNER: David Morgan COUNCIL DISTRICT: 3 AGENT: N/A ZONING: SF-3-NP (Govalle) LEGAL DESCRIPTION: E 63.2FT OF S150FT LOT 1 BLK 4 DIV A RESUB LOT 3-6 LATTIMORE SUBD VARIANCE REQUEST: SUMMARY: erect a Two-Family Residential Use ISSUES: protected trees Site SF-3-NP North LR-MU-CO-NP SF-3-NP South SF-3-NP East SF-3-NP West ZONING LAND USES Single-Family Neighborhood Commercial-Mixed Use Single-Family Single-Family Single-Family NEIGHBORHOOD ORGANIZATIONS: Austin Independent School District Austin Lost and Found Pets Austin Neighborhoods Council Bike Austin Del Valle Community Coalition East Austin Conservancy El Concilio Mexican-American Neighborhoods Friends of Austin Neighborhoods Govalle Neighborhood Association Govalle/Johnston Terrace Neighborhood Plan Contact Team Guadalupe Neighborhood Development Corporation Homeless Neighborhood Association Neighborhood Empowerment Foundation Neighbors United for Progress Preservation Austin SELTexas Sierra Club, Austin Regional Group D-2/1 Y R E L TIL S E L L E R S O RIC E H C R E T N U G Y N T O W O N GONZALES 7 T H E L A D G RIN P S N E L L A HOLTON HIDALGO ! ! ± SUBJECT TRACT PENDING CASE ! ! ! ! ZONING BOUNDARY NOTIFICATIONS CASE#: LOCATION: C15-2021-0028 3406 GONZALES STREET This product is for informational purposes and may not have been prepared for or be suitable for legal, engineering, or surveying purposes. It does not represent an on-the-ground survey and represents only the approximate relative location of property boundaries. 1 " = 168 ' This product has been produced by CTM for the sole purpose of geographic reference. No warranty is made by the City of Austin regarding specific accuracy or completeness. D-2/2 D-2/3 D-2/4 D-2/5 D-2/6 D-2/7 D-2/8 D-2/9 D-2/10 D-2/11 D-2/12 LOT SIZE Name LOT MAXIMUM FAR Area 9,877 SF 3,950 SF TREE SCHEDULE # TREE TYPE PROTECTED TREE DIAMETER 7884 7885 7886 7887 7888 7889 7890 7891 7892 7893 A YES SPANISH OAK NO TALLOW YES PECAN YES PECAN TEXAS ASH NO MULBERRY NO NO PECAN YES PECAN NO PECAN YES PECAN YES PECAN 1' - 9" 1' - 2" 2' - 6" 1' - 10" 1' - 2" 0' - 9" 1' - 5" 1' - 7" 1' - 2" 2' - 7" 1' - 10" KEYNOTE LEGEND 508 509 530 531 533 1/4 CRITICAL ROOT ZONE - NO CUT OR FILL WITHIN THIS AREA 1/2 CRITICAL ROOT ZONE - …

Scraped at: May 4, 2021, 10:54 a.m.
Board of AdjustmentMay 10, 2021

D-2 C15-2021-0028 AE REPORT original pdf

Thumbnail of the first page of the PDF
Page 1 of 1 page

May 3, 2021 James Smith 3406 Gonzales St Austin TX, 78702 Re: C15-2021-0028 Property Description: E 63.2FT OF S150FT LOT 1 BLK 4 DIV A RESUB LOT 3-6 LATTIMORE SUBD Dear James, Austin Energy (AE) has reviewed your application for the above referenced property, requesting that the Board of Adjustment consider a variance(s) from the following sections of the Land Development Code; Section 25-2-774 (Two-Family Residential Use) (C) (2) (a) which requires an Accessory Dwelling Unit to be located at least 10 feet to the rear or side of the principal structure (required), to 6 ft. 7 in. from the principal structure (requested) in order to erect a Single-Family residence in an “SF-3-NP”, Single- Family Residence-Neighborhood Plan zoning district. (Govalle Neighborhood Plan) Austin Energy does not oppose the above setback variance for an ADU, provided any proposed and existing improvements follow Austin Energy’s clearance criteria requirements, the National Electric Safety Code and OSHA. Any removal or relocation of existing electric facilities will be at owners /applicants’ expense. Please use this link to be advised of our clearance and safety requirements which are additional conditions of review action: https://austinenergy.com/wcm/connect/8bb4699c-7691-4a74-98e7- 56059e9be364/Design+Criteria+Manual+Oct+2015.pdf?MOD=AJPERES the above If you have any questions about the following comments, please contact my office. Thank you, Eben Kellogg, Property Agent Austin Energy Public Involvement | Real Estate Services 2500 Montopolis Drive Austin, TX 78741 (512) 322-6050

Scraped at: May 4, 2021, 10:54 a.m.
Board of AdjustmentMay 10, 2021

D-2 C15-2021-0028 PRESENTATION original pdf

Thumbnail of the first page of the PDF
Page 1 of 6 pages

LOT SIZE Name LOT MAXIMUM FAR Area 9,877 SF 3,950 SF TREE SCHEDULE # TREE TYPE PROTECTED TREE DIAMETER 7884 7885 7886 7887 7888 7889 7890 7891 7892 7893 A YES SPANISH OAK NO TALLOW YES PECAN YES PECAN TEXAS ASH NO MULBERRY NO NO PECAN YES PECAN NO PECAN YES PECAN YES PECAN 1' - 9" 1' - 2" 2' - 6" 1' - 10" 1' - 2" 0' - 9" 1' - 5" 1' - 7" 1' - 2" 2' - 7" 1' - 10" KEYNOTE LEGEND 508 509 530 531 533 1/4 CRITICAL ROOT ZONE - NO CUT OR FILL WITHIN THIS AREA 1/2 CRITICAL ROOT ZONE - NO CUT OR FILL GREATER THAN 4" WITHIN THIS AREA EXISTING BUILDING OVERLAPS 1/4" CRZ - NO DEMO IN THIS AREA EXISTING BUILDING OVERLAPS 1/2" CRZ - NO DEMO IN THIS AREA NEW PRIMARY STRUCTURE TO BE LOCATED A MINIMUM OF 10'-0" TO THE REAR OF EXISTING ADU 25' - 0" PROPERTY LINE PROPERTY LINE 7888 - TEXAS ASH 14"Ø NO SETBACK LINE SETBACK LINE EXISTING DRIVE 7889 - MULBERRY 9"Ø NO " 0 - ' 5 7890 - PECAN 17"Ø NO 7891 - PECAN 19"Ø YES 7885 - TALLOW 14"Ø NO 7886 - PECAN 30"Ø YES 220SF DEMO OF SINGLE STORY 10' - 0" 7892 - PECAN 14"Ø NO 509 508 E E N N I I L L G G N N D D L L I I U U B B I I K K C C A A B B T T E E S S T T N N O O R R F F 7887 - PECAN 22"Ø YES 509 508 531 EXISTING FRONT PORCH 1100SF EXISTING SINGLE STORY PROPOSED TO BE CLASSIFIED AS ADU NEW PRIMARY DWELLING IS PROPOSED TO BE CONSTRUCTED IN THIS AREA AT THE REAR OF THE LOT • PRIMARY DWELLING TO BE CONSRUCTED A MINIMUM OF 10'-0" BEHIND EXISTING STRUCTURE. FOOTPRINT TO AVOID 1/2 AND 1/4 CRZ FOOTPRINT TO REMAIN INSIDE SETBACK LINES FAR FOR PRIMARY STRUCTURE NOT TO EXCEED 2850SF FOR A SITE FAR NOT TO EXCEED 40% OR 3950SF BUILDING ENVELOPE TO REMAIN INSIDE MCMANSION TENT • • • • 533 509 530 508 7893 - PECAN 31"Ø YES " " 0 0 - - ' ' 5 5 SETBACK LINE SETBACK LINE PROPERTY LINE PROPERTY LINE " " 0 0 - - ' ' 5 …

Scraped at: May 4, 2021, 10:54 a.m.
Board of AdjustmentMay 10, 2021

D-3 C15-2021-0032 ADV PACKET original pdf

Thumbnail of the first page of the PDF
Page 1 of 17 pages

BOA GENERAL REVIEW COVERSHEET CASE: C15-2021-0032 BOA DATE: April 12th, 2021 ADDRESS: 1601 Brackenridge St OWNER: Happy East Homes COUNCIL DISTRICT: 9 AGENT: Mark Hutchinson ZONING: SF-3-NP (South River City) LEGAL DESCRIPTION: LOT 1 BLK 12G FAIRVIEW PARK PRORATE FROM 09/18/2019 - 12/31/19 VARIANCE REQUEST: decrease rear yard setback of a thru lot from 25 ft. to 5 ft. SUMMARY: erect a Secondary Dwelling Unit ISSUES: thru lot, corner lot, and protected tree ZONING LAND USES Site North South East West SF-3-NP SF-3-NP SF-3-NP SF-3-NCCD-NP SF-3-NP Single-Family Single-Family Single-Family Single-Family Single-Family NEIGHBORHOOD ORGANIZATIONS: Austin Independent School District Austin Lost and Found Pets Austin Neighborhoods Council Bike Austin Friends of Austin Neighborhoods Greater South River City Combined Neighborhood Plan Contact Team Homeless Neighborhood Association Neighborhood Empowerment Foundation Preservation Austin SELTexas Sierra Club, Austin Regional Group South Central Coalition South River City Citizens Assn. Zoning Committee of South River City Citizens D-3/1 PARK I H L L S I D E G NIN W E N ELIZABETH MONROE E G D I R N E K C A R B E K A R D N O S R E K NIC MILTON ! ! ± SUBJECT TRACT PENDING CASE ! ! ! ! ZONING BOUNDARY ANNIE NOTIFICATIONS CASE#: LOCATION: C15-2021-0032 1601 BRACKENRIDGE STREET This product is for informational purposes and may not have been prepared for or be suitable for legal, engineering, or surveying purposes. It does not represent an on-the-ground survey and represents only the approximate relative location of property boundaries. 1 " = 168 ' This product has been produced by CTM for the sole purpose of geographic reference. No warranty is made by the City of Austin regarding specific accuracy or completeness. D-3/2 Board of Adjustment General/Parking Variance Application DevelopmentATX.com (cid:95) Phone: 311 (or 512-974-2000 outside Austin) For submittal and fee information, see austinte(cid:91)as.gov/digitaldevelopment WARNING: F(cid:76)(cid:79)(cid:76)(cid:81)g (cid:82)f (cid:87)(cid:75)(cid:76)(cid:86) a(cid:83)(cid:83)ea(cid:79) (cid:86)(cid:87)(cid:82)(cid:83)(cid:86) a(cid:79)(cid:79) affec(cid:87)ed c(cid:82)(cid:81)(cid:86)(cid:87)(cid:85)(cid:88)c(cid:87)(cid:76)(cid:82)(cid:81) ac(cid:87)(cid:76)(cid:89)(cid:76)(cid:87)(cid:92). This application is a fillable PDF that can be completed electronicall(cid:92). To ensure (cid:92)our information is saved, click here to Save the form to (cid:92)our computer, then open (cid:92)our cop(cid:92) and continue. The Tab ke(cid:92) ma(cid:92) be used to navigate to each field; Shift + Tab moves to the previous field. The Enter ke(cid:92) activates links, emails, and buttons. Use the Up & Do(cid:90)n Arro(cid:90) ke(cid:92)s to scroll through drop-do(cid:90)n lists and check bo(cid:91)es, and hit Enter to make a selection. The application must …

Scraped at: May 4, 2021, 10:55 a.m.
Board of AdjustmentMay 10, 2021

D-3 C15-2021-0032 AE REPORT original pdf

Thumbnail of the first page of the PDF
Page 1 of 1 page

March 30, 2021 Jessica Braun 1601 Brackenridge St Austin TX, 78704 Re: C15-2021-0032 Property Description: LOT 1 BLK 12G FAIRVIEW PARK PRORATE FROM 09/18/2019 - 12/31/19 Dear Jessica, Austin Energy (AE) has reviewed your application for the above referenced property, requesting that the Board of Adjustment consider a variance(s) from the following sections of the Land Development Code; from Section 25-2-515 (Rear Yard of a Through Lot) from setback requirements to decrease the minimum rear yard setback from 25 feet (required) to 5 feet (requested) in order to erect a secondary dwelling unit in an “SF-3-NP”, Single-Family Residence-Neighborhood Plan zoning district. (South River City Neighborhood Plan); Austin Energy does not oppose the above variance request provided any proposed and existing improvements follow Austin Energy’s clearance criteria requirements, the National Electric Safety Code and OSHA. Any removal or relocation of existing electric facilities will be at owners /applicants’ expense. Please use this link to be advised of our clearance and safety requirements which are additional conditions review action: https://austinenergy.com/wcm/connect/8bb4699c-7691-4a74-98e7- of 56059e9be364/Design+Criteria+Manual+Oct+2015.pdf?MOD=AJPERES the above Thank you for contacting Austin Energy. Eben Kellogg, Property Agent Austin Energy Public Involvement | Real Estate Services 2500 Montopolis Drive Austin, TX 78741 (512) 322-6050

Scraped at: May 4, 2021, 10:55 a.m.
Board of AdjustmentMay 10, 2021

D-3 C15-2021-0032 PRESENTATION original pdf

Thumbnail of the first page of the PDF
Page 1 of 10 pages

NEIGHBORHOOD MAP D-3/1/PRESENTATION SURROUNDING STRUCTURES D-3/2/PRESENTATION 1712 DRAKE AVE. / 1711 BRACKENRIDGE ST. 1710 DRAKE AVE. / 1709 BRACKENRIDGE ST. 1707 BRACKENRIDGE ST. 1705 BRACKENRIDGE ST. SURROUNDING STRUCTURES D-3/3/PRESENTATION 1613 BRACKENRIDGE ST. 1611 BRACKENRIDGE ST. 1607 BRACKENRIDGE ST. 1605 BRACKENRIDGE ST. SURROUNDING STRUCTURES D-3/4/PRESENTATION EAST MONROE STREET (RIGHT-OF-WAY VARIES) CONCRETE WALK 548' 549' 25" LYGUSTRUM 550' 1/2 CRZ . E . O U.P. O . E . ) ' 0 0 . 6 4 ( ' W " 0 0 5 0 ° 2 1 S CURB WATER METER STOP SIGN 551' LOT 6304sf CURRENT DEVELOPABLE AREA 243 SF K C A B T E S ' 5 2 1/2 CRZ EXISTING PRIMARY DWELLING ADDITION 15' SETBACK 552' U.P. 5' SETBACK 24" PECAN 553' 12'-6" 10'-0" 25'-8 1/2" 10'-2" 38'-5" 22'-6" 15'-3 1/2" 25'-0" 15'-0" BENCHMARK ELEV = 547.74' STOP SIGN B R U C T E L N I ) ' 0 6 ( T E E R T S E G D R N E K C A R B I E T E R C N O C K L A W ) ' 0 0 . 6 4 ( E " 9 1 4 0 ° 2 1 N ' S77°59'26"E (137.06') WALKWAY (77sf) O.E. FRONT PORCH 322sf ' 8 . 3 5 5 = . . E F F . GAS METER AC 9sf K C A B T E S ' 5 2 N77°59'26"W (137.05') SITE PLAN - EXISTING SCALE: 1" = 20'-0" " 0 - ' 5 1 " 0 1 - ' 5 1 " 2 - ' 0 1 ) ' 0 6 ( E U N E V A E K A R D B R U C O . E . N D-3/5/PRESENTATION BENCHMARK ELEV = 547.74' STOP SIGN B R U C T E L N I ) ' 0 6 ( T E E R T S E G D R N E K C A R B I E T E R C N O C K L A W ) ' 0 0 . 6 4 ( E " 9 1 4 0 ° 2 1 N ' EAST MONROE STREET (RIGHT-OF-WAY VARIES) CONCRETE WALK 548' CURB WATER METER STOP SIGN 549' 25" LYGUSTRUM 550' 1/2 CRZ S77°59'26"E (137.06') WALKWAY (77sf) O.E. FRONT PORCH 322sf ' 8 . 3 5 5 = . . E …

Scraped at: May 4, 2021, 10:55 a.m.
Board of AdjustmentMay 10, 2021

D-4 C15-2021-0033 ADV PACKET PART1 original pdf

Thumbnail of the first page of the PDF
Page 1 of 16 pages

D-4/1 D-4/2 D-4/3 D-4/4 D-4/5 D-4/6 D-4/7 D-4/8 D-4/9 D-4/10 D-4/11 D-4/12 D-4/13 D-4/14 D-4/15 D-4/16

Scraped at: May 4, 2021, 10:55 a.m.
Board of AdjustmentMay 10, 2021

D-4 C15-2021-0033 ADV PACKET PART2 original pdf

Thumbnail of the first page of the PDF
Page 1 of 10 pages

D-4/17 D-4/18 D-4/19 D-4/20 D-4/21 D-4/22 D-4/23 D-4/24 D-4/25 N L R E D D U R G C M T R O F I ) S E R A V W O R ( K C A B T E S T N O R F " 0 - ' 5 2 I ) S E R A V W O R ( I N L N S S E L D R A Y T N O R F ' 5 2 T N E R R U C K C A B T E S K C A B T E S D R A Y T N O R F ' 2 1 D E S O P O R P 12' - 0" 25' - 0" NO REFERENCE ISSUED D-4/26

Scraped at: May 4, 2021, 11 a.m.