Historic Landmark Commission Homepage

RSS feed for this page

Feb. 28, 2022

B.1.b - 2402 San Gabriel St - Preserve the Jacob Fontaine Gold Dollar Building original pdf

Thumbnail of the first page of the PDF
Page 1 of 14 pages

2/21/22, 11:17 AM Preserve the Jacob Fontaine Gold Dollar Building – RETELLING CENTRAL TEXAS HISTORY RETELLING CENTRAL TEXAS HISTORY https://ctxretold.org/preserve-the-jacob-fontaine-gold-dollar-building/ 1/14 2/21/22, 11:17 AM Preserve the Jacob Fontaine Gold Dollar Building – RETELLING CENTRAL TEXAS HISTORY Preserve the Jacob Fontaine Gold Dollar Building As the last remaining structure of Wheatville, a mostly forgotten community of persons who were formerly enslaved in Texas and across the US, the Jacob Fontaine Gold Dollar Building at 2402 San Gabriel Street is an important physical foundation for Black social memory in Austin. While it is a City of Austin Landmark, the structure has endured significant physical changes over the years—alterations that are nevertheless of historic age, part of the building’s historic significance. This statement reanimates and substantiates the history of the structure and the freed-person community originally surrounding it, establishing the Gold Dollar Building as a valuable site for the city’s Black heritage and collective historical memory. In doing so, it makes the case for its treatment as a commemorative space and calls into question allowing further physical modifications to the structure. During a time when Austin’s Black population was at about 36%, several white men who owned property in Division D began to sell lots to freedmen. Joseph Caruthers, a freedman from North or South Carolina, acquired property in outlot 46, including the site of present-day 900 West 24 Street, from Colonel John M. Thomas in December 1868. Shortly after, in the th spring and summer of 1869, a freedman from Arkansas, James Wheat, acquired three parcels from Thomas, also in outlot 46 and including present-day 2409 San Gabriel. The Wheat family became the namesake, if not the founders, of a freedom colony or freedmen’s community called Wheatville. Other Black folks soon also bought small lots in the area—including George Franklin, who bought property at present-day 2402 San Gabriel St. that same year and set up a wagon park on it—and the self-directed community began to grow. The increase in that property’s value indicates that Franklin developed it in some way, possibly with a one-story, stone building with a lean-to (FIG 1). https://ctxretold.org/preserve-the-jacob-fontaine-gold-dollar-building/ 2/14 2/21/22, 11:17 AM Preserve the Jacob Fontaine Gold Dollar Building – RETELLING CENTRAL TEXAS HISTORY Figure 1 – Gold Dollar Building 1869-1875. The earliest construction on the site by George Franklin may have been a simple barnlike stone building against an existing stable or other wooden structures. The stone …

Scraped at: Feb. 24, 2022, 3:50 p.m.
Feb. 28, 2022

B.2.0 - 207 W 33rd St original pdf

Thumbnail of the first page of the PDF
Page 1 of 3 pages

HISTORIC LANDMARK COMMISSION APPLICATION FOR A CERTIFICATE OF APPROPRIATENESS FEBRUARY 28, 2021 HR-2021-202373 ALDRIDGE PLACE HISTORIC DISTRICT 207 W. 33RD STREET B.2 – 1 PROPOSAL Replace roof. PROJECT SPECIFICATIONS DESIGN STANDARDS 5.2.5: Roofs Replace existing shingle roof with standing-seam metal in brown color. No slope change is proposed. The Aldridge Place Design Standards are used to evaluate projects within the historic district. The following standards apply to the proposed project: 1. Retain the original roof pitches and profiles on the building. Avoid changes to roofs on the front of the building. Avoid adding to the eave height of original roofs, especially at the front of the structure. Retain historic dormers. The proposed project does not modify existing roof pitches or profiles. 2. In replacing roof materials, consider first the use of the original material, then the use of a product that resembles the original material, such as a fiberglass or other energy-efficient shingle. metal roofs are also acceptable. Preserve original gable/attic vents and roof brackets. The proposed project replaces a shingle roof with metal. Summary The project meets the applicable standards. PROPERTY EVALUATION The property contributes to the Aldridge Place Historic District. STAFF RECOMMENDATION Approve the application, encouraging the applicant to choose a shingle replacement over standing-seam metal for enhanced compatibility. LOCATION MAP B.2 – 2 PROPERTY INFORMATION B.2 – 3 Source: Applicant, 2022

Scraped at: Feb. 24, 2022, 3:51 p.m.
Feb. 28, 2022

B.2.1 - 207 W 33rd St - Photos original pdf

Thumbnail of the first page of the PDF
Page 1 of 5 pages

207 West 33rd St. Roof

Scraped at: Feb. 24, 2022, 3:51 p.m.
Feb. 28, 2022

B.2.2 - 207 W 33rd St - Applicant Presentation original pdf

Thumbnail of the first page of the PDF
Page 1 of 12 pages

207 West 33rd Street in Aldridge Place Historic District Replace Composition Shingle Roof with Standing Seam Metal Roof •Front gabled house with front gabled porch, meaning visibility of roof from the front is limited •Like all the composition shingled houses in my neighborhood, my roof needs replacement •Proposed roof would be brown-colored standing seam metal West View East View Only Similar Request to HLC from 2019 through 2021 4205 Avenue F Approved on Consent September 28, 2020 (Its roof has greater visibility than mine) Climate-Related Environmental Reasons for Request • Heat and hail are primary reasons • In Austin, eight of the top ten years by number of days over 100 degrees have been since 2000 • The past seven years were Earth's warmest on record "by a clear margin" • A team of Canadian researchers estimates that stronger storms, combined with larger updrafts, will lead to the production of bigger hailstones in parts of North America Composition Shingle Limitations • Thermal changes cause composition shingles to break down as they heat up and cool down • Their lifespan is 20 to 25 years in an average climate (Austin is a hotter than average climate) • When replaced, the existing shingles must be discarded. They take up landfill space and are a waste of resources Advantages of Metal Roofs • Metal roof are made, in part, of recycled materials • Metal roofs can be recycled if replacement is needed • Metal roofs have an average lifespan of 50 to 70 years More Advantages of Metal Roofs • Metal roofs are more energy-efficient because of their reflective qualities (thanks to microscopic ceramics bits in the paint that reflect heat) • They absorb less heat during the day and reduce heat transmission to a home’s interior • Because they don’t absorb as much heat as shingles, metal roofs cool down faster at night. They don’t contribute as much to the heat island effect that exists in Central Austin Aldridge Place Design Standards 5.2.5: Roofs (Identical to Hyde Park Historic District’s Standards) 1. Retain the original roof pitches and profiles on the building. Avoid changes to roofs on the front of the building.… 2. In replacing roof materials, consider first the use of the original material, then use a product that resembles the original material… Metal roofs are also acceptable… Based on debris in my attic, the original roof cover was cedar shake …

Scraped at: Feb. 24, 2022, 3:51 p.m.
Feb. 28, 2022

B.3.0 - 3908 Avenue H original pdf

Thumbnail of the first page of the PDF
Page 1 of 8 pages

HISTORIC LANDMARK COMMISSION APPLICATION FOR A CERTIFICATE OF APPROPRIATENESS FEBRUARY 28, 2022 HR-2022-002112 HYDE PARK HISTORIC DISTRICT 3908 AVENUE H B.3 – 1 PROPOSAL PROJECT SPECIFICATIONS Add front porch, construct two-story addition, replace siding, replace roof, replace all windows, and add chimney to ca. 1953 contributing house. Replace siding and install new door at garage. 1) Demolish front of residence and construct a full-width front porch. The proposed porch includes a gabled roof supported by tapered columns atop brick veneer piers. 2) Replace asbestos shingle siding with fiber-cement siding. 3) Replace composition shingle roof with new composition shingles. 4) Replace all original windows with 4:1 double-hung composite windows. 5) Add a brick veneer chimney to north elevation 6) Demolish rear screened porch and construct a two-story addition directly above the existing ridgeline. The proposed addition features a compound cross-gabled roof, 4:1 and 2:1 single-hung windows, and a covered back porch. 7) Remodel garage, replacing existing asbestos shingle siding with fiber cement, replacing the roof with new composition shingles, and adding a door to south elevation. ARCHITECTURE One-story house with Minimal Traditional stylistic influences, clad in asbestos shingle siding. Its cross-gabled roof shelters a partial-width inset porch with decorative metal supports and handrails. Fenestration includes 2:2 screened aluminum windows and a multi-light aluminum picture window, as well as an original partially glazed and louvered screen door. DESIGN STANDARDS The Hyde Park Design Standards are used to evaluate projects within the historic district. The following standards apply to the proposed project: 1. General Standards 1.2: Retention of Historic Style. Respect the historic style of existing structures and retain their historic features, including character-defining elements and building scale. The proposed project removes character-defining elements of the house, including but not limited to porch form and fenestration. 1.3: Avoidance of False Historicism. Respect each contributing structure as an example of the architecture of its time. Do not make alterations that have no historic basis, such as the addition of gingerbread trim to a 1920s bungalow. Do not give an existing contributing structure a “historic” appearance it never had. The proposed project removes original material and adds Craftsman-style elements to a house displaying Minimal Traditional stylistic influences. The project also adds a masonry chimney, which is not appropriate to the style of the existing house. 1.4: Appropriate Treatment Options for Contributing or Potentially Contributing Structures. 1. Preserve the historic fabric: Repair deteriorated historic features and …

Scraped at: Feb. 24, 2022, 3:51 p.m.
Feb. 28, 2022

B.3.1 - 3908 Avenue H - Plans and photos original pdf

Thumbnail of the first page of the PDF
Page 1 of 24 pages

WINDSOR RESIDENCE 3908 Avenue H Austin, Texas 78751 Total Conditioned Building area for Addition and Renovations of existing Residence 2,396 SQ. FT. 100% Permit Set - 11/15/2021 TEAM MEMBERS OWNER / CONTACT STEPHAN WINDSOR 3908 AVENUE H AUSTIN, TEXAS 78751 ARCHITECT OF RECORD DOUG FREY FREY ARCHITECTS, INC. P.O. BOX 5742 AUSTIN, TEXAS 78763 dfrey@freyarchitects.com (512) 330-0334 STRUCTURAL ENGINEER SAMUEL COVEY P.E. FORT STRUCTURES PC 2235 EAST 6TH ST. #105 AUSTIN, TEXAS 78702 sam@fortstructures.com (512) 817-9264 GENERAL CONTRACTOR PROJECT INFORMATION CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH APPLICABLE CODES OR STATUS WHETHER OR NOT SPECIFICALLY REFERENCED IN THE CONSTRUCTION DOCUMENTS • • • • • INTERNATIONAL RESIDENTIAL CODE, 2021 EDITION, AND LOCAL AUSTIN AMENDMENTS INTERNATIONAL ENERGY CONSERVATION CODE, 2021 EDITION, AND LOCAL AUSTIN AMENDMENTS CITY OF AUSTIN LDC CHAPTER 25-2 SUB-CHAPTER F CITY OF AUSTIN LDC CHAPTER 25-6 APPENDIX A PARKING REQUIRMENTS CITY OF AUSTIN 2012 ORDINANCE #20120112-086 PART 8, SECTION 8 SCOPE OF WORK SHEET INDEX SHEET INDEX SHEET INDEX Sheet Name Sheet Name Sheet Number Sheet Number GENERAL CS.01 SURVEY A0.10 A0.11 COVER SHEET PROPERTY SURVEY (11 x 17) PLOT PLAN (11 x 17) ARCHITECTURAL SITE PLAN ARCHITECTURAL LDC 25-2 SUB-CHAPTER F A0.20 A0.21 A0.22 A0.23 SITE AND BUILDING AREA CALCULATIONS SIDE SETBACK PLANES SITE PLAN BUILDING TENT ELEVATIONS BUILDING TENT ELEVATIONS EXISTING FLOOR PLAN WITH DEMOLITION PLAN NOTES EXISTING EXTERIOR ELEVATIONS WITH DEMOLITION NOTES ARCHITECTURAL LDC 25-2 SUB-CHAPTER F D0.10 D0.20 ARCHITECTURAL A1.10 A1.20 A1.21 A1.30 A1.31 A1.40 EXISTING BUILDING FLOOR PLAN NEW FIRST FLOOR BUILDING FLOOR PLAN NEW SECOND FLOOR BUILDING FLOOR PLAN EXISTING BUILDING ROOF PLAN NEW ROOF PLAN POWER, DATA AND REFLECTED CEILING PLAN A2.10 A2.11 A2.12 A2.13 A3.10 A3.11 A3.12 EXISTING EXTERIOR ELEVATIONS NEW EXTERIOR ELEVATIONS NEW EXTERIOR ELEVATIONS BUILDING SECTIONS ELEVATIONS INTERIOR ELEVATIONS INTERIOR ELEVATIONS INTERIOR ELEVATIONS X X X X X X X X X X X X X X X X X X X X X X PROJECT DATA VICINITY MAP X X X X X X X X X X X X X X X X X X X X X X X PROJECT LOCATION I E C N E D S E R R O S D N W I H e u n e v A 8 0 9 3 1 5 7 8 7 S A X E T , N I T S U A DESIGN ARCHITECT: 3 6 7 8 7 S A X …

Scraped at: Feb. 24, 2022, 3:51 p.m.
Feb. 28, 2022

B.4.0 - 4203 Speedway original pdf

Thumbnail of the first page of the PDF
Page 1 of 5 pages

HISTORIC LANDMARK COMMISSION APPLICATION FOR A CERTIFICATE OF APPROPRIATENESS FEBRUARY 28, 2022 HR-2022-006140 HYDE PARK HISTORIC DISTRICT 4203 SPEEDWAY B.4 – 1 PROPOSAL PROJECT SPECIFICATIONS Construct a single-story addition to the rear and side of a contributing house, demolishing a non-historic deck and connecting to an existing garage, to be converted to habitable space. Replace the windows, light fixtures, and roof. Repaint the house’s stucco exterior and the existing shed-roofed carport. 1) Replace all windows with wood windows to match existing. 2) Replace the roof in-kind with composition shingles. 3) Construct a single-story addition to the rear and side of the house. The proposed addition is clad in smooth six-inch horizontal fiber cement siding. Its cross-gabled roof features cornice returns to match the original house’s gable end. The proposed addition’s fenestration includes single fixed windows, 1:1 mulled sash windows, 2:2 fixed windows flanking French doors at the rear elevation, and a secondary entry door at the main elevation behind the carport. 4) Convert garage to habitable space, linking it with the addition. The proposed conversions require the existing garage to be re-sided to match the rest of the addition, as well as modification of the building envelope to allow for window installation and roofline changes. 5) Replace entry lights with lighting of similar style and size. ARCHITECTURE DESIGN STANDARDS 4203 Speedway is a one-story Tudor Revival house clad in stucco, with an offset arched entryway, a cross-gabled roof with cornice returns at the gable end, 1:1 and multilight sash and casement windows, and a tapered chimney at the front elevation. The Hyde Park Design Standards are used to evaluate projects within the historic district. The following standards apply to the proposed project: 1. General Standards 1.1: Prevention of Demolition The proposed project partially demolishes an outbuilding not listed as contributing in the district inventory. 1.2: Retention of Historic Style The proposed project appears to respect the historic style of the existing primary building, retaining its character-defining elements and building scale. 1.3: Avoidance of False Historicism The proposed project appears to successfully avoid false historicism from the street-facing elevation, though it does obscure the original function of the outbuilding. 1.4: Appropriate Treatment Options for Contributing or Potentially Contributing Structures The proposed project replaces all windows with wood replicas, including at the main elevation. While the replacements are appropriate, the applicant should consider repairing and retrofitting, rather than replacing, the historic-age windows …

Scraped at: Feb. 24, 2022, 3:55 p.m.
Feb. 28, 2022

B.4.1 - 4203 Speedway - plans original pdf

Thumbnail of the first page of the PDF
Page 1 of 6 pages

1. All trees and natural areas shown on plan to be preserved shall be protected during construction with temporary fencing. 2. Protective fences shall be erected according to City of Austin Standards for Tree Protection. 3. Protective fences shall be installed prior to the start of any site preparation work (clearing, grubbing or grading), and shall be maintained throughout all phases of the construction project. 4. Erosion and sedimentation control barriers shall be installed or maintained in a manner which does not result in soil build-up within tree drip lines. 5. Protective fences shall surround the trees or group of trees, and will be located at the outermost limit of branches (drip line) , for natural areas, protective fences shall follow the Limit of Construction line, in order to prevent the following: A. Soil compaction in the root zone area resulting from vehicular traffic or storage of equipment or materials; B. Root zone disturbances due to grade changes (greater than 6 inches cut or fill), or trenching not reviewed and authorized by the City Aborist; C. Wounds to exposed roots, trunk or limbs by mechanical equipment; D. Other activities detrimental to trees such as chemical storage, cement truck cleaning, and fires. 6. Exceptions to installing fences at tree drip lines may be permitted in the following cases: A. Where there is to be an approved grade change, impermeable paving surface, tree well, or other such site development, erect the fence approximately 2 to 4 feet beyond the area disturbed; B. Where permeable paving is to be installed within a tree's drip line, erect the fence at the outer limits of the permeable paving area (prior to site grading so that this area is graded separately prior to paving installation to minimized root damage); C. Where trees are close to proposed buildings, erect the fence to allow 6 to 10 feet of work space between the fence and the building; D. Where there are severe space constraints due to tract size, or other special requirements, contact the City Arborist at 974-1876 to discuss alternatives. Special Note: For the protection of natural areas, no exceptions to installing fences at the Limit of Construction line will be permitted. 7. Where any of the above exceptions result in a fence being closer than 4 feet to a tree trunk, protect the trunk with strapped-on planking to a height of 8 ft (or to the …

Scraped at: Feb. 24, 2022, 3:55 p.m.
Feb. 28, 2022

B.4.2 - 4203 Speedway - Photos original pdf

Thumbnail of the first page of the PDF
Page 1 of 5 pages

Backup

Scraped at: Feb. 24, 2022, 3:55 p.m.
Feb. 28, 2022

B.5.0 - 1104 E 10th St original pdf

Thumbnail of the first page of the PDF
Page 1 of 5 pages

HISTORIC LANDMARK COMMISSION APPLICATION FOR A CERTIFICATE OF APPROPRIATENESS FEBRUARY 28, 2022 HR-2022-002112 ROBERTSON/STUART & MAIR HISTORIC DISTRICT 1104 E. 10TH STREET B.5 – 1 PROPOSAL Construct an accessory dwelling unit. PROJECT SPECIFICATIONS The proposed ADU is two stories in height, with a covered porch and balcony. It is located behind the contributing main house at 1104 E. 10th Street. It is clad in smooth-finish horizontal fiber cement siding and board-and-batten siding. Fenestration includes mulled and single 1:1 windows, fixed two-panel windows, sliders, and glazed metal entry doors. The proposed plan is canted so that the front-facing balcony and porch are directly behind the main house. A spiral staircase allows access to the second floor. DESIGN STANDARDS 1.4. New Construction The Robertson/Stuart & Mair Design Standards are used to evaluate projects within the historic district. The following standards apply to the proposed project: New construction shall have the same street-front orientation and distance from adjacent buildings as the contributing buildings in the same block. The proposed ADU is oriented toward the south, as is the main house. Setbacks for new construction shall be consistent with setbacks of the district’s contributing buildings by taking the average of the existing setbacks of contributing buildings on the same block face, or by aligning with the setback of one adjacent contributing building; this may allow setbacks that are shallower than the base zoning. The proposed building is located at the rear of the lot. Design new buildings so that they are compatible with and differentiated from historic buildings in the district. If designing an addition in a contemporary style, reflect the scale, massing, and/or materials of the historic building; if designing an addition in a style that reflects a style borrowed from surrounding historic buildings, differentiate the scale, massing, and/or materials. The proposed ADU is differentiated from the main house by its two-story height, irregular shape, irregular shed roof, and modern fenestration and cladding materials. While the exterior cladding and fenestration is mostly compatible, the building’s projecting eave at the main elevation, the spiral staircase, and the shed roofline are less compatible. New construction should have floor-to-floor heights and roof heights that are the same or similar to those on contributing buildings throughout the district. The proposed ADU features similar floor-to-floor heights as the contributing house. Select materials for new construction that are the same as or similar to those found on contributing buildings …

Scraped at: Feb. 24, 2022, 3:56 p.m.
Feb. 28, 2022

B.5.1 - 1104 E 10th St - Plans and photos original pdf

Thumbnail of the first page of the PDF
Page 1 of 15 pages

SITE INFORMATION 1104 E. 10th Street, Austin, TX 78702 SITE ADDRESS: LEGAL DESCRIPTION: West 53' of Lot #10, Block 7, Division B, Geo. L. Robertson Subdivision, A subdivision is Travis County Texas, Recorded in Vol. 1, Page 4. LAND STATUS DETERMINATION: C8I-2011-0149 ZONING: NEIGHBORHOOD: Central East Austin, Subdistrict 1 LAND USE: Single-Family Residence PROPOSED LAND USE: Two-Family Residence Scope Of Work: Construction of a 1 bedroom, 1 bathroom, second floor Accessory Dwelling Unit on top of an Accessory Structure of 1 bathroom and studio. SF-3-NP SITE AREA: 7,457 s.f. NOTE: Areas are measured to the outside of finished surface per C.O.A. Requirements for Building Coverage and FAR. GFA EXISTING HOUSE: 2,115 s.f. Front Covered Porch: Back Covered Porch: Uncovered Deck: Open Stairs: Lower GFA Accessory: Upper GFA ADU: Covered Front Porch: Covered Balcony Above: A/C pads: Storage room stoop: Front Paved Walkway: Total Building Cover: Total Impervious Cover: TOTAL GFA: TOTAL ALLOWED: PROVIDED PARKING: ADU Exempt due to reduced parking requirement. No Changes to primary residence NONE 38 s.f. (calc. at 19 s.f.) 77 s.f. (calc. at 38.5 s.f.) 228 s.f. 130 s.f. 424 s.f. 419 s.f. 82 s.f. 82 s.f. 27 s.f. 9 s.f. 55 s.f. 2,979 s.f. (39.9%) 3,127.5 s.f. (41.9%) 2,958 s.f. (.397) 2,982 s.f. (.4) GENERAL NOTES 1. THESE DRAWINGS ARE BASED UPON THE 2021 INTERNATIONAL BUILDING CODE, AND THE 2021 INTERNATIONAL RESIDENTIAL CODE. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR MEETING ALL REQUIREMENTS OF THIS CODE. THE GENERAL CONTRACTOR SHALL CONTACT THE ARCHITECT IMMEDIATELY WITH ANY DISCREPANCIES BETWEEN CONSTRUCTION DOCUMENTS AND CODE REQUIREMENTS OR DRAWINGS AND MANUFACTURERS' INSTALLATION REQUIREMENTS FOR CLARIFICATION. THESE DRAWINGS MAY NOT INDICATE OR DESCRIBE ALL THE WORK REQUIRED FOR FULL COMPLETION OF THE CONTRACT DOCUMENTS. THE ARCHITECT IS NOT RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES RELATED TO THE PROJECT'S CONSTRUCTION. 2. THE GENERAL CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR CONSTRUCTION SITE SAFETY. THESE DRAWINGS DO NOT INDICATE THE NECESSARY ELEMENTS FOR CONSTRUCTION SAFETY. 3. ALL VERTICAL DIMENSIONS INDICATED ON EXTERIOR ELEVATIONS, BUILDING SECTIONS, DETAILS AND INTERIOR ELEVATIONS ARE NOMINAL. ALL PLAN DIMENSIONS INDICATE EITHER FACE OF FRAMING, FACE OF MASONRY OR CENTERLINE OF ROUGH OPENING UNLESS NOTED OTHERWISE. DO NOT SCALE MEASUREMENTS FROM DRAWINGS. NOTIFY ARCHITECT WITH ANY DIMENSIONAL QUESTIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO COMMENCING WITH THE WORK 4. COORDINATE LOCATION, SIZE AND CONFIGURATION OF PLUMBING VENTING AT ROOF WITH PLUMBING CONTRACTOR. 5. VERIFY AND PROVIDE …

Scraped at: Feb. 24, 2022, 3:56 p.m.
Feb. 28, 2022

B.6.0 - 4300 Speedway original pdf

Thumbnail of the first page of the PDF
Page 1 of 3 pages

HISTORIC LANDMARK COMMISSION PERMITS IN NATIONAL REGISTER HISTORIC DISTRICTS FEBRUARY 28, 2022 HR-2022-009524 HYDE PARK HISTORIC DISTRICT 4300 SPEEDWAY B.6 – 1 PROPOSAL PROJECT SPECIFICATIONS Renovate ca. 1967 former post office to become a shell structure for multiple tenants, with exterior alterations including new entrances, canopies, parapet, and an addition consisting of enclosure of a loading dock. 1) Remove clear anodized aluminum storefront and windows, including limestone trim, on the main (east) elevation. 2) Install new paired storefront doors at three recessed entrances on the east elevation. Install new single and paired storefront doors on the north elevation. Install new divided-light storefront windows. Doors and windows will have black anodized aluminum frames. 3) Construct an addition within the footprint of the loading dock on the south elevation. Brick will match the existing building. Paired doors and divided-light windows will match those used elsewhere on the building. 4) Install a new roof canopy along the east and south elevations. 5) Reroof the building. Extend the height of the parapet using matching brick. Install new painted metal coping. Remove plywood fascia at the existing north canopy and reclad with metal fascia. ARCHITECTURE DESIGN STANDARDS One-story, flat-roofed brick post office building with Modern stylistic influences. The L-shaped building faces east toward Speedway. At the corner of the ell, the main entrance consists of paired glazed doors with a transom and sidelights within limestone trim. The adjacent wall has a section of coursed ashlar limestone next to a long ribbon window set within a limestone frame. The remaining walls are unadorned brick with limited doors and no windows; the rear wall is built of concrete masonry units. A canopy extends along the north wall, and a loading dock abuts the building to the south. The building at 4300 Speedway is noncontributing to the Hyde Park Historic District, as it was less than 50 years of age at the time of the district’s designation in 2010. While most noncontributing buildings do not require historic review, the Hyde Park Preservation Plan and Design Standards specifically address how this building should be treated. In “The Parts of the Hyde Park Preservation Plan,” Section 1.D.2 states: D. Previous Agreements about Specific Properties in the District 2. For the property located at 4300 Speedway, no shed roofs shall be permitted. Otherwise, the standards established for that property by Ordinance No. 0201131-20 [sic], which created the Hyde Park Neighborhood Conservation …

Scraped at: Feb. 24, 2022, 3:56 p.m.
Feb. 28, 2022

B.6.1 - 4300 Speedway - Plans original pdf

Thumbnail of the first page of the PDF
Page 1 of 8 pages

SOUTH ELEVATION (LOADING DOCK) EAST ELEVATION (STOREFRONT) EAST ELEVATION (WITH NORTH COVERED WALKWAY) EAST DETAIL (STOREFRONT - 2 BRICK TYPES) NORTH DETAIL (COVERED WALKWAY) NORTH DETAIL (COVERED WALKWAY) SOUTH - CONCRETE STAIR AND RAMP BRICK 2 - NORMAN BRICK BRICK 1 - STANDARD BRICK SPEEDWAY E ELEVATION SATELLITE VIEW - SOUTH AND EAST ELEVATIONS (GOOGLE MAPS) VIEW FROM 43RD ST - SOUTH AND EAST ELEVATIONS (GOOGLE MAPS) VIEW FROM SPEEDWAY - SOUTH AND EAST ELEVATIONS (GOOGLE MAPS) VIEW FROM SPEEDWAY - EAST AND NORTH ELEVATIONS (GOOGLE MAPS) COVERED WALKWAY I N O T A V E L E N CLR ANOD. ALUMINUM STOREFRONT & DOORS W/ LIMESTONE TRIM E ELEVATION 4300 SPEEDWAY SINGLE STORY STRUCTURE TO BE RENOVATED 9,842 SF NON-SPRINKLERED W ELEVATION (NO ALTERATION) H T R O N N A L P 1 EXISTING PLAN - PHOTOS KEY SCALE: 1/16" = 1'-0" T E E R T S D R 3 4 I N O T A V E L E W LOADING DOCK I I I I N O S S M R E P N E T T R W T U O H T W D E S U R O D E C U D O R P E R E B T O N Y A M D N A N R A B T H G U O H T F O Y T R E P O R P E H T S I I G N W A R D S H T I M P 8 5 : 7 2 : 2 2 2 0 2 / 1 2 / 1 C L L N R A B T H G U O H T I Y B T C E J O R P G N T C X E R E H T O N A I DESIGN THOUGHTBARN LLC 4805 RED BLUFF RD / STUDIO A AUSTIN TX 78702 O: 512 386 1579 INFO@THOUGHTBARN.COM WWW.THOUGHTBARN.COM THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INTERIM REVIEW UNDER THE AUTHORITY OF LUCY BEGG TX REG ARCH #26395 ON THE DATE SHOWN ON THE DATE STAMP. IT IS NOT TO BE USED FOR CONSTRUCTION OR PERMITTING PURPOSES. PROJECT SPEEDWAY COMMERCIAL 4300 SPEEDWAY AUSTIN, TX 78751 STAGE 75% DESIGN DEVELOPMENT DRAWING EXISTING BUILDING PHOTOS DATE As indicated 01/21/22 PAGE NUMBER G4.00 LEGEND OCCUPANCY GROUP OCCUPANT LOAD PARKING AREA OFF STREET …

Scraped at: Feb. 24, 2022, 3:56 p.m.
Feb. 28, 2022

B.6.a - 4300 Speedway - public comment original pdf

Thumbnail of the first page of the PDF
Page 1 of 1 page

Backup

Scraped at: Feb. 24, 2022, 3:57 p.m.
Feb. 28, 2022

B.7.1 - 1502 W 9th St - Plans original pdf

Thumbnail of the first page of the PDF
Page 1 of 8 pages

SITE PLAN NOTES 2. 3. 5. 7. 8. 1. REFER TO G1.0 FOR CODE COMPLIANCE. REFER TO G2.0 FOR ADDITIONAL GENERAL NOTES. SITE INFORMATION SHOWN IS BASED FROM SURVEY DATED JUNE 17, 2020 PREPARED BY WATERLOO SURVEYORS. 4. CONTRACTOR SHALL FIELD VERIFY JOB CONDITIONS AND IMMEDIATELY NOTIFY ARCHITECT OF ANY DISCREPANCIES FROM CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY IF ANY DEFECTS IN THE EXISTING CONSTRUCTION ARE UNCOVERED DURING DEMOLITION WORK SO NECESSARY REPAIRS CAN BE MADE. REPORT ANY CONDITIONS THAT MAY DICTATE UNFORESEEN CHANGES IN THE WORK TO BE PROVIDED. 6. DEMOLITION SITE PLAN IS FOR GUIDANCE ONLY. ANY ADDITIONAL DEMOLITION WORK REQUIRED TO FULLY COMPLETE WORK, BUT NOT OTHERWISE SHOWN OR DESCRIBED IN THE DEMOLITION DRAWINGS SHALL BE CONSIDERED PART OF THE CONTRACT. THE INFORMATION SHOWN ON THESE DRAWINGS INDICATING SIZE, TYPE AND LOCATION OF ANY UNDERGROUND, SURFACE AND AERIAL UTILITIES OR OTHER EXISTING FEATURES IS NOT GUARANTEED TO BE EXACT OF COMPLETE. THE CONTRACTOR SHALL CONTACT THE AUSTIN AREA "ONE CALL" SYSTEM (1-800-344-8377) FOR EXISTING UTILITY LOCATIONS AT LEAST 48 HOURS PRIOR TO BEGINNING ANY EXCAVATION. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR FIELD VERIFYING LOCATIONS AND ELEVATIONS OF ALL EXISTING UTILITIES AFFECTED BY THIS PROJECT'S CONSTRUCTION, IN ORDER TO AVOID DAMAGING THOSE UTILITIES, AND SHALL IMMEDIATELY ARRANGE FOR REPAIR AND RESTORATION OF CONTRACTOR-DAMAGED UTILITIES, TO THE SATISFACTION OF THE UTILITY COMPANY, AT THE EXPENSE OF THE CONTRACTOR. 9. WHERE A SEAMLESS PATCH BETWEEN EXISTING AND NEW SURFACES AND/OR ITEMS IS NOT POSSIBLE OR PRACTICAL, REMOVE EXISTING SURFACE AND/OR ITEM BACK TO NEAREST JOINT AND REPLACE WITH NEW TO MATCH. 10. ALL HAULING AND DISPOSAL OF DEMOLISHED ITEMS SHALL BE PROVIDED BY CONTRACTOR. TREE LIST 0 0 . 4 1 1 0 0 . 3 1 1 ) ' 0 0 . 0 6 E " 0 0 0 0 ° 0 6 ' S ( ' 5 0 . 0 6 W ' " 3 1 4 1 ° 0 6 S Y E L L A ) W O R T F 0 1 ( 0 0 . 4 1 1 LEGEND AND SCALE // // // // // EXISTING FENCE LINE OH EXISTING OVERHEAD LINE EXISTING PUBLIC UTILITY EASEMENT EXISTING TOPOGRAPHY LINE EXISTING ELEMENT TO BE REMOVED PROPERTY LINE SET BACK LINE ADJACENT PROPERTY LINE 8' 4' 0' 10' 20' FULL SIZE SCALE : 1" = 10'-0" OR 1:120 (HALF SIZE SCALE: …

Scraped at: Feb. 24, 2022, 3:57 p.m.
Feb. 28, 2022

B.8.0 - 3312 Duval St original pdf

Thumbnail of the first page of the PDF
Page 1 of 5 pages

HISTORIC LANDMARK COMMISSION APPLICATION FOR A CERTIFICATE OF APPROPRIATENESS FEBRUARY 28, 2022 C14H-2006-0031; HR-2022-015467 STANLEY AND EMILY FINCH HOUSE 3312 DUVAL STREET B.8 – 1 PROPOSAL Remodel house and enlarge kitchen. PROJECT SPECIFICATIONS 1) Rebuilding of the one-story connector between the original historic home (ca. 1928) and an adjacent addition (ca. 2003). Recladding of the hyphen’s wall and roof with standing-seam zinc. Removal of Palladian window at the hyphen and entry door at the addition; replacement with a new divided-light steel door with an awning at the hyphen and a window at the addition. 2) Addition of a third window to an existing pair of mulled windows on the north elevation. 3) Removal of the side entry door and gabled hood on the north elevation. 4) Enlargement of the kitchen to the south, involving removal of a portion of the rear (west) elevation. The addition will have steel windows and zinc cladding. ARCHITECTURE Two-story Colonial Revival house with a side-gabled roof, wood siding, and multi-light double-hung wood windows. The house is on a corner lot and is visible from both Duval and 34th streets. Elements on the 34th St. (north) elevation proposed for modification include paired 6:6 light windows and a small gabled roof with an arched underside and decorative brackets that shelters a multi-light door. The house became a City of Austin Landmark in 2006, after the addition had been constructed. The Recorded Texas Historic Landmark file from 1999 includes photographs of all sides of the house prior to the addition’s construction.1 DESIGN STANDARDS The City of Austin’s Historic Design Standards (March 2021) are based on the Secretary of the Interior’s Standards for Rehabilitation and are used to evaluate projects at historic landmarks. The following standards apply to the proposed project: Repair and alterations 4. Exterior walls and trim Standard 4.2 indicates that, when patching is required, new siding should have a matching profile. Elevation drawings indicate limited replacement of siding to match existing only in the areas to be modified by proposed work. The project meets this standard. 5. Windows, doors, and screens Standard 5.13 establishes requirements for historic landmarks. It states that window and door openings should not be enlarged, moved, or enclosed except as required by an addition. On the west elevation, a limited area of wall including two windows will be removed to accommodate the addition. These are not significant elements and are on the …

Scraped at: Feb. 24, 2022, 3:58 p.m.
Feb. 28, 2022

B.8.1 - 3312 Duval St - Plans original pdf

Thumbnail of the first page of the PDF
Page 1 of 6 pages

600' 599' 598' 597' 596' 595' 594' E 34th St PP PP 601' 602' WV W WV 4 5 CO CO CO G 603' E 6 " 0 - ' 5 1 k c a b t e s t e e r t s e d i s SITE PLAN NOTES 1 2 3 DI 10' - 0" rear setback 25' - 0" front yard setback Section A high point: 604' - 0" Section A high point: 603' - 8 7/16" Section B high point: 601' - 11 1/4" Section A high point: 599' - 6 13/16" E " 0 - ' 5 d r a y e d i s k c a b t e s PP N 1 Site Plan 1/8" = 1'-0" KEYNOTES 1 Critical Root Zone (CRZ) 2 1/2 CRZ 3 1/4 CRZ 4 Property line 5 Limits of work 6 New addition footprint contained within this area; does not impact CRZ of adjacent tree WV WV FH WW PP t S l a v u D IMPERVIOUS COVER AND BUILDING AREA Site Area Allowable Impervious Area (45%) Allowable Floor-to-Area Ratio (40%) Proposed Impervious Cover Area: Main House Building Garage and Pool House Building Driveway Patio and Pool Coping Walkways Proposed Floor-to-Area Ratio (F.A.R.): First Floor Main Building Second Floor Main Building Basement Attic First Floor Garage Building Second Floor Garage Building 16,952 SF 7,628 SF 6,781 SF 1,901 SF 957 SF 1,507 SF 2,005 SF 758 SF 1,901 SF 1,686 SF 388 SF 510 SF 957 SF 575 SF Total Impervious Cover: 7,128 SF (42.0%) Total F.A.R.: 6,017 SF (35.5%) LEGEND PROGRESS PRINT NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION Copyright: These drawings are property of the architect and may not be reproduced, distributed, published, or used in any way without written consent of the architect. L E D O M E R N E H C T I K t e e r t S l a v u D 2 1 3 3 5 0 7 8 7 s a x e T , n i t s u A Historic Review Package February 2, 2022 Drawn by: CG, EK Checked by: CS Revisions: Site Plan G1.10 9 3 4 Limits of work 7 3 6 11 13 12 10 14 3 1 2 9 15 3 5 Existing Den Existing Outdoor Patio 8 Existing Kitchen Existing Dining Room N 1 …

Scraped at: Feb. 24, 2022, 3:58 p.m.
Feb. 28, 2022

B.8.2 - 3312 Duval St - Rendering original pdf

Thumbnail of the first page of the PDF
Page 1 of 1 page

Existing 34th Street frontage (above) Proposed 34th Street frontage (below) PROGRESS PRINT NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION Copyright: These drawings are property of the architect and may not be reproduced, distributed, published, or used in any way without written consent of the architect. L E D O M E R N E H C T I K t e e r t S l a v u D 2 1 3 3 5 0 7 8 7 s a x e T , n i t s u A Historic Review Package February 2, 2022 Drawn by: CG, EK Checked by: CS Revisions: Existing and Proposed Views A5.01 Existing 34th Street frontage (above)Proposed 34th Street frontage (below)

Scraped at: Feb. 24, 2022, 3:58 p.m.
Feb. 28, 2022

B.8.3 - 3312 Duval St - Program diagrams original pdf

Thumbnail of the first page of the PDF
Page 1 of 2 pages

9 3 4 Limits of work 7 3 6 11 13 12 10 14 3 1 2 9 15 3 5 Existing Den Existing Outdoor Patio 8 Existing Kitchen Existing Dining Room N 1 Level 1 - Demo Plan 3/8" = 1'-0" KEYNOTES 1 Demo brick patio and fountain to prepare for new 2 Remove hose and spigot and move to new location; foundation ref. plumbing to be demolished 3 Existing wall, including any windows and doors within, 4 Existing wall finishes to be demolished; utilize existing framing for new construction 5 Keep existing wall and door and tie in with new construction 6 Demo all kitchen millwork, finishes, appliances, and coordinate electrical with new construction 7 Existing windows to remain; coordinate extent of demo to allow for new window at edge of existing 8 Existing millwork to remain; coordinate extent of wall demolition accordingly 9 Existing awning to be demolished 9 Existing eyebrow to be demolished 10 Existing planter to be demolished 11 Existing mechanical chase to remain 12 Plug and seal existing electrical in chase wall, to be covered in new construction 13 Remove refrigerator; store for reuse 14 Remove wine cooler and associated doors/trim; store for reuse 15 Existing door to be demolished 15 Existing front door DEMO PLAN NOTES 1. 2. 3. 4. 5. 6. Refer to architectural drawings prior to demolition to understand the scope of work. Re: sheet A1.01 for the architectural floor plan. All existing electrical, plumbing and mechanical systems to be removed. Contractor to take care removing doors and systems in aluminum storefront systems. All existing glass panel windows to be removed and replaced. Remove all ceiling finishes and insulation. Expose all structural framing and ceilings. 15 LEGEND PROGRESS PRINT NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION Copyright: These drawings are property of the architect and may not be reproduced, distributed, published, or used in any way without written consent of the architect. L E D O M E R N E H C T I K t e e r t S l a v u D 2 1 3 3 5 0 7 8 7 s a x e T , n i t s u A Historic Review Package February 2, 2022 Drawn by: CG, EK Checked by: CS Revisions: Demolition Plan D1.01 11 " 5 7 . Up 101b 9 DS 10 11 Refrigerator/Freezer Pantry Baking Area 1 …

Scraped at: Feb. 24, 2022, 3:58 p.m.
Feb. 28, 2022

C.1.0 - 804 Rutherford Pl original pdf

Thumbnail of the first page of the PDF
Page 1 of 14 pages

HISTORIC LANDMARK COMMISSION PERMITS IN NATIONAL REGISTER HISTORIC DISTRICTS FEBRUARY 28, 2022 HR-2021-205974 TRAVIS HEIGHTS-FAIRVIEW PARK 804 RUTHERFORD PLACE C.1– 1 PROPOSAL PROJECT SPECIFICATIONS Demolish a contributing duplex and detached carport. Construct a new single-family residence with pool and two-story cabana. 1) Total demolition of existing contributing duplex and detached carport. 2) Construction of new single-family residence with pool and two-story cabana. The proposed primary building is two stories with a habitable attic and roof deck. It features an irregular flat, gabled, and shed roofline; fixed-pane and casement full-light fenestration in irregular pattern; stucco cladding; and a front-facing garage. The pool cabana is two stories in height with stucco cladding, a gabled roofline, and fixed-pane windows on two elevations; the west and south secondary elevations are windowless. ARCHITECTURE The 2020 Travis Heights-Fairview Park National Register Nomination lists 804 Rutherford Place as the only example of a representative domestic property constructed with a “mixed” architectural style. This unique eclecticism includes Mission, Tudor Revival, and Swiss influences. The nomination’s description is as follows: The small apartment building at 804 Rutherford Place is a good example of an eclectic, mixed design that draws from three styles, in this case Mission Revival, Tudor Revival, and Swiss. The building is two stories in height, with buff- and tan-colored brick walls and a flat roof. The front elevation has a symmetrical arrangement, with a one-story, partial-width entrance volume extending from the rectangular main building volume. The projecting entrance has Tudor Revival details including an arched entrance door, arched hood molding over the door, narrow windows with decorative shutters, and flared wrought iron stair railings. The main two-story volume has little decoration. It has single 1/1 windows on the first floor and two sets of paired 1/1 windows on the second floor. Its modest Mission Revival details are limited to a narrow, divided light, arched window in the center of the upper floor, and a stepped parapet. The Swiss detailing includes the scalloped bargeboard. All window openings have brick sills, and the parapet coping is brick.1 Notably, the building at 806 Rutherford Place is constructed with a similar plan, form, and fenestration pattern, though 806 Rutherford shows only Mission influences. 806 Rutherford was constructed in 1925 by the Austin Real Estate Abstract Company. 803 E. Riverside Drive, constructed by the same company in 1925 and displaying similar Mission styling to 806 Rutherford, is located immediately behind 804 …

Scraped at: Feb. 24, 2022, 3:58 p.m.