Zoning and Platting CommissionSept. 6, 2022

07 C8-2022-0221 - River Park South; District 3.pdf — original pdf

Backup
Thumbnail of the first page of the PDF
Page 1 of 49 pages

SUBDIVISION REVIEW SHEET CASE NO.: C8-2022-0221 COMMISSION DATE: September 6, 2022 SUBDIVISION NAME: River Park South Preliminary Plan ADDRESS: 4799 E Riverside Drive APPLICANT: Michael Piano (Presidium) AGENT: Julia Mrnack (Garza EMC) • Corridor Mixed Use • Neighborhood Mixed Use • Urban Residential NEIGHBORHOOD PLAN: Pleasant Valley ZONING: ERC (East Riverside Corridor) with the following subdistricts: AREA: 67.7 acres COUNTY: Travis LOTS: 24 DISTRICT: 3 WATERSHED: Country Club West JURISDICTION: Full Purpose SIDEWALKS: Sidewalks will be constructed along Wickersham Lane, Crossing Place, S Pleasant Valley Road and Elmont Drive. VARIANCE: none DEPARTMENT COMMENTS: The request is for the approval of the River Park South preliminary plan, comprised of 24 lots on 67.7 acres. The preliminary plan does not comply with the criteria for approval in LDC 25-4-57 and staff recommends disapproval for the reasons listed in the attached comment report. An application that has been disapproved with reasons may be updated to address those reasons until the application expires. If the applicant submits an update to address the reasons for disapproval, that update will be presented to the Land Use Commission within fifteen days of submittal. STAFF RECOMMENDATION: Staff recommends disapproval of the preliminary plan for the reasons listed in the comment report dated September 1, 2022, and attached as Exhibit C. CASE MANAGER: Steve Hopkins PHONE: 512-974-3175 E-mail: steve.hopkins@austintexas.gov ATTACHMENTS Exhibit A: Vicinity map Exhibit B: Proposed preliminary plan Exhibit C: Comment report dated September 1, 2022 VICINITY MAP MAPSCO GRID #'S 615U, 615V, 615Y, 615Z COA GRID : K-19 N.T.S. OWNERS: NRE EDGE, LLC 3100 MCKINNON STREET, SUITE 250 DALLAS, TEXAS 75201-1112 BP RIVERSIDE WEST, LLC 1601 RIO GRANDE STREET, SUITE 300 AUSTIN, TEXAS 78701 EAST RIVERSIDE RETAIL, LLC 3100 MCKINNON STREET, SUITE 250 DALLAS, TEXAS 75201-1112 NRE ZONE, LLC 3100 MCKINNON STREET, SUITE 250 DALLAS, TEXAS 75201 ENGINEER: GarzaEMC, LLC. 7708 RIALTO BLVD, SUITE 125 AUSTIN, TEXAS 78735 (512) 298-3284 SURVEYOR: CEC SURVEYING 3711 S. MOPAC EXPY BLDG 1, SUITE 550 AUSTIN, TEXAS 78746 CONTACT: SYD XINOS (512) 298-3284 NOTE: CEF NOTE: ALL RESPONSIBILITY FOR THE ACCURACY OF THESE PLANS REMAINS WITH THE ENGINEER WHO PREPARED THEM. IN REVIEWING THESE PLANS, THE CITY MUST RELY ON THE ADEQUACY OF THE WORK OF THE DESIGN ENGINEER. THE PRESENCE OF A CRITICAL ENVIRONMENTAL FEATURES ON OR NEAR A PROPERTY MAY AFFECT DEVELOPMENT. ALL ACTIVITIES WITHIN THE CEF BUFFER MUST COMPLY WITH THE CITY OF AUSTIN CODE AND CRITERIA. THE NATURAL VEGETATIVE COVER MUST BE RETAINED TO THE MAXIMUM EXTENT PRACTICABLE; CONSTRUCTION IS PROHIBITED; AND WASTEWATER DISPOSAL OR IRRIGATION IS PROHIBITED. WATERSHED STATUS: NO PORTIONS OF THE SITE LIE WITHIN EDWARDS AQUIFER RECHARGE ZONE. THIS SITE LIES WITHIN A SUBURBAN WATERSHED KNOWN AS THE COUNTRY CLUB WEST WATERSHED. FLOODPLAIN INFORMATION: PORTIONS OF THIS SITE ARE LOCATED IN ZONE AE AS SHOWN BY GRAPHIC SCALING FROM THE FLOOD INSURANCE RATE MAP PANEL NO. 48453C0605J FOR TRAVIS COUNTY, TEXAS, DATED JANUARY 6, 2016. ZONE AE IS CONTAINED WITHIN THE DRAINAGE EASEMENTS AS SHOWN IN THIS PLAN. DRAINAGE EASEMENTS TO BE DEDICATED DURING FINAL PLATTING. VARIANCE NOTE: AN ADMINISTRATIVE VARIANCE HAS BEEN GRANTED PER LDC 25-8-42(B)(3) TO ALLOW ELMONT DRIVE TO CROSS THE CRITICAL WATER QUALITY ZONE. SITE PRELIMNARY PLAN FOR SHT. NO. TITLE SHEET INDEX RIVER PARK - SOUTH PRELIMINARY PLAN NO. DESCRIPTION REVISE (R) ADD (A) VOID (V) SHEET NO.'S TOTAL # SHEETS IN PLAN SET NET CHANGE IMP. COVER (sq. ft.) TOTAL SITE IMP. COVER (sq. ft.) [%] CITY OF AUSTIN APPROVAL/DATE DATE IMAGED PERMIT NUMBER : C8-2020-0004 ORIGINAL SUBMITTAL DATE : NOVEMBER 4, 2020 SUBMITTED BY : JULIA L. MRNAK, P.E. GarzaEMC, LLC. 7708 RIALTO BLVD, SUITE 125 AUSTIN, TEXAS 78735 (512) 298-3284 DATE PLAN SUBMITTALS: NO. DATE COMMENTS RELATED CASES: C8-2020-0004PA TOTAL ACREAGE: 67.71 AC NUMBER OF LOTS: 24 PRELIMINARY SUBDIVISION APPROVAL SHEET 01 OF 10. FILE NUMBER: C8-2020-0004 APPLICATION DATE: EXPIRATION DATE (LCD 25-4-62): CASE MANAGER: APPROVED BY LAND USE COMMISSION ON ____________ _______________________________________________ STEVE HOPKINS, FOR: DENISE LUCAS DIRECTOR, DEVELOPMENT SERVICES DEPARTMENT SHEET 01 OF 10 FINAL PLATS MUST BE RECORDED BY THE EXPIRATION DATE. SUBSEQUENT SITE PLANS WHICH DO NOT COMPLY WITH THE CODE CURRENT AT THE TIME OF FILING, AND REQUIRE BUILDING PERMITS OR A NOTICE OF CONSTRUCTION (IF A BUILDING PERMIT IS NOT REQUIRED) MUST ALSO BE APPROVED PRIOR TO THE PROJECT EXPIRATION DATE. C8-2020-0004 7708 Rialto Blvd., Suite 125 Austin, Texas 78735 Tel. (512) 298-3284 Fax (512) 298-2592 TBPE # F-14629 GarzaEMC, LLC © Copyright 2022 I, JULIA L. MRNAK, P.E., CERTIFY THAT THESE ENGINEERING DOCUMENTS ARE COMPLETE, ACCURATE AND ADEQUATE FOR THE INTENDED PURPOSES, INCLUDING CONSTRUCTION, BUT ARE NOT AUTHORIZED FOR CONSTRUCTION PRIOR TO FORMAL CITY APPROVAL. NOTE: ASSIGNED CITY ADDRESS NUMBERS SHALL BE PERMANENTLY AFFIXED TO ALL STRUCTURES IN SUCH POSITIONS AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET. I N A L P Y R A N M I L E R P H T U O S - K R A P R E V R I M P 8 5 : 5 2 2 , 1 1 l u J n o n a m y r r e m a y b d e i f i d o m g w d . R V C - 2 0 0 0 0 - 8 3 8 3 1 1 \ h t u o S l - n a P y r a n m i i l \ e r P D A C - 0 0 \ l i i v C \ 2 0 0 0 0 - 8 3 8 3 1 1 \ : V 07/11/2022C8-2022-0221C8-2022-0221C8-2022-0221C8-2022-0221 VICINITY MAP MAPSCO GRID #'S 615U, 615V, 615Y, 615Z COA GRID : K-19 N.T.S. OWNERS: NRE EDGE, LLC 3100 MCKINNON STREET, SUITE 250 DALLAS, TEXAS 75201-1112 BP RIVERSIDE WEST, LLC 1601 RIO GRANDE STREET, SUITE 300 AUSTIN, TEXAS 78701 EAST RIVERSIDE RETAIL, LLC 3100 MCKINNON STREET, SUITE 250 DALLAS, TEXAS 75201-1112 NRE ZONE, LLC 3100 MCKINNON STREET, SUITE 250 DALLAS, TEXAS 75201 ENGINEER: GarzaEMC, LLC. 7708 RIALTO BLVD, SUITE 125 AUSTIN, TEXAS 78735 (512) 298-3284 SURVEYOR: CEC SURVEYING 3711 S. MOPAC EXPY BLDG 1, SUITE 550 AUSTIN, TEXAS 78746 CONTACT: SYD XINOS (512) 298-3284 NOTE: CEF NOTE: ALL RESPONSIBILITY FOR THE ACCURACY OF THESE PLANS REMAINS WITH THE ENGINEER WHO PREPARED THEM. IN REVIEWING THESE PLANS, THE CITY MUST RELY ON THE ADEQUACY OF THE WORK OF THE DESIGN ENGINEER. THE PRESENCE OF A CRITICAL ENVIRONMENTAL FEATURES ON OR NEAR A PROPERTY MAY AFFECT DEVELOPMENT. ALL ACTIVITIES WITHIN THE CEF BUFFER MUST COMPLY WITH THE CITY OF AUSTIN CODE AND CRITERIA. THE NATURAL VEGETATIVE COVER MUST BE RETAINED TO THE MAXIMUM EXTENT PRACTICABLE; CONSTRUCTION IS PROHIBITED; AND WASTEWATER DISPOSAL OR IRRIGATION IS PROHIBITED. WATERSHED STATUS: NO PORTIONS OF THE SITE LIE WITHIN EDWARDS AQUIFER RECHARGE ZONE. THIS SITE LIES WITHIN A SUBURBAN WATERSHED KNOWN AS THE COUNTRY CLUB WEST WATERSHED. FLOODPLAIN INFORMATION: PORTIONS OF THIS SITE ARE LOCATED IN ZONE AE AS SHOWN BY GRAPHIC SCALING FROM THE FLOOD INSURANCE RATE MAP PANEL NO. 48453C0605J FOR TRAVIS COUNTY, TEXAS, DATED JANUARY 6, 2016. ZONE AE IS CONTAINED WITHIN THE DRAINAGE EASEMENTS AS SHOWN IN THIS PLAN. DRAINAGE EASEMENTS TO BE DEDICATED DURING FINAL PLATTING. VARIANCE NOTE: AN ADMINISTRATIVE VARIANCE HAS BEEN GRANTED PER LDC 25-8-42(B)(3) TO ALLOW ELMONT DRIVE TO CROSS THE CRITICAL WATER QUALITY ZONE. SITE PRELIMNARY PLAN FOR SHT. NO. TITLE SHEET INDEX RIVER PARK - SOUTH PRELIMINARY PLAN NO. DESCRIPTION REVISE (R) ADD (A) VOID (V) SHEET NO.'S TOTAL # SHEETS IN PLAN SET NET CHANGE IMP. COVER (sq. ft.) TOTAL SITE IMP. COVER (sq. ft.) [%] CITY OF AUSTIN APPROVAL/DATE DATE IMAGED PERMIT NUMBER : C8-2020-0004 ORIGINAL SUBMITTAL DATE : NOVEMBER 4, 2020 SUBMITTED BY : JULIA L. MRNAK, P.E. GarzaEMC, LLC. 7708 RIALTO BLVD, SUITE 125 AUSTIN, TEXAS 78735 (512) 298-3284 DATE PLAN SUBMITTALS: NO. DATE COMMENTS RELATED CASES: C8-2020-0004PA TOTAL ACREAGE: 67.71 AC NUMBER OF LOTS: 24 PRELIMINARY SUBDIVISION APPROVAL SHEET 01 OF 10. FILE NUMBER: C8-2020-0004 APPLICATION DATE: EXPIRATION DATE (LCD 25-4-62): CASE MANAGER: APPROVED BY LAND USE COMMISSION ON ____________ _______________________________________________ STEVE HOPKINS, FOR: DENISE LUCAS DIRECTOR, DEVELOPMENT SERVICES DEPARTMENT SHEET 01 OF 10 FINAL PLATS MUST BE RECORDED BY THE EXPIRATION DATE. SUBSEQUENT SITE PLANS WHICH DO NOT COMPLY WITH THE CODE CURRENT AT THE TIME OF FILING, AND REQUIRE BUILDING PERMITS OR A NOTICE OF CONSTRUCTION (IF A BUILDING PERMIT IS NOT REQUIRED) MUST ALSO BE APPROVED PRIOR TO THE PROJECT EXPIRATION DATE. C8-2020-0004 7708 Rialto Blvd., Suite 125 Austin, Texas 78735 Tel. (512) 298-3284 Fax (512) 298-2592 TBPE # F-14629 GarzaEMC, LLC © Copyright 2022 I, JULIA L. MRNAK, P.E., CERTIFY THAT THESE ENGINEERING DOCUMENTS ARE COMPLETE, ACCURATE AND ADEQUATE FOR THE INTENDED PURPOSES, INCLUDING CONSTRUCTION, BUT ARE NOT AUTHORIZED FOR CONSTRUCTION PRIOR TO FORMAL CITY APPROVAL. NOTE: ASSIGNED CITY ADDRESS NUMBERS SHALL BE PERMANENTLY AFFIXED TO ALL STRUCTURES IN SUCH POSITIONS AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET. I N A L P Y R A N M I L E R P H T U O S - K R A P R E V R I M P 8 5 : 5 2 2 , 1 1 l u J n o n a m y r r e m a y b d e i f i d o m g w d . R V C - 2 0 0 0 0 - 8 3 8 3 1 1 \ h t u o S l - n a P y r a n m i i l \ e r P D A C - 0 0 \ l i i v C \ 2 0 0 0 0 - 8 3 8 3 1 1 \ : V 07/11/2022C8-2022-0221C8-2022-0221C8-2022-0221C8-2022-0221 15. T 2 9 5 2 - 8 9 2 ) 2 1 5 ( x a F 4 8 2 3 - 8 9 2 ) 2 1 5 ( . l e T 2 2 0 2 t h g i r y p o C © C L L , C M E a z r a G 9 2 6 4 1 - F # E P B T 5 2 1 e t i u S l , . d v B o t l a R 8 0 7 7 i 5 3 7 8 7 s a x e T , n i t s u A I N O S V E R I . O N E T A D S E T O N L A R E N E G I N A L P Y R A N M L E R P H T U O S I - K R A P R E V R I S A X E T , Y T N U O C S V A R T I , I N T S U A F O Y T C I P U O R G M U D S E R P I I PRELIMINARY SUBDIVISION APPROVAL SHEET 02 OF 10. FILE NUMBER: C8-2020-0004 APPLICATION DATE: EXPIRATION DATE (LCD 25-4-62): CASE MANAGER: APPROVED BY LAND USE COMMISSION ON ____________ _______________________________________________ STEVE HOPKINS, FOR: DENISE LUCAS DIRECTOR, DEVELOPMENT SERVICES DEPARTMENT FINAL PLATS MUST BE RECORDED BY THE EXPIRATION DATE. SUBSEQUENT SITE PLANS WHICH DO NOT COMPLY WITH THE CODE CURRENT AT THE TIME OF FILING, AND REQUIRE BUILDING PERMITS OR A NOTICE OF CONSTRUCTION (IF A BUILDING PERMIT IS NOT REQUIRED) MUST ALSO BE APPROVED PRIOR TO THE PROJECT EXPIRATION DATE. 2 0 0 0 0 - 8 3 8 3 1 1 : . O N T C E J O R P : Y B D E N G S E D I : Y B N W A R D : C Q / A Q SHEET 02 OF 10 C8-2020-0004 M A 1 3 1 1 2 2 : , 2 g u A n o l a e r r a l l i v j y b d e i f i . d o m g w d S E T O N - 2 0 0 0 0 - 8 3 8 3 1 1 \ h t u o S l - n a P y r a n m i i l \ e r P D A C - 0 0 \ l i i v C \ 2 0 0 0 0 - 8 3 8 3 1 1 \ : V 01/29/202108/02/2022C8-2022-0221 BLOCK C LOT 1 0.35 AC ELMONT DRIVE (70' PUBLIC R.O.W.) LOT 1 2.41 AC LOT 2 3.31 AC D A O R Y E L L A V T N A S A E L P S ) . . . W O R C I L B U P E D W ' 0 2 1 ( I LOT 3 3.79 AC LOT 4 3.40 AC BLOCK A LOT 5 1.19 AC LOT 7 2.57 AC LOT 6 1.43 AC LOT 8 2.56 AC LOT 1 3.58 AC BLOCK B LOT 2 6.03 AC LOT 5 6.63 AC LOT 3 2.27 AC ) . E N A L M A H S R E K C I W W . O . R C I L B U P H T D I W E L B A I R A V ( LOT 4 2.32 AC LOT 1 5.00 AC LOT 5 3.31 AC BLOCK D LOT 9 2.44 AC LOT 10 2.37 AC LOT 11 1.70 AC LOT 12 2.96 AC LOT 3 2.41 AC LOT 4 2.60 AC E C A L P ) . W O . . R C I G N L B U P E D W I ' 0 0 1 ( I S S O R C LOT 13 1.12 AC LOT 2 1.96 AC E R I V E R S I D E D R I V E V A R I E S ) ( R . O . W . LEGEND E C A L P G N S S O R C I ) . . . W O R C I L B U P E D W ' 0 0 1 ( I 2 9 5 2 - 8 9 2 ) 2 1 5 ( x a F 4 8 2 3 - 8 9 2 ) 2 1 5 ( . l e T 2 2 0 2 t h g i r y p o C © C L L , C M E a z r a G 9 2 6 4 1 - F # E P B T 5 2 1 e t i u S l , . d v B o t l a R 8 0 7 7 i 5 3 7 8 7 s a x e T , n i t s u A I N O S V E R I . O N E T A D I I N A L P Y R A N M L E R P L L A R E V O I N A L P Y R A N M L E R P H T U O S I - K R A P R E V R I S A X E T , Y T N U O C S V A R T I , I N T S U A F O Y T C I P U O R G M U D S E R P I I PRELIMINARY SUBDIVISION APPROVAL SHEET 03 OF 10. FILE NUMBER: C8-2020-0004 APPLICATION DATE: EXPIRATION DATE (LCD 25-4-62): CASE MANAGER: APPROVED BY LAND USE COMMISSION ON ____________ _______________________________________________ STEVE HOPKINS, FOR: DENISE LUCAS DIRECTOR, DEVELOPMENT SERVICES DEPARTMENT FINAL PLATS MUST BE RECORDED BY THE EXPIRATION DATE. SUBSEQUENT SITE PLANS WHICH DO NOT COMPLY WITH THE CODE CURRENT AT THE TIME OF FILING, AND REQUIRE BUILDING PERMITS OR A NOTICE OF CONSTRUCTION (IF A BUILDING PERMIT IS NOT REQUIRED) MUST ALSO BE APPROVED PRIOR TO THE PROJECT EXPIRATION DATE. 2 0 0 0 0 - 8 3 8 3 1 1 : . O N T C E J O R P : Y B D E N G S E D I : Y B N W A R D : C Q / A Q SHEET 03 OF 10 C8-2020-0004 M P 6 5 6 2 2 : , 1 1 l u J n o n a m y r r e m a y b d e i f i . I d o m g w d E T S - 2 0 0 0 0 - 8 3 8 3 1 1 \ h t u o S l - n a P y r a n m i i l \ e r P D A C - 0 0 \ l i i v C \ 2 0 0 0 0 - 8 3 8 3 1 1 \ : V 01/29/202107/11/2022C8-2022-0221 BLOCK C LOT 1 0.35 AC LOT 1 3.58 AC BLOCK B ELMONT DRIVE (70' PUBLIC R.O.W.) LOT 1 2.41 AC LOT 2 3.31 AC LOT 3 3.79 AC LOT 4 3.40 AC D A O R Y E L L A V T N A S A E L P S ) . . . W O R C I L B U P E D W ' 0 2 1 ( I BLOCK A LOT 5 1.19 AC LOT 6 1.43 AC LOT 7 2.57 AC LOT 8 2.56 AC (cid:0)/(cid:0)((cid:0)*(cid:0)((cid:0)1(cid:0)' E C A L P G N S S O R C I ) . . . W O R C I L B U P E D W ' 0 0 1 ( I 2 9 5 2 - 8 9 2 ) 2 1 5 ( x a F 4 8 2 3 - 8 9 2 ) 2 1 5 ( . l e T 2 2 0 2 t h g i r y p o C © C L L , C M E a z r a G 9 2 6 4 1 - F # E P B T 5 2 1 e t i u S l , . d v B o t l a R 8 0 7 7 i 5 3 7 8 7 s a x e T , n i t s u A I N O S V E R I . O N E T A D N A L P Y R A N M I L E R P I 2 F O 1 E L A C S 0 0 1 I N A L P Y R A N M L E R P H T U O S I - K R A P R E V R I S A X E T , Y T N U O C S V A R T I , I N T S U A F O Y T C I P U O R G M U D S E R P I I LOT 2 6.03 AC LOT 5 6.63 AC LOT 3 2.27 AC ) . E N A L M A H S R E K C I W W . O . R C I L B U P H T D I W E L B A I R A V ( LOT 4 2.32 AC LOT 1 5.00 AC PRELIMINARY SUBDIVISION APPROVAL SHEET 04 OF 10. FILE NUMBER: C8-2020-0004 APPLICATION DATE: EXPIRATION DATE (LCD 25-4-62): CASE MANAGER: APPROVED BY LAND USE COMMISSION ON ____________ _______________________________________________ STEVE HOPKINS, FOR: DENISE LUCAS DIRECTOR, DEVELOPMENT SERVICES DEPARTMENT FINAL PLATS MUST BE RECORDED BY THE EXPIRATION DATE. SUBSEQUENT SITE PLANS WHICH DO NOT COMPLY WITH THE CODE CURRENT AT THE TIME OF FILING, AND REQUIRE BUILDING PERMITS OR A NOTICE OF CONSTRUCTION (IF A BUILDING PERMIT IS NOT REQUIRED) MUST ALSO BE APPROVED PRIOR TO THE PROJECT EXPIRATION DATE. 2 0 0 0 0 - 8 3 8 3 1 1 : . O N T C E J O R P : Y B D E N G S E D I : Y B N W A R D : C Q / A Q SHEET 04 OF 10 C8-2020-0004 M P 2 5 4 2 2 : , 1 1 l u J n o n a m y r r e m a y b d e i f i d o m g w d . I 1 - E T S - 2 0 0 0 0 - 8 3 8 3 1 1 \ h t u o S l - n a P y r a n m i i l e r p \ D A C - 0 0 \ l i i v C \ 2 0 0 0 0 - 8 3 8 3 1 1 \ : V 01/29/202107/11/2022C8-2022-0221 D A O R Y E L L A V T N A S A E L P S ) . . . W O R C I L B U P E D W ' 0 2 1 ( I BLOCK A LOT 5 1.19 AC LOT 6 1.43 AC LOT 7 2.57 AC LOT 8 2.56 AC LOT 9 2.44 AC LOT 10 2.37 AC LOT 11 1.70 AC LOT 12 2.96 AC LOT 3 2.27 AC ) . E N A L M A H S R E K C I W W . O . R C I L B U P H T D I W E L B A I R A V ( LOT 4 2.32 AC LOT 2 6.03 AC LOT 5 6.63 AC LOT 1 5.00 AC LOT 5 3.31 AC BLOCK D LOT 3 2.41 AC LOT 4 2.60 AC E C A L P ) . W O . . R C I G N L B U P E D W I ' 0 0 1 ( I S S O R C LOT 13 1.12 AC LOT 2 1.96 AC E R I V E R S I D E D R I V E V A R I E S ) ( R . O . W . LEGEND 2 9 5 2 - 8 9 2 ) 2 1 5 ( x a F 4 8 2 3 - 8 9 2 ) 2 1 5 ( . l e T 2 2 0 2 t h g i r y p o C © C L L , C M E a z r a G 9 2 6 4 1 - F # E P B T 5 2 1 e t i u S l , . d v B o t l a R 8 0 7 7 i 5 3 7 8 7 s a x e T , n i t s u A I N O S V E R I . O N E T A D N A L P Y R A N M I L E R P I 2 F O 2 E L A C S 0 0 1 I N A L P Y R A N M L E R P H T U O S I - K R A P R E V R I S A X E T , Y T N U O C S V A R T I , I N T S U A F O Y T C I P U O R G M U D S E R P I I PRELIMINARY SUBDIVISION APPROVAL SHEET 05 OF 10. FILE NUMBER: C8-2020-0004 APPLICATION DATE: EXPIRATION DATE (LCD 25-4-62): CASE MANAGER: APPROVED BY LAND USE COMMISSION ON ____________ _______________________________________________ STEVE HOPKINS, FOR: DENISE LUCAS DIRECTOR, DEVELOPMENT SERVICES DEPARTMENT FINAL PLATS MUST BE RECORDED BY THE EXPIRATION DATE. SUBSEQUENT SITE PLANS WHICH DO NOT COMPLY WITH THE CODE CURRENT AT THE TIME OF FILING, AND REQUIRE BUILDING PERMITS OR A NOTICE OF CONSTRUCTION (IF A BUILDING PERMIT IS NOT REQUIRED) MUST ALSO BE APPROVED PRIOR TO THE PROJECT EXPIRATION DATE. 2 0 0 0 0 - 8 3 8 3 1 1 : . O N T C E J O R P : Y B D E N G S E D I : Y B N W A R D : C Q / A Q SHEET 05 OF 10 C8-2020-0004 M P 9 5 3 2 2 : , 1 1 l u J n o n a m y r r e m a y b d e i f i d o m g w d . I 2 - E T S - 2 0 0 0 0 - 8 3 8 3 1 1 \ h t u o S l - n a P y r a n m i i l e r p \ D A C - 0 0 \ l i i v C \ 2 0 0 0 0 - 8 3 8 3 1 1 \ : V 01/29/202107/11/2022C8-2022-0221 CITY OF AUSTIN –DEVELOPMENT SERVICES DEPARTMENT SUBDIVISION APPLICATION – MASTER COMMENT REPORT CASE NUMBER: UPDATE: CASE MANAGER: C8-2022-0221 U0 Steve HopkinsPHONE #: 512-974-3175 PROJECT NAME: LOCATION: River Park South 4700 E RIVERSIDE DR SUBMITTAL DATE: August 8, 2022 FINAL REPORT DATE: September 1, 2022 STAFF REPORT: This report includes all staff comments received to date concerning your most recent subdivision application submittal. The comments may include requirements, recommendations, or information. The requirements in this report must be addressed by an updated submittal. The subdivision application will be approved when all requirements from each review discipline have been addressed. If you have any questions, concerns or if you require additional information about this report, please contact your case manager at the phone number listed above or by using the contact information listed for each reviewer in this report. Any change to the plan/plat shall not cause noncompliance with any applicable code or criteria. In addition, any change to the plat may trigger new comments. UPDATE DEADLINE INFORMATION (LDC 25-4-56; 25-4-82): All comments must be addressed by filing an updated submittal prior to the update deadline of November 7, 2022. Otherwise, the application will expire. If this date falls on a weekend or City of Austin holiday, the next City of Austin workday will be the deadline. Extension of Review Period, Extension of Update Deadline and Tolling of Application Period do not apply to applications for preliminary plan, plat or subdivision construction plans (LDC 25-1-88; 25-1-89; 25-1- 90). UPDATE SUBMITTAL INSTRUCTIONS (LDC 25-1-83): 1. Applicants must make an appointment with Intake Staff (974-1770) in order to submit an update. 2. Your update must include the following items: a. The revised plat/plan in pdf format b. A letter that addresses each comment in the master comment report 3. Updates must be submitted on an approved submittal date, between the hours of 8:30 am and 4:00 pm. Refer to the submittal calendar for a list of approved submittal dates. REVIEWERS: Planner 1 : Cindy Edmond ATD Engineering : Amber Hutchens Environmental : Mike Mcdougal PARD / Planning & Design : Thomas Rowlinson Drainage Engineering & WQ Review - Don Heisch Flood Plain Review - Kena Pierce Subdivision Review - Steve Hopkins PARD / Planning & Design Review - Thomas Rowlinson - 512-974-9372 PR1: To demonstrate compliance with parkland dedication, City Code 25-1-601 and 602, revise note #20: “The areas available for dedication to the City are shown on this preliminary plan as: […]”. Revise last sentence to “Final limits of parkland dedication will be determined at time of dedication”. PR2: To qualify for the East Riverside Corridor Regulating Plan, Article 6, Section 6.4.2., remove the first sentence of note 21 of the general notes and note 1 on the park exhibit. PR3: To comply with City Code 25-1-602, note on the preliminary plan sheets the location of the parkland as “"Parkland Dedicated to the City of Austin”. In the call-out on the park exhibit, remove reference to “common area, greenspace, greenway, private open space, and creek restoration”. Note only “"Parkland Dedicated to the City of Austin". PR4: To comply with City Code 25-1-602, note that the final credit for parkland will be assigned at the time of dedication. Additional fee in-lieu may be required. Electric Review - Andrea Katz - 512-322-6957 Approved. 911 Addressing Review - Janny Phung - janny.phung@austintexas.gov AD1: This plat review is cleared; however, any changes to street names, street name labels, or street layouts will require a new review. §25-4-155 ATD Engineering Review - Amber Hutchens - 512-974-5646 ATD transportation review fees as adopted by City Council will be added to AMANDA. These fees can be paid online on ABC portal. The incorrect fee was added to this application. Please email Zachary.whitaker@austintexas.gov to have the final plat fee refunded and the preliminary plan fee added. Drainage Engineering Review - Don Heisch – (512) 978-1736 - Don.Heisch@austintexas.gov Release of this application does not constitute a verification of all data, information, and calculations supplied by the applicant. The engineer of record is solely responsible for the completeness, accuracy, and adequacy of his/her submittal, whether or not the application is reviewed for code compliance by city engineers. Provide drainage easement for the conveyance of off-site flows through the property. The drainage easements shall encompass the limits of the 100 year fully developed flow per LDC 25-7-152 and shall meet the minimum widths specified in DCM 1.2.4.G. Verify the floodplain information shown on the Cover Sheet. The flood map appears to be incorrect. Remove General Note 23. The erosion hazard zone analysis shall be completed with the preliminary plan. ATD 1. DE 1. DE 2. DE 3. DE 4. Provide an erosion hazard zone (EHZ) analysis per DCM Appendix E. DE 5. DE 6. DE 7. DE 8. DE 9. DE 10. DE 11. DE 15. DE 16. DE 17. DE 18. Show the limits of the delineated erosion hazard zone as determined by the EHZ analysis per DCM Appendix E. Verify existing drainage area boundaries. It appears that drainage area 1a and 1h have been merged. Verify Note 4 of the Existing Drainage Conditions notes. A curve number of 90 does not reflect good condition at greater than 75% of grass cover per DCM Table 2-5. Provide documentation showing that the existing development was approved to participate in the Regional Stormwater Management Program. It is not included in the Engineering Report as the plans state. Provide verification that a previous RSMP agreement covers the proposed development per DCM 8.2.2. Visit the City of Austin's RSMP website at https://www.austintexas.gov/department/regional-stormwater-management-program for the Feasibility meeting Request Form and follow the instructions provided to setup a RSMP Feasibility meeting if one has not already been had. Note that detention may be required. Show all proposed drainage easements on preliminary plan. All drainage easements are to be located adjacent to property lines (not centered on property lines). [LDC 25-7-151] Provide additional information and clarification on the proposed storm drain lines. The proposed storm drainage appears incomplete as it just ends without connecting into an outfall. [LDC 25-7-61] DE 12. Remove the word public from the proposed storm drain labels. DE 13. Specify the type of easement the proposed storm drain is located within. DE 14. Show how stormwater control measures will convey flow off-site. [LDC 25-7-61] Ensure all existing storm drain infrastructure is shown on the storm drain plans per the subdivision application instructions. There appear to be pipes and structures missing. Include the size and material of the infrastructure. Verify that the grading plans are complete. The plans show proposed grades that do not tie into existing contours. [LDC 25-7-61] Specify the limits of proposed roadway improvements to existing roadways. The grading plans appear to show new proposed grades for existing roadways. [LDC 25-7-61] Revise engineering report. There is a statement in the Drainage and Stormwater Management section that is inaccurate. The requirement for on-site detention is not based on the amount of impervious cover. See code and criteria sections LDC 25-7-61, DCM 1.2.2. Environmental Review - Mike McDougal - 512-974-6380 Tuesday, August 30, 2022 EV 01 After additional research, an administrative variance is not required to cross the Critical Water Quality Zone with Elmont Drive per LDC 25-8-262(D). Remove the reference to the variance from the coversheet. Flood Plain Review - Kena Pierce - 512-978-1832 Applicant must remedy all compliance issues without creating additional compliance issues with the LDC and/or Criteria manuals. A response that fails to correct an issue, or which creates other issues does not comply with the LDC and is insufficient to address the comments. The comments provided describe an issue that must be remedied in order for the application to be approved. Any specific examples are provided as a courtesy and are not intended as an exhaustive list, especially as the site may be updated to have additional compliance issues. Contact this reviewer if you have any questions, kena.pierce@austintexas.gov. FP 1. The site, as shown on the plan provided, is not in compliance with the following sections of the Land Development Code. Please correct your application to be in compliance with Code. 25-7-8 – Computation of Storm Runoff a. Please submit the latest approved modeling to intake in order to for the model for this application to be compared to the approved modeling from C8-2020-0004PA. FP 2. The site, as shown on the plan provided, is not in compliance with the following sections of the Land Development Code. Please correct your application to be in compliance with Code. 25-7-33 – Floodplain Maps, Delineation, and Depiction a. Please submit the latest approved modeling to intake in order for the delineation to be verified. ------------------------------------------------------------------------------------------------------------------------- Floodplain Review Notes: General notes: Notes from Katina Bohrer during project assessment C8-2020-0004PA: “Reviewer notes: Riverside at Wickersham. Previously reviewed and approved by Kristi (though several comments indicated that confirmation of compliance would be needed at future stages). Update 4 officially allowed because it’s been a hot minute since the last review (i.e. 1 year) and the engineer has changed and the plan has changed somewhat. Modeling comments below are from a complimentary review of the model completed by Katina on 2/14/2022. Based on a follow-up meeting with the engineer on May 2, 2022, the actual review and approval of any floodplain modifications proposed with this development are actually approved at time of subdivision construction or site plan stage, so at this point we really need to see “proof of concept” since we don’t have things like finalized grading plans. Project Area on main stem: XS 10477 to halfway between 8080/7560; both sides of the creek are the project area between XS10477 and XS9169, left side only for the remaining project area. Project Area on Trib1 is from XS543 to outfall on the left side of the creek. UPDATE 4: Corrected Effective RAS and HMS modeling provided on May 25, 2022 and located on LUR file system, Proposed RAS modeling and updated report provided on June 20, 2022 directly to reviewer and saved on WPD file system. Applicant needs to provide proposed version of the models to DSD Intake at next update. RAS modeling has been accepted as meeting No Adverse Impact requirements. NOTE TO FP REVIEWER: Modeling will need to be confirmed to still match proposed grading, NAI regulations, and that easement contains the post project floodplain on future site development submittals. See other “deferred” comments below which will also need to be addressed at the appropriate site development stage.” During subdivision construction/ site development stage, refer to this PA deferred comments to ensure work is in compliance with code. Subdivision Review - Steve Hopkins - steve.hopkins@austintexas.gov SR 1. This application was formally submitted on August 8, 2022. The deadline to clear comments is November 7, 2022. (LDC 25-1-83) SR 2. On sheet 1, delete the plan submittal table and the revision table. (25-1-83) SR 3. For clarity, remove the following data from sheet 3 “Overall Preliminary Plan” (25-1-83)  CWQZ  Existing floodplain.  Existing and proposed easements. SR 4. Delete the following notes: (25-1-83)  General Note #22 that refers to the CWQZ  General Note #23 that refers to erosion hazard analysis.  Pavement Notes #1-10. These notes belong on the construction plans, not this preliminary plan. SR 5. Revise the City of Austin approval block as follows: 25-1-83 PRELIMINARY SUBDIVISION APPROVAL SHEET 1 OF 5 FILE NUMBER C8-2022-0221 APPLICATION DATE: AUGUST 8, 2022 APPROVED BY LAND USE COMMISSION ON ________________________ EXPIRATION DATE (LDC 25-4-62): AUGUST 8, 2027 CASE MANAGER: _______________________________________ Steve Hopkins, for: Denise Lucas, Director, Development Services Department Final plats must be recorded by the expiration Date. Subsequent Site Pans which do not comply with the Code current at the time of filing and require Building permits or notice of construction (if a building permit is not required), must also be approved prior to the Project Expiration Date. SR 6. Under “General Notes” revise note 18 as follows (25-1-83):  Delete Streets 1, 2, 3 and Café Street  Only reference South Pleasant Valley Road, Wickersham Lane, Elmont Drive, Crossing Place and East Riverside Drive. SR 7. The preliminary plan will be comprised of the coversheet and sheets 2-5. The other sheets will be exhibits. (25-1-83) Water Quality Review - Don Heisch – (512) 978-1736 - Don.Heisch@austintexas.gov Release of this application does not constitute a verification of all data, information, and calculations supplied by the applicant. The engineer of record is solely responsible for the completeness, accuracy, and adequacy of his/her submittal, whether or not the application is reviewed for code compliance by city engineers. WQ 1. Submit a completed landfill certification form. All applications for approval that permit the construction or alteration of a residential, commercial, or public enclosed structure on a site over one acre or a site located within a landfill area shall comply with LDC 25-1-84. The applicant may find the Landfill Certification Form and Landfill Area Overview Map on the City of Austin website using the following link: https://www.austintexas.gov/department/development-over-closed-landfills. WQ 2. The application must be complete and accurate prior to submittal per the Subdivision Application Instruction. This includes the additional Submittal Requirements listed in the Subdivision Application Instructions. Which are necessary to obtain Preliminary Plan Approval. The regulatory requirements and procedures for approval are defined in the Texas Local Government Code and LDC Title 25. WQ 3. Add a water quality plat note that reads as follows: “Water quality controls are required for all development pursuant to the Land Development Code.” Water quality controls are required per LDC 25-8-211. WQ 4. Ensure all impervious cover is being treated by stormwater control measures. Water quality controls are required per LDC 25-8-211. WQ 5. Revise the Engineers Report to be more specific about how water quality controls are being provided for this subdivision per LDC 25-8-213. The proposed description in the report does not appear to be congruent with the proposed plans. WQ 6. Provide a water quality plan with all items specified in the subdivision application packet, page 17. [LDC 25-8-211] WQ 7. Ensure that the proposed schematic plans identify the splitter locations and how the overflow will be conveyed. [LDC 25-8-211] WQ 8. Provide impervious cover total and percentage calculations for each contributing drainage area to the ponds. [LDC25-8-211] WQ 9. Provide associated R table calculations for each of the water quality pond. [LDC 25-8-211] WQ 10. Specify the types of stormwater control measures being proposed. [ECM 1.6.0] WQ 11. Show the drainage area that conveys flow to each stormwater control measure (SCM). Note that there is a limit to the amount of contributing area to SCM. For example, rain gardens are restricted to a contributing drainage area not to exceed two acres and a ponding depth not to exceed 12 inches per ECM 1.6.7.H.2. WQ 12. Show compliance with DCM 1.2.4.E. WQ 13. Revise location of SCMs. SCMs shall meet the requirements of LDC 25-8-261(H). Wetlands Biologist Review - Hank Marley - hank.marley@austintexas.gov No comments at this time. Wetland mitigation review will be conducted at time of site plan or subdivision construction plan review. ERM Review - Hank Marley - hank.marley@austintexas.gov No comments at this time. All proposed floodplain modifications will be reviewed and assessed at time of subdivision construction plan or site plan submittal. City Arborist Review - Taylor Horton -taylor.horton@austintexas.gov CA1 It does not appear a variance is identified to remove Heritage Trees. Tree review will be deferred to site plan submittals. Site Plan Plumbing - Cory Harmon - 512-974-2882 NO REVIEW REQUIRED No proposed plumbing work. End of report