Zoning and Platting CommissionMarch 1, 2022

B-11 (C8J-2021-0163 - Easton Park 4B East Preliminary Plan).pdf — original pdf

Backup
Thumbnail of the first page of the PDF
Page 1 of 12 pages

SUBDIVISION REVIEW SHEET LOT(S): 3 COUNTY: Travis ZAP DATE: March 1, 2022 JURISDICTION: Limited Purpose AGENT: Carlson, Brigance, and Doering,Inc (Charles Brigance) (Matthew McCafferty) CASE NO.: C8J-2021-0163 SUBDIVISION NAME: Easton Park Section 4B East Preliminary Plan AREA: 21.067 acres OWNER/APPLICANT: Carma Easton , LLC ADDRESS OF SUBDIVISION: William Cannon and Finial GRIDS: L12 WATERSHED: North Fork Dry Creek EXISTING ZONING: Planned Unit Development (PUD) MUD PLAN: Pilot Knob MUD PROPOSED LAND USE: Mixed Residential, greenbelt/open space/drainage easement lots, and public ROW VARIANCES: None SIDEWALKS: Sidewalks will be provided along all internal streets and the boundary street. DEPARTMENT COMMENTS: The request is for the approval of the Easton Park 4B East Preliminary Plan. The plan is comprised of 3 lots on 21.067 acres, proposing 1 mixed residential lot, and 2 other lots for greenbelt/open space/drainage easement, and approximately 1,905 linear feet of right-of-way/streets. The property connects to William Cannon Road to the north and will realign a portion of Finial Drive (formerly named Colton Bluff Springs Road). The applicant also proposes to abandon a portion of Finial Drive for the realignment. The owners have submitted an application for this process with Travis County, and has received pre-approval from utility providers and other parties to the street abandonment area. Staff will be coordinating the abandonment application with the final plat application (out of this preliminary plan) to Court for final approval. Sidewalks are proposed on all streets. The proposed lots comply with the PUD zoning requirements for use and lot size. Parkland will be in compliance with the PUD. Water and wastewater will be provided by the City of Austin. Staff recommends approval of the preliminary plan, subject to the conditions listed in the attached comment report. After the conditions are met, the plan will comply with LDC 30-2-84. The conditions include remove or update notes, define easements, update engineer’s report and drainage information, etc. These are administrative actions that require no discretionary review. An application that has been approved with conditions may be updated to address those conditions until the application expires and the plan does not need to be heard before the Commission again. STAFF RECOMMENDATION: Staff recommends approval of the preliminary plan, subject to the conditions listed in the comment report dated February 24, 2022 and attached as Exhibit C. CASE MANAGER: Sue Welch, Travis County Single Office Email address: Sue.Welch@traviscountytx.gov Exhibit A: Easton Park 4B East Preliminary Plan Exhibit B: Easton Park 4B Location Map Exhibit C: Easton Park 4B East Preliminary Plan Comment Report PHONE: 512-854-7637 CITY OF AUSTIN – TRAVIS COUNTY – SINGLE SUBDIVISION OFFICE SUBDIVISION APPLICATION – MASTER COMMENT REPORT February 24, 2022 UPDATE: PHONE #: U0 512-854-7637 C8J-2021-0043 00 Easton Park 4B-East Preliminary 8200 FINIAL DR CASE NUMBER: REVISION #: CASE MANAGER: Sue Welch PROJECT NAME: LOCATION: SUBMITTAL DATE: January 31, 2022 REPORT DUE DATE: February 24, 2022 FINAL REPORT DATE: STAFF REPORT: This report includes all staff comments received to date concerning your most recent subdivision application submittal. The comments may include requirements, recommendations, or information. The requirements in this report must be addressed by an updated submittal. The subdivision application will be approved when all requirements from each review discipline have been addressed. If you have any questions, concerns or if you require additional information about this report, please contact your case manager at the phone number listed above or by using the contact information listed for each reviewer in this report. Any change to the plan/plat shall not cause noncompliance with any applicable code or criteria. In addition, any change to the plat may trigger new comments. UPDATE DEADLINE (LDC 30-2-56; 30-2-82): All comments must be addressed by filing an updated submittal prior to the update deadline of (90 days from submittal) which is May 3, 2022. Otherwise, the application will expire. If this date falls on a weekend or City of Austin holiday, the next City of Austin workday will be the deadline. Extension of Review Period, Extension of Update Deadline and Tolling of Application Period do not apply to applications for preliminary plan, plat or subdivision construction plans (LDC). UPDATE SUBMITTAL INSTRUCTIONS (LDC 30-1-113): 1. 2. a. b. 3. list of approved submittal dates. REVIEWERS: Planner 1 : Sophia Briones Site Plan Plumbing : Cory Harmon Travis Co. Subdivision : Sue Welch Travis Co. Drainage: Christine Connor Environmental : Mel Fuechec Flood Plain : Katina Bohrer Land Development Engineering - Jennifer Back, P.E. PARD / Planning & Design : Robynne Heymans AW Utility Development Services : Derek Tucker Water Quality : Don Heisch Applicants must contact Intake Staff (974-1770) in order to submit an update. Your update must include the following items: The revised plat/plan in pdf format A letter that addresses each comment in the master comment report Updates must be submitted on an approved submittal date. Refer to the submittal calendar for a Electric Review - Andrea Katz - 512-322-6957 No Review Required. Out of Austin Energy service area, served by Bluebonnet Electric Cooperative, Inc. 911 Addressing Review - Jorge Perdomo - 512-974-1620 AD1: This plat review is cleared; however, any changes to street names, street name labels, or street layouts will require a new review. NOTES: Addressing recommends updating label for E William Cannon Dr without punctuation point. i.e. ‘E.’ to ‘E’ § 30-2-155 Environmental Review - Mel Fuechec - mel.fuechec@austintexas.gov ADMINISTRATIVE VARIANCE [LDC 25-8, Article 1] EV 1 An Administrative Environmental Variance is required to vary the requirements of the following: • Section 25-8-341 (Cut Requirements) • Section 25-8-342 (Fill Requirements) Complete the following to proceed with the variance: • Contact this reviewer at mel.fuechec@austintexas.gov@austintexas.gov for a copy of the administrative variance request form; • Complete the form and identify the scope / extent of the Administrative Environmental Variances request; • Return the form to this reviewer; • Add a note to the cover sheet stating: “An administrative variance has been granted in accordance with LDC 25-8-42 to allow: Cut and Fill from 4 to 8 feet in the desired development zone. [LDC 25-8-342]” • Pay the Administrative Environmental Variance fee and provide receipt of payment in order to clear this comment. [LDC 25-8, Article 1] Flood Plain Review - Katina Bohrer - 512-974-3558 Reviewer notes: Culvert modeling initially reviewed and approved with PA for C8J-2020-0148% and C8J-2021-0043PA. At the PA stage, the proposed culverts (proposed to be built under different plans than this) resulted in adverse flood impacts which must be proven to be mitigated by the time the culvert is permitted to be built (i.e. subdivision construction). The applicant’s engineer indicated that they would pursue easement acquisition to prove compliance with No Adverse Impact requirements at Sub Const. NOTE TO REVIEWER: Floodplain report, including pre, post, and FEMA FP maps is contained as an appendix to the Engineer’s report (in AMANDA as 12/15/21 Eng Report). In Date: 10/7/2021 Notice to applicant: Applicant must remedy all compliance issues without creating additional compliance issues with the LDC and/or Criteria manuals. A response that fails to correct an issue, or which creates other issues does not comply with the LDC and is insufficient to address the comments. The comments provided describe an issue that must be remedied in order for the application to be approved. Any specific examples are provided as a courtesy and are not intended as an exhaustive list, especially as the site may be updated to have additional compliance issues. Contact this reviewer if you have any questions at Katina.Bohrer@austintexas.gov FP1. The site, as shown on the plan provided, is not in compliance with the following sections of the Land Development Code. Please correct your application to be in compliance with Code. 30-4-5 – Determination of the 100-year floodplain 30-4-7 – Computation of Stormwater Runoff 30-4-31 – Single Office Authorized to Require Drainage Studies 30-4-33 – Floodplain Maps, Delineation, and Depiction 30-4-61 – Criteria for Approval of Development Applications 30-4-62 – Certificate of Professional Engineer Required for Certain Alterations and Improvements 30-4-64 – Design and Construction of Drainage Facilities and Improvements 30-4-152 – Dedication of Easements and Rights-of-Way Detailed information: a. The associated HMS/RAS for floodplain was not included in the submittal. Please submit the associated modeling for a complete case file and concurrence it still matches the current submitted plan. b. Why is the entire subdivision construction plan for Prospect Park (adjacent lot) provided for this submittal? Was it to prove that the Prospect Park project is taking into account the Cota Vista crossing and the rises will be contained to drainage easement on that property? c. The previously reviewed and approved modeling for this project showed a rise in Water Surface Elevation upstream of the proposed Cota Vista Drive crossing. It appears that the lot just upstream of Cota Vista is a proposed DE/Open Space lot which is fine for this site; but it will need to be proven that the lots upstream of this site have adequate drainage easement to contain the post project floodplain. The easement will be necessary to get subdivision construction approval. (FYI: Prospect Park is to the south [C8J-2021-0148%] and an unknown Easton Park subdivision to the north [maybe it’s Easton Park 3A [C8J- 2018-0105%]? Per GIS, it appears that the lot to the north of the tributary is unplatted, but I suspect it’s actually within one of the Easton Park submittals]) (highlighted lot below is the one I’m concerned about, it is directly to the west of the Easton Park 4B East Prelim, and on the north side of the tributary – it will need to be proven that the post project floodplain is contained to drainage easement in this area at Subdivision Construction) FP2. The site, as shown on the plan provided, does not meet requirements set in the Drainage Criteria Manual Section 1 “Drainage Policy.” Please correct your application to be in compliance with Criteria. Detailed information: a. The associated HMS/RAS for floodplain was not included in the submittal. Please submit the associated modeling for a complete case file and concurrence it still matches the current submitted plan. FP3. The modeling provided does not meet requirements set in the Drainage Criteria Manual Section 2 “Determination of Storm Run Off.” Modeling must be in compliance with criteria prior to approval. Detailed Information: a. The associated HMS/RAS for floodplain was not included in the submittal. Please submit the associated modeling for a complete case file. FP4. The modeling provided does not meet requirements set in the Drainage Criteria Manual Section 6 “Open Channels.” Modeling must be in compliance with criteria prior to approval. Detailed Information: a. The associated HMS/RAS for floodplain was not included in the submittal. Please submit the associated modeling for a complete case file and concurrence it still matches the current submitted plan. Wetlands Biologist Review - Leslie Lilly - Leslie.lilly@austintexas.gov WB No Review Required Travis Co. Subdivision Review - Sue Welch - 512-854-7637 1. Add “drainage” to the open space/greenbelt lots on the table on page 1. 30-1-113 2. FYI - The proposed abandonment of Finial by Court will need to be coordinated with the final plat. 3. FYI - An Educational Impact Statement may be required. Refer to Exhibit IV of the application. It is the responsibility of the applicant to submit the EIS to the appropriate school district. 25-1-83 or 30-1-113 Travis Co. Transportation Review - Christine Connor - 512-854-7215 No comments. Travis Co. Drainage Construction Review - Christine Connor - 512-854-7215 1) Provide proof of the CLOMR approval with the plat submittal. The plat will not be accepted for formal review with that approval. 2) It is unclear why the Prospect Park plans were provided. Proof that a revision to change the pond has been submitted and approved will be required with the plat. 3) See COA Floodplain comments Land Development Engineering - Jennifer Back, P.E. - jennifer.back@austintexas.gov Release of this application does not constitute a verification of all data, information, and calculations supplied by the applicant. The engineer of record is solely responsible for the completeness, accuracy, and adequacy of his/her submittal, whether or not the application is reviewed for code compliance by city engineers. 1. It appears plans for Prospect Park construction plans were also submitted. Please clarify if there is a revision – additional comments will be made with that application C8J-2020-0148.1B PARD / Planning & Design Review - Robynne Heymans - 512-974-9549 PR1: Please update note 10 to include lot 2 Block B (The area to be dedicated as parkland is shown on this preliminary plan as Lot 3 Block F and Lot 2 Block B) PR 2: Please show the proposed trail alignment on this prelim. Show how the trail connects to parkland in Prospect Park Phase I to the north. PR 3: Please provide an updated master parkland tracking table including the units in this preliminary plan as well as the number of acres of parkland and open space owed. Site Plan Plumbing - Cory Harmon - 512-974-2882 The case number in AMANDA is C8J-2021-0043 for a preliminary plan for a subdivision; however, the case number on the plans submitted is C8J-2020-0148.1B and the plans are construction plans. Please explain this discrepancy. AW Utility Development Services - Derek Tucker - 512-972-0077 AW1. Provide document number for waterline easement. AW2. Provide approval from Jason Inge concerning finial abandonment discussed in memo sent by Brookfield Properties. AW3. Per Utility Criteria Manual Section 2, §15-9, §30-2, §25-5, §25-9, and the Uniform Plumbing Code: The landowner intends to serve each lot with City of Austin water and wastewater utilities. Each lot must have a separate water and wastewater utility connection and no existing or proposed plumbing may cross lot lines. The landowner, at own expense, will be responsible for providing the water and wastewater utility improvements, offsite main extensions, system upgrades, utility relocations and or abandonments to serve each lot. FYI. The landowner must pay the tap and impact fee once the landowner makes an application for a City of Austin water and wastewater utility tap permit. Water Quality Review - Don Heisch – (512) 978-1736 - Don.Heisch@austintexas.gov Release of this application does not constitute a verification of all data, information, and calculations supplied by the applicant. The engineer of record is solely responsible for the completeness, accuracy, and adequacy of his/her submittal, whether or not the application is reviewed for code compliance by city engineers. WQ 1. WQ 2. WQ 3. WQ 4. Demonstrate or discuss how all impervious cover will be treated as per LDC 30-5-211. Areas in question are areas of impervious cover that are located downstream of the water quality pond. Provide an erosion hazard zone analysis per LDC 30-5-261(H)(5) and DCM Appendix E. A portion of Lot 2 Block B appears to encroach the Erosion Hazard Zone Review Buffer. Design side slopes to comply with DCM 1.2.4.E.8.b. The proposed water quality pond has side slopes greater than 3:1. Further coordination is required to determine whether a pump is allowed for a City maintained pond per DCM 1.2.4.E.11. END OF REPORT 13SHEETOFJOB NUMBERDATEDESIGNEDBY:DRAFTEDBY:BDFIRM ID #F3791Carlson, Brigance & Doering, Inc.CJOB NAME:PROJECT:SHEET NAME:Main Office5501 West William Cannon Dr.Austin, Texas 78749Phone No. (512) 280-5160Civil Engineering SurveyingNorth Office12129 RR 620 N., Ste. 600Austin, Texas 78750www.cbdeng.com5307EASTON PARK SECTION 4B EASTPRELIMINARY PLANCBCPNOV 2021C8J-2021-016317November11/17/2021 2GENERAL NOTES3SHEETOFJOB NUMBERDATEDESIGNEDBY:DRAFTEDBY:BDFIRM ID #F3791Carlson, Brigance & Doering, Inc.CJOB NAME:PROJECT:SHEET NAME:Main Office5501 West William Cannon Dr.Austin, Texas 78749Phone No. (512) 280-5160Civil Engineering SurveyingNorth Office12129 RR 620 N., Ste. 600Austin, Texas 78750www.cbdeng.com5307EASTON PARK SECTION 4B EASTPRELIMINARY PLANCBCPNOV 2021C8J-2021-016311/17/2021 3PRELIMINARY PLAT - 100 SCALE3SHEETOFJOB NUMBERDATEDESIGNEDBY:DRAFTEDBY:BDFIRM ID #F3791Carlson, Brigance & Doering, Inc.CJOB NAME:PROJECT:SHEET NAME:Main Office5501 West William Cannon Dr.Austin, Texas 78749Phone No. (512) 280-5160Civil Engineering SurveyingNorth Office12129 RR 620 N., Ste. 600Austin, Texas 78750www.cbdeng.com5307EASTON PARK SECTION 4B EASTPRELIMINARY PLANCBCPNOV 2021C8J-2021-016311/17/2021 Easton Park 4B East Location Map Legend County Jurisdiction FULL PURPOSE LIMITED PURPOSE OTHER CITY LIMITS OTHER CITIES ETJ TCAD Parcels Jurisdiction FULL PURPOSE LIMITED PURPOSE OTHER CITY LIMITS OTHER CITIES ETJ Zoning Text EXTRATERRITORIAL JURISDICTION 2 MILE ETJ AGRICULTURAL AGREEMENT EXTRATERRITORIAL JURISDICTION 2 MILE ETJ AGRICULTURAL AGREEMENT Site 0.3 2-2-21 NAD_1983_StatePlane_Texas_Central_FIPS_4203_Feet 0 0.15 0.3 Miles This product is for informational purposes and may not have been prepared for or be suitable for legal, engineering, or surveying purposes. It does not represent an on-the-ground survey. This product has been produced by the City of Austin for the sole purpose of geographic reference. No warranty is made by the City of Austin regarding specific accuracy or completeness. 1: 9,600 Notes Easton Park 4B Location