Zoning and Platting CommissionJan. 5, 2021

B-06 (SP-2017-0483D(R1) - West Travis County Public Utility Agency; District 8).pdf — original pdf

Backup
Thumbnail of the first page of the PDF
Page 1 of 9 pages

ZONING AND PLATTING COMMISSION SITE PLAN CONDITIONAL USE PERMIT REVIEW SHEET CASE NUMBER: SP-2017-0483D(R1) PLANNING COMMISSION DATE: 01/05/2021 8 2.02 acres, limits of construction Jennifer Riechers West Travis County Public Utility Agency 13215 Bee Caves Parkway, Bldg B, Ste. 110 Bee Cave, Texas 78738 512-263-0100 PROJECT NAME: West Travis County Public Utility Agency storage tank revision PROPOSED USE: Water Utility (existing) ADDRESS OF APPLICATION: 10710-1/2 W SH 71 AREA: COUNCIL DISTRICT: APPLICANT: AGENT: CASE MANAGER: Christine Barton-Holmes, CNUa, LEED AP EXISTING ZONING: P PROPOSED DEVELOPMENT: The applicant is requesting to revise a previously approved permit to add a second ground storage tank, with associated improvements, on a site zoned P that is greater than one acre in size; therefore, a Conditional Use Permit is required, according to the Land Development Code {Section 25-2-625}. SUMMARY STAFF RECOMMENDATION: Staff recommends approval of the conditional use permit. The site plan will comply with all requirements of the Land Development Code prior to its release. PREVIOUS ZONING AND PLATTING COMMISSION ACTION: NA Murfee Engineering Company, Inc. 1101 Capitol of Texas Highway South Bldg D, Ste. 110 Austin, Texas 78746 512-327-9204 christine.barton-holmes@austintexas.gov Telephone: 974-2788 WATERSHED: Barton Creek Watershed – Barton Springs Zone APPLICABLE WATERSHED ORDINANCE: Current/ Comprehensive watershed ordinance T.I.A.: Not Required B-061 of 9 LIMITS OF CONSTRUCTION: 2.02 acres PROPOSED BLDG. CVRG: NA PROPOSED IMP. CVRG: 24.6% PROPOSED HEIGHT: NA PROVIDED PARKING: NA PROPOSED USE: Wastewater Treatment PROJECT INFORMATION: ZONING: P MAX. BLDG. COVERAGE: * MAX. IMPERV. CVRG.: * MAX HEIGHT: * REQUIRED PARKING: NA EXIST. USE: Water Utility *P zoning development standards to be determined by approval of a conditional use site plan [25-2-625(D)(2)] SUMMARY COMMENTS ON SITE PLAN: Land Use: The applicant proposes to add one additional 950,000-gallon ground storage tank to the facility, bringing the total number of tanks to two. The site plan will comply with all requirements of the Land Development Code prior to its release. Staff recommends approval of the conditional use permit Environmental: The site is in the Barton Creek watershed, which is within the Barton Springs Zone. There are no known Critical Environmental Features are located within the limits of construction. Transportation: Access is available from SH 71 SURROUNDING CONDITIONS: Zoning/ Land use North: SF-6 (Undeveloped) East: P, SF-4A (Undeveloped) South: MF-1, Southwest Parkway (Undeveloped and highway) West: ETJ & SH-71 (Undeveloped, single-family, and highway) R.O.W. 200’ Street SH 71 NEIGHBORHOOD ORGANIZATIONS: N/A Surfacing 85’ Classification Highway B-062 of 9 CONDITIONAL USE PERMIT REVIEW AND EVALUATION CRITERIA The following evaluation is included to provide staff position on each point of the conditional use permit criteria. Section 25-5-145 of the Land Development Code states: “The Commission shall determine whether the proposed development or use of a conditional use site plan complies with the requirements of this section. A conditional use site plan must: 1. Comply with the requirements of this title; Staff response: This application complies with the requirements of this title. 2. Comply with the objectives and purposes of the zoning district; Staff response: This application complies with the objectives and purposes of the zoning districts and overlays. 3. Have building height, bulk, scale, setback, open space, landscaping, drainage, access, traffic circulation, and use that are compatible with the use of an abutting site; Staff response: This application is compatible with the abutting sites in all of these cases. 4. Provide adequate and convenient off-street parking and loading facilities; Staff response: Adequate parking and loading facilities exist at the site. 5. Reasonably protect persons and property from erosion, flood, fire, noises, glare, and similar adverse effects; Staff response: The proposed project does not contribute to any of these adverse effects. 6. For conditional use located within the East Austin Overlay district, comply with the goals and objectives of a neighborhood plan adopted by the City Council for the area in which the use is proposed. Staff response: The proposed project is not in the East Austin Overlay district. A Conditional Use Site Plan May Not: 1. More adversely affect an adjoining site than would a permitted use; Staff response: The site plan will conform with all regulations and standards established by the Land Development Code. This proposed site plan does not more adversely affect an adjoining site than would a permitted use. 2. Adversely affect the safety or convenience of vehicular or pedestrian circulation, including reasonably anticipated traffic and uses in the area; Staff response: Access is limited into the site, and surrounding vehicular circulation in the area of the project is not anticipated to have any detriment to safety or convenience. 3. Adversely affects an adjacent property or traffic control through the location, lighting, or type of signs; Staff response: No signage or lighting is proposed that would affect adjacent properties or traffic control. B-063 of 9 WTC PUBLIC UTILITY AGENCY SITE DEVELOPMENT PERMIT PLANS FOR SOUTHWEST PARKWAY GROUND STORAGE TANK #2 10710 1/2 W. SH 71, AUSTIN, TX 78736 BARTON CREEK BEE CAVE ETJ SHEET NO. I I Y C N E G A Y T L T U C L B U P C T W I I R O F S N A L P T M R E P T N E M P O L E V E D E T S I 2 # K N A T E G A R O T S D N U O R G Y A W K R A P T S E W H T U O S NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. ALL RESPONSIBILITY FOR THE ADEQUACY OF THESE PLANS REMAINS WITH THE ENGINEER WHO PREPARED THEM. IN APPROVING THESE PLANS, THE CITY OF AUSTIN MUST RELY UPON THE ADEQUACY OF THE WORK OF THE DESIGN ENGINEER. THIS PROJECT IS LOCATED IN THE CITY OF AUSTIN LIMITED PURPOSE. THIS PROJECT IS LOCATED IN THE BARTON CREEK WATERSHED, CLASSIFIED AS BARTON SPRINGS ZONE AND IS WITHIN THE EDWARDS AQUIFER CONTRIBUTING ZONE. NO PORTION OF THIS SITE LIES WITHIN A DESIGNATED FLOOD HAZARD ZONE BASED ON FLOOD INSURANCE RATE MAP, PANEL #48453C0420H, TRAVIS COUNTY, TEXAS AND INCORPORATED AREAS, EFFECTIVE DATE SEPTEMBER 26, 2008. 2.02 ACRES OUT OF THE MRS L MADDEN SURVEY 206, ABSTRACT 2283, AS RECORDED IN DOCUMENT NO. 2012106240 OPRTCT. PROJECT IS SUBJECT TO WATERWAY DEVELOPMENT PERMIT NO. 7280, APPROVED ON NOV. 4, 1983 AND NOT SUBJECT TO WATERSHED PROTECTION REGULATIONS. BENCHMARK: TBM WL-10, COTTON GIN SPINDLE SET IN POWER POLE NO. 351622, APPROXIMATELY 17' SOUTHEAST OF ANGLE POINT IN THE SOUTH FENCE. ELEVATION = 983.06'. F.B. 1804/P. 38. RELEASE OF THIS APPLICATION DOES NOT CONSTITUTE A VERIFICATION OF ALL DATA, INFORMATION, AND CALCULATIONS SUPPLIED BY THE APPLICANT. THE ENGINEER OF RECORD IS SOLELY RESPONSIBLE FOR THE COMPLETENESS, ACCURACY, AND ADEQUACY OF HIS SUBMITTAL, WHETHER OR NOT THE APPLICATION IS REVIEWED FOR CODE COMPLIANCY BY CITY ENGINEERS. ENGINEER CERTIFIES THAT THE PLAN IS COMPLETE, ACCURATE, AND IN COMPLIANCE WITH CHAPTER 25 OF THE LAND DEVELOPMENT CODE. 10. APPROVAL OF THESE PLANS BY THE CITY OF AUSTIN INDICATES COMPLIANCE WITH APPLICABLE CITY REGULATIONS ONLY, APPROVAL BY OTHER GOVERNMENTAL ENTITIES MAY BE REQUIRED PRIOR TO THE START OF CONSTRUCTION. THE APPLICANT IS RESPONSIBLE FOR DETERMINING WHAT ADDITIONAL APPROVALS MAY BE NECESSARY. SUBMITTED FOR APPROVAL BY: MURFEE ENGINEERING COMPANY, INC. REGISTERED PROFESSIONAL ENGINEER 04/15/2020 DATE APPROVED BY: WEST TRAVIS COUNTY PUBLIC UTILITY AGENCY DEVELOPMENT SERVICES DEPARTMENT SP-2017-0483D(R1) SITE PLAN PERMIT NUMBER REVIEWED BY: DATE DATE DATE ) e l t i t ( g w d s . l i a t e D s e t o N e \ I \ l t i T S N A L P _ T M R E P n o i t c u r t s n o C \ 0 1 1 \ 1 5 0 \ 1 1 \ : O : E L F I Number Description REVISIONS / CORRECTIONS Revise (R) Add (A) Void (V) Sheet No.'s Total # Sheets in Plan Set Net Change Imp. Cover (sq. ft.) Total Site Imp. Cover (sq. ft.)/% City of Austin Approval Date Date Imaged T.N.R. AUSTIN LTD ARROYO CANYON DR. 1 7 H S PROJECT LOCATION AUSTIN ETJ S O U T H W E S T P A R K W A Y WEST TRAVIS COUNTY PUBLIC UTILITY AGENCY LOCATION MAP SCALE: N.T.S. MAPSCO PAGE 581J, GRID "A-23" OWNER 13215 BEE CAVES PARKWAY BUILDING B, SUITE 110 BEE CAVE, TEXAS 78738 PH: (512) 263-0100 ENGINEER MURFEE ENGINEERING COMPANY, INC. 1101 CAPITAL OF TEXAS HIGHWAY SOUTH BUILDING D, SUITE 110 AUSTIN, TEXAS 78746 PH: (512) 327-9204 FAX: (512) 327-2947 PROPERTY DESCRIPTION 2.02 ACRES OUR OF THE MRS L MADDEN SURVEY 206 ABSTRACT 2283 AS RECORDED IN DOCUMENT NO. 2012106240 OPRTCT PROPERTY ADDRESS 10710 2 1 W. SH 71 AUSTIN, TEXAS 78735 SUBMITTAL DATE MAY 7, 2020 1. 2. 3. 4. 5. 6. 7. 8. 9. COVER SHEET GENERAL NOTES 1 GENERAL NOTES 2 OVERALL SITE PLAN EXISTING DRAINAGE AREA MAP PROPOSED DRAINAGE AREA MAP SITE PLAN EROSION CONTROL PLAN STANDARD DETAILS GST #2 10. RENDERING MAP SITE PLAN RELEASE NOTES: A. B. C. D. F. G. H. ALL IMPROVEMENTS SHALL BE MADE IN ACCORDANCE WITH THE RELEASED SITE PLAN. ANY ADDITIONAL IMPROVEMENTS WILL REQUIRE SITE PLAN AMENDMENT AND APPROVAL OF THE DEVELOPMENT SERVICES DEPARTMENT. APPROVAL OF THIS SITE PLAN DOES NOT INCLUDE BUILDING AND FIRE CODE APPROVAL NOR BUILDING PERMIT APPROVAL. ALL SIGNS MUST COMPLY WITH REQUIREMENTS OF THE LAND DEVELOPMENT CODE (CHAPTER 25-10). ADDITIONAL ELECTRIC EASEMENTS MAY BE REQUIRED AT A LATER DATE. E. WATER AND WASTEWATER SERVICE WILL NOT BE REQUIRED. ALL EXISTING STRUCTURES SHOWN TO BE REMOVED WILL REQUIRE A DEMOLITION PERMIT FROM THE CITY OF AUSTIN DEVELOPMENT SERVICES DEPARTMENT. A DEVELOPMENT PERMIT MUST BE ISSUED PRIOR TO AN APPLICATION FOR BUILDING PERMIT FOR NON-CONSOLIDATED OR ZONING & PLATTING COMMISSION APPROVED SITE PLANS. FOR DRIVEWAY CONSTRUCTION: THE OWNER IS RESPONSIBLE FOR ALL COSTS FOR RELOCATION OF, OR DAMAGE TO UTILITIES. I. FOR CONSTRUCTION WITHIN THE RIGHT-OF-WAY, A ROW EXCAVATION PERMIT IS REQUIRED. SP-2017-0483D(R1) 10710 1/2 W SH 71 1101 SOUTH CAPITAL OF TEXAS HIGHWAY BUILDING D, SUITE 110 AUSTIN, TEXAS 78746 (512) 327-9204 MURFEE ENGINEERING COMPANY 4-15-20B-064 of 9 B-065 of 9 B-066 of 9 B-067 of 9 B-068 of 9 B-069 of 9