Historic Landmark Commission – Dec. 2, 2026

19.1 - 2220 E Windsor Rd - Drawings — original pdf

Backup
Thumbnail of the first page of the PDF
Page 1 of 28 pages

HIGHEST ADJACENT GRADE 556 6 X 17 COURTYARD PERGOLA GRILL NORTHCOURTYARD 15 X 17 MUD/OFFICE 15'-8" X 8'-6" GARAGE STORAGE 5' X 14'-8" POTTING SHED/ DOG WASH 6' X 10'-4" PORTECOCHERE 12 X 21'-5" DOGDOOR STAIR OPEN TO ABOVE MUDBATH LAUNDRY 16' X 8'-3" CLOSET ARCH READING NOOK 6'-2" X 15 12 DN PRIMARY CLOSET 12'-10" x 16'-6" LAUNDRY PASS-THRU W/D W/D PRIMARY GALLERY 9'-4" X 6' COFFEE BAR ARCH KNEESPACE @ VANITY PRIMARY BATH 14'-10" X 12'-10" LINEARDRAIN LINEN PRIMARY BEDROOM 18'-10" X 22' VAULTEDCEILING FIREPLACE PRIMARY TERRACE DN POWDER ROOM 12 12 UP UP BREAKFAST 12'-10" X 13'-3" PANTRY STORAGE 7' X 6'-5" PULL-OUT TRASH FLOWER FLOWER ARRANGING ARRANGING 6'-6" X 11' 6'-6" X 11' REFRIGERATOR FREEZER SCREEN/ DIVIDER SITTING14'-3" X SITTING14'-3" X 19'-2" 48" RANGE W/ 48" VENT HOOD KITCHEN 19'-2" X 15 KITCHEN 19'-2" X 15 12 12 UP UP GALLERY 47'- 4" X 8 STAIR UP 12 UP ENTRY21 X11'-1" WATER FEATURE 12 UP ENTRYTERRACE 10'-21 2" DN DN 12 BARRELVAULT@ HALL FUTURE ELEVATOR DW BUTLER'S PANTRY 9' X 9'-3" PULL-OUT TRASH DW DW STORAGE STORAGE DN 12 DN DINING14 X 19 CLOSET FRAME COVER & FRAME STRUCTURE W/ WOOD DECK TO BE REMOVED 4'-6" TALL METAL FENCE 3'-0" WIDE GATE W/ AUTO CLOSER FOR POOL COMPLIANCE 4'-6" TALL METAL FENCE 4'-234" 1 4'-1" 9'-93 3'-0"6'-93 4" 4" POOL23' X 12' 38'-0" COLONNADE/PERGOLA W/ BENCH WALL FLANKING EAST EDGE OF GARDEN OR POOL 4'-0" WIDE X 4'-6" TALL GATE W/ AUTO CLOSER FOR POOL COMPLIANCE FINISHED SEAT HEIGHT @ 13" A.F.F. LIVING28 X 21 LIVING28 X 21 FIRE PLACE BAR DN 12 ENTRYPORCH 18 X 12 DN 12 LIVINGTERRACE DN 12 ENTRYSTAIR PATH TOGARDEN LOWEST ADJACENT GRADE 540.5 R16'-9" 38'-0" PLANTER 6'-0"4'-0" 9'-0" 4'-0" 9'-6" 1'-0" 1 GUEST PARKING 0" 7'-1 6 6'-512" 4 " 5 - ' 9 R 2'-0" 2 18'-6" 6'-4" 1 R9'-7" DRIVEWAY I E C N E D S E R Y E L A H D A O R R O S D N W I T S A E 0 2 2 2 3 0 7 8 7 S A X E T , N I T S U A NOT PUBLISHED. ALL RIGHTS RESERVED BY MICHAEL T. LANDRUM, INC. DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF MIICHAEL T. LANDRUM, INC, ISSUED TO DESCRIBED DESIGN INTENT. THEY ARE NOT TO BE USED ON OTHER PROJECTS OR EXTENTIONS TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO TO MICHAEL T. LANDRUM, INC. CONTRACTOR, SUB-CONTRACTORS & SUPPLIERS ARE RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AND CONDITIONS AT JOB SITE, AND SHALL BE RESPONSIBLE FOR ALL LABOR & MATERIALS REQUIRED IN ACCORDANCE WITH DESIGN INTENT. MICHAEL T. LANDRUM, INC. WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE CODES AND ORDINANCES. IN CONNECTION WITH THIS PROJECT. . C N I , M U R D N A L . T L E A H C I M t e e r t s s s o r l u s 2 0 5 1 6 0 0 7 7 S A X E T , N O T S U O H - 5 0 6 4 3 2 6 3 1 7 - i m o c . c n m u r d n a l t l e a h c m @ l e a h c m i i REVISIONS 10.07.26 ISSUE FOR PERMIT DATE: 10.07.26 SHEET DESCRIPTION: SHEET DESCRIPTION: ARCHITECTURAL DRAWING ARCHITECTURAL DRAWING SITE PLAN SCALE: 1/16" = 1'-0" SHEET NUMBER: SHEET NUMBER: A 0.01 Copyright Michael T. Landrum, Inc. Copyright Michael T. Landrum, Inc. 2025 2025 14" 4'-5 1 9'-53 4" LEGEND EXISTING FOOTPRINT OF THE HOUSE TO REMAIN EXISTING EXTERIOR WALLS EXISTING EXTERIOR WALLS TO REMAIN TOTAL LINEAR FOOTAGE OF EXTERIOR PERIMETER WALLS TOTAL LINEAR FOOTAGE OF EXTERIOR WALLS TO BE DEMOLISHED TOTAL LINEAR FOOTAGE OF EXTERIOR WALLS TO REMAIN - 307 L.F. - 142 L.F. - 165 L.F. (53.7% OF ORIGINAL) GENERAL NOTES: 1. DEMO ALL EXISTING EXTERIOR DOOR & WINDOW UNITS. 2. DEMO ALL EXISTING FINISH FLOOR MATERIALS. 3. DEMO ROOF STRUCTURE. 4. SALVAGE STONE VENEERS. NOTE: AVERAGE NATURAL GRADE 548.25 LOT SIZE 38,514 S.F. IMPERVIOUS COVERAGE CALCULATIONS 1ST FLOOR CONDITIONED AREA ATTACHED COVERED PARKING COVERED PATIO/PORCH TOTAL BUILDING AREA TOTAL BUILDING COVERAGE (TBC) DRIVEWAY SIDEWALKS/STEPS/FLATWORK UNCOVERED PATIO EXISTING S.F. NEW/ADDED S.F. TOTAL S.F. 2024 S.F. 443 S.F. 2467 S.F. 2467 S.F. 2623 S.F. 423 S.F. 3184 S.F. 614 S.F. 879 S.F. 4677 S.F. 4677 S.F. 2841 S.F. 848 S.F. 1989 S.F. 5208 S.F. 1057 S.F. 879 S.F. 7144 S.F. 7144 S.F. 5464 S.F. 1271 S.F. 1989 S.F. UNCOVERED WOOD DECKS (COUNTED @ 50%) A/C & EQUIPMENT PADS TOTAL SITE IMPERVIOUS COVERAGE 5513 S.F. 100 S.F. 10,455 S.F. 100 S.F. 15,968 S.F. TOTAL COVERAGE (41.4%) ALLOWABLE COVERAGE (45%) 15,968 S.F. 17,331 S.F. MAIN DWELLING A.) FIRST FLOOR CONDITIONED AREA B.) SECOND FLOOR CONDITIONED AREA C.) LOWER LEVEL CONDITIONED AREA D.) COVERED PARKING E.) COVERED PATIO, DECK, PORCH F.) BALCONY G.) OTHER COVERED/ROOFED AREA H.) UNCOVERED WOOD DECK I.) UNCOVERED TERRACE TOTAL BUILDING AREA (TOTAL A THRU I) J.) POOL K.) REMODELED FLOOR AREA, EXCLUDING ADDITION/NEW CONSTRUCTION DWELLING 2 2ND FLOOR CONDITIONED AREA BALCONY 5208 S.F. 1737 S.F. 742 S.F. 1057 S.F. 879 S.F. 334 S.F. 172 S.F. 917 S.F. 11,046 S.F. 276 S.F. 9,022S.F. 765 S.F. 245 S.F. LEGAL DESCRIPTION LOT 22, ENFIELD "D", A SUBDIVISION IN TRAVIS COUNTY, TEXAS, ACCORDING TO THE MAP OR PLAT THEREOF RECORDED IN VOLUME 3 PAGE 158 OF THE PLAT RECORDS OF TRAVIS COUNTY, TEXAS. LOCATED AT 2220 EAST WINDSOR ROAD OWNERS BRIAN AND CAROLINE HALEY 2220 EAST WINDSOR ROAD AUSTIN, TEXAS 78703 5' TALL CHAIN-LINK TREE PROTECTION FENCING @ FULL CRZ 8" NATURAL WOOD MULCH AC CESS ROUTES 1/2 CRZ 1/4 CRZ UT O AINT ASH W P ETE UT R C O N ASH O C W BLE RTA TOILET O P NT E M OILS E C SP PLA MATERIAL STAGING DUMPSTER 1/2 CRZ 1/4 CRZ 6 X 17 COURTYARD PERGOLA 5' TALL CHAIN-LINK TREE PROTECTION FENCING @ FULL CRZ FRAME COVER & FRAME STRUCTURE W/ WOOD DECK TO BE REMOVED GARAGE STORAGE 5' X 14'-8" POTTING SHED/ DOG WASH 6' X 10'-4" PORTECOCHERE 12 X 21'-5" DOGDOOR GRILL NORTHCOURTYARD 15 X 17 MUD/OFFICE 15'-8" X 8'-6" STAIR OPEN TO ABOVE MUDBATH LAUNDRY 16' X 8'-3" CLOSET ARCH READING NOOK 6'-2" X 15 12 DN PRIMARY CLOSET 12'-10" x 16'-6" LAUNDRY PASS-THRU W/D W/D PRIMARY GALLERY 9'-4" X 6' COFFEE BAR ARCH KNEESPACE @ VANITY PRIMARY BATH 14'-10" X 12'-10" LINEARDRAIN LINEN PRIMARY BEDROOM 18'-10" X 22' VAULTEDCEILING 1/4 CRZ 1/4 CRZ 1/2 CRZ FIREPLACE 8" NATURAL WOOD MULCH 5' TALL CHAIN-LINK TREE PROTECTION FENCING @ FULL CRZ POWDER ROOM 12 12 UP UP BREAKFAST 12'-10" X 13'-3" PANTRY STORAGE 7' X 6'-5" PULL-OUT TRASH FLOWER FLOWER ARRANGING ARRANGING 6'-6" X 11' 6'-6" X 11' REFRIGERATOR FREEZER SCREEN/ DIVIDER SITTING14'-3" X SITTING14'-3" X 19'-2" 48" RANGE W/ 48" VENT HOOD KITCHEN 19'-2" X 15 KITCHEN 19'-2" X 15 PULL-OUT TRASH DW DW STORAGE STORAGE DN 12 DN 12 12 UP UP GALLERY 47'- 4" X 8 1/2 CRZ STAIR UP BARRELVAULT@ HALL FUTURE ELEVATOR DW BUTLER'S PANTRY 9' X 9'-3" PRIMARY TERRACE DN 1/2 CRZ 1/4 CRZ 8" NATURAL WOOD MULCH POOL23' X 12' COLONNADE/PERGOLA W/ BENCH WALL FLANKING EAST EDGE OF GARDEN OR POOL 8" NATURAL WOOD MULCH WATER FEATURE 12 UP ENTRYTERRACE 10'-21 2" DN 12 UP ENTRY21 X11'-1" DN 12 DINING14 X 19 CLOSET BAR DN 12 ENTRYPORCH 18 X 12 DN 12 LIVINGTERRACE DN 12 ENTRYSTAIR PATH TOGARDEN FINISHED SEAT HEIGHT @ 13" A.F.F. LIVING28 X 21 LIVING28 X 21 FIRE PLACE 5' TALL CHAIN-LINK TREE PROTECTION FENCING @ FULL CRZ GUEST PARKING PLANTER I E C N E D S E R Y E L A H D A O R R O S D N W I T S A E 0 2 2 2 3 0 7 8 7 S A X E T , N I T S U A NOT PUBLISHED. ALL RIGHTS RESERVED BY MICHAEL T. LANDRUM, INC. DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF MIICHAEL T. LANDRUM, INC, ISSUED TO DESCRIBED DESIGN INTENT. THEY ARE NOT TO BE USED ON OTHER PROJECTS OR EXTENTIONS TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO TO MICHAEL T. LANDRUM, INC. CONTRACTOR, SUB-CONTRACTORS & SUPPLIERS ARE RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AND CONDITIONS AT JOB SITE, AND SHALL BE RESPONSIBLE FOR ALL LABOR & MATERIALS REQUIRED IN ACCORDANCE WITH DESIGN INTENT. MICHAEL T. LANDRUM, INC. WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE CODES AND ORDINANCES. IN CONNECTION WITH THIS PROJECT. . C N I , M U R D N A L . T L E A H C I M NOTES: TREE PROTECTION FENCING (5-FOOT CHAIN-LINK FENCE) SHOULD BE EXTENDED TO THE FULL AVAILABLE CRITICAL ROOF ZONE (CRZ) OF ALL PROTECTED TREES (19 INCHES OR GREATER IN DIAMETER). ANY CRITICAL ROOF ZONE AND IS NOT PROTECTED BY FENCING. INSTALL TRUNK WRAP (2x4 LUMBER) WHENEVER PROTECTIVE FENCING IS 5 FEET OR LESS FROM THE TRUNK OF THE TREE. TREE PROTECTION FENCING MUST BE CONTINUOUS AND CREATE A CLOSED, INACCESSIBLE AREA OF ROOT ZONE PROTECTION. TRUNK WRAP WILL BE USE TO PROTECT THE TREE IF FENCING IS 5' OR LESS FROM THE TRUNK OF THE TREE. LEGAL DESCRIPTION LOT 22, ENFIELD "D", A SUBDIVISION IN TRAVIS COUNTY, TEXAS, ACCORDING TO THE MAP OR PLAT THEREOF RECORDED IN VOLUME 3 PAGE 158 OF THE PLAT RECORDS OF TRAVIS COUNTY, TEXAS. LOCATED AT 2220 EAST WINDSOR ROAD OWNERS BRIAN AND CAROLINE HALEY 2220 EAST WINDSOR ROAD AUSTIN, TEXAS 78703 t e e r t s s s o r l u s 2 0 5 1 6 0 0 7 7 S A X E T , N O T S U O H - 5 0 6 4 3 2 6 3 1 7 - i m o c . c n m u r d n a l t l e a h c m @ l e a h c m i i REVISIONS 10.07.26 ISSUE FOR PERMIT DATE: 10.07.26 SHEET DESCRIPTION: SHEET DESCRIPTION: ARCHITECTURAL DRAWING ARCHITECTURAL DRAWING TREE PRESERVATION SCALE: 1/16" = 1'-0" SHEET NUMBER: SHEET NUMBER: A 0.02 Copyright Michael T. Landrum, Inc. Copyright Michael T. Landrum, Inc. 2025 2025 5'-0" 4'-6" 6'-6" CRAWL SPACE ACCESS 105 104 ELEVATOR HIDDEN STORAGE HALL 1 103 FUTURE BATH 02/A3.01 2'-0" 2'-111 2" " 12 3 - ' 6 2 5'-0" 11'-0" CEILING POCKET FOR PHANTOM SCREEN STAIR 1 CABANA 14' X 13'-9" F.F. 543.5 " 0 - ' 5 " 0 - ' 7 " 6 4 UP " 9 - ' 2 1 4'-6" 101 01/A3.01 REFRIG ICE UP " 0 - ' 6 102 MECH/STORAGE 1 " 0 - ' 2 " 12 6 - ' 4 " 12 6 - ' 5 " 6 6'-3" " 0 - ' 1 7'-0" 5'-0" 11'-0" 23'-0" POOL 23' X 12' 4'-0" 6'-0" 6'-0" 4'-0" 6'-3" 03/A3.01 106 GRILL 1 107 " 6 - ' 3 I E C N E D S E R Y E L A H D A O R R O S D N W I T S A E 0 2 2 2 3 0 7 8 7 S A X E T , N I T S U A NOT PUBLISHED. ALL RIGHTS RESERVED BY MICHAEL T. LANDRUM, INC. DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF MIICHAEL T. LANDRUM, INC, ISSUED TO DESCRIBED DESIGN INTENT. THEY ARE NOT TO BE USED ON OTHER PROJECTS OR EXTENTIONS TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO TO MICHAEL T. LANDRUM, INC. CONTRACTOR, SUB-CONTRACTORS & SUPPLIERS ARE RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AND CONDITIONS AT JOB SITE, AND SHALL BE RESPONSIBLE FOR ALL LABOR & MATERIALS REQUIRED IN ACCORDANCE WITH DESIGN INTENT. MICHAEL T. LANDRUM, INC. WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE CODES AND ORDINANCES. IN CONNECTION WITH THIS PROJECT. . C N I , M U R D N A L . T L E A H C I M t e e r t s s s o r l u s 2 0 5 1 6 0 0 7 7 S A X E T , N O T S U O H - 5 0 6 4 3 2 6 3 1 7 - i m o c . c n m u r d n a l t l e a h c m @ l e a h c m i i REVISIONS 10.07.26 ISSUE FOR PERMIT DATE: DATE: 10.07.26 SHEET DESCRIPTION: SHEET DESCRIPTION: ARCHITECTURAL DRAWING ARCHITECTURAL DRAWING LOWER LEVEL FLOOR PLAN SCALE: 3/16" = 1'-0" SHEET NUMBER: SHEET NUMBER: A 1.01 Copyright Michael T. Landrum, Inc. Copyright Michael T. Landrum, Inc. 2025 2025 55'-8" 21'-5" 10'-10" 8'-10" 1'-0" 2'-0" 3'-0" 2'-6" 27'-8" 20'-2" 1'-0" 7'-0" 4'-0" 11'-0" 22'-0" 37'-6" 29'-6" 1'-0" 7'-0" 3'-0" 178'-1" " 8 - ' 2 G H " 4 - ' 6 GREENHOUSE WINDOW WINDOW SILL @ 45.75" A.F.F. I F PULL-OUT TRASH REFRIGERATOR FLOWER ARRANGING 6'-6" X 11' FREEZER " 0 - ' 3 " 6 - ' 2 " 6 - ' 6 48" RANGE W/ 48" VENT HOOD KITCHEN " 0 - ' 3 " 0 - ' 3 E " 0 - ' 4 " 0 - ' 4 " 0 - ' 9 PULL-OUT TRASH DW DW " 8 - ' 2 D " 4 - ' 6 WINDOW SILL @ 45.75" A.F.F. C J 8'-10" 2'-0" 1'-0"1'-5" 4'-6" 2'-10" 3'-7" 7'-8" 3'-8" 2'-0" 1'-0" 6'-0" 1'-0" STORAGE " 0 - ' 9 " 12 3 - ' 9 " 12 2 - ' 8 1 55'-8" 52'-8" " 12 2 - ' 5 " 0 - ' 3 " 0 - ' 0 1 6" 5'-101 2" 5'-101 2" 5'-41 2" 3'-10" " 0 - ' 1 " 12 2 - ' 4 " 6 " 12 2 - ' 5 COURTYARD PERGOLA 6 X 17 3'-0" " 0 - ' 4 GRILL 2 " 12 9 - ' 8 F.F. 556.1 NORTH COURTYARD 15 X 17 6'-0" 1 0 . 3 A / 8 1 " 12 3 - ' 5 1 5'-31 2" 1 0 . 3 A / 7 1 5'-31 2" " 12 3 - ' 9 " 0 - ' 1 222 3'-0" " 0 - ' 4 " 0 - ' 7 6'-10" 205 7'-0" " 0 - ' 2 1 SCREEN/ DIVIDER " 12 3 - ' 6 " 0 - ' 5 " 0 - ' 7 " 0 - ' 1 7'-01 2" 223 PANTRY STORAGE 7' X 6'-5" 11/A3.01 1 0 . 3 A / 9 0 1 0 . 3 A / 0 1 BREAKFAST 12'-10" X 13'-3" 15'-41 2" 8'-2" POWDER ROOM " 0 1 - ' 3 2'-0" 2'-6" " 6 " 4 - ' 1 7'-8" " 0 - ' 4 3'-0" 08/A3.01 6'-0" DN 12 1'-0" DN " 0 - ' 3 " 6 - ' 5 " 0 - ' 4 4'-0" BARREL VAULT @ HALL " 6 - ' 2 HALL 2 17'-2" SITTING SITTING 14'-3" X 14'-3" X 19'-2" F.F. 556.2 " 12 3 - ' 9 1 " 12 3 - ' 4 1 " 12 9 - ' 3 " 12 9 - ' 2 4'-0" STAIR 1 " 6 - ' 1 1 12 12 UP UP 13'-91 2" 3'-0" UP 6'-0" 1'-0" 5'-0" 6'-0" FUTURE ELEVATOR 204 06/A3.01 DW BUTLER'S PANTRY 9' X 9'-3" 08/A3.01 1 0 3 A / 7 0 . 11'-0" " 12 1 - ' 3 15'-0" DINING 14 X 19 15'-0" F.F. 555.2 " 0 - ' 0 1 " 12 0 1 - ' 5 " 0 - ' 9 " 6 - ' 3 B " 0 - ' 3 " 5 - ' 7 " 0 - ' 0 1 A " 12 4 - ' 7 " 6 " 0 - ' 8 " 0 - ' 5 2 " 0 - ' 8 POOL 23' X 12' " 0 - ' 8 COLONNADE/PERGOLA W/ BENCH WALL FLANKING EAST EDGE OF GARDEN OR POOL " 6 " 0 - ' 1 " 0 - ' 7 6'-8" 6" 1'-4" 7'-6" 8'-0" 8'-0" 8'-0" 6" 4'-0" 1'-0" 5'-0" 9'-0" 2'-0" 9'-0" 3'-6" 10'-0" 5'-10" 6'-0" 2'-4" 4'-0" 220 221 " 0 - ' 1 " 0 - ' 1 1'-0" 10'-0" 1'-0" K " 5 - ' 1 206 " 12 8 - ' 5 READING NOOK 6'-2" X 15 16'-7" 14'-0" S 14'-0" " 0 - ' 3 1'-8" R " 0 - ' 7 " 8 - ' 4 " 0 - ' 6 " 12 2 - ' 8 Q " 6 - ' 4 GARAGE 21'-5' X 25'-6" 26'-6" F.F. 555.95 16'-2" 219 GARAGE STORAGE 5' X 14'-8" 2 0 . 3 A / 7 1 11'-4" 218 POTTING SHED/ DOG WASH 6' X 10'-4" 2 0 . 3 A / 5 1 2 0 . 3 A / 6 1 " 1 1 - ' 1 2 13'-0" PORTE COCHERE 12 X 21'-5" F.F. 556.1 217 2'-0" 10'-0" 4'-0" 6" 2'-0" Ø4'-0" STAIR 2 STAIR OPEN TO ABOVE 2'-0" " 0 - ' 2 " 6 " 0 - ' 4 " 6 " 1 1 - ' 8 " 0 - ' 6 "99° 5 - ' 5 DOG DOOR 1 " 3'-7 2 1 0 . 3 A / 4 1 MUD/OFFICE 15'-8" X 8'-6" 1 0 . 3 A / 3 1 " 1 1 - ' 8 208 " 0 - ' 1 7'-31 2" " 0 - ' 5 7'-31 " 2 " 6 " 0 - ' 1 209 210 " 0 - ' 7 2'-6" ARCH 207 7'-41 2" " 0 - ' 6 2'-6" 1'-0" 4'-0" 3'-8" T E S O L C " 6 ARCH " 0 - ' 3 " 6 15/A3.01 LAUNDRY 16' X 8'-3" 04/A3.02 MUD BATH 03/A3.02 211 " 6 - ' 7 " 12 0 1 - ' 6 1 02/A3.02 2 0 . 3 A / 1 0 PRIMARY GALLERY 9'-4" X 6' " 12 4 - ' 9 1'-0" 1'-6" 15'-8" " 12 2 3'-0" - ' 1 1 3'-0" 6" " 12 2 - ' 1 1 2 0 . 3 A / 9 0 2 0 . 3 A / 1 1 " 0 - ' 2 " 4 - ' 2 " 6 " 6 - ' 2 LAUNDRY PASS-THRU " 6 - ' 2 W/D " 12 7 - ' 3 W/D COFFEE BAR 10/A3.02 " 12 2 - ' 7 PRIMARY CLOSET 12'-10" x 16'-6" 13'-10" 12/A3.02 " 12 2 - ' 6 4'-6" 7'-31 2" 2'-6" 4'-0" 2'-0" ARCH " 6 1 0 . 3 A / 6 1 " 0 - ' 3 " 6 " 6 212 PRIMARY BEDROOM 18'-10" X 22' VAULTED CEILING 19'-91 2" 05/A3.02 " 0 1 - ' 8 " 12 0 - ' 1 " 3 - ' 2 " 12 0 - ' 1 " 0 1 - ' 9 3'-3" 3'-0" " 4 - ' 3 " 0 - ' 3 13/A3.02 14/A3.02 7'-10" " 6 - ' 2 KNEE SPACE @ VANITY 07/A3.02 10'-4" PRIMARY BATH 14'-10" X 12'-10" 6'-10" 08/A3.02 2'-4" L 216 2'-4" 4'-0" M 2'-4" 4'-0" N " 0 - ' 2 " 6 - ' 2 " 0 1 - ' 6 " 4 - ' 2 " 6 - ' 7 " 9 - ' 3 " 9 - ' 3 " 8 - ' 6 " 5 - ' 0 1 3'-6" 1'-6" 3'-0" 3'-0" 12'-31 " 2 214 " 0 - ' 6 3'-0" 215 213 3'-6" WATER CLOSET 06/A3.02 1'-0" PRIMARY TERRACE DN SHOWER 3'-0" 4'-3" 2'-7" 1'-0" " 8 - ' 4 LINEAR DRAIN LINEN FIREPLACE 1'-63 4" 2'-8" P " 12 0 - ' 2 " 1 1 - ' 4 " 0 - ' 2 " 6 - ' 4 " 12 0 - ' 3 " 0 - ' 6 " 3 - ' 1 0 1 " 1 1 - ' 9 2 " 5 - ' 2 2 " 6 - ' 7 2 0 . 3 A / 8 1 2 0 . 3 A / 8 1 " 12 0 1 - ' 2 3 " 12 1 1 - ' 1 " 0 - ' 1 12 12 " 0 - ' 1 UP UP 6'-0" " 0 - ' 9 " 0 - ' 1 " 12 1 - ' 5 " 0 - ' 8 6'-0" " 0 - ' 1 " 0 - ' 1 12 DN " 12 1 - ' 2 1 7'-0" 1'-0" " 0 - ' 7 9'-31 " 2 9'-31 2" 1 0 . 3 A / 2 1 51'-61 " 2 6'-111 2" 3'-111 2" " 0 - ' 9 GALLERY 47'- 4" X 8 35'-4" T U V 6'-5" 4" 6'-5" 4" 6'-5" 4" W 6'-5" " 12 1 - ' 6 " 12 1 - ' 3 1 " 12 1 - ' 3 1 " 0 - ' 6 " 0 - ' 0 1 " 0 - ' 6 1 " 0 1 - ' 5 " 0 - ' 7 1 26'-7" " 12 0 1 - ' 9 3 " 0 - ' 6 " 0 - ' 1 " 0 - ' 8 " 0 - ' 1 X 4" 6'-5" WATER FEATURE ENTRY TERRACE DN 1'-0" CEILING HT TRANSITION @ GALLERY " 0 - ' 9 14'-0" " 0 - ' 1 12 UP 7'-0" " 6 " 6 12 UP 1'-0" " 6 - ' 2 CLOSET 7'-0" 7'-0" 1'-6" 05/A3.01 " 12 1 - ' 1 1 22'-0" ENTRY 21 X11'-1" 202 F.F. 554.2 15'-0" DN " 0 12 - ' 1 201 7'-0" 1'-6" BAR 04/A3.01 " 1 1 - ' 3 1 1'-0" 5'-9" 6'-9" " 8 2'-2" 3'-2" 2'-6" LIVING 28 X 21 F.F. 553.2 FINISHED SEAT HEIGHT @ 13" A.F.F. CANTILEVERED WINDOW BAY 2'-6" 2'-3" 1'-8" 4'-6" 1'-8" " 2 - ' 1 FIRE PLACE " 8 - ' 6 2 " 2 - ' 1 203 1'-6" Y " 9 - ' 2 1 " 5 - ' 1 1 " 8 " 2 - ' 3 " 2 - ' 5 " 0 - ' 1 " 0 - ' 1 " 12 1 - ' 5 " 0 - ' 6 " 12 1 - ' 1 1 7'-0" DN 12 " 7 - ' 4 1 " 5 - ' 1 1 " 0 1 - ' 2 " 0 - ' 1 " 0 - ' 2 2'-2" 11'-1" 12'-5" 21'-6" " 0 - ' 1 " 12 1 - ' 1 1 ENTRY PORCH 18 X 12 F.F. 554.075 1'-0" 7'-0" DN 12 1'-0" " 0 - ' 1 7'-0" DN 12 1'-0" 5'-0" 2'-0" 1'-0" " 6 " 12 1 - ' 2 1 " 6 " 0 - ' 7 LIVING TERRACE F.F. 553.075 ENTRY STAIR PATH TO GARDEN " 1 1 - ' 4 " 0 1 - ' 7 2 " 0 - ' 1 1 " 0 - ' 5 " 0 - ' 1 " 0 - ' 6 " 1 1 - ' 4 " 0 - ' 6 1'-6" 5'-0" 6'-0" 3'-0" " 0 - ' 1 " 0 - ' 1 1'-0" " 0 - ' 8 7'-6" 1'-0" " 0 - ' 6 " 0 - ' 4 " 0 - ' 1 PLANTER " 0 - ' 6 " 0 - ' 1 9'-0" " 0 - ' 1 1 " 0 - ' 8 O 10'-91 2" 5'-0" 1'-8" 8'-3" 5'-7" 2'-0" 2'-6" 18'-4" 15'-91 2" 22'-2" 34'-11 2" 58'-31 2" 177'-1" 62'-6" " 12 3 - ' 8 " 12 8 " 3 - ' 2 7 " 3 - ' 1 0 1 I E C N E D S E R Y E L A H D A O R R O S D N W I T S A E 0 2 2 2 3 0 7 8 7 S A X E T , N I T S U A NOT PUBLISHED. ALL RIGHTS RESERVED BY MICHAEL T. LANDRUM, INC. DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF MIICHAEL T. LANDRUM, INC, ISSUED TO DESCRIBED DESIGN INTENT. THEY ARE NOT TO BE USED ON OTHER PROJECTS OR EXTENTIONS TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO TO MICHAEL T. LANDRUM, INC. CONTRACTOR, SUB-CONTRACTORS & SUPPLIERS ARE RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AND CONDITIONS AT JOB SITE, AND SHALL BE RESPONSIBLE FOR ALL LABOR & MATERIALS REQUIRED IN ACCORDANCE WITH DESIGN INTENT. MICHAEL T. LANDRUM, INC. WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE CODES AND ORDINANCES. IN CONNECTION WITH THIS PROJECT. . C N I , M U R D N A L . T L E A H C I M t e e r t s s s o r l u s 2 0 5 1 6 0 0 7 7 S A X E T , N O T S U O H - 5 0 6 4 3 2 6 3 1 7 - i m o c . c n m u r d n a l t l e a h c m @ l e a h c m i i REVISIONS 10.07.26 ISSUE FOR PERMIT DATE: 10.07.26 SHEET DESCRIPTION: SHEET DESCRIPTION: ARCHITECTURAL DRAWING ARCHITECTURAL DRAWING FIRST FLOOR PLAN SCALE: 3/16" = 1'-0" SHEET NUMBER: SHEET NUMBER: A 1.02 Copyright Michael T. Landrum, Inc. Copyright Michael T. Landrum, Inc. 2025 2025 " 0 - ' 9 " 0 1 - ' 7 " 0 1 - ' 4 4 " 6 - ' 4 1 " 12 1 1 - ' 8 " 12 6 - ' 4 " 6 " 0 - ' 1 " 5 - ' 0 3 " 0 1 - ' 3 " 3 - ' 6 " 0 1 - ' 3 " 3 - ' 9 " 9 - ' 5 6" 5'-71 2" 6'-3" Z16 5'-11 2" 3'-1" 2'-6" 3'-11" 3'-101 2" 3'-41 2" 6'-3" Z14 " 0 - ' 4 " 0 - ' 6 " 9 - ' 5 GUEST BEDROOM 15' X 15'-6" 16'-6" 324 Z15 323 2 0 . 3 A / 0 2 GUEST BATH 8'-6" X 9' 322 321 9'-6" 19/A3.02 320 GUEST CLOSET 5'-6" X 9' " 6 " 6 6" 3'-3" 11'-0" 7'-5" GUEST TERRACE 21' X 11'-8" 10" 4'-0" " 2 - ' 3 " 6 - ' 2 " 6 " 12 0 1 - ' 1 " 0 - ' 3 Z17 " 0 - ' 7 " 0 - ' 3 Z18 " 5 - ' 0 3 " 12 0 1 - ' 1 " 8 - ' 2 1 " 6 " 7 - ' 0 1 3 0 . 3 A / 0 2 STUDY 13' X 14' Z13 1'-6" " 4 - ' 3 4'-0" 2'-6" 6'-0" REFRIG DRWR 319 MECH/ STORAGE 3 2 0 . 3 A / 1 2 " 0 - ' 6 318 GUEST ENTRY " 6 - ' 2 STAIR OPEN TO BELOW " 0 - ' 2 2'-6" 9'-11 2" STAIR 2 " 6 " 0 - ' 4 " 0 - ' 1 23'-2" 6'-4" 7'-5" 3'-7" STANDING SEAM COPPER ROOF - SLOPE TO DARIN TO INTERIOR PERIMETER GUTTER SYSTEM & THRU WALL SCUPPERS (ALTERNATE PRICING - PAINT GRIP FINISH) 10'-10" 27'-8" 22'-0" 1'-4" 61'-10" 3'-9" 2'-6" 2'-9" 3'-0" 6'-0" 3'-0" 2'-0" 4'-8" Z8 Z7 Z6 " 12 0 - ' 4 " 12 1 1 - ' 4 3'-3" 2'-6" Z9 . 3 0 3 A / 1 0 . 3 0 3 A / 2 0 BATH 2 316 10'-0" 2'-0" 4'-6" 4'-3" 10" 4'-6" 3'-0" BATH 1 . 3 0 3 A / 5 0 " 6 - ' 5 06/A3.03 317 " 4 - ' 2 1 15'-0" BEDROOM 1 15 X 14'-6" " 6 - ' 5 1 " 12 9 - ' 2 04/A3.03 CLOSET 2 . 3 0 3 A / 3 0 315 5'-0" 5'-0" 314 LINEN 311 4'-6" " 2 - ' 3 " 0 1 - ' 2 07/A3.03 CLOSET 1 9'-6" HALL 3 22 X 4' 312 " 0 1 - ' 2 " 0 - ' 5 BEDROOM 2 13 X 14 313 5'-3" " 0 - ' 3 11'-0" . 3 0 3 A / 8 0 STOR. 310 4'-10" WINDOW SEAT . " 0 - ' 0 1 3 0 3 A / 9 0 5'-2" 10/A3.03 " 9 - ' 3 " 0 - ' 3 2'-6" Z4 2'-9" " 3 - ' 2 4'-6" 4'-6" 6'-0" Z5 1'-9" 309 " 4 - ' 4 3'-8" 1'-0" LANDING 6'-0" DN " 4 - ' 5 " 6 - ' 5 1'-0" 4'-0" ELEVATOR 301 STORAGE 2 12/A3.03 303 . 3 0 3 A / 1 1 HALL 4 " 8 - ' 6 " 6 - ' 6 302 LAUNDRY 14/A3.03 . 3 0 3 A / 3 1 W/D BROOM 10'-6" Z3 " 0 - ' 3'-8" 9 5'-3" " 6 - ' 3 STAIR 1 304 5'-6" " 0 1 - ' 9 Z10 2'-6" 2'-3" 6'-11 2" Z11 4'-11 2" 6" 6" " 6 - ' 4 " 6 " 12 1 1 - ' 7 " 0 - ' 1 37'-6" BALCONY TERRACE 21'-6" " " 0 0 - - ' ' 3 3 Z12 7'-0" " 4 - ' 4 1 BEDROOM 3 14 X 16'-6" " 12 5 - ' 0 1 " 12 6 - ' 4 306 MECH/ STORAGE 2 6'-2" " 6 - ' 4 305 3 0 . 3 A / 6 1 " 0 - ' 6 CLOSET 3 17/A3.03 " 6 - ' 3 7'-6" 6'-0" 23'-0" 9'-10" 307 3 0 . 3 A / 8 1 BATH 3 308 3 0 . 3 A / 9 1 9'-6" MINIMAL SLOPE SINGLE PLY MEMBRANE ROOF - SLOPE TO DRAIN TO INTERIOR GUTTER & THRU-WALL SCUPPERS 3 0 . 3 A / 5 1 3'-0" 1'-0"1'-0" Z2 1'-0"4" Z1 Z " 0 1 - ' 4 4 " 6 - ' 5 " 6 - ' 6 " 7 - ' 2 " 0 - ' 9 " 7 - ' 4 1 " 8 - ' 8 " 7 - ' 2 " 0 - ' 2 " 6 - ' 2 " 0 - ' 2 " 6 - ' 3 I E C N E D S E R Y E L A H D A O R R O S D N W I T S A E 0 2 2 2 3 0 7 8 7 S A X E T , N I T S U A NOT PUBLISHED. ALL RIGHTS RESERVED BY MICHAEL T. LANDRUM, INC. DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF MIICHAEL T. LANDRUM, INC, ISSUED TO DESCRIBED DESIGN INTENT. THEY ARE NOT TO BE USED ON OTHER PROJECTS OR EXTENTIONS TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO TO MICHAEL T. LANDRUM, INC. CONTRACTOR, SUB-CONTRACTORS & SUPPLIERS ARE RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AND CONDITIONS AT JOB SITE, AND SHALL BE RESPONSIBLE FOR ALL LABOR & MATERIALS REQUIRED IN ACCORDANCE WITH DESIGN INTENT. MICHAEL T. LANDRUM, INC. WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE CODES AND ORDINANCES. IN CONNECTION WITH THIS PROJECT. . C N I , M U R D N A L . T L E A H C I M t e e r t s s s o r l u s 2 0 5 1 6 0 0 7 7 S A X E T , N O T S U O H - 5 0 6 4 3 2 6 3 1 7 - i m o c . c n m u r d n a l t l e a h c m @ l e a h c m i i REVISIONS 10.07.26 ISSUE FOR PERMIT DATE: 10.07.26 SHEET DESCRIPTION: SHEET DESCRIPTION: ARCHITECTURAL DRAWING ARCHITECTURAL DRAWING SECOND FLOOR PLAN SCALE: 3/16" = 1'-0" SHEET NUMBER: SHEET NUMBER: A 1.03 Copyright Michael T. Landrum, Inc. Copyright Michael T. Landrum, Inc. 2025 2025 CHIMNEY STAIR OPEN TO BELOW STANDING SEAM COPPER ROOF - SLOPE TO DARIN TO INTERIOR PERIMETER GUTTER SYSTEM & THRU WALL SCUPPERS (ALTERNATE PRICING - PAINT GRIP FINISH) OPEN TO BELOW MINIMAL SLOPE SINGLE PLY MEMBRANE ROOF - SLOPE TO DRAIN TO INTERIOR GUTTER & THRU-WALL SCUPPERS Y E N M H C I CHIMNEY I E C N E D S E R Y E L A H D A O R R O S D N W I T S A E 0 2 2 2 3 0 7 8 7 S A X E T , N I T S U A NOT PUBLISHED. ALL RIGHTS RESERVED BY MICHAEL T. LANDRUM, INC. DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF MIICHAEL T. LANDRUM, INC, ISSUED TO DESCRIBED DESIGN INTENT. THEY ARE NOT TO BE USED ON OTHER PROJECTS OR EXTENTIONS TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO TO MICHAEL T. LANDRUM, INC. CONTRACTOR, SUB-CONTRACTORS & SUPPLIERS ARE RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AND CONDITIONS AT JOB SITE, AND SHALL BE RESPONSIBLE FOR ALL LABOR & MATERIALS REQUIRED IN ACCORDANCE WITH DESIGN INTENT. MICHAEL T. LANDRUM, INC. WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE CODES AND ORDINANCES. IN CONNECTION WITH THIS PROJECT. . C N I , M U R D N A L . T L E A H C I M t e e r t s s s o r l u s 2 0 5 1 6 0 0 7 7 S A X E T , N O T S U O H - 5 0 6 4 3 2 6 3 1 7 - i m o c . c n m u r d n a l t l e a h c m @ l e a h c m i i REVISIONS 10.07.26 ISSUE FOR PERMIT DATE: 10.07.26 SHEET DESCRIPTION: SHEET DESCRIPTION: ARCHITECTURAL DRAWING ARCHITECTURAL DRAWING ROOF PLAN SCALE: 3/16" = 1'-0" SHEET NUMBER: SHEET NUMBER: A 1.04 Copyright Michael T. Landrum, Inc. Copyright Michael T. Landrum, Inc. 2025 2025 324 Z10 Z11 312 " 0 - ' 0 1 N " 0 - ' 0 1 O 213 " 0 - ' 2 1 S " 0 - ' 0 1 " 8 - ' 1 " 0 - ' 1 1 T U V W X CANTILEVERED WINDOW BAY " 0 - ' 4 1 " 0 - ' 8 3'-0" 1'-6" Z1 " 0 - ' 5 " 0 - ' 4 " 0 - ' 1 1'-4" OPEN OPEN OPEN 3'-0" " 0 - ' 3 " 6 - ' 3 Z3 Z4 Z6 Z7 Z8 Z9 Z14 Z15 Z16 " 0 - ' 9 " 8 - ' 2 Z C 1'-6" " 0 - ' 5 " 0 - ' 3 " 0 - ' 1 Z2 A OPEN OPEN OPEN OPEN " 6 - ' 3 107 106 " 0 - ' 4 1 203 201 " 8 - ' 1 E " 34 9 - ' 3 " 0 - ' 9 " 8 - ' 1 " 8 - ' 3 3 " 0 - ' 0 1 F G I " 34 9 - ' 3 I ) T H G E H G N D L U B ( I I OPEN OPEN OPEN K " 0 - ' 3 STAIR OPEN TO ABOVE (556.1) 221 220 METAL CLAD GARAGE DRS (TO MATCH ROOF) METAL CLAD GARAGE DRS (TO MATCH ROOF) (AVERAGE NATURAL GRADE 548.25) " 0 - ' 9 " 0 - ' 2 " 0 - ' 9 " 0 - ' 5 3 ) H ' 5 3 X A M ( Z5 B D " 34 9 - ' 3 " 0 - ' 9 " 8 - ' 1 " 0 - ' 0 1 " 8 - ' 3 " 0 - ' 9 " 0 - ' 4 1 203 201 Z 1'-6" " 0 - ' 5 " 0 - ' 3 " 0 - ' 1 Z2 A OPEN TO CABANA " 0 - ' 9 " 4 Z5 B D " 0 - ' 9 " 8 - ' 1 " 0 - ' 0 1 " 8 - ' 3 " 0 - ' 9 I E C N E D S E R Y E L A H D A O R R O S D N W I T S A E 0 2 2 2 3 0 7 8 7 S A X E T , N I T S U A NOT PUBLISHED. ALL RIGHTS RESERVED BY MICHAEL T. LANDRUM, INC. DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF MIICHAEL T. LANDRUM, INC, ISSUED TO DESCRIBED DESIGN INTENT. THEY ARE NOT TO BE USED ON OTHER PROJECTS OR EXTENTIONS TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO TO MICHAEL T. LANDRUM, INC. CONTRACTOR, SUB-CONTRACTORS & SUPPLIERS ARE RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AND CONDITIONS AT JOB SITE, AND SHALL BE RESPONSIBLE FOR ALL LABOR & MATERIALS REQUIRED IN ACCORDANCE WITH DESIGN INTENT. MICHAEL T. LANDRUM, INC. WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE CODES AND ORDINANCES. IN CONNECTION WITH THIS PROJECT. . C N I , M U R D N A L . T L E A H C I M t e e r t s s s o r l u s 2 0 5 1 6 0 0 7 7 S A X E T , N O T S U O H - 5 0 6 4 3 2 6 3 1 7 - i m o c . c n m u r d n a l t l e a h c m @ l e a h c m i i REVISIONS 10.07.26 ISSUE FOR PERMIT DATE: 10.07.26 SHEET DESCRIPTION: SHEET DESCRIPTION: ARCHITECTURAL DRAWING ARCHITECTURAL DRAWING EXTERIOR ELEVATION SCALE: 3/16" = 1'-0" SHEET NUMBER: SHEET NUMBER: A 2.01 Copyright Michael T. Landrum, Inc. Copyright Michael T. Landrum, Inc. 2025 2025 I E C N E D S E R Y E L A H D A O R R O S D N W I T S A E 0 2 2 2 3 0 7 8 7 S A X E T , N I T S U A NOT PUBLISHED. ALL RIGHTS RESERVED BY MICHAEL T. LANDRUM, INC. DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF MIICHAEL T. LANDRUM, INC, ISSUED TO DESCRIBED DESIGN INTENT. THEY ARE NOT TO BE USED ON OTHER PROJECTS OR EXTENTIONS TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO TO MICHAEL T. LANDRUM, INC. CONTRACTOR, SUB-CONTRACTORS & SUPPLIERS ARE RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AND CONDITIONS AT JOB SITE, AND SHALL BE RESPONSIBLE FOR ALL LABOR & MATERIALS REQUIRED IN ACCORDANCE WITH DESIGN INTENT. MICHAEL T. LANDRUM, INC. WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE CODES AND ORDINANCES. IN CONNECTION WITH THIS PROJECT. " 8 - ' 1 4" 6'-0" " 14 2 - ' 4 " 4 " 34 9 - ' 3 H J 205 " 8 - ' 6 " 0 - ' 3 Z17 Z18 318 " 0 - ' 9 " 0 - ' 2 " 0 - ' 9 M " 0 - ' 0 1 " 0 - ' 0 1 " 0 - ' 1 1 P Q R Z13 313 " 7 - ' 3 " 0 - ' 1 1 " 6 " 6 " 0 - ' 9 " 8 - ' 1 " 0 - ' 0 1 Z12 " 0 - ' 9 " 8 - ' 1 202 " 0 - ' 1 1 CANTILEVERED WINDOW BAY Y " 0 - ' 3 1 " 0 - ' 4 1 " 0 - ' 1 1 " 1 - ' 1 " 0 - ' 2 " 0 - ' 8 " 4 - ' 6 " 0 - ' 9 " 8 - ' 2 " 0 - ' 0 1 " 8 - ' 2 " 0 - ' 9 " 8 - ' 1 " 0 - ' 9 " 8 - ' 1 " 0 - ' 0 1 Z2 D " 0 - ' 3 26'-10" 206 " 0 - ' 0 1 " 0 - ' 1 " 12 7 - ' 7 " 6 - ' 3 " 12 8 - ' 1 " 6 - ' 8 " 12 1 - ' 1 1 " 6 - ' 1 " 6 - ' 1 " 12 7 1'-0" 12'-11 2" Z12 " 0 - ' 9 " 0 - ' 8 " 0 - ' 1 1 202 " 0 - ' 1 1 Y " 0 - ' 3 1 CANTILEVERED WINDOW BAY . C N I , M U R D N A L . T L E A H C I M t e e r t s s s o r l u s 2 0 5 1 6 0 0 7 7 S A X E T , N O T S U O H - 5 0 6 4 3 2 6 3 1 7 - i m o c . c n m u r d n a l t l e a h c m @ l e a h c m i i REVISIONS 10.07.26 ISSUE FOR PERMIT DATE: 10.07.26 SHEET DESCRIPTION: SHEET DESCRIPTION: ARCHITECTURAL DRAWING ARCHITECTURAL DRAWING EXTERIOR ELEVATION SCALE: 3/16" = 1'-0" SHEET NUMBER: SHEET NUMBER: A 2.02 Copyright Michael T. Landrum, Inc. Copyright Michael T. Landrum, Inc. 2025 2025 " 2 - ' 2 N " 0 - ' 8 " 0 - ' 2 1 212 " 0 - ' 0 1 " 0 - ' 8 R1'-0" 206 " 0 - ' 1 1 203 201 Z5 B D Z " 0 - ' 3 3'-0" Z2 A OPEN TO CABANA I E C N E D S E R Y E L A H D A O R R O S D N W I T S A E 0 2 2 2 3 0 7 8 7 S A X E T , N I T S U A NOT PUBLISHED. ALL RIGHTS RESERVED BY MICHAEL T. LANDRUM, INC. DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF MIICHAEL T. LANDRUM, INC, ISSUED TO DESCRIBED DESIGN INTENT. THEY ARE NOT TO BE USED ON OTHER PROJECTS OR EXTENTIONS TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO TO MICHAEL T. LANDRUM, INC. CONTRACTOR, SUB-CONTRACTORS & SUPPLIERS ARE RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AND CONDITIONS AT JOB SITE, AND SHALL BE RESPONSIBLE FOR ALL LABOR & MATERIALS REQUIRED IN ACCORDANCE WITH DESIGN INTENT. MICHAEL T. LANDRUM, INC. WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE CODES AND ORDINANCES. IN CONNECTION WITH THIS PROJECT. . C N I , M U R D N A L . T L E A H C I M t e e r t s s s o r l u s 2 0 5 1 6 0 0 7 7 S A X E T , N O T S U O H - 5 0 6 4 3 2 6 3 1 7 - i m o c . c n m u r d n a l t l e a h c m @ l e a h c m i i REVISIONS 10.07.26 ISSUE FOR PERMIT DATE: 10.07.26 SHEET DESCRIPTION: SHEET DESCRIPTION: ARCHITECTURAL DRAWING ARCHITECTURAL DRAWING BUILDING SECTION SCALE: 3/16" = 1'-0" SHEET NUMBER: SHEET NUMBER: A 2.03 Copyright Michael T. Landrum, Inc. Copyright Michael T. Landrum, Inc. 2025 2025 " 0 - ' 9 " 6 - ' 4 " 6 - ' 1 " 0 - ' 3 STAINED WOOD CABINETRY W/ SLAB STONE COUNTER & FULL HT TILE SPLASH ICE MAKER REFRIGERATOR DRWRS 1'-0" 3'-0" 1'-6" 2'-0" 3'-0" 4'-6" FULL HT MIRROR " 0 - ' 9 FULL HT TILE @ SHOWER NOTE: DROP FF @ SHOWER 4" BELOW ADJAC. BATHROOM FF 42" H. TILE WAINSCOT @ BATHROOM WALLS (TYP) SLAB STONE W/ 4" H. STONE SPLASH " 0 - ' 3 " 4 FULL HT TILE SURROUND (ALTERNATE: STUCCO FINISH) GAS GRILL STAINLESS STEEL CABINETRY (ALTERNATE: INTEGRAL PIGMENT CONCRETE W/ SS CBNT FRONTS) " 0 - ' 1 1 OPEN TO GALLERY OPEN TO ENTRY HALL & DINING BEYOND " 6 - ' 4 " 6 - ' 1 " 0 - ' 3 FREESTANDING BRONZE BAR BRONZE OPEN SHELVING BRONZE CABINETRY ICE MAKER 3'-4" 1'-4" 1'-4" 3'-6" 4'-0" 10'-0" 4'-0" 14'-0" 6'-8" 4" POOL CABANA - SOUTH 1 POOL BATH - SOUTH 2 POOL GRILL - SOUTH 3 LIVING - NORTH 4 R1'-0" " 0 - ' 1 1 " 0 - ' 0 1 OPEN TO GALLERY OPEN TO DINING & BUTLER'S PANTRY HALL BEYOND FREESTANDINGBRONZE CLAD WARDROBE " 0 - ' 8 14'-0" 6'-8" 4" ENTRY - NORTH 5 " 6 - ' 5 " 6 - ' 1 " 0 - ' 3 " 12 1 - ' 1 " 12 1 - ' 1 " " 3 12 1 - - ' 1 ' 1 " 0 - ' 2 OPEN TO DINING DISHWASHER " 6 - ' 5 " 6 - ' 1 " 0 - ' 3 " 0 - ' 0 1 " 0 - ' 8 " 6 - ' 5 " 6 - ' 1 " 0 - ' 3 2'-0" 2" 2'-41 2'-6" 2" 2'-11 1'-0" 4'-0" 2'-0" 2" 5'-31 2'-0" 1'-3" 6'-0" 1'-0" 4'-0" 5'-0" 3'-0" 2'-0" BUTLER'S PANTRY - SOUTH 6 BUTLER'S PANTRY - EAST 7 BUTLER'S PANTRY/HALL/STORAGE - NORTH 8 FULL HEIGHT MIRROR SLAB STONE W/ 4" H. STONE SPLASH " 0 - ' 3 42" H. TILE WAINSCOT @ BATHROOM WALLS (TYP) 4" 1'-43 " 12 1 - ' 1 " 12 1 - ' 1 " 12 1 - ' 1 " 3 - ' 1 " 0 - ' 2 1'-8" 5'-4" 5'-4" 1'-8" 1'-8" 3'-1" 1'-8" 3'-10" 4" 1'-91 PANTRY - WEST 9 PANTRY - EAST 10 PANTRY - SOUTH 11 POWDER - EAST 12 2" 8'-41 " 0 - ' 0 1 " 0 - ' 5 " 0 - ' 2 " 0 - ' 3 OPEN TO PRIMARY GALLERY OPEN TO PRIMARY GALLERY " 0 - ' 9 " 0 - ' 9 " 0 - ' 8 COFFEE BAR " 6 - ' 3 " 6 - ' 1 " 0 - ' 3 " 0 - ' 3 " 0 - ' 4 " 4 - ' 1 " 0 - ' 8 FULL HT TILE SURROUND (ALTERNATE: STUCCO FINISH) GAS GRILL STAINLESS STEEL CABINETRY (ALTERNATE: INTEGRAL PIGMENT CONCRETE W/ SS CBNT FRONTS) " 6 - ' 3 " 0 - ' 3 2" 2'-11 2" 4'-11 2" 2'-11 2" 8'-41 1'-0" 4'-0" 1'-0" 6" 3'-0" 6" 1'-0" 2" 4'-21 1'-0" 4'-11" 5'-0" 4'-11" 3'-0" 4" 4'-43 4" 4'-43 4'-0" 2" 4'-21 1'-0" OFFICE - EAST 13 OFFICE - WEST 14 PRIMARY HALL - NORTH 15 PRIMARY HALL - WEST 16 COURTYARD - EAST 17 COURTYARD - WEST 18 " 12 1 - ' 1 " 12 1 - ' 1 " 12 1 - ' 1 " 3 - ' 1 " 0 - ' 2 " 6 - ' 5 " 0 - ' 2 " 6 - ' 2 I E C N E D S E R Y E L A H D A O R R O S D N W I T S A E 0 2 2 2 3 0 7 8 7 S A X E T , N I T S U A NOT PUBLISHED. ALL RIGHTS RESERVED BY MICHAEL T. LANDRUM, INC. DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF MIICHAEL T. LANDRUM, INC, ISSUED TO DESCRIBED DESIGN INTENT. THEY ARE NOT TO BE USED ON OTHER PROJECTS OR EXTENTIONS TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO TO MICHAEL T. LANDRUM, INC. CONTRACTOR, SUB-CONTRACTORS & SUPPLIERS ARE RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AND CONDITIONS AT JOB SITE, AND SHALL BE RESPONSIBLE FOR ALL LABOR & MATERIALS REQUIRED IN ACCORDANCE WITH DESIGN INTENT. MICHAEL T. LANDRUM, INC. WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE CODES AND ORDINANCES. IN CONNECTION WITH THIS PROJECT. . C N I , M U R D N A L . T L E A H C I M t e e r t s s s o r l u s 2 0 5 1 6 0 0 7 7 S A X E T , N O T S U O H - 5 0 6 4 3 2 6 3 1 7 - i m o c . c n m u r d n a l t l e a h c m @ l e a h c m i i REVISIONS 10.07.26 ISSUE FOR PERMIT DATE: 10.07.26 SHEET DESCRIPTION: SHEET DESCRIPTION: ARCHITECTURAL DRAWING ARCHITECTURAL DRAWING INTERIOR ELEVATION SCALE: 1/2" = 1'-0" SHEET NUMBER: SHEET NUMBER: A 3.01 Copyright Michael T. Landrum, Inc. Copyright Michael T. Landrum, Inc. 2025 2025 " 0 - ' 0 1 UTILITY CLOSET HANGING ROD WASHER/DRYER " 0 - ' 2 " 12 3 - ' 3 " 14 7 - ' 3 " 12 3 - ' 3 PASS-THRU TO PRIMARY CLOSET PRIMARY CLOSET FULL HT MIRROR SLAB STONE W/ 4" H. STONE SPLASH " 0 - ' 7 " 0 - ' 3 42" H. TILE WAINSCOT @ BATHROOM WALLS (TYP) " 6 - ' 4 42" H. TILE WAINSCOT @ BATHROOM WALLS (TYP) " 6 - ' 4 4'-6" 2" 5'-31 4'-1" 2" 2'-11 1'-0" 2" 5'-51 10" 4'-6" 3'-6" 3'-6" 2" 14'-31 4'-6" 3'-0" LAUNDRY - EAST 1 LAUNDRY - SOUTH 2 LAUNDRY TOILET - SOUTH 3 LAUNDRY TOILET - NORTH 4 PRIMARY BEDROOM - SOUTH 5 PRIMARY TOILET - NORTH 6 " 0 - ' 9 OPEN TO CLOSET " 0 - ' 0 1 " 0 - ' 0 1 OPEN TO TOILET VESTIBULE OPEN TO SHOWER " 0 - ' 0 1 " 0 - ' 9 2R2S 2R2S " 0 - ' 0 1 2R2S 2R2S FULL HEIGHT MIRROR @ WALL FULL HEIGHT MIRROR @ WALL TUB AREA 3'-0" 3'-0" " 0 - ' 3 6" 7 VANITY BY OWNER " 0 - ' 3 TUB AREA 5'-10" 3'-6" 3'-0" 6" 5'-10" 6" 3'-0" 3'-0" 5'-0" 11'-6" 2'-0" 8'-10" 2'-0" PRIMARY BATH - NORTH PRIMARY BATH - SOUTH 8 PRIMARY CLOSET -WEST 9 PRIMARY CLOSET = NORTH 10 1R2S 1R2S " 0 - ' 0 1 OPEN ADJUS SHELVING OPEN TO PRIMARY BATH " 0 - ' 0 1 " 0 - ' 0 1 OPEN TO PRIMARY CLOSET OPEN ADJUS SHELVING 2R2S 2R2S OPEN TO PRIMARY BATH " 0 - ' 0 1 " 3 - ' 2 " 9 - ' 3 " 0 - ' 3 6'-0" " 6 - ' 1 " 4 " 0 - ' 2 " 6 - ' 2 " 6 - ' 1 " 0 - ' 3 2'-0" 2" 5'-21 4'-4" 3'-0" 2'-0" 2'-0" 5'-6" 4" 3'-0" 2'-0" 2'-0" 3'-0" 4" 5'-6" 2'-0" 2'-0" 7'-4" 4" 3'-2" 6" 4'-0" 1'-6" PRIMARY CLOSET - EAST 11 PRIMARY CLOSET - SOUTH 12 HIS PRIMARY CLOSET - NORTH 13 HIS PRIMARY CLOSET - SOUTH 14 POTTING SHED/DOG WASH - WEST 15 " 0 - ' 2 " 0 - ' 7 " 0 - ' 6 " 0 - ' 3 OPEN SHELVING " 0 - ' 2 " 0 - ' 3 KNEE SPACE @ WORK BENCH 2R2S 2R2S " 0 - ' 4 " 0 - ' 5 FULL HT MIRROR SLAB STONE W/ 4" H. STONE SPLASH " 0 - ' 9 " 8 - ' 5 " 4 " 0 - ' 3 I E C N E D S E R Y E L A H D A O R R O S D N W I T S A E 0 2 2 2 3 0 7 8 7 S A X E T , N I T S U A NOT PUBLISHED. ALL RIGHTS RESERVED BY MICHAEL T. LANDRUM, INC. DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF MIICHAEL T. LANDRUM, INC, ISSUED TO DESCRIBED DESIGN INTENT. THEY ARE NOT TO BE USED ON OTHER PROJECTS OR EXTENTIONS TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO TO MICHAEL T. LANDRUM, INC. CONTRACTOR, SUB-CONTRACTORS & SUPPLIERS ARE RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AND CONDITIONS AT JOB SITE, AND SHALL BE RESPONSIBLE FOR ALL LABOR & MATERIALS REQUIRED IN ACCORDANCE WITH DESIGN INTENT. MICHAEL T. LANDRUM, INC. WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE CODES AND ORDINANCES. IN CONNECTION WITH THIS PROJECT. . C N I , M U R D N A L . T L E A H C I M " 6 - ' 4 " 6 - ' 1 " 0 - ' 3 t e e r t s s s o r l u s 2 0 5 1 6 0 0 7 7 S A X E T , N O T S U O H - 5 0 6 4 3 2 6 3 1 7 - i m o c . c n m u r d n a l t l e a h c m @ l e a h c m i i 6'-0" 6'-0" 6'-0" 6" 6'-0" 3'-0" 3'-5" 3'-0" 6'-0" 9'-0" 5'-6" 6" 3'-0" 6" 4" 2'-03 4" 2'-51 GUEST CLOSET - SOUTH 19 GUEST BATH - WEST 20 GUEST ENTRY - EAST 21 REVISIONS 10.07.26 ISSUE FOR PERMIT POTTING SHED/DOG WASH - EAST 16 GARAGE STORAGE - EAST 17 GARAGE/ GARAGE STORAGE - WEST 18 DATE: 10.07.26 SHEET DESCRIPTION: SHEET DESCRIPTION: ARCHITECTURAL DRAWING ARCHITECTURAL DRAWING INTERIOR ELEVATION SCALE: 1/2" = 1'-0" SHEET NUMBER: SHEET NUMBER: A 3.02 Copyright Michael T. Landrum, Inc. Copyright Michael T. Landrum, Inc. 2025 2025 2" 6'-91 2" 6'-91 2" 6'-91 2" 5'-01 8'-6" FULL HT MIRROR SLAB STONE W/ 4" H. STONE SPLASH " 0 - ' 9 " 0 - ' 6 " 0 - ' 3 " 0 - ' 6 " 0 - ' 3 " 0 - ' 9 " 0 - ' 9 2R2S 1R1S " 0 - ' 9 FULL HT MIRROR SLAB STONE W/ 4" H. STONE SPLASH " 0 - ' 3 " 6 - ' 4 " 8 - ' 1 4'-0" 2" 2'-91 2" 1'-91 5'-0" 1'-0" 2" 5'-91 2" 4'-01 1'-0" 5'-2" 4" 3'-0" 2'-6" BATH 2 - WEST 01 BATH 2 - EAST 02 CLOSET 2 - EAST 03 CLOSET 2 - NORTH 04 BATH 1 - WEST 05 BATH 1 - SOUTH 06 DRAWERS WITH OPEN SHELVES ABOVE BEHIND DOORS " 6 - ' 4 9'-6" BEDROOM 1 - SOUTH 07 Z5 Z5 OPEN ADJUS SHELVING OPEN ADJUS SHELVING OPEN ADJUS SHELVING " 4 - ' 1 " 0 - ' 1 " 8 - ' 1 " 4 - ' 1 " 12 1 - ' 1 " 12 1 - ' 1 " 12 1 - ' 1 " 3 - ' 1 " 0 - ' 2 " 4 - ' 1 " 12 1 - ' 1 " 12 1 - ' 1 " 12 1 - ' 1 " 3 - ' 1 " 0 - ' 2 " 0 - ' 4 " 0 - ' 2 " 0 - ' 3 " 0 - ' 4 " 0 - ' 2 " 0 - ' 3 1'-0" 4" 6'-53 1'-0" 4" 8'-53 3'-8" 1'-0" 3'-0" 4'-0" 1'-0" 3'-0" 3'-6" BEDROOM 1 - EAST 08 BEDROOM 1 - EAST - SECTION 09 BEDROOM 1 - N/S - SECTION 10 STORAGE - EAST 11 STORAGE - NORTH 12 LAUNDRY - EAST 13 LAUNDRY - SOUTH 14 5'-0" 5'-0" 3'-6" " 0 - ' 2 " 0 - ' 7 " 0 - ' 8 I E C N E D S E R Y E L A H D A O R R O S D N W I T S A E 0 2 2 2 3 0 7 8 7 S A X E T , N I T S U A NOT PUBLISHED. ALL RIGHTS RESERVED BY MICHAEL T. LANDRUM, INC. DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF MIICHAEL T. LANDRUM, INC, ISSUED TO DESCRIBED DESIGN INTENT. THEY ARE NOT TO BE USED ON OTHER PROJECTS OR EXTENTIONS TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO TO MICHAEL T. LANDRUM, INC. CONTRACTOR, SUB-CONTRACTORS & SUPPLIERS ARE RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AND CONDITIONS AT JOB SITE, AND SHALL BE RESPONSIBLE FOR ALL LABOR & MATERIALS REQUIRED IN ACCORDANCE WITH DESIGN INTENT. MICHAEL T. LANDRUM, INC. WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE CODES AND ORDINANCES. IN CONNECTION WITH THIS PROJECT. Z2 OPEN ADJUS SHELVING OPEN ADJUS SHELVING 8'-6" 5'-8" 1R1S " 0 - ' 9 " 0 - ' 9 2R2S 2R2S " 0 - ' 9 " 0 - ' 6 " 0 - ' 3 FULL HT MIRROR SLAB STONE W/ 4" H. STONE SPLASH " 0 - ' 6 " 0 - ' 3 " 0 - ' 9 " 0 - ' 6 " 0 - ' 3 " 0 - ' 9 OPEN ADJUS SHELVING OPEN ADJUS SHELVING OPEN ADJUS SHELVING " 0 - ' 1 2'-11" 8'-0" 2'-11" 7'-6" 1'-0" 1'-0" 4'-8" 4" 2'-61 6" 5'-6" 5'-6" 6" 4" 2'-61 9'-7" BEDROOM 3 - EAST 15 CLOSET 3 - EAST 16 CLOSET 3 - SOUTH 17 BATH 3 - WEST 18 BATH 3 - EAST 19 STUDY - WEST 20 . C N I , M U R D N A L . T L E A H C I M t e e r t s s s o r l u s 2 0 5 1 6 0 0 7 7 S A X E T , N O T S U O H - 5 0 6 4 3 2 6 3 1 7 - i m o c . c n m u r d n a l t l e a h c m @ l e a h c m i i REVISIONS 10.07.26 ISSUE FOR PERMIT DATE: 10.07.26 SHEET DESCRIPTION: SHEET DESCRIPTION: ARCHITECTURAL DRAWING ARCHITECTURAL DRAWING INTERIOR ELEVATION SCALE: 1/2" = 1'-0" SHEET NUMBER: SHEET NUMBER: A 3.03 Copyright Michael T. Landrum, Inc. Copyright Michael T. Landrum, Inc. 2025 2025 STANDING SEAM PAINT GRIP METAL ROOF 30# ICE/WATER SHIELD ROOFING UNDERLAYMENT 2 X 6 RAFTERS @ 16" O.C. (VERIFY W/ STRUCTURAL) VERIFY ICE & WATER SHIELD LINER TEKTRIM PARAPET WALL CAP STAINLESS STEEL CLIP INTEGRAL GUTTER & FLASHING ICE & WATER SHIELD LINER CONDUCTOR HEAD @ SCUPPER 3 4" THICK INTEGRAL PIGMENT STEEL TROWELED STUCCO 4" DIAM. PAINT GRIP DOWN SPOUT WATER RESISTANT BARRIER ZIPSYSTEM 7 16" WALL SHEATHING HIGH DENSITY SPRAY FOAM INSULATION (2) 2 X 6 STUDS @ 16" 0.C. 3/4" T & G PLYWOOD 2 X 10 @ 16" 0.C. INSULATION 2 X 12 DOUBLE PLATE 1/2" DRYWALL 1/2" DRYWALL 11 2" FRY REGLET BASE REVEAL ENGINEER WOOD FLOORING WOOD TRUSS PER STRUCTURAL 1/2" DRYWALL 1/2" DRYWALL HIGH DENSITY SPRAY FOAM INSULATION (2) 2 X 6 STUDS @ 16" 0.C. 11 2" FRY REGLET BASE REVEAL CLAY TILE ON MUD BED PER FINISH SCHEDULE 4 " ( T Y P ) 3 4" THICK INTEGRAL PIGMENT STEEL TROWELED STUCCO 2x6 STUD (VERIFY W/ARCH.) 2 X 6 TRTD # 2 KD SYP DOUBLE PLATE 1/4" FOAM SEALER UNDERNEATH PLATE WEEP SCREED AT WALL BOTTOM " 0 - ' 9 I S E R A V ROUGH OPENING + WIDTH OF 2X4 @ PERIMETER ROUGH OPENING SIZE FOR UNIT 2 x 4 BLOCKING SQUARE SHEETROCK RETURN (TYP) AT PERIMETER NAIL FIN EXTERIOR STUCCO FACE SLOPE SILL TO DRAIN CAULK JOINT NOTE: FURR OUT AS NEEDED AT STUCCO RETURNS TO WINDOW/DOOR FRAME PLAN VIEW VARIES WRAP ICE/WATER SHIELD "PEEL & SEAL" WATERPROOFING @ PERIMETER OF WINDOW/DOOR OPENINGS; LAP EXTERIOR WALL 10" (TYP) 3/4" STUCCO ICE/WATER SHIELD (LAP 10" ONTO WALL) REVERSE SLOPE AT STUCCO RETURN TO HEADER (MIN. SLOPE TO DRAIN) VARIES CAULK JOINT CAULK JOINT STAINLESS STEEL SILL PAN OVER ICE/WATER SHIELD SLOPE STUCCO TO DRAIN @ SILL HEAD 2 X 4 SPACER RETURN SHEETROCK INTO HEADER CAULK JOINT BETWEEN SHEETROCK RETURN AND HEADER 4 5/8" WINDOW JAMB (TYP) SILL RETURN SHEETROCK INTO WINDOW JAMB ICE/WATER SHIELD (LAP 10" ONTO WALL) NOTE: SQUARE SHEETROCK CORNERS THROUGHOUT * INTERIOR DOORS TO BE MDF SMOOTH SLAB PANEL W/ INSET ROUTED 1-PANEL DETAIL AS SHOW. 4" 4" 8" x 3 3 8" ROUTER PROFILE @ BOTH FACES " 4 13 4" " 6 2 WINDOW & DOOR DETAIL (TYP.) SCALE: NTS 3 INTERIOR DOOR DETAIL SCALE: NTS 1 TYPICAL WALL SECTION SCALE: NTS MAINTAIN CONTINUOUS EDGE 4" ABOVE GRADE I E C N E D S E R Y E L A H D A O R R O S D N W I T S A E 0 2 2 2 3 0 7 8 7 S A X E T , N I T S U A NOT PUBLISHED. ALL RIGHTS RESERVED BY MICHAEL T. LANDRUM, INC. DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF MIICHAEL T. LANDRUM, INC, ISSUED TO DESCRIBED DESIGN INTENT. THEY ARE NOT TO BE USED ON OTHER PROJECTS OR EXTENTIONS TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO TO MICHAEL T. LANDRUM, INC. CONTRACTOR, SUB-CONTRACTORS & SUPPLIERS ARE RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AND CONDITIONS AT JOB SITE, AND SHALL BE RESPONSIBLE FOR ALL LABOR & MATERIALS REQUIRED IN ACCORDANCE WITH DESIGN INTENT. MICHAEL T. LANDRUM, INC. WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE CODES AND ORDINANCES. IN CONNECTION WITH THIS PROJECT. . C N I , M U R D N A L . T L E A H C I M t e e r t s s s o r l u s 2 0 5 1 6 0 0 7 7 S A X E T , N O T S U O H - 5 0 6 4 3 2 6 3 1 7 - i m o c . c n m u r d n a l t l e a h c m @ l e a h c m i i REVISIONS 10.07.26 ISSUE FOR PERMIT DATE: 10.07.26 SHEET DESCRIPTION: SHEET DESCRIPTION: ARCHITECTURAL DRAWING ARCHITECTURAL DRAWING TYPICAL WALL DETAIL SCALE: NTS SHEET NUMBER: SHEET NUMBER: A 4.01 Copyright Michael T. Landrum, Inc. Copyright Michael T. Landrum, Inc. 2025 2025 WINDOW SCHEDULE WINDOW FRAME SIZE RE: DETAILS FOR R.O. NO. TYPE SILL HT. FRAME GLAZING REMARKS DOOR NO. DOOR SIZE DOOR SCHEDULE FRAME H S E R H T S S A L G E P Y T . . E W D H O N T E S REMARKS NOTES: 1. UNLESS OTHERWISE NOTED, ALL INTERIOR DOORS TO BE 8'-0" H., 8" WIDE VERTICAL PLANK WHITE OAK DOOR (STAINED). ALL INTERIOR DOOR JAMBS TO BE KURFED TO ALLOW FOR SQUARE SHEETROCK RETURNS ON BOTH SIDES; EXTERIOR DOOR & WINDOW JAMBS TO RECEIVE SHEETROCK RETURNS @ INTERIOR WALLS,BRICK RETURNS @ EXTERIOR WALLS. 2. VERIFY SCHEDULE WITH DOOR SWINGS ON PLAN 3. UNLESS OTHERWISE NOTED, ALL EXTERIOR DOOR & WINDOW UNITS TO BE ALUMINUM,BRUSHED ANODIZED FINISH(ALTERNATE - CUSTOM COLOR POWDER COATED), INSULATED GLASS. 4. VERIFY DOOR MANUFACTURER WITH OWNER AND ARCHITECT (WESTERN SIMULATED STEEL SERIES OR EQUAL) FIXED FIXED; ROUND WINDOW TYPE INSULATED/ TEMPERED FIXED INSULATED/ TEMPERED OPERABLE; STAINED GLASS PANELS INSULATED/ TEMPERED FIXED INSULATED/ GREENHOUSE WINDOW INSULATED/ GREENHOUSE WINDOW INSULATED/ TEMPERED FIXED INSULATED/ INSULATED/ GREENHOUSE WINDOW INSULATED/ GREENHOUSE WINDOW INSULATED/ FIXED; CORNER BUTT JOINT WINDOW TEMPERED INSULATED/ FIXED; CORNER BUTT JOINT WINDOW TEMPERED INSULATED/ TEMPERED FIXED INSULATED/ FIXED TEMPERED INSULATED/ TEMPERED OPERABLE; CASEMENT WINDOW INSULATED/ TEMPERED INSULATED/ TEMPERED INSULATED/ TEMPERED FIXED INSULATED/ TEMPERED FIXED INSULATED/ TEMPERED FIXED INSULATED/ TEMPERED FIXED INSULATED/ TEMPERED FIXED INSULATED/ TEMPERED FIXED INSULATED/ TEMPERED FIXED INSULATED/ TEMPERED FIXED INSULATED/ TEMPERED FIXED INSULATED/ TEMPERED FIXED; CANTILEVERED WINDOW BAY INSULATED/ FIXED; ROUND WINDOW TEMPERED INSULATED/ TEMPERED TEMPERED INSULATED/ TEMPERED OPERABLE; CASEMENT WINDOW INSULATED/ TEMPERED INSULATED/ TEMPERED INSULATED/ TEMPERED INSULATED/ TEMPERED INSULATED/ TEMPERED INSULATED/ TEMPERED INSULATED/ TEMPERED INSULATED/ TEMPERED INSULATED/ TEMPERED INSULATED/ TEMPERED INSULATED/ TEMPERED INSULATED/ TEMPERED INSULATED/ TEMPERED INSULATED/ TEMPERED INSULATED/ TEMPERED INSULATED/ TEMPERED FIXED; ROUND WINDOW FIXED; ROUND WINDOW FIXED; ROUND WINDOW FIXED; ROUND WINDOW CASEMENT WINDOW CASEMENT WINDOW CASEMENT WINDOW CASEMENT WINDOW CASEMENT WINDOW CASEMENT WINDOW CASEMENT WINDOW CASEMENT WINDOW CASEMENT WINDOW CASEMENT WINDOW FIXED FIXED FIXED A B C D E F G H I J K L M N O P Q R S T U V W X Y Z Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8 Z9 Z10 Z11 Z12 Z13 Z14 Z15 Z16 Z17 Z18 W 10'-0" 3'-0" 4'-0" 6'-4" 2'-0" 2'-6" 2'-0" 6'-4" 8'-4" 8'-9-1/2" 6'-0" 3'-0" 8'-8" 3'-0" 2'-6" 4'-6" 4'-6" 6'-0" 14'-0" 6'-5" 6'-5" 6'-5" 6'-5" 6'-5" H 8'-0" 5'-0" 9'-0" 0'-0" 3'-0" 0'-0" 4'-2 1/4" 3'-9 3/4" 4'-2 1/4" 3'-9 3/4" 5'-0" 3'-0" 4'-2 1/4" 3'-9 3/4" 4'-2 1/4" 3'-9 3/4" 5'-0" 5'-0" 8'-0" 9'-0" 9'-0" 9'-0" 2'-0" 8'-0" 8'-0" 8'-0" 6'-4" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 3'-0" 3'-0" 0'-0" 0-0 0-0 0-0 6'-0" 0'-0" 0'-0" 0'-0" 1'-8" 0'-0" 0'-0" 0'-0" 0'-0" 0'-0" 11'-5" 8'-1 1/2" 3'-10 1/2" 2'-6" 3'-0" 8'-8" 3'-0" 2'-6" 3'-0" 3'-0" 3'-0" 2'-6" 2'-6" 2'-6" 4'-7 1/2" 3'-0" 6'-3" 6'-3" 2'-6" 6'-3" 3'-0" 3'-0" 2'-0" 9'-0" 9'-0" 9'-0" 4'-0" 5'-0" 5'-0" 5'-0" 2'-0" 2'-0" 2'-0" 5'-0" 5'-0" 3'-0" 4'-0" 2'-0" 4'-0" 4'-0" 4'-0" 6'-0" - - - 4'-0" 3'-0" 3'-0" 3'-0" 6'-0" 6'-0" 6'-0" 3'-0" 3'-0" 5'-0" 4'-0" 6'-0" 4'-0" 4'-0" 4'-0" MAT'L ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM ALUM 1 2 3 4 5 6 5 4 7 8 9 10 11 12 13 14 14 9 15 16 16 16 16 16 17 13 18 19 20 21 22 22 22 13 13 13 23 22 24 25 13 25 26 26 FINISH POWDER COATED POWDER COATED POWDER COATED POWDER COATED POWDER COATED POWDER COATED POWDER POWDER COATED POWDER COATED POWDER COATED POWDER COATED POWDER COATED POWDER COATED POWDER COATED POWDER COATED POWDER COATED POWDER COATED POWDER COATED POWDER COATED POWDER COATED POWDER COATED POWDER COATED POWDER COATED POWDER COATED POWDER COATED POWDER COATED POWDER COATED POWDER COATED COATED POWDER COATED POWDER COATED POWDER COATED POWDER COATED POWDER COATED POWDER COATED POWDER COATED POWDER COATED POWDER COATED POWDER COATED POWDER COATED POWDER COATED POWDER COATED POWDER COATED POWDER COATED POWDER COATED POWDER COATED RE: SCHED. A . D E H C S : E R THK. 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 B RE: SCHED. RE: SCHED. *GREENHOUSE WINDOW *GREENHOUSE WINDOW RE: SCHED. RE: SCHED. RE: SCHED. C . D E H C S : E R . D E H C S : E R D H . D E H C S : E R E G . D E H C S : E R . D E H C S : E R F . D E H C S : E R . D E H C S : E R . D E H C S : E R . D E H C S : E R FINISH FLOOR FINISH FLOOR Z10 Z15 O Z Z8 Z9 FINISH FLOOR TYPE 1 TYPE 2 TYPE 3 TYPE 4 TYPE 5 TYPE 6 RE: SCHED. RE: SCHED. RE: SCHED. I . D E H C S : E R . D E H C S : E R J K R . D E H C S : E R . D E H C S : E R TYPE 7 TYPE 8 TYPE 9 RE: SCHED. RE: SCHED. RE: SCHED. P Q . D E H C S : E R . D E H C S : E R S . D E H C S : E R . D E H C S : E R . D E H C S : E R 3'-0" L . D E H C S : E R 2'-4" TYPE 10 RE: SCHED. . D E H C S : E R . D E H C S : E R T U V W X RE: SCHED. 4'-0" M 3'-0" N " 0 - ' 5 . D E H C S : E R . D E H C S : E R 8'-8" TYPE 11 RE: SCHED. 2'-4" TYPE 12 Y . D E H C S : E R . D E H C S : E R TYPE 13 TYPE 14 TYPE 15 TYPE 16 TYPE 17 W H THK. TYPE MAT'L FINISH MAT'L FINISH 101 102 103 104 105 106 107 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 3'-0" 2'-8" 2'-8" 2'-8" 3'-0" 3'-0" 3'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 11'-1 1/2" 11'-0" 6'-0" 11'-5" 11'-0" 12'-0" 2'-8" 3'-0" 6'-0" 5'-0" 3'-0" 3'-0" 6'-0" 2'-6" 3'-0" 6'-0" 2'-8" 2'-8" 3'-0" 3'-0" 3'-0" 6'-0" 9'-0" 9'-0" 2'-6" 2'-8" 2'-8" 3'-0" 2'-0" 2'-8" 2'-8" 2'-8" 2'-8" 2'-8" 2'-8" 2'-8" 2'-8" 11'-0" 7'-0" 2'-8" 2'-8" 2'-8" 2'-8" 2'-8" 2'-8" 2'-10" 2'-10" 2'-8" 2'-8" 11'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 2 2 2 1 3/4" 2 2 1 3/4" 1 3/4" 1 3/4" 2 1 3/4" 1 3/4" 2 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 2 2 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 2 2 1 3/4" 1 3/4" 1 3/4" 1 3/4" 2 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 2 A A A A A A A B C D A E F G H H I H A F H H H A A J K K A A A A A A A A H H A A A L M A A A H E A H H H H L WHITE OAK WHITE OAK WHITE OAK WHITE OAK WHITE OAK WHITE OAK WHITE OAK ALUM ALUM ALUM WHITE OAK ALUM ALUM WHITE OAK WHITE OAK WHITE OAK ALUM WHITE OAK WHITE OAK ALUM WHITE OAK WHITE OAK WHITE OAK WHITE OAK WHITE OAK WHITE OAK ALUM ALUM WHITE OAK WHITE OAK WHITE OAK WHITE OAK WHITE OAK WHITE OAK WHITE OAK WHITE OAK WHITE OAK WHITE OAK WHITE OAK WHITE OAK WHITE OAK ALUM ALUM WHITE OAK WHITE OAK WHITE OAK WHITE OAK ALUM WHITE OAK WHITE OAK WHITE OAK WHITE OAK WHITE OAK ALUM STAINED STAINED STAINED STAINED STAINED STAINED STAINED POWDER COATED POWDER COATED POWDER COATED STAINED POWDER COATED POWDER COATED STAINED STAINED STAINED POWDER COATED STAINED STAINED POWDER COATED STAINED STAINED STAINED STAINED STAINED STAINED PAINTED PAINTED STAINED STAINED STAINED STAINED STAINED STAINED STAINED STAINED STAINED STAINED STAINED STAINED STAINED POWDER COATED POWDER COATED STAINED STAINED STAINED STAINED POWDER COATED STAINED STAINED STAINED STAINED STAINED POWDER COATED WHITE OAK WHITE OAK WHITE OAK WHITE OAK WHITE OAK WHITE OAK WHITE OAK ALUM ALUM ALUM WHITE OAK ALUM ALUM WHITE OAK WHITE OAK WHITE OAK ALUM WHITE OAK WHITE OAK ALUM WHITE OAK WHITE OAK WHITE OAK WHITE OAK WHITE OAK WHITE OAK ALUM ALUM WHITE OAK WHITE OAK WHITE OAK WHITE OAK WHITE OAK WHITE OAK WHITE OAK WHITE OAK WHITE OAK WHITE OAK WHITE OAK WHITE OAK WHITE OAK ALUM ALUM WHITE OAK WHITE OAK WHITE OAK WHITE OAK ALUM WHITE OAK WHITE OAK WHITE OAK WHITE OAK WHITE OAK ALUM STAINED STAINED STAINED STAINED STAINED STAINED STAINED POWDER COATED POWDER COATED POWDER COATED STAINED POWDER COATED POWDER COATED STAINED STAINED STAINED POWDER COATED STAINED STAINED POWDER COATED STAINED STAINED STAINED STAINED STAINED STAINED PAINTED PAINTED STAINED STAINED STAINED STAINED STAINED STAINED STAINED STAINED STAINED STAINED STAINED STAINED STAINED POWDER COATED POWDER COATED STAINED STAINED STAINED STAINED POWDER COATED STAINED STAINED STAINED STAINED STAINED POWDER COATED INSULATED/ TEMPERED INSULATED/ TEMPERED INSULATED/ TEMPERED INSULATED/ TEMPERED INSULATED/ TEMPERED EXTERIOR DOOR EXTERIOR DOOR 8'-0" H. EXTERIOR DOUBLE DOOR W/ TRANS0M & SIDELIGHTS 8'-0" H. EXTERIOR DOUBLE DOOR W/ TRANS0M 8'-0" H. EXTERIOR SIDING DOOR W/ TRANSOM; (4) E.Q. PANELS EXTERIOR DOOR EXTERIOR DOUBLE DOOR POCKET DOOR POCKET DOOR POCKET DOOR INSULATED/ TEMPERED EXTERIOR DOOR WITH SIDELIGHTS POCKET DOOR INSULATED/ TEMPERED EXTERIOR DOUBLE DOOR POCKET DOOR POCKET DOOR POCKET DOOR EXTERIOR DOOR EXTERIOR DOOR DOUBLE DOOR GARAGE DOOR; CLAD WITH WOOD GARAGE DOOR; CLAD WITH WOOD POCKET DOOR POCKET DOOR INSULATED/ TEMPERED INSULATED/ TEMPERED EXTERIOR DOUBLE SIDING WITH SIDELIGHTS EXTERIOR DOOR W/ SIDE LIGHT INSULATED/ TEMPERED POCKET DOOR EXTERIOR DOOR POCKET DOOR POCKET DOOR POCKET DOOR POCKET DOOR INSULATED/ TEMPERED EXTERIOR DOUBLE SIDING WITH SIDELIGHTS RE: SCHED. RE: SCHED. RE: SCHED. RE: SCHED. 101 106 217 301 306 315 201 102 107 218 302 309 316 103 104 105 204 222 303 310 319 212 223 304 311 305 314 FINISH FLOOR . D E H C S : E R " 0 - ' 8 A RE: SCHED. RE: SCHED. 6'-0" B RE: SCHED. 205 318 313 . D E H C S : E R 206 213 E RE: SCHED. F 220 221 . D E H C S : E R FINISH FLOOR FINISH FLOOR 207 . D E H C S : E R . D E H C S : E R G H RE: SCHED. RE: SCHED. . D E H C S : E R 312 324 202 . D E H C S : E R 208 214 320 209 215 321 211 216 322 307 308 323 317 228 " 0 - ' 1 " 0 - ' 8 . D E H C S : E R " 0 - ' 8 C D RE: SCHED. RE: SCHED. RE: SCHED. 219 . D E H C S : E R 210 2'-9" I J . D E H C S : E R . D E H C S : E R I E C N E D S E R Y E L A H D A O R R O S D N W I T S A E 0 2 2 2 3 0 7 8 7 S A X E T , N I T S U A NOT PUBLISHED. ALL RIGHTS RESERVED BY MICHAEL T. LANDRUM, INC. DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF MIICHAEL T. LANDRUM, INC, ISSUED TO DESCRIBED DESIGN INTENT. THEY ARE NOT TO BE USED ON OTHER PROJECTS OR EXTENTIONS TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO TO MICHAEL T. LANDRUM, INC. CONTRACTOR, SUB-CONTRACTORS & SUPPLIERS ARE RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AND CONDITIONS AT JOB SITE, AND SHALL BE RESPONSIBLE FOR ALL LABOR & MATERIALS REQUIRED IN ACCORDANCE WITH DESIGN INTENT. MICHAEL T. LANDRUM, INC. WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE CODES AND ORDINANCES. IN CONNECTION WITH THIS PROJECT. . C N I , M U R D N A L . T L E A H C I M . D E H C S : E R . D E H C S : E R t e e r t s s s o r l u s 2 0 5 1 6 0 0 7 7 S A X E T , N O T S U O H - 5 0 6 4 3 2 6 3 1 7 - i m o c . c n m u r d n a l t l e a h c m @ l e a h c m i i 3'-0" Z1 FINISH FLOOR " 0 - ' 1 1'-4" TYPE 18 . D E H C S : E R " 0 - ' 5 " 0 - ' 4 " 0 - ' 5 " 0 - ' 3 " 0 - ' 1 8'-8" 4'-0" Z2 TYPE 19 . D E H C S : E R . D E H C S : E R " 0 - ' 5 " 0 - ' 4 3'-0" Z3 Z4 " 0 - ' 1 1'-4" TYPE 20 RE: SCHED. RE: SCHED. RE: SCHED. RE: SCHED. RE: SCHED. RE: SCHED. Z5 Z6 Z7 Z12 . D E H C S : E R . D E H C S : E R Z11 3'-0" . D E H C S : E R . D E H C S : E R . D E H C S : E R . D E H C S : E R 3'-0" Z13 . D E H C S : E R . D E H C S : E R 3'-0" Z14 Z16 . D E H C S : E R . D E H C S : E R . D E H C S : E R . D E H C S : E R Z17 Z18 TYPE 21 TYPE 22 TYPE 23 TYPE 24 TYPE 25 TYPE 26 3'-0" M K L REVISIONS 10.07.26 ISSUE FOR PERMIT DATE: DATE: 10.07.26 SHEET DESCRIPTION: SHEET DESCRIPTION: ARCHITECTURAL DRAWING ARCHITECTURAL DRAWING WINDOW AND DOOR SCHEDULE SCALE: NTS SHEET NUMBER: SHEET NUMBER: A 5.01 Copyright Michael T. Landrum, Inc. Copyright Michael T. Landrum, Inc. 2025 2025 CRAWL SPACE ACCESS A3 ELEVATOR HIDDEN STORAGE FUTURE BATH A3 HALL 1 GFI WP A3 WP A3 WP WP GFI WP GFI A3 A3 WP GFI WP GFI CABANA A3 A3 REFRIG ICE GFI GFI MECH/STORAGE 1 STAIR 1 UP POOL GRILL 1 GFI GFI SYMBOL DESCRIPTION WATT/VOLT/LAMP LOCATION REMARKS 3" LOW VOLTAGE RECESSED 50W/12V/MR16 FL/ THRU-OUT REMARKS A3 DOWNLIGHT/ BAFFLE TRIM/ INTEGRAL TRANSFORMER/ WALL WASH RECESSED STEP LIGHTS NOT APPLICABLE THRU-OUT REMARKS NUTONE BATH EXHAUST FAN VENT, HEAT, LIGHT AND NIGHT LIGHT 250W/ NO LAMP THRU-OUT REMARKS LOW VOLTAGE CYLINDER TRACK 50W/12V/MR16 NSP THRU-OUT REMARKS HEAD/ INTEGRAL TRANSFORMER/ SINGLE CIRCUIT TRACK/ TYPICAL FOR ALL LENGTHS NOT APPLICABLE THRU-OUT REMARKS 1' X 4' FLUORESCENT THRU-OUT REMARKS UC 2 UC3 XENON/ UNDER CABINET 20W/12V/2XG4 BI-PIN THRU-OUT REMARKS LIGHT/ TWO LAMP XENON/ UNDER CABINET 20W/12V/G4 BI-PIN THRU-OUT REMARKS LIGHT/ THREE LAMP FLOOD LIGHTS NOT APPLICABLE THRU-OUT REMARKS MP MP NOT APPLICABLE THRU-OUT REMARKS LIGHT SWITCH NOT APPLICABLE THRU-OUT REMARKS 3-WAY LIGHT SWITCH NOT APPLICABLE THRU-OUT REMARKS RHEOSTAT NOT APPLICABLE THRU-OUT REMARKS GFI USB GROUND FAULT INTERRUPTERS NOT APPLICABLE THRU-OUT REMARKS DUPLEX OUTLET WITH USB PORTS NOT APPLICABLE THRU-OUT REMARKS DUPLEX OUTLET NOT APPLICABLE THRU-OUT REMARKS QUAD QUADPLEX OUTLET NOT APPLICABLE THRU-OUT REMARKS QUAD QUADPLEX OUTLET NOT APPLICABLE THRU-OUT REMARKS TV SD CO S RECESSED IN FLOOR W/ ANODIZED ALUM. COVER CABLE TELEVISION NOT APPLICABLE THRU-OUT REMARKS TELEPHONE JACK NOT APPLICABLE THRU-OUT REMARKS SMOKE DETECTOR NOT APPLICABLE THRU-OUT REMARKS CARBON MONOXIDE DETECTOR NOT APPLICABLE THRU-OUT REMARKS CEILING MOUNT SPEAKER NOT APPLICABLE THRU-OUT REMARKS VOLUME CONTROL NOT APPLICABLE THRU-OUT REMARKS I E C N E D S E R Y E L A H D A O R R O S D N W I T S A E 0 2 2 2 3 0 7 8 7 S A X E T , N I T S U A NOT PUBLISHED. ALL RIGHTS RESERVED BY MICHAEL T. LANDRUM, INC. DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF MIICHAEL T. LANDRUM, INC, ISSUED TO DESCRIBED DESIGN INTENT. THEY ARE NOT TO BE USED ON OTHER PROJECTS OR EXTENTIONS TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO TO MICHAEL T. LANDRUM, INC. CONTRACTOR, SUB-CONTRACTORS & SUPPLIERS ARE RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AND CONDITIONS AT JOB SITE, AND SHALL BE RESPONSIBLE FOR ALL LABOR & MATERIALS REQUIRED IN ACCORDANCE WITH DESIGN INTENT. MICHAEL T. LANDRUM, INC. WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE CODES AND ORDINANCES. IN CONNECTION WITH THIS PROJECT. . C N I , M U R D N A L . T L E A H C I M t e e r t s s s o r l u s 2 0 5 1 6 0 0 7 7 S A X E T , N O T S U O H - 5 0 6 4 3 2 6 3 1 7 - i m o c . c n m u r d n a l t l e a h c m @ l e a h c m i i REVISIONS 10.07.26 ISSUE FOR PERMIT DATE: DATE: 10.07.26 SHEET DESCRIPTION: SHEET DESCRIPTION: ARCHITECTURAL DRAWING ARCHITECTURAL DRAWING LOWER LEVEL ELECTRICAL PLAN SCALE: 3/16" = 1'-0" SHEET NUMBER: SHEET NUMBER: E 1.01 Copyright Michael T. Landrum, Inc. Copyright Michael T. Landrum, Inc. 2025 2025 COURTYARD PERGOLA NORTH COURTYARD WP GFI WP GFI WP GFI WP GFI GRILL 2 GFI READING NOOK WP GFI WP GFI MUD/OFFICE WP GFI WP GFI WP GFI GFI GFI PORTE COCHERE PROVIDE POWER FOR GARAGE OPENER GARAGE PROVIDE POWER FOR GARAGE OPENER WP GFI GFI GFI GFI GFI GFI GARAGE STORAGE WP GFI WP GFI POTTING SHED/ DOG WASH A3 STAIR OPEN TO ABOVE TO LTS ABOVE PRIMARY CLOSET DOG DOOR WP GFI MUD BATH GFI LAUNDRY PASS-THRU ARCH CLOSET CLOSET LAUNDRY GFI PRIMARY GALLERY UCL GFI GFI SD CO ARCH W/D GFI W/D GFI UCL COFFEE BAR UCL A3 A3 CO SD PRIMARY BEDROOM VAULTED CEILING FIREPLACE A3 A3 A3 GFI KNEE A3 SPACE @ VANITY GFI PRIMARY BATH GFI A3 A3 WP WP A3 WP LINEN A3 A3 WP GFI PRIMARY TERRACE DN GFI UCL GFI GFI GFI UCL GFI PROVIDE POWER FOR RANGE AND VENTHOOD GFI GFI REFRIGERATOR FLOWER ARRANGING GFI FREEZER GFI 48" RANGE W/ 48" VENT HOOD KITCHEN GFI DW DW PROVIDE POWER FOR DISPOSAL GFI STORAGE BREAKFAST GFI POWDER ROOM A3 PANTRY STORAGE SITTING SITTING SCREEN/ DIVIDER A3 A3 GALLERY TO SWITCH ABOVE A3 STAIR A3 A3 A3 HALL 2 BARREL VAULT @ HALL PROVIDE POWER FOR FUTURE ELEVATOR UCL GFI FUTURE ELEVATOR BUTLER'S PANTRY GFI UCL DW GFI DINING CLOSET POOL WATER FEATURE WP GFI WP GFI ENTRY TERRACE DN GFI WP ENTRY ENTRY PORCH UCL BAR GFI LIVING TERRACE ENTRY STAIR PATH TO GARDEN GFI WP LIVING 28 X 21 A3 FIRE PLACE PLANTER SYMBOL DESCRIPTION WATT/VOLT/LAMP LOCATION REMARKS 3" LOW VOLTAGE RECESSED 50W/12V/MR16 FL/ THRU-OUT REMARKS A3 DOWNLIGHT/ BAFFLE TRIM/ INTEGRAL TRANSFORMER/ WALL WASH RECESSED STEP LIGHTS NOT APPLICABLE THRU-OUT REMARKS NUTONE BATH EXHAUST FAN VENT, HEAT, LIGHT AND NIGHT LIGHT 250W/ NO LAMP THRU-OUT REMARKS LOW VOLTAGE CYLINDER TRACK 50W/12V/MR16 NSP THRU-OUT REMARKS HEAD/ INTEGRAL TRANSFORMER/ SINGLE CIRCUIT TRACK/ TYPICAL FOR ALL LENGTHS NOT APPLICABLE THRU-OUT REMARKS 1' X 4' FLUORESCENT THRU-OUT REMARKS UC 2 UC3 XENON/ UNDER CABINET 20W/12V/2XG4 BI-PIN THRU-OUT REMARKS LIGHT/ TWO LAMP XENON/ UNDER CABINET 20W/12V/G4 BI-PIN THRU-OUT REMARKS LIGHT/ THREE LAMP FLOOD LIGHTS NOT APPLICABLE THRU-OUT REMARKS MP MP NOT APPLICABLE THRU-OUT REMARKS LIGHT SWITCH NOT APPLICABLE THRU-OUT REMARKS 3-WAY LIGHT SWITCH NOT APPLICABLE THRU-OUT REMARKS RHEOSTAT NOT APPLICABLE THRU-OUT REMARKS GFI USB GROUND FAULT INTERRUPTERS NOT APPLICABLE THRU-OUT REMARKS DUPLEX OUTLET WITH USB PORTS NOT APPLICABLE THRU-OUT REMARKS DUPLEX OUTLET NOT APPLICABLE THRU-OUT REMARKS QUAD QUADPLEX OUTLET NOT APPLICABLE THRU-OUT REMARKS QUAD QUADPLEX OUTLET NOT APPLICABLE THRU-OUT REMARKS TV SD CO S RECESSED IN FLOOR W/ ANODIZED ALUM. COVER CABLE TELEVISION NOT APPLICABLE THRU-OUT REMARKS TELEPHONE JACK NOT APPLICABLE THRU-OUT REMARKS SMOKE DETECTOR NOT APPLICABLE THRU-OUT REMARKS CARBON MONOXIDE DETECTOR NOT APPLICABLE THRU-OUT REMARKS CEILING MOUNT SPEAKER NOT APPLICABLE THRU-OUT REMARKS VOLUME CONTROL NOT APPLICABLE THRU-OUT REMARKS I E C N E D S E R Y E L A H D A O R R O S D N W I T S A E 0 2 2 2 3 0 7 8 7 S A X E T , N I T S U A NOT PUBLISHED. ALL RIGHTS RESERVED BY MICHAEL T. LANDRUM, INC. DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF MIICHAEL T. LANDRUM, INC, ISSUED TO DESCRIBED DESIGN INTENT. THEY ARE NOT TO BE USED ON OTHER PROJECTS OR EXTENTIONS TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO TO MICHAEL T. LANDRUM, INC. CONTRACTOR, SUB-CONTRACTORS & SUPPLIERS ARE RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AND CONDITIONS AT JOB SITE, AND SHALL BE RESPONSIBLE FOR ALL LABOR & MATERIALS REQUIRED IN ACCORDANCE WITH DESIGN INTENT. MICHAEL T. LANDRUM, INC. WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE CODES AND ORDINANCES. IN CONNECTION WITH THIS PROJECT. . C N I , M U R D N A L . T L E A H C I M t e e r t s s s o r l u s 2 0 5 1 6 0 0 7 7 S A X E T , N O T S U O H - 5 0 6 4 3 2 6 3 1 7 - i m o c . c n m u r d n a l t l e a h c m @ l e a h c m i i REVISIONS 10.07.26 ISSUE FOR PERMIT DATE: DATE: 10.07.26 SHEET DESCRIPTION: SHEET DESCRIPTION: ARCHITECTURAL DRAWING ARCHITECTURAL DRAWING FIRST FLOOR ELECTRICAL PLAN SCALE: 3/16" = 1'-0" SHEET NUMBER: SHEET NUMBER: E 1.02 Copyright Michael T. Landrum, Inc. Copyright Michael T. Landrum, Inc. 2025 2025 WP BATH 1 GFI BATH 2 CLOSET 2 WP GFI LINEN CO SD CO SD A3 A3 BEDROOM 2 A3 A3 A3 A3 WINDOW SEAT CO SD A3 CO SD STOR. BEDROOM 1 15 X 14'-6" A3 CLOSET 1 HALL PROVIDE POWER FOR FUTURE ELEVATOR LANDING ELEVATOR STORAGE A3 A3 A3 A3 CO SD CO SD A3 LAUNDRY BROOM GFI GFI W/D GFI UCL GFI A3 A3 PP A3 BALCONY TERRACE TO LTS BELOW BEDROOM 3 GFI WP GFI WP GFI WP A3 A3 MECH/ STORAGE 2 CLOSET 3 GFI BATH 3 WP A3 A3 A3 A3 GUEST BEDROOM GFI GFI GUEST BATH WP WP STUDY A3 A3 CO SD CO SD GUEST CLOSET A3 A3 GUEST TERRACE A3 GUEST ENTRY REFRIG DRWR GFI MECH/ STORAGE 3 STAIR OPEN TO BELOW TO LTS BELOW SYMBOL DESCRIPTION WATT/VOLT/LAMP LOCATION REMARKS 3" LOW VOLTAGE RECESSED 50W/12V/MR16 FL/ THRU-OUT REMARKS A3 DOWNLIGHT/ BAFFLE TRIM/ INTEGRAL TRANSFORMER/ WALL WASH RECESSED STEP LIGHTS NOT APPLICABLE THRU-OUT REMARKS NUTONE BATH EXHAUST FAN VENT, HEAT, LIGHT AND NIGHT LIGHT 250W/ NO LAMP THRU-OUT REMARKS LOW VOLTAGE CYLINDER TRACK 50W/12V/MR16 NSP THRU-OUT REMARKS HEAD/ INTEGRAL TRANSFORMER/ SINGLE CIRCUIT TRACK/ TYPICAL FOR ALL LENGTHS NOT APPLICABLE THRU-OUT REMARKS 1' X 4' FLUORESCENT THRU-OUT REMARKS UC 2 UC3 XENON/ UNDER CABINET 20W/12V/2XG4 BI-PIN THRU-OUT REMARKS LIGHT/ TWO LAMP XENON/ UNDER CABINET 20W/12V/G4 BI-PIN THRU-OUT REMARKS LIGHT/ THREE LAMP FLOOD LIGHTS NOT APPLICABLE THRU-OUT REMARKS MP MP NOT APPLICABLE THRU-OUT REMARKS LIGHT SWITCH NOT APPLICABLE THRU-OUT REMARKS 3-WAY LIGHT SWITCH NOT APPLICABLE THRU-OUT REMARKS RHEOSTAT NOT APPLICABLE THRU-OUT REMARKS GFI USB GROUND FAULT INTERRUPTERS NOT APPLICABLE THRU-OUT REMARKS DUPLEX OUTLET WITH USB PORTS NOT APPLICABLE THRU-OUT REMARKS DUPLEX OUTLET NOT APPLICABLE THRU-OUT REMARKS QUAD QUADPLEX OUTLET NOT APPLICABLE THRU-OUT REMARKS QUAD QUADPLEX OUTLET NOT APPLICABLE THRU-OUT REMARKS TV SD CO S RECESSED IN FLOOR W/ ANODIZED ALUM. COVER CABLE TELEVISION NOT APPLICABLE THRU-OUT REMARKS TELEPHONE JACK NOT APPLICABLE THRU-OUT REMARKS SMOKE DETECTOR NOT APPLICABLE THRU-OUT REMARKS CARBON MONOXIDE DETECTOR NOT APPLICABLE THRU-OUT REMARKS CEILING MOUNT SPEAKER NOT APPLICABLE THRU-OUT REMARKS VOLUME CONTROL NOT APPLICABLE THRU-OUT REMARKS I E C N E D S E R Y E L A H D A O R R O S D N W I T S A E 0 2 2 2 3 0 7 8 7 S A X E T , N I T S U A NOT PUBLISHED. ALL RIGHTS RESERVED BY MICHAEL T. LANDRUM, INC. DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF MIICHAEL T. LANDRUM, INC, ISSUED TO DESCRIBED DESIGN INTENT. THEY ARE NOT TO BE USED ON OTHER PROJECTS OR EXTENTIONS TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO TO MICHAEL T. LANDRUM, INC. CONTRACTOR, SUB-CONTRACTORS & SUPPLIERS ARE RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AND CONDITIONS AT JOB SITE, AND SHALL BE RESPONSIBLE FOR ALL LABOR & MATERIALS REQUIRED IN ACCORDANCE WITH DESIGN INTENT. MICHAEL T. LANDRUM, INC. WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE CODES AND ORDINANCES. IN CONNECTION WITH THIS PROJECT. . C N I , M U R D N A L . T L E A H C I M t e e r t s s s o r l u s 2 0 5 1 6 0 0 7 7 S A X E T , N O T S U O H - 5 0 6 4 3 2 6 3 1 7 - i m o c . c n m u r d n a l t l e a h c m @ l e a h c m i i REVISIONS 10.07.26 ISSUE FOR PERMIT DATE: DATE: 10.07.26 SHEET DESCRIPTION: SHEET DESCRIPTION: ARCHITECTURAL DRAWING ARCHITECTURAL DRAWING SECOND FLOOR ELECTRICAL PLAN SCALE: 3/16" = 1'-0" SHEET NUMBER: SHEET NUMBER: E 1.03 Copyright Michael T. Landrum, Inc. Copyright Michael T. Landrum, Inc. 2025 2025 WOOD FRAMING: (continued) FLOOR TRUSSES: DRAINAGE, WATERPROOFING AND VENTILATION: REINFORCED CONCRETE: DESIGN DATA Trusses to be designed by truss engineer employed by truss 1. manufacturer and in accordance with - National Design Specification for Wood Construction, AF&PA, National Design Standard for Metal Plate Connected Wood - Truss Construction, ANSI/TPI 1-1995 - Local code jurisdictions Design trusses for the minimum line and point loads shown on 2. plan (line loads from upper walls are minimum 100 lb/ft u.n.o.) and, unless noted otherwise on the plan, the following minimum area loads: The following items are beyond the scope of the structural engineer and are therefore the responsibility of others. The client is responsible for arranging for the design of these systems. Any mention of these items on these drawings is for information purposes only and does not relieve the client of these responsibilities. STANDARD SPECIFICATIONS AND CODES: Structural Concrete Building Code Requirements for Reinforced Concrete, ACI 318-02. Drainage systems including surface drainage, any area inlets, grate drains, french drains and subgrade drain pipes. 1. Waterproofing systems including vapor barriers, roofing, flashing, waterproofing and drip edges. Concrete shall meet the following requirements: 3000 psi C33 1 1/2" 28 day strength: aggregate type: max. aggregate size: MATERIALS: Ventilation systems including crawlspace and attic. 2. Reinforcing steel shall meet the following requirements: - - - - - Restrain strongback at each end. Locate strongback as close to bottom chord as possible. Compaction shall be to 95 percent of maximum laboratory 3. density determined in accordance with ASTM D 698. Material shall be within three percent of optimum moisture at time of compaction. CONCRETE CRACK CONTROL: NAILING SCHEDULE: joist to sill or girder, toe nail 1"x6" subfloor or less to each joist, face nail 2" subfloor to joist or girder, blind and face nail sole plate to joist or blocking, face nail top or sole plate to stud, end nail stud to sole plate, toe nail 3-8d 2-8d 2-16d 16d @16"o.c. 2-16d 3-8d or 2-16d double studs, face nail 10d @24"o.c. double top plates, face nail sole plate to joist or blocking at braced wall panels double top plates, minimum 48" offset of end joints, face nail in lapped area blocking between joists or rafters to top plate, toe nail rim joist to top plate, toe nail top plates, laps at corners and intersections, face nail built-up header, two pieces with 1/2" spacer continued header, two pieces ceiling joists to plate, toe nail continuous header to stud, toe nail ceiling joist, laps over partitions, face nail ceiling joist to parallel rafters, face nail rafter to plate, toe nail 1" brace to each stud and plate, face nail 1"x6" sheathing to each bearing, face nail 1"x8" sheathing to each bearing, face nail wider than 1"x8" sheathing to each bearing, face nail 10d @24"o.c.. 3-16d @16" o.c. 8-16d 3-8d 8d @ 6"o.c. 2-10d 16d @ 16"o.c. each edge 16d @ 16"o.c. each edge 3-8d 4-8d 3-10d 3-10d 2-16d 2-8d or 2 stpls 1 3/4 2-8d or 2 stpls 1 3/4 3-8d or 3 stpls 1 3/4 3-8d or 4 stpls 1 3/4 built-up corner studs 10d @ 24"o.c. built-up girders and beams, 2" lumber layers, at top and bottom and staggered. Two nails at ends and at each splice. 10d @ 32"o.c. 2" planks roof rafters to ridge, valley or hip rafters: toe nail face nail collar ties to rafters, face nail 2-16d @ ea. bearing 4-16d 3-16d 3-8d 5/16" to 1/2" wood structural panel 6d (wall) 8d (roof) 6" edge 12" field 19/32" to 1" wood structural panel 8d 6" edge 12" field 1-1/8" to 1-1/4" wood structural panel 10d 6" edge 12" field 1/2" gypsum sheathing 4" edge8" field 1-1/2" galv. roofing nail or 1-1/2" screw, type w or s 5/8" gypsum sheathing 4" edge8" field 1-3/4" galv. roofing nail or 1-5/8" screw, type w or s GENERAL: 1. Dimensions refer to rough surfaces. The contractor must verify all dimensions prior to start of construction the engineer shall be notified of any discrepancies or inconsistencies. 2. All drawings are considered part of the contract documents. The contractor shall be responsible for review and coordination of all drawings and specifications prior to the start of construction. Any discrepancies that occur shall be brought to the attention of the engineer prior to the start of construction so that clarification can be issued. Any work in conflict with the contract documents or any code requirements shall be corrected by the contractor at his own expense and at no expense to the owner or structural engineer. 3. These drawings are based on architectural drawings by: Michael Landrum received July 29, 2026 All work shall conform to the minimum standards of the building 4. code as well as any other regulating authority over any portion of the work including those additional codes and standards listed in the structural notes and specifications. 5. The engineer shall not control and shall not be responsible for construction means, methods, techniques, sequences or procedures; for safety precautions and programs in connection with the work; for acts or omissions of the contractor, subcontractor or for any persons performing the work; or for the failure of any of them to carry out the work in accordance with the contract documents. Site observations by field representatives of the engineer are 6. solely for the purpose of determining if the work of the contractor is proceeding in accordance with the structural contract drawings. This limited site observation should not be construed as exhaustive or continuous to check the quality or quantity of the work, but rather an effort to guard the owner against defects or deficiencies in the work of the contractor. 7. All structures require periodic maintenance to extend life span and to insure structural integrity from exposure to the environment. A planned program of maintenance shall be established by the building owner. This program shall include items such as painting of structural steel, protective coating for concrete, sealants, caulked joints, expansion joints, control joints, spalls and cracks in concrete. - STRUCTURAL FASTENERS: NAILS: All nails sinker nails per ASTM F1667-95, steel wire, t-head diamond point, round smooth shank, bright. FINISHES: Where a preservative other than borate is used and connectors and fasteners (including nails and bolts) contact treated lumber, use stainless steel connectors and fasteners, unless builder and supplier can demonstrate that pressure treatment is not corrosive to galvanized metal. GLUE: Glue shall meet the requirements of the American Plywood Association adhesive specification AFG-01 and shall be applied as directed by the glue manufacturer. Glue may be applied manually or with pneumatic or electric equipment. EXPANSION ANCHORS: Simpson Strong-Bolt, 1/2" dia., installed as directed by manufacturer. 6. a. WOOD SCREWS, LAG SCREWS AND BOLTS: Wood screws shall comply with ASME B18.6.1. Unless noted otherwise, screws are #8. Lag screws shall comply with ASME B18.2.1. Unless noted otherwise, lag screws are 1/2" dia. by length as required to penetrate secondary member entirely minus 1/2". Applicable ASTM specifications for bolts: For common bolts: For nuts: For washers: For threaded rod: ASTM A307, Gr.A (Fu= 60 ksi) ASTM A563 ASTM F436 ASTM A36 (Fy=36 ksi, Fu = 58-80 ksi) WOOD FRAMING: GENERAL: ROOF AND CEILING STRUCTURE NOTES: Lumber: All materials and workmanship shall conform with the 1. requirements of the latest "National Design Specifications for Stress-Grade Lumber and its Fastenings" by National Forest Products Association. Unless noted otherwise, all lumber shall be Southern Pine 2. (S4S) conforming to the standard grading and dressing rules of the Southern Pine Inspection Bureau. Wall studs shall be S-P-F lumber. Unless indicated otherwise, the minimum grade of structural 3. members shall be as follows: studs : other lumber : no. 2 no. 2 Microlam (LVL) laminated veneer lumber: LVL shall be 4. manufactured by Trus Joist, and design shall be in accordance with ICBO ES ER-4979. Where shown on plan, provide purlin same size as rafters and 1. braced with (2)2x4 braces at 48" o.c.. Slope braces between 45 degrees and vertical and lap onto rafters and nail Ridge board braced as shown on plan with (2) 2x4 braces 2. sloped between 60 degrees and vertical. Brace roof only as shown on plan. Contractor must compare 3. resulting rafter spans to allowable span chart and contact engineer for approval of any necessary additional braces. Unless noted otherwise, for ridges, hips and valleys, use one 4. mill size larger than the common rafters it supports. Center any splices on an approved brace point. At point-of-support for braces, adequately block walls and 5. beams to prevent rotation and horizontal movement. Maximum Ceiling Joist Span Tables: Compare with ceiling joist sizes shown on plan and contact engineer if discrepancies are found. #2 Southern Pine Ceiling Joists: spacing: : 2x6 : 2x8 : 2x10 : 2x12 24" o.c.16" o.c. 12" o.c. 9'-10" 12'-0" 13'-11" 12'-6" 15'-3" 17'-7" 14'-9" 18'-1" 20'-11" 17'-5" 21'-8" 24'-0" #2 Douglas Fir-South Ceiling Joists: spacing: : 2x6 : 2x8 : 2x10 : 2x12 24" o.c.16" o.c. 12" o.c. 10'-4" 12'-8" 14'-1" 13'-1" 16'-0" 18'-6" 16'-0" 19'-7" 22'-7" 18'-6" 22'-8" 24'-0" from International Residential Code Table R802.4(2) with 20 psf live load, 10 psf dead load, L/240 allowable deflection Maximum Rafter Span Tables for rafters with Light Roof Covering and Not Supporting Ceiling: Compare with rafter sizes shown on plan and contact engineer if discrepancies are found. #2 Southern Pine Rafters: spacing: : 2x6 : 2x8 : 2x10 : 2x12 24" o.c.16" o.c. 12" o.c. 11'-0" 13'-6" 15'-7" 13'-11" 17'-1" 19'-8" 16'-6" 20'-3" 23'-5" 19'-6" 23'-10" 24'-0" #2 Douglas Fir-South Rafters: spacing: : 2x6 : 2x8 : 2x10 : 2x12 24" o.c.16" o.c. 12" o.c. 11'-7" 14'-1" 15'-6" 14'-8" 17'-11" 20'-5" 17'-10" 21'-11" 24'-0" 20'-9" 24'-0" 24'-0" from International Residential Code Table R802.5.1(1) with 20 psf live load, 10 psf dead load, L/180 allowable Unless noted otherwise, install Simpson H2.5 hurricane ties at Block beams, joists, rafters and trusses at bearing as required 8. every rafter. 9. to prevent rotation. Plywood or OSB: Sheathing/single floor shall be exterior grade 5. bear the following APA span rating: 6. 15/32" roof sheathing : 1 1/8" single floor t&g : 15/32" wall sheathing : 32/16 48 oc 32/16 All floor sheathing shall be glued to the joists. The field-glued 6. system shall comply with the recommendations of the American Plywood Association. At roofs, unsupported plywood panel end and side edges shall 7. be backed with 2x4 flat blocking or Simpson panel sheathing clips. 8. All framing connectors shall be Simpson Strong-Tie. Where connectors and fasteners contact treated lumber, use stainless steel connectors and fasteners, unless builder and supplier can demonstrate that pressure treatment is not corrosive to galvanized metal. STUD WALL NOTES: 1. See architectural drawings for exact plate height. Compare architect's plate heights and wall sizes to the table 2. below for acceptable maximum. Contact engineer if discrepancies are found. 7. supporting roof only 2x4 @ 24" o.c. 2x4 @ 16" o.c. 2x6 @ 24" o.c. 2x6 @ 16" o.c. 10'-0" 12'-0" 16'-0" 18'-0" supporting one floor and a roof 2x4 @ 24" o.c. not permitted 10'-0" 2x4 @ 16" o.c. 14'-0" 2x6 @ 24" o.c. 18'-0" 2x6 @ 16" o.c. 3. Bottom plate: Treated 2x same width as wall studs. Anchor with 1/2" dia. anchor bolt embedded 7" and spaced maximum 6'-0" o.c.. Locate anchors within 12" of each end of each plate section. Attach interior walls to slab with pafs spaced at 12" o.c. with 4. two pins 6" and 10" from each end of each plate. 5. Where joists, trusses or rafters are spaced more than 16" o.c. and bearing studs below are spaced at 24" members must bear within 5" of studs beneath. Drilling and notching - Studs: In exterior walls or bearing partitions, notch a maximum of 25%. In nonbearing partitions, notch a maximum of 40%. b. c. Any stud, bore/drill no closer than 5/8" to edge of stud and not in the same section as a cut or notch and a maximum diameter of 40%. d. Studs may be bored to 60% of stud width provided the stud is doubled and no more than two successive studs are bored. With engineer's prior approval simpson HSS/SS stud shoes may be used in specific cases of notches or bores exceeding these maximums. 7. Drilling and notching - Top plate: When piping in a wall necessitates the cutting of a top plate by more than 50% its width, use a Simpson RPS strap tie at each plate with six 16d nails each side of notch. POWDER-ACTUATED FASTENERS (PAFS): WALL BRACING NOTES: PAFs shall comply with CABO NER-272. where permitted by details, wood sill plates may be fastened to the concrete slab using powder driven pins following manufacturer's recommendations. The fastening system shall have ICBO approval. Pins shall have a minimum shank diameter of 0.177", a minimum length of 3 1/4", and be spaced per the details. FINISHING MATERIALS: 1. Masonry Veneer: Maximum wall height: Install over a backing of wood wall and a. limited in height to a maximum of 30 feet above the foundation (38 feet permitted at the top of gable ends). b. Masonry on wood: Where indicated on plans, masonry weighing less than 40 psf may be supported on wood framing (deflection limited to L/600). Install a movement joint between the veneer supported by wood and the veneer supported by foundation. Anchorage: Anchor to wood wall framing with c. corrosion-resistant 22 gage x 7/8" corrugated sheet metal ties spaced a maximum of 24" horizontally and 19.5" vertically. Lintels over openings: Support masonry on loose lintels per d. code supported on masonry to foundation at each end. Isolation joints: Install vertical isolation/expansion joints at e. approximately 25 feet on center. 1. Braced wall lines: Using braced wall panel construction in accordance with the prescriptive methods of IRC, brace walls as follows: b. a. Exterior walls: Continuous structural panel sheathing (thickness as noted above), including above and below openings, shall be used on the outside face of all exterior walls (blocking of edges not required), and any braced wall lines that include an exterior wall are considered adequately braced. Interior walls: 1x4 let-in braces sloped between 45 and 60 degrees from horizontal and notched into top and bottom plates and intervening studs and attached with two 8d nails at each plate/stud or simpson WB wall bracing installed in accordance with manuf. specs. or 1/2" thickness gypsum board minimum 48" wide attached to studs w/ 6d nails @ 7" o.c.. Bracing locations: As described below. where 2. architectural layout will not permit the application of these presciptive methods, use engineered shear walls as indicated and detailed on these drawings. Contractor must review drawings prior to construction and contact engineer if discrepancies are found. a. For one story or top story of two or three: Locate at each end and at least every 25 feet on center but not less than 16% of braced wall line. b. First story of two story second story of three story: Locate at each end and at least every 25 feet on center but not less than 25% of braced wall line. HANGER SCHEDULE Member Size Simpson Designation Floor Load Roof Load 2x4 2x6 2x8 2x10 2x12 (2)2x4 (2)2x6 (2)2x8 (2)2x10 (2)2x12 (3)2x6 (3)2x8 (3)2x10 (3)2x12 LU24 LU26 LU28 LU28 LU210 LUS24-2 LUS26-2 LUS28-2 LUS210-2 LUS210-2 LUS26-3 LUS28-3 LUS210-3 LUS210-3 445 665 890 890 555 830 1,110 1,110 1,110 1,390 765 960 1,000 1,250 1,265 1,765 1,585 2,210 1,765 2,210 1,000 1,250 1,265 1,585 1,765 2,210 1,765 2,210 Locate braced wall panels within 12'-6" of the end of each 3. braced wall line. (2)1.75x11.875 HGUS48 6,805 7,925 (2)1.75x14 HGUS410 8,780 8,940 Gypsum: Comply with GA-216-2000 "Application and Finishing 2. of Gypsum Board." Flexibility details in GA-216-2000 such as control joints and corner details shall be used. 4. lines. Out-of-plane offsets up to 4'-0" are permitted in braced wall (2)1.75x16 HGUS410 8,780 8,940 Tile: Comply with American National Standard Specifications 3. for the Installation of Ceramic Tile. Flexibility details in specification such as control and expansion joints shall be used. Alternate braced wall panel: In one and two story houses, a 5. panel constructed in accordance with IRC R602.10.6 can be considered a braced panel. (2)1.75x18 HGUS414 10,015 10,015 (3)1.75x11.875 HGUS5.50/12 9,155 9,155 (3)1.75x14 HGUS5.50/14 10,015 10,015 (3)1.75x16 HGUS5.50/14 10,015 10,015 (3)1.75x18 HGUS5.50/14 10,015 10,015 Top chord live load: Top chord dead load: Bottom chord dead load: Maximum deflections: under live load only: under live + dead load: 40 psf 10 psf 5 psf L/360 L/240 3. Prior to fabrication, truss design drawings bearing the seal and registration number of Texas registered engineer shall be submitted to: Builder/Architect for approval of all truss dimensions, pitches - and elevations; - Engineer for appoval of truss layout and design inputs. 4. Strongbacks: Install continuous 2x6 (min.) strongbacks through floor trusses at mid-span and spaced a maximum of 10'-0" o.c. - Fasten with three 16d nails at each vertical. SELECT FILL : Scarify and re-compact all areas to receive fill. Surfaces 1. steeper than 1 vertical to 4 horizontal which are to receive fill must be benched. 2. Select underslab fill material shall be composed of hard durable particles of gravel or crushed stone and shall meet the following criteria: Gradation: sieve size 1-3/4" 1-1/2" 3/4" No. 4 No. 40 % finer by weight 100 85 - 100 45 - 75 25 - 70 10 - 40 Material passing the no. 40 sieve: % minus no. 40 25-40 10-25 max. PI 15 20 min. PI 3 4 Where vertical web members are not suitably located for - strongback attachment, install vertical 2x4 block fastened with two 16d nails at top and bottom chords. Maximum liquid limit of the minus no. 40 material shall be 45. No organic matter is permitted. 5. Alterations to trusses: Cutting and altering trusses is not permitted. 6. Bracing: Restrain top chord with floor sheathing and bottom chord with ceiling gypsum. Restrain trusses at points of bearing to prevent toppling. 7. Load transfer through inter-floor space: Use same-size blocking to transfer load from upper walls/columns to lower supporting walls/columns/beams. do not place point loads on unsupported floor sheathing. 8. Transitory floor vibration and sound transmission: The floor system includes no measures to specifically control floor vibration or sound transmission. Expect similar performance to similar systems in similar projects. Contact engineer prior to construction if specific performance criteria are desired. ROOF TRUSSES: Trusses to be designed by truss engineer employed by truss 1. manufacturer and in accordance with National Design Specification for Wood Construction, AF&PA, Placements should be in lifts not exceeding six inches after 4. compaction. 5. Backslopes: Select fill shall extend a minimum of three feet horizontally beyond slab edges before sloping downward at 1V:2H backslope to natural soil. Backslope fill shall be well compacted. If perimeter grade beams are carried into natural soil, backslope fill is not required. REQUIRED TESTING AND APPROVALS · Fill material composition, placement and compaction shall be tested and approved by the Geotechnical Engineer. A 100 pound sample of proposed fill material shall be submitted to the Geotechnical Engineer a minimum 7 days in advance of filling and compaction operations to determine Moisture-Density Relationship. Testing Frequency:Not less than one field density test per 2,000 square feet and minimum 3 tests per lift. · · If foundation bearing elements (including exterior grade beams and interior piers or hard points) penetrate fill, THE ABOVE TESTING AND APPROVALS ARE NOT REQUIRED, and the underslab fill will be considered forming fill. National Design Standard for Metal Plate Connected Wood Truss Construction, ANSI/TPI 1-1995 FILL PLACEMENT: Local code jurisdictions Design roof trusses for the minimum line and point loads 2. shown on plan and, the following minimum area loads, unless noted otherwise on the plan, : Top chord live load: Top chord dead load: Bot. chord live load: Bot. chord dead load: Maximum deflections: under live load only: under live+dead load: 20 psf 10 psf Light roof 20 psf Heavy roof 10 psf 5 psf L/360 L/240 1. Use select fill as specified below (not on site fill) in areas under building footprints. All compaction to minimum of 95% of the maximum dry density obtained from standard proctor (ASTM D 698). No remove and replace required beyond organics and top soil. Scarify and re-compact all areas to receive fill. surfaces 2. steeper than IV:4H which are to receive fill must be benched. 3. Select underslab fill material shall be composed of hard durable particles of gravel or crushed stone and shall meet the following criteria: A. Gradation 3. Prior to fabrication, truss design drawings bearing the seal and registration number of Texas registered engineer shall be submitted to: - - Builder/architect for approval of all truss dimensions, pitches and elevations; B. Engineer for approval of truss layout and design inputs. 4. Strongbacks: install continuous 2x6 (min.) strongbacks through trusses at mid-span and spaced a maximum of 10'-0" o.c. Fasten with three 16d nails at each vertical. sieve size 1-3/4" 1-1/2" 3/4" NO. 4 NO. 40 % finer by wt. 100 85-100 45-75 25-70 10-40 Material passing the no. 40 sieve shall meet the following: % passing no. 40 25-40 10-25 Maximum liquid limit of the -no. 40 material shall be 45. No organic matter is permitted. max. PI 15 20 Where vertical web members are not suitably located for strongback attachment, install vertical 2x4 block fastened with two 16d nails at bottom chords. Placements should be in lifts not exceeding six inches after 4. compaction. A one inch sand level-up course may be placed immediately below concrete slab and waterproof membrane. - - - - - - - Proposed fill material should be submitted to testing agency for 5. approval, in advance of placement. Backslopes: Select fill shall extend a minimum of three feet 6. horizontally before sloping downward at 1V:2H backslope to natural soil. Backslope fill shall be well compacted. If perimeter grade beams are carried into natural soil, backslope fill is not required. Restrain strongback at each end. Locate strongback as close to bottom chord as possible. 5. Alterations to trusses: cutting and altering trusses is not permitted. 6. Truss bracing: - - - - - Restrain top chord with roof sheathing. Brace bottom chord with 1x4 spaced per truss designers requirements (8'-0" maximum). Restrain trusses at points of bearing with blocking and hurricane ties per details. Brace web compression members with continuous 2x4 per truss designers requirements. Install 2x4 X-braces at third points of common truss span. Extend X-braces from girder truss to girder truss. min. PI 3 4 Welding shall conform to the American Welding Society 1. Standard D1.1. Unless noted otherwise, electrodes for welding shall conform 2. to E70XX (SMAW) ANCHOR RODS 1. Anchor rods: ASTM F1554 grade 36 2. Adhesive anchors shall have been tested and qualified for use in accordance with ICC-ES AC308 for cracked and uncracked concrete recognition. Pre-approved adhesive anchors include: - Hilti HIT-HY 200 A/R V3 (ICC-ES ESR-4868) GROUT Grout: non-metallic, non-shrink grout with a minimum strength 1. of 6000 psi. HEADED CONCRETE ANCHORS: Headed concrete anchors shall be nelson headed concrete 1. anchors (or approved equal), and shall conform to ASTM A108, grades C-1010 through C-1020. Anchors shall be automatically end welded with suitable stud 2. welding equipment in the shop or in the field. welding shall be in accordance with the recommendations of the nelson stud welding company. GENERAL BUILDING CODE: The contract documents are based on the requirements of THE 2024 INTERNATIONAL RESIDENTIAL CODE. Ground snow load: Wind speed (3 second gust): Exposure category: Seismic design category: Live Loads: exterior balconies : deck : fire escapes : passenger vehicle garages : attics without storage : attics with storage : rooms other : sleeping rooms : stairs : guardrails and handrails : 5 psf 115 mph C A 60 psf 40 40 50 10 20 40 30 40 200 lbs #3 to #18: ASTM A615 grade 60 REINFORCING STEEL COVERAGE: For layer nearest surface unless specified otherwise on drawings: Concrete surfaces cast against and permanently in contact 1. with earth: #3 to #18 bars: 3" Roof Live Load: 2. Concrete surfaces exposed to earth or weather: #3 to #5 bars: #6 to #18 bars: 1.5" 2" roof slope 4:12 4:12 to <12:12 12:12 and up tributary area 201- 600 16 14 12 0- 200 20 psf 16 12 601- up 12 12 12 Concrete surfaces not exposed to weather or in contact with 3. earth: Dead Loads: #3 to #11 bars in slabs & walls: #3 to #18 bars in beams & columns: 1" 1.5" DETAILS: roofing: asphalt shingle (2 psf) Contractor shall submit proposed locations for construction 1. joints not shown on drawings for review by the Architect and Structural Engineer. flooring: ceramic tile 3/4" thick (10 psf) hardwood 7/8" thick (4 psf) carpet and pad (2 psf) . g n i r e e n g n E y f f i u D f o i n o s s m r e p i n e t t i r w s s e r p x e e h t Embedded conduits, pipes, and sleeves shall meet the 2. requirements of ACI 318-02, Section 6.3. 1. Install crack control joints @ 15'-0" o.c.e.w. If crack control is not a consideration as determined by both the builder and the owner, then the joints may be eliminated. Create crack control joints by tooling or sawcutting to a depth 2. of one third the slab thickness. Tool the base of all drops-in-slab to function as control joints. STRUCTURAL STEEL STANDARD SPECIFICATIONS AND CODES: Structural steel design, fabrication and construction governed by ASD Specification for Structural Steel Buildings; Specification for Structural Joints using ASTM A325 or A490 bolts; and Code of Standard Practice for Steel Buildings and Bridges. MATERIAL: Note: Materials indicated above were assumed in design. Prior to construction, builder must compare to actual materials and weights and contact engineer if differences are found. Actual dead loads must not exceed the loads indicated. Austin, Texas (512) 402-0074 Firm Registration No. F-8637 Deflections: The building movement specified below is anticipated and should be considered by the contractor in the performance of the work. rafters : floors/ceilings : others : L/180 L/360 L/240 STRUCTURAL OBSERVATION: 1. The structural engineer of record, or his designate, shall provide structural observation of the structural system for general conformance to the approved plans and specifications at significant construction stages and at completion of the structural system as noted elsewhere in the contract documents. The contractor shall notify the engineer a minimum of 72 hours 2. prior to the date the observation is required. 07 oct 2026 PROJECT NUMBER: 26014 CLIENT: Brian and Caroline Haley i i g n n a b o t t s r i f t u o h t i w , y t r a p d r i h t a o t d e n g s s a i r o , r e n n a m y n a n i i d e p o c r o d e g n a h c , d e c u d o r p e r e b t o n y a m d n a i g n i r e e n g n E y f f u D f o y t r e p o r p i e r a s g n w a r d e s e h T All hot rolled structural steel plates, shapes and bars shall be 1. new steel conforming to ASTM A6-98A. 3. The following items require structural observation: - - Foundation reinforcing and pre-pour setup Framing prior to insulation FOUNDATION: The foundation design is based on the geotechnical 1. investigation performed by HOLT ENGINEERING dated April 15, 2026 (file no. 11-35024). All pier shafts must be inspected and approved by geotechnical engineer prior to concrete. Unless noted otherwise on these drawings, structural steel 2. shall be as follows: W-shapes: C-shapes: L-shapes: HSS-shapes: ASTM A992 ASTM A36 ASTM A36 ASTM A500, Fy = 46 KSI All connection material including bearing plates, gusset plates, 3. stiffener plates, angles, etc.: ASTM A36 (unless higher grade is required by strength) CONNECTIONS: 1. See typical details on drawings. STRUCTURAL BOLTS AND THREADED FASTENERS: Unless noted otherwise, all bolts in structural connections shall 1. conform to ASTM A325 type 1. 2. 3. Threaded rod: F 1554 grade 36 Pins: ASTM A36 WELDING i e c n e d s e R y e a H l d a o R r o s d n W i t s a E 0 2 2 2 s a x e T , n i t s u A ISSUE: package 0 - for permit 1 - for permit date 14 aug 2026 07 oct 2026 SHEET TITLE: Notes SHEET NUMBER: S1.0 52'-5" 3'-3" 21'-4 3/4" 8'-10" 2'-0" 27'-8" 2'-0" 20'-0" 32'-6" 170'-0 3/4" 0 . 3 S a 1 2a S3.0 2a S3.0 " 8 - ' 2 " 4 - ' 6 " 2 / 1 3 - ' 9 " 2 / 1 2 - ' 8 " 0 - ' 0 1 " 2 / 1 3 - ' 9 9 " 1 1 - ' 9 2 " 2 / 1 8 - ' 8 1 " 6 - ' 7 " 8 - ' 6 1c S3.0 1a S3.0 1a S3.0 0 . 3 S a 1 2a S3.0 0 . 3 S a 2 0 . 3 S a 2 " 2 1 0 . 3 S a 1 1a S3.0 " 2 / 1 1 - ' 3 1 1a S3.0 0 . 3 S a 1 0 . 3 S p 1 2a S3.0 e p o s l 12" 2e S3.0 " 6 " 6 0 . 3 S e 2 0 . 3 S e 2 " 6 " 6 24'-11 1/2" 1p S3.0 2a S3.0 0 . 3 S c 1 1c S3.0 0 . 3 S a 2 0 . 3 S a 2 0 . 3 S d 2 0 . 3 S a 1 0 . 3 S c 1 0 . 3 S g 1 0 . 3 S g 1 0 . 3 S p 1 0 . 3 S a 1 2a S3.0 2c S3.0 2d S3.0 x . 3 S a 2 e p o s l e p o s l 0 . 3 S d 2 0 . 3 S a 2 1a S3.0 0 . 3 S a 1 22'-2" 1h S3.0 2'-4" 1a S3.0 . 0 3 S a 2 0 . 3 S a 2 0 . 3 S a 2 0 . 3 S a 1 1a S3.0 1'-8" 2t S3.0 1a S3.0 1a S3.0 4s S3.0 0 . 3 S p 1 0 . 3 S a 4 " 5 - ' 5 2 " 0 - ' 9 5 " 1 1 - ' 4 " 2 / 1 6 - ' 9 " 0 - ' 6 Concrete Pier per 1a S3.0 (typical) " 4 / 1 1 1 - ' 3 4 " 2 / 1 1 - ' 5 " 0 - ' 7 1 " 1 1 - ' 3 " 9 - ' 2 1 " 4 / 3 1 - ' 5 1h S3.0 0 . 3 S a 1 2a S3.0 0 . 3 S a 2 0 . 3 S a 2 3a S3.0 1a S3.0 0 . 3 S a 3 " 6 " 6 5" thick concrete slab-on-ground reinforced w/ #4 @ 16" o.c.e.w. 2a S3.0 0 . 3 S e 2 0 . 3 S a 2 " 6 " 6 4a S3.0 6'-8 3/4" 2a S3.x 2a S3.x 0 . 3 S s 4 2'-2" 1h S3.0 2d S3.0 1p S3.0 4a S3.0 0 . 3 S t 2 1a S3.0 . 0 3 S a 1 . 0 3 S a 1 . 0 3 S p 1 0 . 3 S s 4 Foundation Plan 3/16" = 1'-0" plan north PLAN NOTES: 1. See S1.0 for notes. 0 . 3 S a 3 2a S3.0 . m s i 0 . 3 S p 1 " 6 " 6 . m s i 0 . 3 S p 1 1a S3.0 " 2 / 1 1 - ' 3 1 " 2 / 1 3 - ' 9 9 19'-10" 20'-8" 15'-9 1/2" 1'-8" 23'-3 1/2" 26'-7" 4'-6 3/4" 2'-2" 11'-1" 12'-5" 24'-0" 6'-0" 2'-0" 170'-0 3/4" " 8 - ' 2 " 4 - ' 6 " 2 / 1 3 - ' 1 3 . g n i r e e n g n E y f f i u D f o i n o s s m r e p i n e t t i r w s s e r p x e e h t i i g n n a b o t t s r i f t u o h t i w , y t r a p d r i h t a o t d e n g s s a i r o , r e n n a m y n a n i i d e p o c r o d e g n a h c , d e c u d o r p e r e b t o n y a m d n a i g n i r e e n g n E y f f u D f o y t r e p o r p i e r a s g n w a r d e s e h T Austin, Texas (512) 402-0074 Firm Registration No. F-8637 07 oct 2026 PROJECT NUMBER: 26014 CLIENT: Brian and Caroline Haley i e c n e d s e R y e a H l d a o R r o s d n W i t s a E 0 2 2 2 s a x e T , n i t s u A " 0 1 - ' 7 2 " 0 - ' 3 " 2 1 / 0 - ' 5 1 ISSUE: package 0 - for permit 1 - for permit date 14 aug 2026 07 oct 2026 SHEET TITLE: Foundation Plan SHEET NUMBER: S2.0 . g n i r e e n g n E y f f i u D f o i n o s s m r e p i n e t t i r w s s e r p x e e h t i i g n n a b o t t s r i f t u o h t i w , y t r a p d r i h t a o t d e n g s s a i r o , r e n n a m y n a n i i d e p o c r o d e g n a h c , d e c u d o r p e r e b t o n y a m d n a i g n i r e e n g n E y f f u D f o y t r e p o r p i e r a s g n w a r d e s e h T 0 1 x 2 ) 3 ( r d h 0 1 x 2 ) 3 ( r d h (2) 2x12 flush open for stair (2) 2x12 flush n o i g n h t a e h s r o o l f . c . o " 4 2 . x a m @ s e s s u r t r o o l f " 0 2 0 1 x 2 ) 3 ( r d h L V L 6 1 x 5 7 . 1 ) 3 ( r d h Lower Ceiling Framing Plan plan north 3/16" = 1'-0" PLAN NOTES: 1. See S1.0 for notes. 12" dia. concrete column 12" dia. concrete column 12" dia. concrete column 12" dia. concrete column Austin, Texas (512) 402-0074 Firm Registration No. F-8637 07 oct 2026 PROJECT NUMBER: 26014 CLIENT: Brian and Caroline Haley i e c n e d s e R y e a H l d a o R r o s d n W i t s a E 0 2 2 2 s a x e T , n i t s u A ISSUE: package 0 - for permit 1 - for permit date 14 aug 2026 07 oct 2026 SHEET TITLE: Lower Level Ceiling Framing Plan SHEET NUMBER: S2.1 (2) 2x6 hdr 2 1 x 2 ) 3 ( r d h 2 1 x 2 ) 3 ( r d h 8 x 2 ) 3 ( r d h (3) 2x10 hdr (3) 2x10 hdr 2 1 x 2 ) 3 ( r d h 2 1 x 2 ) 3 ( r d h 2 1 x 2 ) 3 ( r d h 2 1 x 2 ) 3 ( r d h (2) 2x12 flush open for stair (2) 2x12 flush n o i g n h t a e h s r o o l f . c . o " 4 2 . x a m @ s e s s u r t r o o l f " 0 3 L V L 5 7 8 . 1 1 x 5 7 . 1 ) 3 ( r d h 0 1 x 2 ) 3 ( r d h 0 1 x 2 ) 3 ( r d h L V L 8 1 x 5 7 . 1 ) 2 ( h s u l f (3) 1.75x18 LVL flush roof trusses form ceiling 2 1 x 2 ) 3 ( r d h 2 1 x 2 ) 3 ( r d h 2 1 x 2 ) 3 ( r d h L V L 6 1 x 5 7 . 1 ) 3 ( r d h n o i g n h t a e h s r o o l f . c . o " 4 2 . x a m @ s e s s u r t r o o l f " 0 3 12" dia. concrete column (2) 1.75x11.875 LVL flush 12" dia. concrete column 12" dia. concrete column 12" dia. concrete column L V L 6 1 x 5 7 . 1 ) 3 ( r d h s t s o i j 2 1 x 2 . c . o " 4 2 . x a m @ L V L 5 7 8 . 1 1 x 5 7 . 1 ) 3 ( r d h L V L 5 7 8 . 1 1 x 5 7 . 1 ) 2 ( h s u l f s t s o i j 2 1 x 2 . c . o " 4 2 . x a m @ L V L 5 7 8 . 1 1 x 5 7 . 1 ) 2 ( h s u l f s t s o i j 2 1 x 2 . c . o " 4 2 . x a m @ L V L 5 7 8 . 1 1 x 5 7 . 1 ) 2 ( h s u l f s t s o i j 2 1 x 2 . c . o " 4 2 . x a m @ L V L 5 7 8 . 1 1 x 5 7 . 1 ) 2 ( h s u l f L V L 5 7 8 . 1 1 x 5 7 . 1 ) 2 ( h s u l f 12" dia. concrete column 12" dia. concrete column 12" dia. concrete column 12" dia. concrete column (2) 1.75x11.875 LVL flush 2 1 x 2 ) 3 ( r d h 2 1 x 2 ) 3 ( r d h 2 1 x 2 ) 3 ( r d h 2 1 x 2 ) 3 ( r d h L V L 5 7 8 . 1 1 x 5 7 . 1 ) 3 ( r d h First Floor Ceiling Framing Plan plan north 3/16" = 1'-0" PLAN NOTES: 1. See S1.0 for notes. (3) 2x10 hdr 12" dia. concrete column 12" dia. concrete column 12" dia. concrete column 12" dia. concrete column 12" dia. concrete column (3) 1.75x14 LVL hdr (3) 2x12 hdr (3) 1.75x14 LVL hdr (3) 2x12 hdr (3) 2x12 hdr (3) 2x12 hdr (3) 2x8 hdr (3) 2x8 hdr 2x6 ceiling joists @ max. 24" o.c. (3) 2x10 hdr (3) 2x10 hdr (3) 2x10 hdr (3) 2x10 hdr (2) 2x6 hdr 8 x 2 ) 2 ( r d h 2 1 x 2 ) 3 ( r d h 2 1 x 2 ) 3 ( r d h floor sheathing on 20" floor trusses @ max. 24" o.c. (3) 2x10 hdr (3) 1.75x18 LVL flush floor sheathing on Top chord sloping floor trusses @ max. 24" o.c. waterproofing, flashing, slope and drip edge designed by other (3) 1.75x14 LVL hdr (3) 1.75x14 LVL hdr 8 x 2 ) 3 ( r d h 8 x 2 ) 3 ( r d h s t s o i j g n i l i e c 6 x 2 . c . o " 4 2 . x a m @ L V L 6 1 x 5 7 . 1 ) 2 ( h s u l f (2) 1.75x16 LVL flush L V L 6 1 x 5 7 . 1 ) 2 ( h s u l f floor sheathing on 20" floor trusses @ max. 24" o.c. floor sheathing on Top chord sloping floor trusses @ max. 24" o.c. waterproofing, flashing, slope and drip edge designed by other (2) 1.75x16 LVL flush (3) 1.75x11.875 LVL hdr (3) 1.75x11.875 LVL hdr (3) 1.75x11.875 LVL hdr (3) 1.75x11.875 LVL hdr (3) 1.75x11.875 LVL hdr HSS 4x4x3/16 steel column per 1a S3.1 floor sheathing on 20" floor trusses @ max. 24" o.c. W18x40 steel beam floor sheathing on Top chord sloping floor trusses @ max. 24" o.c. waterproofing, flashing, slope and drip edge designed by other n o i g n h t a e h s r o o l f . c . o " 4 2 . x a m @ s e s s u r t r o o l f " 0 2 HSS 4x4x3/16 steel column per 1a S3.1 HSS 4x4x3/16 steel column per 1a S3.1 (2) 1.75x16 LVL flush (2) 2x12 flush open for stair L V L 6 1 x 5 7 . 1 ) 2 ( h s u l f (3) 2x12 hdr (3) 2x12 hdr s t s o i j g n i l i e c 0 1 x 2 . c . o " 4 2 . x a m @ (2) 2x6 hdr L V L 5 7 8 . 1 1 x 5 7 . 1 ) 3 ( r d h 2 1 x 2 ) 3 ( r d h (3) 2x8 hdr (3) 2x8 hdr 2x6 ceiling joists @ max. 24" o.c. 2x10 ceiling joists @ max. 24" o.c. (3) 2x10 hdr (3) 1.75x11.875 LVL hdr L V L 5 7 8 . 1 1 x 5 7 . 1 ) 2 ( h s u l f s t s o i j g n i l i e c 8 x 2 . c . o " 4 2 . x a m @ s t s o i j g n i l i e c 6 x 2 . c . o " 4 2 . x a m @ 8 x 2 ) 3 ( r d h 8 x 2 ) 3 ( r d h (2) 1.75x14 LVL flush 0 1 x 2 ) 3 ( r d h 0 1 x 2 ) 3 ( r d h s t s o i j g n i l i e c 2 1 x 2 . c . o " 6 1 . x a m @ (2) 1.75x14 LVL flush 8 x 2 ) 3 ( r d h 8 x 2 ) 3 ( r d h 8 x 2 ) 2 ( r d h (2) 1.75x11.875 LVL flush 0 1 x 2 ) 3 ( r d h 0 1 x 2 ) 3 ( r d h (2) 2x6 hdr 8 x 2 ) 3 ( r d h 6 x 2 ) 3 ( r d h (3) 2x8 hdr (3) 2x8 hdr . c . o " 4 2 . x a m @ s t s o i j g n i l i e c 6 x 2 (3) 2x8 hdr (3) 2x8 hdr S2.2 . g n i r e e n g n E y f f i u D f o i n o s s m r e p i n e t t i r w s s e r p x e e h t i i g n n a b o t t s r i f t u o h t i w , y t r a p d r i h t a o t d e n g s s a i r o , r e n n a m y n a n i i d e p o c r o d e g n a h c , d e c u d o r p e r e b t o n y a m d n a i g n i r e e n g n E y f f u D f o y t r e p o r p i e r a s g n w a r d e s e h T Austin, Texas (512) 402-0074 Firm Registration No. F-8637 07 oct 2026 PROJECT NUMBER: 26014 CLIENT: Brian and Caroline Haley i e c n e d s e R y e a H l d a o R r o s d n W i t s a E 0 2 2 2 s a x e T , n i t s u A ISSUE: package 0 - for permit 1 - for permit date 14 aug 2026 07 oct 2026 SHEET TITLE: First Floor Ceiling Framing Plan SHEET NUMBER: S2.2 (3) 2x6 hdr (3) 2x6 hdr (3) 2x6 hdr (3) 2x6 hdr (3) 2x6 hdr (3) 2x6 hdr 2x6 ceiling joists @ max. 24" o.c. 2x12 ceiling joists @ max. 24" o.c. L V L 5 7 8 . 1 1 x 5 7 . 1 ) 2 ( h s u l f L V L 5 7 8 . 1 1 x 5 7 . 1 ) 2 ( h s u l f L V L 5 7 8 . 1 1 x 5 7 . 1 ) 2 ( h s u l f (3) 2x10 hdr 2x6 ceiling joists @ max. 24" o.c. (3) 2x10 hdr (3) 1.75x11.875 LVL hdr (3) 2x6 hdr (3) 2x6 hdr (3) 2x6 hdr (3) 2x6 hdr s t s o i j g n i l i e c 0 1 x 2 . c . o " 4 2 . x a m @ (3) 2x10 hdr 6 x 2 ) 3 ( r d h 0 1 x 2 ) 3 ( r d h (3) 2x6 hdr 6 x 2 ) 3 ( r d h 6 x 2 ) 3 ( r d h (3) 2x6 hdr (3) 2x6 hdr 8 x 2 ) 3 ( r d h 8 x 2 ) 3 ( r d h 0 1 x 2 ) 2 ( h s u l f (2) 2x10 flush s t s o i j g n i l i e c 6 x 2 . c . o " 4 2 . x a m @ 6 x 2 ) 3 ( r d h 6 x 2 ) 3 ( r d h 6 x 2 ) 3 ( r d h (2) 1.75x11.875 LVL flush s t s o i j g n i l i e c 0 1 x 2 . c . o " 4 2 . x a m @ (2) 2x6 hdr 0 1 x 2 ) 3 ( r d h 0 1 x 2 ) 3 ( r d h 8 x 2 ) 2 ( r d h (2) 2x6 hdr 6 x 2 ) 3 ( r d h 6 x 2 ) 3 ( r d h Second Floor Ceiling Framing Plan 3/16" = 1'-0" plan north PLAN NOTES: 1. See S1.0 for notes. 6 x 2 ) 3 ( r d h 6 x 2 ) 3 ( r d h 6 x 2 ) 3 ( r d h 6 x 2 ) 3 ( r d h (3) 2x8 hdr (3) 2x8 hdr L V L 5 7 8 . 1 1 x 5 7 . 1 ) 2 ( h s u l f (3) 2x8 hdr (3) 1.75x18 LVL hdr 2x10 ceiling joists @ max. 24" o.c. L V L 5 7 8 . 1 1 x 5 7 . 1 ) 2 ( h s u l f (3) 2x6 hdr (3) 2x6 hdr (3) 2x8 hdr (3) 2x8 hdr s t s o i j g n i l i e c 0 1 x 2 . c . o " 4 2 . x a m @ (2) 1.75x11.875 LVL flush 2 1 x 2 ) 3 ( r d h 6 x 2 ) 3 ( r d h (2) 1.75x11.875 LVL flush 6 x 2 ) 3 ( r d h 6 x 2 ) 3 ( r d h Austin, Texas (512) 402-0074 Firm Registration No. F-8637 07 oct 2026 PROJECT NUMBER: 26014 CLIENT: Brian and Caroline Haley i e c n e d s e R y e a H l d a o R r o s d n W i t s a E 0 2 2 2 s a x e T , n i t s u A ISSUE: package 0 - for permit 1 - for permit date 14 aug 2026 07 oct 2026 SHEET TITLE: Second Floor Ceiling Framing Plan SHEET NUMBER: S2.3 S2.3 . g n i r e e n g n E y f f i u D f o i n o s s m r e p i n e t t i r w s s e r p x e e h t i i g n n a b o t t s r i f t u o h t i w , y t r a p d r i h t a o t d e n g s s a i r o , r e n n a m y n a n i i d e p o c r o d e g n a h c , d e c u d o r p e r e b t o n y a m d n a i g n i r e e n g n E y f f u D f o y t r e p o r p i e r a s g n w a r d e s e h T roof sheathing on 2x8 rafters @ max. 24" o.c. 1.75x9.25 LVL hip 1.75x9.25 LVL hip 1.75x9.25 LVL valley roof sheathing on 2x8 rafters @ max. 24" o.c. 1.75x9.25 LVL hip 1.75x9.25 LVL valley e g d i r L V L 5 2 . 9 x 5 7 . 1 hip hip n o i g n h t a e h s f o o r . c . o " 4 2 . x a m @ s r e t f a r 8 x 2 1.75x9.25 LVL hip 1.75x9.25 LVL ridge 1.75x9.25 LVL ridge roof sheathing on 2x8 rafters @ max. 24" o.c. roof sheathing on 2x8 rafters @ max. 24" o.c. 1.75x9.25 LVL hip 1.75x9.25 LVL valley e g d i r L V L 5 2 . 9 x 5 7 . 1 n o i g n h t a e h s f o o r . c . o " 4 2 . x a m @ s r e t f a r 8 x 2 n o i g n h t a e h s f o o r . c . o " 4 2 . x a m @ s r e t f a r 8 x 2 1.75x9.25 LVL hip 1.75x9.25 LVL hip roof sheathing on 2x8 rafters @ max. 24" o.c. Roof Framing Plan plan north 1/4" = 1'-0" PLAN NOTES: 1. 2. See S1.0 for notes. Unless noted otherwise, rafters are 2x8 @ 24" o.c. n o i g n h t a e h s f o o r . c . o " 4 2 . x a m @ s e s s u r t f o o r 1.75x9.25 LVL valley 1.75x9.25 LVL valley 1.75x9.25 LVL hip 1.75x9.25 LVL ridge 1.75x9.25 LVL hip 1.75x9.25 LVL hip n o i g n h t a e h s f o o r . c . o " 4 2 . x a m @ s r e t f a r 8 x 2 1.75x9.25 LVL hip 1.75x9.25 LVL hip roof sheathing on 2x8 rafters @ max. 24" o.c. 1.75x9.25 LVL ridge roof sheathing on 2x8 rafters @ max. 24" o.c. 1.75x9.25 LVL hip n o i g n h t a e h s f o o r . c . o " 4 2 . x a m @ s r e t f a r 8 x 2 1.75x9.25 LVL hip hip e g d i r L V L 5 2 . 9 x 5 7 . 1 1.75x9.25 LVL valley 1.75x9.25 LVL hip e g d i r L V L 5 2 . 9 x 5 7 . 1 1.75x9.25 LVL hip 1.75x9.25 LVL hip e g d i r L V L 5 2 9 x 5 7 1 . . 1.75x9.25 LVL hip 1.75x9.25 LVL valley 1.75x9.25 LVL hip S2.4 Roof Framing Legend non-load-bearing stud wall, lower level load-bearing 2x6 stud wall, lower level for reference stud wall, lower level roof bracing . g n i r e e n g n E y f f i u D f o i n o s s m r e p i n e t t i r w s s e r p x e e h t i i g n n a b o t t s r i f t u o h t i w , y t r a p d r i h t a o t d e n g s s a i r o , r e n n a m y n a n i i d e p o c r o d e g n a h c , d e c u d o r p e r e b t o n y a m d n a i g n i r e e n g n E y f f u D f o y t r e p o r p i e r a s g n w a r d e s e h T Austin, Texas (512) 402-0074 Firm Registration No. F-8637 07 oct 2026 PROJECT NUMBER: 26014 CLIENT: Brian and Caroline Haley i e c n e d s e R y e a H l d a o R r o s d n W i t s a E 0 2 2 2 s a x e T , n i t s u A ISSUE: package 0 - for permit 1 - for permit date 14 aug 2026 07 oct 2026 SHEET TITLE: Roof Framing Plan SHEET NUMBER: S2.4 Width of Recess verify with builder min. 8" 1.5" deep recess for garage threshold curb beyond per 'c' 3/4" thick full depth expansion joint driveway flatwork by others thickened to bear on ledge as shown #3 x 18" dowels @ 16" o.c. 5 1/2" lengthen anchor bolt to 7" below slab x a m " 6 reinforce curb w/ continuous #4 horizontal and #4 vertical @ 18" o.c. secured to stirrups : h t p e D m a e B m a e b y f s i t a s o t d e r i u q e r s a t h g e h i l l a w d n a g n i r a e b " 0 - ' 2 m u m n m h t i i i w s t n e m e r i u q e r see detail 'z' for miscellaneous details, drainage requirements and corner details 6 mil poly slip sheet (any required vapor barrier to be specified by others) d n a s s e n k c h t i b a s l n a p l r e p t n e m e c r o f n e r i 6"x6" haunch compacted select fill per notes (depth as req'd) fill to final grade top of slab see Architect for elev existing grade varies bearing strata varies : h t p e D m a e B m a e b y f s i t a s o t d e r i u q e r s a t h g e h i l l a w d n a g n i r a e b beam reinforcement inside stirrup similar to 'a' DEEP beam reinforcement: #4 @ 12" o.c.e.w. both faces : M A E B P E E D e p o s l e t i s h t i w s e i r a v " 0 - ' 2 m u m n m h t i i i w s t n e m e r i u q e r Perimeter @ garage threshold otherwise similar to 'a' 1g Perimeter grade beam @ porch otherwise similar to 'a' 1p Perimeter grade beam w/ curb otherwise similar to 'a' 1c Perimeter DEEP beam w/ no mas otherwise similar to 'a' 1d Perimeter grade beam unless noted otherwise: 3/4" = 1'-0" 1a Beam Bearing: on piers Beam Width minimum 1'-0" Beam Reinforcement: (2) #5 top : (2) #5 bottom: #3 @ 36" o.c stirrups: Fill-side face of wall or beam Add 12" hook to end of each horizontal rebar OR use corner bars same diameter as horizontal rebar w/ 18" legs Fill-side face of wall or beam Add 12" hook to end of each horizontal rebar OR use corner bars same diameter as horizontal rebar w/ 18" legs Locate first stirrup close to intersection Edge of concrete at reentrant corner 1'-8" Locate first stirrup close to intersection Edge of concrete at corner Locate first stirrup close to intersection Edge of concrete at corner T-intersection Exterior Corner Fill-side face of wall or beam Add 12" hook to end of each horizontal rebar OR use corner bars same diameter as horizontal rebar w/ 18" legs Reentrant Corner with no continuous beam Plan Views of Typical Corner Details Stud wall per framing plan and notes 6 mil poly slip sheet (any required vapor barrier to be specified by others) grade beam per other details Final Wall Height 1. Minimum 8" from final grade to top of slab 2. Where Beam Depth exceeds 3'-0", see DEEP beam Swale sloped at min. 2% away from foundation fill to final grade slope final grade at min. 5% to swale top of slab see Architect for elev elevation: t.o.slab elevation: t.o.pier & b.o.grade beam r e v o c " 2 12" 12" 30" (4) #5 (6) #5 vertical #3 ties @ 12" o.c. ) r e e n g n e i y b d e v o r p p a d n a g n i r a e b d e t o n i e v e h c a o t d e r i u q e r s A 3" cover " 6 - ' 1 r e t e m a d i r e p i Reduce slab rebar spacing running into cantilevered slab to #4 @ 8" o.c. and add 6" hook at end Add second mat of rebar 2" from bottom, #4 @ 16" o.c.e.w. " 2 / 1 9 e n o t s e m i l n a t o t n i " 0 - ' 5 r o k c o r e n o t s e m i l o t n i " 0 - ' 3 Beam per 1a S3.0 r e v o c " 3 elevation: bearing . g n i r e e n g n E y f f i u D f o i n o s s m r e p i Typical details for perimeter grade beam 1z Perimeter grade beam w/ cantilever 3/4" = 1'-0" 1h Typical concrete pier 3/4" = 1'-0" 0a n e t t i r w s s e r p x e e h t 1st Pour 2nd Pour form joint w/ keyway extend slab reinforcement 18" through keyway into second pour Detail Notes: use this detail for planned and unplanned interruptions in concrete placement. Typical slab construction joint 8y 1" deep crack control joint tooled during finishing or sawcut per Concrete Crack Control notes reinforcement continuous under joint tread width per Architect concrete steps per plan w/ #3 nosing - typ. top of slab see Architect for elev 1'-0" width of heavily loaded wall per plan " 8 Beam Reinforcement: per detail 'a' riser height per Architect wall reinforcement: #4 @ 12" o.c.e.w. both faces thicken slab to 8" and add #4 @ 12" o.c.e.w. bottom : h t p e D m a e B ' a ' l i a t e d r e p top of slab see Architect for elev t c e t i h c r A r e p l : b a s - n i - p o r d drop in slab per plan and verify w/ Architect (6" max for this detail- see other details for greater drop) top of slab see Architect for elev lengthen anchor bolt to 7" below slab x a m " 6 ) l i a t e d s h t i r o f x a m " 0 - ' 4 ( : h t p e D m a e B " 0 - ' 2 #4 Z-bar at each slab rebar w/ min. 8" legs into upper and lower slabs Beam Reinforcement: (2) #5 top : (2) #5 bottom: #3 @ 36" o.c stirrups: Beam Width minimum 1'-0" 5 1/2" reinforce curb w/ continuous #4 horizontal and #4 vertical @ 18" o.c. secured to stirrups Note: Where fill depth of exceeds 48" inches (measured from bottom of slab at interior beam intersections) install hard point: 12" dia. concrete piers (formed or drilled) through the fill and reinforced with (4) #4 vertical (extend 12" into beam) and #3 ties @ 18" o.c. r e p b a s l n a p l l l i f t c e e s l d e t c a p m o c 0 . 3 S 1 o t r a l i m s i top of slab see Architect for elev : h t p e D m a e B " 0 - ' 2 Austin, Texas (512) 402-0074 Firm Registration No. F-8637 07 oct 2026 PROJECT NUMBER: 26014 CLIENT: Brian and Caroline Haley Beam Width minimum 1'-0" Beam Reinforcement: (2) #5 top : (2) #5 bottom: #3 @ 36" o.c stirrups: Keyway at horizontal construction joint w/ approved waterstop Upper beam similar to 'BASIC BEAM' 2x6 ledger fastened to face of concrete to support edge of floor sheathing. Shim as req'd and nail floor sheathing and floor truss stiffener to ledger. Detail Notes: locate joints per plan and per Concrete Crack Control notes. Typical slab crack control joint 8z Section @ thickened slab 2t Beam Reinforcement: per detail 'a' Beam Width per detail 'a' Interior grade beam @ drop up to 2'-0" 2e otherwise similar to 'a' Interior grade beam @ drop 2d otherwise similar to 'a' Interior grade beam w/ curb 2c otherwise similar to 'a' Interior grade beam 2a i i g n n a b o t t s r i f t u o h t i w , y t r a p d r i h t a o t d e n g s s a i r o , r e n n a m y n a n i i d e p o c r o d e g n a h c , d e c u d o r p e r e b t o n y a m d n a i g n i r e e n g n E y f f u D f o y t r e p o r p i e r a s g n w a r d e s e h T i e c n e d s e R y e a H l d a o R r o s d n W i t s a E 0 2 2 2 s a x e T , n i t s u A ISSUE: package 0 - for permit 1 - for permit date 14 aug 2026 07 oct 2026 SHEET TITLE: Details SHEET NUMBER: S3.0 s s u r t r o o l f " 6 - ' 1 n a p l i g n m a r f r e p top of slab b a s l p o t w o e b l " 4 2 t n o i j e t a c o L o t n o i t c e n n o c e t a t i l i c a f o t . b a s l r e p p u f o s m a e b r o i r e t n i Approx. 2" gap to accommodate tolerances in wall plumbness and straightness Rock cut: Contractor is responsible for stabilizing through construction Wood stud wall per Architect and framing plan Wall reinforcement: Earth side mat: vertical: horizontal: #4 @ 18" o.c. #4 @ 18" o.c. House side mat: vertical: horizontal: #5 @ 18" o.c. #4 @ 18" o.c. wall thickness: 1'-0" ) m u m x a m i " 0 - ' 3 1 ( r e d l i u B / w y f i r e v d n a t c e t i h c r A r e p p o r D #5 dowels @ each vertical rebar extending from bottom of grade beam to 24" into wall Drain pipe per Detail Notes and wrapped in filter fabric w/ flowline minimum 6" below lower slab elevation Keyway at horizontal construction joint w/ waterstop per Detail Notes top of slab Water proofing per Detail Notes Gravel backfill minimum 12" wide w/ protective board against wall waterproofing as req'd. t h p e d M A E B C S A B e e s I " 0 - ' 1 o t d e c u d e r e b y a m t u b k c o r d e b n o n e h w 6"x6" haunch 6 mil poly slip sheet (any required vapor barrier to be specified by others) Slab: thickness and reinforcement per plan continue wall and reinforcement as required by landscape plans top of slab per builder or architect Optional construction joint Wall Reinforcement: Earth side: #4 @ 18" o.c.e.w 1'-0" Exterior side: #4 @ 18" o.c. horizontally #5 @ 9" o.c. vertically Wall Drainage: 1" dia. PVC weep pipes @ 6'-0" o.c. max. and located within 4" above final grade. Extend pipe into bagged gravel back fill. " 0 - ' 2 . n m i d e s u s i t n o i j n o i t c u r t s n o c f i " 0 - ' 8 1 o t " 1 - ' 2 1 s e i r a v : t h g e H i l l a W ) " 0 - ' 8 1 d e e c x e l l i w t h g e h i l l a w f i n o i t c u r t s n o c o t r o i r p r e e n g n E i t c a t n o c ( continue wall and reinforcement as required by landscape plans 6"x6" haunch 6 mil poly slip sheet (any required vapor barrier to be specified by others) top of slab per builder or architect Optional construction joint " 0 - ' 2 . n M i d e s u s i t n o i j n o i t c u r t s n o c f i 1'-0" Wall Reinforcement: #4 @ 18" o.c.e.w both faces Tie every other vertical bar to beam stirrup above. Stop horizontal bars at bottom of beam stirrup. Wall Drainage: 1" dia. PVC weep pipes @ 6'-0" o.c. max. and located within 4" above final grade. Extend pipe into bagged gravel back fill. " 0 - ' 2 1 o t " 1 - ' 3 s e i r a v : t h g e H i l l a W existing grade varies bearing strata varies Min. 6" thick slab measured at inside of tread #3 nosing #4 @ 16" o.c.e.w. Tread width per Architect Riser height per Architect Beam Width 1'-0" similar to '1a' Steps to grade 3/4 = 1'-0" 4s Beam Bearing: on piers per 0a/S3.0 Beam Width minimum 1'-0" Beam Bearing: on piers per 0a/S3.0 Beam Width minimum 1'-0" Lower beam similar to 1a/S3.0 Perimeter grade beam - at steps Unless otherwise noted, all details are 3/4" = 1'-0" 4a Beam width min. 1'-0" Detail Notes: Waterproofing, drains, waterstops, etc. outside the scope of the Structural Engineer. Design or specification of these elements and systems are the responsibility of others and are shown here only for design intent. Drop in slab 3/4" = 1'-0" 3a Where necessary to avoid roof, chamfer web and weld top flange to web " 8 . n m i n i r e e n g n E i t c a t n o c l e e h r e t r o h s f i e c n a v d a t i f o t d e r i u q e r s i t h g e h i f o o r r e d n u Where shown on details and where necessary for wood connections fasten wood blocking to steel flange w/ 1/2" dia. A307 bolts @ 24" o.c. alternating sides of web Where shown on details and where necessary for wood connections fasten wood blocking to steel web w/ 1/2" dia. A307 bolts @ 24" o.c. .75H dia. max. .75H dia. max. H = i t h g e H m a e B Note: See plan for wall orientation relative to beam. 6" min. Steel beam per plan Steel column Wall sheathing fastened to studs Base Plate elevation view t.o.c. 3/16 Steel column per plan Ensure that wood blocking bears tightly against bottom flange Steel base plate below Fasten stud to steel column w/ PAF @ 16" o.c. plan view Base Plate plan view " 5 " 2 / 1 2 " 2 / 1 2 Beam to column connection - bearing 1 1/2" = 1'-0" 2c Blocking fastened to a steel beam 1 1/2" = 1'-0" 2b Penetrations thru steel beam 1 1/2" = 1'-0" 2a Typical stud sandwich at steel column 1 1/2" = 1'-0" 1e Centerline of column Steel column per plan 3/16 1/2" thick base plate Optional:+/-1/2" high-strength grout bed Anchor Rods: (2) 5/8" dia. threaded rod embedded min. 7" and epoxy grouted 6" 4 1/2" 1 1/2" Steel column per plan 1'-0" Steel column base plate 1 1/2" = 1'-0" 1a Austin, Texas (512) 402-0074 Firm Registration No. F-8637 07 oct 2026 PROJECT NUMBER: 26014 CLIENT: Brian and Caroline Haley i e c n e d s e R y e a H l d a o R r o s d n W i t s a E 0 2 2 2 s a x e T , n i t s u A ISSUE: package 0 - for permit 1 - for permit date 14 aug 2026 07 oct 2026 SHEET TITLE: Details SHEET NUMBER: S3.1 . g n i r e e n g n E y f f i u D f o i n o s s m r e p i n e t t i r w s s e r p x e e h t i i g n n a b o t t s r i f t u o h t i w , y t r a p d r i h t a o t d e n g s s a i r o , r e n n a m y n a n i i d e p o c r o d e g n a h c , d e c u d o r p e r e b t o n y a m d n a i g n i r e e n g n E y f f u D f o y t r e p o r p i e r a s g n w a r d e s e h T Braced Wall Line Braced Wall Line e n L i l l a W d e c a r B P S W S C - Braced Wall Line Braced Wall Line e n L i l l a W d e c a r B P S W S C - l l a W d e c a r B e n L i e n L i l l a W d e c a r B e n L i l l a W d e c a r B Braced Wall Line CS-WSP CS-WSP Braced Wall Line B G B G CS-WSP Braced Wall Line l l a W d e c a r B e n L i l l a W d e c a r B e n L i l l a W d e c a r B e n L i Braced Wall Line e n L i l l a W d e c a r B CS-WSP P S W S C - l l a W d e c a r B e n L i e n L i l l a W d e c a r B CS-WSP Braced Wall Line Braced Wall Line Braced Wall Line P S W S C - CS-WSP Braced Wall Line l l a W d e c a r B e n L i BRACING METHODS Designation and Method Material Fasteners Spacing LIB Let-in-bracing Simpson WB, RCW or TWB per manufacturer each stud per manufacturer WSP Wood structural panel 7/16" thick GB Gypsum board 1/2" thick 8d common nails (2.5"x0.131") 1.75" penetration (or 16 gauge 1 1/2" staples 1" penetration) nails or screws per 2024 IRC Table R702.3.5 6" edges, 12" field (3" edge, 6" field) 7" edges, 7" field ABW Alternate braced wall 7/16" thick see 2024 IRC Figure R602.10.6.1 CS-WSP Continuously sheathed 7/16" thick wood structural panel 8d common nails (2.5"x0.131") 1.75" penetration (or 16 gauge 1 1/2" staples 1" penetration) 6" edges, 12" field (3" edge, 6" field) Austin, Texas (512) 402-0074 Firm Registration No. F-8637 07 oct 2026 PROJECT NUMBER: 26014 CLIENT: Brian and Caroline Haley i e c n e d s e R y e a H l d a o R r o s d n W i t s a E 0 2 2 2 s a x e T , n i t s u A Second Floor Bracing Plan 1/4" = 1'-0" plan north ISSUE: package 0 - for permit 1 - for permit date 14 aug 2026 07 oct 2026 SHEET TITLE: Lateral Bracing Plan Second Floor SHEET NUMBER: S4.2 . g n i r e e n g n E y f f i u D f o i n o s s m r e p i n e t t i r w s s e r p x e e h t i i g n n a b o t t s r i f t u o h t i w , y t r a p d r i h t a o t d e n g s s a i r o , r e n n a m y n a n i i d e p o c r o d e g n a h c , d e c u d o r p e r e b t o n y a m d n a i g n i r e e n g n E y f f u D f o y t r e p o r p i e r a s g n w a r d e s e h T Braced Wall Line Braced Wall Line e n L i l l a W d e c a r B l l a w e t e r c n o C l l a W d e c a r B e n L i e n L i l l a W d e c a r B CS-WSP Braced Wall Line P S W S C - P S W S C - Concrete wall Braced Wall Line l l a W d e c a r B e n L i Austin, Texas (512) 402-0074 Firm Registration No. F-8637 07 oct 2026 PROJECT NUMBER: 26014 CLIENT: Brian and Caroline Haley i e c n e d s e R y e a H l d a o R r o s d n W i t s a E 0 2 2 2 s a x e T , n i t s u A First 2" max. from exterior wall intended as braced wall w/ gypsum sheathing sheathing on wall beyond per Architect and not structural imperative Unless noted otherwise, install Simpson H2.5 hurricane ties at every rafter. Wall length and openings per plan V-notch as req'd for ventilation 2x4 or 2x6 studs @ max. 16" o.c. 2x blocking (same size as studs) at edges of sheathing GB - Gypsum sheathing BOTH FACES OF STUD WALL per Bracing Methods Table, S4.0 Fasten interior braced wall sill plate to slab w/ PAF's (minimum shank diameter of 0.177", a minimum length of 3 1/4") at average spacing of 8" with two pins 6" and 10" from each end of each plate. (Optionally, use J-bolts per elevation 1a) . x a m " 0 - ' 8 - d e r i u q e r s a t c e t i h c r A r e p " 0 - ' 8 blocking on wall beyond per Architect and not structural imperative continue PAF's for entire length of wall beyond 2x4 or 2x6 studs @ max. 16" o.c. 2x blocking (same size as studs) at edges of sheathing CS-WSP or CS-FGB Structural sheathing per Bracing Methods Table, S4.0 1/2" dia. J-bolts embedded 7" into slab and spaced @ max. 6'-0" o.c. and located 4" to 12" from each end of each sill plate with min. (2) bolts per sill plate Solid 2x blocking between rafters from to plate to roof sheathing for shear transfer. Nail roof sheathing to blocking w/ 8d @ 6" o.c. and toe nail blocking to top plate w/ 8d @ 6" o.c. . x a m " 0 - ' 8 - d e r i u q e r s a t c e t i h c r A r e p " 0 - ' 8 Elevation @ interior braced wall 1/4" = 1'-0" Full Size; 1/8" = 1'-0" Half Size 1b Elevation @ exterior braced wall 1/4" = 1'-0" Full Size; 1/8" = 1'-0" Half Size 1a BRACING METHODS Designation and Method Material Fasteners Spacing LIB Let-in-bracing Simpson WB, RCW or TWB per manufacturer each stud per manufacturer WSP Wood structural panel 7/16" thick GB Gypsum board 1/2" thick 8d common nails (2.5"x0.131") 1.75" penetration (or 16 gauge 7/16"x1 1/2" staples, 1" penetration) nails or screws per 2024 IRC Table R702.3.5 6" edges, 12" field (3" edge, 6" field) 7" edges, 7" field ABW Alternate braced wall 7/16" thick see 2024 IRC Figure R602.10.6.1 CS-WSP Continuously sheathed 7/16" thick wood structural panel 8d common nails (2.5"x0.131") 1.75" penetration (or 16 gauge 7/16"x1 1/2" staples, 1" penetration) 6" edges, 12" field (3" edge, 6" field) Lower Level Bracing Plan 3/16" = 1'-0" plan north ISSUE: package 0 - for permit 1 - for permit date 14 aug 2026 07 oct 2026 SHEET TITLE: Lateral Bracing Plan SHEET NUMBER: S4.0 . g n i r e e n g n E y f f i u D f o i n o s s m r e p i n e t t i r w s s e r p x e e h t i i g n n a b o t t s r i f t u o h t i w , y t r a p d r i h t a o t d e n g s s a i r o , r e n n a m y n a n i i d e p o c r o d e g n a h c , d e c u d o r p e r e b t o n y a m d n a i g n i r e e n g n E y f f u D f o y t r e p o r p i e r a s g n w a r d e s e h T e n L i l l a W d e c a r B e n L i l l a W d e c a r B e n L i l l a W d e c a r B Braced Wall Line Braced Wall Line e n L i l l a W d e c a r B CS-WSP e n L i l l a W d e c a r B CS-WSP CS-WSP B G P S W S C - Braced Wall Line Braced Wall Line Braced Wall Line Austin, Texas (512) 402-0074 Firm Registration No. F-8637 07 oct 2026 PROJECT NUMBER: 26014 CLIENT: Brian and Caroline Haley P S W S C - P S W S C - Braced Wall Line Braced Wall Line Braced Wall Line P S W S C - l l a W d e c a r B e n L i CS-WSP CS-WSP l l a W d e c a r B e n L i l l a W d e c a r B e n L i Braced Wall Line CS-WSP Braced Wall Line l l a W d e c a r B e n L i l l a W d e c a r B e n L i BRACING METHODS Designation and Method Material Fasteners Spacing LIB Let-in-bracing Simpson WB, RCW or TWB per manufacturer each stud per manufacturer WSP Wood structural panel 7/16" thick GB Gypsum board 1/2" thick 8d common nails (2.5"x0.131") 1.75" penetration (or 16 gauge 1 1/2" staples 1" penetration) nails or screws per 2024 IRC Table R702.3.5 6" edges, 12" field (3" edge, 6" field) 7" edges, 7" field ABW Alternate braced wall 7/16" thick see 2024 IRC Figure R602.10.6.1 CS-WSP Continuously sheathed 7/16" thick wood structural panel 8d common nails (2.5"x0.131") 1.75" penetration (or 16 gauge 1 1/2" staples 1" penetration) 6" edges, 12" field (3" edge, 6" field) Frist Floor Bracing Plan 3/16" = 1'-0" plan north i e c n e d s e R y e a H l d a o R r o s d n W i t s a E 0 2 2 2 s a x e T , n i t s u A ISSUE: package 0 - for permit 1 - for permit date 14 aug 2026 07 oct 2026 SHEET TITLE: Lateral Bracing Plan First Floor SHEET NUMBER: S4.1 Braced Wall Line e n L i l l a W d e c a r B P S W S C - Braced Wall Line CS-WSP l l a W d e c a r B e n L i Braced Wall Line Braced Wall Line e n L i l l a W d e c a r B P S W S C - l l a W d e c a r B e n L i . g n i r e e n g n E y f f i u D f o i n o s s m r e p i n e t t i r w s s e r p x e e h t i i g n n a b o t t s r i f t u o h t i w , y t r a p d r i h t a o t d e n g s s a i r o , r e n n a m y n a n i i d e p o c r o d e g n a h c , d e c u d o r p e r e b t o n y a m d n a i g n i r e e n g n E y f f u D f o y t r e p o r p i e r a s g n w a r d e s e h T