04.0 - 4104 Avenue F — original pdf
Backup
CONCEPT RENDERING PROJECT TEAM OWNER SUSAN AUDETTE 4104 Avenue F AUSTIN, TX 78751 SUSAN AUDETTE 651-260-7040 susan.s.audette@gmail.com ARCHITECT studioHA 2114 E 16th STREET AUSTIN, TEXAS 787052 HOLLY ARTHUR, AIA 512-694-3557 holly@studioha.com ZONING & CODE ANALYSIS LEGAL DESCRIPTION LOT 20-22 BLK 25 HYDE PARK ADDN NO 1 PARCEL ID ZONING BUILDING CODES 0220060513 SF-3-H-HD-NCCD-NP 2024 INTERNATIONAL BUILDING CODE (COA AMMENDMENTS) 2024 INTERNATIONAL MECHANICAL CODE (COA AMMENDMENTS) 2024 INTERNATIONAL PLUMBING CODE (COA AMMENDMENTS) 2023 NATIONAL ELECTRIC CODE (COA AMMENDMENTS) 2024 INTERNATIONAL ENERGY CONSERVATION CODE (COA) BUILDING DESCRIPTION TWO STORY WOOD FRAME, WOOD SIDING RESIDENCE LEGAL JURISDICTION AUSTIN, TEXAS, TRAVIS COUNTY OCCUPANCY CLASSIFICATION GROUP A-2 TYPE OF CONSTRUCTION V-B FIRE SPRINKLER NOT REQUIRED PRELIMINARY NOT FOR CONSTRUCTION This drawing was prepared under the supervision of Holly Arthur. It is not to be used for regulatory approval, permitting, or construction purposes. ISSUED DATE 2026-11-05 PROJECT # 2605 HLC SUBMISSION SYMBOL LEGEND AREA CALCULATIONS FOR REFERENCE ONLY GENERAL NOTES 1. ALL WORK SHALL BE IN CONFORMANCE WITH APPLICABLE BUILDING CODES, AND TO INCLUDE ALL REQUIREMENTS OF OTHER AGENCIES HAVING JURISDICTION. 2. EXAMINATION OF THE SITE AND PORTIONS THEREOF THAT AFFECT THIS WORK SHALL BE MADE BY THE GENERAL CONTRACTOR, WHO SHALL COMPARE EXISTING CONDITIONS WITH THE CONTRACT DOCUMENTS AND SATISFY HIM/HERSELF AS TO THE EXISTING CONDITIONS UNDER WHICH WORK IS TO BE PERFORMED. CONTRACTOR SHALL AT SUCH TIME ASCERTAIN AND VERIFY THE LOCATIONS OF EXISTING STRUCTURES. 3. THE CONTRACT DOCUMENTS DESCRIBE DESIGN INTENT, AND ARE NOT INTENDED TO BE ALL INCLUSIVE. CONTRACTOR IS RESPONSIBLE FOR MEANS AND METHODS TO PROVIDE COMPLETE OPERATIONAL SYSTEMS AND INSTALLATIONS. NO CLAIMS FOR ADDITIONAL WORK WILL BE AWARDED FOR WORK WHICH IS DESCRIBED IN THESE DOCUMENTS OR WHICH IS REASONABLY INFERABLE FROM THEM. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR THOROUGH COORDINATION OF TRADES. ALL CLAIMS FOR ADDITIONAL WORK WILL NOT BE AWARDED FOR ANY AND ALL WORK RELATED TO SUCH COORDINATION. 5. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, AND CONDITIONS AT THE SITE, CONFIRM THAT THE WORK IS BUILDABLE AS SHOWN, AND NOTIFY THE ARCHITECT IN WRITING OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH ANY AND ALL WORK IN QUESTION. 6. ALL DIMENSIONS ARE TO FINISH FACE OF CONCRETE, CENTERLINE OF STEEL, FACE OF STUD OR CASEWORK UNLESS NOTED OTHERWISE. DIMENSIONS NOTED AS "CLR" MUST BE PRECISELY MAINTAINED. DIMENSIONS ARE NOT ADJUSTABLE WITHOUT ARCHITECTS APPROVAL UNLESS NOTED AS "+/-". VERIFY DIMENSIONS MARKED "V.I.F." PRIOR TO COMMENCEMENT OF CONSTRUCTION, AND NOTIFY ARCHITECT OF ANY INCONSISTENCIES. 7. ALL DIMENSIONS, NOTES AND DETAILS SHOWN ON ONE PORTION OF A DRAWING SHALL APPLY TYPICALLY TO ALL OPPOSITEHAND AND/OR CONDITIONS UNLESS OTHERWISE NOTED. 8. "ALIGN" SHALL MEAN TO ACCURATELY LOCATE FINISH FACES IN THE SAME PLANE. 9. THE CONTRACT DOCUMENTS ARE COMPLIMENTARY. WHAT IS SHOWN OR REFERRED TO PARTIALLY OR WHOLE ON ANY SHALL BE PROVIDED AS THOUGH SHOWN ON ALL. 10. DO NOT SCALE DRAWINGS. DIMENSIONS SHALL GOVERN. DRAWINGS AT A LARGE SCALE SHALL TAKE PRECEDENCE OVER DRAWINGS OF A SMALL SCALE. DETAILS SHALL GOVERN OVER PLANS AND ELEVATIONS. 11. CONTRACTOR SHALL VERIFY LAYOUT OF PARTITIONS, DOORS, ELECTRICAL OUTLETS, DATA AND TELEPHONE OUTLETS, LIGHT FIXTURES, AND SWITCHES WITH ARCHITECT PRIOR TO PROCEEDING WITH CONSTRUCTION. CONTRACTOR SHALL VERIFY THAT NO CONFLICTS EXIST IN LOCATIONS OF ANY MECHANICAL, TELEPHONE, DATA, ELECTRICAL, LIGHTING, PLUMBING, AND SPRINKLER EQUIPMENT (TO INCLUDE BUT NOT LIMITED TO ALL PIPING, DUCTWORK AND CONDUIT AND THAT ALL REQUIRED CLEARANCES FOR INSTALLATION AND MAINTENANCE ARE PROVIDED. 12. DAMAGE TO NEW AND EXISTING MATERIALS, FINISHES, STRUCTURES AND EQUIPMENT SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE OWNER AT THE EXPENSE OF THE CONTRACTOR. 13. ALL WORK LISTED, SHOWN OR IMPLIED ON ANY CONTRACT DOCUMENT SHALL BE SUPPLIED AND INSTALLED BY THE CONTRACTOR, EXCEPT WHERE NOTED OTHERWISE. 14. IN CASE OF CONFLICTS BETWEEN ARCHITECT'S AND ENGINEER'S DRAWINGS IN THE LOCATION OF MATERIALS AND/OR EQUIPMENT, ARCHITECTURAL DRAWINGS SHALL GOVERN. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY OF SUCH CONFLICT. 15. ALL MANUFACTURED ARTICLES, MATERIALS AND EQUIPMENT SHALL BE INSTALLED, CONNECTED, ERECTED CLEANED, AND CONDITIONED PER THE MANUFACTURER'S INSTRUCTIONS. IN CASE OF DIFFERENCES BETWEEN MANUFACTURER'S INSTRUCTIONS AND THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT BEFORE PROCEEDING WITH THE WORK IN QUESTION. 16. ALL WORK NOTED AS "BY OTHERS" OR "N.I.C." SHALL BE PROVIDED BY OWNER OR UNDER SEPARATE CONTRACT. SUBMIT TO THE ARCHITECT AND OWNER SCHEDULE REQUIREMENTS FOR THIS "OTHER" WORK IN THE CONSTRUCTION PROGRESS SCHEDULE AND COORDINATE AS REQUIRED TO ASSURE ORDERLY SEQUENCE OF INSTALLATION. 17. THE CONTRACTOR SHALL REMOVE ALL RUBBISH AND WASTE MATERIALS OF ALL SUBCONTRACTORS AND TRADES ON A DAILY BASIS AND SHALL EXERCISE STRICT CONTROL OVER JOB CLEANING TO PREVENT ANY DIRT, DEBRIS, OR DUST FROM AFFECTING ANY FINISHED AREAS IN OR OUTSIDE THE JOB SITE. BURNING OF DEBRIS ON SITE SHALL NOT BE PERMITTED. 18. CONTRACTOR SHALL NOT PROCEED WITH ANY WORK REQUIRING ADDITIONAL COMPENSATION BEYOND THE CONTRACT AMOUNT WITHOUT AUTHORIZATION FROM THE ARCHITECT OR OWNER'S REPRESENTATIVE. FAILURE TO OBTAIN AUTHORIZATION SHALL INVALIDATE ANY CLAIM FOR ADDITIONAL COMPENSATION. AVENUE F M A 3 2 : 3 3 : 1 1 6 2 0 2 / 5 1 1 / | 1 / A3.0 ELEVATION ROOM NAME 1.01 ROOM NAME NUMBER AREA 1 A3.0 1 A3.0 1 A3.0 1 A3.0 BUILDING SECTION WALL SECTION SECTION DETAIL DETAIL 1.01 1.01 A1 A TA-1 DOOR NUMBER WINDOW TYPE PARTITION TYPE PLUMBING FIXTURE TYPE TOILET ACCESSORY TYPE VICINITY MAP 4104 AVENUE F AUSTIN, TX 78751 TRUE NORTH DRAWING INDEX ARCHITECTURAL G1.0 G1.2 A0.2 A1.1 A1.2 A1.3 A2.0 A2.1 A2.3 A7.0 COVER SHEET EXISTING PHOTOS SITE PLAN FIRST FLOOR PLAN SECOND FLOOR PLAN ROOF PLAN EXTERIOR ELEVATIONS EXTERIOR ELEVATIONS EXTERIOR ELEVATIONS PERSPECTIVES A H o d u i t s © PROJECT AVENUE F 4104 AVENUE F AUSTIN, TX 78751 G1.0 COVER SHEET 496 F F F F F F F F S 60° 00' 00" E 124'-10 51/256" F F POWER POLE P STORAGE 5' SIDE YARD SETBACK P P K C A B T E S R A E R ' 0 1 ELECTRICAL METER A/C PAD P A/C PAD A/C PAD EQ EQ 498 F F F F K C A B T E S D R A Y T N O R F ' 5 2 PROPERTY LINE " 0 - ' 2 1092 " 4 / 1 8 - ' 4 " 4 / 1 0 - ' 4 497 P P P P P P P P P P P P P M A 0 3 : 3 3 : 1 1 6 2 0 2 / 5 1 1 / | i A H o d u t s © " 6 5 2 / 5 2 2 1 1 - ' 4 7 E " 8 5 ' 7 5 ° 9 2 N I E N L Y T R E P O R P Y E L L A " 4 - ' 3 2 " 7 E C N A R A E L C L A C R T C E L E I ' 5 1 EDGE OF GRAVEL CONC. DRIVE STO. 05 GYM 04 4 113/256" 20'-10" 15'-0 93/256" 18'-0" 5' SIDE YARD SETBACK N 60° 02' 40" W 125'-0" PROPERTY LINE 1 SITE PLAN 3/16" = 1'-0" 2420 PROJECT NORTH TRUE NORTH TREE LEGEND TAG SIZE/TYPE 496 11",14" MAGNOLIA 497 61" PECAN 498 27" PECAN 2420 37" PECAN 2421 20" OAK GENERAL NOTES TREE PROTECTION NOTES SITE LEGEND 1. TOPOGRAPHY SHOWS EXISTING GRADE. NEW GRADING TO BE COORDINATED WITH LANDSCAPE. 2. REFER TO PERMIT NUMBER 2019-056726 PR FOR DEMOLITION PERMIT APPLICATION 3. NEW WATER METER AND TAP. RE: CIVIL 4. REFER TO FLOOR PLANS FOR VISITABILITY INFORMATION. 5. GC TO VERIFY LOCATION OF GAS LINE AND GAS METER WITH TEXAS GAS. SITE INFORMATION SITE INFORMATION TAKEN FROM SURVEY PERFORMED BY MICAHEL TURNER PROFESSIONAL LAND SURVEYOR #6441 ON 10/07/20 1. PROVIDE TREE PROTECTION FENCING PER CITY OF AUSTIN REQUIREMENTS AND 8" MULCH GROUND COVER DURING CONSTRUCTION AROUND ALL TREES IN THE CONSTRUCTION AREA. 2. PROVIDE BREATHABLE RUBBER MAT OVER 8" MULCH AT LOCATIONS WHERE TREE PROTECTION FENCING IS NOT POSSIBLE. 3. WRAP 2x4 BOARDS AROUND TREE TRUNKS DURING CONSTRUCTION. 4. ALL LIMBS AND TREE TRIMMING TO BE PERFORMED BY OWNER PROVED ARBORIST. 5. GC TO ENSURE THAT ANY CONCRETE WASHOUT DOES NOT HAPPEN WITHIN THE CRZ OF ANY PROTECTED TREES. 6.GC TO AVOID TRENCHING INSIDE THE 1/2 CRZ OF ANY PROTECTED TREES. 7.IF HEAVY EQUIPMENT WILL BE ROLLING OVER ANY AREA OF THE FULL CRZ OF PROTECTED TREES, PROVIDE 3/4" PLYWOOD OVER 2X4 LUMBER OVER 12″ LAYER OF MULCH TO BRIDGE OVER THE ROOTS AND PREVENT SOIL/ROOT COMPACTION. AFTER CONSTRUCTION IS COMPLETED, SPREAD MULCH AROUND SITE TO LEAVE A MAX LAYER OF 3″ WITHIN ROOT ZONES. CONCRETE FLATWORK X X X 5' TALL TEMPORARY CHAIN LINK FENCE CRZ 1/2 1/4 F F F FENCE P P P POWER LINE G G G GAS LINE EXISTING TREE TO REMAIN 8" LAYER OF MULCH OVER CRZ OF TREES A0.2 SITE PLAN CONSTRUCTION STAGING TO REMAIN FOR DURATION OF CONSTRUCTION ONLY VISITABILITY ROUTE F F F F F F F F F F F F S 2 9 ° 5 1 ' 1 2 " W 7 4 ' - 1 0 2 0 5 / 2 5 6 " F P R O P E R T Y L I N E F F F F CONC. CURB PRELIMINARY NOT FOR CONSTRUCTION This drawing was prepared under the supervision of Holly Arthur. It is not to be used for regulatory approval, permitting, or construction purposes. ISSUED DATE 2026-11-05 PROJECT # 2605 HLC SUBMISSION Y A W K L A W . C N O C WATER METER 2421 F E U N E V A PROJECT AVENUE F 4104 AVENUE F AUSTIN, TX 78751 2 / A2.1 " 0 - ' 2 " 4 - ' 2 " 4 - ' 2 0 . 4 A / 8 EQ EQ 498 BUTLER'S PANTRY 02 POWDER 03 1092 8'-10 1/4" KITCHEN 01 3'-9 1/8" " 8 / 7 1 - ' 7 1'-7" 5 / A4.0 " 8 / 3 5 - ' 3 . 1 2 A / 1 2 . 4 A / 1 2 / A4.2 4 / A4.2 2 . 4 A / 3 2 / A2.0 497 . 0 2 A / 1 1 / A2.3 10' X 40" 2 / A2.3 M A 4 3 : 3 3 : 1 1 6 2 0 2 / 5 1 1 / | i A H o d u t s © GYM 04 STO. 05 1 FIRST FLOOR PLAN 1/4" = 1'-0" PROJECT NORTH TRUE NORTH PLAN LEGEND EXISTING CONSTRUCTION TO REMAIN NEW CONSTRUCTION WOOD FLOORING WOOD DECKING TILE FLOORING CONCRETE FLOORING CARPET A1.1 FIRST FLOOR PLAN PRELIMINARY NOT FOR CONSTRUCTION This drawing was prepared under the supervision of Holly Arthur. It is not to be used for regulatory approval, permitting, or construction purposes. ISSUED DATE 2026-11-05 PROJECT # 2605 HLC SUBMISSION PROJECT AVENUE F 4104 AVENUE F AUSTIN, TX 78751 PRELIMINARY NOT FOR CONSTRUCTION This drawing was prepared under the supervision of Holly Arthur. It is not to be used for regulatory approval, permitting, or construction purposes. ISSUED DATE 2026-11-05 PROJECT # 2605 HLC SUBMISSION PROJECT AVENUE F 4104 AVENUE F AUSTIN, TX 78751 RIDGE 1 SECOND FLOOR PLAN 1/4" = 1'-0" PROJECT NORTH TRUE NORTH PLAN LEGEND EXISTING CONSTRUCTION TO REMAIN NEW CONSTRUCTION WOOD FLOORING WOOD DECKING TILE FLOORING CONCRETE FLOORING CARPET A1.2 SECOND FLOOR PLAN VALLEY E G D R I HIP HIP RIDGE HIP HIP HIP M A 6 4 : 3 3 : 1 1 6 2 0 2 / 5 1 1 / | i A H o d u t s © 498 VALLEY RIDGE VALLEY VALLEY E G D R I HIP HIP 1 . 2 A / 1 HIP HIP NEW SKYLIGHT GUTTERS TPO ROOF 2 / A2.1 VALLEY V A L L E Y VALLEY E G D R I VALLEY RIDGE RIDGE VALLEY E G D R I Y ALLE V HIP HIP 2 / A2.0 497 0 . 2 A / 1 HIP " 0 - ' 1 / " 2 1 / WOOD BEAMS 1/2" / 1'-0" RIDGE HIP " 0 - ' 1 / " 2 / 1 STEEL AWNING GUTTERS SHINGLE ROOF RIDGE " 0 - ' 1 / " 0 1 " 0 - ' 1 / " 0 1 M A 9 5 : 3 3 : 1 1 6 2 0 2 / 5 1 1 / | i A H o d u t s © 1 ROOF PLAN 1/4" = 1'-0" PROJECT NORTH TRUE NORTH ROOF LEGEND GUTTERS ASPHALT SHINGLES CONCRETE PRELIMINARY NOT FOR CONSTRUCTION This drawing was prepared under the supervision of Holly Arthur. It is not to be used for regulatory approval, permitting, or construction purposes. ISSUED DATE 2026-11-05 PROJECT # 2605 HLC SUBMISSION PROJECT AVENUE F 4104 AVENUE F AUSTIN, TX 78751 A1.3 ROOF PLAN NEW SKYLIGHT 2019 ADDITION 2003 ADDITION ORIGINAL 1892 VICTORIAN 2 SOUTH ELEVATION - MAIN HOUSE 1/4" = 1'-0" DOOR AND TRANSOM TO BE REMOVED ADD WOOD SIDING TO MATCH EXIST. SAVE DOOR FOR POSSIBLE REUSE M A 2 0 : 4 3 : 1 1 6 2 0 2 / 5 1 1 / | i A H o d u t s © SHINGLE ROOF WOOD LAP SIDING TO MATCH HOUSE CARPORT ROOF PLATE 108'-4" " 8 - ' 9 CARPORT 98'-8" STEEL AWNING WOOD BEAMS AND COLUMNS " 0 - ' 6 NEW ACCESSORY STRUCTURE AND CARPORT 1 EAST ELEVATION - OVERALL 1/4" = 1'-0" PRELIMINARY NOT FOR CONSTRUCTION This drawing was prepared under the supervision of Holly Arthur. It is not to be used for regulatory approval, permitting, or construction purposes. ISSUED DATE 2026-11-05 PROJECT # 2605 HLC SUBMISSION ROOF PLATE 121'-4" SECOND FLOOR 111'-0" FIRST FLOOR 100'-0" ROOF PLATE 121'-4" SECOND FLOOR 111'-0" PROJECT AVENUE F 4104 AVENUE F AUSTIN, TX 78751 FIRST FLOOR 100'-0" A2.0 EXTERIOR ELEVATIONS PRELIMINARY NOT FOR CONSTRUCTION This drawing was prepared under the supervision of Holly Arthur. It is not to be used for regulatory approval, permitting, or construction purposes. ISSUED DATE 2026-11-05 PROJECT # 2605 HLC SUBMISSION ROOF PLATE 121'-4" SECOND FLOOR 111'-0" FIRST FLOOR 100'-0" ORIGINAL 1892 VICTORIAN 2003 ADDITION 2019 ADDITION 2 NORTH ELEVATION - MAIN HOUSE 1/4" = 1'-0" WINDOW TO BE REMOVED, ADD WOOD SIDING TO MATCH EXIST. NEW WINDOWS, TRIM TO MATCH ESITING WINDOW TO BE REMOVED, ADD WOOD SIDING TO MATCH EXIST. TREE LINE 129'-4" ROOF PLATE 121'-4" SECOND FLOOR 111'-0" OUTLINE OF OLD WINDOW TO BE REMOVED NEW WINDOW, TRIM TO MATCH EXISTING FIRST FLOOR 100'-0" 1 WEST ELEVATION - OVERALL 1/4" = 1'-0" WINDOWS TO BE REMOVED, ADD WOOD SIDING TO MATCH EXIST. M A 3 0 : 4 3 : 1 1 6 2 0 2 / 5 1 1 / | i A H o d u t s © PROJECT AVENUE F 4104 AVENUE F AUSTIN, TX 78751 WOOD SCREEN CARPORT ROOF PLATE 108'-4" WOOD COLUMNS AND BEAMS " 8 - ' 9 " 0 - ' 6 CARPORT 98'-8" A2.1 EXTERIOR ELEVATIONS PRELIMINARY NOT FOR CONSTRUCTION This drawing was prepared under the supervision of Holly Arthur. It is not to be used for regulatory approval, permitting, or construction purposes. ISSUED DATE 2026-11-05 PROJECT # 2605 HLC SUBMISSION PROJECT AVENUE F 4104 AVENUE F AUSTIN, TX 78751 A7.0 PERSPECTIVES 3 CARPORT PERSPECTIVE 3 2 CARPORT PERSPECTIVE 2 1 CARPORT PERSPECTIVE 1 M A 5 0 : 4 3 : 1 1 6 2 0 2 / 5 1 1 / | i A H o d u t s © SIDE - SOUTH SIDE - SOUTH FRONT - SOUTH FRONT - EAST REAR - SOUTHWEST M A 8 0 : 4 3 : 1 1 6 2 0 2 / 5 1 1 / | i A H o d u t s © SIDE - NORTH SIDE - NORTH REAR - SOUTH PRELIMINARY NOT FOR CONSTRUCTION This drawing was prepared under the supervision of Holly Arthur. It is not to be used for regulatory approval, permitting, or construction purposes. ISSUED DATE 2026-11-05 PROJECT # 2605 HLC SUBMISSION PROJECT AVENUE F 4104 AVENUE F AUSTIN, TX 78751 G1.2 EXISTING PHOTOS