Historic Landmark CommissionJune 3, 2026

0.0 - Public Communications - 916 Congress Ave presentation — original pdf

Backup
Thumbnail of the first page of the PDF
Page 1 of 6 pages

P O N M L K J I 1 2 3 4 5 FROM WHICH A CHISLED "X" FOUND BEARS: S38°05'24"E A DISTANCE OF 0.89' 9 13 6 2 2 COPPER 1/2" SERVICE LINE EX. DOMESTIC WATER FOOD TRUCK ONLY IN OPERATION AND PRESENT DURING EVENTS EX. HOSE BIB EX. ELECTRICAL SERVICE X2 METERS ASPHALT DRIVEWAY CONCRETE 3/4" COPPER SERVICE LINE EDGE OF CONCRETE A-3-01 I10 H EXISTING 5/8" WM WV EMH TBOX 14 G F E D C B A 7 8 9 10 11 12 13 14 15 16 17 18 19 20 SITE PLAN LEGEND STAIRS PROPERTY LINE MARK HART ARCHITECTURE 2007 S. 1st Street, Suite 101 Austin, TX 78704 +1.512/910.7057 www.markhartarch.com EXISTING SERVICE SINK EXISTING SINGLE USE RESTROOM 1 EXISTING SINGLE USE RESTROOM 2 LONGEST DISTANCE TO FURTHEST RESTROOM 166'-5" 920 CONGRESS 1 5 0.7' 12 2 DRINKING FOUNTAIN XXX.XX' FINISH FLOOR ELEVATION 2 SECURITY FENCE PATH TO AVAILABLE RESTROOMS SITE PLAN KEY NOTE LEGEND 1 2 3 4 5 6 7 8 9 10 11 12 13 14 EXISTING BOLLARDS EXISTING STAIRS PER IEBC 306.7.2 EXISTING STRUCTURAL REINFORCEMENT TO EXTERIOR WALL PERMIT# 2025-001439 BP EXISTING COURTYARD LIGHTING ELECTRIC PANEL PERMIT# 2025-043567 EP EXISTING FOOD TRUCK ELECTRIC PANEL PERMIT# 2025-043567 EP EXISTING LIGHTING PERMIT# 2025-043567 EP EXISTING GRAVEL EXISTING BRICK PAVERS EXISTING HOSE BIB ANTIQUE WOOD TRIFOLD DOOR WITH TRANSOM ELEVATED WOOD DECK STEEL SECURITY FENCE FOOD TRUCK PICNIC TABLES FEMALE RESTROOM 4 11 MALE RESTROOM 918 CONGRESS 7 6 8 13'-3 1/2" KNOX BOX LOT 5 1'-7 1/2" EX. HOSE BIB 0" LOT 4 914 CONGRESS AVENUE 3 9 0.6' 7 (PARTIALLY DEMOLISHED) 2 - STORY STONE BUILDING FACE OF WALL E K T L E A R W C E N SID O C CO KNOX BOX 3 12 GM 10 FACE OF WALL 6 3 2 - STORY STONE BUILDING FROM WHICH A CHISLED "X" FOUND BEARS: S38°35'24"W A DISTANCE OF 0.96' GAS RISER WITH VALVE ABANDONED 4" SANITARY DRAIN CAPPED AT PROPERTY LINE FROM WHICH A CHISLED "X" FOUND BEARS: N29°07'35"W A DISTANCE OF 0.50' CO GV 12 3 E K T L E A R W C E N SID O C 2 - STORY STONE BUILDING GISTERED ARCHIT ARKW.HA RT M E C T E R TS AT SA 20562 XETE FO EXP: 2026-01-31 03/25/2026 CLIENT: LEE ACKERLEY AUSTIN, TX PROJECT NUMBER: Project Number PROJECT STATUS: PERMIT COMMENT RESPONSE 1 Copyright © 2025 by Mark Hart Architecture, INC. All rights reserved. The arrangements depicted herein are the sole property of Mark Hart Architecture, INC. and may not be reproduced in any form without written permission. E V A S S E R G N O C 6 1 9 1 0 7 8 7 X T N T S U A I . E V A S S E R G N O C 6 1 9 E T A D 6 2 - 5 2 - 3 I I N O T P R C S E D T N E M M O C T M R E P I 1 E S N O P S E R : I S N O S V E R I FOR CITY OF AUSTIN USE ONLY DRAWN BY: # 2 JGL CHECKED BY: Checker DESIGNED BY: Designer ISSUE DATE: 03/25/2026 SHEET: 19 20 AS-1-01 N A L P E T S I A1 SITE PLAN 1" = 5'-0" 1" = 5'-0" 3.13 ft 6.25 ft 12.5 ft 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 N 25 ft 18 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 P O N M L K J I H G F E D C B A EXISTING STORAGE 4'-8 7/8" A16/ A-1-01 " 8 4 x " 0 3 A1 1 0 - 1 - A / 6 A " 0 6 x " 9 5 " 0 6 x " 6 3 A2 B2 FEMALE RESTROOM A1/ A-1-01 " 8 4 x " 0 3 6'-9 1/2" 7'-3 3/8" A2 A1 " 6 - ' 1 / " 2 1 5 - ' 2 " 2 - ' 2 1 " 8 4 x " 0 3 1 0 - 1 - A / 0 1 A " 0 6 x " 9 5 " 8 4 x " 0 3 A13/ A-1-01 MALE RESTROOM B2 " 0 - ' 2 916 CONGRESS E1 CONSTRUCTION PLAN - LEVEL 1 1/4" = 1'-0" 2'-7 7/8" CL 2'-10 7/8" " 2 - ' 1 " 6 " 1 1 - ' 3 " 0 - ' 9 " 0 1 - ' 7 X A M " 0 4 X A M " 4 3 I N M " 9 2'-7 7/8" 4'-3 3/8" 6'-9 1/2" CL L12 A-5-01 L17 A-5-01 L8 A-5-01 L4 A-5-01 L1 A-5-01 G4 A-5-01 LEVEL 1 0" EXISTING STORAGE EXISTING RESTROOM 1 EXISTING RESTROOM 2 920 CONGRESS 916 CONGRESS K1 EXTERIOR WALL SECTION - OPENING IN PARTY WALL 3/8" = 1'-0" S S E R G N O C 6 1 9 J5 DEMOLITION PLAN - LEVEL 1 1/4" = 1'-0" 920 CONGRESS 920 CONGRESS 1/4" = 1'-0" 2.5 ft 5 ft 10 ft 20 ft N Hardie - V-Groove 9'-0" A.F.F. 27'-9 1/4" 4'-5 1/2" 4'-5 1/2" 5'-1 1/8" " 2 / 1 5 - ' 2 B1 1 B % 2 B1 B1 K1 A-1-01 EXISTING STORAGE 2'-7" 6'-1 3/4" 5'-0" Q E Q E Q E Q E FEMALE RESTROOM TYPE C - GWB 9'-0" A.F.F. RE: ELEVATION FOR MOUNTING LOCATION ACCESS HATCH VERIFY HATCH LOCATION MALE RESTROOM TYPE C - GWB 9'-0" A.F.F. 916 CONGRESS E9 REFLECTED CEILING PLAN - LEVEL 1 1/4" = 1'-0" 54" 12" MAX 42" MIN 54" 42" MIN 12" MAX 36" MIN 24" MIN 12" MIN " 0 - ' 5 " 0 - ' 4 X A M " 6 3 - I N M " 3 3 " 0 - ' 9 " 0 - ' 9 " 0 - ' 5 " 0 - ' 4 X A M " 6 3 - I N M " 3 3 " 0 - ' 9 " 0 - ' 5 " 0 - ' 4 X A M " 6 3 - I N M " 3 3 36" MIN 12" MIN 24" MIN " 0 - ' 9 " 0 - ' 5 " 0 - ' 4 X A M " 6 3 - I N M " 3 3 2'-4 1/2" CL 2'-1 3/8" " 2 - ' 1 " 6 " 1 1 - ' 3 " 0 - ' 9 " 0 1 - ' 7 X A M " 0 4 X A M " 4 3 X A M " 7 2 I N M " 9 8'-1 7/8" X A M " 7 1 3'-5 1/2" 2'-1 3/8" CL DEMOLITION PLAN LEGEND EXISTING PARTY WALL TO REMAIN EXISTING FRAMED WALL TO REMAIN EXISTING WALL TO BE REMOVED MARK HART ARCHITECTURE 2007 S. 1st Street, Suite 101 Austin, TX 78704 +1.512/910.7057 www.markhartarch.com PROGRESS PRINT FOR INTERIM REVIEW ONLY. NOT INTENDED FOR BIDDING, PERMIT, OR CONSTRUCTION. REGISTRANTS NAME: MARK HART TEXAS REGISTRATION NUMBER: 20562 05-11-2026 CLIENT: LEE ACKERLEY AUSTIN, TX PROJECT NUMBER: Project Number PROJECT STATUS: PERMIT COMMENT RESPONSE 1 Copyright © 2025 by Mark Hart Architecture, INC. All rights reserved. The arrangements depicted herein are the sole property of Mark Hart Architecture, INC. and may not be reproduced in any form without written permission. GENERAL NOTES - FLOOR PLAN 1. THE INSIDE FACE OF DOOR JAMBS IS TO BE LOCATED 6 INCHES FROM AN INSIDE CORNER UNLESS NOTED OR SHOWN OTHERWISE. 2. DIMENSIONS ARE LOCATED ON CONSTRUCTION PLANS. ALL DIMENSIONS ARE TO THE CENTER OF PARTITIONS AT NON-PRESCIENT PARTITIONS USE GROUP / CONSTRUCTION TYPE GROUP A2 / TYPE VB CONSTRUCTION / SPRINKLED NFPA SPRINKLER NOTE THE STATE OF TEXAS LICENSED CONTRACTOR MUST SUBMIT SHOP DRAWINGS TO THE TRAVIS COUNTY ESD NO. 12 FOR REVIEW AND APPROVAL AFTER THE BUILDING PERMIT IS APPROVED. THESE SHOP DRAWINGS MUST BE APPROVED BY THE TRAVIS COUNTY ESD NO. 12 PRIOR TO THE CONTRACTOR BEGINNING THE WORK, UNLESS OTHERWISE APPROVED. WALL LEGEND A1 A2 B1 INT - 3 1/2" WOOD STUD - PARTITION WALL RE: INT - 5 1/2" WOOD STUD - PARTITION WALL RE: EXT - 5 1/2" WOOD STUD - PARTITION WALL RE: INT - EXISTING PARTITION WALL EXT - EXISTING PARTY WALL CONSTRUCTION PLAN KEY NOTE LEGEND E V A S S E R G N O C 8 1 9 1 0 7 8 7 X T N T S U A I . E V A S S E R G N O C 8 1 9 E T A D I I N O T P R C S E D : I S N O S V E R I FOR CITY OF AUSTIN USE ONLY DRAWN BY: # 1 L E V E L - P C R & N A L P R O O L F JGL CHECKED BY: Checker DESIGNED BY: Designer ISSUE DATE: 05-11-2026 SHEET: A-1-01 A1 ELEVATION - FEMALE RR - SOUTH 3/8" = 1'-0" A6 ELEVATION - FEMALE RR - WEST 3/8" = 1'-0" A10 ELEVATION - MALE RR - WEST 3/8" = 1'-0" A13 ELEVATION - MALE RR - NORTH 3/8" = 1'-0" A16 ELEVATION - DRINKING FOUNTAIN 3/8" = 1'-0" 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 P O N M L K J I H G F E D C B A 918 CONGRESS J1 DEMOLITION PLAN - LEVEL 1 1/4" = 1'-0" 1/4" = 1'-0" 2.5 ft 5 ft 10 ft 20 ft N EXISTING SERVICE SINK EXISTING SINGLE USE RESTROOM 1 EXISTING SINGLE USE RESTROOM 2 918 CONGRESS GENERAL NOTES - FLOOR PLAN 1. THE INSIDE FACE OF DOOR JAMBS IS TO BE LOCATED 6 INCHES FROM AN INSIDE CORNER UNLESS NOTED OR SHOWN OTHERWISE. 2. DIMENSIONS ARE LOCATED ON CONSTRUCTION PLANS. ALL DIMENSIONS ARE TO THE CENTER OF PARTITIONS AT NON-PRESCIENT PARTITIONS USE GROUP / CONSTRUCTION TYPE GROUP A2 / TYPE VB CONSTRUCTION / SPRINKLED NFPA SPRINKLER NOTE THE STATE OF TEXAS LICENSED CONTRACTOR MUST SUBMIT SHOP DRAWINGS TO THE TRAVIS COUNTY ESD NO. 12 FOR REVIEW AND APPROVAL AFTER THE BUILDING PERMIT IS APPROVED. THESE SHOP DRAWINGS MUST BE APPROVED BY THE TRAVIS COUNTY ESD NO. 12 PRIOR TO THE CONTRACTOR BEGINNING THE WORK, UNLESS OTHERWISE APPROVED. MARK HART ARCHITECTURE 2007 S. 1st Street, Suite 101 Austin, TX 78704 +1.512/910.7057 www.markhartarch.com PROGRESS PRINT FOR INTERIM REVIEW ONLY. NOT INTENDED FOR BIDDING, PERMIT, OR CONSTRUCTION. REGISTRANTS NAME: MARK HART TEXAS REGISTRATION NUMBER: 20562 05-11-2026 CLIENT: LEE ACKERLEY AUSTIN, TX CONSTRUCTION PLAN KEY NOTE LEGEND PROJECT NUMBER: Project Number PROJECT STATUS: PERMIT COMMENT RESPONSE 1 Copyright © 2025 by Mark Hart Architecture, INC. All rights reserved. The arrangements depicted herein are the sole property of Mark Hart Architecture, INC. and may not be reproduced in any form without written permission. E V A S S E R G N O C 0 2 9 1 0 7 8 7 X T N T S U A I . E V A S S E R G N O C 0 2 9 E T A D I I N O T P R C S E D : I S N O S V E R I A1 CONSTRUCTION PLAN - LEVEL 1 1/4" = 1'-0" 1/4" = 1'-0" 2.5 ft 5 ft 10 ft 20 ft 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 N 17 18 19 20 JGL CHECKED BY: Checker DESIGNED BY: Designer ISSUE DATE: 05-11-2026 SHEET: A-1-01 FOR CITY OF AUSTIN USE ONLY DRAWN BY: # 1 L E V E L - N A L P R O O L F