Historic Landmark CommissionDec. 3, 2025

05.2 - 2406 E Martin Luther King Jr Blvd - Inspection Report — original pdf

Backup
Thumbnail of the first page of the PDF
Page 1 of 39 pages

Inspection Report Dmitry Dubrovsky Property Address: 2406 E Martin Luther King Jr Blvd Austin TX 78702 2406 E Martin Luther King Jr Blvd Princess Quality inspection John Garza Texas License #25098 505 E Stassney Lane unit 1616, Austin Texas 78745 PROPERTY INSPECTION REPORT FORM Dmitry Dubrovsky Name of Client 2406 E Martin Luther King Jr Blvd, Austin, TX 78702 Address of Inspected Property John Garza Name of Inspector 10/23/2025 Date of Inspection Texas License #25098 TREC License # Name of Sponsor (if applicable) TREC License # PURPOSE OF INSPECTION A real estate inspection is a visual survey of a structure and a basic performance evaluation of the systems and components of a building. It provides information regarding the general condition of a residence at the time the inspection was conducted. It is important that you carefully read ALL of this information. Ask the inspector to clarify any items or comments that are unclear. RESPONSIBILTY OF THE INSPECTOR This inspection is governed by the Texas Real Estate Commission (TREC) Standards of Practice (SOPs), which dictates the minimum requirements for a real estate inspection. The inspector IS required to: • use this Property Inspection Report form for the inspection; • • • inspect only those components and conditions that are present, visible, and accessible at the time of the inspection; indicate whether each item was inspected, not inspected, or not present; indicate an item as Deficient (D) if a condition exists that adversely and materially affects the performance of a system or component OR constitutes a hazard to life, limb or property as specified by the SOPs; and • explain the inspector’s findings in the corresponding section in the body of the report form. The inspector IS NOT required to: identify all potential hazards; turn on decommissioned equipment, systems, utilities, or apply an open flame or light a pilot to operate any appliance; • • • climb over obstacles, move furnishings or stored items; • prioritize or emphasize the importance of one deficiency over another; • provide follow-up services to verify that proper repairs have been made; or • inspect system or component listed under the optional section of the SOPs (22 TAC 535.233). RESPONSIBILTY OF THE CLIENT While items identified as Deficient (D) in an inspection report DO NOT obligate any party to make repairs or take other actions, in the event that any further evaluations are needed, it is the responsibility of the client to obtain further evaluations and/or cost estimates from qualified service professionals regarding any items reported as Deficient (D). It is recommended that any further evaluations and/or cost estimates take place prior to the expiration of any contractual time limitations, such as option periods. Please Note: Evaluations performed by service professionals in response to items reported as Deficient (D) on the report may lead to the discovery of additional deficiencies that were not present, visible, or accessible at the time of the inspection. Any repairs made after the date of the inspection may render information contained in this report obsolete or invalid. REPORT LIMITATIONS This report is provided for the benefit of the named client and is based on observations made by the named inspector on the date the inspection was performed (indicated above). ONLY those items specifically noted as being inspected on the report were inspected. This inspection IS NOT: • a technically exhaustive inspection of the structure, its systems, or its components and may not reveal all deficiencies; • an inspection to verify compliance with any building codes; • an inspection to verify compliance with manufacturer’s installation instructions for any system or component and DOES NOT imply insurability or warrantability of the structure or its components. REI 7-5 (05/04/2015) Page 2 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd NOTICE CONCERNING HAZARDOUS CONDITIONS, DEFICIENCIES, AND CONTRACTUAL AGREEMENTS Conditions may be present in your home that did not violate building codes or common practices in effect when the home was constructed but are considered hazardous by today’s standards. Such conditions that were part of the home prior to the adoption of any current codes prohibiting them may not be required to be updated to meet current code requirements. However, if it can be reasonably determined that they are present at the time of the inspection, the potential for injury or property loss from these conditions is significant enough to require inspectors to report them as Deficient (D). Examples of such hazardous conditions include: • malfunctioning, improperly installed, or missing ground fault circuit protection (GFCI) devices and arc-fault devices; • ordinary glass in locations where modern construction techniques call for safety glass; • malfunctioning or lack of fire safety features such as smoke alarms, fire-rated doors in certain locations, and functional emergency escape and rescue openings in bedrooms; • malfunctioning carbon monoxide alarms; • excessive spacing between balusters on stairways and porches; • • • • improperly installed appliances; improperly installed or defective safety devices; lack of electrical bonding and grounding; and lack of bonding on gas piping, including corrugated stainless steel tubing (CSST). Please Note: items identified as Deficient (D) in an inspection report DO NOT obligate any party to make repairs or take other actions. The decision to correct a hazard or any deficiency identified in an inspection report is left up to the parties to the contract for the sale or purchase of the home. This property inspection report may include an inspection agreement (contract), addenda, and other information related to property conditions. INFORMATION INCLUDED UNDER "ADDITIONAL INFORMATION PROVIDED BY INSPECTOR", OR PROVIDED AS AN IS NOT REQUIRED BY THE COMMISSION AND MAY CONTAIN ATTACHMENT WITH THE STANDARD FORM, CONTRACTUAL TERMS BETWEEN THE INSPECTOR AND YOU, AS THE CLIENT. THE COMMISSION DOES NOT REGULATE CONTRACTUAL TERMS BETWEEN PARTIES. IF YOU DO NOT UNDERSTAND THE EFFECT OF ANY CONTRACTUAL TERM CONTAINED IN THIS SECTION OR ANY ATTACHMENTS, CONSULT AN ATTORNEY. ADDITIONAL INFORMATION PROVIDED BY INSPECTOR: In Attendance: Vacant (inspector only) Type of building: Single Family (1 story) Approximate age of building: Over 46 Years Temperature: Over 65 (F) = 18 (C) Rain in last 3 days: No Weather: Cloudy Radon Test: No Ground/Soil surface condition: Dry Water Test: No Year Built: 1957 Square Footage: 878 Rooms: Utilities On: None People Present at Inspection: Inspector REI 7-5 (05/04/2015) Page 3 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D I. Structural Systems The Home Inspector shall observe structural components including foundations, floors, walls, columns or piers, ceilings and roof. The home inspector shall describe the type of Foundation, floor structure, wall structure, columns or piers, ceiling structure, roof structure. The home inspector shall: Probe structural components where deterioration is suspected; Enter under floor crawl spaces, basements, and attic spaces except when access is obstructed, when entry could damage the property, or when dangerous or adverse situations are suspected; Report the methods used to observe under floor crawl spaces and attics; and Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components. The home inspector is not required to: Enter any area or perform any procedure that may damage the property or its components or be dangerous to or adversely effect the health of the home inspector or other persons. A. Foundations Foundation Type: Skirting Foundation Performance: Differential movement / settlement observed; indicated by one or more of the following observed conditions; Cracks in brick veneer and/or foundation, Cracks in sheetrock over doors and windows, doors that are not square in jamb, etc. In my opinion the distress patterns observed at the time of inspection are/were severe enough to recommend repair. The inspector recommends a qualified contractor examine further to advise and repair as necessary. Roof Covering Materials: Asphalt/Fiberglass Roof Vantage Point: Walked Roof, Ladder Evidence Of Roof Water Penetration: Yes Visable Roof Repairs: No Visable Repairs Method used to observe Crawlspace: Crawled, Limited access Columns or Piers: Wood piers Comments: (1) Damaged foundation skirting was observed. Recommend repair or replacement to prevent vermin and moisture intrusion and maintain structural integrity. A. Item 1 (Picture) Damaged foundation skirting was observed. Recommend repair or replacement to prevent vermin and moisture intrusion and maintain structural integrity. A. Item 2 (Picture) Damaged foundation skirting was observed. Recommend repair or replacement to prevent vermin and moisture intrusion and maintain structural integrity. (2) Sections of detached plumbing were observed under the crawl space. Recommend further evaluation by a qualified plumbing contractor to assess condition and determine necessary repairs. REI 7-5 (05/04/2015) Page 4 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D A. Item 3 (Picture) Sections of detached plumbing were observed under the crawl space. Recommend further evaluation by a qualified plumbing contractor to assess condition and determine necessary repairs. (3) Differential movement / settlement observed; indicated by one or more of the following observed conditions; Cracks in brick veneer and/or foundation, Cracks in sheetrock over doors and windows, doors that are not square in jamb, etc. In my opinion the distress patterns observed at the time of inspection are/ were severe enough to recommend repair. The inspector recommends a qualified contractor examine further to advise and repair as necessary. B. Grading and Drainage Comments: (1) Cracks and separation were observed at various locations of the driveway. Recommend monitoring and repair as necessary to prevent further deterioration and prevent tripping hazards. B. Item 1 (Picture) Cracks and separation were observed at various locations of the driveway. Recommend monitoring and repair as necessary to prevent further deterioration and prevent tripping hazards. B. Item 2 (Picture) Cracks and separation were observed at various locations of the driveway. Recommend monitoring and repair as necessary to prevent further deterioration and prevent tripping hazards. (2) Leaf litter and debris were observed at the carport and driveway, obstructing visibility and potentially concealing defects such as cracks or concrete separation. Recommend clearing the area and conducting further examination. REI 7-5 (05/04/2015) Page 5 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D B. Item 3 (Picture) Leaf litter and debris were observed at the carport and driveway, obstructing visibility and potentially concealing defects such as cracks or concrete separation. Recommend clearing the area and conducting further examination. (3) The neighboring wall was observed leaning significantly. Recommend repair or removal to maintain stability and prevent potential collapse or damage. B. Item 4 (Picture) The neighboring wall was observed leaning significantly. Recommend repair or removal to maintain stability and prevent potential collapse or damage. B. Item 5 (Picture) The neighboring wall was observed leaning significantly. Recommend repair or removal to maintain stability and prevent potential collapse or damage. (4) Sheds were observed on the property but were not inspected, as evaluation of detached structures is beyond the scope of a standard home inspection. B. Item 6 (Picture) Sheds were observed on the property but were not inspected, as evaluation of detached structures is beyond the scope of a standard home inspection. B. Item 7 (Picture) Sheds were observed on the property but were not inspected, as evaluation of detached structures is beyond the scope of a standard home inspection. REI 7-5 (05/04/2015) Page 6 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D (5) Loose and leaning fencing materials observed and recommend further examination by a qualified fencing contractor to advise and repair as necessary. B. Item 8 (Picture) Loose and leaning fencing materials observed and recommend further examination by a qualified fencing contractor to advise and repair as necessary. (6) Abandoned car on property. FYI B. Item 9 (Picture) Abandoned car on property. FYI C. Roof Covering Materials Viewed roof covering from: Ground, Ladder, Walked roof Comments: (1) Roof covering materials REI 7-5 (05/04/2015) Page 7 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D C. Item 1 (Picture) Roof covering materials C. Item 2 (Picture) Roof covering materials C. Item 3 (Picture) Roof covering materials C. Item 4 (Picture) Roof covering materials C. Item 5 (Picture) Roof covering materials C. Item 6 (Picture) Roof covering materials C. Item 7 (Picture) Roof covering materials (2) Vegetation was observed growing on the roof, and tree branches were overhanging the roof. Recommend removal to prevent damage and maintain roof integrity. REI 7-5 (05/04/2015) Page 8 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D C. Item 8 (Picture) Vegetation was observed growing on the roof, and tree branches were overhanging the roof. Recommend removal to prevent damage and maintain roof integrity. C. Item 9 (Picture) Vegetation was observed growing on the roof, and tree branches were overhanging the roof. Recommend removal to prevent damage and maintain roof integrity. C. Item 10 (Picture) Vegetation was observed growing on the roof, and tree branches were overhanging the roof. Recommend removal to prevent damage and maintain roof integrity. (3) A gravel roof was observed on a pitched roof, which is generally not recommended. Gravel systems are designed for flat or low-slope roofs to protect the membrane and provide ballast, but on pitched roofs they add unnecessary weight, make leaks difficult to locate, complicate maintenance, and increase risk of premature failure. Asphalt shingles, metal roofing, or other pitched roof materials are more appropriate. REI 7-5 (05/04/2015) Page 9 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D C. Item 11 (Picture) A gravel roof was observed on a pitched roof, which is generally not recommended. Gravel systems are designed for flat or low-slope roofs to protect the membrane and provide ballast, but on pitched roofs they add unnecessary weight, make leaks difficult to locate, complicate maintenance, and increase risk of premature failure. Asphalt shingles, metal roofing, or other pitched roof materials are more appropriate. (4) Gaps at roof vents observed and recommend repair to prevent potential moisture intrusions and or damage. C. Item 12 (Picture) Gaps at roof vents observed and recommend repair to prevent potential moisture intrusions and or damage. D. Roof Structures and Attics Roof-Type: Gable Method used to observe attic: From entry, Inaccessible Attic Inforrmation: Scuttle hole, 6 Inches or less Roof Structure: 2 X 8 Rafters Comments: (1) A cast iron vent was observed in the attic. Recommend further evaluation by a qualified contractor to assess condition and ensure proper function. REI 7-5 (05/04/2015) Page 10 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D D. Item 1 (Picture) A cast iron vent was observed in the attic. Recommend further evaluation by a qualified contractor to assess condition and ensure proper function. (2) Insulation in the attic was observed to be thin, and some batts may be covering older insulation that could contain asbestos. Identification and testing of asbestos-containing materials is beyond the scope of a standard home inspection. Recommend a qualified environmental contractor evaluate and test the insulation and perform remediation if necessary. D. Item 2 (Picture) Attic insulation is thin; older insulation underneath may contain asbestos. Recommend environmental evaluation and testing. (3) Vermin or pest nests were observed in the attic. Recommend removal and treatment, as well as identifying and correcting all potential access points to prevent infestations. D. Item 3 (Picture) Pest nests observed in attic; recommend removal, treatment, and sealing access points. (4) Moisture stains were observed in the attic and were dry at the time of inspection. Due to the lack of rain, it was not possible to determine if roof leaks are active. Recommend further evaluation and correction by a qualified contractor to prevent moisture damage. REI 7-5 (05/04/2015) Page 11 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D D. Item 4 (Picture) Moisture stains were observed in the attic and were dry at the time of inspection. Due to the lack of rain, it was not possible to determine if roof leaks are active. Recommend further evaluation and correction by a qualified contractor to prevent moisture damage. (5) A lack of collar ties was observed at the rafters. Recommend evaluation by a qualified roofing contractor to determine if installation or reinforcement is necessary for structural stability. D. Item 5 (Picture) A lack of collar ties was observed at the rafters. Recommend evaluation by a qualified roofing contractor to determine if installation or reinforcement is necessary for structural stability. (6) One or more areas of the attic is contains thin or missing insulation. I recommend a qualified contractor add insulation to correct the deficiency. REI 7-5 (05/04/2015) Page 12 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D D. Item 6 (Picture) One or more areas of the attic is contains thin or missing insulation. I recommend a qualified contractor add insulation to correct the deficiency. (7) Damaged attic scuttle hole door observed D. Item 7 (Picture) Damaged attic scuttle hole door observed D. Item 8 (Picture) (8) Damaged carport roof ceiling observed and recommend repair. D. Item 9 (Picture) Damaged carport roof ceiling observed and recommend repair. (9) Attic ambering is the oozing of sap from wooden rafters in an attic, caused by excessive heat that makes the wood "sweat". While it can be a natural process, it is often a warning sign of inadequate attic ventilation and insulation, which can lead to problems like mold and wood degradation over time. To fix it, you should improve your attic's insulation and ventilation to lower temperatures and moisture levels. Causes High heat: Excessive heat, often from poor insulation, causes the sap in the wood to become more liquid. Inadequate ventilation: A lack of proper airflow traps heat and moisture, intensifying the problem. Moisture and condensation: In winter, warm, moist air from inside the house can rise and condense on the cold attic surfaces, creating an environment that promotes mold and wood rot. REI 7-5 (05/04/2015) Page 13 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D D. Item 10 (Picture) Attic ambering is sap oozing from rafters due to excessive heat, often caused by poor insulation or inadequate ventilation. It can indicate potential moisture issues, mold, or wood degradation. Improving attic insulation and ventilation can help prevent further problems. E. Walls (Interior and Exterior) Wall Structure: 2 X 6 Wood Siding Style: Lap Siding Material: Composite board Wall Material: Gypsum Board Cabinetry: Wood Countertop: Laminate Comments: (1) The exterior siding paint was not tested for lead or asbestos at the time of inspection. Testing for hazardous materials is beyond the scope of a standard home inspection. Considering the potential age of the paint and the associated health risks, it is recommended that a qualified environmental company perform proper testing to determine the presence of lead, asbestos, or other hazardous materials and provide guidance for remediation if necessary. REI 7-5 (05/04/2015) Page 14 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D E. Item 1 (Picture) Exterior siding paint not tested for lead or asbestos; recommend environmental testing. E. Item 2 (Picture) Exterior siding paint not tested for lead or asbestos; recommend environmental testing. (2) Vegetation was observed growing on siding at various locations. Recommend removal to prevent moisture damage and further deterioration. E. Item 3 (Picture) Vegetation was observed growing on siding at various locations. Recommend removal to prevent moisture damage and further deterioration. (3) Siding wear and deterioration were observed throughout the exterior. Recommend further evaluation by a qualified contractor to determine necessary repairs or replacement. E. Item 4 (Picture) Siding wear and deterioration were observed throughout the exterior. Recommend further evaluation by a qualified contractor to determine necessary repairs or replacement. E. Item 5 (Picture) Siding wear and deterioration were observed throughout the exterior. Recommend further evaluation by a qualified contractor to determine necessary repairs or replacement. (4) Corner cracks were observed at walls and over door frames. Recommend monitoring and further evaluation by a qualified contractor to determine cause and repair as necessary. REI 7-5 (05/04/2015) Page 15 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D E. Item 6 (Picture) Corner cracks were observed at walls and over door frames. Recommend monitoring and further evaluation by a qualified contractor to determine cause and repair as necessary. E. Item 7 (Picture) Corner cracks were observed at walls and over door frames. Recommend monitoring and further evaluation by a qualified contractor to determine cause and repair as necessary. E. Item 8 (Picture) Corner cracks were observed at walls and over door frames. Recommend monitoring and further evaluation by a qualified contractor to determine cause and repair as necessary. E. Item 9 (Picture) Corner cracks were observed at walls and over door frames. Recommend monitoring and further evaluation by a qualified contractor to determine cause and repair as necessary. REI 7-5 (05/04/2015) Page 16 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D E. Item 10 (Picture) Corner cracks were observed at walls and over door frames. Recommend monitoring and further evaluation by a qualified contractor to determine cause and repair as necessary. E. Item 11 (Picture) Corner cracks were observed at walls and over door frames. Recommend monitoring and further evaluation by a qualified contractor to determine cause and repair as necessary. (5) A hole in the bathroom cabinet trim was observed, indicating damage. Repair or replacement is necessary for safety and insect entry prevention E. Item 12 (Picture) A hole in the bathroom cabinet trim was observed, indicating damage. Repair or replacement is necessary for safety and insect entry prevention E. Item 13 (Picture) A hole in the bathroom cabinet trim was observed, indicating damage. Repair or replacement is necessary for safety and insect entry prevention (6) Deteriorated sheathing was observed throughout the exterior. Recommend a full assessment by a qualified contractor to evaluate damage and wear, with repair or replacement as necessary to prevent further deterioration. REI 7-5 (05/04/2015) Page 17 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D E. Item 14 (Picture) Deteriorated sheathing was observed throughout the exterior. Recommend a full assessment by a qualified contractor to evaluate damage and wear, with repair or replacement as necessary to prevent further deterioration. F. Ceilings and Floors Ceiling Structure: 2X6, 6'" or better, Not visible Floor Structure: Wood joists Ceiling Materials: Gypsum Board Floor Covering(s): Comments: (1) Cracks were observed at various locations on the ceilings. These may be due to structural movement over time. Recommend monitoring and further evaluation by a qualified contractor to assess the cause and correct as necessary. (Tongue and Groove) F. Item 1 (Picture) Cracks were observed at various locations on the ceilings. These may be due to structural movement over time. Recommend monitoring and further evaluation by a qualified contractor to assess the cause and correct as necessary. F. Item 2 (Picture) Cracks were observed at various locations on the ceilings. These may be due to structural movement over time. Recommend monitoring and further evaluation by a qualified contractor to assess the cause and correct as necessary. (2) Possible insect frass was observed near baseboards at various interior locations. Recommend a qualified pest control contractor inspect to identify the point of access, check for potential wood-destroying insects, and correct or treat as necessary. REI 7-5 (05/04/2015) Page 18 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D F. Item 3 (Picture) Possible insect frass near baseboards; recommend pest control inspect for access points and wood- destroying insects. (3) Paint was not tested for lead or asbestos. Considering the home was built in the 1950s, and at the time of the inspection, testing for hazardous materials goes beyond the scope of a standard home inspection, recommend evaluation by a qualified environmental company to identify and remediate any potential hazards. F. Item 4 (Picture) Paint not tested for lead or asbestos; recommend environmental company evaluation due to 1950s construction. G. Doors (Interior and Exterior) Exterior Entry Doors: Wood Interior Doors: Hollow core Comments: (1) Deteriorated siding and trim were observed at various locations. Recommend further evaluation to determine replacement, some of these areas are likely past their service life. G. Item 1 (Picture) Deteriorated siding and trim were observed at various locations. Recommend further evaluation to determine replacement, some of these areas are likely past their service life. REI 7-5 (05/04/2015) Page 19 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D (2) The carport door near the kitchen was unable to be opened. Recommend repair to restore proper function. G. Item 2 (Picture) The carport door near the kitchen was unable to be opened. Recommend repair to restore proper function. (3) Non functioning/damaged screen door observed. G. Item 3 (Picture) Non functioning/damaged screen door observed. (4) The rear entry door was boarded, and the door frame and latch were damaged. Recommend repair or replacement to ensure proper security and functionality. H. Windows Window Types: Double-hung, Single-hung Window Manufacturer: UNKNOWN Comments: REI 7-5 (05/04/2015) Page 20 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D (1) Large gaps were observed under the front windows at siding corners. Recommend repair to help prevent potential moisture intrusion and insect entry. H. Item 1 (Picture) Large gaps were observed under the front windows at siding corners. Recommend repair to help prevent potential moisture intrusion and insect entry. (2) Cracked/broken glass observed in window and recommend repair to prevent injury from broken glass. H. Item 2 (Picture) Cracked/ broken glass observed in window and recommend repair to prevent injury from broken glass. (3) Visual defects observed between panels of glass at one more windows and recommend further examination by a qualified window contractor to identify and repair or replace as necessary. On IGUs that are filled with inert gas, and a window seal has failed, it's enhanced insulating factor of around two points may be gone. The visual defects between panels may worsen over time and windows cannot be cleaned without dismantling windows. REI 7-5 (05/04/2015) Page 21 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D H. Item 3 (Picture) Visual defects observed between panels of glass at one more windows and recommend further examination by a qualified window contractor to identify and repair or replace as necessary. On IGUs that are filled with inert gas, and a window seal has failed, it's enhanced insulating factor of around two points may be gone. The visual defects between panels may worsen over time and windows cannot be cleaned without dismantling windows. H. Item 4 (Picture) Visual defects observed between panels of glass at one more windows and recommend further examination by a qualified window contractor to identify and repair or replace as necessary. On IGUs that are filled with inert gas, and a window seal has failed, it's enhanced insulating factor of around two points may be gone. The visual defects between panels may worsen over time and windows cannot be cleaned without dismantling windows. L. Other Comments: (1) Trash and personal belongings from former occupants were piled throughout the home, obstructing visibility of the floor and walls. The door was left open prior to inspection, increasing the possibility of hazardous materials or pests within the debris. Recommend clearing all trash with caution and conducting further examination once the area is fully accessible and safe. L. Item 1 (Picture) Trash and personal belongings from former occupants were piled throughout the home, obstructing visibility of the floor and walls. The door was left open prior to inspection, increasing the possibility of hazardous materials or pests within the debris. Recommend clearing all trash with caution and conducting further examination once the area is fully accessible. L. Item 2 (Picture) Trash and personal belongings from former occupants were piled throughout the home, obstructing visibility of the floor and walls. The door was left open prior to inspection, increasing the possibility of hazardous materials or pests within the debris. Recommend clearing all trash with caution and conducting further examination once the area is fully accessible. REI 7-5 (05/04/2015) Page 22 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D (2) Vermin droppings were observed throughout the interior of the home. Recommend further evaluation and treatment by a qualified pest control contractor. L. Item 3 (Picture) Vermin droppings were observed throughout the interior of the home. Recommend further evaluation and treatment by a qualified pest control contractor. (3) Damaged and worn cabinetry was observed at various locations throughout the home. Recommend further evaluation and repair or replacement as necessary. L. Item 4 (Picture) Damaged and worn cabinetry was observed at various locations throughout the home. Recommend further evaluation and repair or replacement as necessary. The roof of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Roof coverings and skylights can appear to be leak proof during inspection and weather conditions. Our inspection makes an attempt to find a leak but sometimes cannot. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report. The Home Inspector shall observe structural components including foundations, floors, walls, columns or piers, ceilings and roof. The home inspector shall describe the type of Foundation, floor structure, wall structure, columns or piers, ceiling structure, roof structure. The home inspector shall: Probe structural components where deterioration is suspected; Enter under floor crawl spaces, basements, and attic spaces except when access is obstructed, when entry could damage the property, or when dangerous or adverse situations are suspected; Report the methods used to observe under floor crawl spaces and attics; and Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components. The home inspector is not required to: Enter any area or perform any procedure that may damage the property or its components or be dangerous to or adversely effect the health of the home inspector or other persons. REI 7-5 (05/04/2015) Page 23 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D II. Electrical Systems The home inspector shall observe: Service entrance conductors; Service equipment, grounding equipment, main over current device, and main and distribution panels; Amperage and voltage ratings of the service; Branch circuit conductors, their over current devices, and the compatibility of their ampacities and voltages; The operation of a representative number of installed ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls; The polarity and grounding of all receptacles within six feet of interior plumbing fixtures, and all receptacles in the garage or carport, and on the exterior of inspected structures; The operation of ground fault circuit interrupters; and Smoke detectors. The home inspector shall describe: Service amperage and voltage; Service entry conductor materials; Service type as being overhead or underground; and Location of main and distribution panels. The home inspector shall report any observed aluminum branch circuit wiring. The home inspector shall report on presence or absence of smoke detectors, and operate their test function, if accessible, except when detectors are part of a central system. The home inspector is not required to: Insert any tool, probe, or testing device inside the panels; Test or operate any over current device except ground fault circuit interrupters; Dismantle any electrical device or control other than to remove the covers of the main and auxiliary distribution panels; or Observe: Low voltage systems; Security system devices, heat detectors, or carbon monoxide detectors; Telephone, security, cable TV, intercoms, or other ancillary wiring that is not a part of the primary electrical distribution system; or Built-in vacuum equipment. A. Service Entrance and Panels Electrical Service Conductors: Overhead service, Copper, Aluminum Strand Panel Capacity: 150 AMP Panel Type: Circuit breakers, AFCI Breakers Electric Panel Manufacturer: GENERAL ELECTRIC Absence Of Smoke Alarms: Outside each separate sleeping area in immediate vicinity of the sleeping rooms Comments: (1) No electricity was on at the time of inspection; therefore, the electrical system, outlets, lighting, appliances, and any electrically operated equipment could not be tested or verified for proper operation. Recommend verification and testing by a qualified electrician once power is restored. A. Item 1 (Picture) Main panel cover removed (2) I observed (No) installed AFCI (Arc Fault Circuit Interrupt) device protection, as required by current REI 7-5 (05/04/2015) Page 24 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D building standards, for all: family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, recreations rooms, closets, hallways, or similar rooms or areas. AFCI devices are intended to protect against fires caused by electrical arcing faults in the home;s wiring. Arc faults are a common cause of residential electrical fires. Arc faults can be created by damaged, deteriorated, or worn electrical plugs, cords, and/or branch circuit conductors. As of September 1, 2008, the State of Texas has adopted the 2005 NEC, which includes this requirement, as the "minimum standard" for all non-exempt electrical work. Homes built prior to 2002, generally were not required to have arc fault protection. However, the current TREC standard of practice requires inspectors to indicate that a hazardous or deficient condition exists if any home does not have this protection, regardless of date the home was constructed. The electrical systems, service entrance and panels were performing as intended at the time of inspection and any deficiencies observed will be noted in this section of the report. A. Item 2 (Picture) Main panel cover removed (3) Tree branches were in contact with the service drop. Recommend trimming or contacting the utility company to clear vegetation and maintain safe clearance. REI 7-5 (05/04/2015) Page 25 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D A. Item 4 (Picture) Service mast A. Item 3 (Picture) Tree branches were in contact with the service drop. Recommend trimming or contacting the utility company to clear vegetation and maintain safe clearance. B. Branch Circuits, Connected Devices and Fixtures Branch wire 15 and 20 AMP: Copper, Aluminum Type Of Wiring: Romex, Conduit Comments: (1) No electricity was on at the time of inspection; therefore, the electrical system, outlets, lighting, appliances, and any electrically operated equipment could not be tested or verified for proper operation. Recommend verification and testing by a qualified electrician once power is restored. (2) Some outlets were observed to be two-prong and not grounded. Ungrounded outlets do not provide adequate protection for modern electrical devices and can pose a safety concern. Recommend evaluation and upgrade to grounded outlets by a qualified electrician. B. Item 1 (Picture) Two-prong ungrounded outlets observed; recommend electrician upgrade. (3) Older Romex-type branch wiring with inadequate or missing grounding was observed, and three-prong outlets were installed without “no equipment ground” labels. These conditions present electrical shock and fire hazards, do not comply with current NEC safety standards, and should be evaluated and corrected by a qualified electrician. REI 7-5 (05/04/2015) Page 26 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D B. Item 2 (Picture) Older ungrounded wiring and unlabeled three-prong outlets observed; recommend electrician evaluation and correction. B. Item 3 (Picture) Older ungrounded wiring and unlabeled three-prong outlets observed; recommend electrician evaluation and correction. The smoke detector should be tested at common hallway to bedrooms upon moving in to home. The electrical system of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Outlets were not removed and the inspection was only visual. Any outlet not accessible (behind the refrigerator for example) was not inspected or accessible. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report. The smoke detectors should be tested upon moving in to home. There is no carbon monoxide detector found in home. It is recommended that one be installed according to the manufacturer's instructions. REI 7-5 (05/04/2015) Page 27 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D III. Heating, Ventilation and Air Conditioning Systems The home inspector shall observe permanently installed heating and cooling systems including: Heating equipment; Cooling Equipment that is central to home; Normal operating controls; Automatic safety controls; Chimneys, flues, and vents, where readily visible; Solid fuel heating devices; Heat distribution systems including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units, convectors; and the presence of an installed heat source in each room. The home inspector shall describe: Energy source; and Heating equipment and distribution type. The home inspector shall operate the systems using normal operating controls. The home inspector shall open readily openable access panels provided by the manufacturer or installer for routine homeowner maintenance. The home inspector is not required to: Operate heating systems when weather conditions or other circumstances may cause equipment damage; Operate automatic safety controls; Ignite or extinguish solid fuel fires; or Observe: The interior of flues; Fireplace insert flue connections; Humidifiers; Electronic air filters; or The uniformity or adequacy of heat supply to the various rooms. A. Heating Equipment Heat Type: Electric heat, None Energy Source: Electric Number of Heat Systems (excluding wood): One Heat System Brand: UNKNOWN Comments: An aged in-wall heater was observed in the bathroom. Operation could not be verified due to lack of electricity at the time of inspection. Recommend further evaluation by a qualified HVAC or electrical contractor to determine condition and functionality. A. Item 1 (Picture) Aged bathroom wall heater not tested due to no power; recommend evaluation. B. Cooling Equipment Cooling Equipment Type: Air conditioner unit Cooling Equipment Energy Source: Electricity Number of AC Only Units: One Central Air Brand: UNKNOWN Comments: The HVAC unit appeared aged and was not tested due to lack of electricity at the time of inspection. Given its apparent age and unknown condition, recommend further evaluation by a qualified HVAC contractor for potential complete replacement. REI 7-5 (05/04/2015) Page 28 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D B. Item 1 (Picture) Aged HVAC unit not tested due to no power; recommend evaluation for possible replacement. B. Item 2 (Picture) No ducts observed to bedrooms; recommend HVAC contractor verify and correct as needed. C. Duct Systems, Chases and Vents Ductwork: N/A Filter Type: N/A Filter Size: N/A Comments: No rigid ductwork or supply ducts were observed entering any of the bedrooms at the time of inspection. Recommend further evaluation by a qualified HVAC contractor to locate any concealed ducts and perform additions or repairs as necessary to ensure proper air distribution and comfort. C. Item 1 (Picture) No ducts observed to bedrooms; recommend HVAC contractor verify and correct as needed. The heating and cooling system of this home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. The inspection is not meant to be technically exhaustive. The inspection does not involve removal and inspection behind service door or dismantling that would otherwise reveal something only a licensed heat contractor would discover. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report. The cooling system of this home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. The inspection is not meant to be technically exhaustive. The inspection does not involve removal and inspection behind service door or dismantling that would otherwise reveal something only a licensed HVAC contractor would discover (Heating, Ventilation, and Air Conditioning). Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report. The following Structural items or discoveries indicate that these systems or components do not function as intended or adversely affects the habitability of the dwelling; or warrants further investigation by a specialist, or requires subsequent observation. This summary shall not contain recommendations for routine upkeep of a system or component to keep it in proper functioning condition or recommendations to upgrade or enhance the function or efficiency of the building. This Summary is not the entire report. The complete report may include additional information of concern to the customer. It is recommended that the customer read the complete report. REI 7-5 (05/04/2015) Page 29 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D IV. Plumbing System The home inspector shall observe: Interior water supply and distribution system, including: piping materials, supports, and insulation; fixtures and faucets; functional flow; leaks; and cross connections; Interior drain, waste, and vent system, including: traps; drain, waste, and vent piping; piping supports and pipe insulation; leaks; and functional drainage; Hot water systems including: water heating equipment; normal operating controls; automatic safety controls; and chimneys, flues, and vents; Fuel storage and distribution systems including: interior fuel storage equipment, supply piping, venting, and supports; leaks; and Sump pumps. The home inspector shall describe: Water supply and distribution piping materials; Drain, waste, and vent piping materials; Water heating equipment; and Location of main water supply shutoff device. The home inspector shall operate all plumbing fixtures, including their faucets and all exterior faucets attached to the house, except where the flow end of the faucet is connected to an appliance. The home inspector is not required to: State the effectiveness of anti-siphon devices; Determine whether water supply and waste disposal systems are public or private; Operate automatic safety controls; Operate any valve except water closet flush valves, fixture faucets, and hose faucets; Observe: Water conditioning systems; Fire and lawn sprinkler systems; On-site water supply quantity and quality; On-site waste disposal systems; Foundation irrigation systems; Spas, except as to functional flow and functional drainage; Swimming pools; Solar water heating equipment; or Observe the system for proper sizing, design, or use of proper materials. A. Plumbing Supply, Distribution System and Fixtures Water Source: Public Water Filters: None Plumbing Water Supply (into home): PVC, CPVC Plumbing Water Distribution (inside home): PVC Water Heater Manufacturer: GE Location of water meter: Front By The Street Location of main water supply valve: Unknown Location and Recommend Asking Seller For Future Reference Comments: (1) Areas of drainage in the crawl space were observed to have cast iron drain lines, which were not tested for leaks at the time of inspection. Cast iron piping is known to deteriorate over time due to internal corrosion, scaling, and rust, which can lead to blockages, leaks, and structural weakening. Given the age and known issues associated with cast iron drains, recommend further examination by a qualified plumbing contractor to assess condition and consider replacement as necessary. REI 7-5 (05/04/2015) Page 30 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D A. Item 1 (Picture) Areas of drainage in the crawl space were observed to have cast iron drain lines, which were not tested for leaks at the time of inspection. Cast iron piping is known to deteriorate over time due to internal corrosion, scaling, and rust, which can lead to blockages, leaks, and structural weakening. Given the age and known issues associated with cast iron drains, recommend further examination by a qualified plumbing contractor to assess condition and consider replacement as necessary. (2) An old waste arm pipe was observed, appearing to be either Orangeburg or cast iron. Both materials are known to have significant aging and durability issues—Orangeburg pipe is made of bituminized fiber, which tends to deform, blister, and collapse over time, while cast iron is prone to internal corrosion, rust, and scaling that can restrict flow and cause leaks. Recommend further examination by a qualified plumbing contractor to verify material type, assess condition, and replace as necessary. A. Item 2 (Picture) Old Orangeburg or cast iron waste arm observed; both prone to failure—recommend plumber evaluation and replacement if needed. (3) Sections of plumbing under the crawl space obstructed access, and therefore those portions of the crawl space were not inspected. These areas are excluded from the scope of this inspection. Recommend further evaluation by a qualified contractor to confirm conditions in inaccessible areas. REI 7-5 (05/04/2015) Page 31 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D A. Item 3 (Picture) Sections of plumbing under the crawl space obstructed access, and therefore those portions of the crawl space were not inspected. These areas are excluded from the scope of this inspection. Recommend further evaluation by a qualified contractor to confirm conditions in inaccessible areas. B. Drains, Waste and Vents Washer Drain Size: 2" Diameter Plumbing Waste: Cast iron, AGED Comments: The toilet was not properly fastened, and its operation could not be verified. It may be leaking. Recommend repair or reinstallation by a qualified plumbing contractor to ensure stability and proper function. B. Item 1 (Picture) Toilet not fastened; operation not verifiable, may be leaking—recommend plumber repair. C. Water Heating Equipment Water Heater Power Source: Natural Gas Water Heater Capacity: 40 Gallon Water Heater Location: Utility Room, Washer Dryer Room Comments: (1) The water heater was manufactured in 2010, making it well past the typical service life of approximately 8–12 years. The unit was not tested at the time of inspection because no gas or water service was active. Additionally, no gas drip leg (sediment trap) was installed. Recommend further evaluation and replacement as necessary by a qualified plumbing contractor once utilities are activated. REI 7-5 (05/04/2015) Page 32 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D C. Item 2 (Picture) Water heater was manufactured in 2010 C. Item 1 (Picture) Water heater from 2010—past service life, not tested due to no gas/water, and missing drip leg; recommend plumber evaluation. (2) The gas water heater vent was observed detached, which is a safety hazard that can allow combustion gases to enter the home once utilities are active. Recommend evaluation and repair by a qualified HVAC or plumbing contractor to ensure proper venting and safe operation when the system is in use. C. Item 3 (Picture) Water heater vent detached; recommend repair by qualified contractor once utilities are active. (3) The water heater drip pan in the utility closet was damaged and contained debris. Additionally, the closet door does not fully close. Recommend cleaning, repairing or replacing the drip pan, and adjusting the door for proper access and safety. REI 7-5 (05/04/2015) Page 33 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D C. Item 4 (Picture) The water heater drip pan in the utility closet was damaged and contained debris. Additionally, the closet door does not fully close. Recommend cleaning, repairing or replacing the drip pan, and adjusting the door for proper access and safety. (4) Moisture stains were observed at the ceiling penetrations around the water heater vent. No rain was present at the time of inspection, so it was not possible to determine if there are active leaks. Recommend further evaluation by a qualified contractor to determine any active leaks or damage in attic above water heater. C. Item 5 (Picture) Moisture stains at water heater vent penetrations; no rain—recommend contractor evaluation. (5) Galvanized piping was observed at the water heater supply. Galvanized pipes are prone to corrosion and mineral buildup over time, which can reduce water flow and lead to leaks. Recommend evaluation by a qualified plumbing contractor to determine condition and consider replacement if necessary. REI 7-5 (05/04/2015) Page 34 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D C. Item 6 (Picture) Galvanized piping at water heater supply; recommend plumber evaluation. (6) The water heater exhaust vent was observed to be a single-wall type, which is not appropriate for gas venting. A proper Type B vent is required to safely exhaust combustion gases. Recommend replacement with a Type B vent by a qualified HVAC or plumbing contractor. C. Item 7 (Picture) Water heater vent is single-wall; recommend replacement with Type B vent. E. Gas Distribution Systems and Gas Appliances Comments: No gas meter was present at the time of inspection; therefore, all gas appliances were not tested or inspected for operation. Recommend further verification by the builder or a qualified contractor to confirm gas service installation and appliance functionality once connected. REI 7-5 (05/04/2015) Page 35 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D E. Item 1 (Picture) No gas meter was present at the time of inspection; therefore, all gas appliances were not tested or inspected for operation. Recommend further verification by the builder or a qualified contractor to confirm gas service installation and appliance functionality once connected. F. Other Comments: (1) Bathtub/shower fixtures were observed with damage and/or missing hardware. Recommend further evaluation, testing, and repair by a qualified plumbing contractor to ensure proper operation and function. F. Item 1 (Picture) Damaged or incomplete bathtub fixtures; recommend plumber evaluation and repair. (2) Rust and corrosion were observed at the plumbing drains. The area was not tested for leaks at the time of inspection. Recommend further evaluation and repair by a qualified plumbing contractor to ensure proper function and prevent potential leakage. REI 7-5 (05/04/2015) Page 36 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D F. Item 2 (Picture) Rust and corrosion were observed at the plumbing drains. The area was not tested for leaks at the time of inspection. Recommend further evaluation and repair by a qualified plumbing contractor to ensure proper function and prevent potential leakage. F. Item 3 (Picture) Rust and corrosion were observed at the plumbing drains. The area was not tested for leaks at the time of inspection. Recommend further evaluation and repair by a qualified plumbing contractor to ensure proper function and prevent potential leakage. (3) Separation was observed at the floor and tub corner. Recommend further evaluation by a qualified contractor to identify the cause and perform corrective repairs as necessary. F. Item 4 (Picture) Floor/tub corner separation; recommend contractor evaluation and repair. Home inspectors are not required to report on the following: Life expectancy of any component or system; The causes of the need for a repair; The methods, materials, and costs of corrections; The suitability of the property for any specialized use; Compliance or non-compliance with codes, ordinances, statutes, regulatory requirements or restrictions; The market value of the property or its marketability; The advisability or inadvisability of purchase of the property; Any component or system that was not observed; The presence or absence of pests such as wood damaging organisms, rodents, or insects; or Cosmetic items, underground items, or items not permanently installed. Home inspectors are not required to: Offer warranties or guarantees of any kind; Calculate the strength, adequacy, or efficiency of any system or component; Enter any area or perform any procedure that may damage the property or its components or be dangerous to the home inspector or other persons; Operate any system or component that is shut down or otherwise inoperable; Operate any system or component that does not respond to normal operating controls; Disturb insulation, move personal items, panels, furniture, equipment, plant life, soil, snow, ice, or debris that obstructs access or visibility; Determine the presence or absence of any suspected adverse environmental condition or hazardous substance, including but not limited to mold, toxins, carcinogens, noise, contaminants in the building or in soil, water, and air; Determine the effectiveness of any system installed to control or remove suspected hazardous substances; Predict future condition, including but not limited to failure of components; Since this report is provided for the specific benefit of the customer(s), secondary readers of this information should hire a licensed inspector to perform an inspection to meet their specific needs and to obtain current information concerning this property. REI 7-5 (05/04/2015) Page 37 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D V. Appliances The home inspector shall observe and operate the basic functions of the following kitchen appliances: Permanently installed dishwasher, through its normal cycle; Range, cook top, and permanently installed oven; Trash compactor; Garbage disposal; Ventilation equipment or range hood; and Permanently installed microwave oven. The home inspector is not required to observe: Clocks, timers, self-cleaning oven function, or thermostats for calibration or automatic operation; Non built-in appliances; or Refrigeration units. The home inspector is not required to operate: Appliances in use; or Any appliance that is shut down or otherwise inoperable. A. Dishwasher Comments: B. Food Waste Disposers Comments: Electricity was off at the time of inspection; therefore, appliances, outlets, and other electrical components could not be tested for performance. Recommend further evaluation by a qualified electrical contractor to verify proper operation and correct any deficiencies as necessary. C. Range Hood and Exhaust System Comments: Electricity was off at the time of inspection; therefore, appliances, outlets, and other electrical components could not be tested for performance. Recommend further evaluation by a qualified electrical contractor to verify proper operation and correct any deficiencies as necessary. D. Ranges, Cooktops and Ovens Comments: No gas meter was present at the time of inspection; therefore, all gas appliances were not tested or inspected for operation. Recommend further verification by the builder or a qualified contractor to confirm gas service installation and appliance functionality once connected. REI 7-5 (05/04/2015) Page 38 of 39 Report Identification: 2406 E Martin Luther King Jr Blvd I = Inspected NI = Not Inspected NP = Not Present D = Deficient I NI NP D D. Item 1 (Picture) No Anti tip device was present and is recommended. D. Item 2 (Picture) No gas meter present; gas appliances not tested—recommend verification. E. Microwave Ovens Comments: F. Mechanical Exhaust Vents and bathroom Heaters Comments: Electricity was off at the time of inspection; therefore, appliances, outlets, and other electrical components could not be tested for performance. Recommend further evaluation by a qualified electrical contractor to verify proper operation and correct any deficiencies as necessary. G. Garage Door Operator(s) Comments: I. Refrigerator Comments: The built-in appliances of the home were inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report. REI 7-5 (05/04/2015) Page 39 of 39