Historic Landmark CommissionAug. 6, 2025

16.1 - 705 Brownlee Cir - Drawings — original pdf

Backup
Thumbnail of the first page of the PDF
Page 1 of 32 pages

05/08/2025 BRWN NEW 4-UNIT RESIDENCE 705 Brownlee Circle Austin Texas 78703 U.S.A. CDPROC 49 May 14, 2025 e.g. CDPROC25April 03 2025SCOPE (NEW, RENOVATION, ADDITION)BRWN705 Brownlee Circle Austin Texas 78703 U.S.A. VICINITY MAP y p x c E a P o M 705 BROWNLEE CIRCLE, AUSTIN, TX 78703,EE.UU R O D L F WIN W Cesar Chavez St C OLO R A D O RIVE R LEGAL DESCRIPTION PROJECT ADDRESS: 705 Brownlee Circle Austin Texas 78703 U.S.A. LEGAL DESCRIPTION: LOT 32 OF PARK VIEW, VOLUME 5, PAGE 69, PLAT RECORDS, TRAVIS CO.,TX DESCRIPTION OF WORK: DEMOLITION OF EXISTING DUPLEX AND CONSTRUCTION OF NEW 4-UNIT RESIDENCE OWNER'S NAME: BRAD HOSKINS & MELISSA SKIDMORE E N FIE L D R D W 15th St D LV R B A M A N L PROJECT TEAM MEMBERS ARCHITECT WEBBER + STUDIO 1220 LAVACA ST AUSTIN, TX 78701 512-236-1032 STRUCTURAL ENGINEER FORT STRUCTURES 2120 E 7th ST. STE 200 Austin, TX 78702 MECHANICAL ENGINEER FRESH AIR SIZING 3306 DALTON ST AUSTIN, TX 78745 512-466-7679 ELECTRICAL & PLUMBING ENGINEER S3 INGENIEROS KPMG BUILDING L2 ESCAZU, COSTA RICA +506-4020-2342 GEOTECHNICAL ENGINEER HOLT ENGINEERING, INC. 2220 BARTON SKYWAY AUSTIN, TX 78704 512-447-8166 W Cesar Chavez St y w L H A N GIO E R R E T IN WATERPROOFIING CONSULTANT ACTON PARTNERS P.O. BOX 203663 AUSTIN, TX 78720-3663 CIVIL ENGINEER TBD LANDSCAPE ARCHITECT TBD INTERIOR DESIGNER TBD CONTRACTOR/BUILDER TBD SHEET INDEX ARCHITECTURAL PERMIT G001 G001 G002 G002 G003 G003 G004 G004 G005 G005 G006 G006 G100 G100 G101 G101 G102 G102 G103 G103 G104 G104 G105 G106 G106 G107 G107 D001 G201 D101 D001 D102 D101 SP101 D102 SP102 SP101 SP103 SP102 A100 SP103 A101 A100 A102 A101 A103 A102 A110 A103 A111 A110 A112 A111 A113 X111 A114 A112 A120 A113 A121 A114 A122 A120 A123 A121 A129 A122 A200 A123 A201 A129 A202 A130 A300 A131 A301 A132 A302 A133 A303 A134 A304 A200 A305 A201 A306 A202 A307 A300 A308 A301 A309 A302 A310 A303 A311 A304 A312 A305 A313 A306 A501 A307 A502 A308 A503 A309 A504 A310 A505 A311 A506 A401 A601 A402 A602 A403 A603 A404 A604 A405 A606 A406 A700 A407 A701 A408 SC100 A409 SC101 A410 SC102 A411 SC103 A412 SC104 A413 A414 A501 A502 A503 A504 A505 A506 A510 A520 COVER SHEET COVER SHEET PROJECT INFORMATION PROJECT INFORMATION PROPERTY INFORMATION PROPERTY INFORMATION EXISTING CONDITIONS PHOTOS EXISTING CONDITIONS PHOTOS ABBREVIATIONS, SYMBOLS, LEGENDS & GENERAL NOTES ABBREVIATIONS, SYMBOLS, LEGENDS & GENERAL NOTES KEYNOTES & SUBMITTAL REQS KEYNOTES & SUBMITTAL REQS PERMIT, CODE AND ZONING INFORMATION PERMIT, CODE AND ZONING INFORMATION IMPERVIOUS COVER DIAGRAM IMPERVIOUS COVER DIAGRAM BUILDING AREA DIAGRAM BUILDING AREA DIAGRAM BUILDING HEIGHT DIAGRAMS BUILDING HEIGHT DIAGRAMS FIRE SEPARATION DIAGRAMS FIRE SEPARATION DIAGRAMS ACCESSIBILITY STANDARDS & DETAILS ACCESSIBILITY INFORMATION - SITE ACCESSIBILITY INFORMATION - SITE ACCESSIBILITY INFORMATION - BUILDING ACCESSIBILITY INFORMATION - BUILDING DEMOLITION SITE PLAN OUTLINE SPECIFICATIONS DEMOLITION PLAN : 1st FLOOR DEMOLITION SITE PLAN DEMOLITION PLAN : ROOF DEMOLITION PLAN : 1st FLOOR LOT PLAN DEMOLITION PLAN : ROOF ARCHITECTURAL SITE PLAN LOT PLAN PLOT PLAN ARCHITECTURAL SITE PLAN FINISH AND MARKER PLAN : BASEMENT PLOT PLAN FINISH AND MARKER PLAN : 1st LEVEL FINISH AND MARKER PLAN : BASEMENT FINISH AND MARKER PLAN : 2nd LEVEL FINISH AND MARKER PLAN : 1st LEVEL FINISH AND MARKER PLAN : PH & ROOF DECK FINISH AND MARKER PLAN : 2nd LEVEL DIMENSION FLOOR PLAN : BASEMENT FINISH AND MARKER PLAN : PH & ROOF DECK DIMENSION FLOOR PLAN : 1st LEVEL DIMENSION FLOOR PLAN : BASEMENT DIMENSION FLOOR PLAN : 2nd LEVEL DIMENSION FLOOR PLAN : 1st LEVEL DIMENSION FLOOR PLAN : PH & ROOF DECK OP B FLOOR PLAN : 1st FLOOR DIMENSION FLOOR PLAN : ROOF DIMENSION FLOOR PLAN : 2nd LEVEL RCP : BASEMENT DIMENSION FLOOR PLAN : PH & ROOF DECK RCP : 1st FLOOR DIMENSION FLOOR PLAN : ROOF RCP : 2nd FLOOR RCP : BASEMENT RCP : PENTHOUSE RCP : 1st FLOOR MEP SITE PLAN RCP : 2nd FLOOR BUILDING ELEVATIONS N & S RCP : PENTHOUSE BUILDING ELEVATIONS E & W MEP SITE PLAN BUILDING ELEVATIONS OBSCURED MEP FLOOR PLAN: BASEMENT BUILDING SECTIONS MEP FLOOR PLAN : FIRST LEVEL BUILDING SECTION MEP FLOOR PLAN : SECOND FLOOR BUILDING SECTIONS MEP FLOOR PLAN: THIRD LEVEL BUILDING SECTIONS MEP TYPICAL NOTES, SYMBOLS BUILDING SECTIONS BUILDING ELEVATIONS N & S BUILDING SECTIONS BUILDING ELEVATIONS E & W BUILDING SECTIONS BUILDING ELEVATIONS OBSCURED BUILDING SECTIONS BUILDING SECTIONS BUILDING SECTIONS BUILDING SECTIONS BUILDING SECTIONS BUILDING SECTIONS BUILDING SECTIONS BUILDING SECTIONS BUILDING SECTIONS BUILDING SECTIONS BUILDING SECTIONS BUILDING SECTIONS BUILDING SECTIONS BUILDING SECTIONS TYPICAL ASSEMBLIES - WALLS BUILDING SECTIONS TYPICAL ASSEMBLIES - WALLS BUILDING SECTIONS TYPICAL ASSEMBLIES - PARTITIONS BUILDING SECTIONS TYPICAL ASSEMBLIES - FLOOR/ CEILINGS BUILDING SECTIONS TYPICAL ASSEMBLIES - FLOOR/ CEILINGS SITE SECTIONS TYPICAL ASSEMBLIES - ROOFS INTERIOR ELEVATIONS 1ST FLOOR : LOBBY & GARAGE PRIMARY STAIR & DETAILS INTERIOR ELEVATIONS 2ND FLOOR: LIVING & KITCHEN PRIMARY STAIR INTERIOR ELEVATIONS 2ND FLOOR : LIVING ROOM SPIRAL STAIR INTERIOR ELEVATIONS 2ND FLOOR : KITCHEN ELEVATOR PLAN & DETAILS INTERIOR ELEVATIONS 2ND FLOOR: OFFICE STAIR & RAILING DETAILS INTERIOR ELEVATIONS 2ND FLOOR : PETER'S ROOM DOOR SCHEDULES, TYPES & HARDWARE SCHEDULE INTERIOR ELEVATIONS 2ND FLOOR : M BEDROOM WINDOW SCHEDULE & TYPES INTERIOR ELEVATIONS 2ND FLOOR : M CLOSET & M BATH STRUCT COORD PLAN - BASEMENT INTERIOR ELEVATIONS : ROOF DECK : ROOF DECK STRUCT. COORD PLAN - 1ST LEVEL INTERIOR ELEVATION : ROOF DECK : PENTHOUSE STRUCT. COORD PLAN - 2ND LEVEL INTERIOR ELEVATION : BASEMENT : SECRET ROOM & KITCHENETTE STRUCT COORD PLAN - PH / ROOF DECK INTERIOR ELEVATION : BASEMENT : BATH STRUCT COORD PLAN - PH ROOF INTERIOR ELEVATION : 1ST FLOOR : LIVING, KITCHEN, & BEDROOM INTERIOR ELEVATION : 1ST FLOOR : KITCHEN & LIVING TYPICAL ASSEMBLIES - WALLS TYPICAL ASSEMBLIES - WALLS TYPICAL ASSEMBLIES - PARTITIONS TYPICAL ASSEMBLIES - FLOOR/ CEILINGS TYPICAL ASSEMBLIES - FLOOR/ CEILINGS TYPICAL ASSEMBLIES - ROOFS TYPICAL EXTERIOR PLAN DETAILS FOUNDATION SECTION DETAILS NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION 05/08/2025 3 0 7 8 7 ● s a x e T , n i t s u A ● e c r i l l C e e n w o r B 5 0 7 N W R B I E C N E D S E R T N U - 4 W E N I 1220 Lavaca Street Austin, TX, 78701 WebberStudio.com CURRENT ISSUE CDPROC50 14 May 2025 REVISIONS MARK DATE ISSUE 05.13.25 CDPROC49 PERMIT G002 PROJECT INFORMATION 2 OF 117 COPYRIGHT © 2025 WEBBER+STUDIO ARCHITECTS M P 5 3 : 1 | 5 2 0 2 , 4 1 y a M , y a d s e n d e W | # # # # . r e V | 3 0 3 0 5 2 _ N W R B / T O D U T S / 7 2 d a c h c r A I i r o f i c s a B d u o c M B - I l l a c o l . 7 2 d u o c M B I l : l d u o c M B I LOOKING SOUTH; TREES 878, 874, (877 REMOVED) & 876 LOOKING SOUTHWEST; TREE 877 REMOVED, 874 M P 5 3 : 1 | 5 2 0 2 , 4 1 y a M , y a d s e n d e W | # # # # . r e V | 3 0 3 0 5 2 _ N W R B / T O D U T S / 7 2 d a c h c r A I i r o f i c s a B d u o c M B - I l l a c o l . 7 2 d u o c M B I l : l d u o c M B I TREE PROTECTION NOTES 12 GA. WIRE (OR STRAPS) STAPLED TO 2X6s. THIS METHOD PROTECTS TRUNK FROM DAMAGE BY CONSTRUCTION EQUIPMENT. IT DOES NOT PROTECT ROOTS FROM COMPACTION. NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION 05/08/2025 TREE TRUNK PROTECTION BARRIER SHOULD EXTEND THE FULL DIAMETER OF THE TREE CROWN GALV. CHAIN LINK FENCE MATERIAL SUPPORTED BY GALV. MTL FENCE POSTS OR EQUIVALENT CONSTRUCTION FENCE. THIS METHOD PROTECTS TREE FROM ROOT COMPACTION FROM CONSTRUCTION EQUIPMENT. " 0 - ' 6 D E D N E M M O C E R TREE PROTECTION BARRIER IT IS THE ARCHITECT'S AND OWNER'S INTENT TO PROTECT ALL TREES IN PROXIMITY TO CONSTRUCTION AREA FROM DAMAGE OR INJURY DUE TO CONSTRUCTION. THE SUGGESTIONS FOR TREE PROTECTION PROVIDED ABOVE ARE EXPLICITLY NOT GUARANTEED TO FULLY PROTECT THE TREES. IT IS HIGHLY RECOMMENDED THAT A TREE SPECIALIST BE HIRED AND THAT SUCH COST BE REVIEWED WITH OWNER FOR IF APPROVAL PRIOR TO PROCUREMENT OF TREE SPECIALIST SERVICES. CONTRACTOR DOES NOT REVIEW WITH OWNER HIS OR HER WILLINGNESS OR NON- WILLINGNESS TO HIRE SUCH SPECIALIST, THEN IT WILL BE CONSTRUED AS CONTRACTOR'S WILLINGNESS TO ACCEPT LIABILITY FOR PROTECTING THE TREES FROM ANY DAMAGE THROUGHOUT THE CONSTRUCTION PROCESS. N W R B 3 0 7 8 7 ● s a x e T , n i t s u A ● e c r i l l C e e n w o r B 5 0 7 I E C N E D S E R T N U - 4 W E N I EXAMPLE: 20 IN. DIAMETER TREE 1/4 CRZ 5'-0" 1/2 CRZ 10'-0" FULL CRZ 20'-0" 1/4 CRZ - NO IMPACT 1/2 CRZ - NO CUT/FILL > 4" FULL CRZ - PRESERVE 50% CITY CODE REQUIRES THAT PROPOSED DEVELOPMENTS DEMONSTRATE THAT TREES ARE PRESERVED TO THE MAXIMUM EXTENT REASONABLE AND FEASIBLE. TREE PRESERVATION IS EFFECTIVELY DEFINED AS ROOT SYSTEM PRESERVATION; A CRITICAL ROOT ZONE AREA (CRZ) IS ASSIGNED TO EACH TREE, BASED ON TRUNK DIAMETER SIZE. A MINIMUM OF 50% OF THE CRZ IS REQUIRED TO BE LEFT UNDISTURBED TO ACHIEVE MINIMAL CONFORMANCE WITH THE REGULATIONS. 1220 Lavaca Street Austin, TX, 78701 WebberStudio.com UPDATED TREE TABLE NOTES: 1. SURVEY IS LESS THAN 3 YEARS OLD 2. TREE 877 (21" HACKBERRY) WAS DAMAGED IN A STORM AND REMOVED CURRENT ISSUE CDPROC50 14 May 2025 REVISIONS MARK DATE ISSUE 05.13.25 CDPROC49 PERMIT G003 PROPERTY INFORMATION 3 OF 117 COPYRIGHT © 2025 WEBBER+STUDIO ARCHITECTS NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION 05/08/2025 EXISTING DUPLEX - EAST (SIDE) ELEVATION - SOUTH CORNER EXISTING DUPLEX - EAST (SIDE) ELEVATION - NORTH CORNER EXISTING DUPLEX - NORTH (FRONT) ELEVATION N W R B I E C N E D S E R T N U - 4 W E N I 3 0 7 8 7 ● s a x e T , n i t s u A ● e c r i l l C e e n w o r B 5 0 7 M P 5 3 : 1 | 5 2 0 2 , 4 1 y a M , y a d s e n d e W | # # # # . r e V | EXISTING DUPLEX - WEST (SIDE) ELEVATION EXISTING DUPLEX - SOUTH (BACK) ELEVATION - WEST CORNER EXISTING DUPLEX - SOUTH (BACK) ELEVATION - EAST CORNER 3 0 3 0 5 2 _ N W R B / T O D U T S / 7 2 d a c h c r A I i r o f i c s a B d u o c M B - I l l a c o l . 7 2 d u o c M B I l : l d u o c M B I EXISTING CARPORT - WEST (SIDE) ELEVATION EXISTING CARPORT - SOUTH (BACK) ELEVATION EXISTING CARPORT - EAST (SIDE) ELEVATION 1220 Lavaca Street Austin, TX, 78701 WebberStudio.com CURRENT ISSUE CDPROC50 14 May 2025 REVISIONS MARK DATE ISSUE 05.13.25 CDPROC49 PERMIT G004 EXISTING CONDITIONS PHOTOS 4 OF 117 COPYRIGHT © 2025 WEBBER+STUDIO ARCHITECTS HVAC & POOL EQUIPMENT UNDER PARKING DECK Other covered or roofed area 219.00 1st Floor Conditioned Area 321.16 Unconditioned (New) 670.37 Covered Porch 54.79 Driveway 2,166.85 1st Floor Conditioned Area 621.56 Other covered or roofed area 189.78 Pool 252.81 Uncovered Patio 70.91 Wood Deck 50% 215.42 Retaining Wall 69.48 Pervious Area 1,028.31 1st Floor Conditioned Area 1,026.37 Pervious Area 905.83 Gravel 588.43 Pervious Area 46.84 Retaining Wall 46.56 Sidewalk 84.44 Sidewalk 44.03 Uncovered Patio 27.35 Sidewalk 11.68 Pervious Area 21.74 Retaining Wall 80.02 Pervious Area 388.02 BUILDING COVERAGE SITE IMPERVIOUS COVER AREA LEVEL TOTAL Sq Ft 1st Floor Conditioned Area FIRST LEVEL 1,969.10 Covered Porch FIRST LEVEL 54.79 Unconditioned (New) FIRST LEVEL 670.37 LOT AREA 10,028.54 2,694.26 ft² SITE COVERAGE AREA LEVEL Total Sq ft Driveway FIRST LEVEL 2,166.85 Retaining Wall FIRST LEVEL 196.05 Sidewalk FIRST LEVEL 210.36 Uncovered Patio FIRST LEVEL 520.15 Wood Deck 50% FIRST LEVEL 725.92 725.92/2=362.96 TOTAL SITE COVERAGE 3,456.37 3,819.33 ft² PERVIOUS AREAS AREA Gravel LEVEL Total Sq ft FIRST LEVEL 863.14 Pervious Area FIRST LEVEL 2,390.73 Pool FIRST LEVEL 252.81 Wood Deck 50% FIRST LEVEL 725.92/2=362.96 725.92 3,869.63 4,232.59 ft² NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION 05/08/2025 3 0 7 8 7 ● s a x e T , n i t s u A ● e c r i l l C e e n w o r B 5 0 7 N W R B I E C N E D S E R T N U - 4 W E N I 1220 Lavaca Street Austin, TX, 78701 WebberStudio.com CURRENT ISSUE CDPROC50 14 May 2025 REVISIONS MARK DATE ISSUE 05.13.25 CDPROC49 PERMIT G101 IMPERVIOUS COVER DIAGRAM 8 OF 117 COPYRIGHT © 2025 WEBBER+STUDIO ARCHITECTS IMPERVIOUS FLOOR PLAN SCALE: 1/8" = 1'-0" 1 N M P 6 3 : 1 | 5 2 0 2 , 4 1 y a M , y a d s e n d e W | # # # # . r e V | Wood Deck 50% 510.50 Sidewalk 70.21 3 0 3 0 5 2 _ N W R B / T O D U T S / 7 2 d a c h c r A I i r o f i c s a B d u o c M B - I l l a c o l . 7 2 d u o c M B I l : l d u o c M B I (S11°17'00"W) (108.26') N06°46'19"E 108.36' Other covered or roofed area 219.00 5'-0" INTERIOR SIDE YARD SETBACK Covered Porch 54.79 Other covered or roofed area 189.78 10' REAR YARD SETBACK POOL (S62°45'00"E) (109.20') N67°11'19"W 108.75' PROPERTY LINE Unconditioned (New) 670.37 1st Floor Conditioned Area 321.16 1st Floor Conditioned Area 621.56 RG DR R Uncovered Wood Deck 421.88 R RG W D 1st Floor Conditioned Area 1,026.37 R D Wood Deck 50% 215.42 K C A B T E S D R A Y T N O R F ' 5 2 5'-0" INTERIOR SIDE YARD SETBACK PROPERTY LINE (S07°26'00"E) (163.54') S11°46'56"E 163.80" ) ' 6 8 . 4 4 ( ) W " 0 0 ' 5 3 ° 7 6 N ( ' 3 0 . 5 4 W " 4 5 ' 8 1 ° 2 7 N Uncovered Wood Deck 27.35 E N I L Y T R E P O R P AREA CALCULATION FIRST LEVEL Name Surface Area 1st Floor Conditioned Area Covered Porch Other covered or roofed area Unconditioned (New) Uncovered Wood Deck Wood Deck 50% 1,969.10 54.79 408.78 670.37 449.23 215.42/2= 215.42 107.71 (S62°45'00"E) (109.20') N67°11'19"W 108.75' OPERTY LINE PR K OL PO D SETBAC 10' REAR YAR (S11°17'00"W) (108.26') N06°46'19"E 108.36' 5'-0" INTERIOR SIDE YARD SETBACK Pool 189.05 Uncovered Wood Deck 740.48 Conditioned (New) 312.69 K C A B T E S D R A Y T N O R F ' 5 2 ) ' 6 8 . 4 4 ( ) W " 0 0 ' 5 3 ° 7 6 N ( ' 3 0 . 5 4 W " 4 5 ' 8 1 ° 2 7 N 5'-0" INTERIOR SIDE YARD SETBACK PROPERTY LINE (S07°26'00"E) (163.54') S11°46'56"E 163.80" E N I L Y T R E P O R P BUILDING AREA DIAGRAM: FIRST LEVEL SCALE: 1/16" = 1'-0" 1 BUILDING AREA DIAGRAM : PENTHOUSE SCALE: 1/16" = 1'-0" 3 Mechanical Cave 114.57 (S11°17'00"W) (108.26') N06°46'19"E 108.36' Covered Wood Deck 265.30 Conditioned (New) 747.53 5'-0" INTERIOR SIDE YARD SETBACK (S62°45'00"E) (109.20') N67°11'19"W 108.75' OPERTY LINE PR K OL PO D SETBAC 10' REAR YAR Retaining Wall 69.48 Pool 233.47 Wood Deck 50% 517.23 Stone Stairs 70.26 5'-0" INTERIOR SIDE YARD SETBACK K C A B T E S D R A Y T N O R F ' 5 2 Conditioned (New) 453.69 Uncovered Wood Deck 70.91 PROPERTY LINE (S07°26'00"E) (163.54') S11°46'56"E 163.80" ) ' 6 8 . 4 4 ( ) W " 0 0 ' 5 3 ° 7 6 N ( ' 3 0 . 5 4 W " 4 5 ' 8 1 ° 2 7 N E N I L Y T R E P O R P AREA CALCULATION BASEMENT Name Surface Area Conditioned (New) Covered Wood Deck Mechanical Cave Pool Retaining Wall Stone Stairs Uncovered Wood Deck Wood Deck 50% 1,201.22 265.30 114.57 233.47 69.48 70.26 70.91 517.23/2= 517.23 258.6 (S62°45'00"E) (109.20') N67°11'19"W 108.75' OPERTY LINE PR K OL PO D SETBAC 10' REAR YAR (S11°17'00"W) (108.26') N06°46'19"E 108.36' CH Conditioned (New) 2,677.06 W / D 5'-0" INTERIOR SIDE YARD SETBACK Uncovered Wood Deck 33.32 K C A B T E S D R A Y T N O R F ' 5 2 ) ' 6 8 . 4 4 ( ) W " 0 0 ' 5 3 ° 7 6 N ( ' 3 0 . 5 4 W " 4 5 ' 8 1 ° 2 7 N Uncovered Wood Deck 409.63 E N I L Y T R E P O R P 5'-0" INTERIOR SIDE YARD SETBACK PROPERTY LINE (S07°26'00"E) (163.54') S11°46'56"E 163.80" BASEMENT BUILDING AREA DIAGRAM SCALE: 1/16" = 1'-0" 0 BUILDING AREA DIAGRAM : SECOND LEVEL SCALE: 1/16" = 1'-0" 2 M P 6 3 : 1 | 5 2 0 2 , 4 1 y a M , y a d s e n d e W | # # # # . r e V | 3 0 3 0 5 2 _ N W R B / T O D U T S / 7 2 d a c h c r A I i r o f i c s a B d u o c M B - I l l a c o l . 7 2 d u o c M B I l : l d u o c M B I AREA CALCULATION ROOF Name Conditioned (New) Pool Uncovered Wood Deck Surface Area 312.69 189.05 740.48 AREA CALCULATION SECOND LEVEL Name Conditioned (New) Uncovered Wood Deck Surface Area 2,677.06 442.96 NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION 05/08/2025 3 0 7 8 7 ● s a x e T , n i t s u A ● e c r i l l C e e n w o r B 5 0 7 N W R B I E C N E D S E R T N U - 4 W E N I 1220 Lavaca Street Austin, TX, 78701 WebberStudio.com CURRENT ISSUE CDPROC50 14 May 2025 REVISIONS MARK DATE ISSUE 05.13.25 CDPROC49 PERMIT G102 BUILDING AREA DIAGRAM 9 OF 117 COPYRIGHT © 2025 WEBBER+STUDIO ARCHITECTS I N O T P E C X E T H G E H M U M X A M I I " 0 - ' 6 4 I T H G E H M U M X A M I " 0 - ' 0 4 UNIT C ROOF DECK UNIT C UNIT C UNIT C GARAGE STAIR C UNIT B STAIR D UNIT C DECK O POOL MAX. HT. EXCEPTIONS +141'-10" SEA LEVEL +558.45' MAX. BLDG. HEIGHT F.F.E MAXIMUM HEIGHT +135'-10" +135'-10" SEA LEVEL +552.45' " 5 - ' 2 1 " 0 - ' 1 1 " 0 - ' 0 1 F.F.E ROOF DECK +123'-5" F.F.E SECOND LEVEL +111'-0" F.F.E FIRST LEVEL +100'-0" SEA LEVEL +516.58' AVERAGE GRADE +95'-10" SEA LEVEL +512.45' F.F.E BASEMENT +90'-0" BUILDING HEIGHT CALCULATIONS GRADES (25-2-3.4.1) HIGHEST GRADE ADJACENT TO BUILDING LOWEST GRADE ADJACENT TO BUILDING AVERAGE OF HIGHEST & LOWEST GRADES HEIGHTS (25-2-3.4) MAXIMUM HEIGHT (MF-3) MAXIMUM ELEVATION (ALLOWED) MAXIMUM ELEVATION (ACTUAL) 516.90' 508.00' 512.45' 40.00' 552.45' 552.38' HEIGHT LIMIT EXCEPTIONS FOR CHIMNEY, ELEVATOR PENTHOUSE & PARAPETS (25-2-531) 46.00' 15% GREATER THAN ZONING DISTRICT HEIGHT LIMIT 558.45' MAXIMUM HEIGHT EXCEPTION ELEVATION 553.50' ACTUAL HEIGHT EXCEPTION ELEVATION LOWEST LEVEL OF FIRE DEPARTMENT ACCESS 518.00' NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION 05/08/2025 506 507 PL PL 2/A314 508 1/A314 507 NEW UNDERGROUND WATER STORAGE TANK 509 510 OUTLINE BUILDING ABOVE 5'-0" INTERIOR SIDE YARD SETBACK F.E.E SLAB 515.58' 511 F.E.E SLAB 515.58' D N F.E.E SLAB 515.58' SLOPE DOWN TIC A M O T U A E T A G 512 512 STAIR D NEW 2 -STORY +PH & BASEMENT FRAME, STONE WD-5 STEPS N02 N03 BORING 2 STORY RE UCTU STR NEIGH ADJ PROPERTY MF-4 ZONING (DUPLEX USE) 703 Brownlee Circle NEW PARKING DECK W/MEP BELOW BUILDING HEIGHT SECTION SCALE: 3/32" = 1'-0" 2 512 513 DR R NEIGHBORING 1 STORY STRUCTURE (S11°17'00"W) (108.26') N06°46'19"E 108.36' 513 514 F.E.E SLAB 516.58' 516.58' OUTLINE BUILDING ABOVE NEW UNIT B 625 SF RG F.E.E UNIT B 516.58' 9'-0" R RG W D NEW UNIT A 1,054 SF R D UNIT C P U F.E.E LOBBY 516.58' UNIT C 619 SF DN UP I A R A T S DN F.E.E GARAGE 515.92' F.E.E DECK 516.58' STAIR C UNIT C DECK 1 515 516.58' NEW PERVIOUS CONCRETE PAVING ASSEMBLY PROPERTY LINE GRVL-1 516 517 517 PP 518 PL PL CO " 0 6'- SLOPE DOWN 518 NEW TYPE 1 DRIVEWAY " 0 - ' 8 1 " 0 - ' 8 1 K C A B T E S D R A Y T N O R F ' 5 2 9'-0" N01 516.58' N D F.E.E UNIT A 516.58' 516.58' 516.58' SLOPE DOWN 9 . 0 8 . 8 8 ' 1 8 ' 5 1 5 " 0 2'- 1 5 8 ' 8 . 8 1 0 ' 8 . 8 1 5 1/A314 2'-0" 4'-0" ) ) ' 6 8 . 4 4 ( ' 3 0 . 5 4 W W " " 4 0 5 0 ' ' 8 5 103.40' 1 3 ° ° 2 7 7 6 N N ( 519.98' STN-1 R 5'-0" 519 REMOVE EXISTING WATER METER AND RELOCATE W/ NEW LINE . I . C " 6 NEW WALK ) . W W W W E N I L Y T R E P O R P . I . C " 2 520 . . I W O R H T D W E L B A R A V ( I I E L C R C E E L N W O R B 3/A314 " 8 - ' 2 " 8 / 7 5 - ' 2 " 8 / 1 3 - ' 4 " 1 1 - ' 1 " 8 - ' " 6 4 - ' 1 " 8 - ' 4 " 1 1 - ' 4 " 2 / 1 8 - ' 9 " 4 / 1 2 - ' 5 " 2 / 1 3 - ' 0 1 510.98' 879 516.58' 875 5'-0" INTERIOR SIDE YARD SETBACK 5 1 6 PROPERTY LINE DN 515 517 (S07°26'00"E) (163.54') S11°46'56"E 163.80" E E E E E G G GATE 5 1 6 518 HIGHEST EXISTING GRADE ADJACENT TO BUILDING ELEV. 516.90' EXISTING GAS LINE 519 520 PL PL CO " 8 / 5 1 1 - ' 4 STAIR B 516.58' 872 N04 N05 2/G103 N06 OUTLINE BUILDING BELOW U P UNIT C DECK 0 SLOPE F.F.E LOWER DECK 506.58' 506.58' F.F.E POOL DECK 10' REAR YARD SETBACK POOL POOL DECK N07 F.F.E POOL DECK 506.58' POOL N08 OUTLINE RETAINING WALL BELOW STN-1 CLAD RETAINING WALL 9 - ' 9 1 ADJ PROPERTY CS-MU-V-CO-NP 1214 W 6th Street (S62°45'00"E) (109.20') N67°11'19"W 108.75' PROPERTY LINE N09 N10 N11 " 2 / 1 3 - ' 0 1 " 8 / 3 8 - ' 9 PP PP PL PL 2/A314 8 0 5 9 0 5 0 1 5 1 1 5 2 1 5 513 514 515 516 517.00' A2 A C1 B C D D1 D2 E F J K M P 6 3 : 1 | 5 2 0 2 , 4 1 y a M , y a d s e n d e W | # # # # . r e V | 3 0 3 0 5 2 _ N W R B / T O D U T S / 7 2 d a c h c r A I i r o f " 8 / 7 0 - ' 7 2 " 8 - ' 2 " 9 - ' 6 " 1 1 - ' 1 " 8 - ' 6 " 4 - ' 1 " 8 - ' 4 " 4 / 3 i c s a B d u o c M B - I l l a c o l . 7 2 d u o c M B I l : l d u o c M B I GRVL-1 WALKWAY 31'-4 3/4" ZONING SITE PLAN SCALE: 1/8" = 1'-0" 1 N NOTE: LEVEL 1 FINISH FLOOR ELEVATION: +516.58' = +516'-7" = +100'-0" 3 0 7 8 7 ● s a x e T , n i t s u A ● e c r i l l C e e n w o r B 5 0 7 N W R B I E C N E D S E R T N U - 4 W E N I 1220 Lavaca Street Austin, TX, 78701 WebberStudio.com CURRENT ISSUE CDPROC50 14 May 2025 REVISIONS MARK DATE ISSUE 05.13.25 CDPROC49 PERMIT G103 BUILDING HEIGHT DIAGRAMS 10 OF 117 COPYRIGHT © 2025 WEBBER+STUDIO ARCHITECTS UNIT C DECK 2 UNIT C DECK 1 STAIR B UNIT A UNIT C ROOF DECK UNIT C UNIT C GARAGE STAIR A ELEV. UNIT C UNIT B FIREBLK STAIR D UNIT C DECK 0 C BUILDING SECTION N-S SCALE: 3/32" = 1'-0" 1 BUILDING SECTION N-S SCALE: 3/32" = 1'-0" 2 FIRE RATED ASSEMBLIES 1-HOUR RATED ASSEMBLY 2-HOUR RATED ASSEMBLY GARAGE CEILING ASSEMBLY NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION 05/08/2025 D N STAIR D U P P U I A R A T S DN UNIT C ELEV. UNIT B SLAB ABOVE UNIT D DECK 0 UNIT D STAIR C UNIT A SLAB ABOVE D N STAIR D U P UNIT C GARAGE P U DN UP I A R A T S DN UNIT C ELEV. DR R RG UNIT B 2/G104 STAIR C R RG UNIT C DECK 1 UNIT A W D R D 1/G104 STAIR B 2/G104 1/G104 N W R B I E C N E D S E R T N U - 4 W E N I CODE PLAN: BASEMENT SCALE: 3/32" = 1'-0" 3 N CODE PLAN: FIRST LEVEL SCALE: 3/32" = 1'-0" 4 N 1220 Lavaca Street Austin, TX, 78701 WebberStudio.com 2/G104 2/G104 DN CH STAIR A UP DN UNIT C ROOF DECK C DN STAIR UP A ELEV. W / D STAIR C UNIT C UNIT C DECK 2 1/G104 STAIR B CODE PLAN: SECOND LEVEL SCALE: 3/32" = 1'-0" 5 N 2/G104 1/G104 CODE PLAN: PENTHOUSE & ROOF DECK SCALE: 3/32" = 1'-0" 6 N 3 0 7 8 7 ● s a x e T , n i t s u A ● e c r i l l C e e n w o r B 5 0 7 CURRENT ISSUE CDPROC50 14 May 2025 REVISIONS MARK DATE ISSUE 05.13.25 CDPROC49 PERMIT G104 FIRE SEPARATION DIAGRAMS 11 OF 117 COPYRIGHT © 2025 WEBBER+STUDIO ARCHITECTS 2/G104 1/G104 M P 6 3 : 1 | 5 2 0 2 , 4 1 y a M , y a d s e n d e W | # # # # . r e V | 3 0 3 0 5 2 _ N W R B / T O D U T S / 7 2 d a c h c r A I i r o f i c s a B d u o c M B - I l l a c o l . 1/G104 7 2 d u o c M B I l : l d u o c M B I 506 507 PL PL 2/A314 508 1/A314 507 ADJ PROPERTY MF-4 ZONING (DUPLEX USE) 703 Brownlee Circle NEW PARKING DECK W/MEP BELOW NEW UNDERGROUND WATER STORAGE TANK 509 510 OUTLINE BUILDING ABOVE 5'-0" INTERIOR SIDE YARD SETBACK F.E.E SLAB 515.58' 511 F.E.E SLAB 515.58' D N F.E.E SLAB 515.58' SLOPE DOWN TIC A M O T U A E T A G 512 512 STAIR D NEW 2 -STORY +PH & BASEMENT FRAME, STONE WD-5 STEPS N02 N03 BORING 2 STORY RE UCTU STR NEIGH UNIT C P U F.E.E LOBBY 516.58' UNIT C 619 SF DN UP I A R A T S DN F.E.E GARAGE 515.92' F.E.E DECK 516.58' STAIR C UNIT C DECK 1 512 513 DR R NEIGHBORING 1 STORY STRUCTURE (S11°17'00"W) (108.26') N06°46'19"E 108.36' 513 514 F.E.E SLAB 516.58' 516.58' OUTLINE BUILDING ABOVE NEW UNIT B 625 SF RG F.E.E UNIT B 516.58' 9'-0" R RG W D NEW UNIT A 1,054 SF R D F.E.E UNIT A 516.58' 516.58' 516.58' 515 516.58' NEW PERVIOUS CONCRETE PAVING ASSEMBLY PROPERTY LINE GRVL-1 516 517 517 PP 518 PL PL CO " 0 6'- SLOPE DOWN 518 NEW TYPE 1 DRIVEWAY " 0 - ' 8 1 " 0 - ' 8 1 K C A B T E S D R A Y T N O R F ' 5 2 9'-0" N01 516.58' N D SLOPE DOWN 9 . 0 8 . 8 8 ' 1 8 ' 5 1 5 " 0 2'- 1 5 2'-0" 4'-0" 8 ' 8 . 8 1 0 ' 8 . 8 1 5 1/A314 NEW WALK ) . STN-1 R 5'-0" 519 ) ) ' 6 8 . 4 4 ( ' 3 0 . 5 4 W W " " 4 0 5 0 ' ' 8 5 103.40' 1 3 ° ° 2 7 7 6 N N ( 519.98' REMOVE EXISTING WATER METERS & INSTALL NEW SERVICE & METERS W W W . I . C " 6 . I . C " 2 520 E N I L Y T R E P O R P . . I W O R H T D W E L B A R A V ( I I E L C R C E E L N W O R B 3/A314 " 8 - ' 2 " 8 / 7 5 - ' 2 " 8 / 1 3 - ' 4 " 1 1 - ' 1 " 8 - ' " 6 4 - ' 1 " 8 - ' 4 " 1 1 - ' 4 " 2 / 1 8 - ' 9 " 4 / 1 2 - ' 5 " 2 / 1 3 - ' 0 1 510.98' 879 516.58' 875 5'-0" INTERIOR SIDE YARD SETBACK 5 1 6 PROPERTY LINE DN 515 517 (S07°26'00"E) (163.54') S11°46'56"E 163.80" E E E E E G G GATE 5 1 6 518 HIGHEST EXISTING GRADE ADJACENT TO BUILDING ELEV. 516.90' EXISTING GAS LINE 519 520 PL PL CO " 8 / 5 1 1 - ' 4 STAIR B 516.58' 872 N04 N05 2/G103 N06 OUTLINE BUILDING BELOW U P UNIT C DECK 0 SLOPE F.F.E LOWER DECK 506.58' 506.58' F.F.E POOL DECK 10' REAR YARD SETBACK POOL POOL DECK N07 F.F.E POOL DECK 506.58' POOL N08 OUTLINE RETAINING WALL BELOW STN-1 CLAD RETAINING WALL 9 - ' 9 1 ADJ PROPERTY CS-MU-V-CO-NP 1214 W 6th Street (S62°45'00"E) (109.20') N67°11'19"W 108.75' PROPERTY LINE N09 N10 N11 " 2 / 1 3 - ' 0 1 " 8 / 3 8 - ' 9 PP PP PL PL 2/A314 8 0 5 9 0 5 0 1 5 1 1 5 2 1 5 513 514 515 516 517.00' GRVL-1 WALKWAY 31'-4 3/4" ACCESSIBILITY SITE PLAN SCALE: 1/8" = 1'-0" 1 N " 8 / 7 0 - ' 7 2 " 8 - ' 2 " 9 - ' 6 " 1 1 - ' 1 " 8 - ' 6 " 4 - ' 1 " 8 - ' 4 " 4 / 3 A2 A C1 B C D D1 D2 E F J K M P 6 3 : 1 | 5 2 0 2 , 4 1 y a M , y a d s e n d e W | # # # # . r e V | 3 0 3 0 5 2 _ N W R B / T O D U T S / 7 2 d a c h c r A I i r o f i c s a B d u o c M B - I l l a c o l . 7 2 d u o c M B I l : l d u o c M B I NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION 05/08/2025 3 0 7 8 7 ● s a x e T , n i t s u A ● e c r i l l C e e n w o r B 5 0 7 N W R B I E C N E D S E R T N U - 4 W E N I 1220 Lavaca Street Austin, TX, 78701 WebberStudio.com CURRENT ISSUE CDPROC50 14 May 2025 REVISIONS MARK DATE ISSUE 05.13.25 CDPROC49 PERMIT G106 ACCESSIBILITY INFORMATION - SITE 13 OF 117 COPYRIGHT © 2025 WEBBER+STUDIO ARCHITECTS LEGEND NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION ACCESSIBLE ROUTE 05/08/2025 DN UP DR R R RG RG W D R D N W R B 3 0 7 8 7 ● s a x e T , n i t s u A ● e c r i l l C e e n w o r B 5 0 7 I E C N E D S E R T N U - 4 W E N I ACCESSIBILITY PLAN: FIRST LEVEL SCALE: 3/32" = 1'-0" 1 N ACCESSIBILITY PLAN: PENTHOUSE & ROOF DECK SCALE: 3/32" = 1'-0" 3 N 1220 Lavaca Street Austin, TX, 78701 WebberStudio.com M P 6 3 : 1 | 5 2 0 2 , 4 1 y a M , y a d s e n d e W | # # # # . r e V | 3 0 3 0 5 2 _ N W R B / T O D U T S / 7 2 d a c h c r A I i r o f i c s a B d u o c M B - I l l a c o l . 1/G104 7 2 d u o c M B I l : l d u o c M B I STAIR D 2/G104 UNIT D DECK 0 UNIT D ELEV. UNIT B SLAB ABOVE UNIT A SLAB ABOVE DN DN CH UP W / D 2/G104 1/G104 ACCESSIBILITY PLAN: BASEMENT SCALE: 3/32" = 1'-0" 0 N ACCESSIBILITY PLAN: SECOND LEVEL SCALE: 3/32" = 1'-0" 2 N CURRENT ISSUE CDPROC50 14 May 2025 REVISIONS MARK DATE ISSUE 05.13.25 CDPROC49 PERMIT G107 ACCESSIBILITY INFORMATION - BUILDING 14 OF 117 COPYRIGHT © 2025 WEBBER+STUDIO ARCHITECTS 874 D-03 877 876 D-07 D-02 D-01 SIDE SETBACK 5'-0" 1 D101 D-09 D-02 D-01 D-06 EXISTING PORCHE D-05 CARPORT FREF UNIT B D-09 D10 E L C H R.O.W.) E CIR E WID T E L N W L O B R RIA B A (V PP CO D-03 D-14 D-15 D-16 W W . I . C " 6 . I . C " 2 " 0 - ' 5 2 K C A B T E S T N O R F D-03 878 D-02 REAR SETBACK 10'-0" M P 6 3 : 1 | 5 2 0 2 , 4 1 y a M , y a d s e n d e W | # # # # . r e V | D-04 879 D-04 D-08 D-11 D-10 UNIT A CO 875 EXISTING WOOD DECK F E R D-04 872 D-08 E E E E LINE OF ROOF ABOVE G G SIDE SETBACK 5'-0" D-07 PP D-12 D-13 CO DEMOLITION SITE PLAN SCALE: 1/8" = 1'-0" 1 N 3 0 3 0 5 2 _ N W R B / T O D U T S / 7 2 d a c h c r A I i r o f i c s a B d u o c M B - I l l a c o l . 7 2 d u o c M B I l : l d u o c M B I LEGEND PROPERTY LINE SET BACK LINE TREE (C.R.Z) CANOPY LINE OVERHEAD UTILITY LINE GAS LINE WATER LINE ELECTRIC LINE WOOD BOARD FENCE CHAIN LINK FENCE WIRE AND WOOD FENCE GAS METER ELECTRIC METER WATER METERS; (2) IN BOX CLEAN OUT AIR CONDITIONER POWER POLE WATER VALVE IRRIGATION CONTROL VALVE FIRE HYDRANT TREE LIST ID 872 873 874 875 876 877 878 879 Ø TYPE 16.5" LIVE OAK 13.5"X8.5" HACKBERRY 10.5" PECAN 18" MESQUITE 14" HACKBERRY 21" HACKBERRY 12" HACKBERRY 25" PECAN NOTE (M) KEEP/ REMOVE KEEP REMOVE REMOVE KEEP REMOVE (P) REMOVED PRIOR (P)(H) REMOVE KEEP GENERAL DEMOLITION NOTES GENERAL NOTES: 1. DEMOLITION PERMIT TO BE OBTAINED PRIOR TO START OF ANY SITE WORK, DEMOLITION, OR EXCAVATION. 2. COORDINATE LOCATION OF ONSITE UNDERGROUND UTILITIES PRIOR TO START OF ANY SITE WORK, DEMOLITION, OR EXCAVATION. 3. COORDINATE UTILITY SHUT-OFF PRIOR TO START OF ANY SITE WORK, DEMOLITION, OR EXCAVATION. 4. TREE PROTECTION SHALL BE INSTALLED PRIOR TO START OF ANY SITE WORK, INCLUDING DEMOLITION OR SITE PREPARATION, AND MAINTAINED CONTINUOUSLY THROUGHOUT THE DURATION OF CONSTRUCTION. TREE PROTECTION REQUIREMENTS AND SPECIFICATIONS TO ABIDE BY LOCAL MUNICIPAL CODE. 5. ALL DEMOLITION DEBRIS AND WASTE TO BE PROPERLY DISPOSED IN FULL COMPLIANCE OF ALL LAWS AND LOCAL MUNICIPAL CODE. 6. REMOVE EXISTING SANITARY SEWER LINES(S) WHICH WILL NOT BE REUSED AT 1606 & 1608 & CAP MAIN NOT TO BE REUSED. 7. EXISTING TV CABLE, PHONE & INTERNET LINES TO BE REMOVED & REPURPOSED (IF FEASIBLE). 8. EXISTING TREES TO REMAIN UNDISTURBED UNO - SEE PROTECTION NOTE. 9. REMOVE BRICK FOR REUSE ELSEWHERE 10. REMOVE LUMBER FOR REUSE IN NEW CONSTRUCTION 11. REMOVE CONCRETE SLAB IN IT'S ENTIRETY 12. CAP EXISTING WATER & WASTEWATER LINES TO BE REUSED 13. REMOVE APPLIANCES & FIXTURES FOR REUSE IN NEW CONSTRUCTION DEMOLITION KEYNOTES SITE WORK ID DESCRIPTION D-01 EXISTING FLATWORK/SLAB TO BE REMOVED AFTER USE AS STAGING D-02 D-03 D-04 EXISTING FENCE TO BE REMOVED EXISTING RETAINING WALL TO BE REMOVED AS REQUIRED EXISTING TREE TO REMAIN UNDISTURBED. SEE PROTECTION NOTE D-05 EXCAVATION AREA FOR NEW POOL D-06 REMOVE EXISTING SHED & CARPORT D-07 REMOVE OVERHEAD ELECTRICAL LINE D-08 REMOVE WOOD STAIR D-09 REMOVE CONCRETE STAIR D-10 REMOVE EXISTING DUPLEX RESIDENCE & CONC. SLAB D-11 REMOVE EXISTING WOOD DECK & RAILINGS D-12 REMOVE EXISTING ELECTRIC METER, DISCONNECT & PANELS D-13 REMOVE EXISTING GAS METERS & CAP LINE AS REQUIRED D-14 REMOVE EXISTING WASTEWATER CLEANOUT IN CONC D-15 REMOVE EXISTING CONC. DRIVEWAY APRON D-16 REMOVE EXISTING WATER METER & CAP LINE AS REQUIRED NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION 05/08/2025 3 0 7 8 7 ● s a x e T , n i t s u A ● e c r i l l C e e n w o r B 5 0 7 N W R B I E C N E D S E R T N U - 4 W E N I 1220 Lavaca Street Austin, TX, 78701 WebberStudio.com CURRENT ISSUE CDPROC50 14 May 2025 REVISIONS MARK DATE ISSUE 05.13.25 CDPROC49 PERMIT D001 DEMOLITION SITE PLAN 16 OF 117 COPYRIGHT © 2025 WEBBER+STUDIO ARCHITECTS LEGEND PROPERTY LINE SET BACK LINE TREE (C.R.Z) CANOPY LINE OVERHEAD UTILITY LINE GAS LINE WATER LINE ELECTRIC LINE WOOD BOARD FENCE CHAIN LINK FENCE WIRE AND WOOD FENCE GAS METER ELECTRIC METER WATER METER CLEAN OUT AIR CONDITIONER POWER POLE WATER VALVE IRRIGATION CONTROL VALVE FIRE HYDRANT TREE LIST ID 872 873 874 875 876 877 878 879 Ø TYPE 16.5" LIVE OAK 13.5"X8.5" HACKBERRY 10.5" PECAN 18" MESQUITE 14" HACKBERRY 21" HACKBERRY 12" HACKBERRY 25" PECAN NOTE (M) (P) KEEP/ REMOVE KEEP REMOVE REMOVE KEEP REMOVE REMOVE REMOVE (P)(H) KEEP GENERAL DEMOLITION NOTES GENERAL NOTES: 1. DEMOLITION PERMIT TO BE OBTAINED PRIOR TO START OF ANY SITE WORK, DEMOLITION, OR EXCAVATION. 2. COORDINATE LOCATION OF ONSITE UNDERGROUND UTILITIES PRIOR TO START OF ANY SITE WORK, DEMOLITION, OR EXCAVATION. 3. COORDINATE UTILITY SHUT-OFF PRIOR TO START OF ANY SITE WORK, DEMOLITION, OR EXCAVATION. 4. TREE PROTECTION SHALL BE INSTALLED PRIOR TO START OF ANY SITE WORK, INCLUDING DEMOLITION OR SITE PREPARATION, AND MAINTAINED CONTINUOUSLY THROUGHOUT THE DURATION OF CONSTRUCTION. TREE PROTECTION REQUIREMENTS AND SPECIFICATIONS TO ABIDE BY LOCAL MUNICIPAL CODE. 5. ALL DEMOLITION DEBRIS AND WASTE TO BE PROPERLY DISPOSED IN FULL COMPLIANCE OF ALL LAWS AND LOCAL MUNICIPAL CODE. 6. REMOVE EXISTING SANITARY SEWER LINES(S) WHICH WILL NOT BE REUSED AT 1606 & 1608 & CAP MAIN NOT TO BE REUSED. 7. EXISTING TV CABLE, PHONE & INTERNET LINES TO BE REMOVED & REPURPOSED (IF FEASIBLE). 8. EXISTING TREES TO REMAIN UNDISTURBED UNO - SEE PROTECTION NOTE. 9. REMOVE BRICK FOR REUSE ELSEWHERE 10. REMOVE LUMBER FOR REUSE IN NEW CONSTRUCTION 11. REMOVE CONCRETE SLAB IN IT'S ENTIRETY 12. CAP EXISTING WATER & WASTEWATER LINES TO BE REUSED 13. REMOVE APPLIANCES & FIXTURES FOR REUSE IN NEW CONSTRUCTION DEMOLITION KEYNOTES SITE WORK ID DESCRIPTION D-01 EXISTING FLATWORK/SLAB TO BE REMOVED D-02 EXISTING FENCE TO BE REMOVED D-03 EXISTING RETAINING WALL CUT TO BE REMOVED D-04 EXISTING TREE TO REMAIN UNDISTURBED. SEE PROTECTION NOTE D-05 EXCAVATION AREA FOR NEW POOL D-06 REMOVE EXISTING SHED & CARPORT D-07 REMOVE OVERHEAD ELECTRICAL LINE D-08 REMOVE WOOD STAIR D-09 REMOVE CONCRETE STAIR D-10 REMOVE EXISTING DUPLEX RESIDENCE & CONC. SLAB D-11 REMOVE EXISTING WOOD DECK & RAILINGS D-12 REMOVE EXISTING ELECTRIC METER, DISCONNECT & PANELS D-13 REMOVE EXISTING GAS METERS & CAP LINE AS REQUIRED D-14 REMOVE EXISTING WASTEWATER CLEANOUT IN CONC D-15 REMOVE EXISTING CONC. DRIVEWAY APRON D-09 FREF EXISTING PORCHE D10 CO D-14 D-08 D-11 875 EXISTING WOOD DECK D-12 F E R D-08 E E E E LINE OF ROOF ABOVE G G D-12 D-13 DEMOLITION PLAN : 1st FLOOR SCALE: 1/4" = 1'-0" 1 N NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION 05/08/2025 3 0 7 8 7 ● s a x e T , n i t s u A ● e c r i l l C e e n w o r B 5 0 7 N W R B I E C N E D S E R T N U - 4 W E N I 1220 Lavaca Street Austin, TX, 78701 WebberStudio.com CURRENT ISSUE CDPROC50 14 May 2025 REVISIONS MARK DATE ISSUE 05.13.25 CDPROC49 PERMIT D101 DEMOLITION PLAN : 1st FLOOR 17 OF 117 COPYRIGHT © 2025 WEBBER+STUDIO ARCHITECTS M P 6 3 : 1 | 5 2 0 2 , 4 1 y a M , y a d s e n d e W | # # # # . r e V | 3 0 3 0 5 2 _ N W R B / T O D U T S / 7 2 d a c h c r A I i r o f i c s a B d u o c M B - I l l a c o l . 7 2 d u o c M B I l : l d u o c M B I LEGEND PROPERTY LINE SET BACK LINE TREE (C.R.Z) CANOPY LINE OVERHEAD UTILITY LINE GAS LINE WATER LINE ELECTRIC LINE WOOD BOARD FENCE CHAIN LINK FENCE WIRE AND WOOD FENCE GAS METER ELECTRIC METER WATER METER CLEAN OUT AIR CONDITIONER POWER POLE WATER VALVE IRRIGATION CONTROL VALVE FIRE HYDRANT TREE LIST ID 872 873 874 875 876 877 878 879 Ø TYPE 16.5" LIVE OAK 13.5"X8.5" HACKBERRY 10.5" PECAN 18" MESQUITE 14" HACKBERRY 21" HACKBERRY 12" HACKBERRY 25" PECAN NOTE (M) (P) KEEP/ REMOVE KEEP REMOVE REMOVE KEEP REMOVE REMOVE REMOVE (P)(H) KEEP GENERAL DEMOLITION NOTES GENERAL NOTES: 1. DEMOLITION PERMIT TO BE OBTAINED PRIOR TO START OF ANY SITE WORK, DEMOLITION, OR EXCAVATION. 2. COORDINATE LOCATION OF ONSITE UNDERGROUND UTILITIES PRIOR TO START OF ANY SITE WORK, DEMOLITION, OR EXCAVATION. 3. COORDINATE UTILITY SHUT-OFF PRIOR TO START OF ANY SITE WORK, DEMOLITION, OR EXCAVATION. 4. TREE PROTECTION SHALL BE INSTALLED PRIOR TO START OF ANY SITE WORK, INCLUDING DEMOLITION OR SITE PREPARATION, AND MAINTAINED CONTINUOUSLY THROUGHOUT THE DURATION OF CONSTRUCTION. TREE PROTECTION REQUIREMENTS AND SPECIFICATIONS TO ABIDE BY LOCAL MUNICIPAL CODE. 5. ALL DEMOLITION DEBRIS AND WASTE TO BE PROPERLY DISPOSED IN FULL COMPLIANCE OF ALL LAWS AND LOCAL MUNICIPAL CODE. 6. REMOVE EXISTING SANITARY SEWER LINES(S) WHICH WILL NOT BE REUSED AT 1606 & 1608 & CAP MAIN NOT TO BE REUSED. 7. EXISTING TV CABLE, PHONE & INTERNET LINES TO BE REMOVED & REPURPOSED (IF FEASIBLE). 8. EXISTING TREES TO REMAIN UNDISTURBED UNO - SEE PROTECTION NOTE. 9. REMOVE BRICK FOR REUSE ELSEWHERE 10. REMOVE LUMBER FOR REUSE IN NEW CONSTRUCTION 11. REMOVE CONCRETE SLAB IN IT'S ENTIRETY 12. CAP EXISTING WATER & WASTEWATER LINES TO BE REUSED 13. REMOVE APPLIANCES & FIXTURES FOR REUSE IN NEW CONSTRUCTION DEMOLITION KEYNOTES SITE WORK ID DESCRIPTION D-01 EXISTING FLATWORK/SLAB TO BE REMOVED D-02 EXISTING FENCE TO BE REMOVED D-03 EXISTING RETAINING WALL CUT TO BE REMOVED D-04 EXISTING TREE TO REMAIN UNDISTURBED. SEE PROTECTION NOTE D-05 EXCAVATION AREA FOR NEW POOL D-06 REMOVE EXISTING SHED & CARPORT D-07 REMOVE OVERHEAD ELECTRICAL LINE D-08 REMOVE WOOD STAIR D-09 REMOVE CONCRETE STAIR D-10 REMOVE EXISTING DUPLEX RESIDENCE & CONC. SLAB D-11 REMOVE EXISTING WOOD DECK & RAILINGS D-12 REMOVE EXISTING ELECTRIC METER, DISCONNECT & PANELS D-13 REMOVE EXISTING GAS METERS & CAP LINE AS REQUIRED D-14 REMOVE EXISTING WASTEWATER CLEANOUT IN CONC D-15 REMOVE EXISTING CONC. DRIVEWAY APRON D-13 D-13 I W O L E B E N L G N D L U B I I BUILDING LINE BELOW D-13 SLOPE SLOPE E P O L S E P O L S E P O L S E P O L S BUILDING LINE BELOW D-13 I W O L E B E N L G N D L U B I I M P 6 3 : 1 | 5 2 0 2 , 4 1 y a M , y a d s e n d e W | # # # # . r e V | 3 0 3 0 5 2 _ N W R B / T O D U T S / 7 2 d a c h c r A I i r o f i c s a B d u o c M B - I l l a c o l . 7 2 d u o c M B I l : DEMOLITION PLAN : ROOF SCALE: 1/4" = 1'-0" 1 N l d u o c M B I NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION 05/08/2025 3 0 7 8 7 ● s a x e T , n i t s u A ● e c r i l l C e e n w o r B 5 0 7 N W R B I E C N E D S E R T N U - 4 W E N I 1220 Lavaca Street Austin, TX, 78701 WebberStudio.com CURRENT ISSUE CDPROC50 14 May 2025 REVISIONS MARK DATE ISSUE 05.13.25 CDPROC49 PERMIT D102 DEMOLITION PLAN : ROOF 18 OF 117 COPYRIGHT © 2025 WEBBER+STUDIO ARCHITECTS 12'-8 1/8" 12'-2 5/8" 16'-1 1/4" D N STAIR D 6'-1 1/2" 60'-9 3/4" (S11°17'00"W) (108.26') N06°46´19'E 108.36' 5'-0" SIDE SETBACK DRIVEWAY P U UP CH POOL UNIT C ROOF DECK PENTHOUSE ROOF DN W / D UNIT C DECK 1 879 875 DN DR R RG ROOF R RG W D ROOF R D 4'-2 1/8" (S62°45'00"E) (109.20') N67°11´19'W 108.75' U P K 10'-0" REAR SETBAC POOL 63'-6 7/8" 22'-10 5/8" 2'-3 1/2" 16'-2 7/8" K C A B T E S T N O R F " 0 - ' 5 2 N01 44'-2 1/2" 7'-9 3/8" 12'-1 7/8" 27'-11 5/8" 41'-10 1/4" 29'-9 1/4" DECK SECOND FLOOR STAIR B 872 5'-0" SIDE SETBACK S11°46'56"E (163.80') (S07°26'00"E) (163.54') M P 6 3 : 1 | 5 2 0 2 , 4 1 y a M , y a d s e n d e W | # # # # . r e V | 3 0 3 0 5 2 _ N W R B / T O D U T S / 7 2 d a c h c r A I i r o f i c s a B d u o c M B - I l l a c o l . 7 2 d u o c M B I l : l d u o c M B I SITE / LOT PLAN LEGEND PROPERTY LINE SET BACK LINE TREE (C.R.Z) CANOPY LINE OVERHEAD UTILITY LINE GAS LINE WATER LINE ELECTRIC LINE WOOD BOARD FENCE CHAIN LINK FENCE WIRE AND WOOD FENCE GAS METER ELECTRIC METER WATER METERS; (2) IN BOX CLEAN OUT AIR CONDITIONER POWER POLE WATER VALVE IRRIGATION CONTROL VALVE FIRE HYDRANT G E W CO PP WV PP Y D H TREE PROTECTION NOTES 12 GA. WIRE (OR STRAPS) STAPLED TO 2X6s. THIS METHOD PROTECTS TRUNK FROM DAMAGE BY CONSTRUCTION EQUIPMENT. IT DOES NOT PROTECT ROOTS FROM COMPACTION. BARRIER SHOULD EXTEND THE FULL DIAMETER OF THE TREE CROWN TREE TRUNK PROTECTION GALV'D CHAIN LINK FENCE MATERIAL SUPPORTED BY GALV'D MTL FENCE POSTS OR EQUIVALENT CONSTRUCTION FENCE. THIS METHOD PROTECTS TREE FROM ROOT COMPACTION FROM CONSTRUCTION EQUIPMENT. " 0 - ' 6 D E D N E M M O C E R TREE PROTECTION BARRIER IT IS THE ARCHITECT'S AND OWNER'S INTENT TO PROTECT ALL TREES IN PROXIMITY TO CONSTRUCTION AREA FROM DAMAGE OR INJURY DUE TO CONSTRUCTION. THE SUGGESTIONS FOR TREE PROTECTION PROVIDED ABOVE ARE EXPLICITLY NOT GUARANTEED TO FULLY PROTECT THE TREES. IT IS HIGHLY RECOMMENDED THAT A TREE SPECIALIST BE HIRED AND THAT SUCH COST BE REVIEWED WITH OWNER FOR APPROVAL PRIOR TO PROCUREMENT OF TREE SPECIALIST SERVICES. IF CONTRACTOR DOES NOT REVIEW WITH OWNER HIS OR HER WILLINGNESS OR NON- WILLINGNESS TO HIRE SUCH SPECIALIST, THEN IT WILL BE CONSTRUED AS CONTRACTOR'S WILLINGNESS TO ACCEPT LIABILITY FOR PROTECTING THE TREES FROM ANY DAMAGE THROUGHOUT THE CONSTRUCTION PROCESS. NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION 05/08/2025 3 0 7 8 7 ● s a x e T , n i t s u A ● e c r i l l C e e n w o r B 5 0 7 N W R B I E C N E D S E R T N U - 4 W E N I E L C H R.O.W.) T E CIR E WID E L N W L O B R RIA B A (V EXAMPLE: 20 IN. DIAMETER TREE 1/4 CRZ 5'-0" 1/2 CRZ 10'-0" FULL CRZ 20'-0" 1220 Lavaca Street Austin, TX, 78701 WebberStudio.com 1/4 CRZ - NO IMPACT 1/2 CRZ - NO CUT/FILL > 4" FULL CRZ - PRESERVE 50% CITY CODE REQUIRES THAT PROPOSED DEVELOPMENTS DEMONSTRATE THAT TREES ARE PRESERVED TO THE MAXIMUM EXTENT REASONABLE AND FEASIBLE. TREE PRESERVATION IS EFFECTIVELY DEFINED AS ROOT SYSTEM PRESERVATION; A CRITICAL ROOT ZONE AREA (CRZ) IS ASSIGNED TO EACH TREE, BASED ON TRUNK DIAMETER SIZE. A MINIMUM OF 50% OF THE CRZ IS REQUIRED TO BE LEFT UNDISTURBED TO ACHIEVE MINIMAL CONFORMANCE WITH THE REGULATIONS. LEGAL DESCRIPTION PROJECT ADDRESS: 705 Brownlee Circle Austin Texas 78703 U.S.A. LEGAL DESCRIPTION: LOT 32 OF PARK VIEW, VOLUME 5, PAGE 69, PLAT RECORDS, TRAVIS CO.,TX DESCRIPTION OF WORK: DEMOLITION OF EXISTING DUPLEX AND CONSTRUCTION OF NEW 4-UNIT RESIDENCE OWNER'S NAME: BRAD HOSKINS & MELISSA SKIDMORE TREE LIST 872 875 879 N01 N02 N03 N04 N05 N06 N07 N08 N09 N10 N11 16.5" LIVE OAK 18" MESQUITE 25" PECAN TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD CURRENT ISSUE CDPROC50 14 May 2025 REVISIONS MARK DATE ISSUE 05.13.25 CDPROC49 PERMIT SP101 LOT PLAN 19 OF 117 COPYRIGHT © 2025 WEBBER+STUDIO ARCHITECTS LOT PLAN SCALE: 1/8" = 1'-0" 1 N " 8 / 7 5 - ' 2 " 1 1 - ' 8 2 " 8 / 5 8 - ' 7 " 4 / 3 7 - ' 5 1 (A: 55.78') (R: 95.99') (D: 33°17'44" CB: (N83°44'00"E) (CL: 55.00') A: 55.83' R: 95.99' D: 33°19'33" CB: N78°55'09"E CL: 55.05' 2 2.4 3 4 5 6 7 18'-10 1/2" 6'-0" 8'-2 1/4" 24'-0 5/8" 11'-9 5/8" 2'-10 1/4" 2'-0" 29'-8 1/4" 1.5 1 1.75 506 507 PL PL 2/A314 508 1/A314 507 ADJ PROPERTY MF-4 ZONING (DUPLEX USE) 703 Brownlee Circle NEW PARKING DECK W/MEP BELOW NEW UNDERGROUND WATER STORAGE TANK 509 510 OUTLINE BUILDING ABOVE 5'-0" INTERIOR SIDE YARD SETBACK F.E.E SLAB 515.58' 511 F.E.E SLAB 515.58' D N F.E.E SLAB 515.58' SLOPE DOWN TIC A M O T U A E T A G 512 512 STAIR D NEW 2 -STORY +PH & BASEMENT FRAME, STONE WD-5 STEPS N02 N03 BORING 2 STORY RE UCTU STR NEIGH UNIT C P U F.E.E LOBBY 516.58' UNIT C 619 SF DN UP I A R A T S DN F.E.E GARAGE 515.92' F.E.E DECK 516.58' STAIR C UNIT C DECK 1 512 513 DR R NEIGHBORING 1 STORY STRUCTURE (S11°17'00"W) (108.26') N06°46'19"E 108.36' 513 514 F.E.E SLAB 516.58' 516.58' OUTLINE BUILDING ABOVE NEW UNIT B 625 SF RG F.E.E UNIT B 516.58' 9'-0" R RG W D NEW UNIT A 1,054 SF R D F.E.E UNIT A 516.58' 516.58' 516.58' 515 516.58' NEW PERVIOUS CONCRETE PAVING ASSEMBLY PROPERTY LINE GRVL-1 516 517 517 PP 518 PL PL CO " 0 6'- SLOPE DOWN 518 NEW TYPE 1 DRIVEWAY " 0 - ' 8 1 " 0 - ' 8 1 K C A B T E S D R A Y T N O R F ' 5 2 9'-0" N01 516.58' N D SLOPE DOWN 9 . 0 8 . 8 8 ' 1 8 ' 5 1 5 " 0 2'- 1 5 2'-0" 4'-0" 8 ' 8 . 8 1 0 ' 8 . 8 1 5 1/A314 NEW WALK ) . STN-1 R 5'-0" 519 ) ) ' 6 8 . 4 4 ( ' 3 0 . 5 4 W W " " 4 0 5 0 ' ' 8 5 103.40' 1 3 ° ° 2 7 7 6 N N ( 519.98' REMOVE EXISTING WATER METERS & INSTALL NEW SERVICE & METERS W W W . I . C " 6 . I . C " 2 520 E N I L Y T R E P O R P . . I W O R H T D W E L B A R A V ( I I E L C R C E E L N W O R B 3/A314 510.98' 879 516.58' 875 5'-0" INTERIOR SIDE YARD SETBACK 5 1 6 PROPERTY LINE DN 515 517 (S07°26'00"E) (163.54') S11°46'56"E 163.80" E E E E E G G GATE 5 1 6 518 HIGHEST EXISTING GRADE ADJACENT TO BUILDING ELEV. 516.90' EXISTING GAS LINE 519 520 PL PL CO " 8 / 5 1 1 - ' 4 STAIR B 516.58' 872 GRVL-1 WALKWAY 31'-4 3/4" N04 N05 2/G103 N06 OUTLINE BUILDING BELOW U P UNIT C DECK 0 SLOPE F.F.E LOWER DECK 506.58' 506.58' F.F.E POOL DECK 10' REAR YARD SETBACK POOL POOL DECK N07 F.F.E POOL DECK 506.58' POOL N08 OUTLINE RETAINING WALL BELOW STN-1 CLAD RETAINING WALL 9 - ' 9 1 ADJ PROPERTY CS-MU-V-CO-NP 1214 W 6th Street (S62°45'00"E) (109.20') N67°11'19"W 108.75' PROPERTY LINE N09 N10 N11 " 2 / 1 3 - ' 0 1 " 8 / 3 8 - ' 9 PP PP PL PL 2/A314 8 0 5 9 0 5 0 1 5 1 1 5 2 1 5 513 514 515 516 517.00' 1 1.75 2 2.4 3 4 5 6 7 C1 A2 78'-7 1/4" 6'-0" 8'-2 1/4" 24'-0 5/8" 11'-9 5/8" 2'-10 1/4" 2'-0" 30'-3" ADJ PROPERTY MF-4 ZONING DUPLEX USE 707 Brownlee Circle ARCHITECTURAL SITE PLAN SCALE: 1/8" = 1'-0" 1 N NOTE: LEVEL 1 FINISH FLOOR ELEVATION: +516.58' = +516'-7" = +100'-0" PP " 8 - ' 2 " 8 / 7 5 - ' 2 " 8 / 1 3 - ' 4 " 1 1 - ' 1 " 8 - ' " 6 4 - ' 1 " 8 - ' 4 " 1 1 - ' 4 " 2 / 1 8 - ' 9 " 4 / 1 2 - ' 5 " 2 / 1 3 - ' 0 1 B C D D1 D2 E F G A H J K SITE / LOT PLAN LEGEND PROPERTY LINE SET BACK LINE TREE (C.R.Z) CANOPY LINE OVERHEAD UTILITY LINE GAS LINE WATER LINE ELECTRIC LINE WOOD BOARD FENCE CHAIN LINK FENCE WIRE AND WOOD FENCE GAS METER ELECTRIC METER WATER METERS; (2) IN BOX CLEAN OUT AIR CONDITIONER POWER POLE WATER VALVE IRRIGATION CONTROL VALVE FIRE HYDRANT G E W CO PP WV PP Y D H TREE PROTECTION NOTES 12 GA. WIRE (OR STRAPS) STAPLED TO 2X6s. THIS METHOD PROTECTS TRUNK FROM DAMAGE BY CONSTRUCTION EQUIPMENT. IT DOES NOT PROTECT ROOTS FROM COMPACTION. BARRIER SHOULD EXTEND THE FULL DIAMETER OF THE TREE CROWN TREE TRUNK PROTECTION GALV'D CHAIN LINK FENCE MATERIAL SUPPORTED BY GALV'D MTL FENCE POSTS OR EQUIVALENT CONSTRUCTION FENCE. THIS METHOD PROTECTS TREE FROM ROOT COMPACTION FROM CONSTRUCTION EQUIPMENT. " 0 - ' 6 D E D N E M M O C E R TREE PROTECTION BARRIER IT IS THE ARCHITECT'S AND OWNER'S INTENT TO PROTECT ALL TREES IN PROXIMITY TO CONSTRUCTION AREA FROM DAMAGE OR INJURY DUE TO CONSTRUCTION. THE SUGGESTIONS FOR TREE PROTECTION PROVIDED ABOVE ARE EXPLICITLY NOT GUARANTEED TO FULLY PROTECT THE TREES. IT IS HIGHLY RECOMMENDED THAT A TREE SPECIALIST BE HIRED AND THAT SUCH COST BE REVIEWED WITH OWNER FOR APPROVAL PRIOR TO PROCUREMENT OF TREE SPECIALIST SERVICES. IF CONTRACTOR DOES NOT REVIEW WITH OWNER HIS OR HER WILLINGNESS OR NON- WILLINGNESS TO HIRE SUCH SPECIALIST, THEN IT WILL BE CONSTRUED AS CONTRACTOR'S WILLINGNESS TO ACCEPT LIABILITY FOR PROTECTING THE TREES FROM ANY DAMAGE THROUGHOUT THE CONSTRUCTION PROCESS. NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION 05/08/2025 05/08/2025 3 0 7 8 7 ● s a x e T , n i t s u A ● e c r i l l C e e n w o r B 5 0 7 N W R B I E C N E D S E R T N U - 4 W E N I ADJ PROPERTY SF-3 702 Brownlee Circle EXAMPLE: 20 IN. DIAMETER TREE 1/4 CRZ 5'-0" 1/2 CRZ 10'-0" FULL CRZ 20'-0" 1220 Lavaca Street Austin, TX, 78701 WebberStudio.com 1/4 CRZ - NO IMPACT 1/2 CRZ - NO CUT/FILL > 4" FULL CRZ - PRESERVE 50% CITY CODE REQUIRES THAT PROPOSED DEVELOPMENTS DEMONSTRATE THAT TREES ARE PRESERVED TO THE MAXIMUM EXTENT REASONABLE AND FEASIBLE. TREE PRESERVATION IS EFFECTIVELY DEFINED AS ROOT SYSTEM PRESERVATION; A CRITICAL ROOT ZONE AREA (CRZ) IS ASSIGNED TO EACH TREE, BASED ON TRUNK DIAMETER SIZE. A MINIMUM OF 50% OF THE CRZ IS REQUIRED TO BE LEFT UNDISTURBED TO ACHIEVE MINIMAL CONFORMANCE WITH THE REGULATIONS. LEGAL DESCRIPTION PROJECT ADDRESS: 705 Brownlee Circle Austin Texas 78703 U.S.A. LEGAL DESCRIPTION: LOT 32 OF PARK VIEW, VOLUME 5, PAGE 69, PLAT RECORDS, TRAVIS CO.,TX DESCRIPTION OF WORK: DEMOLITION OF EXISTING DUPLEX AND CONSTRUCTION OF NEW 4-UNIT RESIDENCE OWNER'S NAME: BRAD HOSKINS & MELISSA SKIDMORE TREE LIST 872 875 879 N01 N02 N03 N04 N05 N06 N07 N08 N09 N10 N11 16.5" LIVE OAK 18" MESQUITE 25" PECAN TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD CURRENT ISSUE CDPROC50 14 May 2025 REVISIONS MARK DATE ISSUE 05.13.25 CDPROC49 PERMIT SP102 ARCHITECTURAL SITE PLAN 20 OF 117 COPYRIGHT © 2025 WEBBER+STUDIO ARCHITECTS A1 A2 A C1 B C D D1 D2 E F J K M P 6 3 : 1 | 5 2 0 2 , 4 1 y a M , y a d s e n d e W | # # # # . r e V | " 8 / 7 0 - ' 7 2 " 8 - ' 2 " 9 - ' 6 " 1 1 - ' 1 " 8 - ' 6 " 4 - ' 1 " 8 - ' 4 " 4 / 3 3 0 3 0 5 2 _ N W R B / T O D U T S / 7 2 d a c h c r A I i r o f i c s a B d u o c M B - I l l a c o l . 7 2 d u o c M B I l : l d u o c M B I SILT FENCE DETAIL & NOTES NO SCALE " 6 . I N M 6" MIN. W O L F TRENCH (BACKFILLED) FABRIC TOE-IN GEOTEXTILE FABRIC STL, FENCE POSTS MAX. 6' SPACING WOVEN WIRE SUPPORT 12 GA. WIRE NET BACKING NEW PARKING DECK W/MEP BELOW NEW UNDERGROUND WATER STORAGE TANK TRENCH CROSS SECTION SILT FENCE GENERAL NOTES: 1. STEEL POSTS WHICH SUPPORT THE SILT FENCE SHALL BE INSTALLED AT A SLIGHT ANGLE TOWARD THE ANTICIPATED RUNOFF SOURCE. POST MUST BE EMBEDDED A MINIMUM OF ONE FOOT. 2. THE TOE OF THE SILT FENCE SHALL BE TRENCHED IN WITH A SPADE OR MECHANICAL TRENCHER, SO THAT THE DOWNSLOPE FACE IS FLAT AND PERPENDICULAR TO THE LINE OF THE FLOW. WHERE FENCE CAN NOT BE TRENCHED IN (E.G. PAVEMENT) WEIGHT FABRIC FLAP WITH WASHED GRAVEL ON UPHILL SIDE TO PREVENT FLOW UNDER FENCE. 3. THE TRENCH MUST BE A MINIMUM OF 6 INCHES DEEP DEEP AND SIX INCHES WIDE TO ALLOW FOR THE SILT FENCE FABRIC TO BE LAID IN THE GROUND AND BACKFILLED WITH COMPACTED MATERIAL. 4. SILT FENCE SHOULD BE SECURELY FASTENED TO EACH STEEL SUPPORT POST OR TO WOVEN WIRE, WHICH IS IN TURN ATTACHED TO THE STEEL FENCE POST. 5. INSPECTION SHALL BE MADE WEEKLY OR AFTER EACH RAINFALL EVENT AND REPAIR OR REPLACEMENT SHALL BE MADE PROMPTLY AS NEEDED. 6. SILT FENCE SHALL BE REMOVED WHEN THE SITE IS COMPLETELY STABILIZED SO AS TO NOT BLOCK OR IMPEDED STORM FLOW OR DRAINAGE. 7. ACCUMULATED SILT SHALL BE REMOVED WHEN IT REACHES A DEPTH OF SIX INCHES. THE SILT SHALL BE DISPOSED OF IN AN APPROVED SITE AND IN SUCH A MANNER AS NOT TO CONTRIBUTE TO ADDITIONAL SILTATION. SILT FENCE & EROSION CONTROLS U P M P 6 3 : 1 | 5 2 0 2 , 4 1 y a M , y a d s e n d e W | # # # # . r e V | 3 0 3 0 5 2 _ N W R B / T O D U T S / 7 2 d a c h c r A I i r o f i c s a B d u o c M B - I l l a c o l . 7 2 d u o c M B I l : l d u o c M B I PP EXISTING DRIVEWAY TO REMAIN DURING CONSTRUCTION TO SERVE AS MATERIAL STORAGE SPOILS/DEBRIS PLACEMENT NEW PERVIOUS CONCRETE PAVING ASSEMBLY P U UP DN DN DR R R RG RG W D R D MATERIAL STORAGE MATERIAL STORAGE MATERIAL STORAGE PLYWOOD DEBRIS BOX N01 PP EXISTING CO CO NEW TYPE 1 DRIVEWAY PER DETAIL COA STANDARD NO. 433S-1 NEW SIDEWALK PAVERS PER CITY OF AUSTIN STANDARS NO. 480S-5 REMOVE EXISTING REMOVE EXISTING WATER METERS & WATER METERS & INSTALL NEW INSTALL NEW SERVICE & METERS SERVICE & METERS . I . C " 6 W W W CONC. & PAINT WASH OUT PORTA POTTY . I . C " 2 D N 879 INDICATES 1/4 CRZ 875 TREE PROTECTION FENCE (TYP.) - 5" CHAIN LINK MESH W/ 6" LAYER MULCH OVER 1/2 CRZ E E E E E G G INDICATES 1/4 CRZ 872 EXISTING GAS LINE CO REMOVE EXISTING ELECTRIC METERS REMOVE EXISTING OVERHEAD ELECTRICAL SERVICE NEW UNDERGROUND ELECTRICAL SERVICE TREE PROTECTION FENCE (TYP.) - 5" CHAIN LINK MESH W/ 6" LAYER MULCH OVER 1/2 CRZ REMOVE (2) EXISTING GAS METERS, INSTALL (1) NEW NOTE: LEVEL 1 FINISH FLOOR ELEVATION: +516.58' = +516'-7" = +100'-0" PLOT PLAN SCALE: 1/8" = 1'-0" 1 N SITE / LOT PLAN LEGEND PROPERTY LINE SET BACK LINE TREE (C.R.Z) CANOPY LINE OVERHEAD UTILITY LINE GAS LINE WATER LINE ELECTRIC LINE WOOD BOARD FENCE CHAIN LINK FENCE WIRE AND WOOD FENCE GAS METER ELECTRIC METER WATER METERS; (2) IN BOX CLEAN OUT AIR CONDITIONER POWER POLE WATER VALVE IRRIGATION CONTROL VALVE FIRE HYDRANT G E W CO PP WV PP Y D H TREE PROTECTION NOTES 12 GA. WIRE (OR STRAPS) STAPLED TO 2X6s. THIS METHOD PROTECTS TRUNK FROM DAMAGE BY CONSTRUCTION EQUIPMENT. IT DOES NOT PROTECT ROOTS FROM COMPACTION. BARRIER SHOULD EXTEND THE FULL DIAMETER OF THE TREE CROWN TREE TRUNK PROTECTION GALV'D CHAIN LINK FENCE MATERIAL SUPPORTED BY GALV'D MTL FENCE POSTS OR EQUIVALENT CONSTRUCTION FENCE. THIS METHOD PROTECTS TREE FROM ROOT COMPACTION FROM CONSTRUCTION EQUIPMENT. " 0 - ' 6 D E D N E M M O C E R TREE PROTECTION BARRIER IT IS THE ARCHITECT'S AND OWNER'S INTENT TO PROTECT ALL TREES IN PROXIMITY TO CONSTRUCTION AREA FROM DAMAGE OR INJURY DUE TO CONSTRUCTION. THE SUGGESTIONS FOR TREE PROTECTION PROVIDED ABOVE ARE EXPLICITLY NOT GUARANTEED TO FULLY PROTECT THE TREES. IT IS HIGHLY RECOMMENDED THAT A TREE SPECIALIST BE HIRED AND THAT SUCH COST BE REVIEWED WITH OWNER FOR APPROVAL PRIOR TO PROCUREMENT OF TREE SPECIALIST SERVICES. IF CONTRACTOR DOES NOT REVIEW WITH OWNER HIS OR HER WILLINGNESS OR NON- WILLINGNESS TO HIRE SUCH SPECIALIST, THEN IT WILL BE CONSTRUED AS CONTRACTOR'S WILLINGNESS TO ACCEPT LIABILITY FOR PROTECTING THE TREES FROM ANY DAMAGE THROUGHOUT THE CONSTRUCTION PROCESS. NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION 05/08/2025 3 0 7 8 7 ● s a x e T , n i t s u A ● e c r i l l C e e n w o r B 5 0 7 N W R B I E C N E D S E R T N U - 4 W E N I EXAMPLE: 20 IN. DIAMETER TREE 1/4 CRZ 5'-0" 1/2 CRZ 10'-0" FULL CRZ 20'-0" 1220 Lavaca Street Austin, TX, 78701 WebberStudio.com 1/4 CRZ - NO IMPACT 1/2 CRZ - NO CUT/FILL > 4" FULL CRZ - PRESERVE 50% CITY CODE REQUIRES THAT PROPOSED DEVELOPMENTS DEMONSTRATE THAT TREES ARE PRESERVED TO THE MAXIMUM EXTENT REASONABLE AND FEASIBLE. TREE PRESERVATION IS EFFECTIVELY DEFINED AS ROOT SYSTEM PRESERVATION; A CRITICAL ROOT ZONE AREA (CRZ) IS ASSIGNED TO EACH TREE, BASED ON TRUNK DIAMETER SIZE. A MINIMUM OF 50% OF THE CRZ IS REQUIRED TO BE LEFT UNDISTURBED TO ACHIEVE MINIMAL CONFORMANCE WITH THE REGULATIONS. LEGAL DESCRIPTION PROJECT ADDRESS: 705 Brownlee Circle Austin Texas 78703 U.S.A. LEGAL DESCRIPTION: LOT 32 OF PARK VIEW, VOLUME 5, PAGE 69, PLAT RECORDS, TRAVIS CO.,TX DESCRIPTION OF WORK: DEMOLITION OF EXISTING DUPLEX AND CONSTRUCTION OF NEW 4-UNIT RESIDENCE OWNER'S NAME: BRAD HOSKINS & MELISSA SKIDMORE TREE LIST 872 875 879 N01 N02 N03 N04 N05 N06 N07 N08 N09 N10 N11 16.5" LIVE OAK 18" MESQUITE 25" PECAN TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD CURRENT ISSUE CDPROC50 14 May 2025 REVISIONS MARK DATE ISSUE 05.13.25 CDPROC49 PERMIT SP103 PLOT PLAN 21 OF 117 COPYRIGHT © 2025 WEBBER+STUDIO ARCHITECTS 509 1/A312 0 1 3 A / 1 510 1/A311 8 0 3 A / 1 511 7 0 3 A / 1 1/A201 6 0 3 A / 2 1 0 3 A / 1 6 0 3 A / 1 FIRE RATED ASSEMBLIES 1-HOUR RATED ASSEMBLY 2-HOUR RATED ASSEMBLY GARAGE CEILING ASSEMBLY 0 0 8 4/A SETBACK LINE D N 1 4 1 3 1 2 STAIR D STAIR D 1 1 1 0 9 8 7 6 5 4 T.O.WATER @ 89'-6" POOL 4'-0" DEEP B.O. POOL @ 85'-6" 3 2 U P 1 F.F.E POOL DECK 90'-0" B A N B E N Q U E T C H 1/A 2 0 2 OUTLINE OF BUILDING ABOVE WA04A EQUIPMENT C001 --- C001.1 STORAGE C002 CONC-1 C002.1 STORAGE CLOSET C004 WD-3 C004.1 HALL C003 WD-3 UNIT C F.F.E BASEMENT 90'-0" 4/A410 C005.3 2 - G / G - 6 W ELEV. - A P ELEV. 2 - G / G - 6 W - A P WA-W6-M/G-0 C003.1 B A N B E N Q U E T C H /G-0 M 6- W A- W BBQ/OUTDOOR KITCHEN F.F.E DECK PAVERS 90'-0" C003.2 4 3 2 5/A 4 1 1 0 0 2 A / 2 3/A202 UNIT D DECK 0 2/A202 OUTLINE OF UNIT C DECK 1 ABOVE BBQ AREA D001.1 8/A411 UNIT D POOL DEN D001 WD-3 UNIT D F.F.E BASEMENT 90'-0" KITCHENETTE 7/A411 1 1 4 A / 6 MURPHY BED 5 6 7 1 - S 6 W - A P UP 1 12 11 8 9 10 STAIR C 27 R @ 9" 26 T @ VARIES ANGLE 30° 0 A603 3/A603 512 513 514 MECH CLOSET C005 WD-3 C005.1 1 2 P U OUTLINE OF EXISTING FOUNDATION ABOVE 3 4 5 6 7 8 9 10 11 12 13 14 15 16 DN UNIT B SLAB ABOVE SHELF ABOVE BAR C006.1 4/A411 SECRET ROOM C006 WD-3 1 1 4 A 3 / 1 1 4 A / 1 2/A411 PA-W6S-1 D001.1 D001.2 D001.3 OUTLINE OF UNIT C DECK 1 ABOVE LINEN D003.1 2 1 4 A / 4 2/A412 BATH D003 C006.1 2 1 4 A / 3 1/A412 E V O B A 1 K C E D C T I N U F O E N L T U O I 2/A800 UNIT A SLAB ABOVE OUTLINE EXISTING FOUNDATION ABOVE NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION 05/08/2025 3/A 8 0 0 515 516 1/A305 2/G104 1/A304 N W R B I E C N E D S E R T N U - 4 W E N I 3 0 7 8 7 ● s a x e T , n i t s u A ● e c r i l l C e e n w o r B 5 0 7 1/A303 0 0 8 A / 1 1/A302 1220 Lavaca Street Austin, TX, 78701 WebberStudio.com 0 0 2 A / 1 1/A313 3 1 4 A / 7 CURRENT ISSUE CDPROC50 14 May 2025 REVISIONS MARK DATE ISSUE 1/G104 05.13.25 CDPROC49 PERMIT 1/A300 516 517 518 0 1 3 A 1 / 8 0 3 A 1 / 7 0 3 A 1 / 2/A201 6 0 3 A 2 / 1 0 3 A 1 / 6 0 3 A 1 / NOTE: LEVEL 1 FINISH FLOOR ELEVATION: +516.58' = +516'-7" = +100'-0" FINISH AND MARKER PLAN: BASEMENT PLAN SCALE: 1/4" = 1'-0" 1 A100 FINISH AND MARKER PLAN : BASEMENT 22 OF 117 COPYRIGHT © 2025 WEBBER+STUDIO ARCHITECTS N 1/A305 1/A304 1/A313 1/A303 1/A302 1/A300 M P 6 3 : 1 | 5 2 0 2 , 4 1 y a M , y a d s e n d e W | # # # # . r e V | 3 0 3 0 5 2 _ N W R B / T O D U T S / 7 2 d a c h c r A I i r o f i c s a B d u o c M B - I l l a c o l . 513 514 515 1/A311 7 2 d u o c M B I l : l d u o c M B I RAIL-1 1/A312 0 1 3 A / 1 1/A311 8 0 3 A / 1 7 0 3 A / 1 1/A201 6 0 3 A / 2 1 0 3 A / 1 6 0 3 A / 1 FIRE RATED ASSEMBLIES 1-HOUR RATED ASSEMBLY 2-HOUR RATED ASSEMBLY GARAGE CEILING ASSEMBLY 0 0 8 4/A 4'-0" 15'-8 1/4" 14'-11 5/8" 12'-0" STAIR D 5 7/8" 8 5/8" 5 4 3 2 U P 1 OUTLINE OF BUILDING ABOVE UILDING ABOVE OUTLINE OF B WA-W6-P/G-0 WA-W6-P/G-0 WA-W6-P/G-0 C100.1 3/A 8 0 0 D N 1 4 1 WA-W6-P/G-0 3 STAIR D 1 2 1 1 1 0 9 WA-W6-R/G-0 8 7 6 100'-0" 8/A401 WA-W6-R/G-0 7/A 4 0 1 POOL BAJA SHELF 0 0 2 A / 2 WA-W6-R/G-0 2/A202 LOWER TERRACE F.F.E LOWER DECK 90'-0" C100.1 1 2 2 . 0 0 1 C B104.1 WA-W6-M/G-0 B105.1 WA-W6-M/M-0 C101.1 PARKING #4 PARKING #3 9/A401 UNIT C GARAGE C101 CONC-1 " 2 / 1 2 E P O L S B A L S C N O C . . E F F . " 0 - ' 0 0 1 1 0 4 A / 5 I E S R " 8 = T F / " 1 " 0 - ' 8 F.F.E. CONC SLAB 99'-4" 6/A401 FPSC C100.3 1 - G / G - 6 W - A P 2 - G / G - 6 W - A P UP 1 - G / G - 6 W - A P UNIT C 1 0 4 A / 3 4/A410 C100.4 ELEV. ELEV. 17 18 7 16 15 14 STAIR C 8 9 10 13 12 11 P U 1 0 4 A / 1 4/A401 LOBBY C100 WD-3 2/A401 DN 2 - G / G - 6 W - A P 18 17 16 15 14 1 2 3 4 5 6 7 8 9 10 11 12 13 UP I A R A T S 3 4 5 6 7 8 9 10 11 12 13 14 15 16 16 DN DN WA-W6-R/G-1 STAIR C 3/A603 F.E.E DECK 100'-0" BEDROOM B104 WD-3 P A - W 6 - S / S - 1 BATH B105 C006.1 B105.1 PA-W4-S/S-1 B104.1 P A - W 4 - S / S - 1 PA-W4-S/S-1 CLOSET B103 WD-3 B103.1 DR R RG 2/A414 PA-W6S-1 0 - G / M - 6 W - A W B101.1 UNIT B 100'-0" 4/A414 4 1 4 A / 3 BATH A106 B106.1 LIVING B101 WD-3 0 - G / M - 6 W - A W 1 . 1 0 1 B 0 - G / M - 6 W - A W O U T L I N E B U I L D I N G A B O V E A101.1 WA-W6-M/G-0 C100.2 C100.3 KITCHEN B102 WD-3 B102.1 4 1 4 A / 1 3 0 7 8 7 ● s a x e T , n i t s u A ● e c r i l l C e e n w o r B 5 0 7 PARKING #2 PARKING #1 1/A305 2/G104 1/A304 N W R B I E C N E D S E R T N U - 4 W E N I RAIL-1 36" HIGH GUARDRAIL UNIT C DECK 1 DECK-1 5 7/8" 9'-0 1/4" 879 OUTLINE BASEMENT BELOW UNIT C DECK 1 4/A202 875 RAIL-1 PLANTER 0 - G / M - 6 W - A W R RG APPL 106.2 2 1 4 A / 4 TERRACE B. A102.1 KITCHEN A102 WD-3 W D 3 1 4 A / 1 2/A413 LIVING A101 WD-3 4/A413 3 1 4 A / 3 W A - W 6 - M / G - 0 UNIT A 100'-0" A101.1 BATH A103 A104.2 BEDROOM A104 WD-3 A104.1 0 - G / M - 6 W - A W PA-W4-S/S-1 PA-W4-S/S-1 A104.3 A112.1 LAUNDRY A111 R D CLOSET A110 A111.1 A109.1 A106.1 PA-W6-S/S-1 BATH A105 C006.1 1 - S / S - 6 W - A P A107.1 BATH A107 C006.1 0 - G / F - 6 W - A W SPKLR A106 A111.1 P A - W 6 - S / S - 1 BEDROOM 3 1 4 A / 7 A109 WD-3 3 1 4 A / 5 PA-W6-G/G-1 WA-W6-M/G-1 18 17 16 A108.1 CLOSET A108 WD-3 5 1 4 1 3 1 2 1 1 1 W A - W 6 - I / G - 1 0 1 0 0 2 A / 1 1/A313 1 . 9 0 1 A 0 - G / M - 6 W - A W 123456789 1/A300 UP 1/G104 2/A800 A104.1 WA-W6-M/G-1 A106.1 A107.1 WA-W6-M/G-1 STAIR B WA-W6-M/M-0 0 1 3 A 1 / 8 0 3 A 1 / 7 0 3 A 1 / 2/A201 6 0 3 A 2 / 1 0 3 A 1 / 6 0 3 A 1 / NOTE: LEVEL 1 FINISH FLOOR ELEVATION: +516.58' = +516'-7" = +100'-0" FINISH AND MARKER PLAN: 1st Floor SCALE: 1/4" = 1'-0" 1 NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION 05/08/2025 N01 1/A303 0 0 8 A / 1 1/A302 1220 Lavaca Street Austin, TX, 78701 WebberStudio.com CURRENT ISSUE CDPROC50 14 May 2025 REVISIONS MARK DATE ISSUE 05.13.25 CDPROC49 PERMIT A101 FINISH AND MARKER PLAN : 1st LEVEL 23 OF 117 COPYRIGHT © 2025 WEBBER+STUDIO ARCHITECTS N 1/A305 1/A304 1/A313 1/A303 1/A302 1/A300 1/A311 M P 6 3 : 1 | 5 2 0 2 , 4 1 y a M , y a d s e n d e W | # # # # . r e V | 3 0 3 0 5 2 _ N W R B / T O D U T S / 7 2 d a c h c r A I i r o f i c s a B d u o c M B - I l l a c o l . 7 2 d u o c M B I l : l d u o c M B I TALL CAB W A - W 6 - R / G - 0 1/A305 FIRE RATED ASSEMBLIES 1-HOUR RATED ASSEMBLY 2-HOUR RATED ASSEMBLY GARAGE CEILING ASSEMBLY NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION 05/08/2025 3/A 8 0 0 3 0 7 8 7 ● s a x e T , n i t s u A ● e c r i l l C e e n w o r B 5 0 7 2/G104 1/A304 N W R B I E C N E D S E R T N U - 4 W E N I 1/A303 0 0 8 A / 1 1/A302 1220 Lavaca Street Austin, TX, 78701 WebberStudio.com 1/A312 0 1 3 A / 1 1/A311 8 0 3 A / 1 7 0 3 A / 1 1/A201 6 0 3 A / 2 1 0 3 A / 1 6 0 3 A / 1 0 0 8 4/A WA-W6-R/G-0 7/A406 R 2'-6" 5 1/2" WA-W6-R/W-0 5'-8 3/4" C215.1 5 1/2" C209.1 8/A 4 0 6 PETER´S BATH C215 C215.1 6/A 4 0 6 9/A406 C215.1 3/A406 PETER´S ROOM C209 WD-3 2/A 4 0 6 C209.2 4/A406 1/A406 C209.1 1'-7 1/2" C211.1 7/A407 8/A 4 0 7 G R E E 6/A 4 0 7 N W A L L BATH C214 C214.1 5/A407 C214.1 R 1'-6" VESTIBULE I E N L R E T N E C D U T S G N I T S I X E L L A W 3 1/2" 5'-11 1/2" 5 1/2" WA-W6-R/W-0 C200.2 WA-W6-R/G-0 C208.1 CLOSET C210 WD-3 6 0 4 A / 5 R 1'-6" C208.1 STAIR A DN DN 21 20 " 5 - ' 19 2 18 17 16 15 14 18 13 17 12 16 I A R A T S 11 15 10 14 LANDING C200 WD-3 4/A410 C200.1 ELEV. WA-W6-R/G-0 8 8/A408 PR 0 4 A / 7 C208 8 0 4 A / 5 R 1'-6" 6/A408 PANTRY FRZ REF CH HERB GARDEN C201.1 UP 1 2 3 4 5 6 11 7 12 8 13 R 1'-6" BAR 1/A402 KITCHEN C201 WD-3 MW T/R 2/A402 3/A402 DW ISLAND I I O U T L N E B U L D N G B E L O W I 4/A 4 0 7 C 2 1 3.1 WA-W6-R/W-0 3/A407 BEDROOM C213 WD-3 9/A 4 0 7 0 0 2 A / 2 2/A202 2 3/4" 9'-0 1/4" 2 1'-2" 1 1'-1 1" 1/A305 1/A304 1/A313 1/A303 1/A302 1/A300 1/A311 M P 6 3 : 1 | 5 2 0 2 , 4 1 y a M , y a d s e n d e W | # # # # . r e V | 3 0 3 0 5 2 _ N W R B / T O D U T S / 7 2 d a c h c r A I i r o f i c s a B d u o c M B - I l l a c o l . 7 2 d u o c M B I l : l d u o c M B I 1/A407 C212 .1 R 0'-8" 4/A408 3/A408 M CLOSET C212 2/A408 C212 .2 8 0 4 A / 1 27 R @ 9" 26 T @ VARIES ANGLE 30° 27 26 DN 30° 25 24 W / D 19 STAIR C 20 21 23 22 9 1 - G / R - 6 W - A W C200.3 C203.3 3'-4" WA-W6-R/G-1 STAIR C 2 A603 3/A603 2 1 4 A / 4 COLS. UP COL. DOWN 3 0 4 A / 1 R 1'-6" 4 0 4 A 1 / 2/A403 UNIT C 30 X 22" MIN. CLR. ATTIC SCUTTLE LADDER TO MECH ATTIC LIVING ROOM C206 WD-3 OUTLINE ATTIC ABOVE 206.1 UNIT C DECK 2 UNIT C DECK 2 C207 DECK-2 DINING C202 WD-3 L 2 / A 4 0 4 BOOKCASE C203.1 C 2 0 3 . 1 C204.1 KITCHENETTE C204 8/A405 WD-3 C205.1 5 5 0 0 4 4 A A / / 7 5 6/A405 OFFICE BATH C205 TILE 205.1 E S A C K O O B 5 0 4 A 3 / DN 18 17 16 4/A405 OFFICE / ADU C203 WD-3 5 0 4 A / 1 2/A405 C203.2 3 1 4 A / 7 UNIT C DECK 2 C206 DECK-2 STAIR B OUTLINE OF WALL BELOW 0 0 2 A / 1 WA-W6-R/G-0 COLS. DOWN W A - W 6 - R / G - 0 1/A313 UP 1/G104 5 1 4 1 3 1 2 1 1 1 0 1 123456789 1/A300 2/A800 STAIR B WA-W6-M/M-0 0 1 3 A 1 / 8 0 3 A 1 / 7 0 3 A 1 / 2/A201 6 0 3 A 2 / 1 0 3 A 1 / 6 0 3 A 1 / NOTE: LEVEL 1 FINISH FLOOR ELEVATION: +516.58' = +516'-7" = +100'-0" FINISH AND MARKER PLAN: 2nd Floor SCALE: 1/4" = 1'-0" 1 CURRENT ISSUE CDPROC50 14 May 2025 REVISIONS MARK DATE ISSUE 05.13.25 CDPROC49 PERMIT A102 FINISH AND MARKER PLAN : 2nd LEVEL 24 OF 117 COPYRIGHT © 2025 WEBBER+STUDIO ARCHITECTS N 1/A312 0 1 3 A / 1 1/A311 8 0 3 A / 1 7 0 3 A / 1 1/A201 6 0 3 A / 2 1 0 3 A / 1 6 0 3 A / 1 0 0 8 4/A WA-W6-R/W-0 L L A W D U T S G N I T S I X E E N L R E T N E C I L L A W D U T S G N I T S I X E E N L R E T N E C I 3/A 8 0 0 PLANTER 9 0 4 A / 1 0 - G / R - 6 W - A W 2 - G / R - 6 W - A W C200.1 OPEN 3/A410 C302.1 STORAGE C302 WD-3 0 1 4 A / 2 C C301.1 PENTHOUSE C301 WD-3 4/A410 C301.2 ELEV. ELEV. VOID DN STAIR A 21 20 19 18 17 16 15 14 13 12 11 10 9 8 UP 1 2 3 4 5 6 7 8 C200.3 OPEN 2 1 4 A / 4 0 - G / R - 6 W - A W DRIP-1 WA-W6-R/G-0 3 1 4 A / 7 5/A409 UNIT C ROOF DECK C303 WD-3 4/A409 UNIT C ROOF DECK 2/A 4 0 9 3/A409 2/A800 FIRE RATED ASSEMBLIES 1-HOUR RATED ASSEMBLY 2-HOUR RATED ASSEMBLY GARAGE CEILING ASSEMBLY NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION 05/08/2025 3 0 7 8 7 ● s a x e T , n i t s u A ● e c r i l l C e e n w o r B 5 0 7 1/A305 2/G104 1/A304 N W R B LINE OF MECHANICAL PENTHOUSE BELOW I E C N E D S E R T N U - 4 W E N I 1/A303 0 0 8 A / 1 1/A302 1220 Lavaca Street Austin, TX, 78701 WebberStudio.com 0 0 2 A / 1 1/A313 CURRENT ISSUE CDPROC50 14 May 2025 REVISIONS MARK DATE ISSUE 1/G104 05.13.25 CDPROC49 PERMIT 1/A300 6'-0" 8'-2 1/4" 24'-0 5/8" 11'-9 5/8" 2'-10 1/4" 2'-0" 0 1 3 A 1 / 8 0 3 A 1 / 7 0 3 A 1 / 2/A201 6 0 3 A 2 / 1 0 3 A 1 / 6 0 3 A 1 / NOTE: LEVEL 1 FINISH FLOOR ELEVATION: +516.58' = +516'-7" = +100'-0" A103 FINISH AND MARKER PLAN : PH & ROOF DECK 25 OF 117 FINISH AND MARKER PLAN: 3rd Floor SCALE: 1/4" = 1'-0" 1 COPYRIGHT © 2025 WEBBER+STUDIO ARCHITECTS N WA-W6-R/W-0 POOL 0 0 2 A / 2 2/A202 1/A305 1/A304 1/A313 1/A303 1/A302 1/A300 1/A311 M P 6 3 : 1 | 5 2 0 2 , 4 1 y a M , y a d s e n d e W | # # # # . r e V | 3 0 3 0 5 2 _ N W R B / T O D U T S / 7 2 d a c h c r A I i r o f i c s a B d u o c M B - I l l a c o l . 7 2 d u o c M B I l : l d u o c M B I A SETBACK LINE D N A1 4'-0" A2 C1 U P 1 F.F.E POOL DECK 90'-0" STAIR D STAIR D 14 R @7 23/32" 13 T @16" 5 6 4 3 2 T.O.WATER @ 89'-6" POOL 4'-0" DEEP B.O. POOL @ 85'-6" 10' REAR YARD SETBACK 1 1.75 B C D D1 D2 E F I J K M P 6 3 : 1 | 5 2 0 2 , 4 1 y a M , y a d s e n d e W | # # # # . r e V | 3 0 3 0 5 2 _ N W R B / T O D U T S / 7 2 d a c h c r A I i r o f i c s a B d u o c M B - I l l a c o l . 513 514 515 7 2 d u o c M B I l : l d u o c M B I 509 510 2 2.4 3 3 4 5 6 7 1 1.5 1.75 5'-0" INTERIOR SIDE YARD SETBACK 511 512 (S11°17'00"W) (108.26') N06°46'19"E 108.36' 513 FIRE RATED ASSEMBLIES 1-HOUR RATED ASSEMBLY 2-HOUR RATED ASSEMBLY GARAGE CEILING ASSEMBLY SMOKE DETECTOR LEGEND S SMOKE DETECTOR TO BE HARDWIRED AND INTERCONNECTED PER CODE SCO SMOKE DETECTOR TO BE HARDWIRED AND INTERCONNECTED PER CODE @CEILING CO CO ALARM NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION 05/08/2025 514 L L A W D U T S G N I T S I X E E N L R E T N E C I 515 L L A W D U T S G N I T S I X E E N L R E T N E C I L L A W D U T S G N I T S I X E E N L R E T N E C I 1/A602 1/A601 L L A W D U T S G N I T S I X E E N L R E T N E C I MECH CLOSET C005 C005.1 1 2 P U OUTLINE OF BUILDING ABOVE WA04A EQUIPMENT C001 STORAGE C002 C001.1 S B A N B E N Q U E T C H STORAGE CLOSET C004 C004.1 UNIT C F.F.E BASEMENT 90'-0" HALL C003 3/A604 C005.3 2 - G / G - 6 W ELEV. - A P ELEV. 2 - G / G - 6 W - A P SCO C003.1 S C002.1 2 / A 6 0 4 WA-W6-M/G-0 B A N B E N Q U E T C H C003.2 4 3 2 /G-0 M 6- W A- W BBQ/OUTDOOR KITCHEN D002 DECK-3 F.F.E DECK PAVERS 90'-0" UNIT D DECK 0 UNIT D BBQ AREA D001.1 D001 WD-3 POOL DEN D001 UNIT D F.F.E BASEMENT 90'-0" KITCHENETTE MURPHY BED 5 6 7 1 - S 6 W - A P UP 1 12 11 8 9 10 STAIR C 27 R @ 9" 26 T @ VARIES ANGLE 30° 3/A603 OUTLINE OF EXISTING FOUNDATION ABOVE UNIT B SLAB ABOVE SHELF ABOVE BAR " 2 / 1 7 @ R 6 1 " 1 1 @ T 5 1 I A R A T S 3 4 5 6 7 8 9 10 SCO C006.1 S 4 0 6 A / 2 DN SECRET ROOM C006 1/A602 1/A601 A2 PA-W6S-1 LINEN D003.1 C1 BATH D003 D001.1 D001.2 D001.3 OUTLINE OF UNIT C DECK 1 ABOVE E V O B A 1 K C E D C T I N U F O E N L T U O I UNIT A SLAB ABOVE I OUTLINE EXISTING FOUNDATION ABOVE B C D D1 A D2 E F G H J K 2/G104 K C A B T E S D R A Y T N O R F ' 5 2 1/G104 3 0 7 8 7 ● s a x e T , n i t s u A ● e c r i l l C e e n w o r B 5 0 7 516 " 0 6'- 1 N W R B I E C N E D S E R T N U - 4 W E N I 1220 Lavaca Street Austin, TX, 78701 WebberStudio.com CURRENT ISSUE CDPROC50 14 May 2025 REVISIONS MARK DATE ISSUE 05.13.25 CDPROC49 PERMIT A110 DIMENSION FLOOR PLAN : BASEMENT 26 OF 117 COPYRIGHT © 2025 WEBBER+STUDIO ARCHITECTS N 516 PROPERTY LINE 517 2.4 (S07°26'00"E) (163.54') S11°46'56"E 163.80" 3 3 2 518 4 5 6 7 NOTE: LEVEL 1 FINISH FLOOR ELEVATION: +516.58' = +516'-7" = +100'-0" DIMENSION FLOOR PLAN : BASEMENT SCALE: 1/4" = 1'-0" 1 15'-8 1/4" 14'-11 5/8" 12'-0" STAIR D C1 5 7/8" 8 5/8" 1 0 9 WA-W6-R/G-0 8 7 14 R @7 23/32" 13 T @16" 6 5 4 100'-0" 3 2 U P 1 WA-W6-R/G-0 POOL BAJA SHELF WA-W6-R/G-0 LOWER TERRACE F.F.E LOWER DECK 90'-0" 2'-8 1/4" RAIL-1 36" HIGH GUARDRAIL 5 7/8" 1 9'-0 1/4" 2 1'-1 3/4" 1.75 RAIL-1 23'-6 1/4" 10'-7 1/2" 2 2.4 3 3 76'-5" 6'-0" 8'-2 1/4" 24'-0 5/8" 4 37'-5 1/8" 12'-8" 5 1/2" 6'-9 3/4" 6'-10 3/8" 5'-0 3/4" 5/8" 5 1/2" 17'-5 1/4" 5 1/2" 5'-3 1/8" 1'-4 5/8" 5 1/2" 4'-3 5/8" 7'-1 7/8" 7 1/4" 5 1/2" 6'-8 3/8" 11'-9 5/8" 11'-2 3/8" 11'-4 1/8" 5 1/2" 5 6 7 2'-0" 2'-10 1/4" 2'-10 1/4" 2'-4 3/4" 5 1/2" 1 1.5 1.75 FIRE RATED ASSEMBLIES 1-HOUR RATED ASSEMBLY 2-HOUR RATED ASSEMBLY GARAGE CEILING ASSEMBLY SMOKE DETECTOR LEGEND S SMOKE DETECTOR TO BE HARDWIRED AND INTERCONNECTED PER CODE SCO SMOKE DETECTOR TO BE HARDWIRED AND INTERCONNECTED PER CODE @CEILING CO CO ALARM NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION 05/08/2025 A A1 4'-0" A2 OUTLINE OF BUILDING ABOVE UILDING ABOVE OUTLINE OF B WA-W6-P/G-0 WA-W6-P/G-0 WA-W6-P/G-0 C101.1 D N 1 4 1/A602 1/A601 C100.1 F.F.E +100'-0" 1 WA-W6-P/G-0 3 STAIR D 1 2 1 1 VA RIE S PARKING #4 PARKING #3 2 1 / 1 - ' 9 9 FPSC C100.3 C100.1 1 2 P U 2 . 0 0 1 C B104.1 WA-W6-M/G-0 B105.1 WA-W6-M/M-0 UNIT C GARAGE C101 " 2 / 1 2 E P O L S VARIES B A L S C N O C . . E F F . " 0 - ' 0 0 1 1 A604 1 - G / G - 6 W - A P UNIT C LOBBY C100 F.F.E LOBBY +100'-0" 3/A604 C100.4 " 4 - ' 9 9 F.F.E. CONC SLAB 99'-4" I E S R " 8 = T F / " 1 " 0 - ' 8 2 / A 6 0 4 2 - G / G - 6 W - A P UP 1 - G / G - 6 W - A P " 0 - ' 4 WA-W6-R/G-1 F.F.E DECK +100'-0" UNIT C DECK 1 DECK-1 ELEV. ELEV. 17 18 7 16 15 14 STAIR C 8 9 10 13 12 11 STAIR C 1 A603 3/A603 UP " 4 6 / 1 2 7 @ R 8 1 " 8 / 3 1 1 @ T 7 1 I A R A T S 1 2 3 4 5 6 7 8 9 10 3 4 5 6 7 8 9 10 11 12 13 14 15 BEDROOM B104 P A - W 6 - S / S - 1 BATH B105 0 - G / M - 6 W - A W S B105.1 PA-W4-S/S-1 B104.1 B103.1 P A - W 4 - S / S - 1 B101.1 UNIT B 100'-0" BATH A106 B106.1 PA-W4-S/S-1 SCO 16 16 DN DN DR CLOSET B103 CO DN 2 - G / G - 6 W - A P 4 0 6 A / 2 R KITCHEN B102 C100.2 C100.3 1/A602 1/A601 B102.1 A2 F.E.E DECK 100'-0" PLANTER 0 - G / M - 6 W - A W R RG RG S PA-W6S-1 LIVING B101 0 - G / M - 6 W - A W 1 . 1 0 1 B 0 - G / M - 6 W - A W OUTLINE BASEMENT BELOW " 1 - ' 3 UNIT C DECK 1 C1 TERRACE B. A102.1 KITCHEN A102 S W D LIVING A101 O U T L I N E B U I L D I N G A B O V E A101.1 WA-W6-M/G-0 W A - W 6 - M / G - 0 UNIT A 100'-0" A101.1 PA-W4-S/S-1 PA-W4-S/S-1 A11 I BATH A103 A104.2 A104.3 S SCO A112.1 LAUNDRY A111 R D CLOSET A110 A111.1 SCO A109.1 S RAIL-1 A104.1 0 - G / M - 6 W - A W BEDROOM A104 PA-W6-S/S-1 A106.1 BATH A105 1 - S / S - 6 W - A P A107.1 BATH A107 0 - G / F - 6 W - A W SPKLR A106 A111.1 P A - W 6 - S / S - 1 BEDROOM A109 PA-W6-G/G-1 WA-W6-M/G-1 A108.1 CLOSET A108 W A - W 6 - I / G - 1 18 R @7 21/64" 17 T @10" UP 1234567 1/G104 17'-6" 23'-4 1/4" 21'-3 3/8" 14'-8 7/8" 6'-0" 3'-1 3/4" 8'-7 1/8" 11'-2 1/4" 9'-7 3/4" 6'-10 1/4" 8'-2 1/4" 24'-0 5/8" 11'-9 5/8" 2'-10 1/4" 2'-0" A104.1 WA-W6-M/G-1 A106.1 A107.1 WA-W6-M/G-1 STAIR B WA-W6-M/M-0 2 2.4 3 3 4 5 6 7 PARKING #2 PARKING #1 " 8 - ' 2 " 9 - ' 6 " 1 1 - ' 1 " 8 - ' 6 " 4 - ' 1 " 8 - ' 4 " 1 1 - ' 4 2/G104 " 2 / 1 6 - ' 9 " 4 / 1 1 - ' 9 " 4 / 3 7 - ' 8 1 " 4 / 3 0 - ' 8 " 2 / 1 8 - ' 9 " 2 / 1 8 - ' 9 " 4 / 3 7 - ' 1 " 4 / 1 2 - ' 5 " 2 / 1 3 - ' 0 1 1 . 9 0 1 A 0 - G / M - 6 W - A W B C D D1 A D2 E F G H J K 3 0 7 8 7 ● s a x e T , n i t s u A ● e c r i l l C e e n w o r B 5 0 7 N W R B I E C N E D S E R T N U - 4 W E N I 1220 Lavaca Street Austin, TX, 78701 WebberStudio.com CURRENT ISSUE CDPROC50 14 May 2025 REVISIONS MARK DATE ISSUE 05.13.25 CDPROC49 PERMIT A111 DIMENSION FLOOR PLAN : 1st LEVEL NOTE: LEVEL 1 FINISH FLOOR ELEVATION: +516.58' = +516'-7" = +100'-0" DIMENSION FLOOR PLAN : 1st LEVEL SCALE: 1/4" = 1'-0" 1 27 OF 117 N COPYRIGHT © 2025 WEBBER+STUDIO ARCHITECTS " 8 - ' 2 " 9 - ' 6 " 1 1 - ' 1 " 8 - ' 6 " 4 - ' 1 " 8 - ' 4 " 4 / 3 9 - ' 9 1 " 2 / 1 3 - ' 0 1 B C D D1 D2 E F I J K M P 6 3 : 1 | 5 2 0 2 , 4 1 y a M , y a d s e n d e W | # # # # . r e V | 3 0 3 0 5 2 _ N W R B / T O D U T S / 7 2 d a c h c r A I i r o f i c s a B d u o c M B - I l l a c o l . 7 2 d u o c M B I l : l d u o c M B I 1 1.5 5 1/2" WA-W6-R/W-0 5'-8 3/4" C215.1 2 2.4 3 3 4 5 6 7 6'-0" 8'-2 1/4" 24'-0 5/8" 11'-9 5/8" 2'-10 1/4" 2'-0" 15'-1 7/8" 24'-8 3/8" 1.75 C209.2 5 1/2" C209.1 5'-5 5/8" 3 1/2" 4'-4 1/2" 9 1/4" 1'-6 3/4" 3 1/2" I E N L R E T N E C D U T S G N I T S I X E L L A W 3'-4 3/8" 1'-8 1/4" 60'-10 1/2" 9 1/4" 9 1/4" 4'-8 1/4" 6'-0" 3 1/2" 31'-3 1/4" 9'-0 3/4" FIRE RATED ASSEMBLIES 1-HOUR RATED ASSEMBLY 2-HOUR RATED ASSEMBLY GARAGE CEILING ASSEMBLY SMOKE DETECTOR LEGEND S SMOKE DETECTOR TO BE HARDWIRED AND INTERCONNECTED PER CODE SCO SMOKE DETECTOR TO BE HARDWIRED AND INTERCONNECTED PER CODE @CEILING CO CO ALARM NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION 05/08/2025 6'-2 1/2" 4'-0" A1 26'-5" 5 1/2" A2 WA-W6-R/G-0 PETER´S BATH C215 C215 TILE C215.1 R 2'-6" C213.10 A 7'-3 1/2" " 4 5'- 10'-2 1/4" 5 1/2" C213.9 C213.8 C215.1 PETER´S ROOM C209 3 1/2" 5'-11 1/2" 5 1/2" WA-W6-R/W-0 1/A602 1/A601 C200.2 WA-W6-R/G-0 C208.1 C209 WD-3 CLOSET C210 C210 WD-3 R 1'-6" C208.1 C208 PR WD-3 C208 WA-W6-R/G-0 C213.7 WA-W6-R/W-0 C213.6 C 2 1 3.5 G R E E N W A L L BATH C214 C214 TILE C214.1 BEDROOM C213 C213 WD-3 C214.1 R 1'-6" 4'-0" C 2 1 3.4 C 2 1 3.3 C 2 1 3.2 C 2 1 3.1 C209.1 S SCO 1'-7 1/2" LANDING C200 C200 WD-3 F.F.E 2ND LEVEL 111'-0" STAIR A 3/A604 C200.1 ELEV. C211.1 S VESTIBULE C211 WD-3 2 / A 6 0 .1 4 DN " 5 - ' 2 DN 18 17 16 15 I A R A T S 14 4 0 6 A / 2 CH UP " 8 / 3 " 4 6 / 1 2 " 7 8 @ / 5 R 7 @ 8 1 R 1 2 1 " 1 8 @ / 3 T 1 1 7 @ 1 T 0 2 1 2 3 4 5 11 12 13 R 0'-8" M CLOSET C212 C212 WD-3 .2 27 R @ 9" 26 T @ VARIES ANGLE 30° 27 26 DN 30° 25 24 W / D 19 STAIR C 20 21 23 22 1 - G / R - 6 W - A W C200.3 C203.3 1/A602 1/A601 R 1'-6" PANTRY FRZ REF HERB GARDEN C201.1 KITCHEN C201 C201 WD-3 S MW T/R DW ISLAND R 1'-6" BAR 1 1'-1 1" 3'-4" A2 R 1'-6" WA-W6-R/G-1 STAIR C 3/A603 C1 COLS. UP COL. DOWN RAIL-2 UNIT C C202 WD-3 30 X 22" MIN. CLR. ATTIC SCUTTLE LADDER TO MECH ATTIC LIVING ROOM C206 CO OUTLINE ATTIC ABOVE 206.1 UNIT C DECK 2 C207 UNIT C DECK 2 DECK-2 C207 F.F.E EAST TERRACE 111'-0" PRPT-CAP-2 11'-2 3/4" PRPT-CAP-2 TALL CAB W A - W 6 - R / G - 0 I I O U T L N E B U L D N G B E L O W I 2/G104 L DINING C202 CO SCO C204.1 KITCHENETTE C204 C204 WD-3 C205.1 OFFICE BATH C205 C205 TILE 205.1 E S A C K O O B BOOKCASE C203.1 " 8 - ' 2 C 2 0 3 . 1 S OUTLINE OF WALL BELOW OFFICE / ADU C203 C203 WD-3 WA-W6-R/G-0 COLS. DOWN W A - W 6 - R / G - 0 PRPT-CAP-2 C203.2 F.F.E EAST TERRACE-N 111'-0" UNIT C DECK 2 C206 C206 DECK-2 DN 18 17 16 STAIR B 18 R @7 21/64" 17 T @10" UP 1/G104 5 1 4 1 3 1 2 1 1 1 0 1 123456789 2'-4" 8" 4'-6" 8" STAIR B WA-W6-M/M-0 " 8 / 7 8 - ' 7 " 4 / 1 2 - ' 5 " 2 / 1 5 " 4 / 3 4 - ' 8 1 " 2 / 1 3 - ' 0 1 " 1 1 - ' 0 1 " 8 / 7 7 - ' 0 1 " 4 / 1 0 1 " 8 - ' 2 " 9 - ' 6 " 1 1 - ' 1 " 8 - ' 6 " 4 - ' 1 " 8 - ' 4 " 1 1 - ' 4 " 2 / 1 8 - ' 9 B C D D1 A D2 E F G H J K 3 0 7 8 7 ● s a x e T , n i t s u A ● e c r i l l C e e n w o r B 5 0 7 N W R B I E C N E D S E R T N U - 4 W E N I 1220 Lavaca Street Austin, TX, 78701 WebberStudio.com CURRENT ISSUE CDPROC50 14 May 2025 REVISIONS MARK DATE ISSUE 05.13.25 CDPROC49 PERMIT A112 DIMENSION FLOOR PLAN : 2nd LEVEL NOTE: LEVEL 1 FINISH FLOOR ELEVATION: +516.58' = +516'-7" = +100'-0" DIMENSION FLOOR PLAN : 2nd LEVEL SCALE: 1/4" = 1'-0" 1 29 OF 117 N COPYRIGHT © 2025 WEBBER+STUDIO ARCHITECTS 17'-8 1/4" 17'-2 3/8" 3'-2 3/4" 6'-0" 7'-1 1/4" 8'-2 1/4" 87'-3 1/4" 5 1/2" 5 1/2" 40'-5" 3 1/2" 1'-7 5/8" 24'-0 5/8" 11'-9 5/8" 2'-10 1/4" 2'-0" 5 1/2" 5 7/8" 3 1/2" 2'-7 1/2" 5 1/2" 5'-6 1/2" 5 1/2" 7'-8 3/4" 18'-8 1/4" 4'-11 1/2" 6'-0 1/8" 9'-10 1/8" 2 2.4 3 3 4 5 6 7 12'-0" 11'-6 1/4" C1 2 3/4" 6" 2 3/4" 1 9'-0 1/4" 2 1'-2" 1.75 " 8 - ' 2 " 9 - ' 6 " 1 1 - ' 1 " 8 - ' 6 " 4 - ' 1 " 8 - ' 4 B C D D1 D2 E F " 4 / 3 2 J K M P 6 3 : 1 | 5 2 0 2 , 4 1 y a M , y a d s e n d e W | # # # # . r e V | 3 0 3 0 5 2 _ N W R B / T O D U T S / 7 2 d a c h c r A I i r o f i c s a B d u o c M B - I l l a c o l . 7 2 d u o c M B I l : l d u o c M B I 2 2.4 3 3 9'-0 1/4" 1.75 6'-0" 8'-2 1/4" 24'-0 5/8" 1'-6 1/4" 1 1.5 WA-W6-R/W-0 A PRPT-CAP-1 " 8 / 2 7 4'- A1 4'-0" A2 5 6 7 FIRE RATED ASSEMBLIES 1-HOUR RATED ASSEMBLY 2-HOUR RATED ASSEMBLY GARAGE CEILING ASSEMBLY SMOKE DETECTOR LEGEND S SMOKE DETECTOR TO BE HARDWIRED AND INTERCONNECTED PER CODE SCO SMOKE DETECTOR TO BE HARDWIRED AND INTERCONNECTED PER CODE @CEILING CO CO ALARM NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION 05/08/2025 4 L L A W D U T S G N I T S I X E E N L R E T N E C I PLANTER 0 - G / R - 6 W - A W 2 - G / R - 6 W - A W 2 / A 6 0 4 L L A W D U T S G N I T S I X E E N L R E T N E C I 6'-4" 3'-4" 1/A602 1/A601 C200.1 OPEN F.F.E PH 124'-4" C302.1 STORAGE C302 C301.1 C PENTHOUSE F.F.E PH C301 124'-4" S 3/A604 C301.2 ELEV. ELEV. VOID DN STAIR A 21 20 19 18 17 16 15 14 13 12 11 10 4 0 6 A / 2 9 8 UP " 8 / 5 7 @ R 1 2 " 8 / 3 1 1 @ T 0 2 1 2 3 4 5 6 7 8 C200.3 1/A602 1/A601 A2 PRPT-CAP-1 C1 0 - G / R - 6 W - A W DRIP-1 OPEN WA-W6-R/G-0 WA-W6-R/W-0 POOL UNIT C ROOF DECK F.F.E ROOF DECK 124'-4" C303 UNIT C ROOF DECK 12'-0" C1 " 8 - ' 8 " 8 - ' 6 1.75 1 B C D D1 D2 E F J K M P 6 3 : 1 | 5 2 0 2 , 4 1 y a M , y a d s e n d e W | # # # # . r e V | 3 0 3 0 5 2 _ N W R B / T O D U T S / 7 2 d a c h c r A I i r o f i c s a B d u o c M B - I l l a c o l . 7 2 d u o c M B I l : l d u o c M B I LINE OF MECHANICAL PENTHOUSE BELOW " 8 - ' 2 " 9 - ' 6 " 1 1 - ' 9 " 8 - ' 4 " 1 1 - ' 4 " 2 / 1 8 - ' 9 " 4 / 1 2 - ' 5 " 2 / 1 3 - ' 0 1 B C D D1 A D2 E F G H J K 2/G104 1/G104 3 0 7 8 7 ● s a x e T , n i t s u A ● e c r i l l C e e n w o r B 5 0 7 N W R B I E C N E D S E R T N U - 4 W E N I 1220 Lavaca Street Austin, TX, 78701 WebberStudio.com CURRENT ISSUE CDPROC50 14 May 2025 REVISIONS MARK DATE ISSUE 05.13.25 CDPROC49 PERMIT A113 DIMENSION FLOOR PLAN : PH & ROOF DECK 30 OF 117 6'-0" 8'-2 1/4" 24'-0 5/8" 11'-9 5/8" 2'-10 1/4" 2'-0" 2 2.4 3 3 4 5 6 7 NOTE: LEVEL 1 FINISH FLOOR ELEVATION: +516.58' = +516'-7" = +100'-0" DIMENSION FLOOR PLAN : PH & ROOF DECK SCALE: 1/4" = 1'-0" 1 COPYRIGHT © 2025 WEBBER+STUDIO ARCHITECTS N A A1 4'-0" A2 12'-0" C1 2 2.4 3 3 1'-6 1/4" 1 1.5 9'-0 1/4" 1.75 6'-0" 8'-2 1/4" 24'-0 5/8" L L A W D U T S G N I T S I X E E N L R E T N E C I PRPT-CAP-1 DRIP-1 PRPT-CAP-3 ASSY-36 H C T I P 2 1 : " 4 / 1 5 6 7 4 L L A W D U T S G N I T S I X E E N L R E T N E C I NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION 05/08/2025 GUTTR-1 CENTERLINE EXISTING STUD WALL CENTERLINE EXISTING STUD WALL GUTTR-1 SLOPE 4:12 RA-01 A2 CRICKET HIP CAP CENTERLINE EXISTING STUD WALL 1 1.75 C1 E P O L S 2 1 : 4 / 3 2 RA-01 GTTR-1 DRIP-1 CENTERLINE EXISTING STUD WALL GUTTR-1 CENTERLINE EXISTING STUD WALL " 8 - ' 2 " 9 - ' 6 " 1 1 - ' 9 " 8 - ' 4 " 1 1 - ' 4 " 2 / 1 8 - ' 9 " 4 / 1 2 - ' 5 " 2 / 1 3 - ' 0 1 B C D D1 A D2 E F G H J K 3 0 7 8 7 ● s a x e T , n i t s u A ● e c r i l l C e e n w o r B 5 0 7 N W R B I E C N E D S E R T N U - 4 W E N I 1220 Lavaca Street Austin, TX, 78701 WebberStudio.com CURRENT ISSUE CDPROC50 14 May 2025 REVISIONS MARK DATE ISSUE 05.13.25 CDPROC49 PERMIT A114 DIMENSION FLOOR PLAN : ROOF 31 OF 117 COPYRIGHT © 2025 WEBBER+STUDIO ARCHITECTS N 6'-0" 8'-2 1/4" 24'-0 5/8" 11'-9 5/8" 2'-10 1/4" 2'-0" 2 2.4 3 3 4 5 6 7 NOTE: LEVEL 1 FINISH FLOOR ELEVATION: +516.58' = +516'-7" = +100'-0" DIMENSION FLOOR PLAN : ROOF SCALE: 1/4" = 1'-0" 1 B C D D1 D2 E F J K M P 6 3 : 1 | 5 2 0 2 , 4 1 y a M , y a d s e n d e W | # # # # . r e V | 3 0 3 0 5 2 _ N W R B / T O D U T S / 7 2 d a c h c r A I i r o f i c s a B d u o c M B - I l l a c o l . 7 2 d u o c M B I l : l d u o c M B I A1 4'-0" STAIR D M P 6 3 : 1 | 5 2 0 2 , 4 1 y a M , y a d s e n d e W | # # # # . r e V | 4'-0" 4'-0" " 4 - ' 2 EQUIPMENT HT: 7'-4" GWB-1 STORAGE HT: 7'-4" GWB-1 STORAGE CLOSET Q E HT: 7'-4" GWB-1 HALL HT: 7'-4" GWB-1 EQ MECH CLOSET HT: 7'-4" GWB-1 Q E Q E 3'-0" E Q BBQ/OUTDOOR KITCHEN HT: 7'-4" SOFF-1 E Q C DOOR ELEV. 3'-4" 2'-5 1/4" UNIT D DECK 0 2'-8" 2'-8" UNIT D POOL DEN HT: 7'-4" GWB-1 POOL DEN HT: 8'-8" GWB-X EQ A2 SECRET ROOM HT: 7'-4" GWB-1 EQ EQ EQ HT: 8'-8" " 2 / 1 9 - ' 2 2'-8 1/8" F1 3'-10" 3'-10" C1 BATH HT: 7'-4" GWB-1 UNIT B SLAB ABOVE " 1 - ' 6 " 6 - ' 5 " 4 - ' 3 3'-9" W2 I UNIT A SLAB ABOVE 3 0 3 0 5 2 _ N W R B / T O D U T S / 7 2 d a c h c r A I i r o f i c s a B d u o c M B - I l l a c o l . 7 2 d u o c M B I l : l d u o c M B I FIRE RATED ASSEMBLIES GENERAL LIGHTING LAYOUT NOTES 1-HOUR RATED ASSEMBLY 2-HOUR RATED ASSEMBLY GARAGE CEILING ASSEMBLY UNLESS NOTED OTHERWISE, LIGHTING SHALL BE LAID OUT AS FOLLOWS: - HEIGHT AS NOTED ON SCHEDULE; - SINGLE-FIXTURE TO BE CENTERED IN ROOM, BOTH WAYS; - FIXTURE-STRING TO BE LAID OUT THUS (WHERE "L" UNINTERRUPTED WALL LENGHT, UNLESS NOTED OTHERWISE): **DIVIDE ROOM DIMENSION "L" BY NUMBER OF FIXTURES IN STRING... X/2 X X/2 X/2 X X X/2 UNINTERRUPTED WALL LENGTH L UNINTERRUPTED WALL LENGTH L ...SO THAT X=L/# OF FIXTURES 2'-0"-3'-4" MEP LEGEND SYMBOL DESCRIPTION # # # # # # L L L RECESSED CEILING LUMINAIRE RECESSED ACCENT/ADJUSTABLE/ DIRECTIONAL CEILING LUMINAIRE SURFACE MOUNTED LUMINAIRE SURFACE MOUNTED DIRECTIONAL LUMINAIRE PENDANT LUMINAIRE WALL MOUNTED LUMINAIRE # RECESSED WALL LUMINAIRE CONCEALED COVE LUMINAIRE UNDER-CABINET LINEAR LUMINAIRE EXPOSED LINEAR LUMINAIRE EXPOSED LINEAR LUMINAIRE WITH TRACK HEADS IN QUANTITY SHOWN RECESSED LINEAR WALL LUMINAIRE RECESSED IN-GROUND/IN-FLOOR UPLIGHTING LUMINAIRE RECESSED IN-GROUND/IN-FLOOR DIRECTIONAL LUMINAIRE SURFACE MOUNTED IN-GROUND/IN-FLOOR UPLIGHTING LUMINAIRE SURFACE MOUNTED IN-GROUND/IN-FLOOR DIRECTIONAL LUMINAIRE LANDSCAPE LUMINAIRE CEILING FAN WITHOUT LIGHT CEILING FAN WITH LIGHT NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION 05/08/2025 3 0 7 8 7 ● s a x e T , n i t s u A ● e c r i l l C e e n w o r B 5 0 7 I E C N E D S E R T N U - 4 W E N I 2/G104 J CIRCUIT WIRING SWITCH DIMMER SWITCH JAMB SWITCH HINGE SWITCH SENSOR SWITCH TIMER SWITCH THREE-WAY SWITCH FOUR-WAY SWITCH D J H S T 3 4 KP KEYPAD CONTROL N W R B X" X" GFCI X" GFIX X" X" 220 T S C D M DB CH DUPLEX OUTLET (NUMBER INDICATES HEIGHT IN INCHES ABOVE FINISHED FLOOR) DUPLEX OUTLET WITH GROUND FAULT INTERRUPTER (NUMBER INDICATES HEIGHT IN INCHES ABOVE FINISHED FLOOR) DUPLEX OUTLET RATED FOR EXTERIOR USE WITH GROUND FAULT INTERRUPTER (NUMBER INDICATES HEIGHT IN INCHES ABOVE FINISHED FLOOR) FOURPLEX OUTLET SWITCHED OUTLET (HALF HOT) FLOOR OUTLET 220V OUTLET TELEPHONE / DATA / CABLE TV COMBINATION TELEPHONE / DATA / CABLE TV COMBINATION FLOOR JACK SPEAKER (CEILING) SPEAKER (RECESSED WALL) THERMOSTAT 1220 Lavaca Street Austin, TX, 78701 WebberStudio.com SMOKE DETECTOR / CARBON MONOXIDE CURRENT ISSUE DOORBELL DOORBELL CHIME EXHAUST FAN CDPROC50 14 May 2025 REVISIONS MARK DATE ISSUE 05.13.25 CDPROC49 PERMIT 1/G104 EXHAUST FAN (WALL) S A SUPPLY AIR REGISTER CEILING (OR FLOOR) R A HB H C G SUPPLY AIR REGISTER (WALL) RETURN AIR GRILLE CEILING (OR FLOOR) RETURN AIR GRILLE (WALL) HOSE BIB HOT AND COLD WATER CONNECTIONS GAS CONNECTION RCP : BASEMENT SCALE: 1/4" = 1'-0" 1 N A120 RCP : BASEMENT 32 OF 117 COPYRIGHT © 2025 WEBBER+STUDIO ARCHITECTS FIRE RATED ASSEMBLIES GENERAL LIGHTING LAYOUT NOTES 1-HOUR RATED ASSEMBLY 2-HOUR RATED ASSEMBLY GARAGE CEILING ASSEMBLY UNLESS NOTED OTHERWISE, LIGHTING SHALL BE LAID OUT AS FOLLOWS: - HEIGHT AS NOTED ON SCHEDULE; - SINGLE-FIXTURE TO BE CENTERED IN ROOM, BOTH WAYS; - FIXTURE-STRING TO BE LAID OUT THUS (WHERE "L" UNINTERRUPTED WALL LENGHT, UNLESS NOTED OTHERWISE): **DIVIDE ROOM DIMENSION "L" BY NUMBER OF FIXTURES IN STRING... X/2 X X/2 X/2 X X X/2 UNINTERRUPTED WALL LENGTH L UNINTERRUPTED WALL LENGTH L ...SO THAT X=L/# OF FIXTURES 2'-0"-3'-4" EQ A Q E Q E 2 UNIT C LOBBY HT: 9'-0" GWB-1 Q E 6'-0" EQ EQ SOFF-1 BEDROOM HT: 8'-0" GWB-1 2 / Y Y BATHROOM HT: 7'-4" GWB-1 DB X/2 X X/2 2 / Y I A R A T S ELEV. ELEV CLOSET HT: 9'-0" GYP BD 2 1'-1 1/2" DR X/2 X X/2 EQ EQ CH UC RG 2 / Y Y SOFF-1 A1 SOFF-1 " 4 / 3 4 - ' 2 E Q A EQ B EQ B EQ B STAIR D GARAGE HT: 9'-0 3/4" UNIT C GWB-1 C Q E D Q E D Q E D Q E " 0 - C ' 4 Q E 2'-8 1/4" A2 STAIR C " 1 - ' 3 C1 UNIT C DECK 1 M P 6 3 : 1 | 5 2 0 2 , 4 1 y a M , y a d s e n d e W | # # # # . r e V | 3 0 3 0 5 2 _ N W R B / T O D U T S / 7 2 d a c h c r A I i r o f i c s a B d u o c M B - I l l a c o l . 7 2 d u o c M B I l : l d u o c M B I R Y X/2 2 / Y R I Y X/2 Y Y Y KITCHEN HT: 7'-4" GWB-1 KITCHEN CASWORK BELOW Y LIVING HT: 8'-0" GWB-1 X X/2 RG HT: 7'-4" 5'-3 7/8" KITCHEN HT: 9'-0" GWB-1 UC 2 / Y Y 2 / Y W D X/2 2 / Y X X/2 KITCHEN ISLAND BELOW LIVING HT: 9'-0" GWB-1 X/2 X X EQ EQ EQ EQ R D X/2 X X/2 A S BEDROOM HT: 9'-0" GWB-1 A R WALL C C R O O D BATHROOM HT: 7'-4" GYP BD 2 DOOR C BATHROOM HT: 7'-4" GWB-1 2 / Y Y 2 / Y 2 / Y Y 2 / Y D B X/2 X X/2 BEDROOM HT: 9'-0" GWB-1 STAIR B RCP : FIRST LEVEL SCALE: 1/4" = 1'-0" 1 N MEP LEGEND SYMBOL DESCRIPTION # # # # # # L L L RECESSED CEILING LUMINAIRE RECESSED ACCENT/ADJUSTABLE/ DIRECTIONAL CEILING LUMINAIRE SURFACE MOUNTED LUMINAIRE SURFACE MOUNTED DIRECTIONAL LUMINAIRE PENDANT LUMINAIRE WALL MOUNTED LUMINAIRE # RECESSED WALL LUMINAIRE CONCEALED COVE LUMINAIRE UNDER-CABINET LINEAR LUMINAIRE EXPOSED LINEAR LUMINAIRE EXPOSED LINEAR LUMINAIRE WITH TRACK HEADS IN QUANTITY SHOWN RECESSED LINEAR WALL LUMINAIRE RECESSED IN-GROUND/IN-FLOOR UPLIGHTING LUMINAIRE RECESSED IN-GROUND/IN-FLOOR DIRECTIONAL LUMINAIRE SURFACE MOUNTED IN-GROUND/IN-FLOOR UPLIGHTING LUMINAIRE SURFACE MOUNTED IN-GROUND/IN-FLOOR DIRECTIONAL LUMINAIRE LANDSCAPE LUMINAIRE CEILING FAN WITHOUT LIGHT CEILING FAN WITH LIGHT J CIRCUIT WIRING SWITCH DIMMER SWITCH JAMB SWITCH HINGE SWITCH SENSOR SWITCH TIMER SWITCH THREE-WAY SWITCH FOUR-WAY SWITCH D J H S T 3 4 KP KEYPAD CONTROL NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION 05/08/2025 3 0 7 8 7 ● s a x e T , n i t s u A ● e c r i l l C e e n w o r B 5 0 7 N W R B I E C N E D S E R T N U - 4 W E N I X" X" GFCI X" GFIX X" X" 220 T S C D M DB CH DUPLEX OUTLET (NUMBER INDICATES HEIGHT IN INCHES ABOVE FINISHED FLOOR) DUPLEX OUTLET WITH GROUND FAULT INTERRUPTER (NUMBER INDICATES HEIGHT IN INCHES ABOVE FINISHED FLOOR) DUPLEX OUTLET RATED FOR EXTERIOR USE WITH GROUND FAULT INTERRUPTER (NUMBER INDICATES HEIGHT IN INCHES ABOVE FINISHED FLOOR) FOURPLEX OUTLET SWITCHED OUTLET (HALF HOT) FLOOR OUTLET 220V OUTLET TELEPHONE / DATA / CABLE TV COMBINATION TELEPHONE / DATA / CABLE TV COMBINATION FLOOR JACK SPEAKER (CEILING) SPEAKER (RECESSED WALL) THERMOSTAT 1220 Lavaca Street Austin, TX, 78701 WebberStudio.com SMOKE DETECTOR / CARBON MONOXIDE CURRENT ISSUE DOORBELL DOORBELL CHIME EXHAUST FAN EXHAUST FAN (WALL) CDPROC50 14 May 2025 REVISIONS MARK DATE ISSUE 05.13.25 CDPROC49 PERMIT S A SUPPLY AIR REGISTER CEILING (OR FLOOR) R A HB H C G SUPPLY AIR REGISTER (WALL) RETURN AIR GRILLE CEILING (OR FLOOR) RETURN AIR GRILLE (WALL) HOSE BIB HOT AND COLD WATER CONNECTIONS GAS CONNECTION A121 RCP : 1st FLOOR 33 OF 117 COPYRIGHT © 2025 WEBBER+STUDIO ARCHITECTS FIRE RATED ASSEMBLIES GENERAL LIGHTING LAYOUT NOTES 1-HOUR RATED ASSEMBLY 2-HOUR RATED ASSEMBLY GARAGE CEILING ASSEMBLY UNLESS NOTED OTHERWISE, LIGHTING SHALL BE LAID OUT AS FOLLOWS: - HEIGHT AS NOTED ON SCHEDULE; - SINGLE-FIXTURE TO BE CENTERED IN ROOM, BOTH WAYS; - FIXTURE-STRING TO BE LAID OUT THUS (WHERE "L" UNINTERRUPTED WALL LENGHT, UNLESS NOTED OTHERWISE): **DIVIDE ROOM DIMENSION "L" BY NUMBER OF FIXTURES IN STRING... X/2 X X/2 X/2 X X X/2 UNINTERRUPTED WALL LENGTH L UNINTERRUPTED WALL LENGTH L ...SO THAT X=L/# OF FIXTURES 2'-0"-3'-4" EQ Q E EQ F1 PR HT: 9'-4" GWB-1 Q E CH CH HT: 9'-4" STAIR A HT: 20'-5" HT HIGH: 21'-0" KITCHEN WD-4 EQ EQ EQ 2'-0" EQ 2'-6 3/4" EQ EQ C DOOR 2'-4" " 8 / 3 0 1 - ' 3 " 8 / 3 0 1 - ' 3 " 4 - ' 3 " 0 - ' 2 Q E Q E UNIT C LIVING ROOM WD-4 DINING WD-4 C V T HT LOW: 15'-5" 3'-4" " 4 - ' 3 UNIT C DECK 2 Q E Q E Q E Q E W2 W2 F1 BATH HT: 8'-3/4" GYP BD 2 " 0 1 - ' 3 2'-5" HT LOW: 9'-3" " 8 - ' 2 X X 2 " 0 2 ' - OFFICE/ADU HT: 8'-0" GWB-1 X X 2X X Q E Q E E Q E Q PETER'S ROOM HT: 9'-4" GWB-1 C DOOR 3'-6 1/4" 2'-0" EQA E Q B E Q E Q EQA VESTIBULE HT: 9'-4" GWB-1 EQA EQA 2'-0" ELEV C DOOR EQ EQ M. CLOSET HT: 9'-4" GWB-1 Q E Q E EQ EQ HT: 9'-11 1/4" W / D STAIR C A2 C1 MEP LEGEND SYMBOL DESCRIPTION # # # # # # L L L RECESSED CEILING LUMINAIRE RECESSED ACCENT/ADJUSTABLE/ DIRECTIONAL CEILING LUMINAIRE SURFACE MOUNTED LUMINAIRE SURFACE MOUNTED DIRECTIONAL LUMINAIRE PENDANT LUMINAIRE WALL MOUNTED LUMINAIRE # RECESSED WALL LUMINAIRE CONCEALED COVE LUMINAIRE UNDER-CABINET LINEAR LUMINAIRE EXPOSED LINEAR LUMINAIRE EXPOSED LINEAR LUMINAIRE WITH TRACK HEADS IN QUANTITY SHOWN RECESSED LINEAR WALL LUMINAIRE RECESSED IN-GROUND/IN-FLOOR UPLIGHTING LUMINAIRE RECESSED IN-GROUND/IN-FLOOR DIRECTIONAL LUMINAIRE SURFACE MOUNTED IN-GROUND/IN-FLOOR UPLIGHTING LUMINAIRE SURFACE MOUNTED IN-GROUND/IN-FLOOR DIRECTIONAL LUMINAIRE LANDSCAPE LUMINAIRE CEILING FAN WITHOUT LIGHT CEILING FAN WITH LIGHT J CIRCUIT WIRING SWITCH DIMMER SWITCH JAMB SWITCH HINGE SWITCH SENSOR SWITCH TIMER SWITCH THREE-WAY SWITCH FOUR-WAY SWITCH D J H S T 3 4 KP KEYPAD CONTROL NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION 05/08/2025 3 0 7 8 7 ● s a x e T , n i t s u A ● e c r i l l C e e n w o r B 5 0 7 N W R B I E C N E D S E R T N U - 4 W E N I X" X" GFCI X" GFIX X" X" 220 T S C D M DB CH DUPLEX OUTLET (NUMBER INDICATES HEIGHT IN INCHES ABOVE FINISHED FLOOR) DUPLEX OUTLET WITH GROUND FAULT INTERRUPTER (NUMBER INDICATES HEIGHT IN INCHES ABOVE FINISHED FLOOR) DUPLEX OUTLET RATED FOR EXTERIOR USE WITH GROUND FAULT INTERRUPTER (NUMBER INDICATES HEIGHT IN INCHES ABOVE FINISHED FLOOR) FOURPLEX OUTLET SWITCHED OUTLET (HALF HOT) FLOOR OUTLET 220V OUTLET TELEPHONE / DATA / CABLE TV COMBINATION TELEPHONE / DATA / CABLE TV COMBINATION FLOOR JACK SPEAKER (CEILING) SPEAKER (RECESSED WALL) THERMOSTAT 1220 Lavaca Street Austin, TX, 78701 WebberStudio.com SMOKE DETECTOR / CARBON MONOXIDE CURRENT ISSUE DOORBELL DOORBELL CHIME EXHAUST FAN EXHAUST FAN (WALL) CDPROC50 14 May 2025 REVISIONS MARK DATE ISSUE 05.13.25 CDPROC49 PERMIT 2'-4" 8" 4'-6" 8" STAIR B RCP : SECOND LEVEL SCALE: 1/4" = 1'-0" 1 N S A SUPPLY AIR REGISTER CEILING (OR FLOOR) R A HB H C G SUPPLY AIR REGISTER (WALL) RETURN AIR GRILLE CEILING (OR FLOOR) RETURN AIR GRILLE (WALL) HOSE BIB HOT AND COLD WATER CONNECTIONS GAS CONNECTION A122 RCP : 2nd FLOOR 34 OF 117 COPYRIGHT © 2025 WEBBER+STUDIO ARCHITECTS " 4 5'- A1 3'-1" C E Q E Q BATH HT: 9'-4" GYP BD 2 2'-4" F 1 EQ EQ 3'-6 3/8" E Q B C WIN D O W E Q E Q M. BATH HT: 9'-4" GYP BD 2 D O O R C E Q 4'-0" X M. BEDROOM HT: 9'-4" GWB-1 2X E Q X M P 6 3 : 1 | 5 2 0 2 , 4 1 y a M , y a d s e n d e W | # # # # . r e V | 3 0 3 0 5 2 _ N W R B / T O D U T S / 7 2 d a c h c r A I i r o f i c s a B d u o c M B - I l l a c o l . 7 2 d u o c M B I l : l d u o c M B I A1 M P 6 3 : 1 | 5 2 0 2 , 4 1 y a M , y a d s e n d e W | # # # # . r e V | UNIT C ROOF DECK STORAGE GWB-1 HT: 8'-0" Q E Q E EQ EQ W2 3'-0" PENTHOUSE C HT: 8'-0" GWB-1 Q E " 0 1 - ' 3 " 0 1 - ' 3 Q E STAIR A ELEV. ELEV A2 C1 3 0 3 0 5 2 _ N W R B / T O D U T S / 7 2 d a c h c r A I i r o f i c s a B d u o c M B - I l l a c o l . 7 2 d u o c M B I l : l d u o c M B I FIRE RATED ASSEMBLIES GENERAL LIGHTING LAYOUT NOTES 1-HOUR RATED ASSEMBLY 2-HOUR RATED ASSEMBLY GARAGE CEILING ASSEMBLY UNLESS NOTED OTHERWISE, LIGHTING SHALL BE LAID OUT AS FOLLOWS: - HEIGHT AS NOTED ON SCHEDULE; - SINGLE-FIXTURE TO BE CENTERED IN ROOM, BOTH WAYS; - FIXTURE-STRING TO BE LAID OUT THUS (WHERE "L" UNINTERRUPTED WALL LENGHT, UNLESS NOTED OTHERWISE): **DIVIDE ROOM DIMENSION "L" BY NUMBER OF FIXTURES IN STRING... X/2 X X/2 X/2 X X X/2 UNINTERRUPTED WALL LENGTH L UNINTERRUPTED WALL LENGTH L ...SO THAT X=L/# OF FIXTURES 2'-0"-3'-4" MEP LEGEND SYMBOL DESCRIPTION # # # # # # L L L RECESSED CEILING LUMINAIRE RECESSED ACCENT/ADJUSTABLE/ DIRECTIONAL CEILING LUMINAIRE SURFACE MOUNTED LUMINAIRE SURFACE MOUNTED DIRECTIONAL LUMINAIRE PENDANT LUMINAIRE WALL MOUNTED LUMINAIRE # RECESSED WALL LUMINAIRE CONCEALED COVE LUMINAIRE UNDER-CABINET LINEAR LUMINAIRE EXPOSED LINEAR LUMINAIRE EXPOSED LINEAR LUMINAIRE WITH TRACK HEADS IN QUANTITY SHOWN RECESSED LINEAR WALL LUMINAIRE RECESSED IN-GROUND/IN-FLOOR UPLIGHTING LUMINAIRE RECESSED IN-GROUND/IN-FLOOR DIRECTIONAL LUMINAIRE SURFACE MOUNTED IN-GROUND/IN-FLOOR UPLIGHTING LUMINAIRE SURFACE MOUNTED IN-GROUND/IN-FLOOR DIRECTIONAL LUMINAIRE LANDSCAPE LUMINAIRE CEILING FAN WITHOUT LIGHT CEILING FAN WITH LIGHT J CIRCUIT WIRING SWITCH DIMMER SWITCH JAMB SWITCH HINGE SWITCH SENSOR SWITCH TIMER SWITCH THREE-WAY SWITCH FOUR-WAY SWITCH D J H S T 3 4 KP KEYPAD CONTROL NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION 05/08/2025 3 0 7 8 7 ● s a x e T , n i t s u A ● e c r i l l C e e n w o r B 5 0 7 N W R B I E C N E D S E R T N U - 4 W E N I X" X" GFCI X" GFIX X" X" 220 T S C D M DB CH DUPLEX OUTLET (NUMBER INDICATES HEIGHT IN INCHES ABOVE FINISHED FLOOR) DUPLEX OUTLET WITH GROUND FAULT INTERRUPTER (NUMBER INDICATES HEIGHT IN INCHES ABOVE FINISHED FLOOR) DUPLEX OUTLET RATED FOR EXTERIOR USE WITH GROUND FAULT INTERRUPTER (NUMBER INDICATES HEIGHT IN INCHES ABOVE FINISHED FLOOR) FOURPLEX OUTLET SWITCHED OUTLET (HALF HOT) FLOOR OUTLET 220V OUTLET TELEPHONE / DATA / CABLE TV COMBINATION TELEPHONE / DATA / CABLE TV COMBINATION FLOOR JACK SPEAKER (CEILING) SPEAKER (RECESSED WALL) THERMOSTAT 1220 Lavaca Street Austin, TX, 78701 WebberStudio.com SMOKE DETECTOR / CARBON MONOXIDE CURRENT ISSUE DOORBELL DOORBELL CHIME EXHAUST FAN EXHAUST FAN (WALL) CDPROC50 14 May 2025 REVISIONS MARK DATE ISSUE 05.13.25 CDPROC49 PERMIT A123 RCP : PENTHOUSE 35 OF 117 COPYRIGHT © 2025 WEBBER+STUDIO ARCHITECTS S A SUPPLY AIR REGISTER CEILING (OR FLOOR) R A HB H C G SUPPLY AIR REGISTER (WALL) RETURN AIR GRILLE CEILING (OR FLOOR) RETURN AIR GRILLE (WALL) HOSE BIB HOT AND COLD WATER CONNECTIONS GAS CONNECTION RCP : PENTHOUSE SCALE: 1/4" = 1'-0" 1 N PP AUTOMATIC GATE P U UP DN DN NEW PERVIOUS PAVING ASSEMBLY SUB-SURFACE DRAINAGE SYSTEM PUMPED TO LOW POINT OF FRONT PROPERTY LINE PP CO CO RELOCATE EXISTING CLEAN OUT REMOVE EXISTING WATER REMOVE EXISTING WATER METERS & ADD NEW SERVICE & METERS & ADD NEW SERVICE & METERS METERS ) . 5,025 GAL. UNDERGROUND WATER STORAGE TANK HVAC & POOL EQUIPMENT BELOW CANTILEVERED PARKING DECK REMOVE EXISTING OVERHEAD ELECTRICAL LINE SUB-SURFACE DRAINAGE SYSTEM D N 879 U P NEW POOL PP PP 875 E E E E E G G REMOVE EXISTING ELECTRIC METERS NEW UNDERGROUND ELECTRIC & COMMUNICATION LINE REMOVE EXISTING ELECTRICAL OVERHEAD ELECTRICAL SERVICE REMOVE 2 GAS METERS + INSTALL 1 NEW NEW ELECTRIC METERS + PANELS . . I W O R H T D W E L B A R A V ( I N01 W W W . I . C " 6 . I . C " 2 I E L C R C E E L N W O R B 872 EXISTING GAS LINE CO MEP SITE PLAN SCALE: 1/8" = 1'-0" 1 N NOTE: LEVEL 1 FINISH FLOOR ELEVATION: +516.58' = +516'-7" = +100'-0" M P 6 3 : 1 | 5 2 0 2 , 4 1 y a M , y a d s e n d e W | # # # # . r e V | 3 0 3 0 5 2 _ N W R B / T O D U T S / 7 2 d a c h c r A I i r o f i c s a B d u o c M B - I l l a c o l . 7 2 d u o c M B I l : l d u o c M B I SITE / LOT PLAN LEGEND PROPERTY LINE SET BACK LINE TREE (C.R.Z) CANOPY LINE OVERHEAD UTILITY LINE GAS LINE WATER LINE ELECTRIC LINE WOOD BOARD FENCE CHAIN LINK FENCE WIRE AND WOOD FENCE GAS METER ELECTRIC METER WATER METERS; (2) IN BOX CLEAN OUT AIR CONDITIONER POWER POLE WATER VALVE IRRIGATION CONTROL VALVE FIRE HYDRANT G E W CO PP WV PP Y D H TREE PROTECTION NOTES 12 GA. WIRE (OR STRAPS) STAPLED TO 2X6s. THIS METHOD PROTECTS TRUNK FROM DAMAGE BY CONSTRUCTION EQUIPMENT. IT DOES NOT PROTECT ROOTS FROM COMPACTION. BARRIER SHOULD EXTEND THE FULL DIAMETER OF THE TREE CROWN TREE TRUNK PROTECTION GALV'D CHAIN LINK FENCE MATERIAL SUPPORTED BY GALV'D MTL FENCE POSTS OR EQUIVALENT CONSTRUCTION FENCE. THIS METHOD PROTECTS TREE FROM ROOT COMPACTION FROM CONSTRUCTION EQUIPMENT. " 0 - ' 6 D E D N E M M O C E R TREE PROTECTION BARRIER IT IS THE ARCHITECT'S AND OWNER'S INTENT TO PROTECT ALL TREES IN PROXIMITY TO CONSTRUCTION AREA FROM DAMAGE OR INJURY DUE TO CONSTRUCTION. THE SUGGESTIONS FOR TREE PROTECTION PROVIDED ABOVE ARE EXPLICITLY NOT GUARANTEED TO FULLY PROTECT THE TREES. IT IS HIGHLY RECOMMENDED THAT A TREE SPECIALIST BE HIRED AND THAT SUCH COST BE REVIEWED WITH OWNER FOR APPROVAL PRIOR TO PROCUREMENT OF TREE SPECIALIST SERVICES. IF CONTRACTOR DOES NOT REVIEW WITH OWNER HIS OR HER WILLINGNESS OR NON- WILLINGNESS TO HIRE SUCH SPECIALIST, THEN IT WILL BE CONSTRUED AS CONTRACTOR'S WILLINGNESS TO ACCEPT LIABILITY FOR PROTECTING THE TREES FROM ANY DAMAGE THROUGHOUT THE CONSTRUCTION PROCESS. NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION 05/08/2025 05/08/2025 3 0 7 8 7 ● s a x e T , n i t s u A ● e c r i l l C e e n w o r B 5 0 7 N W R B I E C N E D S E R T N U - 4 W E N I EXAMPLE: 20 IN. DIAMETER TREE 1/4 CRZ 5'-0" 1/2 CRZ 10'-0" FULL CRZ 20'-0" 1220 Lavaca Street Austin, TX, 78701 WebberStudio.com 1/4 CRZ - NO IMPACT 1/2 CRZ - NO CUT/FILL > 4" FULL CRZ - PRESERVE 50% CITY CODE REQUIRES THAT PROPOSED DEVELOPMENTS DEMONSTRATE THAT TREES ARE PRESERVED TO THE MAXIMUM EXTENT REASONABLE AND FEASIBLE. TREE PRESERVATION IS EFFECTIVELY DEFINED AS ROOT SYSTEM PRESERVATION; A CRITICAL ROOT ZONE AREA (CRZ) IS ASSIGNED TO EACH TREE, BASED ON TRUNK DIAMETER SIZE. A MINIMUM OF 50% OF THE CRZ IS REQUIRED TO BE LEFT UNDISTURBED TO ACHIEVE MINIMAL CONFORMANCE WITH THE REGULATIONS. LEGAL DESCRIPTION PROJECT ADDRESS: 705 Brownlee Circle Austin Texas 78703 U.S.A. LEGAL DESCRIPTION: LOT 32 OF PARK VIEW, VOLUME 5, PAGE 69, PLAT RECORDS, TRAVIS CO.,TX DESCRIPTION OF WORK: DEMOLITION OF EXISTING DUPLEX AND CONSTRUCTION OF NEW 4-UNIT RESIDENCE OWNER'S NAME: BRAD HOSKINS & MELISSA SKIDMORE TREE LIST 872 875 879 N01 N02 N03 N04 N05 N06 N07 N08 N09 N10 N11 16.5" LIVE OAK 18" MESQUITE 25" PECAN TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD CURRENT ISSUE CDPROC50 14 May 2025 REVISIONS MARK DATE ISSUE 05.13.25 CDPROC49 PERMIT A129 MEP SITE PLAN 36 OF 117 COPYRIGHT © 2025 WEBBER+STUDIO ARCHITECTS SEA LEVEL +553.51' SEA LEVEL +552.45' T.O. CHIMNEY +136'-10 3/4" MAX. BLDG. HEIGHT +135'-10" T.O. ROOF & PARAPET +135'-9 1/2" T.O. PARAPET WALL +128'-4" F.F.E ROOF DECK +124'-4" B.O. CLG. SECOND FLOOR +120'-4" F.F.E SECOND FLOOR +111'-0" T.O.P. FIRST FLOOR +109'-0" SEA LEVEL +516.58' F.F.E FIRST LEVEL +100'-0" PRPT-CAP-1 MTL-1 SEA LEVEL +553.51' SEA LEVEL +552.45' T.O. CHIMNEY +136'-10 3/4" MAX. BLDG. HEIGHT +135'-10" T.O. ROOF & PARAPET +135'-9 1/2" T.O. PARAPET WALL +128'-4" F.F.E ROOF DECK +124'-4" MTL-XX RA-01 DRIP-2 GTTR-1 MTL-1 STN-1 DRIP-2 OPEN TO DECK UNIT C A109.1 8/A541 1/A541 C301.1 6/A541 1/A551 4/A551 1/A551 MTL-2 3 / A 5 5 1 C203.1 2 5 5 A / 2 1 5 5 A / 3 C209.2 C209.1 C215.1 2/A551 5/A551 2/A551 2/A541 STN - XX B101.1 OPEN TO LIVING C100.2 DRIP-1 PRPT-CAP-1 MTL-1 MTL-1 DRIP-2 STN-1 T.O.P. FIRST LEVEL +108'-0" F.F.E FIRST LEVEL +100'-0" MTL-XX 5/A541 8/A541 SLOPE 2 3/4:12 DRIP-1 MTL-1 BUILDING ELEVATION : NORTH SCALE: 1/4" = 1'-0" 1 B.O. CLG. SECOND FLOOR +120'-4" PL F.F.E SECOND FLOOR +111'-0" T.O.P. FIRST FLOOR +109'-0" SEA LEVEL +516.58' F.F.E FIRST LEVEL +100'-0" SEA LEVEL +512.45' AVERAGE GRADE +95'-10" 4/A551 2 5 5 A / 2 2 / A 5 5 2 C213.10 C213.9 C213.8 C213.7 C213.6 C213.5 C213.4 C213.3 C213.2 C213.1 2 5 5 A / 2 2 / A 5 5 2 6 / A 5 5 1 6 / A 5 5 1 5/A551 2/A541 B102.1 A102.1 A104.1 . I N O T A T N E S E R P E R R E T A W PL RAIL-1 STN-1 RAIL-1 T.O.P. FIRST LEVEL +108'-0" F.F.E FIRST LEVEL +100'-0" D001.3 D001.2 D001.1 8/A541 C003.2 D001.1 NOTE: LEVEL 1 FINISH FLOOR ELEVATION: +516.58' = +516'-7" = +100'-0" BUILDING ELEVATION : SOUTH SCALE: 1/4" = 1'-0" 2 NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION 05/08/2025 3 0 7 8 7 ● s a x e T , n i t s u A ● e c r i l l C e e n w o r B 5 0 7 N W R B I E C N E D S E R T N U - 4 W E N I 1220 Lavaca Street Austin, TX, 78701 WebberStudio.com CURRENT ISSUE CDPROC50 14 May 2025 REVISIONS MARK DATE ISSUE 05.13.25 CDPROC49 PERMIT A200 BUILDING ELEVATIONS N & S 42 OF 117 COPYRIGHT © 2025 WEBBER+STUDIO ARCHITECTS M P 6 3 : 1 | 5 2 0 2 , 4 1 y a M , y a d s e n d e W | # # # # . r e V | 3 0 3 0 5 2 _ N W R B / T O D U T S / 7 2 d a c h c r A I i r o f i c s a B d u o c M B - I l l a c o l . 7 2 d u o c M B I l : l d u o c M B I SEA LEVEL +553.51' SEA LEVEL +552.45' T.O. CHIMNEY +136'-10 3/4" MAX. BLDG. HEIGHT +135'-10" T.O. ROOF & PARAPET +135'-9 1/2" T.O. PARAPET WALL +128'-4" F.F.E ROOF DECK +124'-4" B.O. CLG. SECOND FLOOR +120'-4" F.F.E. SECOND FLOOR +111'-0" T.O.P. FIRST FLOOR +109'-0" SEA LEVEL +516.58' F.F.E FIRST LEVEL +100'-0" SEA LEVEL +553.51' SEA LEVEL +552.45' T.O. CHIMNEY +136'-10 3/4" MAX. BLDG. HEIGHT +135'-10" T.O. ROOF & PARAPET +135'-9 1/2" T.O. PARAPET WALL +128'-4" F.F.E ROOF DECK +124'-4" B.O. CLG. SECOND FLOOR +120'-4" F.F.E. SECOND FLOOR +111'-0" T.O.P. FIRST FLOOR +109'-0" T.O. RAIL +103'-0" SEA LEVEL +516.58' F.F.E FIRST LEVEL +100'-0" SEA LEVEL +512.45' AVERAGE GRADE +95'-10" M P 6 3 : 1 | 5 2 0 2 , 4 1 y a M , y a d s e n d e W | # # # # . r e V | 3 0 3 0 5 2 _ N W R B / T O D U T S / 7 2 d a c h c r A I i r o f i c s a B d u o c M B - I l l a c o l . 7 2 d u o c M B I l : l d u o c M B I MTL-1 MTL-1 DRIP-1 TRIM-1 TRIM-1 DRIP-2 STN-1 C203.2 C203.3 C203.4 C203.1 2/A541 5/A541 S L O P E 4 : 1 2 4/A551 1/A541 SLOPE 1 3/4:12 1 5 5 A / 6 6 / A 5 5 1 4/A551 1/A551 7/A551 1/A551 1/A551 SLOPE 1:12 PRPT-CAP-1 MTL-1 TRIM-1 MTL-2 TRIM-1 1 5 5 A / 3 C203.5 1 5 5 A / 6 C200.2 C209.2 C209.1 C215.1 C213.10 C213.9 C213.8 C213.7 C213.6 1 0 / A 5 5 1 1 5 5 A / 9 2 5 5 A / 2 1 5 5 A / 3 2/A551 8/A551 2/A551 5/A551 1/A501 A101.1 OPEN TO BEYOND B105.1 B104.1 C100.1 1 0 5 A / 1 1 0 5 A / 1 C100.1 1 0 5 A / 1 MTL-3 1 0 5 A / 1 2/A541 C101.1 1 0 5 A / 1 8/A541 8/A541 1/A501 1/A501 PRPT-CAP-1 SLOPE 1:12 1/A541 S L O P E 1 3 / 4 : 1 2 4/A551 2 5 5 A / 2 C213.5 C213.4 C213.3 C213.2 C213.1 " 2 - ' 3 2 5 5 A / 2 1/A552 5/A551 1 5 5 A / 3 1 5 5 A / 3 TRIM-1 MTL-2 MTL-1 RAIL-1 WD-5 FASCIA DRIP-2 C200.3 C203.3 C 100.2 SLOPE 4:12 6/A541 4/A551 2 5 5 A / 2 1/A552 1 5 5 A / 6 MTL-2 5/A541 C203.2 6/A552 1/A531 1/A531 A104.1 A106.1 A107.1 A111.1 8/A541 NOT FOR REGULATORY APPROVAL, PERMITTING OR CONSTRUCTION 05/08/2025 3 0 7 8 7 ● s a x e T , n i t s u A ● e c r i l l C e e n w o r B 5 0 7 N W R B I E C N E D S E R T N U - 4 W E N I 1220 Lavaca Street Austin, TX, 78701 WebberStudio.com CURRENT ISSUE CDPROC50 14 May 2025 REVISIONS MARK DATE ISSUE 05.13.25 CDPROC49 PERMIT T.O.P. FIRST LEVEL +108'-0" DRIP-2 F.F.E FIRST LEVEL +100'-0" BUILDING ELEVATION : WEST SCALE: 1/4" = 1'-0" 1 CLAD CHIMNEY STN-1 RA-01 TRIM-1 TRIM-1 DRIP-1 MTL-1 TRIM-1 T.O. WINDOW T.O. DOORS " 8 / 1 1 - ' 5 1 " 0 - ' 8 " 2 - ' 3 T.O. SILL F.F.E. SECOND FLOOR +110'-0" SCUPPER FOR ROOF DECK DRIP-2 T.O.P. FIRST LEVEL +108'-0" STN-1 F.F.E FIRST LEVEL +100'-0" BUILDING ELEVATION : EAST SCALE: 1/4" = 1'-0" 2 NOTE: LEVEL 1 FINISH FLOOR ELEVATION: +516.58' = +516'-7" = +100'-0" A201 BUILDING ELEVATIONS E & W 43 OF 117 COPYRIGHT © 2025 WEBBER+STUDIO ARCHITECTS