04.1 - 905 Congress Ave - Photos and Drawings — original pdf
Backup

905 entry and main window 2021-todayDouble entry doors and metal canopyca. 1930Single off-set entry door. metal canopy with glass blockwindow ca. 1970905 1940's - Austin History Center, Austin Public Library.905 -1950's, photograph by Dan HerronTPO ROOFING ANODIZED ALUMINUM CANOPY FASCIA STUCCO SYSTEM AT SOFFIT 10 CANOPY SECTION SCALE: 1 1/2" = 1'-0" REPOINT MASONRY AS NECESSARY ANODIZED ALUMINUM WINDOW SYSTEM 117' - 0" LEVEL 2 CLEAN FACADE WITH PURIFIED WATER AT LOW PRESSURE, NATURAL BRUSH AS NEEDED. CLEANING TO BE PERFORMED BY QUALIFIED ARCHITECTURAL RESTORATION COMPANY 10 SK-01 100' - 0" L1 REPOINT MASONRY AS NECESSARY 117' - 0" LEVEL 2 CLEAN FACADE WITH PURIFIED WATER AT LOW PRESSURE, NATURAL BRUSH AS NEEDED. CLEANING TO BE PERFORMED BY QUALIFIED ARCHITECTURAL RESTORATION COMPANY REPLACE WITH INSULATED GLASS, EXISTING WOOD FRAME TO REMAIN 100' - 0" L1 08 WALL SECTION 2 SCALE: NTS 05 WALL SECTION 1 SCALE: NTS 04 WEST ELEVATION SCALE: NTS BLUMCRAFT ENTICE ENTRY SYSTEM WITH IG DOOR OPERATOR EXISTING EXTERIOR LIMESTONE 07 PROPOSED DOOR JAMB SCALE: 3" = 1'-0" EXTERIOR INTERIOR EXISTING WOOD FRAME TO REMAIN REPLACE WITH INSULATED GLASS REPLACE WOOD FRAME TO ACCOMMODATE INSULATED GLASS 01 01 01 ANODIZED ALUMINUM WINDOW SYSTEM - OTIIMA SERIES 38 C B " 6 - ' 1 2 A.1 A LINEAR WALL WASH LIGHTING LIGHT GREY TPO ROOFING C B " 6 - ' 1 2 A.1 A EXISTING WINDOW FRAME TO REMAIN ANODIZED NARROW STYLE DOUBLE DOORS C B " 6 - ' 1 2 A.1 A 09 DOOR AND WINDOW DETAILS SCALE: 12" = 1'-0" REF: 06 FIXED WINDOW - JAMB DETAIL SCALE: 3" = 1'-0" 03 PORTICO PLAN - 03 SCALE: NTS 02 PORTICO PLAN - 02 SCALE: NTS 01 PORTICO PLAN - 01 SCALE: NTS PRELIMINARY: NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION I N O T A R O T S E R S S E R G N O C 5 0 9 S R E N T R A P N E S L E N . X T , I N T S U A . E V A S S E R G N O C 5 0 9 Date 03.19.2025 Revisions Drawings and written material appearing herein constitute original and unpublished work of the architect and may not be duplicated, used, or disclosed without written consent of the architect. © 2019 NELSEN PARTNERS, INC. Project No. 23098 SK-01 EXTERIOR PRESERVATION LINE OF STRUCTURE LINE OF STRUCTURE BLOCKING NOTES PLAN GENERAL NOTES HEAD PLAN BASE LINE OF STRUCTURE METAL STUDS TO EXTEND TO STRUCTURE AS REQUIRED CEILING AS SCHEDULED 5/8" GYPSUM BOARD, (1) LAYER BOTH SIDES. PROVIDE CEMENT BACKER BOARD WHERE TILE OR STONE OCCURS, REFER TO INTERIOR ELEVATIONS FOR FINISH LOCATIONS METAL STUDS ACOUSTICAL BATT INSULATION REQIRED FOR STC RATING FINISH AS SCHEDULED BASE AS SCHEDULED REFER TO BASE DETAILS FOR VARIATIONS OF GYPSUM BOARD CONDITION WHERE OCCURS HEAD PLAN BASE CEILING AS SCHEDULED 5/8" GYPSUM BOARD (1) LAYER BOTH SIDES; PROVIDE CEMENT BACKER BOARD WHERE TILE OR STONE OCCURS, REFER TO INTERIOR ELEVATIONS FOR FINISH LOCATIONS ACOUSTIC BATT INSULATION REQUIRED FOR STC RATING METAL STUDS FINISH AS SCHEDULED BASE AS SCHEDULED REFER TO BASE DETAILS FOR VARIATIONS OF GYPSUM BOARD CONDITION WHERE OCCURS 10" WALL TYPE STUD SIZE WALL SIZE FIRE RATING UL DESIGN STC RATING H3 H6 3 5/8" 10 6" 14 1/4" - - - - - 62 WALL TYPE STUD SIZE WALL SIZE FIRE RATING UL DESIGN STC RATING C2 C3 C6 2 1/2" 3 3/4" 3 5/8" 4 7/8" 6" 7 1/4" - - - - - - 41-47 43-51 39-41 HEAD PLAN BASE CEILING AS SCHEDULED 5/8" GYPSUM BOARD; PROVIDE CEMENT BACKER BOARD WHERE TILE OR STONE OCCURS, REFER TO INTERIOR ELEVATIONS FOR FINISH LOCATIONS METAL STUD AS SCHEDULED FINISH AS SCHEDULED BASE AS SCHEDULED REFER TO BASE DETAILS FOR VARIATIONS OF GYPSUM BOARD CONDITION WHERE OCCURS WALL TYPE STUD SIZE WALL SIZE FIRE RATING UL DESIGN A0 A1 A2 A3 A6 7/8" 1 1/2" 1 5/8" 2 1/4" 2 1/2" 3 1/8" 3 5/8" 4 1/4" 6" 6 5/8" - - - - - - - - - - H PARTITION TYPE SCALE: 1 1/2" = 1'-0" REF: H / SK-02 C PARTITION TYPE SCALE: 1 1/2" = 1'-0" REF: C / SK-02 A PARTITION TYPE SCALE: 1 1/2" = 1'-0" REF: A / SK-02 1. WHERE WALL MOUNTED EQUIPMENT OR CABINETS OCCUR, G.C. SHALL PROVIDE IN WALL FIRE RETARDANT TREATED BLOCKING AT LOCATIONS DESIGNATED ON PLANS OR REQUIRED BY MFR.'S FOR MOUNTING. 2. G.C. SHALL PROVIDE IN WALL FIRE RETARDANT TREATED 2X BLOCKING AT ALL SPECIALTY EQUIPMENT LOCATIONS SUCH AS BUT NOT LIMITED TO GRAB BARS, MIRRORS, TOILET PAPER DISPENSERS, ETC. (REFER TO ENLARGED PLANS, ELEVATIONS AND TAS NOTES PAGE FOR ADDITIONAL LOCATION INFORMATION.) 3. BLOCKING MAY BE ACHIEVED BY ANY OF THE FOLLOWING METHODS: a. b. c. 2 X FIRE RETARDANT TREATED WOOD BLOCKING. 4" MINIMUM SHEET METAL BACKING PLATE(S). 1/2" FIRE RETARDANT TREATED CONTINUOUS PLYWOOD SHEATHING BEHIND GYPSUM SHEATHING. (NOTE: THIS CAN ONLY BE SUBSTITUTED AFTER CAREFUL CLEARANCE CONSIDERATION AND WITHOUT SIGNIFICANT COST ADDITIONS TO THE OWNER UNLESS REQUESTED SPECIFICALLY BY THE OWNER.) LINE OF STRUCTURE (I.E. DECK OR BEAM) J-RUNNER - SHORT LEG TOWARD FINISHED SIDE OF WALL CEILING AS SCHEDULED 5/8" GYPSUM BOARD (1) LAYER C-H STUDS 1" GYPSUM LINER PANEL FINISH AS SCHEDULED BASE AS SCHEDULED J-RUNNER - SHORT LEG TOWARD FINISHED SIDE OF WALL HEAD PLAN BASE WALL TYPE STUD SIZE WALL SIZE FIRE RATING UL DESIGN STC RATING S1 2 1/2" 3 1/8" 1 HOUR U415, SYSTEM A 39 S PARTITION TYPE SCALE: 1 1/2" = 1'-0" REF: S / SK-02 SCOPE OF WORK: INTERIOR PARTITIONS - REPLACE GYPSUM BOARD, TILE BACKER BOARD, AND ACOUSTIC INSULATION ONTO EXISTING FRAMING AS SCHEDULED. EXTERIOR WALLS - REPLACE GYPSUM BOARD AND INSTALL FULL BATT INSULATION AT ALL EXTERIOR CONDITIONS - COMPLETELY FILL CAVITY. 1. DIMENSIONS ARE TO FINISH FACE, CENTERLINE OF MULLION, CENTERLINE OF GLAZING, OR CENTERLINE OF COLUMN UNLESS NOTED OTHERWISE. 2. REFER TO ENLARGED PLANS FOR ADDITIONAL INFORMATION. 3. REFER TO SHEET A101 FOR ADDITIONAL INFORMATION REGARDING LIFE SAFETY REQUIREMENTS. 4. REFER TO SHEET A240 FOR MATERIALS SCHEDULE. 5. PAINT ALL EXISTING AND EXPOSED STEEL MEMBERS. REF FINISH SCHEDULE ON A240 6. GYPSUM BOARD SCOPE: GYPSUM BOARD IS INSTALLED AND FINISHED PER THE SPECIFICATIONS AT SPACES SCHEDULED TO RECEIVE FINISH. 7. ALL EXISTING EXTERIOR DOORS AND WINDOWS TO REMAIN. GYPSUM BOARD NOTES 1. INTERIOR GYPSUM BOARD: USE 5/8" TYPE X GYPSUM WALL BOARD (GWB) UNLESS OTHERWISE NOTED. 2. WHEN RUN TO METAL DECK, GWB SHALL BE HELD OFF OF FLUTES BY 3/8" AND VOID TO BE FILLED WITH ACOUSTICAL SEALANT. 3. USE GLASS-MAT INTERIOR GWB W/ FIBERGLASS MAT LAMINATED TO BOTH SIDES AT THE FOLLOWING LOCATIONS: ALL UNCONDITIONED SPACES. a. WITHIN 2'-0" HORIZONTALLY AND 4'-0" VERTICALLY OF b. JANITORS SINKS. 4. USE 5/8" THICK, TYPE X, DensShield TILE BACKER BEHIND TILE INSTALLATION AT NON- WET WALL LOCATIONS.USE 1/2" THICK Durock CEMENT BOARD AT THE FOLLOWING LOCATIONS: a. b. c. SHOWERS JANITORS SINK WET WALL LOCATIONS BEHIND TILE. 5. HOLD SHEATHING OFF FINISH FLOOR AND TOP STRUCTURE 3/8". FILL 3/8" VOID WITH ACOUSTICAL SEALANT AT ALL NON-FIRE RATED PARTITIONS. FILL 3/8" VOID WITH CONTINUOUS MINERAL FIRE RESISTIVE SEALANT AT ALL FIRE RATED PARTITIONS. EXISTING WINDOW TO REMAIN " 4 - ' 2 2 . F . I . V 01 A401 EXISTING GLASS ENCLOSURE TO REMAIN OFFICE 201 01 A550 EXISTING MILLWORK EXTEND WALL TO MEET NEW STAIR 3' - 6" T.O.W DN 201 " 2 / 1 6 - ' 4 ~ R L C FEC 114' - 0" (V.I.F.) EXISTING WINDOWS TO REMAIN C3 1 S 1 S C3 1 S OPEN OFFICE - WEST 202 EXISTING GLAZED WALL TO REMAIN BREAK OUT ROOM 207 EXISTING WINDOWS TO REMAIN 01 A401 C3 205A 205B S1 C3 EXISTING GUARDRAIL TO REMAIN. C3 1 S C3 1 S ROOF ACCESS ABV MTL LADDER 114' - 0" (V.I.F.) DN FEC 207 OPEN TO BELOW PRELIMINARY: NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION I N O T A R O T S E R S S E R G N O C 5 0 9 S R E N T R A P N E S L E N . X T , I N T S U A . E V A S S E R G N O C 5 0 9 02 L2 - FLOOR PLAN SCALE: 3/16" = 1'-0" REF: 02 / SK-02 PLAN NORTH Date 03.19.2025 PERMIT SET Revisions 2 ADDENDUM 1 03/03/2025 01 A550 UP NEW STAIR AND HANDRAILS EXISTING STRUCTURE EXISTING WINDOWS & DOOR TO REMAIN " 4 - ' 2 2 . F . I . V EX01 EXISTING MILLWORK BELOW STAIR LANDING EXISTING BEAM, ADJUST HEIGHT FOR NEW STAIR EXISTING HSS COLUMN LOBBY 103 100' - 0" EXISTING MILLWORK CONFERENCE ROOM 104 REFR. EXISTING MILLWORK CONFERENCE 105 EXISTING TRACK AT CEILING. ADD HANGERS TO STIFFEN DOOR TRACKS 01 A401 RECEPTION 101 EXISTING MILLWORK CORRIDOR 102 100' - 0" 5/8" / 12" 105 100' - 8" 01 A260 D A3 HC-RR 01 106 HC-RR-02 107 HC-RR-03 108 106 107 108 JANITOR 112 112 WH 111 LASER PRINTER WORK ROOM 114 RR-04 109 RR-05 110 109 110 DASHED LINE OF EXISTING STL BEAM ABV EXISTING HSS COLUMN EXISTING HSS COLUMN 5/8" / 12" 102' - 0" UP EXISTING MILLWORK BREAK ROOM 115 102' - 0" DASHED LINE OF SOFFIT ABOVE FEC REFR. EXISTING ENCLOSURE AT EXISTING OPENING 01 A401 EXISTING STRUCTURE 12' - 6" 6' - 1" SLOPED SURFACE LANDING 23' - 5 1/2" SLOPED SURFACE 01 L1 - FLOOR PLAN SCALE: 3/16" = 1'-0" REF: 01 / SK-02 PLAN NORTH EXISTING DOOR & GATE AT ALLEY TO REMAIN Drawings and written material appearing herein constitute original and unpublished work of the architect and may not be duplicated, used, or disclosed without written consent of the architect. © 2025 NELSEN PARTNERS, INC. Project No. 20-044.01 SK-02 FLOOR PLANS SKYLIGHT & ROOF ACCESS SCHEDULE TAG MANUFACTURER / MODEL SIZE GLAZING U-VALUE SHGC SK-1 SK-2 SK-3 SK-4 VELUX CFP + ISD 1093 200100 - V.I.F. TO EXISTING CURB 05 - TEMPERED LOW-E VELUX CFP + ISD 1093 120120 05 - TEMPERED LOW-E FAKRO DRF (ROOF ACCESS) 48" X 48" DU6 TRIPLE PANE LOW-E VELUX CFP + ISD 1093 060060 - V.I.F. TO EXISTING CURB 05 - TEMPERED LOW-E 0.30 0.30 0.30 0.30 0.42 0.42 0.42 0.42 ROOF PLAN NOTES: 1. SPRAY APPLIED THERMAL AND ACOUSTIC INSULATION AT UNDERSIDE OF ROOF STRUCTURE TO ACHIEVE A THERMAL VALUE OF R-12 THROUGHOUT. ROOF INSULATION ABOVE DECK SHALL BE R-25. 2. REPLACE TPO ROOFING MEMBRANE TO MEET WARRANTY REQUIREMENTS AND PRODUCE A WATERTIGHT ASSEMBLY. 3. ADD TAPERED POLYISOCYANURATE INSULATION CRICKETS AS REQUIRED TO DIRECT WATER TO DRAINS / GUTTERS. REPLACE DAMAGED MECHANICAL EQUIPMENT AND DUCTS IN KIND PROVIDE 42" HT GALV MTL GUARDRAIL AT ALONG THIS NORTH PARAPET WALL AT EXTENT SHOWN 75' - 1" 20' - 0" GUARDRAIL EXISTING SKYLIGHT TO REMAIN EXIST. SLOPE CRICKET AT SKYLIGHTS EXISTING SKYLIGHT TO REMAIN 01 A401 SK4 SK4 SK4 NEW TPO MEMBRANE ROOF OVER NEW R-25 RIGID INSULATION OVER EXISTING STRUCTURE SK1 SK1 NEW SKYLIGHT E P O L S . I T S X E E P O L S . I T S X E SK4 E P O L S . I T S X E E P O L S 01 A401 SK4 EXISTING SKYLIGHT TO REMAIN . I T S X E NEW SKYLIGHTS NEW SKYLIGHTS NEW SKYLIGHT 01 ROOF PLAN SCALE: 3/16" = 1'-0" REF: 01 / SK-03 PRELIMINARY: NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION I N O T A R O T S E R S S E R G N O C 5 0 9 S R E N T R A P N E S L E N . X T , I N T S U A . E V A S S E R G N O C 5 0 9 Date 03.19.2025 PERMIT SET Revisions Drawings and written material appearing herein constitute original and unpublished work of the architect and may not be duplicated, used, or disclosed without written consent of the architect. © 2025 NELSEN PARTNERS, INC. Project No. 20-044.01 SK-03 ROOF PLAN