Historic Landmark CommissionDec. 11, 2024

3 - 601 Colorado St - Package — original pdf

Backup
Thumbnail of the first page of the PDF
Page 1 of 6 pages

TXST O. HENRY HALL Austin | Dallas | San Antonio www.architexas.com 1023 Springdale Rd Building 11 Suite E Austin, Texas 78721 p 512.444.4220 Security Gates Austin, Texas AREA MAP OWNER Texas State University Physical Plant Complex 151-2 E. Sessom Dr San Marcos, Texas 78666 Email: gfr11@txstate.edu Office: 512.245.2824 ARCHITECT ARCHITEXAS Architecture, Planning, and Historic Preservation Inc 1023 Springdale Rd., Bldg 11, Suite E Austin, TX 78721 Email: sfrocheur@architexas.com Office: 512.444.4220 LOCATION MAP 3. Dimension of original materials: Dimensions indicated in Construction Documents for existing materials are approximate and are to be field verified prior to submittal of shop drawings. Match exact sizes and profiles of existing elements, unless noted otherwise. 6. Photographs: A. Photographs of existing building conditions are included on portions of these drawings. Information contained on these photographs is provided for the convenience of the Contractor. Existing conditions may vary from what these photographs show. It shall be the responsibility of the Contractor to verify field conditions prior to the time of the bid and alert the Architect to any discrepancies between the existing conditions and the photographs. 7. Exterior: A. Existing construction shown to remain shall not be damaged during the demolition process. Provide temporary protection as necessary. If surfaces of wall are damaged, damaged areas shall be repaired with masonry to match existing and restore the full structural capacity of the walls. GENERAL NOTES 1. Existing Conditions: A. Information contained on these drawings with regard to existing conditions for construction in no way releases the Contractor from the responsibility for verifying completely all field conditions relating to and affecting the execution of the work, as described in these Contract Documents. Cease work, notify Architect, and await instructions if materials or conditions encountered at the site are not as indicated by the Contract Documents. Field verification of existing conditions relating to specific portions of the work shall be undertaken in advance to allow for the timely identification of existing conditions that may effect the scheduled installation of new work as designed and detailed, and to avoid undue and unreasonable delays to the project should such conditions be discovered. Timely identifications of such conditions shall provide for a reasonable period of time during which the Architect will evaluate the conditions and make recommendations for accommodating new work. Assist the Architect in making their evaluations and recommendations by providing in a timely manner, at no additional cost to the Owner, accurate and complete drawings, sketches, and photographs sufficient to clearly describe discrepancies, conflicts, and concealed or otherwise unanticipated existing conditions affecting new construction. Assist the Architect by providing in a timely manner prepared solutions to unanticipated existing conditions. The Architect has endeavored to identify as completely as possible in the drawings and specifications existing items that are required to be removed or otherwise demolished so as to allow the execution of new work. This information is provided for the convenience of the Contractor, and is in no way intended to mean that demolition is limited only to those items specifically identified. Execute demolition work as required to allow the execution of new work. Areas and items indicating limits of work and lines of demarcation are shown for the convenience of the Contractor, and are not to be taken literally. Actual contract limits are to be determined prior to bid openings by field verification. B. C. D. E. 2. Blocking and Framing Some general assumptions have been made on existing blocking, framing, and existing masonry profiles where conditions have not been uncovered. Re-secure existing blocking as necessary and provide new blocking as needed at roof edges, parapets, penetrations, and elsewhere where shown on the drawings. INDEX OF DRAWINGS ARCHITECTURAL A-0.00 A-0.01 A-0.02 A-2.01 A-3.01 A-5.01 COVER SHEET PHOTOS PHOTOS PLAN ELEVATION DETAILS HISTORIC DESIGNATIONS NRHD: CONTRIBUTING RESOURCE TO THE SIXTH STREET HISTORIC DISTRICT RTHL: RECORDED TEXAS HISTORIC LANDMARK TXST O. HENRY HALL SECURITY GATES 601 Colorado St. Austin, Texas 78701 COPYRIGHT The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing. Any errors or omissions shall be reported to Architexas without delay. The Copyrights to all designs and drawings are the property of Architexas. Reproduction or use for any purpose other than that authorized by Architexas is forbidden. REVISION HISTORY NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION SUSAN FROCHEUR, 12/11/24 SYMBOLS X/A.X.00 DETAIL KEY X/A.X.00 DETAIL KEY ELEVATION KEY WALL SECTION DETAIL SECTION EARTH/COMPACT FILL ROUGH WOOD GRAVEL FILL CONCRETE HOLLOW CLAY TILE BLOCKING FINISH WOOD PLYWOOD MASONRY RIGID INSULATION SPLIT FACE CMU THERMAL BATT INSULATION GLASS ALUMINUM STEEL SHEET METAL NEW WALLS, U.N.O. ACOUSTIC BATT INSULATION SPRAYED INSULATION SPRAYED FIRE INSULATION CERAMIC TILE GYPSUM BOARD METAL LATH AND PLASTER ABBREVIATIONS ± O A/C ACM AHU CABS. CLG. CONC. DN. ELEV. EQ. EQUIP. EXIST. FIXT. FLR. F.R. GYP. GWB HIST. MECH. MISC. MTL. OC ORIG. PTD. QTR. REF. REQ'D STRUCT. T.B.D. THK. TYP. U.N.O VIF W/ WD. PLUS/MINUS DIAMETER AIR CONDITIONER ASBESTOS CONTAINING MATERIAL AIR HANDLING UNIT CABINETS CEILING CONCRETE DOWN ELEVATOR EQUAL EQUIPMENT EXISTING FIXTURES FLOOR FIRE RATED GYPSUM GYPSUM WALL BOARD HISTORIC MECHANICAL MISCELLANEOUS METAL ON CENTER ORIGINAL PAINTED QUARTER REFERENCE REQUIRED STRUCTURAL TO BE DETERMINED THICK TYPICAL UNLESS OTHERWISE NOTED VERIFY IN FIELD WITH WOOD NOTE: CONTRACTOR SHALL VERIFY WITH ARCHITECT FOR ANY ABBREVIATION NOT LISTED. Sheet Name Cover Sheet Architexas No. 2431 Date December 11th, 2024 Sheet Number A–0.00 ORIGINAL FENCE, REF. PHOTO 3 ORIGINAL FENCE, REF. PHOTO 2 PHOTO 1: O. HENRY HALL, LATE 1880s. IMAGE COURTESY OF THE AUSTIN HISTORY CENTER " 0 - 4 ' " 0 - 4 ' PHOTO 2: EXISTING 1880S ORIGINAL FENCING ALONG EAST PROPERTY LINE PHOTO 3: EXISTING 1880S ORIGINAL FENCING @ NORTHEAST CORNER OF SITE Austin | Dallas | San Antonio www.architexas.com 1023 Springdale Rd Building 11 Suite E Austin, Texas 78721 p 512.444.4220 TXST O. HENRY HALL SECURITY GATES 601 Colorado St. Austin, Texas 78701 COPYRIGHT The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing. Any errors or omissions shall be reported to Architexas without delay. The Copyrights to all designs and drawings are the property of Architexas. Reproduction or use for any purpose other than that authorized by Architexas is forbidden. REVISION HISTORY NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION SUSAN FROCHEUR, 12/11/24 Architexas No. 2431 Date December 11th, 2024 Sheet Name Photos Sheet Number A–0.01 PHOTO 4: EXISTING 2018 FENCE AT 6TH STREET PHOTO 5: EXISTING 2018 GATE AT 6TH STREET " 4 / 1 8 - 5 ' ORIGINAL TILE FLOORING 1971 GRANITE STEPS & LANDING Austin | Dallas | San Antonio www.architexas.com 1023 Springdale Rd Building 11 Suite E Austin, Texas 78721 p 512.444.4220 " 4 / 1 8 - 5 ' TXST O. HENRY HALL SECURITY GATES 601 Colorado St. Austin, Texas 78701 COPYRIGHT The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing. Any errors or omissions shall be reported to Architexas without delay. The Copyrights to all designs and drawings are the property of Architexas. Reproduction or use for any purpose other than that authorized by Architexas is forbidden. REVISION HISTORY NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION SUSAN FROCHEUR, 12/11/24 Architexas No. 2431 Date December 11th, 2024 Sheet Name Photos Sheet Number A–0.02 PHOTO 6: WEST ENTRY PORCH AT COLORADO STREET, LOOKING NORTHEAST PHOTO 7: WEST ENTRY PORCH AT COLORADO STREET, LOOKING EAST PHOTO 8: WEST ENTRY PORCH AT COLORADO STREET, LOOKING NORTH ALIGN CENTER OF GATE WITH CENTER OF TILE " 8 / 1 " 3 " 4 / 3 0 - 3 ' " 3 " 0 1 - 3 ± ' " 3 " 8 / 1 " 8 - 7 ± ' 3" BENT MTL. PLATE COPE TO EXIST. WALL 5/A5.01 ±7" . 1 0 3 A / 1 4/A5.01 3" SQUARE PTD. MTL. POST REMOVE EXIST. FLOOR TILE, PROVIDE 3 8" THK. PTD. MTL. PLATE, SHAPE TO MATCH REMOVED TILE 3" BENT MTL. PLATE SCRIBE TO EXIST. WALL 3/A5.01 EXIST. HANDRAIL TO REMAIN Partial Floor Plan - West Porch South Gate, North Gate Sim 1 Scale: 1/2" = 1'-0" N PLAN NORTH EXIST. TILE FLOORING Austin | Dallas | San Antonio www.architexas.com 1023 Springdale Rd Building 11 Suite E Austin, Texas 78721 p 512.444.4220 TXST O. HENRY HALL SECURITY GATES 601 Colorado St. Austin, Texas 78701 COPYRIGHT The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing. Any errors or omissions shall be reported to Architexas without delay. The Copyrights to all designs and drawings are the property of Architexas. Reproduction or use for any purpose other than that authorized by Architexas is forbidden. REVISION HISTORY NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION SUSAN FROCHEUR, 12/11/24 Architexas No. 2431 Date December 11th, 2024 Sheet Name Floor Plan Sheet Number A–2.01 3" BENT MTL. PLATE COPE TO EXIST. WALL 3'-0 3/4" 2'-8 5/8" . 1 0 5 A / 1 8" 4" 4" 3" SQUARE PTD. MTL. POST 3" BENT MTL. PLATE COPE TO EXIST. WALL POINTED MEMBERS TURNED ON DIAMOND, TYP. " 4 / 1 8 - 5 ' EXIST. HANDRAIL TO REMAIN, SHOWN HIDDEN FOR CLARITY 2/A5.01 3'-3 7/8" . X A M " 4 Gate Elevation South Gate, North Gate Sim. 1 Scale: 1/2" = 1'-0" Austin | Dallas | San Antonio www.architexas.com 1023 Springdale Rd Building 11 Suite E Austin, Texas 78721 p 512.444.4220 TXST O. HENRY HALL SECURITY GATES 601 Colorado St. Austin, Texas 78701 COPYRIGHT The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing. Any errors or omissions shall be reported to Architexas without delay. The Copyrights to all designs and drawings are the property of Architexas. Reproduction or use for any purpose other than that authorized by Architexas is forbidden. REVISION HISTORY NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION SUSAN FROCHEUR, 12/11/24 Architexas No. 2431 Date December 11th, 2024 Sheet Name Elevation Sheet Number A–3.01 . I N M " 4 " 8 / 1 . I N M " 3 EXIST. WALL SHIM PTD. MTL. TUBE 3" BENT MTL. PLATE COPE TO EXIST. WALL FLATHEAD COUNTERSUNK SCREW 1 2" DIA., RODS IN HILTI-200 ADHESIVE ANCHORS, BEYOND 7" X 1 1 BEYOND 2" BARREL HINGE, SECURITY GATE EXIST. WALL SHIM PTD. MTL. TUBE 3" BENT MTL. PLATE COPE TO EXIST. WALL FASTEN TO STRUCT. W/ 1 2" DIA. RODS IN HILTI-200 ADHESIVE ANCHORS; 4" MIN. EMBED INTO STRUCT. 7" X 1 1 BEYOND 2" BARREL HINGE, 3/8" JOINT, FILL W/ BACKER ROD & SEALANT 3" SQUARE PTD. MTL. POST, WELD TO PLATE SECURITY GATE 3" 5 Wall Bracket Detail Scale: 3" = 1'-0" 3" 5 Wall Bracket Detail Scale: 3" = 1'-0" " 2 / 1 " 4 / 3 9 - 5 ' 2 1/2" DIA. ADHESIVE ANCHOR, TYP., REF. DET. 2 3 8" THK. MTL. PLATE, PAINT TO MATCH COLOR OF EXIST. TILE FENCE FASTEN TO STRUCT. W/ 1 2" DIA. RODS IN HILTI-200 ADHESIVE ANCHORS; 4" MIN. EMBED INTO STRUCT. 3" BENT MTL. PLATE COPE TO EXIST. WALL PTD. MTL. TUBE SHIM EXIST. WALL 4 Post Base Plan Detail Scale: 3" = 1'-0" 3" " 3 . I N M " 4 " 8 / 1 . I N M " 8 / 1 . I N M " 3 " 2 / 1 3" " 2 / 1 1 1/2" EXISTING CONSTRUCTION Austin | Dallas | San Antonio www.architexas.com 1023 Springdale Rd Building 11 Suite E Austin, Texas 78721 p 512.444.4220 LEGEND " 2 / 1 " 1 " 2 / 1 " 2 / 1 1 " 2 / 1 3 " 4 / 1 2 1/2"X1 3/4" PTD. MTL. HORIZONTAL MEMBERS 5/8" PTD. MTL. VERTICAL MEMBERS, POINTED MEMBERS TURNED ON DIAMOND, TYP. 3" SQUARE PTD. MTL. POST, BEYOND " 4 / 1 4 - 5 ' " 4 / 3 0 1 - 3 ' " 4 / 3 7 " 2 / 1 4 " 5 . X A M " 4 TXST O. HENRY HALL SECURITY GATES 601 Colorado St. Austin, Texas 78701 COPYRIGHT The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing. Any errors or omissions shall be reported to Architexas without delay. The Copyrights to all designs and drawings are the property of Architexas. Reproduction or use for any purpose other than that authorized by Architexas is forbidden. REVISION HISTORY NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION SUSAN FROCHEUR, 12/11/24 Architexas No. 2431 Date December 11th, 2024 Sheet Name Details Sheet Number A–5.01 3 16" THK. PTD. MTL. PLATE, WELD TO POST, GRIND WELD SMOOTH 5/8" PTD. MTL. VERTICAL MEMBERS, POINTED MEMBERS TURNED ON DIAMOND, TYP. SECURITY GATE, 1 1/2"X1 3/4" PTD. MTL. HORIZONTAL MEMBERS 2"X 1 3 4" PTD. MTL. FRAME FLATHEAD COUNTERSUNK SCREW 3" SQUARE PTD. MTL. POST WELD TO PLATE 3/8" JOINT, FILL W/ BACKER ROD & SEALANT 3 8" THK. PTD. MTL. PLATE SET WITH NON-SHRINK GROUT LEVEL W/ EXIST. TILE. FASTEN TO STRUCT. W/ MIN. 3, 1 2" DIA., RODS IN HILTI-200 ADHESIVE ANCHORS; 4" MIN. EMBED INTO STRUCT. " 4 OVERSIZE HOLE; THREADED ROD FLUSH W/ TOP OF PLATE; PUDDLE WELD ANCHOR TO PLATE EXIST. CONC. STRUCT. EXIST. TILE FLOORING 3 Wall Bracket Detail @ Column Scale: 3" = 1'-0" 2 Post Base Section Detail Scale: 3" = 1'-0" 1 Fence Section Detail Scale: 1 1/2" = 1'-0"