ROOF: GENERAL NOTES 1. CONTRACTOR SHALL COORDINATE ALL ROOF PENETRATIONS WITH THE MECHANICAL AND PLUMBING DRAWINGS. 2. ROOFTOP EQUIPMENT SHALL BE LOCATED 10’-0” OR GREATER FROM THE FURTHEST EQUIPMENT PROJECTION TO THE ROOF EDGE TO THE GREATEST EXTENT POSSIBLE. WHERE CONSTRUCTION CONDITIONS DO NOT ALLOW FOR 10'-0" OR GREATER CLEARANCE, ROOFTOP GUARDS SHALL BE PROVIDED. 3. ALL MATERIALS WITHIN A SYSTEM SHALL BE SINGLE-SOURCED TO THE GREATEST EXTENT POSSIBLE WITH THE INTENT OF OBTAINING THE MOST INCLUSIVE PRODUCT/SYSTEM WARRANTY. 4. ALL FLAT ROOF SLOPES SHALL BE TAPERED 1/4":12 AS SHOWN ON PLAN AND SHALL MAINTAIN THE MINUMUM THICKNESS OF RIGID INSULATION AS INDICATED ON ROOF ASSEMBLY TYPES. 5. ALL ROOF DRAINS SHALL BE FURNISHED WITH PVC DRAIN CAGE. 6. EAVE-MOUNTED ROOF LEADERS SHALL BE CONNECTED TO SUB-SURFACE DRAINAGE. 7. ALL MATERIALS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS AND DETAILS. WHERE NO SPECIFIC DETAIL IS SHOWN WITHIN THESE DRAWINGS, PROVIDE MANUFACTURER'S STANDARD DETAIL, INCLUDING ALL ACCESSORIES. 8. NOTE: PROVIDE FULLY ADHERED ICE AND WATER SHIELD BY W.R. GRACE EXTENDING FROM THE LOWEST EDGES OF ALL ROOF SURFACES (EAVE EDGE) TO A POINT AT LEAST 36" BEYOND THE EXTERIOR FACE OF FRAMING AND 24" MIN. ON EACH SIDE OF ROOF PLANE INTERSECTIONS, TYP. EXTEND UP WALLS 18" AT ROOF/WALL INTERSECTIONS. PROVIDE ICE AND WATER SHIELD OVER ENTIRE ROOF AREA OVER EXTERIOR OR UNCONDITIONED SPACE 1 A305 2 A305 1 A306 2 A306 1 A204 1 A307 2 A307 1 A308 1/2" / 12" 1/2" / 12" 1/2" / 12" RD 1/2" / 12" RD 1/4" / 12" 1/2" / 12" RD 1/2" / 12" " 2 1 / " 4 / 1 " 2 1 / " 4 / 1 RD MEMBRANE ROOFING MEMBRANE ROOFING BELOW ROOF DECK 577' - 3 3/4" 1/2" / 12" 1/2" / 12" 1/2" / 12" RD 1/4" / 12" MEMBRANE ROOFING BELOW ROOF DECK 1/2" / 12" RD 1/2" / 12" 1/2" / 12" RD 1/2" / 12" MEMBRANE ROOFING 1/4" / 12" COURTYARD BELOW ROOF TOP PERGULA 1/4" / 12" 1/4" / 12" MEMBRANE ROOFING 1/2" / 12" RD 1/2" / 12" 1/2" / 12" RD 1/2" / 12" 1/2" / 12" DN MEMBRANE ROOFING 1/4" / 12" " 2 1 / " 2 / 1 RD " 2 1 / " 2 / 1 1/2" / 12" 1/2" / 12" " 2 1 / " 2 / 1 RD " 2 1 / " 2 / 1 " 2 1 / " 2 / 1 RD " 2 1 / " 2 / 1 1/4" / 12" RD 1/4" / 12" MEMBRANE ROOFING 1/4" / 12" DECK BELOW 1 A305 2 A305 1 A306 2 A306 1 A203 1 A307 2 A307 1 A308 1 A304 1 A303 1 A202 1 A302 1 A301 1 ROOF PLAN 1/4" = 1'-0" USE OF ARCHITECTS DOCUMENTS: THESE DOCUMENTS PREPARED BY THE ARCHITECT ARE INSTRUMENTS OF SERVICE FOR USE SOLELY WITH RESPECT TO THIS PROJECT, AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS INCLUDING THE COPYRIGHT(S). THE OWNER SHALL NOT REUSE OR PERMIT THE REUSE OF THESE DOCUMENTS INCLUDING ANY DESIGN & CONSTRUCTION DEVELOPMENT, CHANGES OR ALTERATIONS TO THESE DOCUMENTS, WITHOUT THE WRITTEN ACKNOWLEDGEMENT AND AUTHORIZATION OF THE ARCHITECT OWNER : FERGIE TIME LLC 2407 S.CONGRESS AVE., STE E-128 AUSTIN, TX 78704 512.426.1039 Consultant Logo GENERAL CONTRACTOR : FERGIE TIME LLC 2407 S.CONGRESS AVE., STE E-128 AUSTIN, TX 78704 512.426.1039 STRUCTURAL ENGINEER : SEC SOLUTIONS LLC MARCOS E. DEQUEIROGA, P.E. 1775 CR 279 SUITE D101 LIBERTY HILL, TX 78642 512.785.8446 1703 NEWNING AVE. 1703 NEWNING AVE. AUSTIN, TX 78704 No. Description Date PROGRESS: PERMIT DRAWINGS CONSTRUCTION DOCUMENTS Project Number 2402 Drawn by RV / RK Checked by BB Date 07.12.24 22x34 SHEET = SCALE AS NOTED 11x17 SHEET = 1/2 SCALE AS NOTED ROOF PLAN A121 7/12/2024 3:29:33 PM 1 A304 1 A303 2 A202 1 A302 1 A301