Historic Landmark CommissionJuly 3, 2024

23.2 - 4704 S Congress Bldg 15 - site plan — original pdf

Backup
Thumbnail of the first page of the PDF
Page 1 of 1 page

16976 1/4 CRZ 1/2 CRZ CRZ 19'-0" 9 ' - 6 " THIS PORTION OF THE SITE SHALL NOT BE USED FOR OCCUPANCY OR SEATING 16977 1/4 CRZ 1/2 CRZ CRZ EXISTING PAVILION 1,240 SF LIMIT OF CONSTRUCTION THIS PORTION OF THE SITE AND ALL UNUSED AREAS ARE NOT FOR PARKING NEW ACCESSIBLE PAVING 60 SF 40'-6" SEATING AREA 900 SF 29'-6" 2 5 ' - 0 " 1 A D A S p a c e 4 S p a c e s ( 8 . 5 ' x 1 7 . 5 " ) 5 C o m p a c t S p a c e s ( 7 . 5 ' x 1 5 ' ) 7 S p a c e s ( 8 . 5 ' x 1 7 . 5 ' ) NEW ENTRY PORCH NEW ADA RAMP H T G N E L E 8'- 6 " S O 7 A L H T O 2 9 5'-4" T NEW RESTROOMS 240 SF " 0 1 - ' 9 7 RELOCATED COTTAGE FOR RESTAURANT 578 SF FUTURE GREASE INTERCEPTOR PER MEP PLANS 33'-6" 16983 1/4 CRZ 1/2 CRZ CRZ 16982 1/4 CRZ 1/2 CRZ CRZ TO SANDRA ST. 16981 1/4 CRZ 1/2 CRZ EXISTING WATER SPIGOT PROPOSED NEW 6" DIAMETER SDR-26 WASTEWATER EXTENSION @ 2% EXISTING 6" PVC WASTE LINE TO REMAIN INDUSTRIAL WASTE SAMPLING PORT PER COA STANDARD NO.520-AW-01C 02/27/2024 SCALE: 1" = 20'-0" 0 5 10 20 CRZ 90 16980 1/4 CRZ 1/2 CRZ CRZ 16979 1/4 CRZ 1/2 CRZ CRZ 16978 1/4 CRZ 1/2 CRZ W CRZ 5604 S. CONGRESS AVE PROPERTY LINE SoCo Container Restaurant 5604 S. Congress Avenue Site Plan " 0 - ' 5 2 NEW FIRE LANE STRIPING S S E R G N O C . S RELOCATED COTTAGE (TEMPORARY STRUCTURE) 578 SF PROPOSED NEW 1" WATER LINE EXTENSION EXISTING 1" WATER LINE TO REMAIN EXISTING WATER METER PARKING CALCULATIONS RESTAURANT (PROPOSED).......................................................... PAVILION (EXISTING)....................................................................... RESTROOMS (PROPOSED)............................................................ TOTAL SF....................................................................................... 578 SF 900 SF 240 SF 1,718 SF PARKING PROVIDED ................................................................ 11 SPOTS TREE TABLE NO. SPECIES TRUNK DIAMETER 16976 HACKBERRY.............................................18" 16977 HACKBERRY...............................................9" 16978 HACKBERRY.............................................15" 16979 HACKBERRY....................18"/15" (25.5 CRZ) 16980 HACKBERRY..............................................18" 16981 CHINABERRY.............................................15" 16982 CATALPA....................................................13" 16983 HACKBERRY..............................................10" LEGEND PERCEIVED LINE OF EXISTING IMPERVIOUS COVER (12,941 SF) AREA TO BE RE-VEGETATED (5,621 SF) NOT FOR OCCUPANCY, NOT FOR SEATING NEW PAVING OR FLATWORK (60 SF) FOR ACCESSIBILITY IMPROVEMENTS EXISTING PAVING (1,045 SF) EXISTING GRAVEL TO BE PAVED AS MAINTENANCE ( 4,602 SF) ADA ACCESSSIBLE PATH FROM PARKING TO SEATING, RESTAURANT, RESTROOMS. PATH SHALL NOT EXCEED 5% IN RUNNING SLOPE AND 2% CROSS SLOPE. 36" MIN. WIDTH NEW IMPERVIOUS COVER AREA NEW ADA IMPROVEMENTS SQUARE FEET ADA PARKING......................................................................... TOTAL..................................................................................................... TOTAL AFTER ADA EXEMPTION........................................................... 60 SF 60 SF 0 SF NEW CONSTRUCTION AREAS AREA SQUARE FEET RESTAURANT........................................................................................ RESTROOMS........................................................................................... NEW PAVING/ FLATWORK........................................................................ TOTAL....................................................................................................... +ADA IMPROVEMENTS .......................................................................... 578 SF 240 SF 150 SF 968 SF 147SF Clayton Little, AIA TX#15170 INSTALL NEWINDUSTRIAL WASTE SAMPLING PORT PER COA STANDARD NO.520-AW-01C03/21/2024Olivia JimenezIndustrial WasteMarch 29, 2024Industrial Waste (IW) Site Plan Exemption (SPE) approvalonly - does not cover any other disciplines. Any changes to this sheet will require a new IW approvalstamp. This stamp does not imply approval of any designelements within the building footprint. Customer must stillmeet requirements for Commercial Plan Review, ifapplicable.10'-0"10' BL10' BL