22.1 - 5304 Western Hills - HLC Revisions — original pdf
Backup
PRELIMINARY NOT FOR CONSTRUCTION This drawing is not to be used for regulatory approval, permitting, or construction purposes. ISSUED DATE 03/22/2024 PROJECT NUMBER 2303 DD PRICING DEMO LEGEND EXISTING FRAMING TO REMAIN EXISTING CONSTRUCTION TO BE REMOVED DEMOLITION NOTES 1. 2. 3. 4. 5. 6. 7. 8. 9. ALL EXISTING COMPONENTS TO REMAIN ARE TO BE PROTECTED DURING DEMOLITION AND CONSTRUCTION BY THE GENERAL CONTRACTOR (GC). ANY DAMAGED MATERIAL IS TO BE REPAIRED, REPLACED, OR REBUILT IN A MANNER ACCEPTABLE TO THE OWNER AND ARCHITECT. THE GC IS RESPONSIBLE FOR ALL NECESSARY DEMOLITION OF THE BUILDING SYSTEMS, AND PATCHING OR REPAIR OF EXISTING BUILDING FINISHES/ SITE FEATURES AFFECTED BY NEW CONSTRUCTION. DAMAGES TO THE PROPERTY OF THE OWNER SHALL BE REPAIRED OR PAID FOR BY THE GC. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO, DAMAGE TO THE BUILDING GROUNDS, PLANTINGS, WALLS, PAVEMENT, VEHICLES, UTILITIES, FINISHES, FURNISHINGS, ETC. PATCH, REPAIR, AND PREPARE ALL SURFACES AS REQUIRED TO ACCOMMODATE NEW FINISHES INDICATED. CONTRACTOR TO BRACE/SHORE EXISTING CONSTRUCTION TO REMAIN. ALL APPLIANCES AND PLUMBING FIXTURES TO BE SALVAGED FOR REUSE OR SALE, COORDINATE WITH OWNER. ALL CASEWORK TO BE REMOVED TO BE SALVAGED FOR REUSE OR DONATION, COORDINATE WITH OWNER. ALL STONE, WOOD CLADDING TO BE SALVAGED, COORDINATE WITH OWNER. ALL DIMENSIONS ARE TO FACE OF EXISTING WALL FINISH U.N.O. AREA OF ROOF TO BE DEMOLISHED FOR NEW SKYLIGHT, RE: SCHEDULE REMOVE EXISTING ROOFING CLERESTORY WINDOWS AT ROOF POP-UP TO BE DEMOLISHED REMOVE EXISTING ROOFING COLUMNS TO BE DEMOLISHED STAIRS CAN REMAIN (TO BE CONCEALED BY NEW CONSTRUCTION) REMOVE PLANTER EXISTING STAIR TO BE REMOVED EXISTING SIDEWALK TO BE REMOVED EXISTING SINGLE PANE WINDOWS TO BE REMOVED. EXISTING MANUFACTURED WINDOWS TO BE REMOVED, TYP REMOVE PLUMBING FIXTURES, TYP. REMOVE AND REPLACE SKYLIGHT AREA OF ROOF TO BE DEMOLISHED FOR NEW SKYLIGHT KITCHEN TO BE DEMOLISHED REMOVE MILLWORK EXISTING RAILING TO REMAIN K R O W T A L F F O A E R A I N A M E R O T REMOVE FLATWORK AROUND PERIMETER OF BUILDING, U.N.O REMOVE STAIR POCKET DOOR AND TRANSOM WINDOW TO BE REMOVED WOOD PANELING TO BE REMOVED MILLWORK TO BE REMAIN PLANTER TO REMAIN STAIRS CAN REMAIN (TO BE CONCEALED BY NEW CONSTRUCTION) REMOVE MILLWORK AREA OF FLATWORK TO REMAIN AREA OF FLATWORK TO REMAIN REMOVE FLATWORK REMOVE STAIR REMOVE RAILING WHERE INDICATED, TYP. REMOVE FLATWORK AROUND PERIMETER OF BUILDING, U.N.O. EXISTING FIREBOX TO BE DEMOLISHED, CHIMNEY TO REMAIN REMOVE RAILING WHERE INDICATED, TYP. 2 ROOF PLAN - DEMOLITION 1/8" = 1'-0" 1 FIRST FLOOR PLAN - DEMOLITION 1/8" = 1'-0" TRUE NORTH PROJECT NORTH E C N E D I S E R S L L I H N R E T S E W I E V R D S L L I H N R E T S E W 4 0 3 5 1 3 7 8 7 X T , N I T S U A D101 DEMOLITION FLOOR PLANS M P 5 5 : 4 2 : 4 4 2 0 2 / 2 2 / 3 | | r r e u t c e t i h c A d a w t u O © r A B C 1 A303 1 A301 D 2 A303 E 2 A301 H +/-12'-5 1/4" V.I.F. +/-13'-9 3/4" V.I.F. +/-25'-7 1/2" V.I.F. +/-47'-6" V.I.F. 2 / A202 XC 4 / A203 CARPORT 134 3 / A203 832' - 11 5/8" 1.34C 1.34B 1.34A XA CLOSET 136 XA CLOSET 135 W/D SLEEPER SOFA, RE: INTERIORS 10 A405 1.33A 1 / 2 " 17 3 3 . 1 833' - 0 1/4" ENTRY 133 IA B 3 3 . 1 IA NEW STAIRS AT EXISTING LOCATION, RE: LANDSCAPE NEW SIDEWALK, RE: LANDSCAPE " 4 / 1 3 - ' 5 XA OFFICE 131 EXISTING STAIR; NEW WOOD TREAD AND RISER 2 / A203 " 6 UP 1.30 H T A B E C I F F O 2 " 0 3 1 FRONT PORCH 100 1 A403 1.01B 1.01C 1.01 2 3 / 8 " XA 829' - 5 5/8" MECH N. 102 IB IB PANTRY 127 1 3 . 1 9 2 . 1 7 2 . 1 1 1/4" HALL 1 128 8 2 . 1 829' - 5 5/8" A 8 2 . 1 LAUNDRY 129 1 / A203 EXISTING STAIR; NEW WOOD TREAD AND RISER 1 A404 W D 1.26C 1.26B 1.26A XA UP 1 0 2 A / 2 1 / A203 EXISTING STAIR; NEW WOOD RISER AND TREAD PRIMARY SHOWER 107 PRIMARY WC 106 9'-8 1/8" 1.05A PRIMARY BATH 105 7 0 1 . 3" A 1 3 . 1 B 1 3 . 1 C 1 3 . 1 A 0 3 . 1 B 0 3 . 1 2 0 . 1 3 0 1 . " 8 / 1 E P O L S I N A R D O T " 1 - ' 5 UP POWDER 103 IB IA IA BAR 5'-7 7/8" 6'-0 3/4" I G N V L E H S IA EQ IA 1'-3 1/2" 6 0 1 . FOYER 101 IA SKYLIGHT ABOVE 827' - 4 7/8" EQ A 8 0 1 . 4 0 1 . T E S O L C 4 0 1 4'-4" 1.05 1.09 PRIMARY CLOSET 109 NEW DOOR IN EXISTING OPENING GUEST BATH 122 14 A406 1.23A 1.22 1.21B Q E Q E FD 1.22B 4" FITNESS 123 SKYLIGHT ABOVE GUEST BED 121 1.22A SKYLIGHT ABOVE 1.20 3 2 1 . LINEN 124 1.24 3'-0 5/8" MECH S. 120 " 4 / 3 4 1.25 FITNESS CLOSET 125 IA A407 2 1 HALL 2 114 CLOSET 141 1.41 1.39A 1.19 LINEN 140 1.39B SKYLIGHT ABOVE 5 1 1 . BEE'S ENTRY 139 DW SHELF ABOVE KITCHEN 126 " 0 - ' 2 ISLAND SKYLIGHT ABOVE NEW WOOD FLOORING THROUGHOUT BOOKSHELF; ALIGN LINE OF CEILING ABOVE SHOWN DASHED BEE'S CLOSET 119 1.18 CLOSET 118 BUILT-IN DESK ELECTRICAL PANEL DINING 112 FAMILY 113 PLAYROOM 115 BEE'S BEDROOM 117 XB A F O S N I - T L U B I PLAN LEGEND EXISTING CONSTRUCTION TO REMAIN NEW CONSTRUCTION WOOD FLOORING WOOD DECKING TILE FLOORING CONCRETE FLOORING CARPET SMOKE/CO DETECTOR GENERAL NOTES 1. 2. 3. 4. 5. 6. 7. 8. 9. SEE ARCHITECTURAL FOUNDATION PLAN FOR ALL DIMENSIONS PERTAINING TO CONCRETE SLAB, CONCRETE WALLS, STEEL COLUMNS, AND STRUCTURAL GRID LINES. EXTERIOR WALL DIMENSIONS ARE GENERALLY BASED ON THE ACTUAL FOUNDATION AS POURED AND NOT THE DIMENSIONS ON THE FLOOR PLANS OR THE FOUNDATION PLAN. CONCRACTOR IS TO NOTIFY ARCHITECT IN THE EVENT OF INCONSISTENCIES GREATER THAN 1" BETWEEN THE FOUNDATION PLAN DIMS AND THE ACTUAL FOUNDATION. WHEN DIMENSIONAL DISCREPENCIES ARE LESS THAN 1" EXTERIOR FRAME WALLS ARE TO BE PLACED PER NOTE 3 BELOW. EXTERIOR FACE OF FACE OF FRAMING ALIGNS WITH EDGE OF SLAB AND WILL DETERMINE PLACEMENT OF EXTERIOR WALLS. FLOOR AND ROOF TRUSS DIMENSIONS TO BE VERIFIED ON SITE AND BE SIZED TO ACTUAL FOUNDATION DIMENSIONS. ALL DIMENSIONS ARE TO FACE OF STUD U.N.O. A. B. ALL EXTERIOR OPENINGS ARE TO CENTERLINE, U.N.O. ALL INTERIOR OPENINGS ARE TO CENTERLINE U.N.O. ALL EXTERIOR FRAMING TO BE 2X6 AND INTERIOR FRAMING TO BE 2X4 U.N.O. ALL EXTERIOR FLOOR ELEVATIONS ARE TO TOP OF FINISH GRADE OR FLATWORK, U.N.O. F.O.P. = FACE OF PLYWOOD F.O.F. = FACE OF FINISH 10. REFERENCE BUILDING SECTIONS AND ELEVATIONS FOR ALL VERTICAL DIMENSIONS. 11. COORDINATE FLOOR AND WALL FRAMING WITH M.E.P. 12. INSTALL SOUNDPROOFING FIBERGLASS BATT INSULATION AT WALLS IN THICKNESS TO MATCH FRAMING SIZE AT ALL BEDROOMS AND BATHROOMS. 13. VERITY ALL WINDOW LOCATIONS WITH BRICK COURSING. 14. SEE ENLARGED FLOOR PLANS FOR ADDITIONAL DIMENSIONS AND INFORMATION. 15. SEE A7.1 FOR WALL ASSEMBLIES XA A 1 2 1 . B 7 1 1 . XA MATCHLINE 1 / A131 4 0 2 A / 2 2 0 2 A / 1 0.03 7 1 1 . 6 1 1 . BUILT-IN WINDOW NOOK XD 1.15 1.17A 1.16 BEE'S BATH 116 STEEL PLANTER, RE: LANDSCAPE NEW STAIRS, RE: LANDSCAPE IA EXISTING CASEWORK W/ NEW STONE COUNTERTOP UP 824' - 4 7/8" SKYLIGHT ABOVE NEW STAIR; WOOD RISER AND TREAD " 2 / 1 4 1.13A 827' - 4 3/8" 827' - 5 5/8" 1 A406 EXISTING PATIO TO REMAIN EXISTING TERRAZZO FLOORING LIVING 111 A402 11 12 10 GAS ONLY FIREPLACE AT EXISTING CHIMNEY E 1 1 . 1 " 2 - ' 4 1.10A 1.10B 1.10C 1.10D 1.10E 1.11D 1.11C 1.11B 1.11A " 8 / 5 5 1.11 XE 824' - 4 3/8" EXISTING PATIO TO REMAIN 6'-0 3/4" UP BOOKSHELVES EXISTING TERRAZZO FLOORING MUSIC ROOM 110 BUILT-IN DESK H C N E B N I - T L U B I G 8 0 . 1 1.10A 5 A402 3 / A201 1 FIRST FLOOR PLAN 1/4" = 1'-0" TRUE NORTH PROJECT NORTH PRELIMINARY NOT FOR CONSTRUCTION This drawing is not to be used for regulatory approval, permitting, or construction purposes. ISSUED DATE 03/22/2024 PROJECT NUMBER 2303 DD PRICING E C N E D I S E R S L L I H N R E T S E W I E V R D S L L I H N R E T S E W 4 0 3 5 1 3 7 8 7 X T , N I T S U A A111 FIRST FLOOR PLAN 1 A401 1.08B 4'-6" XA 4'-6" 1.08A SKYLIGHT OPENING ABOVE VAULTED CEILING ABOVE BUILT-IN BED 2 A402 4 1 3 PRIMARY BED 108 EQ EQ 1.08 XD 2 A302 1 A302 1 0 2 A / 1 B 8 0 1 . " 2 / 1 0 1 - ' 5 NEW PATIO AND OUTDOOR SHOWER, RE: LANDSCAPE . F . I . V " 4 / 3 7 - ' 3 - / + . F . I . V " 0 - ' 0 1 - / + . F . I . V " 0 - ' 0 1 - / + . F . I . V " 0 1 - ' 3 - / + . F . I . V " 4 / 3 5 - ' 7 - / + . F . I . V " 0 - ' 9 - / + . F . I . V " 4 / 1 2 - ' 5 - / + . F . I . V " 1 - ' 6 - / + . F . I . V " 4 / 3 1 1 - ' 8 - / + . F . I . V " 4 / 3 0 - ' 5 1 - / + . F . I . V " 2 / 1 0 1 - ' 5 1 1 1.2 1.6 2 3 4 5 6 7 8 9 10 M P 6 5 : 4 2 : 4 4 2 0 2 / 2 2 / 3 | | r r e u t c e t i h c A d a w t u O © r A B C 1 A303 1 A301 D 2 A303 E 3 A303 2 A301 H EXISTING CHIMNEY TO REMAIN, REPAIR AND REFINISH AS NEEDED NEW MEMBRANE ROOF ON EXISTING ROOF STRUCTURE WD1 GENERAL NOTE: REFER TO SHEET G004 FOR SUBCHAPTER F TENTS. MATERIAL TAKEOFF - WOOD SIDING - MATERIAL AREA WD1 WD2 1896 SF 820 SF PRELIMINARY NOT FOR CONSTRUCTION This drawing is not to be used for regulatory approval, permitting, or construction purposes. ISSUED DATE 03/22/2024 PROJECT NUMBER 2303 DD PRICING WD-2 ABOVE WINDOWS AND DOORS, U.N.O. NEW MEMBRANE ROOF ON EXISTING ROOF STRUCTURE T.O.P. CARPORT 116'-8 5/8" T.O.P. HALL CLG 110'-3 3/8" T.O.S. CARPORT 108'-6 5/8" T.O.S. UPPER 105'-0" T.O.S. MAIN 103'-0" " 1 1 - ' 1 T.O.S. LOWER 100'-0" T.O.S. POOL 98'-1" WD1 1.08 1.10A 1.10B 1.10C 1.10D 1.10E 1.11D 1.11C 1.11B 1.11A 1.11 1.13A 1.15 1.16 1.17A WD1 WD1 CANTILEVERED BAY WINDOW NOOK, WD-2 ABOVE AND BELOW BAY WINDOW FENCE AND GATE, RE: LANDSCAPE EXISTING CONCRETE FOUNDATIN WALL TO REMAIN 3 WEST ELEVATION 1/4" = 1'-0" 1 1.2 1.6 2 3 4 5 6 7 8 NEW STEEL & WOOD FLITCH BEAM, RE: STRUCTURAL OPEN TO BEYOND WD-1; REPLACE EXISTING WOOD CLADDING, TYP. NEW SITE GLAZED WINDOWS SKYLIGHT, TYP. NEW STEEL COLUMNS, RE: STRUCTURAL NEW GATE EXISTING STUCCO WALL BEYOND, REPAIR AND REFINISH AS NEEDED EXISTING CONCRETE STEM WALL TO REMAIN NEW WINDOWS 2 NORTH ELEVATION AT ENTRY 1/4" = 1'-0" T.O.P. CARPORT 116'-8 5/8" T.O.P. HALL CLG 110'-3 3/8" T.O.S. CARPORT 108'-6 5/8" T.O.S. UPPER 105'-0" T.O.S. MAIN 103'-0" 1.31A 1.31B 1.31C 1.30A 1.30B WD-2, TYP. PLANTER IN FOREGROUND HIDDEN FLOR CLARITY 1.31D 1.31E WD1 1 1.2 1.6 2 3 4 5 6 7 2 A302 8 1 A302 9 10 M P 2 0 : 5 2 : 4 4 2 0 2 / 2 2 / 3 | | r r e u t c e t i h c A d a w t u O © r EXISTING STUCCO WALL TO REMAIN; REPAIR AND REFINISH AS NEEDED; RE: LANDSCAPE 1.08B 1.08G 1.10A WD-2 ABOVE AND BELOW WINDOW WD-1; REPLACE EXISTING WOOD CLADDING, TYP. PORTION OF EXISTING RAILING TO REMAIN EXISTING CONCRETE STEM WALL TO REMAIN 1 NORTH ELEVATION 1/4" = 1'-0" SKYLIGHT, TYP. WD-2 ABOVE AND BELOW OPENINGS, U.N.O. T.O.P. CARPORT 116'-8 5/8" EXISTING CHIMNEY TO REMAIN; REPAIR AND REFINISH STUCCO AS NEEDED T.O.P. HALL CLG 110'-3 3/8" T.O.S. CARPORT 108'-6 5/8" T.O.S. UPPER 105'-0" T.O.S. MAIN 103'-0" T.O.S. LOWER 100'-0" T.O.S. POOL 98'-1" E C N E D I S E R S L L I H N R E T S E W I E V R D S L L I H N R E T S E W 4 0 3 5 1 3 7 8 7 X T , N I T S U A A201 EXTERIOR ELEVATIONS H 2 A301 3 A303 E 2 A303 D 1 A301 1 A303 C B A SKYLIGHT, TYP. NEW MEMBRANE ROOF ON EXISTING ROOF STRUCTURE EXISTING CONCRETE STEM WALL TO REMAIN WD-1; REPLACE EXISTING WOOD CLADDING, TYP. 2 EAST ELEVATION 1/4" = 1'-0" GENERAL NOTE: REFER TO SHEET G004 FOR SUBCHAPTER F TENTS. MATERIAL TAKEOFF - WOOD SIDING - MATERIAL AREA WD1 WD2 1896 SF 820 SF PRELIMINARY NOT FOR CONSTRUCTION This drawing is not to be used for regulatory approval, permitting, or construction purposes. ISSUED DATE 03/22/2024 PROJECT NUMBER 2303 DD PRICING EXISTING STUCCO RETAINING WALL; REPAIR AND REFINISH AS NEEDED T.O.P. CARPORT 116'-8 5/8" T.O.P. HALL CLG 110'-3 3/8" T.O.S. CARPORT 108'-6 5/8" T.O.S. UPPER 105'-0" T.O.S. MAIN 103'-0" T.O.S. LOWER 100'-0" T.O.S. POOL 98'-1" " 1 1 - ' 1 10 9 1 A302 8 2 A302 7 6 5 4 3 2 1.6 1.2 1 SKYLIGHT, TYP. WD-1; REPLACE EXISTING WOOD CLADDING, TYP. NEW WINDOW IN EXISTING OPENING; NEW DOOR AND WINDOW BELOW OPEN TO BEYOND 1.28B 1.28A 1.28 1.33 1.17B 1.21A EXISTING CONCRETE STEM WALL TO REMAIN EXISTING STUCCO WALL BEYOND, REPAIR AND REFINISH AS NEEDED NEW WOOD FENCE TO MATCH HEIGHT OF EXISTING STUCCO WALL NEW WINDOW " 1 1 - ' 1 " 4 / 1 9 - ' 7 1 I T H G E H G N D L U B I I T.O.P. CARPORT 116'-8 5/8" T.O.P. HALL CLG 110'-3 3/8" T.O.S. CARPORT 108'-6 5/8" T.O.S. UPPER 105'-0" T.O.S. MAIN 103'-0" AVERAGE GRADE 825'-5 3/8" T.O.S. LOWER 100'-0" T.O.S. POOL 98'-1" NEW WD-2 CANTILEVERED WINDOW NOOK NEW WINDOW IN EXISTING OPENING 1.11E 1.11A EXISTING CONCRETE FOUNDATION WALL WD-2 ABOVE AND BELOW WINDOWS, U.N.O. CORNER WINDOW 1 SOUTH ELEVATION 1/4" = 1'-0" M P 8 0 : 5 2 : 4 4 2 0 2 / 2 2 / 3 | | r r e u t c e t i h c A d a w t u O © r E C N E D I S E R S L L I H N R E T S E W I E V R D S L L I H N R E T S E W 4 0 3 5 1 3 7 8 7 X T , N I T S U A A202 EXTERIOR ELEVATIONS C 1 A303 1 A301 WD-1, TYP. D E 2 A303 E D 1 A301 C WD-1, TYP. B C 1 A303 1 A301 T.O.P. CARPORT 116'-8 5/8" T.O.P. HALL CLG 110'-3 3/8" T.O.S. CARPORT 108'-6 5/8" 1.33A 1.34A 1.34B 1.34C WD-2 T.O.P. CARPORT 116'-8 5/8" T.O.P. HALL CLG 110'-3 3/8" T.O.S. CARPORT 108'-6 5/8" 4 WEST ELEVATION AT CARPOT 1/4" = 1'-0" 3 EAST ELEVATION AT CARPORT 1/4" = 1'-0" 2 WEST ELEVATION AT ENTRY 1/4" = 1'-0" H 2 A301 3 A303 E 2 A303 D 1 A301 1 A303 C B A SKYLIGHT, TYP. NEW MEMBRANE ROOF ON EXISTING ROOF STRUCTURE WD-2 ABOVE AND BELOW WINDOWS, U.N.O. STUCCO WALL 1.21B 1.22 1.23A 1.26A 1.26B 1.26C 1.01C 1.01 1.01B 1.05A 1.08A 1.08B NEW FRONT ENTRY DOOR WD-1; REPLACE EXISTING WOOD CLADDING, TYP. EXISTING CONCRETE STEM WALL TO REMAIN " 1 1 - ' 1 1 EAST ELEVATION AT ENTRY 1/4" = 1'-0" M P 3 1 : 5 2 : 4 4 2 0 2 / 2 2 / 3 | | r r e u t c e t i h c A d a w t u O © r GENERAL NOTE: REFER TO SHEET G004 FOR SUBCHAPTER F TENTS. MATERIAL TAKEOFF - WOOD SIDING MATERIAL AREA WD1 3568 SF PRELIMINARY NOT FOR CONSTRUCTION This drawing is not to be used for regulatory approval, permitting, or construction purposes. ISSUED DATE 03/22/2024 PROJECT NUMBER 2303 DD PRICING T.O.P. CARPORT 116'-8 5/8" T.O.P. HALL CLG 110'-3 3/8" T.O.S. CARPORT 108'-6 5/8" T.O.S. UPPER 105'-0" T.O.P. CARPORT 116'-8 5/8" T.O.P. HALL CLG 110'-3 3/8" T.O.S. CARPORT 108'-6 5/8" T.O.S. UPPER 105'-0" T.O.S. MAIN 103'-0" T.O.S. LOWER 100'-0" T.O.S. POOL 98'-1" E C N E D I S E R S L L I H N R E T S E W I E V R D S L L I H N R E T S E W 4 0 3 5 1 3 7 8 7 X T , N I T S U A A203 EXTERIOR ELEVATIONS P.14 P.13 P.12 P.11 10 9 8 7 6 5 4 3 2 1.6 1.2 1 1.11E 1.11A 1.17B 1.21A 1.28B 1.28A 1.28 1.33 2 SOUTH - SITE ELEVATION 3/16" = 1'-0" M P 9 1 : 5 2 : 4 4 2 0 2 / 2 2 / 3 | | r r e u t c e t i h c A d a w t u O © r 1 NORTH - SITE ELEVATION 3/16" = 1'-0" 1 1.2 1.6 2 3 4 5 6 7 8 9 10 P.11 P.12 P.13 P.14 1.31A 1.31B 1.31C 1.30A 1.30B 1.08B 1.08G 1.10A PRELIMINARY NOT FOR CONSTRUCTION This drawing is not to be used for regulatory approval, permitting, or construction purposes. ISSUED DATE 03/22/2024 PROJECT NUMBER 2303 DD PRICING T.O.P. CARPORT 116'-8 5/8" T.O.S. CARPORT 108'-6 5/8" T.O.S. UPPER 105'-0" T.O.S. MAIN 103'-0" T.O.S. LOWER 100'-0" T.O.S. POOL 98'-1" T.O.P. CARPORT 116'-8 5/8" T.O.S. CARPORT 108'-6 5/8" T.O.S. UPPER 105'-0" T.O.S. MAIN 103'-0" T.O.S. LOWER 100'-0" T.O.S. POOL 98'-1" E C N E D I S E R S L L I H N R E T S E W I E V R D S L L I H N R E T S E W 4 0 3 5 1 3 7 8 7 X T , N I T S U A A204 EXTERIOR ELEVATIONS P.G 2 A301 P.F P.14 P.13 P.12 P.11 STUCCO 1/4" / 1'-0" 1.37 OUTDOOR KITCHEN STUCCO T.O.P. HALL CLG 110'-3 3/8" T.O.S. POOL 98'-1" 4 EAST ELEVATION — POOL 1/4" = 1'-0" 3 SOUH ELEVATION — POOL 1/4" = 1'-0" P.F 2 A301 P.G P.11 P.12 P.13 P.14 T.O.P. HALL CLG 110'-3 3/8" 1/4" / 1'-0" 1.38 STUCCO T.O.S. POOL 98'-1" STUCCO 36" RAILING, RE: LANDSCAPE 2 WEST ELEVATION — POOL 1/4" = 1'-0" 1 NORTH ELEVATION — POOL 1/4" = 1'-0" M P 4 2 : 5 2 : 4 4 2 0 2 / 2 2 / 3 | | r r e u t c e t i h c A d a w t u O © r GENERAL NOTE: REFER TO SHEET G004 FOR SUBCHAPTER F TENTS. PRELIMINARY NOT FOR CONSTRUCTION This drawing is not to be used for regulatory approval, permitting, or construction purposes. ISSUED DATE 03/22/2024 PROJECT NUMBER 2303 DD PRICING T.O.P. HALL CLG 110'-3 3/8" T.O.S. POOL 98'-1" T.O.P. HALL CLG 110'-3 3/8" T.O.S. POOL 98'-1" E C N E D I S E R S L L I H N R E T S E W I E V R D S L L I H N R E T S E W 4 0 3 5 1 3 7 8 7 X T , N I T S U A A205 EXTERIOR ELEVATIONS — POOL