9 - 407 E Monroe St - plans and elevations — original pdf
Backup
12X30 POOL UP REAR PATIO N E V O L L A W . F E R " 2 4 COV'D PORCH ROOF DECK RESIDENTIAL & HOSPITALITY ARCHITECTURE & PLANNING 1212 Chicon Street Ste. 101 Austin, TX 78702 (512) 473. 8228 Voice www.element5architecture.com THIS SET OF DRAWINGS IS FOR INTERIM REVIEW ONLY THIS DOCUMENT IS INCOMPLETE NOT FOR REGULATORY APPROVAL / PERMITTING / BIDDING OR CONSTRUCTON NICK MEHL REGISTRATION NO. 17752 MONROE RESIDENCE 407 E MONROE AUSTIN, TX 78704 SITE PLAN A1.0 © COPYRIGHT 2019 , E5A . ALL RIGHTS RESERVED 1 SITE PLAN 1/8" = 1'-0" NOTE: ALL SITE & SURVEY INFORMATION PROVIDED BY OTHERS t v r . 2 T P O I \ - E O R N O M T V E R \ e o r n o M \ s t n e m u c o D m a S \ s r e s U \ \ : C M P 1 5 : 0 3 : 4 2 2 0 2 / 1 1 / 5 CLST MASTER BATH N E V O L L A W . F E R " 2 4 ENTRY UP DN ELEVATOR POWDER COV'D PORCH DN UP REAR PATIO KITCHEN DINING LIVING ROOF DECK RESIDENTIAL & HOSPITALITY ARCHITECTURE & PLANNING 1212 Chicon Street Ste. 101 Austin, TX 78702 (512) 473. 8228 Voice www.element5architecture.com THIS SET OF DRAWINGS IS FOR INTERIM REVIEW ONLY THIS DOCUMENT IS INCOMPLETE NOT FOR REGULATORY APPROVAL / PERMITTING / BIDDING OR CONSTRUCTON NICK MEHL REGISTRATION NO. 17752 MONROE RESIDENCE 407 E MONROE AUSTIN, TX 78704 1446 SF FLOOR PLANS A2.0 © COPYRIGHT 2019 , E5A . ALL RIGHTS RESERVED GAME MEDIA ROOM MASTER BDRM PANTRY WINE STORAGE ELEVATOR UP BATH GARAGE UP 1 BASEMENT FLOOR 1/4" = 1'-0" 2 FIRST FLOOR 1/4" = 1'-0" t v r . 2 T P O I \ - E O R N O M T V E R \ e o r n o M \ s t n e m u c o D m a S \ s r e s U \ \ : C M P 2 5 : 0 3 : 4 2 2 0 2 / 1 1 / 5 BDRM 1 CLST BDRM 2 CLST BATH 2 FLEX BATH 1 LINEN LAUNDRY ELEVATOR UP DN BATH 3 BDRM 3 CLST FLEX 952 SF 3 SECOND FLOOR 1/4" = 1'-0" 4 ATTIC FLOOR 1/4" = 1'-0" RESIDENTIAL & HOSPITALITY ARCHITECTURE & PLANNING 1212 Chicon Street Ste. 101 Austin, TX 78702 (512) 473. 8228 Voice www.element5architecture.com THIS SET OF DRAWINGS IS FOR INTERIM REVIEW ONLY THIS DOCUMENT IS INCOMPLETE NOT FOR REGULATORY APPROVAL / PERMITTING / BIDDING OR CONSTRUCTON NICK MEHL REGISTRATION NO. 17752 MONROE RESIDENCE 407 E MONROE AUSTIN, TX 78704 FLOOR PLANS A2.1 © COPYRIGHT 2019 , E5A . ALL RIGHTS RESERVED t v r . 2 T P O \ I - E O R N O M T V E R \ e o r n o M \ s t n e m u c o D m a S \ s r e s U \ \ : C M P 3 5 : 0 3 : 4 2 2 0 2 / 1 1 / 5 " 2 1 / " 3 METAL ROOF 9" / 12" 9" / 12" METAL ROOF CRICKET " 2 1 / " 3 TPO ROOF 9" / 12" METAL ROOF 9" / 12" ROOF DECK 1 ROOF PLAN 1/4" = 1'-0" RESIDENTIAL & HOSPITALITY ARCHITECTURE & PLANNING 1212 Chicon Street Ste. 101 Austin, TX 78702 (512) 473. 8228 Voice www.element5architecture.com THIS SET OF DRAWINGS IS FOR INTERIM REVIEW ONLY THIS DOCUMENT IS INCOMPLETE NOT FOR REGULATORY APPROVAL / PERMITTING / BIDDING OR CONSTRUCTON NICK MEHL REGISTRATION NO. 17752 MONROE RESIDENCE 407 E MONROE AUSTIN, TX 78704 ROOF PLAN A2.2 © COPYRIGHT 2019 , E5A . ALL RIGHTS RESERVED t v r . 2 T P O \ I - E O R N O M T V E R \ e o r n o M \ s t n e m u c o D m a S \ s r e s U \ \ : C M P 4 5 : 0 3 : 4 2 2 0 2 / 1 1 / 5 STUCCO BRICK BOARD AND BATTEN METAL SIDING & ROOF EXTERIOR MATERIALS BOARD AND BATTEN BOARD AND BATTEN METAL ROOF ATTIC FLOOR 22' - 4 1/2" SECOND FLOOR PLAN 11' - 8 1/4" STUCCO FIRST FLOOR 0' - 0" ENTRY -4' - 10 1/8" BASEMENT FLOOR -9' - 8 1/4" 1 SOUTH ELEVATION 1/4" = 1'-0" t v r . 2 T P O \ I - E O R N O M T V E R \ e o r n o M \ s t n e m u c o D m a S \ s r e s U \ \ : C M P 3 1 : 1 3 : 4 2 2 0 2 / 1 1 / 5 METAL ROOF STUCCO ATTIC FLOOR 22' - 4 1/2" SECOND FLOOR PLAN 11' - 8 1/4" METAL SIDING BOARD AND BATTEN BRICK FIRST FLOOR 0' - 0" BRICK BASEMENT FLOOR -9' - 8 1/4" 2 EAST ELEVATION 1/4" = 1'-0" RESIDENTIAL & HOSPITALITY ARCHITECTURE & PLANNING 1212 Chicon Street Ste. 101 Austin, TX 78702 (512) 473. 8228 Voice www.element5architecture.com THIS SET OF DRAWINGS IS FOR INTERIM REVIEW ONLY THIS DOCUMENT IS INCOMPLETE NOT FOR REGULATORY APPROVAL / PERMITTING / BIDDING OR CONSTRUCTON NICK MEHL REGISTRATION NO. 17752 STUCCO STUCCO STUCCO MONROE RESIDENCE 407 E MONROE AUSTIN, TX 78704 EXTERIOR ELEVATIONS A3.0 © COPYRIGHT 2019 , E5A . ALL RIGHTS RESERVED STUCCO BRICK BOARD AND BATTEN METAL SIDING & ROOF EXTERIOR MATERIALS ATTIC FLOOR 22' - 4 1/2" ATTIC FLOOR 22' - 4 1/2" METAL ROOF RESIDENTIAL & HOSPITALITY ARCHITECTURE & PLANNING 1212 Chicon Street Ste. 101 Austin, TX 78702 (512) 473. 8228 Voice www.element5architecture.com THIS SET OF DRAWINGS IS FOR INTERIM REVIEW ONLY THIS DOCUMENT IS INCOMPLETE NOT FOR REGULATORY APPROVAL / PERMITTING / BIDDING OR CONSTRUCTON NICK MEHL REGISTRATION NO. 17752 MONROE RESIDENCE 407 E MONROE AUSTIN, TX 78704 EXTERIOR ELEVATIONS A3.1 © COPYRIGHT 2019 , E5A . ALL RIGHTS RESERVED BOARD AND BATTEN METAL ROOF SECOND FLOOR PLAN 11' - 8 1/4" METAL SIDING FIRST FLOOR 0' - 0" BRICK ENTRY -4' - 10 1/8" BASEMENT FLOOR -9' - 8 1/4" SECOND FLOOR PLAN 11' - 8 1/4" STUCCO STUCCO FIRST FLOOR 0' - 0" 3 NORTH ELEVATION 1/4" = 1'-0" 4 WEST ELEVATION 1/4" = 1'-0" STUCCO STUCCO t v r . 2 T P O \ I - E O R N O M T V E R \ e o r n o M \ s t n e m u c o D m a S \ s r e s U \ \ : C M P 6 2 : 1 3 : 4 2 2 0 2 / 1 1 / 5 5/17/22, 3:24 PM Back Side.jpg https://drive.google.com/file/d/1QmDm3mIysC2YUOYFXMDWm8tKEEtJPfql/view 1/1 5/17/22, 3:25 PM Detail 1.jpg https://drive.google.com/file/d/1inpT1UIZo2cQyvTLe7J_38y87Pls3nC_/view 1/1 ammond, Consulting & Engineering, LLC Residential & Commercial Structural Solutions Texas Firm# 17051 email: rhammond@RDHCE.com phone: 956.367.5561 04/08/2022 Oam Parkash & Eva Khazana 512.945.0788 Austin, Texas Dear Mr. Parkash & Ms. Khazana, On 05 April 2022, R. Derek Hammond of RDH C&E performed a site observation to 407 E. Monroe Street in Austin, Texas to view the condition of the existing ADU. Based on the site observations, and calculations it appears the roof, attic, and portions floor framing are over spanned and insufficient for code required loading. Sagging in framing, cracking within the veneer, and rotting within the soffit and around the bottom plate were also observed. Roof & upper attic framing would all need to be removed and replaced or reinforced with additional framing and bracing. The 4x6 2nd floor framing support was also found to be deficient and would need to be reinforced or removed and replaced. Rotting was noted around the perimeter of the building due to the proximity of grade to the bottom plate of the wall. Termite damage was confirmed, and all wall framing at was damaged would need to be replaced. The following report details site observations, conclusions and recommendations for the structure. If you have any questions, please do not hesitate to contact us. Thank you for the opportunity to provide these services to you. If we have erred in our understanding of the work feel free to contact me and we will be happy to adjust and resend, Respectfully, R. Derek Hammond, PE Owner RDH C&E LLC ammond, Consulting & Engineering, LLC Residential & Commercial Structural Solutions Texas Firm# 17051 email: rhammond@RDHCE.com phone: 956.367.5561 General Conditions The existing apartment dwelling unit (ADU) was located at 407 East Monroe in Southwest Austin, Texas. The front of the residence faces north, toward East Monroe. The residence is located East of I-35 approximately 2 miles and south of Lady Bird Lake approximately 1 mile. The existing structure was a two story, stick framed structure resting on concrete stem walls with a slab on grade foundation. Structure Composition Roof and attic framing were composed of 2x4’s at 24” OC. Hip and ridge beams were also 2x4 framing members. Floor and roofs were decked with ship lap boards and wall covering. The lateral system appeared to be braced walls. Wall sheathing and wall framing at the second floor were concealed and unable to be view during the observation. The second floor framing was composed of 2x8’s at 16” on center (OC) resting on a 4x6 beam that ran the length of the building parallel to the front of the building. The concrete stem walls were approximately 2’-0” to 3’-0” tall and retained soil from the South and West sides. Reinforcement within the slab and stem wall were unable to be determined. Structural Issues/Deficiencies Roof framing and attic framing ( 2x4’s at 24”) were determined to be deficient for code required live and dead loading. Ridge and hip beams were also undersized and would need to be increased in size, or braced from walls below. The 2x8 floor framing is adequately sized provided no additional point loading is added to it from the roof above. The 4x6 framing carrying the 2x8’s however were undersized for the required loading. The 4x6 beam center support was concealed from view and unable to be confirmed, a 4x4 post and foundation would be required for the loading. Soils around the South and West sides were observed to be above the bottom plate of the wooden portions of the exterior wall framing. Cracking was observed in the skirting around the base of the home and sand bags were present to mitigate water infiltration. Wall framing was obscured from view, but is likely rotted due to the evidence of water infiltration over a long period of time. Rotting soffits were also noted around the perimeter of the ADU as well as evidence of settling, namely cracking around openings. Termite damage had been confirmed within the walls, further investigation would be necessary to determine wall framing adequacy. Where damage or insufficient framing and/or sheathing attachments are discovered, removal and replacement would be recommended. Conclusions Roof framing, sheathing, attic framing and wall framing are deficient for current code required loading and likely water and/or termite damaged, respectively. Roof framing members and attic framing would need to be upgraded to 2x6 framing at the roof, 2x10’s at the attic, and ridges would need to be reinforced, and possibly braced off of the interior walls. Bracing off of walls would require the 2x8 floor framing to be upgraded to support the added point loading from the roof bracing. The 4x6 framing ammond, Consulting & Engineering, LLC Residential & Commercial Structural Solutions Texas Firm# 17051 email: rhammond@RDHCE.com phone: 956.367.5561 supporting the floor framing would need to be removed and replaced with a larger beam, but may create head height issues, so special consideration will need to be taken. Damaged walls and sheathing would need to be replaced, and evidence of damage was noted around the entire exterior. Roof, attic framing, and primary 2nd floor framing support were noted as deficient, some to severe degrees. Removal and replacement would be necessary to a large portion of ADU wood framing. Headers were concealed from view and unable to be confirmed, but will also likely require replacement as well. Foundations and stem walls appeared in tact, however reinforcement (if any) was not confirmed, nor slab depth, grade beam depth, or the existence of spread footings below the interior support for the second floor framing. Further investigation would be necessary, but after trenching for plumbing, water proofing for the retaining wall, and re-grading to avoid water infiltration on the rear, it may be more economical to demo the slab and stem walls as well. Shoring or replacement of the 4x6 beam would be recommended to avoid safety issue for any work crews prior to working on the ADU. ammond, Consulting & Engineering, LLC Residential & Commercial Structural Solutions Texas Firm# 17051 email: rhammond@RDHCE.com phone: 956.367.5561 Figure 1: 2x4 roof framing at 24”, 2x4 ridge beam, and 2x4hip beam, note lack of vertical support at hip to ridge connection. ammond, Consulting & Engineering, LLC Residential & Commercial Structural Solutions Texas Firm# 17051 email: rhammond@RDHCE.com phone: 956.367.5561 Figure 2: 2x8 floor framing at 16”. Figure 3: Rear wall, SW corner, sand bags, and soil built up above bottom plate. ammond, Consulting & Engineering, LLC Residential & Commercial Structural Solutions Texas Firm# 17051 email: rhammond@RDHCE.com phone: 956.367.5561 Figure 4: Rotting soffit and crack stucco veneer on rear wall ammond, Consulting & Engineering, LLC Residential & Commercial Structural Solutions Texas Firm# 17051 email: rhammond@RDHCE.com phone: 956.367.5561 Figure 5: Rotted soffit on West side of ADU. 4/5/22, 10:23 AM designtreehome.com Mail - A-Tex Pest Management A-Tex Pest Management 1 message Chris Roddy <cratexpest@gmail.com> To: eva@designtreehome.com eva konvit <eva@designtreehome.com> Fri, Apr 1, 2022 at 9:58 AM Hi this is Chris with A-Tex Pest Management. I am the one who performed the termite inspection for both 407 and 409 Monroe. I have sent over a treatment plan for both including treatment around the detached garage. I highly recommend a treatment due to all the conducive conditions for example wood touching the ground which also hides areas during the inspection. Also the condition of the wood sitting on all 3 structures is in poor condition which attracts termites. While on site I saw no evidence or proof a treatment had been done so in those cases we recommend having the property treated and in tern will provide protection. The product we use states it provides protection against termites for up to 15 years and will also eliminate and existing termites in 90 days. I hope this recommendation email helps and we look forward to your business. Thanks, Chris Sent from my iPad https://mail.google.com/mail/u/1/?ik=d88eca4a7e&view=pt&search=all&permthid=thread-f%3A1728918494360580470&simpl=msg-f%3A1728918494360580470 1/1 3/30/22, 12:05 PM Customer Portal Welcome EVA Thank you for choosing A-TEX PEST MANAGEMENT INC! Welcome to our newly featured customer portal, for your convenience you may pay your bill from here, see your service history and invoice details as well, it is our goal to provide as many tools as possible to make your service experience with us 2nd to none! Thank you for allowing us to serve you! Please review the following document and then sign. You will receive a copy via email for your records. Thank you! https://atexpest.pestportals.com/signForm?code=23294&codex=3430373635&lID=b42d90535b0b417693a1298dae634341 1/6 3/30/22, 12:05 PM Customer Portal https://www.atexpest.com P.O. Box 80081 - Austin, Texas 78708 (512) 428-6967 TPCL#12357 MAPSCO EVA CONVIT Account Name 407 E MONROE ST Service Address Austin Service City (512) 751-5667 Service Phone # TX State 78704 Zip Person To Contact 3/30/22 Date EVA CONVIT Billing Name 407 E MONROE ST Billing Address Austin Billing City (512) 751-5667 Billing Phone # TX State 78704 Zip Person To Contact Email eva@designtreehome.com Termite Service Agreement This agreement is by and between A-TEX and the party indicated above and hereinafter referred to as the "Company" (the seller) and the "Customer" (the buyer). The Company agrees to finish Eastern Subterranean termite control service to the structure(s) specified above under the "service address" and to guarantee this treatment for a period of one year from the date of treatment, subject to general terms and conditions (refer to the "General Terms and Conditions" on the back of this document). Limited Lifetime Renewable Termite Re-Treatment Agreement Subject to any limitations or restrictions set forth in the graph, specifications, inspection reports and to the General terms and conditions, the Company will issue a Re-treatment Agreement. This Agreement obligates the company, at no extra cost to the customer, to perform any necessary additional treatment to the customer's building if any infestation of subterranean termites is found during the effective period of this agreement. After completion of the initial treatment, the agreement will apply to the building at the above stated service address and described in the attached graph. The Agreement will be effective when the initial charge for treatment are paid and after that, upon payment of the annual renewal fee on or before each anniversary date of the agreement. The annual renewal fee indicated below is due on the anniversary date of the initial treatment. The annual renewal fee is subject to increase after the 5th fiscal year no more than 10% per year. So long as the Agreement is in effect, the company will reinspect the building located at the service address when the Company determines it is necessary, or unusually upon request. The customer agrees to make the building available for inspection. Customer warrants full cooperation with the company, and agrees to maintain the building located at the service address free from any condition conducive to re-infestation, such as excessive moisture, wood debris, trash or allowing lumber or wood adjacent or attached to the building to come in direct contact with the ground. Any alterations or additions to the building shall not be included in this agreement unless the company has also treated the additions. This agreement may be transferred to any new owner at any time, the service and warranty does not include Drywood, or Formosan Termites. Annual Renewal Fee $ 150 Plus tax, per year Type of Treatment [ ]Baiting [X]Partial (Chemical) [ ]Spot (Chemical) [ ]Physical Barrier [ ]Pier & Beam (Refer to the "Definitions of Treatment" on the back of this document) START DATE --/ -- / -- Chemical to be used TERMIDOR HE at .125 % [X]Attach Copy of Label [X]Attach MSDS Sheet [X]Prep. Sheet Attached [X]Attach Graph showing termite treating specs. [X]Consumer Information Sheet Treatment Charge $ 625 + Tax $ 51.56 = $ 676.56 -- Inspections Recommended Annually Amount Remitted with this Agreement $ You, the buyer, may cancel this transaction at anytime prior to midnight of the third business day after the date of this transaction. Ask for details and/or see the back of this document. https://atexpest.pestportals.com/signForm?code=23294&codex=3430373635&lID=b42d90535b0b417693a1298dae634341 2/6 3/30/22, 12:05 PM Customer Portal In the event payment is not met, A-TEX will submit for collection and all expenses, charges, fees, etc. will be added to the amount due and owed by Customer. There will be a $25.00 fee for all returned checks. The undersigned property owner/customer acknowledges that they have read and understand the foregoing agreement. They also understand that they will be bound by its terms. A-TEX PEST MANAGEMENT INC. ACCEPTED BY: Chris Roddy Representative Name Special Instructions/Payment Arrangements: LICENSED & REGULATED BY: TEXAS DEPARTMENT OF AGRICULTURE P.O. BOX 12847 AUSTIN, TX 78711-2847, PHONE: (806) 918-4481, FAX:(888) 232-2567 https://atexpest.pestportals.com/signForm?code=23294&codex=3430373635&lID=b42d90535b0b417693a1298dae634341 3/6 3/30/22, 12:05 PM GENERAL TERMS AND CONDITIONS Customer Portal It is agreed that the Company is not responsible for the repair of visible or hidden damage existing as of the date of his contract. It is further agreed that the customer is solely responsible for the repair of such damage. Excessive moisture, structural or mechanical defects which result in water leakage and stress cracks in foundation and sub-slab areas may destroy the effectiveness of the treatment and permit the infestation to continue after the date of initial treatment. If moisture and/or structural conditions which are conductive to subterranean termite infestation (such as structural wood to ground contact, water leakage stucco/veneer below grade, firewood adjacent to structure, milch beds adjacent to structure) are found to exist after the date of this agreement the Company shall be relieved of any and all liability for damage occurring during the term of this agreement. If such repairs are discovered, it is agreed that the customer will be responsible for making such repairs as are necessary to correct the defect and the company will within one year from the date of this contract, upon completions of said repairs, provide treatment to control the infestation. Any claim for breach of this guarantee shall be made in writing to the Company. The parties hereto agree to submit all disputes to binding arbitration if the parties are unable to agree to a resolution of any dispute. In no event may any lawsuit be brought more than two (2) years after the breach of the guarantee. The Company's liability shall be terminated should the Company be prevented from fulfilling its responsibilities under the terms of the Guarantee by reason of acts of war, whether declared or undeclared, acts of any duly constituted government authority, strikes, acts of God, or failure by the customer to allow the Company access to the premises for any purpose contemplated by the Guarantee, specifically including re-inspection, whether such re-inspection was requested by the customer or deemed necessary by the Company. This agreement covers the premises diagram on the attached Graph and specifications as of the date actual treatment, and the event the premises are structurally modified, altered, sold, transferred or otherwise changed after date of initial treatment, this agreement shall terminate as to that portion modified, altered, sold, transferred or changed unless a prior written agreement shall have been entered into between the customer and the Company to re-inspect the premises, provide additional treatment and/or adjust the annual renewal fee. It is understood and agreed between the parties that this Agreement, the attached Graph and specifications constitute the complete agreement between the parties and that said agreement may not be transferred, changed or altered in any manner, oral or otherwise, unless the alteration or change is in writing and executed by a duly authorized representative of the Company. It is specifically understood and agreed that the Company and the Customer are bound only by the terms and conditions of this agreement and have not relied on any other representation oral or otherwise. Customer acknowledges and agrees that no insecticides shall be applied to the baited/monitored sites, that all bait stations shall remain the property of the company, that customer shall be responsible for missing or damaged bait stations, and that customer shall not move, open or handle bait stations. Customer acknowledges and agrees that control subterranean termites through a baiting system shall be provided through baiting and monitoring by the company. The subterranean termite baiting system is designed to reduce and/or eliminate termite activity to the extent required to provide structural protection from further damage, Achievement of this end result make take several months or in some cases longer depending on the size and number of termite colonies presents, the number of conductive conditions, the treatment method used, and the number of station used and their placement. Additional damage may occur because of the time needed to gain control. The company will not be responsible for such damage. It is agreed that the agreement does not cover Drywood, Formosan or any other species of Termites other than Eastern Subterranean Termites. A subterranean termite treatment may be a partial treatment or a spot treatment using termiticide, approved physical barriers or a baiting system, These types of treatments are defined as follows: DEFINITIONS OF TREATMENT This technique allows a wide variety of treatment strategies but is more involved than a spot treatment. (See definition below.) Ex: treatment of some or all of the perimeter, bath traps, expansion joints, stress cracks, portions of framing, walls and bait locations. Pier and Beam: Generally defined as the treatment of the outer perimeter including porches, patios and treatment of the attached garage. In the crawl space, treatment would include any soil to structure contacts as well as removal of any wood debris on the ground. Slab Construction: Generally defined as treatment of the perimeter and all known slab penetrations as well as any known expansion joints or stress cracks. Any treatment which concerns a limited, defined area less than ten (10) linear or square feet that is intended to protect a specific location or "spot." Often there are adjacent areas susceptible to termite infestation, which are not treated. Partial Treatment Spot Treatment Baiting This type of treatment may include interior and/or perimeter placement of monitoring or baiting systems along with routine inspection intervals. The baiting technique may include one or more baiting locations as prescribed by the product label and instructions. For all treatment there will be a graph showing exactly what will be treated. Treatment specifications and warranties for those treatments may vary widely. Review the pesticides label provided to you for minimum treatment specifications. If you have any questions, contact the service provider or the Texas Department of Agriculture P.O. Box 12847, Austin, TX 78711 Phone:866-918-4481 or Fax: 888-232-2567 Notice of Cancellation I, the buyer, having been informed of my right to cancel this transaction at anytime prior to midnight of the third business day after the date of this transaction hereby exercise my right of cancellation. Buyer Date: Time: https://atexpest.pestportals.com/signForm?code=23294&codex=3430373635&lID=b42d90535b0b417693a1298dae634341 4/6 3/30/22, 12:05 PM Customer Portal https://www.atexpest.com P.O. Box 80081 - Austin, Texas 78708 (512) 428-6967 TPCL#12357 X = ACTIVE TERMITES A = TRENCH B = DRILL C = BATH & TRAPS D = WASHER/DRYER E = SINKS F = ICE MAKER G = SHOWER PAN H = ROD I = LONG ROD NOTES 1 SQ# FT APPROX: 125 LIN. FT. Name: EVA CONVIT APPROX: 30-40 CHEM. GALS. Address: 407 E MONROE ST APPROX: 2-3 HR. LABOR Austin, TX 78704 Phone #: H (512) 751-5667 W TOTAL $ 625 GRAPHED BY: CR SERVICE CHARGE $ TAX $ TOTAL:$ + Add Diagram Legend Finish https://atexpest.pestportals.com/signForm?code=23294&codex=3430373635&lID=b42d90535b0b417693a1298dae634341 5/6 3/30/22, 12:05 PM Customer Portal Powered by (https://facebook.com/atexpest) (https://twitter.com/atexpest) (https://plus google com/112999748095690493492) A-TEX PEST MANAGEMENT INC PO BOX 80081 AUSTIN, TX 78708 https://atexpest.pestportals.com/signForm?code=23294&codex=3430373635&lID=b42d90535b0b417693a1298dae634341 6/6