Historic Landmark CommissionJuly 6, 2022

C.11.1 - 1004 Spence St - Plans — original pdf

Backup
Thumbnail of the first page of the PDF
Page 1 of 5 pages

CAUTION: DO NOT SCALE DRAWINGS THESE DRAWINGS ARE THE PROPERTY OF THE ARCHITECT AND MAY ONLY BE USED IN CONJUNCTION WITH THIS PROJECT. SET ISSUE DRAWN BY PROJECT 6/8/22 | Schematic Design at Spence Street ADU 1004 Spence Street Austin TX 78702 DRAWING TITLE YARD VIEW T E E R T S E C N E P S ' 0 9 . 3 9 E " 1 0 6 3 ° 9 1 N ' Picnic Area FRIDGE 2 n d L e v e l T e r r a c e Main House (not in scope) Back Porch Scope of Work t k c a b e S r a e R ' 0 1 t k c a b e S r a e R ' 5 2-Story ADU over Garage UP D / W Rolling Gate ' 0 9 . 3 9 W " 0 0 0 0 ° 0 2 N ' Y E L L A Permeable Surface 1-Story Pool House Roof Side Yard Pool 5' Building Setback k c a b e S t t n o r F ' 5 2 Low Fence 6' High Fence 5' Building Setback 112' FROM STREET N69°51'22"W 129.94' CAUTION: DO NOT SCALE DRAWINGS THESE DRAWINGS ARE THE PROPERTY OF THE ARCHITECT AND MAY ONLY BE USED IN CONJUNCTION WITH THIS PROJECT. SET ISSUE DRAWN BY PROJECT DRAWING TITLE 6/8/22 | Schematic Design at Spence Street ADU 1004 Spence Street Austin TX 78702 Schematic Site Plan SITE PLAN SCALE: 3/32" = 1'-0" N T E E R T S E C N E P S ' 0 9 . 3 9 E " 1 0 6 3 ° 9 1 N ' Picnic Area FRIDGE 2 n d L e v e l T e r r a c e Main House (not in scope) Back Porch Scope of Work t k c a b e S r a e R ' 0 1 t k c a b e S r a e R ' 5 2-Story ADU over Garage UP D / W Rolling Gate ' 0 9 . 3 9 W " 0 0 0 0 ° 0 2 N ' Y E L L A Permeable Surface 1-Story Pool House Roof Side Yard Pool 5' Building Setback k c a b e S t t n o r F ' 5 2 Low Fence 6' High Fence 5' Building Setback 112' FROM STREET N69°51'22"W 129.94' CAUTION: DO NOT SCALE DRAWINGS THESE DRAWINGS ARE THE PROPERTY OF THE ARCHITECT AND MAY ONLY BE USED IN CONJUNCTION WITH THIS PROJECT. SET ISSUE DRAWN BY PROJECT DRAWING TITLE 6/8/22 | Schematic Design at Spence Street ADU 1004 Spence Street Austin TX 78702 Schematic Site Plan SITE PLAN SCALE: 3/32" = 1'-0" N Low slope flat roof Concrete wall panels 3-coat stucco Low fence & gate Concrete wall panels 3-coat stucco 3-coat stucco PARAPET +22'-2" PLATE HT +19'-2" FFE LEVEL 2 +12'-0" FFE LEVEL 1 0" PARAPET +22'-2" PLATE HT +19'-2" PLATE HT +12'-0" Low slope flat roof Concrete wall panels Perimeter fence, beyond NORTH ELEVATION SCALE: 1/8" = 1'-0" SOUTH ELEVATION SCALE: 1/8" = 1'-0" FFE LEVEL 1 0" CAUTION: DO NOT SCALE DRAWINGS THESE DRAWINGS ARE THE PROPERTY OF THE ARCHITECT AND MAY ONLY BE USED IN CONJUNCTION WITH THIS PROJECT. SET ISSUE DRAWN BY PROJECT DRAWING TITLE 6/8/22 | Schematic Design at Spence Street ADU 1004 Spence Street Austin TX 78702 Schematic Elevations Metal roof PARAPET +22'-2" PLATE HT +19'-2" 3-coat stucco FFE LEVEL 2 +12'-0" Perimeter fence, beyond FFE LEVEL 1 0" Main House (not in scope) WEST ELEVATION SCALE: 1/8" = 1'-0" Low slope flat roof PLATE HT +12'-0" Concrete wall panels Perimeter fence, beyond FFE LEVEL 1 0" EAST ELEVATION SCALE: 1/8" = 1'-0" Main House (not in scope) CAUTION: DO NOT SCALE DRAWINGS THESE DRAWINGS ARE THE PROPERTY OF THE ARCHITECT AND MAY ONLY BE USED IN CONJUNCTION WITH THIS PROJECT. SET ISSUE DRAWN BY PROJECT DRAWING TITLE 6/8/22 | Schematic Design at Spence Street ADU 1004 Spence Street Austin TX 78702 Schematic Elevations