A FULL RESIDENTIAL SPRINKLER SYSTEM DESIGNED, INSTALLED AND TESTED IN ACCORDANCE WITH THE NFPA 13D OR THE 2015 IRC P2904 STANDARDS WILL BE INSTALLED IN THIS PROPERTY. THE PLANS FOR THE SPRINKLER SYSTEM MUST DESIGNED AND INSTALLED BY A TEXAS LICENSED SPRINKLER CONTRACTOR FOR NFPA 13D SYSTEMS OR A TEXAS LICENSED PLUMBER WITH THE IRC P2904 ENDORSEMENT ON THEIR LICENSE. THE SPRINKLER PLANS MUST BE SUBMITTED, REVIEWED, APPROVED, TESTED AND INSPECTED BY AFD PRIOR TO COVERING THE WALLS AND CEILINGS. EP 3FT PUE (N30°01'E 65') OH ELECTRIC EP PML 15FT AE SETBACK 27'-0" 29'-10" 605.2 604.6 605 10'-6" 605.1 604.7 PROPERTY LINE AAG LP=602.7 BLDG SETBACK [COA] ) ' 0 . 0 1 1 W ' 1 4 ° 9 5 N ( 5'-0" 8'-0" E U P T F 3 POOL/SPA 30X15 CONCRETE PATIO PROPOSED 2-STORY RESIDENCE FFE=601.0 AAG=601.7 ) ' 0 . 0 1 1 E ' 1 4 ° 9 5 S ( E I P U Q E L O O P C A C A C A G E U P T F 3 7'-2" 5'-0" 40'-0" TENT PORTION 2 HIGH POINT = 604.7 40'-0" TENT PORTION 1 HIGH POINT = 603.5 602.7 603.5 AAG LP=600.7 5'-0" 600.5 CONCRETE DRIVEWAY 25'-0" 20'-0" S 12'-0" CONCRETE APPROACH W (S30°01'W 65') 598 3104 HARRIS BLVD N 601.5 BLDG LINE 19'-6" PROPERTY LINE 6 0 0 2 . 7 9 5 = M B SITEPLAN SETBACK PLANE COMPLIANCE EXHIBIT STUART SAMPLEY A R C H I T E C T P 512-771-8856 STUARTSAMPLEYARCHITECT.COM MEMBER OF THE AMERICAN INSTITUTE OF ARCHITECTS GIST E R E D AR C H I T E R S T A T X E T E FO 4-27-2022 E C T SA I D V L B S R R A H 4 0 1 3 A1.1 SITEPLAN - SCALE: 1/8"=1'-0" STUART SAMPLEY A R C H I T E C T P 512-771-8856 STUARTSAMPLEYARCHITECT.COM MEMBER OF THE AMERICAN INSTITUTE OF ARCHITECTS GIST E R E D AR C H I T E R S T A T X E T E FO 4-27-2022 E C T SA I D V L B S R R A H 4 0 1 3 A3.2 REFERENCE FLOORPLANS SCALE: 1/4"=1'-0" 1/4" P.F (TPO) 1/4" P.F (TPO) 10:12 10:12 CHIMNEY SL 3:12 SL SL SL 10:12 5:12 2 1 : 8 1 2 1 : 4 1 1 ROOF PLAN 18:12 14:12 121 OPEN TO CARPORT OPEN TO PORCH 5:12 OPEN TO PORCH 1 FRONT ELEVATION (EAST) 2 SIDE ELEVATION (NORTH) 29'-8" SIDE-GABLED ROOF EXCEPTION BLDG LINE 19'-4" 10'-3" BLDG LINE 30'-0" SIDE-GABLED ROOF EXCEPTION 9'-3" 20'-9" COMPOSITION ROOFING BRICK VENEER CLAD-WOOD WINDOWS 45° 15'-0" 45° 15'-0" COA BLDG HEIGHT STUARTSAMPLEYARCHITECT.COM MEMBER OF THE AMERICAN INSTITUTE OF ARCHITECTS P 512-771-8856 STUART SAMPLEY A R C H I T E C T GIST E R E D AR C H I T E R S T A T X E T E FO 4-27-2022 E C T SA 31'-0" AAG=601.7 I D V L B S R R A H 4 0 1 3 A5.1 EXTERIOR ELEVATIONS SCALE: 1/4"=1'-0" 3 REAR ELEVATION (WEST) 4 SIDE ELEVATION (SOUTH) OPEN TO PORCH OPEN TO CARPORT OPEN TO PORCH FLR-3 21 PLT-2 45° 109 FLR-2 21 PLT-1 15'-0" FLR-1 (601.0) TENT-1=603.5 FLR-3 21 PLT-2 45° FLR-2 21 PLT-1 15'-0" 109 121 FLR-1 TENT-1=603.5