Historic Landmark CommissionJune 1, 2022

C.12.1 - 1909 Kenwood Ave - plans — original pdf

Backup
Thumbnail of the first page of the PDF
Page 1 of 27 pages

ARCHITECTURAL GENERAL A-001 A-002 A-003 A-004 ARCHITECTURE A-100 A-101 A-103 A-104 A-105 A-106 A-108 A-109 A-110 A-201 A-202 A-203 A-204 A-301 A-302 A-303 A-304 A-401 A-402 A-403 A-404 A-405 A-406 A-501 A-601 A-602 A-603 STRUCTURAL S-1 S-3 S-4 S-5 S-6 S-7 COVER VISITABILITY DETAILS SETBACK EXHIBIT BASEMENT EXEMPTION EXHIBIT DEMOLITION PLAN PROPOSED SITE PLAN PRIMARY FLOOR PLANS PRIMARY FLOOR PLANS PRIMARY ROOF PLAN SECONDARY FLOOR PLANS SECONDARY ROOF PLAN PRIMARY RCP SECONDARY RCP PRIMARY - ELEVATIONS PRIMARY - ELEVATIONS SECONDARY - ELEVATIONS SECONDARY - ELEVATIONS PRIMARY - SECTIONS PRIMARY - SECTIONS SECONDARY - SECTIONS SECONDARY - SECTIONS PRIMARY - ENLARGED PLANS PRIMARY - ENLARGED PLANS PRIMARY - INTERIOR ELEVATIONS PRIMARY - INTERIOR ELEVATIONS SECONDARY - INTERIOR ELEVATIONS SECONDARY - INTERIOR ELEVATIONS DETAILS DOOR SCHEDULE WINDOW SCHEDULE FINISHES PRIMARY FOUNDATION PLAN PRIMARY FLOOR FRAMING PLAN PRIMARY FLOOR/ROOF/CEILING FRAMING PLAN PRIMARY ROOF/CEILING FRAMING PLAN SECONDARY FLOOR/ROOF/CEILING FRAMING PLANS SECONDARY ROOF/CEILING FRAMING PLANS 1909 KENWOOD AVE Austin, TX 78704 CODES AND STANDARDS: 1. The term IBC shall apply to the current edition of the International Building Code as amended by the state of Texas. For projects in all other states it shall apply to the current edition of the UBC or IBC as adopted by that state. 2. Local jurisdiction to determine compliance with Chapter 29 (with regard to adjacent facilities) In accordance with their currently adopted edition of the UBC or IBC. 3. This set of plans prepared and submitted for approval under the following code: Building Code: Fire Code: Plumbing Code: Mechanical Code: Electrical Code: Energy Code: 2021 IBC w/ local amendments 2021 IFC w/ local amendments 2021 IPC w/ local amendments 2021 IMC w/ local amendments 2020 NEC w/ local amendments 2021 IECC w/ local amendments 1909 KENWOOD AVE Charles Palmer, KRDB 0.2472 AC (10,768.24 SF) 2963 SF 2 Additional buildings 2 4198 SF-3 Project Summary Project Address: Owner: Site Statistics Gross Site Area: Building Coverage: Residential # of buidings # of units Total Residential SF Zoning Information Property Zoning: Legal Description Parking #of Parking Spaces: 3 Building Height PRIMARY SECONDARY Impervious Cover Allowable Actual LOT 35 *& S 25 FT OF LOT 34 BLK 40 TRAVIS HEIGHTS 1909 KENWOOD AVE DWELLING UNIT AND BUILDING AREA SUMMARY 28' - 11" 31' - 7.5" 4200 3846.5 PROPERTY LOCATION - LOCAL MAP PROPERTY LOCATION - AUSTIN, TEXAS 916 Springdale Rd. Building #5, Suite 101 Austin, TX 78702 512.374.0946 T 512.374.0736 F www.krdb.com DEVELOPER ARCHITECT CHRIS KRAGER KRDB 916 SPRINGDALE RD. BLDG. 5, STE 101, AUSTIN, TX 78702 512.374.0946 CHRIS@KRDB.COM STRUCTURAL CIVIL MEP LANDSCAPING D O O W N E K E V A D O O W N E K 9 0 9 1 4 0 7 8 7 X T , I N T S U A STATUS: CD ISSUE DATE BP Submital 03/16/2022 REVISION SCHEDULE ID NAME DATE COVER A-001 5/6/2022 1:11:36 PM 577' - 0" 577' - 0" 576' - 5 1/2" D S R A 34.5" CLE 35" C UP L E A R 576' - 6" D D S S D S D S D S D S D S DN R angetop O O ven ven D S D S D S DOOR SEAL TRANSITION STRIP . X A M " 2 / 1 . X A M " 8 / 3 1 . X A M " 2 / 1 THRESHOLD . X A M " 2 / 1 EXTERIOR DOOR THRESHOLD 12" = 1'-0" 2 1 Visitability Plan 1/8" = 1'-0" 916 Springdale Rd. Building #5, Suite 101 Austin, TX 78702 512.374.0946 T 512.374.0736 F www.krdb.com DEVELOPER ARCHITECT CHRIS KRAGER KRDB 916 SPRINGDALE RD. BLDG. 5, STE 101, AUSTIN, TX 78702 512.374.0946 CHRIS@KRDB.COM STRUCTURAL CIVIL MEP LANDSCAPING D O O W N E K E V A D O O W N E K 9 0 9 1 4 0 7 8 7 X T , I N T S U A STATUS: CD ISSUE DATE BP Submital 03/16/2022 REVISION SCHEDULE ID NAME DATE VISITABILITY DETAILS A-002 5/6/2022 1:11:38 PM P O R 40' - 0" TIO N 1 ERTY LINE P O PR 0" 0'0 0' 0°0 5.0 N 3 W 7 40' - 0" TIO N 2 R O P S 59°52'32" E 140.00' D S PR OPERTY LINE D S P O R 40' - 0" TIO N 3 D S UP PR O P O FFE: 576'6" SED 2-STO D D S S PR OP FFE: 577'11" OSED 2-STO PR OPERTY LINE RY RESIDEN CE RY RESIDEN R angetop CE O O ven ven D S D S D S DN D S D S N 59°52'32" W 140.00' D S 0" 0'0 0' 0°0 5.0 N 3 W 7 ERTY LINE P O PR 1 Setback Plane Exhibit 1/8" = 1'-0" 916 Springdale Rd. Building #5, Suite 101 Austin, TX 78702 512.374.0946 T 512.374.0736 F www.krdb.com DEVELOPER ARCHITECT CHRIS KRAGER KRDB 916 SPRINGDALE RD. BLDG. 5, STE 101, AUSTIN, TX 78702 512.374.0946 CHRIS@KRDB.COM STRUCTURAL CIVIL MEP LANDSCAPING D O O W N E K E V A D O O W N E K 9 0 9 1 4 0 7 8 7 X T , I N T S U A STATUS: CD ISSUE DATE BP Submital 03/16/2022 REVISION SCHEDULE ID NAME DATE SETBACK EXHIBIT A-003 5/6/2022 1:11:39 PM Tree protection @ 25% CRZ 113 Tree 110 identified as "Imminent Hazard" by arborist provided tree health report. Tree has lost more than 90% of its main stem heartwood. To be demolished. Location of existing Water Meter 670 110 109 108 107 1.4' 336 / / 337 OD AVE (60' R.O.W.) KENW O 671 / / TBM 573.56' Location of Existing Gas Meter 111 EXISTING SINGLE STORY STRUCTURE TO BE DEMOLISHED M G 339 338 340 342 341 Tree protection @ 25% CRZ EXISTING LANDSCAPING TO BE DEMOLISHED 343 344 Location of existing C.O. 345 346 ALLEY (15' R.O.W.) Tree protection @ 25% CRZ 346 398 375 Location of existing C.O. 1 Existing/Demo Plan 1/8" = 1'-0" Existing tree canopy 25% CRZ 50% CRZ Proposed tree Demolished tree 916 Springdale Rd. Building #5, Suite 101 Austin, TX 78702 512.374.0946 T 512.374.0736 F www.krdb.com Type Protected 916 SPRINGDALE RD. BLDG. 5, STE 101, AUSTIN, TX 78702 TREE LEGEND 1/4" = 1'-0" TREE LIST Size (inches) 9 9 18 24 12 20 14 15 13 15 6 20 14 9 6 27 13 18 10 13 6 11 American Elm American Elm Chinese Tallow (Rated) American Elm Pecan Pecan China Berry Box Elder Black Locust HB China Berry (Rated) Pecan Ginko Ginko American Elm American Elm (Rated) American Elm American Elm American Elm American Elm Maple (Rated) Pecan # 107 108 109 110 111 113 336 337 338 339 340 341 342 343 344 345 346 375 376 398 670 671 No No No No No Yes No No No No No Yes No No No Yes No No No No No No DEVELOPER ARCHITECT CHRIS KRAGER KRDB 512.374.0946 CHRIS@KRDB.COM STRUCTURAL CIVIL MEP LANDSCAPING D O O W N E K E V A D O O W N E K 9 0 9 1 4 0 7 8 7 X T , I N T S U A STATUS: CD ISSUE DATE BP Submital 03/16/2022 REVISION SCHEDULE ID NAME DATE DEMOLITION PLAN A-100 5/6/2022 1:11:40 PM D A E LS P P A T C E S 1/2" I,R. W 113 Tree protection @ 25% CRZ UE D AVEN (60' R.O.W.) O O W KEN Location of proposed Water Meter 670 Gutter Curb 6ft privacy fence DN F R O 28' - 1 29/32" M P R O P LIN E 2 A-301 A-201 1 Location of proposed Gas Meter E P LIN 5' - 4 29/32" O R M P O R F A-202 1 S 5 4 0.0 9°5 0' 1 2'3 2" E N 30°00'00" W 75.00' 1 A-303 A-203 111 671 D A E S P L P A T C E S 1/2" .R. W 576' - 4 3/32" 6ft privacy fence 1 - - Deck S E T 25' - 0" B A C K 1 A-301 D S Deck Pool Screened Patio D S Deck E P LIN 5' - 7 21/32" O R M P O R F Primary condenser Location of proposed Electrical Meter DN 2 A-201 4 D S Tree protection @ 25% CRZ 2 A-204 Secondary condenser Location of proposed Gas Meter 8ft privacy fence D S D S D S 2 A-203 Walkable Rooftop Deck Above Garage E-LIN 7' - 6" E T B A E S C K D S DN Deck DN UP 1 A-304 D D S S Location of proposed Electrical Meter, below stair R angetop 2 A-304 O O ven ven 2 D S A-204 A-202 4 5' - 0" K C A B ET S W N 5 1 9°5 4 0.0 2'3 0' 2" D S 345 Location of existing C.O. S 25' OF LOT 34 & LOT 35 Tree protection @ 25% CRZ Location of existing C.O. 375 D 1/2" E P P A A S T C L I.R. W E S 341 5' - 0" K C A B ET S 3 A-201 Overhead E Lines Overhead E Lines Overhead E Lines Existing Power Pole 4' - 8 29/32" OLE M P O R E F C N A DIST G w Drive arage fro ay to 2-C m Alley ar N 30°00'00" W 75.00' F R O 11' - 9 11/16" M P R O P LIN E S E T 5' - 0" B A C K T "X" U T C E S 1 Site Plan 1/8" = 1'-0" 916 Springdale Rd. Building #5, Suite 101 Austin, TX 78702 512.374.0946 T 512.374.0736 F www.krdb.com DEVELOPER ARCHITECT CHRIS KRAGER KRDB 916 SPRINGDALE RD. BLDG. 5, STE 101, AUSTIN, TX 78702 512.374.0946 CHRIS@KRDB.COM STRUCTURAL CIVIL MEP LANDSCAPING D O O W N E K E V A D O O W N E K 9 0 9 1 4 0 7 8 7 X T , I N T S U A STATUS: CD ISSUE DATE BP Submital 03/16/2022 REVISION SCHEDULE ID NAME DATE PROPOSED SITE PLAN A-101 5/6/2022 1:11:41 PM A B C D A-202 1 D.1 D.2 E E.1 F F.1 14' - 2" 14' - 2" 10' - 4 1/2" 2' - 0" 5' - 9 3/4" 6' - 2 1/2" 6' - 4 3/4" 10' - 5 3/4" 23' - 1" 78' - 10 1/4" 39' - 2 1/4" 21' - 0" DN 575' - 3 1/8" New landscape wall 1 A-402 A-201 1 " 1 1 - ' 2 3 2 0 - D " 2 / 1 1 - ' 5 1 " 0 - ' 2 1 " 2 / 1 9 - ' 5 Living Room 6 0 - W 7 0 - W 3 0 - D Deck Screened Porch 10 Powder A-403 7 7 0 - D D-06 D-17 W-10 8 9 UP 576' - 6" 1 0 - D Entry D-04 Closet A-403 1 3 Rangetop Kitchen 2 4 5 A-403 6 DS W-15 Concrete swimming pool w/waterfall edge 573' - 6" 0 1 - D WIC 1 1 - D Planter Bedroom 1 D-12 4 A-404 Bathroom 1 1 6 R @ 0' - 6" 1 2 3 4 5 6 4 1 - W DN D-14 Linen D-13 WC 5 1 - D SD/CO SD/CO 576' - 6" 2 A-201 4 W-11 W-13 D-09 576' - 6" DN 573' - 6" " 6 - ' 0 @ R 6 PRIMARY CONDENSER 571' - 4 11/16" DS 4' - 10 1/2" 6 1 - W 7 1 - W DS DN 2 3 Wetroom 6 1 - D 8 1 - W 9 1 - W 0 2 - W 1 2 - W 2 2 - W 3 2 - W 4 2 - W OvenOven 2 A-202 76' - 5 1/4" DS DS 575' - 5 1/4" DS DS W-30 W-29 W-28 W-27 W-26 DS W-25 DS DS 568' - 8 1/2" 20' - 1" 3' - 0" 3' - 0" 9' - 0" 4' - 6" 6' - 7" 4' - 0" 21' - 2 1/4" 5' - 1" b 1 Primary - Level 1 1/4" = 1'-0" Living Room " 5 - ' 5 1 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 DN D-31 3 A-201 916 Springdale Rd. Building #5, Suite 101 Austin, TX 78702 512.374.0946 T 512.374.0736 F www.krdb.com DEVELOPER ARCHITECT CHRIS KRAGER KRDB 916 SPRINGDALE RD. BLDG. 5, STE 101, AUSTIN, TX 78702 512.374.0946 CHRIS@KRDB.COM STRUCTURAL CIVIL MEP 4 3.2 LANDSCAPING " 1 1 - ' 2 3 " 2 / 1 1 1 - ' 7 1 " 2 / 1 1 1 - ' 4 1 " 2 / 1 0 1 - ' 4 1 " 1 - ' 3 " 4 / 3 9 - ' 1 " 2 / 1 4 - ' 3 " 8 - ' 3 " 8 - ' 3 " 4 / 1 5 - ' 2 3.1 3 2 1 D O O W N E K E V A D O O W N E K 9 0 9 1 4 0 7 8 7 X T , I N T S U A 1 A-401 STATUS: CD ISSUE DATE BP Submital 03/16/2022 REVISION SCHEDULE ID NAME DATE Primary Average Grade Calculation: NW Corner SW Corner NE Corner SE Corner 575' 3 1/8" 574' 9 9/16" 571' 4 11/16" 568' 8 1/2" Average Grade Maximum Height 572' 6" 604' 6" PRIMARY FLOOR PLANS A-103 5/6/2022 1:11:43 PM W-42 W-43 Bedroom 3 DS [No Slope] LANDSCAPING 3 A-201 A B C D D.1 D.2 E A-202 1 E.1 F F.1 16' - 7" 16' - 8 1/2" 7' - 10 1/2" 12' - 1" 4' - 6" 9' - 5 1/4" 6' - 0" 6' - 0" 10' - 3" 3' - 7 3/4" 4' - 0" 3' - 5 1/2" 5' - 7 1/4" 78' - 10 1/4" 37' - 8 1/4" 6' - 0" " 8 - ' 7 " 8 - ' 7 3.2 3.1 " 1 1 - ' 2 3 " 3 - ' 5 2 " 4 - ' 2 " 8 - ' 9 " 2 - ' 2 " 2 / 1 4 - ' 3 " 2 / 1 1 1 - ' 2 " 9 - ' 4 3 2 1 3 3 - W 2 3 - W 1 3 - W A-201 1 Perferated metal D-20 Bedroom 2 4 3 - W 5 3 - W 9 1 - D D-21 D-22 9 2 - D 6 8 A-404 5 WIC W-36 W-37 W-38 W-39 W-13 587' - 6" DN 585' - 6" Bathroom 3 9 12 A-404 10 0 3 - D 6 2 - D A-404 7 Bathroom 2 19 R @ 0' - 6 15/16" DN 587' - 6" Loft Laundry WIC 5 2 - D Bedroom 4 DS W-53 DS DS W-52 W-51 W-50 W-49 W-48 Location of tankless water heater W-47 1 4 - W 0 4 - W 4 2 A-201 SD/CO D-23 D-27 SD/CO " 0 - ' 2 " 0 1 - ' 8 " 0 - ' 4 " 0 1 - ' 4 1 8 2 - D DS 2 A-202 WIC 4 2 - D Wetroom 3 11 4 4 - W 5 4 - W 6 4 - W DS 13' - 11" 6' - 9 1/2" 1' - 9 1/2" 3' - 0" 3' - 0" 9' - 7" 6' - 0" 4' - 10 3/4" 5' - 6 1/2" 4' - 1" 2' - 2" 10' - 2 15/32" 7' - 10 1/2" 70' - 11 3/4" 78' - 10 1/4" 2' - 9 1/2" 5' - 1" A B C D D.1 D.2 E E.1 F F.1 1 Primary - Level 2 1/4" = 1'-0" " 8 - ' 2 " 8 - ' 2 " 5 - ' 3 1 " 0 1 - ' 5 " 3 - ' 3 " 0 - ' 4 " 9 - ' 3 " 1 1 - ' 2 3 " 3 - ' 0 3 4 3.2 3.1 3 2 1 916 Springdale Rd. Building #5, Suite 101 Austin, TX 78702 512.374.0946 T 512.374.0736 F www.krdb.com DEVELOPER ARCHITECT CHRIS KRAGER KRDB 916 SPRINGDALE RD. BLDG. 5, STE 101, AUSTIN, TX 78702 512.374.0946 CHRIS@KRDB.COM STRUCTURAL CIVIL MEP D O O W N E K E V A D O O W N E K 9 0 9 1 4 0 7 8 7 X T , I N T S U A STATUS: CD ISSUE DATE BP Submital 03/16/2022 REVISION SCHEDULE ID NAME DATE Primary Average Grade Calculation: NW Corner SW Corner NE Corner SE Corner 575' 3 1/8" 574' 9 9/16" 571' 4 11/16" 568' 8 1/2" Average Grade Maximum Height 572' 6" 604' 6" PRIMARY FLOOR PLANS A-104 5/6/2022 1:11:45 PM A B C D D.1 D.2 E E.1 F F.1 A-202 1 Downspout Downspout " 0 - ' 1 / " 4 / 1 1/4" / 1'-0" Downspout 3 A-201 4 3.2 CIVIL MEP 3.1 LANDSCAPING A-201 1 2 A-201 4 " 0 - ' 1 / " 4 / 1 W-57 " 0 - ' 1 / " 8 / 1 1/8" / 1'-0" Downspout Downspout Downspout Downspout A 1 Primary - Roof Plan B 1/4" = 1'-0" C D D.1 D.2 E E.1 F F.1 A-204 4 916 Springdale Rd. Building #5, Suite 101 Austin, TX 78702 512.374.0946 T 512.374.0736 F www.krdb.com DEVELOPER ARCHITECT CHRIS KRAGER KRDB 916 SPRINGDALE RD. BLDG. 5, STE 101, AUSTIN, TX 78702 512.374.0946 CHRIS@KRDB.COM STRUCTURAL 3 2 1 D O O W N E K E V A D O O W N E K 9 0 9 1 4 0 7 8 7 X T , I N T S U A STATUS: CD ISSUE DATE BP Submital 03/16/2022 REVISION SCHEDULE ID NAME DATE PRIMARY ROOF PLAN A-105 5/6/2022 1:11:45 PM " 3 - ' 9 1 " 3 - ' 9 1 " 3 - ' 9 1 - - Bedroom I II 5' - 3" 5' - 3" 25' - 5" 20' - 2" 20' - 2" Laundry - - Closet - - - 2 A-204 20' - 2" 20' - 2" 5' - 3" b c d e f 39' - 7" 10' - 5" Living Room Screened Porch 2 A-203 577' - 0" *Measured at grade Bathroom Porch Office Kitchen 576' - 6 3/16" Location of tankless water heater 2 A-204 25' - 5" b c e f 14' - 2" 10' - 5" 50' - 0" d 2 Secondary - Level 2 1/4" = 1'-0" I II " 3 - ' 9 1 " 3 - ' 9 1 A-203 1 - - 1 Secondary - Level 1 1/4" = 1'-0" A-204 4 A-204 4 2 A-203 " 3 - ' 9 1 " 3 - ' 9 1 DS DS DS 570' - 3 7/16" 568' - 10 3/8" DS 916 Springdale Rd. Building #5, Suite 101 Austin, TX 78702 512.374.0946 T 512.374.0736 F www.krdb.com DEVELOPER ARCHITECT CHRIS KRAGER KRDB 916 SPRINGDALE RD. BLDG. 5, STE 101, AUSTIN, TX 78702 512.374.0946 CHRIS@KRDB.COM STRUCTURAL CIVIL MEP LANDSCAPING D O O W N E K E V A D O O W N E K 9 0 9 1 4 0 7 8 7 X T , I N T S U A STATUS: CD ISSUE DATE BP Submital 03/16/2022 REVISION SCHEDULE ID NAME DATE Secondary Average Grade Calculation: NW Corner SW Corner NE Corner SE Corner 574' 8 25/32" 574' 11 7/8" 568' 8 5/32" 568' 10 3/8" Average Grade Maximum Height 572' 0" 604' 0" SECONDARY FLOOR PLANS A-106 5/6/2022 1:11:46 PM Downspout A-204 4 Downspout DS " 0 - ' 1 / " 1 1 " 0 - ' 1 / " 1 1 2 A-203 " 3 - ' 9 1 5' - 3" 20' - 2" Downspout 14' - 2" 10' - 5" Downspout DS b c d e f I II - - SD/CO " 0 - ' 1 / " 1 1 " 0 - ' 1 / " 1 1 2 A-204 1 Secondary - Roof Plan 1/4" = 1'-0" 916 Springdale Rd. Building #5, Suite 101 Austin, TX 78702 512.374.0946 T 512.374.0736 F www.krdb.com DEVELOPER ARCHITECT CHRIS KRAGER KRDB 916 SPRINGDALE RD. BLDG. 5, STE 101, AUSTIN, TX 78702 512.374.0946 CHRIS@KRDB.COM STRUCTURAL CIVIL MEP LANDSCAPING D O O W N E K E V A D O O W N E K 9 0 9 1 4 0 7 8 7 X T , I N T S U A STATUS: CD ISSUE DATE BP Submital 03/16/2022 REVISION SCHEDULE ID NAME DATE SECONDARY ROOF PLAN A-108 5/6/2022 1:11:47 PM DS DS Ceiling Height: 11' 0" Ceiling Height: 11' 0" D SD/CO SD/CO P DS D D SD/CO Ceiling Height: 9' 5" 1 Primary - RCP Level 1 1/4" = 1'-0" SD/CO D D Ceiling Height: 9' 5" Ceiling Height: 10' 0" D D D Ceiling Height: 9' 5" P GFI P P Ceiling Height: 11' 0" Ceiling Height: 9' 5" D3 Connects to Chandelier Above SD/CO Rangetop L L OvenOven L L DS DS DS DS DS DS D3 SD/CO SD/CO D GFI GFI D D D SD/CO D SD/CO D D 3 D D D D I F G I F G I F G W-57 Connects to Switch Below D3 D3 DS DS DS DS DS 2 Primary - RCP Level 2 1/4" = 1'-0" DS ELECTRICAL LEGEND TYPE DESCRIPTION COMMENTS C P F V D 3 GFCI WP 240V 8" RECESSED LED CAN PENDANT EXTERIOR WALL MOUNTED FIXTURE INTERIOR WALL MOUNTED FIXTURE L UNDER COUNTER LIGHTING CEILING FAN SINGLE POWER SWITCH DIMMER POWER SWITCH 3-WAY POWER SWITCH DUPLEX POWER OUTLET GFCI DUPLEX POWER OUTLET WEATHER PROOF DUPLEX POWER OUTLET 240V DUPLEX POWER OUTLET FLOOR MOUNTED POWER OUTLET TV WH TV/COAX CABLE OUTLET TANKLESS WATER HEATER ELECTRICAL POWER PANEL D O O W N E K E V A D O O W N E K 9 0 9 1 4 0 7 8 7 X T , I N T S U A 916 Springdale Rd. Building #5, Suite 101 Austin, TX 78702 512.374.0946 T 512.374.0736 F www.krdb.com DEVELOPER ARCHITECT CHRIS KRAGER KRDB 916 SPRINGDALE RD. BLDG. 5, STE 101, AUSTIN, TX 78702 512.374.0946 CHRIS@KRDB.COM STRUCTURAL CIVIL MEP LANDSCAPING STATUS: CD ISSUE DATE BP Submital 03/16/2022 REVISION SCHEDULE ID NAME DATE PRIMARY RCP A-109 5/6/2022 1:11:48 PM 3 D D P SD I F G 2 Secondary - RCP Level 2 1/4" = 1'-0" 1 Secondary - RCP Level 1 1/4" = 1'-0" D3 D To Lights Below L GFI L GFI L L L GFI L SD SD/CO D D SD SD/CO P DS DS ELECTRICAL LEGEND TYPE DESCRIPTION COMMENTS C P F V D 3 GFCI WP 240V 8" RECESSED LED CAN PENDANT EXTERIOR WALL MOUNTED FIXTURE INTERIOR WALL MOUNTED FIXTURE L UNDER COUNTER LIGHTING CEILING FAN SINGLE POWER SWITCH DIMMER POWER SWITCH 3-WAY POWER SWITCH DUPLEX POWER OUTLET GFCI DUPLEX POWER OUTLET WEATHER PROOF DUPLEX POWER OUTLET 240V DUPLEX POWER OUTLET FLOOR MOUNTED POWER OUTLET TV WH TV/COAX CABLE OUTLET TANKLESS WATER HEATER ELECTRICAL POWER PANEL 916 Springdale Rd. Building #5, Suite 101 Austin, TX 78702 512.374.0946 T 512.374.0736 F www.krdb.com DEVELOPER ARCHITECT CHRIS KRAGER KRDB 916 SPRINGDALE RD. BLDG. 5, STE 101, AUSTIN, TX 78702 512.374.0946 CHRIS@KRDB.COM STRUCTURAL CIVIL MEP LANDSCAPING D O O W N E K E V A D O O W N E K 9 0 9 1 4 0 7 8 7 X T , I N T S U A STATUS: CD ISSUE DATE BP Submital 03/16/2022 REVISION SCHEDULE ID NAME DATE SECONDARY RCP A-110 5/6/2022 1:11:48 PM 1st M c M ansion T ent Trellis over terrace T.O.R. 599' - 6" 604' - 0" 32'0" Height Restriction, Ref. to Average Grade Calculations on A-103 and A-104 32'0" Height Restriction, Ref. to Average Grade Calculations on A-103 and A-104 604' - 0" STC2 Windows behind perforated metal screen W-56 W-55 W-54 Gutter Downspout Perforated metal screen mounted within box, wrapped in STC2 W-33 W-32 W-31 W-46 W-45 STC2 W-44 2 n d M c M a n sio n T e n t 916 Springdale Rd. Building #5, Suite 101 Austin, TX 78702 512.374.0946 T 512.374.0736 F www.krdb.com T.O.R. 599' - 6" DEVELOPER W-05 W-04 W-03 W-02 D-02 W-01 D-01 Metal Privacy Screen W-23 W-21 W-19 W-18 Perforated CMU block fence W-24 W-22 W-20 D-16 W-17 STC1 W-16 Average Grade, Ref. to Average Grade Calculations on A-103 and A-104 ? Average Grade, Ref. to Average Grade Calculations on A-103 and A-104 " 0 - ' 2 1 " 0 - ' 2 " 0 - ' 9 " 0 - ' 3 " 6 - ' 9 LEVEL 2.0 587' - 6" LEVEL 2.1 585' - 6" LEVEL 1.0 576' - 6" LEVEL 1.1 573' - 6" Garage 564' - 0" 1 PRIMARY - WEST ELEVATION 1/4" = 1'-0" 3 PRIMARY - EAST ELEVATION 1/4" = 1'-0" " 0 - ' 2 1 " 0 - ' 2 " 0 - ' 9 " 0 - ' 3 " 6 - ' 9 LEVEL 2.0 587' - 6" LEVEL 2.1 585' - 6" LEVEL 1.0 576' - 6" LEVEL 1.1 573' - 6" Garage 564' - 0" ARCHITECT CHRIS KRAGER KRDB 916 SPRINGDALE RD. BLDG. 5, STE 101, AUSTIN, TX 78702 512.374.0946 CHRIS@KRDB.COM STRUCTURAL CIVIL MEP LANDSCAPING D O O W N E K E V A D O O W N E K 9 0 9 1 4 0 7 8 7 X T , I N T S U A STATUS: CD ISSUE DATE BP Submital 03/16/2022 REVISION SCHEDULE ID NAME DATE Terrace Trellis n t e s t T 1 n t e d T n 2 n t e d T r 3 D-32 STC2 W-41 W-40 B1 W-14 D-10 T.O.R. 599' - 6" LEVEL 2.0 587' - 6" LEVEL 2.1 585' - 6" LEVEL 1.0 576' - 6" LEVEL 1.1 573' - 6" STC2 T.O.R. 599' - 6" W-35 W-34 W-09 W-08 ? D-03 W-07 W-06 LEVEL 2.0 587' - 6" LEVEL 2.1 585' - 6" LEVEL 1.0 576' - 6" LEVEL 1.1 573' - 6" PRIMARY COURTYARD - EAST ELEVATION 1/4" = 1'-0" 2 PRIMARY COURTYARD - WEST ELEVATION 1/4" = 1'-0" 4 MCMANSION ORDINANCE NOTES IF SUBJECT TO SUBCHAPTER F-- A SEPARATE EXHIBIT MUST BE SUBMITTED SHOWING TOPOGRAPHIC ELEVATIONS ON 1- FOOT INTERVALS ON THE PROPERTY, INCLUDING THE TOP OF FOUNDATION SPOT ELEVATION AND INTERSECTIONS OF THE PROPERTY BOUNDARY WITH THE BUILDING LINE SEGMENTS PER SUBCHAPTER F, SECTION 2.6. ALL TOPOGRAPHIC INFORMATION MUST BE PREPARED AND SEALED BY A TEXAS- REGISTERED PROFESSIONAL LAND SURVEYOR. Brick, Soldier Course Stone-ADU B1 B2 CONC3 Concrete - Cast-in-Place Concrete GYP STC1 STC2 TB1 TB3 TW1 Gypsum Wall Board Stucco-Grey Stucco-White Tile-Backsplash-1-Bathroom 1 Tile-Backsplash-3-Bathroom 3 Tile-Wall-9- Short Stacked Green PRIMARY - ELEVATIONS A-201 5/6/2022 1:11:57 PM 604' - 0" 32'0" Height Restriction, Ref. to Average Grade Calculations on A-103 and A-104 STC2 W-39 W-38 W-37 W-36 W-43 W-42 STC2 Perforated metal screen mounted within box, wrapped in STC2 D-20 Guardrail, 4" max. opening DEVELOPER STC2 K C A B T E S T N O R F STC2 B1 STC1 D-09 W-15 W-13 W-12 W-11 Screened Patio B1 Average Grade, Ref. to Average Grade Calculations on A-103 and A-104 " 0 - ' 2 1 " 0 - ' 2 " 0 - ' 9 " 0 - ' 3 " 6 - ' 9 PRIMARY - NORTH ELEVATION 1/4" = 1'-0" 1 604' - 0" 32'0" Height Restriction, Ref. to Average Grade Calculations on A-103 and A-104 K C A B T E S T N O R F Perforated metal screen mounted within box, wrapped in STC2 STC2 W-53 W-52 W-51 W-50 Downspout STC2 W-47 W-49 W-48 STC2 STC1 B1 Metal privacy screen W-30 W-29 W-28 W-27 W-26 W-25 Guardrail, 4" max. opening T.O.R. 599' - 6" LEVEL 2.0 587' - 6" LEVEL 2.1 585' - 6" LEVEL 1.0 576' - 6" LEVEL 1.1 573' - 6" Garage 564' - 0" T.O.R. 599' - 6" B-T.O.P. 594' - 5" LEVEL 2.0 587' - 6" LEVEL 2.1 585' - 6" LEVEL 1.0 576' - 6" LEVEL 1.1 573' - 6" " 1 - ' 5 " 1 1 - ' 6 " 0 - ' 2 " 0 - ' 9 " 0 - ' 3 " 6 - ' 9 916 Springdale Rd. Building #5, Suite 101 Austin, TX 78702 512.374.0946 T 512.374.0736 F www.krdb.com ARCHITECT CHRIS KRAGER KRDB 916 SPRINGDALE RD. BLDG. 5, STE 101, AUSTIN, TX 78702 512.374.0946 CHRIS@KRDB.COM STRUCTURAL CIVIL MEP LANDSCAPING INTERIM FOR DE A S REVIEW ONLY RK I R C I H A R H E R T G T E C S I G E R E R C T THIS DOCUMENT IS INCOMPLETE AND CANNOT BE USED FOR REGULATORY 170 5 APPROVAL, PERMITTING, FO T BIDDING OR CONSTRUCTION. S A E T 2 A X S T E ARCHITECT: Chris R. Krager ARCHITECT REG. NO: 20715 D O O W N E K E V A D O O W N E K 9 0 9 1 4 0 7 8 7 X T , I N T S U A STATUS: CD ISSUE DATE BP Submital 03/16/2022 REVISION SCHEDULE ID NAME DATE Garage 564' - 0" Brick, Soldier Course Stone-ADU B1 B2 CONC3 Concrete - Cast-in-Place Concrete GYP STC1 STC2 TB1 TB3 TW1 Gypsum Wall Board Stucco-Grey Stucco-White Tile-Backsplash-1-Bathroom 1 Tile-Backsplash-3-Bathroom 3 Tile-Wall-9- Short Stacked Green PRIMARY - ELEVATIONS A-202 5/6/2022 1:12:04 PM Average Grade, Ref. to Average Grade Calculations on A-103 and A-104 PRIMARY - SOUTH ELEVATION 1/4" = 1'-0" 2 F ir s t M c m a n sio n T e n t 32'0" Height Restriction, Ref. to Average Grade Calculations on A-106 and A-107 604' - 0" 32'0" Height Restriction, Ref. to Average Grade Calculations on A-106 and A-107 604' - 0" S econd M c m ansion T ent First M c m ansion T ent Brick Parapet Roofline Roofline " 6 - ' 5 Awning B-T.O.P. 594' - 5" B-LEVEL 2 588' - 11" B-T.O.P. 594' - 5" B-LEVEL 2 588' - 11" " 6 - ' 5 Screen for porch B-LEVEL 1 577' - 11" B-LEVEL 1 577' - 11" B-LEVEL -1 569' - 5" B-LEVEL -1 569' - 5" SECONDARY - WEST ELEVATION 1/4" = 1'-0" 1 SECONDARY - EAST ELEVATION 1/4" = 1'-0" 2 916 Springdale Rd. Building #5, Suite 101 Austin, TX 78702 512.374.0946 T 512.374.0736 F www.krdb.com DEVELOPER ARCHITECT CHRIS KRAGER KRDB 916 SPRINGDALE RD. BLDG. 5, STE 101, AUSTIN, TX 78702 512.374.0946 CHRIS@KRDB.COM STRUCTURAL CIVIL MEP LANDSCAPING D O O W N E K E V A D O O W N E K 9 0 9 1 4 0 7 8 7 X T , I N T S U A STATUS: CD ISSUE DATE BP Submital 03/16/2022 REVISION SCHEDULE ID NAME DATE Brick, Soldier Course Stone-ADU B1 B2 CONC3 Concrete - Cast-in-Place Concrete GYP STC1 STC2 TB1 TB3 TW1 Gypsum Wall Board Stucco-Grey Stucco-White Tile-Backsplash-1-Bathroom 1 Tile-Backsplash-3-Bathroom 3 Tile-Wall-9- Short Stacked Green SECONDARY - ELEVATIONS A-203 5/6/2022 1:12:08 PM Brick Parapet Roofline 32'0" Height Restriction, Ref. to Average Grade Calculations on A-106 and A-107 604' - 0" SECONDARY - SOUTH ELEVATION 1/4" = 1'-0" 2 32'0" Height Restriction, Ref. to Average Grade Calculations on A-106 and A-107 604' - 0" Brick Parapet Roofline 916 Springdale Rd. Building #5, Suite 101 Austin, TX 78702 512.374.0946 T 512.374.0736 F www.krdb.com DEVELOPER ARCHITECT CHRIS KRAGER KRDB 916 SPRINGDALE RD. BLDG. 5, STE 101, AUSTIN, TX 78702 512.374.0946 CHRIS@KRDB.COM STRUCTURAL CIVIL MEP LANDSCAPING D O O W N E K E V A D O O W N E K 9 0 9 1 4 0 7 8 7 X T , I N T S U A STATUS: CD ISSUE DATE BP Submital 03/16/2022 REVISION SCHEDULE ID NAME DATE B-T.O.P. 594' - 5" B-LEVEL 2 588' - 11" B-LEVEL 1 577' - 11" B-LEVEL -1 569' - 5" B-T.O.P. 594' - 5" B-LEVEL 2 588' - 11" B-LEVEL 1 577' - 11" B-LEVEL -1 569' - 5" SECONDARY - NORTH ELEVATION 1/4" = 1'-0" 4 Brick, Soldier Course Stone-ADU B1 B2 CONC3 Concrete - Cast-in-Place Concrete GYP STC1 STC2 TB1 TB3 TW1 Gypsum Wall Board Stucco-Grey Stucco-White Tile-Backsplash-1-Bathroom 1 Tile-Backsplash-3-Bathroom 3 Tile-Wall-9- Short Stacked Green SECONDARY - ELEVATIONS A-204 5/6/2022 1:12:14 PM Frame out for metal screen Metal screen GYP GYP GYP ? " 6 - ' 9 " 6 - ' 9 D-21 D-22 W-36 W-37 W-38 " 0 - ' 1 1 W-39 GYP GYP ? " 6 - ' 9 GYP " 0 - ' 9 GYP D-06 " 2 3 / 7 8 - ' 6 D-17 GYP " 0 - ' 9 W-10 D-09 W-11 W-13 GYP GYP GYP " 4 / 3 1 1 - ' 0 1 GYP 1 MAIN HOUSE - SECTION 1 1/4" = 1'-0" GYP GYP D-20 W-36 W-37 W-38 W-39 ? ? D-23 GYP GYP Built-in custom cabinetry Screened Porch D-09 W-11 W-13 GYP GYP GYP 2 MAIN HOUSE - SECTION 2 1/4" = 1'-0" 7' - 6" " 0 - ' 1 R 1 5' - 0" " 6 - ' 9 15' - 0" ? T.O.R. 599' - 6" 4' - 0" LEVEL 2.0 587' - 6" LEVEL 2.1 585' - 6" 5' - 0" R 1 LEVEL 1.0 576' - 6" LEVEL 1.1 573' - 6" Garage 564' - 0" 7' - 6" 4' - 0" R 1 5' - 0" " 5 ' - 0 R 1 15' - 0" " 0 - ' 0 4 " 0 - ' 1 " 6 - ' 9 " 6 - ' 9 2 D-31 " 0 - ' 3 916 Springdale Rd. Building #5, Suite 101 Austin, TX 78702 512.374.0946 T 512.374.0736 F www.krdb.com DEVELOPER ARCHITECT CHRIS KRAGER KRDB 916 SPRINGDALE RD. BLDG. 5, STE 101, AUSTIN, TX 78702 512.374.0946 CHRIS@KRDB.COM STRUCTURAL CIVIL MEP LANDSCAPING D O O W N E K E V A D O O W N E K 9 0 9 1 4 0 7 8 7 X T , I N T S U A STATUS: CD ISSUE DATE BP Submital 03/16/2022 REVISION SCHEDULE ID NAME DATE PRIMARY - SECTIONS A-301 5/6/2022 1:12:17 PM 4 3.2 3.1 3 2 W-57 1 T.O.R. 599' - 6" W-54 W-55 W-56 GYP GYP STC2 D-28 W-41 W-40 D-30 4 3.2 3.1 3 2 1 T.O.R. 599' - 6" LANDSCAPING W-41 W-40 STC2 GYP D-30 GYP B1 W-14 W-21 W-22 B1 B1 W-18 W-19 W-21 W-23 W-14 D-10 D-10 D-16 W-20 W-22 W-24 LEVEL 2.0 587' - 6" LEVEL 2.1 585' - 6" LEVEL 1.0 576' - 6" LEVEL 1.1 573' - 6" Garage 564' - 0" 1 MAIN HOUSE - SECTION 3 1/4" = 1'-0" 2 MAIN HOUSE - SECTION 4 1/4" = 1'-0" 916 Springdale Rd. Building #5, Suite 101 Austin, TX 78702 512.374.0946 T 512.374.0736 F www.krdb.com DEVELOPER ARCHITECT CHRIS KRAGER KRDB 916 SPRINGDALE RD. BLDG. 5, STE 101, AUSTIN, TX 78702 512.374.0946 CHRIS@KRDB.COM STRUCTURAL CIVIL MEP D O O W N E K E V A D O O W N E K 9 0 9 1 4 0 7 8 7 X T , I N T S U A STATUS: CD ISSUE DATE BP Submital 03/16/2022 REVISION SCHEDULE ID NAME DATE LEVEL 2.0 587' - 6" LEVEL 2.1 585' - 6" LEVEL 1.0 576' - 6" LEVEL 1.1 573' - 6" Garage 564' - 0" Brick, Soldier Course Stone-ADU B1 B2 CONC3 Concrete - Cast-in-Place Concrete GYP STC1 STC2 TB1 TB3 TW1 Gypsum Wall Board Stucco-Grey Stucco-White Tile-Backsplash-1-Bathroom 1 Tile-Backsplash-3-Bathroom 3 Tile-Wall-9- Short Stacked Green PRIMARY - SECTIONS A-302 5/6/2022 1:12:19 PM b c d e f Steel Column Downspout 1 ADU - SECTION 1 1/4" = 1'-0" f e d c b 916 Springdale Rd. Building #5, Suite 101 Austin, TX 78702 512.374.0946 T 512.374.0736 F www.krdb.com DEVELOPER ARCHITECT CHRIS KRAGER KRDB 916 SPRINGDALE RD. BLDG. 5, STE 101, AUSTIN, TX 78702 512.374.0946 CHRIS@KRDB.COM STRUCTURAL CIVIL MEP LANDSCAPING D O O W N E K E V A D O O W N E K 9 0 9 1 4 0 7 8 7 X T , I N T S U A STATUS: CD ISSUE DATE BP Submital 03/16/2022 REVISION SCHEDULE ID NAME DATE B-T.O.P. 594' - 5" B-LEVEL 2 588' - 11" B-LEVEL 1 577' - 11" B-LEVEL -1 569' - 5" B-T.O.P. 594' - 5" B-LEVEL 2 588' - 11" B-LEVEL 1 577' - 11" B-LEVEL -1 569' - 5" 2 ADU - SECTION 2 1/4" = 1'-0" Brick, Soldier Course Stone-ADU B1 B2 CONC3 Concrete - Cast-in-Place Concrete GYP STC1 STC2 TB1 TB3 TW1 Gypsum Wall Board Stucco-Grey Stucco-White Tile-Backsplash-1-Bathroom 1 Tile-Backsplash-3-Bathroom 3 Tile-Wall-9- Short Stacked Green SECONDARY - SECTIONS A-303 5/6/2022 1:12:20 PM II I II I 1st M C M A N SIO N T E N T 5' - 0" SETBACK E N I L Y T R E P O R P 5' - 0" SETBACK E N I L Y T R E P O R P 1st M C M A N SIO N T E N T 2nd M C M A N SIO N T E N T B-T.O.P. 594' - 5" B-LEVEL 2 588' - 11" B-LEVEL 1 577' - 11" B-LEVEL -1 569' - 5" 1 ADU - SECTION 3 1/4" = 1'-0" 2 ADU - SECTION 4 1/4" = 1'-0" 916 Springdale Rd. Building #5, Suite 101 Austin, TX 78702 512.374.0946 T 512.374.0736 F www.krdb.com DEVELOPER ARCHITECT CHRIS KRAGER KRDB 916 SPRINGDALE RD. BLDG. 5, STE 101, AUSTIN, TX 78702 512.374.0946 CHRIS@KRDB.COM STRUCTURAL CIVIL MEP LANDSCAPING D O O W N E K E V A D O O W N E K 9 0 9 1 4 0 7 8 7 X T , I N T S U A STATUS: CD ISSUE DATE BP Submital 03/16/2022 REVISION SCHEDULE ID NAME DATE B-T.O.P. 594' - 5" B-LEVEL 2 588' - 11" B-LEVEL 1 577' - 11" B-LEVEL -1 569' - 5" Brick, Soldier Course Stone-ADU B1 B2 CONC3 Concrete - Cast-in-Place Concrete GYP STC1 STC2 TB1 TB3 TW1 Gypsum Wall Board Stucco-Grey Stucco-White Tile-Backsplash-1-Bathroom 1 Tile-Backsplash-3-Bathroom 3 Tile-Wall-9- Short Stacked Green SECONDARY - SECTIONS A-304 5/6/2022 1:12:21 PM 0' - 11 5/8" 17' - 0 3/8" 2' - 4" 16 R @ 0' - 7 1/8" UP 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 LANDSCAPING D-31 Parking Pad 20' - 4" 1 Enlarged Plan - Garage 1/2" = 1'-0" 916 Springdale Rd. Building #5, Suite 101 Austin, TX 78702 512.374.0946 T 512.374.0736 F www.krdb.com DEVELOPER ARCHITECT CHRIS KRAGER KRDB 916 SPRINGDALE RD. BLDG. 5, STE 101, AUSTIN, TX 78702 512.374.0946 CHRIS@KRDB.COM STRUCTURAL CIVIL MEP D O O W N E K E V A D O O W N E K 9 0 9 1 4 0 7 8 7 X T , I N T S U A STATUS: CD ISSUE DATE BP Submital 03/16/2022 REVISION SCHEDULE ID NAME DATE PRIMARY - ENLARGED PLANS A-401 5/6/2022 1:12:22 PM " 0 - ' 3 " 0 - ' 2 " 0 - ' 3 " 0 - ' 2 " 0 - ' 3 " 0 - ' 2 " 0 - ' 3 0' - 0" 21' - 2 1/2" 1' - 9 1/2" Spa [No Slope] 3 3/4" / 1'-0" 5'6" [No Slope] " 2 / 1 6 - ' 0 1 3'6" " 9 - ' 8 " 7 - ' 4 Planter/possible location of pump 20' - 0" 4' - 1 25/32" 1 Enlarged Plan - Pool 1/4" = 1'-0" 1' - 0" 1' - 0" 21' - 0" 19' - 0" " 0 - ' 5 " 6 - ' 5 " 6 - ' 3 2' - 0" 7' - 0" 7' - 0 1/8" 7' - 0" 2 Section-Pool 1/4" = 1'-0" 916 Springdale Rd. Building #5, Suite 101 Austin, TX 78702 512.374.0946 T 512.374.0736 F www.krdb.com DEVELOPER ARCHITECT CHRIS KRAGER KRDB 916 SPRINGDALE RD. BLDG. 5, STE 101, AUSTIN, TX 78702 512.374.0946 CHRIS@KRDB.COM STRUCTURAL CIVIL MEP LANDSCAPING D O O W N E K E V A D O O W N E K 9 0 9 1 4 0 7 8 7 X T , I N T S U A STATUS: CD ISSUE DATE BP Submital 03/16/2022 REVISION SCHEDULE ID NAME DATE PRIMARY - ENLARGED PLANS A-402 5/6/2022 1:12:22 PM D-09 W-11 D-09 W-11 Glass Guardrail DB15-3 B21 B36 DW B15 B15 GYP ? D-07 ? GYP ? 3 - 2 1 B D V VSB30 1 Kitchen-North-a 1/2" = 1'-0" 2 Kitchen-North-b 1/2" = 1'-0" 7 Powder-East 1/2" = 1'-0" 8 Powder-North 1/2" = 1'-0" W-26 W-27 Refrigerator hidden within cabinet Oven W-26 W-27 Range D-06 Refrigerator hidden within cabinet GYP ? GYP ? 3 Kitchen-South-a 1/2" = 1'-0" 4 Kitchen-South-b 1/2" = 1'-0" 9 Powder-South 1/2" = 1'-0" 10 Powder-West 1/2" = 1'-0" Glass Handrail Glass Guardrail 0' - 10 25/32" 5 Kitchen-West 1/2" = 1'-0" 6 Kitchen-East 1/2" = 1'-0" 916 Springdale Rd. Building #5, Suite 101 Austin, TX 78702 512.374.0946 T 512.374.0736 F www.krdb.com DEVELOPER ARCHITECT CHRIS KRAGER KRDB 916 SPRINGDALE RD. BLDG. 5, STE 101, AUSTIN, TX 78702 512.374.0946 CHRIS@KRDB.COM STRUCTURAL CIVIL MEP LANDSCAPING D O O W N E K E V A D O O W N E K 9 0 9 1 4 0 7 8 7 X T , I N T S U A STATUS: CD ISSUE DATE BP Submital 03/16/2022 REVISION SCHEDULE ID NAME DATE Brick, Soldier Course Stone-ADU B1 B2 CONC3 Concrete - Cast-in-Place Concrete GYP STC1 STC2 TB1 TB3 TW1 Gypsum Wall Board Stucco-Grey Stucco-White Tile-Backsplash-1-Bathroom 1 Tile-Backsplash-3-Bathroom 3 Tile-Wall-9- Short Stacked Green PRIMARY - INTERIOR ELEVATIONS A-403 5/6/2022 1:12:27 PM GYP W-16 ? W-17 ? GYP GYP ? ? 6 9 8 1 C U D-13 D-12 1 Bathroom 1-East 1/2" = 1'-0" 2 Bathroom 1-North 1/2" = 1'-0" 3 Bathroom 1-South 1/2" = 1'-0" 4 Bathroom 1-West 1/2" = 1'-0" GYP ? 3 - 5 1 B D V VSB30 VSB30 3 - 5 1 B D V 3 - 5 1 B D V 6 9 8 1 C U ? D-21 W-53 ? GYP D-29 W-31 ? 5 Bathroom 2-East 1/2" = 1'-0" 6 Bathroom 2-North 1/2" = 1'-0" 7 Bathroom 2-South 1/2" = 1'-0" 8 Bathroom 2-West 1/2" = 1'-0" W-44 ? ? UC2496 UC2496 D-26 ? ? ? 9 Bathroom 3-1 1/2" = 1'-0" 10 Bathroom 3-2 1/2" = 1'-0" 11 Bathroom 3-3 1/2" = 1'-0" 12 Bathroom 3-4 1/2" = 1'-0" Brick, Soldier Course Stone-ADU B1 B2 CONC3 Concrete - Cast-in-Place Concrete GYP STC1 STC2 TB1 TB3 TW1 Gypsum Wall Board Stucco-Grey Stucco-White Tile-Backsplash-1-Bathroom 1 Tile-Backsplash-3-Bathroom 3 Tile-Wall-9- Short Stacked Green 916 Springdale Rd. Building #5, Suite 101 Austin, TX 78702 512.374.0946 T 512.374.0736 F www.krdb.com DEVELOPER ARCHITECT CHRIS KRAGER KRDB 916 SPRINGDALE RD. BLDG. 5, STE 101, AUSTIN, TX 78702 512.374.0946 CHRIS@KRDB.COM STRUCTURAL CIVIL MEP LANDSCAPING D O O W N E K E V A D O O W N E K 9 0 9 1 4 0 7 8 7 X T , I N T S U A STATUS: CD ISSUE DATE BP Submital 03/16/2022 REVISION SCHEDULE ID NAME DATE PRIMARY - INTERIOR ELEVATIONS A-404 5/6/2022 1:12:29 PM NO. POSITION Family WIDTH HEIGHT THICKNESS OPERATION WALL THICKNESS SLAB STYLE FINISH TRIM COMMENTS Egress Door DOOR SCHEDULE RESIDENTIAL " 0 - ' 8 " 0 - ' 8 " 8 - ' 6 " 8 - ' 6 " 8 - ' 6 " 0 - ' 8 4' - 0" 8' - 0" 4' - 0" 3' - 0" 2' - 8" 7' - 0" D-01 2' - 0" D-02, D-03, D-09, D-17 D-04, D-05 D-06, D-12, D-28 D-07, D-23, D-27, D-30 D-10 2' - 6" 3' - 0" 3' - 0" 2' - 10" 7' - 0" 2' - 7" DEVELOPER " 8 - ' 6 " 8 - ' 6 " 8 - ' 6 " 0 - ' 8 " 8 - ' 6 " 0 - ' 7 " 8 - ' 6 D-11, D-14 D-13, D-29 D-15, D-31 D-16 D-19, D-25 D-20 D-21, D-22 4' - 6 5/16" 2' - 8" 8' - 0" " 2 3 / 5 3 - ' 8 PRIMARY DOOR TYPES LEGEND " 8 - ' 6 " 8 - ' 6 D-24 D-26 D-32 EGRESS EGRESS No No Yes No No No No No Yes Yes Yes Yes No No No Yes Yes Yes No No No No No Yes No No No No No No No Yes No Yes No Yes No No No Interior ByPass 4' - 0" 6' - 8" 0' - 1 3/8" Interior Exterior Single-Swing Garage Door B-LEVEL 1 D-47 A Garage D-31 D-32 LEVEL 1.1 D-10 D-11 D-12 D-13 D-14 D-15 D-16 LEVEL 1.0 D-01 D-02 D-03 D-04 D-06 D-07 D-09 D-17 D-33 D-56 LEVEL 2.1 D-24 D-25 D-26 D-27 LEVEL 2.0 D-19 D-20 D-21 D-22 D-23 D-28 D-29 D-30 B B-LEVEL 1 D-34 D-40 D-41 D-55 B-LEVEL 2 D-08 D-18 D-37 D-49 D-50 Interior Interior Interior Interior Interior Interior Exterior Interior Interior Interior Interior Interior Interior Interior Interior Interior Interior Interior Interior Interior Interior Interior Exterior Interior Interior Interior Interior Interior Interior Interior Exterior Interior Exterior Interior Exterior Interior Interior Interior Slider Single-Swing Pocket Door Single-Swing Single-Swing Single-Swing Single-Full Lite-Swing Full Light-Pivot Slider Slider ByPass Pocket Door Single-Swing Slider Slider Slider Single-Swing Double Pocket Single-Swing Pocket Door Single-Swing Single-Swing Patio Door-Slider Pocket Door Pocket Door Single-Swing Pocket Door Single-Swing Single-Swing Pocket Door Single-Full Lite-Swing Double Pocket Patio Door-Slider Pocket Door Single-Full Lite-Swing Pocket Door Pocket Door Pocket Door 3' - 0" 8' - 0" 7' - 0" 2' - 0" 3' - 0" 2' - 6" 2' - 0" 3' - 0" 3' - 0" 4' - 0" 8' - 0" 8' - 0" 6' - 0" 3' - 0" 2' - 8" 8' - 0" 8' - 0" 8' - 0" 3' - 0" 2' - 10" 7' - 0" 2' - 8" 2' - 8" 2' - 8" 3' - 0" 2' - 6" 2' - 8" 2' - 10" 3' - 0" 2' - 6" 2' - 8" 2' - 8" 6' - 8" 6' - 8" 8' - 0" 6' - 8" 6' - 8" 6' - 8" 6' - 8" 6' - 8" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 6' - 8" 6' - 8" 6' - 8" 8' - 0" 8' - 0" 8' - 0" 5' - 0" 6' - 8" 7' - 0" 6' - 8" 6' - 8" 6' - 8" 6' - 8" 6' - 8" 6' - 8" 6' - 8" 8' - 0" 6' - 8" 6' - 8" 6' - 8" 3' - 0" 3' - 0" 10' - 4 13/32" 8' - 0" 6' - 8" 8' - 0" 8' - 4 23/32" 8' - 0" 0' - 2" 0' - 1 1/2" 0' - 2" 0' - 2" 0' - 1 3/8" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 1 3/8" 0' - 1 3/8" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 1 3/8" 0' - 1 3/8" 0' - 2" 0' - 1 3/8" 0' - 2" 0' - 2" 0' - 1 3/8" 0' - 2" 0' - 3 15/16" 0' - 2" 0' - 1 3/8" 0' - 2" 0' - 1 3/8" 0' - 1 3/8" 0' - 1 3/8" 8' - 4 13/32" 2' - 10" 2' - 10" 2' - 8" 8' - 4 23/32" 6' - 8" 6' - 8" 6' - 8" 0' - 3 15/16" 0' - 2" 0' - 1 3/8" 0' - 2" THE GENERAL CONTRACTOR SHALL PROVIDE THE FOLLOWING SUBMITTALS IN THE FORM OF SHOP DRAWINGS, PRODUCT CUT SHEETS, AND/OR MATERIAL SAMPLES TO THE PROJECT DESIGNER FOR THE OWNER APPROVAL: 1. METAL FABRICATIONS, METAL FINISHES, AND MATERIAL SAMPLES. 2. SAMPLES OF CONCRETE STAINING COLORS AND FINISHES PRIOR TO STAINING THE FLOOR OWNER TO PROVIDE GENERAL CONTRACTOR WITH A SAMPLE OF THE COLOR/FINISH DESIRED. 3. CABINET SHOP DRAWINGS AND INTERIOR ARCHITECTURAL TRIM DETAILS (UPON THE DISCRETION OF THE PROJECT DESIGNER). 4. GYPSUM BOARD SAMPLES OF WALL TEXTURES/FINISHES. 5. COLORS OF ALL SEALANTS AND CAULKS WHICH WILL BE EXPOSED TO VIEW. 6. WINDOW, DOOR, AND DOOR FRAME SUBMITTALS. 7. DOOR HARDWARE AND HINGES. 8. SOUND SYSTEM SPEAKERS. 9. ALL TOILET AND BATH ACCESSORIES. (ALL ACCESSORIES SHOULD MEET BOBRICK, BRADLEY, OR ASI STANDARDS OR EQUAL). 10. PLUMBING FIXTURES AND TRIM. 11. ELECTRICAL LIGHTING PACKAGE, INCLUDING SWITCHES AND OUTLETS (USE DECORA STYLE ROCKER SWITCHES AND OUTLETS.) VERIFY COLOR AND FINISH WITH PROJECT DESIGNER. 12. FINISH SAMPLES, INCLUDING: ACOUSTICAL CEILING TILE, RUBBER BASE(S), TILE, CARPET, WALL ITSELF. COVERINGS, CORK, ETC. GENERAL NOTES - DOORS 3' - 0" 8' - 0" 3' - 0" 2' - 8" " 8 - ' 6 " 0 - ' 8 " 8 - ' 6 " 8 - ' 6 D-01 D-02, D-03, D-07 D-04, D-13, D-14 D-05, D-08 2' - 10" 2' - 6" 2' - 8" 2' - 6" " 8 - ' 6 " 8 - ' 6 " 8 - ' 6 " 8 - ' 6 SECONDARY DOOR TYPE LEGEND D-09 D-10 D-12 D-15 916 Springdale Rd. Building #5, Suite 101 Austin, TX 78702 512.374.0946 T 512.374.0736 F www.krdb.com ARCHITECT CHRIS KRAGER KRDB 916 SPRINGDALE RD. BLDG. 5, STE 101, AUSTIN, TX 78702 512.374.0946 CHRIS@KRDB.COM STRUCTURAL CIVIL MEP LANDSCAPING D O O W N E K E V A D O O W N E K 9 0 9 1 4 0 7 8 7 X T , I N T S U A STATUS: CD ISSUE DATE BP Submital 03/16/2022 REVISION SCHEDULE ID NAME DATE DOOR SCHEDULE A-601 5/6/2022 1:12:30 PM WINDOW SCHEDULE RESIDENTIAL MARK WIDTH HEIGHT AREA TYPE Comments Egress Tempered 2' - 0" 2' - 0" 4' - 0" 4' - 0" 8' - 0" 8' - 0" Casement Casement HEAD HEIGHT 6' - 11" 6' - 11" 6' - 11" 6' - 11" 6' - 11" 9' - 4" 9' - 4" 6' - 11" 6' - 11" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 6' - 0" 6' - 0" 10' - 0" 10' - 0" 8' - 0" 10' - 0" 8' - 0" 10' - 0" 8' - 0" 10' - 0" 4' - 4 1/2" 4' - 4 1/2" 9' - 0" 9' - 0" 9' - 0" 9' - 6" 9' - 6" 9' - 6" 9' - 6" 9' - 6" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 10' - 10 3/4" 10' - 10 3/4" 10' - 10 3/4" 8' - 0 3/8" 8' - 0" 4' - 6" 4' - 6" 4' - 6" 8' - 0" 8' - 0" 11' - 0" 8' - 0" 8' - 0" 13' - 4" 13' - 4" 13' - 4" 11' - 0" -0' - 6" 11' - 0" 11' - 0" 4' - 6" 8 8 16 5 5 5 5 5 34 34 5 5 29 24 24 24 18 16 9 20 6 7 29 7 29 7 29 24 7 7 27 27 27 43 26 26 38 38 36 36 36 36 16 16 24 24 6 24 24 16 12 12 24 24 24 16 7 7 7 26 1124 15 24 8 8 8 12 12 33 12 12 40 8 8 33 12 33 33 8 319 1459 1' - 4" 1' - 4" 1' - 4" 1' - 4" 1' - 4" 9' - 4" 9' - 4" 1' - 4" 1' - 4" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 3' - 0" 2' - 0" 3' - 0" 4' - 0" 2' - 0" 2' - 0" 8' - 0" 2' - 0" 8' - 0" 2' - 0" 8' - 0" 8' - 0" 1' - 6" 1' - 6" 9' - 0" 9' - 0" 9' - 0" 8' - 8" 8' - 8" 8' - 8" 9' - 6" 9' - 6" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 8' - 0" 8' - 0" 6' - 0" 6' - 0" 3' - 0" 6' - 0" 6' - 0" 8' - 0" 2' - 0" 2' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 1' - 6" 1' - 6" 1' - 6" 4' - 2" 5' - 0" 8' - 0" 4' - 0" 4' - 0" 4' - 0" 6' - 0" 6' - 0" 11' - 0" 8' - 0" 8' - 0" 5' - 0" 5' - 0" 5' - 0" 11' - 0" 1' - 6" 11' - 0" 11' - 0" 4' - 0" W-61 W-68 : 2 A W-01 W-02 W-03 W-04 W-05 W-06 W-07 W-08 W-09 W-10 W-11 W-12 W-13 W-14 W-15 W-16 W-17 W-18 W-19 W-20 W-21 W-22 W-23 W-24 W-25 W-26 W-27 W-28 W-29 W-30 W-31 W-32 W-33 W-34 W-35 W-36 W-37 W-38 W-39 W-40 W-41 W-42 W-43 W-44 W-45 W-46 W-47 W-48 W-49 W-50 W-51 W-52 W-53 W-54 W-55 W-56 W-57 A: 57 B W-58 W-59 W-63 W-64 W-65 W-66 W-67 W-69 W-70 W-71 W-72 W-73 W-74 W-75 W-76 W-77 W-78 W-79 B: 18 Grand total: 77 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 3' - 8" 3' - 8" 4' - 0" 4' - 0" 3' - 8" 3' - 0" 3' - 0" 3' - 0" 6' - 0" 8' - 0" 3' - 0" 5' - 0" 3' - 0" 3' - 8" 3' - 8" 3' - 8" 3' - 8" 3' - 8" 3' - 8" 3' - 0" 4' - 6" 4' - 6" 3' - 0" 3' - 0" 3' - 0" 5' - 0" 3' - 0" 3' - 0" 4' - 0" 4' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 2' - 0" 2' - 0" 4' - 0" 4' - 0" 2' - 0" 4' - 0" 4' - 0" 2' - 0" 6' - 0" 6' - 0" 3' - 0" 3' - 0" 3' - 0" 2' - 0" 4' - 9" 4' - 9" 4' - 9" 6' - 4" 3' - 0" 3' - 0" 2' - 0" 2' - 0" 2' - 0" 2' - 0" 2' - 0" 3' - 0" 1' - 6" 1' - 6" 8' - 0" 1' - 6" 1' - 6" 3' - 0" 8' - 0" 3' - 0" 3' - 0" 2' - 0" Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Horizontal Slider Horizontal Slider Fixed Horizontal Slider Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Horizontal Slider Horizontal Slider Fixed Fixed Fixed Horizontal Slider Horizontal Slider Casement Horizontal Slider Horizontal Slider Fixed Horizontal Slider Horizontal Slider Fixed Fixed Fixed Fixed Fixed Fixed Fixed Skylight Casement Single Hung Single Hung Single Hung Single Hung Single Hung Single Hung Single Hung Fixed Fixed Fixed Fixed-Trapezoid Fixed-Trapezoid Single Hung Fixed-Triangle Single Hung Single Hung Single Hung 1' - 6" ° 0 5 . 0 4 No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No Yes Yes No No No Yes Yes No Yes Yes No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No Yes Yes No No Yes Yes Yes Yes No No No No No No Yes No Yes No Yes Yes No No Yes Yes Yes Yes Yes Yes Yes Yes No No No No No No No No No No No No No No Yes Yes Yes No No No No No No No No No No No No No Yes Yes No No No No No Yes Yes No 3' - 0" 1' - 6" 8' - 0" " 0 - ' 8 " 0 - ' 8 T T " 0 - ' 5 H H " 4 - ' 3 F1 F M O R F " 4 - ' 8 " 6 - ' 3 " 0 - ' 5 H H " 4 - ' 3 F1 F M O R F " 4 - ' 8 96.00° 8' - 0" 1' - 6" 45.00° " 6 - ' 3 H H " 2 3 / 7 2 - ' 7 1 " 2 3 / 7 7 - ' 3 F F M O R F " 8 - ' ' 3 1 H H " 4 - ' 3 1 " 0 - ' 5 F F M O R F " 4 - ' 8 " 0 - ' " 6 0 - ' 8 " 0 - ' 2 2' - 0" 3' - 0" 3' - 0" 5' - 0" 7' - 0" " 0 - ' 8 " 0 - ' 4 " 0 - ' 4 " 0 - ' 8 " 0 - ' 5 " 0 - ' 3 " 0 - ' 8 " 0 - ' 2 " 7 - ' "7 7 - ' 5 " 0 - ' 2 " 7 - ' "7 7 - ' 5 SECONDARY WINDOW LEGEND T 1. LAP PAN FLASHING OVER FLAP OF HOUSEWRAP. THEN SET WINDOW INTO SEALANT ON TOP AND TWO SIDES. 2. INSTALL SIDE SPLINES, THEN HEAD FLASHING. LATER WEAVE HOUSEWRAP UNDER FLAP AND TAPE ALONG SIDE JAMBS. BED WINDOW IN SEALANT AT TOP AND SIDES. PAN FLASHING OF MOLDABLE PEEL- AND-STICK MEMBRANE PLASTIC HOUSEWRAP EXTENDS DOWN TO SILL OR BOTTOM OF BAND JOIST. HORIZONTAL PEEL-AND-STICK FLASHING SEALED TO SHEATHING OVER VERTICAL PEEL-AND-STICK FLASHING VERTICAL PEEL-AND-STICK FLASHING SEALED TO SHEATHING @ SIDES LAYER FLAP OVER HOUSEWRAP WHEN INSTALLED DEVELOPER 916 Springdale Rd. Building #5, Suite 101 Austin, TX 78702 512.374.0946 T 512.374.0736 F www.krdb.com " 4 - ' 1 " 4 - ' 9 " 0 - ' 8 " 0 - ' 2 " 0 - ' 8 " 0 - ' 0 1 1 WINDOW FLASHING DETAIL 1/2" = 1'-0" 4' - 0" 3' - 8" 3' - 8" 3' - 0" 6' - 0" 8' - 0" 5' - 0" 5' - 0" " 4 - ' 9 " 0 - ' 8 " 0 - ' 8 T T T W-01, W-02, W-03, W-04, W-05, W-08, W-09 W-06, W-07 W-10, W-20, W-22, W-24 W-11, W-12, W-13, W-50, W-51, W-52 3' - 0" 4' - 6" 3' - 0" 5' - 0" 3' - 0" 4' - 0" 6' - 0" W-14 W-15 W-16 W-17 W-18 " 0 - ' 2 " 0 - ' 8 " 0 - ' 0 1 " 0 - ' 6 " 0 - ' 3 " 0 - ' 3 " 0 - ' 6 " 0 - ' 4 " 0 - ' 2 W-19, W-21, W-23 W-26, W-27 W-28, W-29, W-30 W-31 W-32, W-33 W-34, W-35 W-36 4' - 0" 5' - 10 1/4" 4' - 9" " 0 - ' 9 " 8 - ' 8 " 6 - ' 9 T " 0 1 - ' 0 " 6 - ' 9 " 0 - ' 8 " 0 - ' 6 " 0 - ' 2 T T T " 8 - ' 8 " 6 - ' 9 " 0 1 - ' 0 6' - 5" " 0 - ' 3 " 0 - ' 5 " 0 - ' 8 " 6 - ' 1 " 4 / 3 4 - ' 9 " 4 / 3 0 1 - ' 0 1 " 0 - ' 2 " 0 - ' "8 0 - ' 6 " 3 - ' 4 " 0 - ' 0 1 " 0 - ' 8 " 0 - ' 2 T " 2 / 1 4 - ' 4 " 6 - ' 1 " 2 / 1 0 1 - ' 2 W-25 2' - 0" " 0 - ' 3 " 0 - ' 5 " 0 - ' 8 " 0 - ' 2 " 0 - ' 6 " 0 - ' 8 W-42, W-43, W-45, W-46 W-44 W-48, W-49 W-54, W-55, W-56 (IN PLAN FOR SKYLIGHTS) W-57 PRIMARY WINDOW LEGEND ARCHITECT CHRIS KRAGER KRDB 916 SPRINGDALE RD. BLDG. 5, STE 101, AUSTIN, TX 78702 512.374.0946 CHRIS@KRDB.COM STRUCTURAL CIVIL MEP LANDSCAPING D O O W N E K E V A D O O W N E K 9 0 9 1 4 0 7 8 7 X T , I N T S U A STATUS: CD ISSUE DATE BP Submital 03/16/2022 REVISION SCHEDULE ID NAME DATE WINDOW SCHEDULE A-602 5/6/2022 1:12:31 PM ROOM FLOOR FINISH WALL FINISH CEILING FINISH AREA COMMENTS MODEL MANUFACTURER WIDTH HEIGHT DEPTH Count NOTES COST Adornus Ballagio Adornus Ballagio Adornus Ballagio Adornus Ballagio Adornus Bellagio Adornus Bellagio DB15-3 DB18-3 Adornus Bellagio SB36 Adornus Ballagio Adornus Bellagio UC2496 W361524-UP Adornus Bellagio A B12 B15 B21 B36 DB15-3 OC3096 SP3696 UC1896 UC2496 VDB12-3 VDB15-3 VSB30 W1842 W2442 B UC1896 VDB12-3 VSB30 Grand total: 47 Adornus Bellagio Adornus Bellagio Adornus Bellagio Adornus Bellagio Adornus Bellagio Adornus Bellagio Adornus Bellagio Adornus Bellagio Adornus Bellagio Adornus Bellagio 1' - 6" 3' - 0" 2' - 0" 1' - 0" 1' - 3" 1' - 9" 3' - 0" 2' - 6" 4' - 0" 2' - 0" 1' - 0" 1' - 3" 2' - 6" 1' - 6" 1' - 0" 2' - 6" Casework Schedule 2' - 10 1/2" 2' - 0" 2' - 10 1/2" 2' - 0" 2' - 10 1/2" 2' - 0" 2' - 0" 3' - 0" 2' - 0" 1' - 0" 2' - 10 1/2" 2' - 0" 2' - 10 1/2" 2' - 0" 2' - 10 1/2" 2' - 0" 2' - 10 1/2" 2' - 0" 2' - 10 1/2" 2' - 0" 2' - 0" 2' - 6" 3' - 0" 0' - 0 3/4" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 1' - 9" 1' - 9" 1' - 9" 3' - 0" 3' - 0" 3' - 0" 2' - 0" 1' - 9" 1' - 9" 4 2 1 1 4 1 2 1 1 3 1 1 7 4 1 3 3 3 1 1 1 1 2' - 0" 3' - 6" 1' - 0" 4 Shelves 4 Shelves NOTE: ADU Cabinetry To-Be-Designed Roof Schedule Type Area 592 SF 424 SF A Generic - 6" Generic - 6" Metal Standing Seam - 6" 52 SF Metal Standing Seam - 6" 482 SF Metal Standing Seam - 6" 173 SF A: 5 B Generic - 6" Generic - 6" B: 2 650 SF 677 SF 1327 SF 1724 SF 4344.00 2358.00 1199.00 2613.00 4776.00 680.00 1534.00 918.00 1433.00 3258.00 2678.00 1946.00 15526.00 10452.00 979.00 3198.00 2841.00 2577.00 1065.00 2218.00 979.00 947.00 68519.00 84 SF 84 SF 55 SF 111 SF 40 SF 182 SF 222 SF 129 SF 136 SF 13 SF 214 SF 261 SF 50 SF 4 SF 364 SF 243 SF 436 SF 36 SF 85 SF 16 SF 36 SF Not Placed 48 SF 55 SF 26 SF 43 SF 66 SF 2871 SF 46 SF 176 SF Not Placed 35 SF 300 SF 37 SF 245 SF 839 SF 7' - 1 7/8" FINISH SCHEDULE Gyp. and Tile Gyp. and Tile Gyp. and Tile Gypsum Gypsum Gypsum Gypsum Gypsum Gypsum Gypsum Gypsum Gypsum Tile Tile Tile Concrete, Polished Wood Flooring Wood Flooring Wood Flooring Concrete, Polished Concrete, Polished Concrete, Polished Wood Flooring Concrete, Polished Concrete, Polished Concrete, Polished Wood Flooring Concrete, Polished Concrete, Polished Tile Tile Office : 1 Bathroom 1 Bathroom 2 Bathroom 3 Bedroom 1 Bedroom 2 Bedroom 3 Bedroom 4 Closet Entry Kitchen Laundry Linen Living Room Living Room Loft Powder Screened Porch WC Wetroom Wetroom Wetroom 3 WIC WIC WIC WIC A: 25 Bathroom Bedroom Closet Closet Kitchen Laundry Living Room B: 7 Rectangular Tub Faucet - Moen Align Faucet Vanity - Moen Align Sink - Undermount, Continental, Trench Sink Kitchen-Undermount Sharp Toilet-Domestic-3D Rectangular Tub Faucet Vanity - Moen Align Sink - Undermount, Continental, Trench Sink Kitchen-Undermount Sharp Toilet-Domestic-3D TB1 : 9 A F1 F3 S2 S3 T1 TB1 A: 24 B F3 S2 S3 T1 B: 5 Grand total: 38 8 1 9 3 1 7 7 1 4 1 24 1 1 1 2 5 38 ID MATERIAL NOTES AREA Length MARK MATERIAL FINISH AREA MODEL MANUFAC TURER URL WALL MATERIAL TAKEOFF FLOOR MATERIAL TAKEOFF Common brick soldier coursed 7' - 10" Smooth 44' - 6 3/4" Brick, Soldier Course Concrete - Cast-in-Place Concrete Common brick soldier coursed Brick, Soldier Course Stone-ADU Concrete - Cast-in-Place Concrete Tile-Backsplash-1-Bathroom 1 B1 B2 CONC 3 GYP Gypsum Wall Board STC2 Stucco-White TB1 : 22 A B1 CONC 3 GYP Gypsum Wall Board STC1 Stucco-Grey STC2 Stucco-White TB3 TW1 A: 114 B Stone-ADU B2 GYP Gypsum Wall Board STC2 Stucco-White B: 33 Tile-Backsplash-3-Bathroom 3 Tile-Wall-9- Short Stacked Green Smooth Smooth 47 SF 109 SF 333 SF 1501 SF 497 SF 20 SF 2507 SF 1239 SF 500 SF 8516 SF 1229 SF 2450 SF 85 SF 27 SF 14045 SF 706 SF 2879 SF 1083 SF 4669 SF Concrete, Polished Concrete, Lightweight Concrete - Cast-in-Place Concrete Deck Planks A CONC1 CONC2 CONC3 DECK RT DECK Rooftop Deck TF1 TF2 WC WF1 B TF1 WC WF1 Tile-Floor-1 Westcoat Oak Flooring Tile-Floor-1 TIle-Floor-2-Bedroom 1 Westcoat Oak Flooring Polished Lightweight concrete Exterior finish Interior finish Interior finish Interior finish Exterior finish Semi-Gloss Interior finish Exterior finish Semi-Gloss 1622 SF 148 SF 1622 SF 564 SF 204 SF 149 SF 36 SF 127 SF 1172 SF 106 SF 307 SF 964 SF MARK NAME COUNT MANUFACTURER MODEL PLUMBING FIXTURE SCHEDULE 916 Springdale Rd. Building #5, Suite 101 Austin, TX 78702 512.374.0946 T 512.374.0736 F www.krdb.com DEVELOPER ARCHITECT CHRIS KRAGER KRDB 916 SPRINGDALE RD. BLDG. 5, STE 101, AUSTIN, TX 78702 512.374.0946 CHRIS@KRDB.COM STRUCTURAL CIVIL MEP LANDSCAPING D O O W N E K E V A D O O W N E K 9 0 9 1 4 0 7 8 7 X T , I N T S U A STATUS: CD ISSUE DATE BP Submital 03/16/2022 REVISION SCHEDULE ID NAME DATE FINISHES A-603 5/6/2022 1:12:32 PM