Historic Landmark CommissionFeb. 14, 2022

6 - 1502 W 9th St - Updated Drawings — original pdf

Backup
Thumbnail of the first page of the PDF
Page 1 of 6 pages

SITE PLAN NOTES 2. 3. 5. 7. 8. 1. REFER TO G1.0 FOR CODE COMPLIANCE. REFER TO G2.0 FOR ADDITIONAL GENERAL NOTES. SITE INFORMATION SHOWN IS BASED FROM SURVEY DATED JUNE 17, 2020 PREPARED BY WATERLOO SURVEYORS. 4. CONTRACTOR SHALL FIELD VERIFY JOB CONDITIONS AND IMMEDIATELY NOTIFY ARCHITECT OF ANY DISCREPANCIES FROM CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY IF ANY DEFECTS IN THE EXISTING CONSTRUCTION ARE UNCOVERED DURING DEMOLITION WORK SO NECESSARY REPAIRS CAN BE MADE. REPORT ANY CONDITIONS THAT MAY DICTATE UNFORESEEN CHANGES IN THE WORK TO BE PROVIDED. 6. DEMOLITION SITE PLAN IS FOR GUIDANCE ONLY. ANY ADDITIONAL DEMOLITION WORK REQUIRED TO FULLY COMPLETE WORK, BUT NOT OTHERWISE SHOWN OR DESCRIBED IN THE DEMOLITION DRAWINGS SHALL BE CONSIDERED PART OF THE CONTRACT. THE INFORMATION SHOWN ON THESE DRAWINGS INDICATING SIZE, TYPE AND LOCATION OF ANY UNDERGROUND, SURFACE AND AERIAL UTILITIES OR OTHER EXISTING FEATURES IS NOT GUARANTEED TO BE EXACT OF COMPLETE. THE CONTRACTOR SHALL CONTACT THE AUSTIN AREA "ONE CALL" SYSTEM (1-800-344-8377) FOR EXISTING UTILITY LOCATIONS AT LEAST 48 HOURS PRIOR TO BEGINNING ANY EXCAVATION. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR FIELD VERIFYING LOCATIONS AND ELEVATIONS OF ALL EXISTING UTILITIES AFFECTED BY THIS PROJECT'S CONSTRUCTION, IN ORDER TO AVOID DAMAGING THOSE UTILITIES, AND SHALL IMMEDIATELY ARRANGE FOR REPAIR AND RESTORATION OF CONTRACTOR-DAMAGED UTILITIES, TO THE SATISFACTION OF THE UTILITY COMPANY, AT THE EXPENSE OF THE CONTRACTOR. 9. WHERE A SEAMLESS PATCH BETWEEN EXISTING AND NEW SURFACES AND/OR ITEMS IS NOT POSSIBLE OR PRACTICAL, REMOVE EXISTING SURFACE AND/OR ITEM BACK TO NEAREST JOINT AND REPLACE WITH NEW TO MATCH. 10. ALL HAULING AND DISPOSAL OF DEMOLISHED ITEMS SHALL BE PROVIDED BY CONTRACTOR. TREE LIST 0 0 . 4 1 1 0 0 . 3 1 1 ) ' 0 0 . 0 6 E " 0 0 0 0 ° 0 6 ' S ( ' 5 0 . 0 6 W ' " 3 1 4 1 ° 0 6 S Y E L L A ) W O R T F 0 1 ( 0 0 . 4 1 1 LEGEND AND SCALE // // // // // EXISTING FENCE LINE OH EXISTING OVERHEAD LINE EXISTING PUBLIC UTILITY EASEMENT EXISTING TOPOGRAPHY LINE EXISTING ELEMENT TO BE REMOVED PROPERTY LINE SET BACK LINE ADJACENT PROPERTY LINE 8' 4' 0' 10' 20' FULL SIZE SCALE : 1" = 10'-0" OR 1:120 (HALF SIZE SCALE: 1" = 20'-0" OR 1:240) TRUE NORTH WEISS ARCHITECTURE 3 3 5 5 B E E C A V E R D S T U D I O # 3 0 3 A U S T I N T X 7 8 7 4 6 ( 5 1 2 ) 4 4 7 - 6 8 0 6 T E L W E I S S A R C . C O M PRELIMINARY REVIEW SET NOT FOR PERMITTING REGULATORY APPROVAL OR CONSTRUCTION 14 FEB 2022 N O I T I D D A T E E R T S H T 9 3 0 7 8 7 S A X E T , N I T S U A , T E E R T S H T 9 . W 2 0 5 1 form, This document, whether in hard copy or digital is copyrighted and an instrument of services in respect to the project for which it was proposed. This document is not intended or authorized for use by any party on any other project. Any reuse including copying and/or modifying this document, without written permission from Weiss for Architecture, specific is a violation of purpose Federal Copyright law. inc. intended the N O I I T P R C S E D E T A D T E S G N W A R D I X X / X X / X X # . V E -R JOB NO. DRAWN BY R2203 LL SHEET NAME DEMO SITE PLAN SHEET NUMBER DS1.1 O H OH OH O H OH OH O H O H OH OH 620 OH 619 101.00 N 29°59'10" E N 30°00'00" E OH OH OH OH WV O H WM 99.00 1 0 4.0 0 105.00 626 106.00 627 107.00 LOT 9 219.75' (ACTUAL TYP.) 220.00' (RECORD TYP.) 0 2.0 1 1 0 0 . 8 0 1 0 0 . 0 1 1 LOT 10 13,106.94 SF 0 0 . 1 1 1 112.00 624 0 0 . 1 1 1 0 2 . 0 1 1 0 0 . 2 0 1 618 S 30°00'00" W S 30°00'00" W 1 0 6 . 0 0 1 0 8 . 0 0 0 7 . 0 0 1 621 1 0 9 . 0 0 1 1 0 . 0 0 111.00 622 LOT 11 113.00 623 220.00' 220.48' OH OH EM OH 0 0 . 3 0 1 T1 OH GM 104.00 1 0 5.0 0 102.00 103.00 c o ) ' 0 0 . 0 6 W ' " 0 0 0 0 ° 0 6 N ( ' 0 0 . 0 6 W ' " 6 1 2 3 ° 9 5 N 0 0 . 0 0 1 0 0 . 1 . 0 1 T E E R T S H T 9 . W 2 0 5 1 ) W O R T F 0 6 ( O H O H O H O H O H O H O H O H O H O H O H O H O H O H 0 0 . 0 0 1 0 0 . 0 0 1 SCALE:1 DEMO SITE PLAN 1" - 10'-0" OR 1:120 EXISTING BEDROOM XXX EXISTING CLOSET XXX EXISTING LIVING ROOM XXX EXISTING PATIO XXX EXISTING SCREENED PORCH XXX SCALE:1 LEVEL 1 - DEMOLITION PLAN 3/16" = 1'-0" REFER TO SHEET AS1.0 FOR VISITABILITY REQUIREMENTS. WEISS ARCHITECTURE SHEET NOTES 1. REFER TO SHEET G1.0 FOR CODE COMPLIANCE. REFER TO SHEET G2.0 FOR GENERAL NOTES. 2. 3. 4. REFER TO A3.0 SERIES FOR EXTERIOR ELEVATIONS AND ADDITIONAL WINDOW TAGS. 5. DO NOT SCALE DRAWINGS. 6. VERIFY ALL DIMENSIONS IN FIELD AND REPORT ALL DISCREPANCIES TO THE ARCHITECT FOR RESOLUTION PRIOR TO COMMENCEMENT OF WORK. 7. ALL DIMENSIONS TO FACE OF STUD, FACE OF CONCRETE, CENTERLINE OF STRUCTURE, CENTER OF OPENING OR FIXTURE, UNLESS NOTED OTHERWISE. 8. ALL DOOR FRAMES SHALL BE LOCATED 4" FROM NEAREST PERPENDICULAR WALL OR CENTER ON WALL SEGMENT AS ILLUSTRATED, UNLESS DIMENSIONED OTHERWISE. 9. WALL FRAMING SHALL BE AS NOTED BELOW UNLESS NOTED OTHERWISE BY STRUCTURAL ENGINEER. CONSULT ARCHITECT ON ANY DISCREPANCIES. A. ALL EXTERIOR & LOADING BEARING WALLS SHALL BE CONSTRUCTED WITH 2X6 OR 2X4 WOOD FRAMING AT 18" ON CENTER, U.N.O. REFER TO WALL LEGEND BELOW. B. ALL SIMPLE (NON-LOAD BEARING) INTERIOR PARTITIONS SHALL BE CONSTRUCTED WITH 2X4 WOOD FRAMING AT 24" ON CENTER, U.N.O. C. ALL INTERIOR AND EXTERIOR PLUMBING WALLS TO BE CONSTRUCTED WITH 2X6 FRAMING, U.N.O. D. ALL INTERIOR PARTITIONS SUPPORTING POCKET DOORS TO BE CONSTRUCTED WITH 2X6 FRAMING, U.N.O. 10. ROOF AND FLOOR FRAMING SHALL BE PER STRUCTURAL DRAWINGS. TRUSS MANUFACTURER SHALL SUPPLY SHOP DRAWINGS SEALED BY AN ENGINEER TO DESIGN TEAM AND CONTRACTOR FOR APPROVAL PRIOR TO FABRICATION. 10. EXTERIOR WALL INSULATION - ALL EXTERIOR WALLS SHALL RECEIVE MIN. R-19 CELLULOSE BLOWN-IN INSULATION WITH OPTIONAL SPRAY FOAM LAYER ADJACENT TO EXTERIOR WALL. 11. ROOF INSULATION - ALL ROOF SHALL RECEIVE MIN. R-36 OPEN CELL SPRAY FOAM INSULATION. 12. FLOOR INSULATION - ALL SPACES BETWEEN FLOORS SHALL RECEIVE MIN. R-30 BATT INSULATION BETWEEN FLOORS. 13. INTERIOR WALL INSULATION - ALL BEDROOMS, BATHROOM AND LAUNDRY ROOM WALLS SHALL RECEIVE SOUND BATT INSULATION. 14. CONTRACTOR SHALL PROVIDE BLOCKING IN WALLS AND CEILINGS AS REQUIRED FOR ALL ACCESSORIES, WALL MOUNTED ITEMS, CEILING FANS, ETC. 15. USE 1 2" WATER RESISTANT GYP BD IN BATHROOM AND KITCHEN ON ALL WALLS EXCEPT BEHIND CERAMIC TILE AND BATH TUB WHERE TILE BACKER BOARD (DENSHIELD) IS USED. 16. ALL DIMENSIONS ARE TAKEN FROM EDGE OF SLAB TO FACE OF WOOD, UNLESS NOTED "CLEAR". 17. ALL DOOR OPENINGS TO BE 4" FROM ADJACENT WALL, U.N.O. 18. CONTRACTOR TO INSTALL BLOCKING IN WALLS AND CEILINGS AS REQUIRED FOR ALL ACCESSORIES, WALL MOUNTED ITEMS, CEILING FANS, ETC. 19. TRUSS MANUFACTURER SHALL SUPPLY SHOP DRAWINGS SEALED BY AN ENGINEER TO ARCHITECT AND CONTRACTOR FOR APPROVAL PRIOR TO FABRICATION. 20. CONTACT ARCHITECT/OWNER WITH ANY FRAMING QUESTIONS/DISCREPANCIES. LEGEND AND SCALE EXISTING WALL/ELEMENT TO REMAIN REMOVE EXISTING WALL REMOVE EXISTING ELEMENT 2' 0' 4' 8' FULL SIZE SCALE : 1/4" = 1'-0" (HALF SIZE SCALE: 1 8" = 1'-0") NORTH 3 3 5 5 B E E C A V E R D S T U D I O # 3 0 3 A U S T I N T X 7 8 7 4 6 ( 5 1 2 ) 4 4 7 - 6 8 0 6 T E L W E I S S A R C . C O M PRELIMINARY REVIEW SET NOT FOR PERMITTING REGULATORY APPROVAL OR CONSTRUCTION 14 FEB 2022 N O I T I D D A T E E R T S H T 9 3 0 7 8 7 S A X E T , N I T S U A , T E E R T S H T 9 . W 2 0 5 1 form, This document, whether in hard copy or digital is copyrighted and an instrument of services in respect to the project for which it was proposed. This document is not intended or authorized for use by any party on any other project. Any reuse including copying and/or modifying this document, without written permission from Weiss for Architecture, specific is a violation of purpose Federal Copyright law. inc. intended the N O I I T P R C S E D E T A D T E S G N W A R D I X X / X X / X X # . V E -R JOB NO. DRAWN BY R2203 LL SHEET NAME LEVEL 1 DEMOLITION FLOOR PLAN SHEET NUMBER D1.1 CLOSET 1 XXX 4'0" X'0" FX 3'0" 8'0" PK 2'8" 8'0" SW (2) 3'0" 8'0" BP CLOSET 2 XXX HALL XXX CLG HGT 9' - 0" P U 4'0" X'0" FX UP EXISTING 108' 8" F.F. MASTER BEDROOM XXX CLG HGT 11' - 0" ADDITION 111' 8" F.F. N E N L I TOILET XXX 2'8" 8'0" PK BENCH 2'0" 7'0" GLZ MASTER BATHROOM XXX CLG HGT 11' - 0" 2'8" 8'0" SW (4) 3'0" 10'0" SL DECK 111' 6-1/2" F.F. UP EXISTING 108' 5" F.F. 1/A3.1 . 1 3 A / 2 SCALE:1 FLOOR PLAN : MASTER BEDROOM ADDITION 1/4" = 1'-0" REFER TO SHEET AS1.0 FOR VISITABILITY REQUIREMENTS. WEISS ARCHITECTURE SHEET NOTES 1. REFER TO SHEET G1.0 FOR CODE COMPLIANCE. REFER TO SHEET G2.0 FOR GENERAL NOTES. 2. 3. 4. REFER TO A3.0 SERIES FOR EXTERIOR ELEVATIONS AND ADDITIONAL WINDOW TAGS. 5. DO NOT SCALE DRAWINGS. 6. VERIFY ALL DIMENSIONS IN FIELD AND REPORT ALL DISCREPANCIES TO THE ARCHITECT FOR RESOLUTION PRIOR TO COMMENCEMENT OF WORK. 7. ALL DIMENSIONS TO FACE OF STUD, FACE OF CONCRETE, CENTERLINE OF STRUCTURE, CENTER OF OPENING OR FIXTURE, UNLESS NOTED OTHERWISE. 8. ALL DOOR FRAMES SHALL BE LOCATED 4" FROM NEAREST PERPENDICULAR WALL OR CENTER ON WALL SEGMENT AS ILLUSTRATED, UNLESS DIMENSIONED OTHERWISE. 9. WALL FRAMING SHALL BE AS NOTED BELOW UNLESS NOTED OTHERWISE BY STRUCTURAL ENGINEER. CONSULT ARCHITECT ON ANY DISCREPANCIES. A. ALL EXTERIOR & LOADING BEARING WALLS SHALL BE CONSTRUCTED WITH 2X6 OR 2X4 WOOD FRAMING AT 18" ON CENTER, U.N.O. REFER TO WALL LEGEND BELOW. B. ALL SIMPLE (NON-LOAD BEARING) INTERIOR PARTITIONS SHALL BE CONSTRUCTED WITH 2X4 WOOD FRAMING AT 24" ON CENTER, U.N.O. C. ALL INTERIOR AND EXTERIOR PLUMBING WALLS TO BE CONSTRUCTED WITH 2X6 FRAMING, U.N.O. D. ALL INTERIOR PARTITIONS SUPPORTING POCKET DOORS TO BE CONSTRUCTED WITH 2X6 FRAMING, U.N.O. 10. ROOF AND FLOOR FRAMING SHALL BE PER STRUCTURAL DRAWINGS. TRUSS MANUFACTURER SHALL SUPPLY SHOP DRAWINGS SEALED BY AN ENGINEER TO DESIGN TEAM AND CONTRACTOR FOR APPROVAL PRIOR TO FABRICATION. 10. EXTERIOR WALL INSULATION - ALL EXTERIOR WALLS SHALL RECEIVE MIN. R-19 CELLULOSE BLOWN-IN INSULATION WITH OPTIONAL SPRAY FOAM LAYER ADJACENT TO EXTERIOR WALL. 11. ROOF INSULATION - ALL ROOF SHALL RECEIVE MIN. R-36 OPEN CELL SPRAY FOAM INSULATION. 12. FLOOR INSULATION - ALL SPACES BETWEEN FLOORS SHALL RECEIVE MIN. R-30 BATT INSULATION BETWEEN FLOORS. 13. INTERIOR WALL INSULATION - ALL BEDROOMS, BATHROOM AND LAUNDRY ROOM WALLS SHALL RECEIVE SOUND BATT INSULATION. 14. CONTRACTOR SHALL PROVIDE BLOCKING IN WALLS AND CEILINGS AS REQUIRED FOR ALL ACCESSORIES, WALL MOUNTED ITEMS, CEILING FANS, ETC. 15. USE 1 2" WATER RESISTANT GYP BD IN BATHROOM AND KITCHEN ON ALL WALLS EXCEPT BEHIND CERAMIC TILE AND BATH TUB WHERE TILE BACKER BOARD (DENSHIELD) IS USED. 16. ALL DIMENSIONS ARE TAKEN FROM EDGE OF SLAB TO FACE OF WOOD, UNLESS NOTED "CLEAR". 17. ALL DOOR OPENINGS TO BE 4" FROM ADJACENT WALL, U.N.O. 18. CONTRACTOR TO INSTALL BLOCKING IN WALLS AND CEILINGS AS REQUIRED FOR ALL ACCESSORIES, WALL MOUNTED ITEMS, CEILING FANS, ETC. 19. TRUSS MANUFACTURER SHALL SUPPLY SHOP DRAWINGS SEALED BY AN ENGINEER TO ARCHITECT AND CONTRACTOR FOR APPROVAL PRIOR TO FABRICATION. 20. CONTACT ARCHITECT/OWNER WITH ANY FRAMING QUESTIONS/DISCREPANCIES. LEGEND AND SCALE EXTERIOR 2X4 WALL WITH BRICK EXTERIOR 2X4 WALL WITH HARDIE SIDING EXTERIOR 2X6 WALL WITH HARDIE SIDING INTERIOR 2X4 WALL INTERIOR 2X6 WALL 2X4 PARTIAL HEIGHT WALL 2X6 WALL BELOW INTERIOR 2X4 FLAT STUD WALL 2' 0' 4' 8' FULL SIZE SCALE : 1/4" = 1'-0" (HALF SIZE SCALE: 1 8" = 1'-0") NORTH 3 3 5 5 B E E C A V E R D S T U D I O # 3 0 3 A U S T I N T X 7 8 7 4 6 ( 5 1 2 ) 4 4 7 - 6 8 0 6 T E L W E I S S A R C . C O M PRELIMINARY REVIEW SET NOT FOR PERMITTING REGULATORY APPROVAL OR CONSTRUCTION 14 FEB 2022 N O I T I D D A T E E R T S H T 9 3 0 7 8 7 S A X E T , N I T S U A , T E E R T S H T 9 . W 2 0 5 1 form, This document, whether in hard copy or digital is copyrighted and an instrument of services in respect to the project for which it was proposed. This document is not intended or authorized for use by any party on any other project. Any reuse including copying and/or modifying this document, without written permission from Weiss for Architecture, specific is a violation of purpose Federal Copyright law. inc. intended the N O I I T P R C S E D E T A D T E S G N W A R D I X X / X X / X X # . V E -R JOB NO. DRAWN BY R2203 LL SHEET NAME FIRST FLOOR PLAN SHEET NUMBER A1.1 ROOF TERRACE XXX SHEET NOTES 1. 2. 4. 5. 6. 7. 9. PROVIDE GUTTERS AND DOWNSPOUTS. BASIS OF DESIGN IS STANDING SEAM METAL ROOF. TPO OVER GARAGE. 3. VENT FOR ALL MECH/PLUMBING FIXTURES. FIELD VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. PROVIDE R-30 INSULATION BETWEEN ROOF AND CEILING. PROVIDE RADIANT BARRIER ROOF DECKING. FLASHING, UNDERLAYMENT, AND FASTENING DETAILS PER ROOF MANUF. INSTALLER. VERIFY WITH ARCHITECT. 8. COMPLETELY SEAL ROOF. PROVIDE FRESH AIR INTAKES AS PART OF HVAC SYSTEM. SPRAY-FOAM INSULATION AT TRUSS AND SECOND FLOOR CEILING. SHEET ROCK BARRIER AROUND ALL MECHANICAL UNITS. 10. PROVIDE DECKING FOR MECHANICAL EQUIPMENT AND STORAGE. WEISS ARCHITECTURE 3 3 5 5 B E E C A V E R D S T U D I O # 3 0 3 A U S T I N T X 7 8 7 4 6 ( 5 1 2 ) 4 4 7 - 6 8 0 6 T E L W E I S S A R C . C O M PRELIMINARY REVIEW SET NOT FOR PERMITTING REGULATORY APPROVAL OR CONSTRUCTION 14 FEB 2022 N O I T I D D A T E E R T S H T 9 3 0 7 8 7 S A X E T , N I T S U A , T E E R T S H T 9 . W 2 0 5 1 form, This document, whether in hard copy or digital is copyrighted and an instrument of services in respect to the project for which it was proposed. This document is not intended or authorized for use by any party on any other project. Any reuse including copying and/or modifying this document, without written permission from Weiss for Architecture, specific is a violation of purpose Federal Copyright law. inc. intended the N O I I T P R C S E D E T A D T E S G N W A R D I X X / X X / X X # . V E -R JOB NO. DRAWN BY R2203 LL SHEET NAME ROOF PLAN SHEET NUMBER A1.3 SCALE:1 ROOF PLAN 1/4" = 1'-0" SCALE 2' 0' 4' 8' FULL SIZE SCALE : 1/4" = 1'-0" (HALF SIZE SCALE: 1 8" = 1'-0") NORTH SHEET NOTES 1. REFER TO G1.0 FOR CODE COMPLIANCE. REFER TO G2.0 FOR GENERAL NOTES. REFER TO XXX FOR EXTERIOR ASSEMBLY NOTES AND SPECIFICATIONS. REFER TO XXX FOR DOOR AND WINDOW TYPES & SCHEDULE 2. 3. 4. 3. CONTRACTOR SHALL PROVIDE GUTTER AND DOWNSPOUT SYSTEM TO POSITIVELY DRAIN ROOF AWAY FROM BUILDING AND INTO LANDSCAPE BEDS. 4. ALL WINDOW HEADER HEIGHTS ON LOWER AND UPPER FLOOR SHALL BE 7'-8"' AFF UNO. 5. ALL WINDOWS LOCATED WITHIN 24" OF AN EXTERIOR OR INTERIOR DOOR SHALL RECEIVE TEMPERED SAFETY GLASS PER IRC 2015. WINDOW MANUFACTURER AND CONTRACTOR SHALL VERIFY ALL TEMPERED GLASS LOCATIONS PER APPLICABLE CODES. 6. WINDOW MANUFACTURER AND CONTRACTOR SHALL VERIFY ALL EGRESS WINDOWS ARE INSTALLED PER APPLICABLE CODE REQUIREMENTS. 7. ALL WINDOWS SHALL HAVE U-FACTOR 0.40 OR LESS PER CITY OF AUSTIN CODE AMENDMENT. 8. ALL WINDOWS SHALL BE ALUMINUM CLAD AND FACTORY MULLED WHEN POSSIBLE. 9. PROVIDE MIN. 4" TRIM AT ALL SIDES OF ALUMINUM WINDOWS. 10. EXPOSED FOUNDATION SHALL BE MIN. 8" AND A MAXIMUM OF x INCHES ABOVE GRADE. UNDERPIN ALL EXPOSED FOUNDATIONS. 11. GRADE LINES SHOWN ON ELEVATION DRAWINGS SHALL NOT BE CONSTRUED TO REPRESENT ACTUAL FINISH GRADES. VERIFY FINISH GRADE ON JOB SITE AND NOTIFY ARCHITECT OF ANY SIGNIFICANT DISCREPANCIES PRIOR TO STARTING WORK. 12. ACTUAL ELEVATIONS TO VARY PER GRADE OF EXISTING 13. ALL PLUMBING, APPLIANCE, AND GAS VENTS TO BE GANGED TO THE LEAST POSSIBLE NUMBER OF ROOF PENETRATIONS AND KEPT TO REAR OF ROOF WHENEVER POSSIBLE. 14. CONTRACTOR SHALL INSTALL ALL PRODUCTS AND ASSEMBLIES PER MANUFACTURER'S RECOMMENDED INSTALLATION. 15. ALL EXTERIOR SYSTEMS SHALL BE INSTALLED TO ASSURE ADEQUATE DRAINAGE IS PROVIDED. 16. TEMP GLZ = PROVIDE TEMPERED SAFETY GLASS AT ALL REQUIRED LOCATIONS AS REQUIRED BY CODE. ADDITION TERRACE: FINISH FLOOR 113' 0" ADDITION: PLATE HEIGHT 111' 0" ADDITION: FINISH FLOOR 103' 0" EXISTING LVL 1 : FINISH FLOOR 100' 0" LOT. ADDITION TERRACE: FINISH FLOOR 113' 0" ADDITION: PLATE HEIGHT 111' 0" ADDITION: FINISH FLOOR 103' 0" EXISTING LVL 1 : FINISH FLOOR 100' 0" LEGEND AND SCALE 2' 0' 4' 8' FULL SIZE SCALE : 1/4" = 1'-0" (HALF SIZE SCALE: 1 8" = 1'-0") WEISS ARCHITECTURE 3 3 5 5 B E E C A V E R D S T U D I O # 3 0 3 A U S T I N T X 7 8 7 4 6 ( 5 1 2 ) 4 4 7 - 6 8 0 6 T E L W E I S S A R C . C O M PRELIMINARY REVIEW SET NOT FOR PERMITTING REGULATORY APPROVAL OR CONSTRUCTION 14 FEB 2022 N O I T I D D A T E E R T S H T 9 3 0 7 8 7 S A X E T , N I T S U A , T E E R T S H T 9 . W 2 0 5 1 This document, whether in hard copy or digital form, is copyrighted and an instrument of services in respect to the project for which it was proposed. This document is not intended or authorized for use by any party on any other project. Any reuse including copying and/or modifying this document, without written permission from Weiss for Architecture, specific is a violation of purpose Federal Copyright law. inc. intended the N O I I T P R C S E D E T A D T E S G N W A R D I X X / X X / X X # . V E -R JOB NO. DRAWN BY R2203 LL SHEET NAME EXTERIOR ELEVATIONS SHEET NUMBER A3.1 SCALE:1 EAST EXTERIOR ELEVATION 1/4" = 1'-0" SCALE:2 NORTH EXTERIOR ELEVATION 1/4" = 1'-0" SCALE:1 SOUTH EXTERIOR ELEVATION 1/4" = 1'-0" SHEET NOTES 1. REFER TO G1.0 FOR CODE COMPLIANCE. REFER TO G2.0 FOR GENERAL NOTES. REFER TO XXX FOR EXTERIOR ASSEMBLY NOTES AND SPECIFICATIONS. REFER TO XXX FOR DOOR AND WINDOW TYPES & SCHEDULE 2. 3. 4. 3. CONTRACTOR SHALL PROVIDE GUTTER AND DOWNSPOUT SYSTEM TO POSITIVELY DRAIN ROOF AWAY FROM BUILDING AND INTO LANDSCAPE BEDS. 4. ALL WINDOW HEADER HEIGHTS ON LOWER AND UPPER FLOOR SHALL BE 7'-8"' AFF UNO. 5. ALL WINDOWS LOCATED WITHIN 24" OF AN EXTERIOR OR INTERIOR DOOR SHALL RECEIVE TEMPERED SAFETY GLASS PER IRC 2015. WINDOW MANUFACTURER AND CONTRACTOR SHALL VERIFY ALL TEMPERED GLASS LOCATIONS PER APPLICABLE CODES. 6. WINDOW MANUFACTURER AND CONTRACTOR SHALL VERIFY ALL EGRESS WINDOWS ARE INSTALLED PER APPLICABLE CODE REQUIREMENTS. 7. ALL WINDOWS SHALL HAVE U-FACTOR 0.40 OR LESS PER CITY OF AUSTIN CODE AMENDMENT. 8. ALL WINDOWS SHALL BE ALUMINUM CLAD AND FACTORY MULLED WHEN POSSIBLE. 9. PROVIDE MIN. 4" TRIM AT ALL SIDES OF ALUMINUM WINDOWS. 10. EXPOSED FOUNDATION SHALL BE MIN. 8" AND A MAXIMUM OF x INCHES ABOVE GRADE. UNDERPIN ALL EXPOSED FOUNDATIONS. 11. GRADE LINES SHOWN ON ELEVATION DRAWINGS SHALL NOT BE CONSTRUED TO REPRESENT ACTUAL FINISH GRADES. VERIFY FINISH GRADE ON JOB SITE AND NOTIFY ARCHITECT OF ANY SIGNIFICANT DISCREPANCIES PRIOR TO STARTING WORK. 12. ACTUAL ELEVATIONS TO VARY PER GRADE OF EXISTING LOT. 13. ALL PLUMBING, APPLIANCE, AND GAS VENTS TO BE GANGED TO THE LEAST POSSIBLE NUMBER OF ROOF PENETRATIONS AND KEPT TO REAR OF ROOF WHENEVER POSSIBLE. 14. CONTRACTOR SHALL INSTALL ALL PRODUCTS AND ASSEMBLIES PER MANUFACTURER'S RECOMMENDED INSTALLATION. 15. ALL EXTERIOR SYSTEMS SHALL BE INSTALLED TO ASSURE ADEQUATE DRAINAGE IS PROVIDED. 16. TEMP GLZ = PROVIDE TEMPERED SAFETY GLASS AT ALL REQUIRED LOCATIONS AS REQUIRED BY CODE. LEGEND AND SCALE 2' 0' 4' 8' FULL SIZE SCALE : 1/4" = 1'-0" (HALF SIZE SCALE: 1 8" = 1'-0") WEISS ARCHITECTURE 3 3 5 5 B E E C A V E R D S T U D I O # 3 0 3 A U S T I N T X 7 8 7 4 6 ( 5 1 2 ) 4 4 7 - 6 8 0 6 T E L W E I S S A R C . C O M PRELIMINARY REVIEW SET NOT FOR PERMITTING REGULATORY APPROVAL OR CONSTRUCTION 14 FEB 2022 N O I T I D D A T E E R T S H T 9 3 0 7 8 7 S A X E T , N I T S U A , T E E R T S H T 9 . W 2 0 5 1 form, This document, whether in hard copy or digital is copyrighted and an instrument of services in respect to the project for which it was proposed. This document is not intended or authorized for use by any party on any other project. Any reuse including copying and/or modifying this document, without written permission from Weiss for Architecture, specific is a violation of purpose Federal Copyright law. inc. intended the N O I I T P R C S E D E T A D T E S G N W A R D I X X / X X / X X # . V E -R JOB NO. DRAWN BY R2203 LL SHEET NAME EXTERIOR ELEVATIONS SHEET NUMBER A3.2