2 - 1304 Bob Harrison - Plans — original pdf
Backup
Residential New Construction and Addition Permit Application Property Information Project Address: Legal Description: Zoning District: DevelopmentATX.com | Phone: 311 (or 512-974-2000 outside Austin) For submittal and fee information, see austintexas.gov/digitaldevelopment Download application before entering information. Tax Parcel ID: Lot Area (sq ft): Historic District (if applicable): Neighborhood Plan Area (if applicable): Required Reviews Is project participating in S.M.A.R.T. Housing? (If yes, attach signed certification letter from NHCD, and signed conditional approval letter from Austin Energy Green Building) Is this site within an Airport Overlay Zone? (If yes, approval through Aviation is required) Y Y N N Does project have a Green Building requirement? (If yes, attach signed conditional approval letter from Austin Energy Green Building) Y N Does this site have a septic system? Y N (If yes, submit a copy of approved septic permit. OSSF review required) Does the structure exceed 3,600 square feet total under roof? Is this property within 200 feet of a hazardous pipeline? Y Y N N (If yes, Fire review is required) (If yes, Fire review is required) Is this site located within an Erosion Hazard Zone? Is this property within 100 feet of the 100-year floodplain? Y N (If yes, EHZ review is required) Y N (Proximity to floodplain may require additional review time.) Are there trees 19” or greater in diameter on/adjacent to the property? If yes, how many?_____ ( Provide plans with a tree survey, tree review required.) Y N Was there a pre-development consultation for the Tree Review? Y N Proposed impacts to trees: (Check all that apply) Root zone Canopy Removal None/Uncertain Is this site in the Capital View Corridor? (If yes, a preliminary review through land use is needed to determine if full view corridor review is required.) Does this site currently have: water availability? wastewater availability? Y Y Y N N N Is this site within the Residential Design and Compatibility Standards Ordinance Boundary Area? (LDC 25-2 Subchapter F) Y N (If no, contact Austin Water Utility to apply for water/wastewater taps and/or service extension request.) (If yes, submit approved auxiliary and potable plumbing plans.) Does this site have or will it have an auxiliary water source? (Auxiliary water supplies are wells, rainwater harvesting, river water, lake water, reclaimed water, etc.) Does this site require a cut or fill in excess of four (4) feet? Y N Y N (If yes, contact the Development Assistance Center for a Site Plan Exemption) N Y Is this site within the Waterfront Overlay? (LDC 25-2 Subchapter C Article 3) Does this site front a paved street? (If no, contact Development Assistance Center for Site Plan requirements.) Does this site have a Board of Adjustment (BOA) variance? Y N (If yes, provide a copy of decision sheet. Note: A permit cannot be approved within 10 days of approval of a variance from BOA.) Description of Work Is Total New/Added Building Area > 5,000 sq. Ft.? Is this site within the Lake Austin Overlay? (LDC 25-2-180, 25-2-647) Is this site adjacent to a paved alley? (Public Works approval required to take access from a public alley.) Y N Y Y Y N N (If yes, construction material recycling is required per LDC 25-11-39) N Case # _________________________ (if applicable) Existing Use: vacant single-family residential duplex residential two-family residential other: _________ Proposed Use: vacant single-family residential duplex residential two-family residential Project Type: new construction addition addition/remodel other: _________ other:__________ Will all or part of an existing exterior wall, structure, or roof be removed as part of the project? (Notes: Removal of all or part of a structure requires a Demolition Permit Application per LDC 25-11-37. A demo permit is not required for the removal of all or part of an interior wall, floor or ceiling) # existing bedrooms: # bedrooms upon completion: # baths upon completion: # baths existing: N Y Project Description: (Note: Please provide thorough description of project. Attach additional pages as necessary.) _________________________________________________________________________________________________ _________________________________________________________________________________________________ Trade Permits Required (Check as applicable): plumbing mechanical (HVAC) concrete (R.O.W.) electric City of Austin | Residential New Construction and Addition Permit Application 11/17/20 | Page 1 of 7 Total Remodeled Floor Area (if applicable) sq ft. (work within existing habitable square footage) Job Valuation – For Properties in a Floodplain Only Total Job Valuation: $__________________ Note: The total job valuation should be the sum total of all valuations noted to the right. Labor and materials only, rounded to nearest dollar. Site Development Information Amount for Primary Structure: Y Elec: Y N | Plmbg: $ ________________ N N | Mech: Y $ ________________ Amount for Accessory Structure: Elec: Y N | Plmbg: Y N | Mech: Y N Area Description Note: Provide a separate calculation for each distinct area. Attach additional sheets as necessary. Measurements are to the outside surface of the exterior wall. Existing sq. ft. to Remain New/Added sq. ft. Total sq. ft. Bldg. 1 Bldg. 2 Bldg. 1 Bldg. 2 Bldg. 1 Bldg. 2 a) 1st Floor conditioned area b) 2nd Floor conditioned area c) 3rd Floor conditioned area d) Basement e) Covered parking (garage or carport) f) Covered patio, deck, porch, and/or balcony area(s) g) Other covered or roofed area h) Uncovered wood decks Total Building Area (total a through h) i) Pool j) Spa k) Remodeled Floor Area, excluding Addition / New Construction The Calculation Aid on page 7 is to be used to complete the following calculations and to provide additional information. Building Coverage Information Note: Building Coverage means the area of a lot covered by buildings or roofed areas, but excludes ground-level paving, landscaping, open recreational facilities, incidental projecting eaves, balconies, and similar features. Pools, ponds, and fountains are not included in this measurement. (LDC 25-1-21) Total Building Coverage (sq ft): ___________ % of lot size: ________ Impervious Cover Information Note: Impervious cover is the total horizontal area of covered spaces including building coverage, paved areas, walkways, and driveways. The term excludes pools, ponds, fountains, and areas with gravel placed over pervious surfaces that are used only for landscaping or by pedestrians. For an uncovered wood deck that has drainage spaces between the deck boards and that is located over a pervious surface, 50 percent of the horizontal area of the deck is included in the measurement of impervious cover. (LDC 25-1-23) Total Impervious Cover (sq ft): _____________ % of lot size: ________ Setbacks Are any existing structures on this site a non-compliant structure based on a yard setback requirement? (LDC 25-2-492) Does any structure (or an element of a structure) extend over or beyond a required yard? (LDC 25-2-513) Y Y Is front yard setback averaging being utilized on this property? (LDC 25-2, Subchapter F, Sec. 2.3 or 25-2-778) Height Information (LDC 25-1-21 or 25-2 Subchapter F, Section 3.4) Parking (LDC 25-6 Appendix A & 25-6-478) N N Y N Building Height: _______ ft ___ in Number of Floors: _____ # of spaces required: ________ # of spaces provided: ________ Right-of-Way Information Is a sidewalk required for the proposed construction? (LDC 25-6-353) *Sidewalks are to be installed on any new construction of a single family, two-family or duplex residential structure and any addition to an existing building that Y N increases the building’s gross floor area by 50 % or more. Will a Type I driveway approach be installed, relocated, removed or repaired as part of this project? Y N Width of approach (measured at property line): ___________ ft Distance from intersection (for corner lots only): __________ ft Are storm sewer inlets located within ten (10) feet of the end of any proposed driveway? (New driveways within ten(10) feet of an inlet will require additional review) Y N City of Austin | Residential New Construction and Addition Permit Application 11/17/20 | Page 2 of 7 1304 BOB HARRISON STREET, AUSTIN TEXAS, 78702 FRONT FACADE REAR FACADE WEST FACADE EAST FACADE EXISTING ADU EXISTING ADU N 79.59'52" E 46' 5' REAR SETBACK 23'-11" REMOVE DECK 32'-0" REMOVE EXISTING ADDITION " 9 9 . 9 2 1 " 0 0 . 0 3 1 ' E " 0 0 0 0 . 0 1 S K C A B T E S E D S I ' 5 SINGLE STORY HOME TO REMAIN AC REPLACE PORCH 25' FRONT SETBACK PAVERS TO REMAIN EXISTING 25" DIAMETER LIVE OAK TREE IN NEIGHBORS YARD. EXISTING FENCE BETWEEN PROPERTIES TO REMAIN. TREE IS 39' FROM PROPOSED SITE WORK REMOVE STORAGE SHED " 1 1 - ' 8 K C A B T E S E D S " 3 - ' 0 1 I ' 5 " 0 - ' 8 2 " 0 - ' 8 5'-4" W ' " 0 0 0 0 . 0 1 N N 79.59'52" E 46' 5' REAR SETBACK " 6 0'- 1 3 9'-1 0" MASTER SUITE ADDITION CONCRETE DECK DINING ADDITION K C A B T E S E D S I ' 5 NEW OVERFRAMED CRICKET K C A B T E S E D S I ' 5 " 9 9 . 9 2 1 " 0 0 . 0 3 1 ' E " 0 0 0 0 . 0 1 S 31'-1" EXISTING 25" DIAMETER LIVE OAK TREE IN NEIGHBORS YARD. EXISTING FENCE BETWEEN PROPERTIES TO REMAIN. TREE IS 39' FROM PROPOSED SITE WORK NO CERTIFIED TREE PERMIT REQUIRED PER EMAIL FROM HEATHER BERRYMAN JAN 7TH, 2021 AC W ' " 0 0 0 0 . 0 1 N EXISTING SINGLE STORY WITH NEW ADDITION COVERED PORCH 25' FRONT SETBACK EXISTING FENCE GRAVEL DRIVE TO REMAIN EXISTING FENCE GRAVEL DRIVE TO REMAIN S 80.00'00" W S 79.59'58" W S 80.00'00" W S 79.59'58" W EXISTING FENCE EXISTING FENCE ET PP ET PP PROPOSED TOTAL GROSS FLOOR AREA = 37.35% OF LOT (40% ALLOWED) 1 Proposed Plan Scale: ET MATERIAL STAGING AND DUMPSTER LOCATED IN EXISTING DRIVEWAY SPOILS PLACEMENT, PORTABLE TOILET AND CONCRETE WASHOUT ALL IN THIS ZONE PROPOSED TOTAL IMPERVIOUS COVER: 2346.5 SQ FT = 39% OF LOT (45% ALLOWED) 1 Existing Plan Scale: ET © Fox Fox Studio, LLC ------------------------------------- Will Fox 512.925.0375 - will@foxfoxstudio.com e c n e d i s e R n a n s o r t B c e o r P j 2 0 7 8 7 s a x e T n i t s u A t e e r t S n o s i r r a H b o B 4 0 3 1 Permit Set Issue Date 3/4/2021 Revision Date 1/8" = 1'-0" 11X17 SHEET 1/16" = 1'-0" 11X17 SHEET 1/8" = 1'-0" 22X34 SHEET 1/4" = 1'-0" 22X34 SHEET Sheet Title PLANS Sheet Number A1.0 Existing House Foot Print (without porches) = 135' Max Removal Allowed - 67.5' (50%) Demolished Walls Shown = 48' 30'-8" REMOVE DECK 3% SLOPE TPO BEDROOM 8'-.5" clg BATH 8'-1.5" clg UTILITY 8'-0" clg BEDROOM 8'-8.75" clg KITCHEN 8'-10.25" clg " 6 - ' 8 " 6 - ' 8 2 " 0 - ' 2 1 " 0 - ' 5 2 BEDROOM 8'-8.5" clg LIVING ROOM 8'-9.5" clg EXISTING WALLS TO REMAIN " 0 1 - ' 5 REMOVE PORCH 14'-2" 3% SLOPE TPO NEW SKYLIGHT 3% SLOPE TPO NEW SKYLIGHT SHADED SHOWS ADDITION ALL ROOFS WILL BE NEW TPO OR METAL 3:12 SLOPE 3:12 SLOPE EXISTING SLOPE EXISTING SLOPE (3:12) NEW SKYLIGHT E P O L S G N T S X E I I E P O L S G N T S X E I I NEW SKYLIGHT 3% SLOPE TPO 1 Demolition Floor Plan Scale: 2 Proposed Roof Plan Scale: © Fox Fox Studio, LLC ------------------------------------- Will Fox 512.925.0375 - will@foxfoxstudio.com e c n e d i s e R n a n s o r t B c e o r P j 2 0 7 8 7 s a x e T n i t s u A t e e r t S n o s i r r a H b o B 4 0 3 1 Permit Set Issue Date 3/4/2021 Revision Date 1/8" = 1'-0" 11X17 SHEET 1/4" = 1'-0" 22X34 SHEET Sheet Title Demolition Floor Plan Sheet Number A2.0 13 3 5 4 11 11 MTL-1 TOP PLATE EXISTING +9'-7" TOP PLATE +10'-0" 003 004 005 007 7 1 10 2 1 11 MTL-1 8 Elevation & Section General Notes: 1. 2. 3. 4. 5. 6. 7. 8. 9. The dimensions on this sheet are based off of the face of finish material or masonry. All dimensions are to face of finish material, edge of awning, or centerline of support, unless otherwise noted. Contractor (GC) to field verify all dimensions prior to construction and/or installation of any equipment, accessories, etc. If a discrepancy is identified, notify Fox Fox Studio immediately. Elevations are shown for reference only. Refer to Building Plans, Sections, Wall Sections and Window Elevations for additional information. All glass to be tempered in areas required by applicable code. Refer to appropriate sheet and/or schedule for additional information/detail regarding items shown herein. Keynotes located on this sheet are for this sheet only. Do not scale the drawings. If a specific dimension is not given, contact Fox Fox Studio for clarification. Refer to Sheet A0.1-General Conditions for additional information associated with, but not limited to: submittals, shop drawings, samples, cutting and patching, coordination and staging, protection of work. Install all products per manufacturer's recommendations. Fox Fox Studio, LLC ------------------------------------- Will Fox 512.925.0375 - will@foxfoxstudio.com TOP OF PARAPET +19'-4" TOP PLATE +18'-1" TOP OF PARAPET +12'-5" TOP PLATE +8'-5" Elevation & Section Keynotes: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. Replacement window Existing wood siding and trim, repaired and painted Replace existing asphault roof with new metal roofing TPO roofing membrane, 3% slope to scuppers Overframed roof cricket Scupper downspouts New covered concrete porch with new handrail and guardrail Concrete rear deck Skylight Stucco underpinning New Metal siding AC Existing chimney FINISH FLOOR EXISTING HOUSE +1'-1" TOP OF SLAB +0'-0" 1 West Elevation Scale: 1/4"=1'-0" TOP OF PARAPET +19'-4" TOP PLATE +18'-1" TOP OF PARAPET +12'-5" TOP PLATE +8'-5" " 0 1 - ' 9 1 4 MTL-1 5 3 4 014 7 12 008 009 010 011 PORTION THREE HIGH POINT +560.5' AVERAGE ADJACENT GRADE = 558.25'+559.9 / 2= 559.07' PORTION TWO HIGH POINT +559.9 TOP OF SLAB +0'-0" FINISH FLOOR EXISTING HOUSE +1'-1" AVERAGE ADJACENT GRADE = 558.25'+559.9 / 2= 559.07' PORTION ONE HIGH POINT +558.25' 18'-31 8" 40'-0" 6 27'-7" 1 12 1 2 10 1 7 40'-0" 27'-107 8" 2 East Elevation Scale: 1/4"=1'-0" © e c n e d i s e R n a n s o r t B c e o r P j 2 0 7 8 7 s a x e T n i t s u A t e e r t S n o s i r r a H b o B 4 0 3 1 Permit Set Issue Date 3/4/2021 Revision Date 1/8" = 1'-0" 11X17 SHEET 1/4" = 1'-0" 22X34 SHEET Sheet Title Building Elevations Sheet Number A3.2 TOP PLATE +10'-0" 006 008 D110 MTL-1 11 8 1 South Elevation Scale: TOP OF PARAPET +19'-4" TOP PLATE +18'-1" TOP OF PARAPET +12'-5" TOP PLATE +8'-5" FINISH FLOOR EXISTING HOUSE +1'-1" TOP OF SLAB +0'-0" R E SID E N TIA L S T A N D A R D S B UIL DIN G E N V E L O P E MTL-1 11 013 " 0 - ' 2 3 3 TOP OF PARAPET +19'-4" TOP PLATE +18'-1" TOP OF PARAPET +12'-5" TOP PLATE EXISTING +9'-7" +8'-5" TOP PLATE 002 1 FINISH FLOOR EXISTING HOUSE +1'-1" TOP OF SLAB +0'-0" 2 North Elevation Scale: " 0 - ' 5 1 012 001 D101 AVERAGE ADJACENT GRADE = 558.25'+559.9 / 2= 559.07' 10 2 1 7 © Elevation & Section General Notes: 1. 2. 3. 4. 5. 6. 7. 8. 9. The dimensions on this sheet are based off of the face of finish material or masonry. All dimensions are to face of finish material, edge of awning, or centerline of support, unless otherwise noted. Contractor (GC) to field verify all dimensions prior to construction and/or installation of any equipment, accessories, etc. If a discrepancy is identified, notify Fox Fox Studio immediately. Elevations are shown for reference only. Refer to Building Plans, Sections, Wall Sections and Window Elevations for additional information. All glass to be tempered in areas required by applicable code. Refer to appropriate sheet and/or schedule for additional information/detail regarding items shown herein. Keynotes located on this sheet are for this sheet only. Do not scale the drawings. If a specific dimension is not given, contact Fox Fox Studio for clarification. Refer to Sheet A0.1-General Conditions for additional information associated with, but not limited to: submittals, shop drawings, samples, cutting and patching, coordination and staging, protection of work. Install all products per manufacturer's recommendations. Fox Fox Studio, LLC ------------------------------------- Will Fox 512.925.0375 - will@foxfoxstudio.com Elevation & Section Keynotes: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. Replacement window Existing wood siding and trim, repaired and painted Replace existing asphault roof with new metal roofing TPO roofing membrane, 3% slope to scuppers Overframed roof cricket Scupper downspouts New covered concrete porch with new handrail and guardrail Concrete rear deck Skylight Stucco underpinning New Metal siding AC Existing chimney e c n e d i s e R n a n s o r t B c e o r P j 2 0 7 8 7 s a x e T n i t s u A t e e r t S n o s i r r a H b o B 4 0 3 1 Permit Set Issue Date 3/4/2021 Revision Date 1/8" = 1'-0" 11X17 SHEET 1/4" = 1'-0" 22X34 SHEET Sheet Title Building Elevations Sheet Number A3.1