Historic Landmark CommissionDec. 14, 2020

C.4.1 - 1601 Woodlawn Boulevard - Plans — original pdf

Backup
Thumbnail of the first page of the PDF
Page 1 of 4 pages

I G N V L E H S N E P O AE LIBRARY WOOD EQ EQ DW MUD/PANTRY WOOD PANTRY 24" FREEZE 30" REF. DRAWERS BELOW STAIRS T U O L L U P S R E W A R D 7 3/4" PORCH CONCRETE 7 3/4" 7 3/4" DN FOYER WOOD UP 17R DINING ROOM WOOD NEW A/C H S A R T KITCHEN WOOD SCREEN PORCH WOOD . . . PATIO DECK DN A/C BATH HALL UTILITY DRY WASH T E S O L C CAB. GUEST BATH NOT IN SCOPE BATH 1 NOT IN SCOPE E G A R O T S E G A R O T S M O O R B CAB. S A G W E N E C A L P E R F I GUEST ROOM WOOD NEW A/C EXISTING A/C : M P 7 3 : 4 4 2 0 2 0 2 4 / 1 1 / LIVING ROOM WOOD P O O L ROOF LINE ABOVE LINE OF ADDITION DRAWING LEGEND EXISTING CONSTRUCTION NEW CONSTRUCTION NEW CONCRETE WALL WOOD FLOORING WOOD DECKING TILE CONCRETE LOT SIZE: 8,257 SF FAR - IMPERVIOUS - ____________________________________________________ 3,302 SF (40%) 3,715 SF (45%) FIRST FLOOR - SECOND FLOOR - FINAL - 1,727 SF 1,540 SF 3,267 SF (40%) 1 FIRST FLOOR PLAN - PROPOSED 1/4" = 1'-0" TRUE PROJECT arthur@sideangleside.co NOT FOR CONSTRUCTION 11.04.18 FIELD INSPECTION REQUIRED Prior to performing any bidding, new construction, and/or repairs, general contractor shall visit the site, inspect all existing conditions, and report any discrepancies to the architect. N W A L D O O W 3 0 7 8 7 , S A X E T , I N T S U A , D V L B N W A L D O O W 1 0 6 1 ISSUE SETS DATE DESCRIPTION 11.04.18 BANK SET 11.04.18 FIRST FLOOR PLAN A1.3 STANDING SEAM, FLAT PAN METAL, 12" O.C. LINE OFROOF ABOVE " 0 - ' 2 H C N E B N I T L U B I BEDROOM 1 WOOD H C N E B BATH 2 TILE T E S O L C T E S O L C LINEN HALL WOOD OPEN TO BELOW 36" PONY WALL MEDICINE CABINETS T E S O L C T E S O L C 2 BEDROOM 2 WOOD J MED. CABINET IN 54" PONY WALL DN 17R T E S O L C N E N L I M. BATH TILE SHOWER W.C. DEN WOOD T.V. MASTER BEDROOM WOOD S S E R G E W D W P O P O O L DRAWING LEGEND EXISTING CONSTRUCTION NEW CONSTRUCTION NEW CONCRETE WALL WOOD FLOORING WOOD DECKING TILE CONCRETE LOT SIZE: 8,257 SF FAR - IMPERVIOUS - ____________________________________________________ 3,302 SF (40%) 3,715 SF (45%) FIRST FLOOR - SECOND FLOOR - FINAL - 1,727 SF 1,540 SF 3,267 SF (40%) 1 SECOND FLOOR PLAN - PROPOSED 1/4" = 1'-0" TRUE PROJECT arthur@sideangleside.co NOT FOR CONSTRUCTION 11.04.18 FIELD INSPECTION REQUIRED Prior to performing any bidding, new construction, and/or repairs, general contractor shall visit the site, inspect all existing conditions, and report any discrepancies to the architect. N W A L D O O W 3 0 7 8 7 , S A X E T , I N T S U A , D V L B N W A L D O O W 1 0 6 1 ISSUE SETS DATE DESCRIPTION 11.04.18 BANK SET 2 11.04.18 SECOND FLOOR PLAN A1.4 : M P 9 3 : 4 4 2 0 2 0 2 4 / 1 1 / GUTTER, RE: SPEC., CONFIRM W/ OWNER & ARCHITECT FOR D.S. LOCATIONS 12 3 12 5 1' - 0" TYP. " 0 - ' 7 " 2 / 1 0 - ' 4 1' - 6" 2' - 6" " 4 / 1 4 - ' 6 2 T H G E H I I G N D L U B I " 2 / 1 9 " 0 - ' 8 " 6 - ' 1 " 0 - ' 9 NEW SCREEN PORCH " 0 - ' 3 100' - 3 1/2" ELECTRIC AND GAS METER LOCATIONS LOWEST POINT GREEN ROOF 2 SOUTH ELEVATION 1/4" = 1'-0" T.O. 2ND FLOOR PLATE 121' - 0" T.O. SUB FLOOR 113' - 0" T.O. PLATE 111' - 6" T.O. EXISTING PLATE 110' - 8 1/2" FFL 102' - 6" AVERAGE GRADE 100' - 7 1/2" arthur@sideangleside.co NOT FOR CONSTRUCTION 11.04.18 FIELD INSPECTION REQUIRED Prior to performing any bidding, new construction, and/or repairs, general contractor shall visit the site, inspect all existing conditions, and report any discrepancies to the architect. N W A L D O O W 3 0 7 8 7 , S A X E T , I N T S U A , D V L B N W A L D O O W 1 0 6 1 ISSUE SETS DATE DESCRIPTION 11.04.18 BANK SET 12 9 12 9 NEW STANDING SEAM METAL ROOF, TYP. PTD. WOOD SIDING,TYP. GREEN ROOF, BEYOND 1' - 6" GUTTER, RE: SPEC., CONFIRM W/ OWNER & ARCHITECT FOR D.S. LOCATIONS DOWN SPOUT EXISTING BOARD & BATTEN WOOD SIDING 1 WEST ELEVATION 1/4" = 1'-0" T.O. 2ND FLOOR PLATE 121' - 0" T.O. SUB FLOOR 113' - 0" T.O. PLATE 111' - 6" T.O. EXISTING PLATE 110' - 8 1/2" " 2 / 1 9 2 " 0 - ' 8 " 6 - ' 1 " 0 - ' 9 FFL 102' - 6" AVERAGE GRADE 100' - 7 1/2" 11.04.18 ELEVATIONS A2.0 " 8 - ' 6 NEW STEEL AND GLASS DOOR REUSE EXISTING STEEL COLUMN 100' - 3 1/2" LOWEST POINT " 8 - ' 6 DOWN SPOUT DRYER VENT " 0 - ' 7 2' - 8 3/4" OVERHANG DOWN SPOUT " 8 - ' 6 100' - 3 1/2" : M P 6 4 : 4 4 2 0 2 0 2 4 / 1 1 / 1' - 0" TYP. " 0 - ' 7 " 0 - ' 7 " 0 - ' 6 1' - 0" TYP. 1' - 6" 101' - 0" 4' - 6 1/4" HIGHEST GRADE AT BUILDING NEW SCREEN PORCH STUCCO " 4 - ' 2 " 8 - ' 3 " 0 - ' 9 " 0 - ' 9 " 0 - ' 5 " 0 - ' 7 11' - 1 1/2" . . " 0 - ' 3 SCREEN PORCH STUCCO T.O. 2ND FLOOR PLATE 121' - 0" T.O. SUB FLOOR 113' - 0" T.O. PLATE 111' - 6" T.O. EXISTING PLATE 110' - 8 1/2" FFL 102' - 6" AVERAGE GRADE 100' - 7 1/2" " 0 - ' 8 " 6 - ' 1 " 0 - ' 9 " 2 / 1 9 : M P 2 5 : 4 4 2 0 2 0 2 4 / 1 1 / 100' - 3 1/2" 100' - 3 1/2" STUCCO 1 EAST ELEVATION 1/4" = 1'-0" arthur@sideangleside.co T.O. 2ND FLOOR PLATE 121' - 0" NOT FOR CONSTRUCTION " 4 / 1 4 - ' 6 2 I T H G E H G N D L U B I I " 2 / 1 9 " 0 - ' 8 " 6 - ' 1 " 0 - ' 9 T.O. SUB FLOOR 113' - 0" T.O. PLATE 111' - 6" T.O. EXISTING PLATE 110' - 8 1/2" FFL 102' - 6" AVERAGE GRADE 100' - 7 1/2" 2 NORTH ELEVATION 1/4" = 1'-0" 11.04.18 FIELD INSPECTION REQUIRED Prior to performing any bidding, new construction, and/or repairs, general contractor shall visit the site, inspect all existing conditions, and report any discrepancies to the architect. N W A L D O O W 3 0 7 8 7 , S A X E T , I N T S U A , D V L B N W A L D O O W 1 0 6 1 ISSUE SETS DATE DESCRIPTION 11.04.18 BANK SET 11.04.18 ELEVATIONS A2.1