B.2 - Seaholm Intake Building - Wall sconce specs — original pdf
Backup
Wall Mount LED Wall Sconce 101L Project: Location: Cat.No: Type: Lamps: Notes: Qty: Gardco 101 LED wall sconces feature a low-profile design that provides wide flexibility in high performance exterior wall illumination. Full cutoff performance, usable illumination patterns, and powerful wattages combine into a compact and architecturally pleasing design. 101L sconces are available in Type 2, 3, and 4 distributions, and provide output of up to 9500 lumens. Energy saving control options increase energy savings and offer California Title 24 compliance. Emergency Battery Backup option available for path of egress. Ordering guide example: 101L-32L-700-NW-G1-3-120-IMRI2-BZ Number of LEDs LED Color - Generation Drive Current Distribution Emergency Voltage Controls Electrical Finish Options Prefix 101L 101L 101L LED Wall Sconce 16L 16 LEDs (1 module) 530 530 mA 650 650 mA 1 700 700 mA CW-G1 Cool White 5700K, 70 CRI Generation 1 2 Type 2 3 Type 3 4 Type 4 UNV 120-277V HVU 347-480V 0-10V Dimming Driver 5,6 DD DCC Dual Circuit Control 6,7,8 Fusing Textured F1 Single (120, 277, 347VAC) 12 F2 Double (208, 240, 480VAC) 12 F3 Canadian Double Pull (208, 240, 480VAC) 12 BK Black WH White BZ Bronze DGY Dark Gray MGY Medium Gray EBPC Emergency Battery Pack Cold Weather 3,4,6,12 Leave blank to omitt an emergency option 120 120V 208 208V 240 240V 277 277V 347 347V 480 480V 32L 32 LEDs (2 module) 1000 1000 mA 1200 1200 mA 530 530 mA 650 650 mA 1 700 700 mA 1000 1000 mA 2 NW-G1 Neutral White 4000K, 70 CRI Generation 1 WW-G1 Warm White 3000K, 70 CRI Generation 1 Customer specified RAL Specify CC optional color or RAL (ex: OC-LGP or OC-RAL7024) Custom color (Must supply color chip for required factory quote) DynaDimmer: Automatic Profile Dimming CS50 Safety 50% Dimming (7 hours) 7,9,10 CM50 Median 50% Dimming (8 hours) 7,9,10 CE50 Economy 50% Dimming (9 hours) 7,9,10 DA50 All Night 50% Dimming 7,9,10 Photoelectric/Receptacle systems (Twist Lock Receptacle) Photocontrol Button 5,10,11,12 PCB TLRD5 Twist Lock Receptacle 5-Pin 13 TLRD7 Twist Lock Receptacle 7-Pin 13 TLRPC Twist Lock Receptacle w/ Photocell 11,12,16 Infrared Motion Response systems IMRI2 Integral with #2 lens 9,12,14 IMRI3 Integral with #4 lens 9,12,14 Network system (SiteWise) SW SW Integral module 4,17 Wireless system LLC2 LLC3 Integral module with #2 lens 5,7,9,15 Integral module with #3 lens 5,7,9,15 1. 650mA only available with Emergency Battery Pack Cold 8. Available in 32L with 530mA. Consult technical support center 15. LLC2/3 Not available with TLR, PCB, IMRI, CS/CM/CE/DA. Rated (EBPC) option 2. 32L rated for 30°C at 1000mA 3. Available for use with 16L and 32L in 530mA or 650mA only. Rated for -20°C to 35° C. 4. Available in 120 or 277V only. 5. Not available with Dual Circuit Control (DCC) option. 6. EBPC is not available with DCC. 7. Not available with Dimming Driver (DD) option. for use with photocell and CS/CM/CE/DA. 9. Available in 120-277V (UNV) only. 10. Not available with LLC, TLR and DCC. 11. Not available with 480V. 12. Must specify input voltage. 13. TLRD5/7 option not available with LLC, PCB, DCC. Works with 3 or 5 pin NEMA photocell dimming. Dimming will not be connected to TLR if ordering with DD, CS/CM/CE/DA and IMRI. 14. Not available with DD, DCC or LLC. Ships with WS accessory attached to wireless module. Not for use with LLCR accessory. 16. Not available with PCB, TLRD5/7, DCC, LLC. 17. SW option is not available with any other control options with the exception of IMRI2, IMRI3 motion response options. 101L 10/18 page 1 of 7 101L Sconce LED Wall Mount Luminaire Accessories (order separately) Mounting accessories Wall Mount WS Wall Mounted Box for Surface Conduit Dimensions System accessories Wireless system remote mount module LLCR2-(F) #2 lens - specify finish in place of (F) LLCR3-(F) #3 lens - specify finish in place of (F) Central Remote Motion Response (used connected to SiteWise main panel) MS2-A-FVR-3 MS2-A-FVR-7 Wireless system remote controller accessory Wireless system offers a remote radio/sensor module that allows to connected to a Limelight system (sold by other). Remote module can be mounted to wall or pole with j-box supplied. May be specified by choosing one of two different lenses to accommodate a variety of mounting heights/sensor detection ranges. Must specify option DD on luminaires that are planned to be used with remote mount controllers. See page 4 for Wireless system details. Motion Response 16 3⁄8" (415 mm) 9" (229 mm) Wireless Controls 16 1⁄4" (413 mm) 9" (229 mm) 7 1⁄4" (184 mm) 7 3⁄4" (197 mm) 4 1⁄2" (114 mm) 8 3⁄4" (222 mm) 19 3⁄4" (502 mm) 10 1⁄2" (267 mm) Luminaire Weights LED Wall Sconce 101L Weight 13.5 lbs Luminaire Luminaire - EBPC (EM battery pack) 17.0 lbs Luminaire - Integrated system controls 16.3 lbs 101L 10/18 page 2 of 7 101L Sconce LED Wall Mount LED Wattage and Lumen Values Ordering Code 101L-16L-530-NW-G1 101L-16L-700-NW-G1 101L-16L-1000-NW-G1 101L-16L-1200-NW-G1 101L-32L-530-NW-G1 101L-32L-700-NW-G1 LED Current (mA) 530 700 Color Temp. 4000K 4000K 1000 4000K 1200 4000K 530 700 4000K 4000K LED Qty 16 16 16 16 32 32 32 28 37 55 65 52 70 Average System Watts 1 Lumen Output 1, 2 Type 2 BUG Rating Efficacy (LPW) Lumen Output 1, 2 Efficacy (LPW) Lumen Output 1, 2 Efficacy (LPW) Type 3 BUG Rating 2944 B1-U0-G0 3789 B1-U0-G1 2687 3458 B1-U0-G1 B1-U0-G1 5050 B1-U0-G1 4609 B1-U0-G1 5744 B2-U0-G1 5242 B1-U0-G2 5359 B1-U0-G2 5698 B2-U0-G1 5200 B1-U0-G2 100 B1-U0-G2 102 Type 4 BUG Rating B1-U0-G1 B1-U0-G1 B1-U0-G1 B1-U0-G2 B2-U0-G2 99 96 86 83 96 86 97 94 84 81 94 84 2747 3535 4712 5316 6757 9140 101L-32L-1000-NW-G1 1000 4000K 107 7242 9797 B2-U0-G1 B2-U0-G1 6609 B1-U0-G2 8941 B2-U0-G2 LED Wattage and Lumen Values (Emergency Mode)3 Ordering Code LED Qty LED Current (mA) Color Temp. Ave. System Watts (charging mode) Type 2 Type 3 Type 4 101L-16L-NW-EBPC 101L-32L-NW-EBPC 16 32 N/A N/A 4000K 4000K 1345 1754 1228 1600 1255 1636 1. Wattage and lumen output may vary by +/- 8% due to LED manufacturer forward volt specification and ambient temperature. Wattage shown is average for 120V through 277V input. Actual wattage may vary by an additional +/- 10% due to actual input voltage. 2. Lumen values based on photometric tests performed in compliance with IESNA LM-79. 3. For emergency EBPC option, publish values are based on initial lumens. 106 103 92 89 110 103 92 14 14 Luminaire options DD: 0-10V dimming driver with leads supplied through back of luminaire (for secondary dimming controls by others). Dynadimmer Automatic Profile Dimming: Automatic dimming profiles (CS50/CM50/ CE50) offer safety, median, or economy settings, for shorter or longer duration. Dimming profiles provide flexibility towards energy savings goals while optimizing light levels during specific dark hours. 50% dimming is standard. DA50 offers 50% instantaneous dimming all night (during all dark hours). Other dimming settings are also available if different light levels are required (contact Technical Support for details). Dimming Profile Economy Median Safety Schedule Duration Level 50% 9 PM - 6 AM 9 hours 10 PM - 6 AM 8 hours 11 PM - 6 AM 7 hours Reactive 50 all night dynamic 50% 50% 50% TLRD5: Twist Lock Receptacle with 5 pins enabling dimming, can be used with a twistlock photoelectric cell or a shorting cap. Can also be used with third party control system. TLRD7: Twist Lock Receptacle with 7 pins enabling dimming and additional functionality, can be used with twistlock photoelectric cell or a shorting cap. Can also be used with third party control system. TLRDPC: Receptacle with twistlock photoelectric cell (must specify voltage). Receptacle located on top of luminaire housing. IMRI2, IMRI3: Infrared Motion Response Integral (IMRI). IMRI module is mounted integral to the luminaire door and is available with two different sensor lens types to accommodate various mounting heights and occupancy detection ranges (see charts for approximate detection patterns). Motion response used in combination of Dynadimmer and SiteWise are not programmable and used to override controllers schedule when motion is detected. When used not combined with any controller, IMRI is set/operates in the following fashion: The motion sensor is set to a constant 50%. When motion is detected by the PIR sensor, the luminaire returns to 100% light output. Dimming on low is factory set to 50% with 5 minute default in "full power" prior to dimming back to low. When no motion is detected for 5 minutes, the motion response system reduces the wattage by 50% of the normal constant wattage reducing the light level. IMRI can also be specified with automatic profile dimming for the added benefit of a combined dimming profile with sensor detection, where the PIR sensor will override the dimming profile when occupancy is detected. Passive infrared (PIR) motion sensor, WattStopper FSP-211, equipped with lens choice specified. Available from 120V to 277V input only. Motion sensor off state power is 0.0 watts. The FSP-211 can also be reprogrammed with WattStopper’s FS1R-100 remote programming tool accessory. DCC: Dual Circuit Control permits separate switching of 32L models only, where a quantity of (2) 16 LED modules are controlled independently by use of two sets of leads, one for each module. SW SiteWise option is a fully integrated controller that connects to SiteWise system in order to offer a complete area lighting management system. The communication signal is based on patented central dimming technology. SiteWise delivers it deliver optimal energy savings using your site’s existing cabling. No additional wiring required, installation and commissioning are simple. An intuitive, mobile app makes it easy for authorized users to set schedules to meet site specific lighting needs, local regulations, and energy codes. Wireless system: 101L luminaires are available with optional wireless controllers ready to be connected to a Limelight system (sold by other). The system allows you to Wirelessly manage the entire site, independent lighting groups or individual luminaires while on-site or remotely. Based on a high density mesh network with an easy to use web-based portal, you can conveniently access, monitor and manage your lighting network remotely. Wireless System can be combined with site and area, pedestrian, and parking garage luminaires as well, for a completely connected outdoor. 101L 10/18 page 3 of 7 101L Sconce LED Wall Mount Luminaire options (continued) F1: Fusing Single (for 120, 277 or 347VAC) F2: Fusing Double (for 208, 240 or 480VAC) F3: Fusing Canadian Double Pull (for 208, 240 or 480VAC) Motion Response EBPC: Emergency battery pack is cold weather rated down to -20C (-4F) and integral to the luminaire , allowing for a consistent look between emergency and non-emergency sconces. A separate surface mount accessory box is not required. Dual light engines (32L) are wired in parallel, both operating in emergency mode to meet various redundancy lamp 16 3⁄8" (415 mm) requirements. Also available with single light engine (16L). Secondary driver with relay immediately detects AC power loss and powers luminaire for a minimum of 90 minutes from the time power is lost. (229 mm) 9" Infrared Motion Response and Wireless system sensor coverage patterns LLC2/3 Luminaire mounted controller IMRI2/LLC2/LLCR2 Controller attached to luminaire and Includes radio, photocell and motion sensor with #2 or #3 lens for 8-20' mounting heights. Wireless Controls 16 1⁄4" (413 mm) 9" (229 mm) 4 1⁄2" (114 mm) 24' '11 7' 3' 0' 3' 7' 11' '42 20' 10' 0' 10' 20' IMRI3/LLC3/LLCR3 19 3⁄4" (502 mm) 10 1⁄2" (267 mm) 7 1⁄4" (184 mm) 7 3⁄4" (197 mm) 44 ft 8 3⁄4" (222 mm) 40' 30' 20' 10' 0' 10' 20' 20' 10' 0' 10' 20' 20' Remote Mount Wireless Controller Controller Wireless Radio 20' 20' 18' 15' 12' 9' 6' 3' 0 3' 6' 9' 12' 15' 18' 20' 10' 0' 10' 20' 30' 27' 12' 6' 3' 0' 3' 6' 12' - 1.8 Watts max (no load draw) - Operating voltage 120-277 VAC RMS - Communicates using the ZigBee protocol 60' - Carries out dimming commands from Gateway - Reports ambient light readings to 1500 Ft-Cd - Transmission Systems Operating within the 20' band 2400-2483.5Mhz - ROHS Compliant 27' 30' 20' 12' 6' 0 6' 12' 20' 30' 30' 27' 20' 12' 6' 3' 0 3' 6' 12' 20' 27' 30' Photocell Motion Response - Ambient light photocell on - Detects motion through passive infrared every wireless radio that averages the light levels of up to 5 controllers for an accurate reading and optimal light harvesting activity. - Reports ambient light readings to 1500 Fc. sensing technology with three different lens configurations - Motion sensor coverage can be adjusted from a narrow to a wide detection range, which helps reduce false triggers to further increase energy savings. - Sensing profiles can be updated to adapt to activity levels in the environment, such as occupancy level, wind, and mounting height 0' 8' 0' 5' 10' 15' 20' 0' 10' 20' 30' 40' Used to extend the communication on site, to extend motion response and add other luminaires that are not pole mounted. Consult factory for more information. 101L 10/18 page 4 of 7 101L Sconce LED Wall Mount SiteWise system SiteWise system diagram SiteWise is a complete area lighting management system including a luminaire integrated controller, dimming signal transmitter cabinet, and locally accessible user interface. Installation and commissioning are simple. The cabinet communicates with the luminaires using a patented central dimming technology. The control signal is embedded on the existing electrical line – no new cabling is required. An intuitive, locally accessible interface makes it easy for authorized users to set schedules in order to meet site specific lighting needs, local regulations, and energy codes. LAN / WiFi Gateway Mains power Dimming signal transmitter and transformer Authorized user Parking lot SiteWise system interface SiteWise has an intuitive user interface that makes it easy to plan, edit, and implement lighting schedules for your site. Authorized users can access the interface via a local app. To ensure that only authorized users can access your lighting, SiteWise offers two user types, each with different permissions. An advanced user, or administrator, can set and edit schedules using the ten pre-set scenes, assign those schedules to calendar days, and check system status. For everyday use, a basic user can manually override a schedule that is currently running but cannot create or edit schedules. SiteWise system specifications The SiteWise system includes both luminaires and controls. The controls used for SiteWise are circuit load dependent. Required for a complete installation are the following SiteWise components: user interface, control kit, dimming signal transmitter cabinet, and dimming signal receiver located in the luminaire (SW option). Optional luminaire-integrated or external motion sensors may also be specified as required. Within the electrical closet, the control kit and dimming signal transmitter cabinet are installed into the electrical system between the existing breaker panel and the site luminaires. New LED luminaires containing the dimming signal receiver are installed on the site. Once completed, use of the interface allows for scheduling and override capabilities. Wireless access point and tablet should be supplied by others. Complete information on the control system can be found on the SiteWise website at philips.com/sitewise 101L 10/18 page 5 of 7 Hardware Wiring (supplied by others) All exposed screws shall be stainless and/or corrosion resistant and captive. Splices must be made in the junction box. Finish Optical System The advanced LED optical systems provide IES Types 2, 3, 4. Composed of high performance UV stabilized optical grade polymer refractor lenses to achieve desired distribution optimized to get maximum spacing, target lumens and a superior lighting uniformity. System is rated IP66. Performance shall be tested per LM-63, LM-79 and TM-15 (IESNA) certifying its photometric performance. Dark sky compliant with 0% uplight and U0 per IESNA TM-15. Five standard colors offered in textured black, white, bronze, dark gray and medium gray. Color in accordance with the AAMA 2604 standard. Application of polyester powder coat paint 2.5 mils minimum. The thermosetting resins provides a discoloration resistant finish in accordance with the ASTM D2244 standard, as well as luster retention in keeping with the ASTM D523 standard and humidity proof in accordance with the ASTM D2247 standard. RAL and custom color matching available. Driver High power factor of 90% min. Electronic driver, operating range 50/60 Hz. Auto adjusting universal voltage input from 120 to 277 VAC or 347 to 480 VAC rated for both application line to line or line to neutral, Class I, THD of 20% max. The current supplying the LEDs will be reduced by the driver if the driver experiences internal overheating as a protection to the LEDs and the electrical components. Output is protected from short circuits, voltage overload and current overload. Automatic recovery after correction. Standard built in driver surge protection of 2.5kV (min). Surge Protection Each luminaire is provided as standard with surge protector (designed SP1) tested in accordance with ANSI/IEEE C62.45 per ANSI/IEEE C62.41.2 Scenario I Category C High Exposure 10kV/5kA waveforms for Line Ground, Line Neutral and Neutral Ground, and in accordance with U.S. DOE (Department of Energy) MSSLC (Municipal Solid State Street Lighting Consortium) Model Specification for LED Roadway Luminaires Appendix D Electrical Immunity High Test Level 10kV / 5kA. LED Products Manufacturing Standard The electronic components sensitive to electrostatic discharge (ESD) such as light emitting diodes (LEDs) are assembled in compliance with EC61340-5-1 and ANSI/ESD S20.20 standards so as to eliminate ESD events that could decrease the useful life of the product. LED Useful Life Luminaire Useful Life accounts for LED lumen maintenance. Refer to IES files for energy consumption and delivered lumens for each option. Based on ISTMT in situ thermal testing in accordance with UL1598 and UL8750, LED LM-80/TM-21, expected to reach 100,000 + hours with >L70 lumen maintenance @ 25°C. Certifications and Compliance cULus Listed for Canada and USA suitable for wet locations when mounted downward facing. cULus Listed for Canada and USA suitable for damp locations when inverted upward facing when mounted in covered ceiling application. Emergency Battery Pack option is tested and listed to UL924 and CSA C22.2 No. 141-10 DesignLights Consortium qualified on models as listed on DLC QPL. Luminaire is rated for operation in ambient temperature of -40°C (-40°F) up to +40°C (+104°F). Limited Warranty 5-year limited warranty. See philips.com/ warranties for details and restrictions. Visit our eCatalog or contact your local sales representative for more information. 101L Sconce LED Wall Mount Specifications Housing Main body cast housing and back plate made of a low copper die cast Aluminum alloy for a high resistance to corrosion, 0.100" (2.5mm) minimum thickness. Hinged door allows access to driver and LED compartment. Mounting Mounting is completed through integral back plate that features a separate recessed feature for hook and lock quick mount plate that secures with two set screws from bottom of luminaire. Mounting plate is located in the center of the luminaire width and 3.5” above the luminaire bottom (lens down position). Luminaire ships fully assembled, ready to install. Light Engine Composed of 4 main components: Heat Sink / LED Module / Optical System / Driver. Electrical components are RoHS compliant. IP66 sealed light engines. LEDs tested by ISO 17025-2005 accredited lab in accordance with IESNA LM-80 guidelines extrapolations in accordance with IESNA TM-21. Metal core board ensures greater heat transfer and longer lifespan. Heat Sink Integral door/heat sink design made of low copper die cast Aluminum alloy for a high resistance to corrosion. LED Module Composed of high performance white LEDs. Color temperature as per ANSI/NEMA bin Neutral White, 4000K nominal (+/- 275K), CRI 70 Min. Available in other color temperatures including Cool White, 5700K and Warm White, 3000K. SiteWise Network System SiteWise system includes a controller fully integrated in the luminaire that enables the luminaires to communicate with a dimming signal transmitter cabinet located on site using patented central dimming technology. A locally accessible mobile app allows users to access the system and set functionalities such as ON/OFF, dimming levels and scheduling. SiteWise is available with motion response options in order to bring the light back to 100% when motion is detected. Additional functionalities are available such as communication with indoor lighting and connection to BMS systems. 101L 10/18 page 6 of 7 101L Sconce LED Wall Mount LED Performance Predicted lumen depreciation data1 Ambient Temperature (°C) Driver mA Calculated L70 hours1,2 L70 per TM-212,3 Lumen Maintenance % @ 60,000 hours 25°C up to 1200 mA >100,000 >60,000 88% 1. Predicted performance derived from LED manufacturer’s data and engineering design estimates, based on IESNA LM-80 methodology. Actual experience may vary due to field application conditions. 2. L70 is the predicted time when LED performance depreciates to 70% of initial lumen output. 3. Calculated per IESNA TM21-11. Published L70 hours limited to 6 times actual LED test hours. © 2019 Signify Lighting Holding B.V. All rights reserved. Signify reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. signify.com/luminaires Signify Lighting, North America Corp., 200 Franklin Square Drive, Somerset, NJ 08873 Tel. 855-486-2216 Signify Lighting, Canada Ltd., 281 Hillmount Rd, Markham, ON, Canada L6C 2S3 Tel. 800-668-9008 101L 10/18 page 7 of 7