Historic Landmark CommissionJune 22, 2020

B.3 - 3803 Avenue H - Plans — original pdf

Backup
Thumbnail of the first page of the PDF
Page 1 of 6 pages

ABBREVIATIONS AB ABV ACM ACOUS ACR AD ADH ADJ AFF AHJ ALT ALUM ANC ANOD ANSI AP APC APPROX ARCH ASPH ASSY ASTM ATTEN AUTO AV BD BEL BIT BLDG BLKG BM BMJ BN BODT BOST BOW BR BRKT BTM BTW BVL CB CDM CEM CEN CF CFL CFMF CG CH CIV CJ CL CLG CLOS CLR CMU CNTR CO COL COMP CONC COND CONST CONT CORR CPR CPT CRS CS CU CW CY D DATACOM DBL AIR BARRIER ABOVE ASBESTOS CONTAINING MATERIAL ACOUSTICAL ACRYLIC AREA DRAIN ADHESIVE ADJUSTABLE ABOVE FINISHED FLOOR AUTHORITY HAVING JURISDICTION ALTERNATE ALUMINUM ANCHOR, ANCHORED ANODIZED AMERICAN NATIONAL STANDARDS INSTITUTE ACCESS PANEL ARCHITECTURAL PRECAST CONCRETE APPROXIMATE ARCHITECT, ARCHITECTURAL ASPHALT, ASPHALTIC ASSEMBLY AMERICAN SOCIETY FOR TESTING AND MATERIALS ATTENUATION AUTOMATIC AUDIO VISUAL BOARD BELOW BITUMEN, BITUMINOUS BUILDING BLOCKING BEAM BUILDING MOVEMENT JOINT BULLNOSE BOTTOM OF DOUBLE TEE BOTTOM OF STEEL BOTTOM-OF-WALL BATHROOM BRACKET BOTTOM BETWEEN BEVELED CHALKBOARD CAVITY DRAINAGE MATERIAL CEMENT, CEMENTITIOUS CENTER CUBIC FOOT, CUBIC FEET COUNTERFLASHING COLD FORMED METAL FRAMING CORNER GUARD CHANNEL CIVIL CONTROL JOINT CENTER LINE CEILING CLOSET CLEAR CONCRETE MASONRY UNIT COUNTER CLEAN OUT COLUMN COMPRESSIBLE, COMPRESSED CONCRETE CONDITION CONSTRUCTION CONTINUOUS CORRIDOR COPPER CARPET, CARPETED COURSE, COURSES COUNTERSUNK CUBIC CURTAINWALL CUBIC YARD DEEP, DEPTH DATA AND COMMUNICATION DOUBLE DEG DF DIA DIM DISP DIST DN DP DR DRN DS DTL DW DWG DWR EA EIFS EJ EL ELEC ELEV ENCL EQ EQUIP ETR EW EWC EXH EXP EXST EXT FAB FACP FD FDV FE FEC FF FHC FHVC FBLKG FIN FIXT FLEX FLR FLSHG FNDN FO FP FRJ FRM FRT FSTN FT FTF FTW FUR FURN FUT FXD GA GALV GL GR GYP HARAW HB HC HDOW HDR HDWR HM HOR HR HT HTR DEGREE, DEGREES DRINKING FOUNTAIN DIAMETER DIMENSION DISPENSER DISTANCE DOWN DIMPOINT, DAMPPROOFING DOOR DRAIN DOWNSPOUT DETAIL DISHWASHER DRAWING DRAWER EACH EXTERIOR INSULATION AND FINISH SYSTEM EXPANSION JOINT ELEVATION ELECTRIC, ELECTRICAL ELEVATOR ENCLOSURE EQUAL EQUIPMENT EXISTING TO REMAIN EACH WAY ELECTRIC WATER COOLER EXHAUST EXPANSION EXISTING EXTERIOR FABRICATE, FABRICATED, FABRICATOR FIRE ALARM CONTROL PANEL FLOOR DRAIN FIRE DEPARTMENT VALVE FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FINISHED FLOOR FIRE HOSE CABINET FIRE HOSE AND VALVE CABINET FIREBLOCKING FINISH, FINISHED FIXTURE FLEXIBLNE FLOOR, FLOORING FLASHING FOUNDATION FACE OF FIREPROOFED, FIREPROOFING FIRE RESISTIVE JOINT FRAME, FRAMED, FRAMING FIRE RETARDANT TREATED FASTENER FOOT, FEET FLOOR-TO-FLOOR FLOOR-TO-WALL FURRING FURNITURE FUTURE FIXED GAUGE GALVANIZED GLASS, GLAZING GUARD, GUARDRAIL GYPSUM HOT FLUID-APPLIED RUBBERIZED ASPHALT WATERPROOFING HOSE BIBB HANDICAPPED HEAD-OF-WALL HEADER HARDWARE HOLLOW METAL HORIZONTAL HOUR, HANDRAIL HEIGHT HEATER HVAC HVY HWH ID IN INCL INSUL INT INV JAN JBOX JST JT KD KDAT KIT KS L LAD LAM LAT LAV LB, # LBS LF LIN LLH LLV LOC LS LT LVL LVR MACH MAS MAX MB MBR MECH MEMB MEP MFR MIFRC MIN MIR MISC MNRL MOD MTD MTL N NIC NO NSMF NTS OC OD OH OPCI OPOI PERF PL PLAM PLAS PLBG PLYWD PR PROV PT PTD PTN QTR HEATING, VENTILATING, AND AIR CONDITIONING HEAVY HOT WATER HEATER INSIDE DIAMETER INCH INCLUDE, INCLUDED, INCLUDING INSULATE, INSULATION INTERIOR INVERT JANITOR, JANITOR CLOSET JUNCTION BOX JOIST JOINT KILN DRIED KILN DRIED AFTER TREATMENT KITCHEN KNEE SPACE LONG, LENGTH LADDER LAMINATE, LAMINATED LATERAL LAVATORY POUND POUNDS LINEAR FOOT, LINEAR FEET LINEAR LONG LEG HORIZONTAL LONG LEG VERTICAL LOCATE, LOCATION LANDSCAPE, LANDSCAPING LIGHT LEVEL LOUVER MACHINE MASONRY MAXIMUM MARKERBOARD MEMBER MECHANICAL MEMBRANE MECHANICAL, ELECTRICAL, AND PLUMBING MANUFACTURER, MANUFACTURED MASTIC AND INTUMESCENT FIRE RESISTIVE COATING MINIMUM MIRROR MISCELLANEOUS MINERAL MODIFIED MOUNTED METAL NORTH NOT IN CONTRACT NUMBER NON-STRUCTURAL METAL FRAMING NOT TO SCALE ON CENTER OUTSIDE DIAMETER, OVERFLOW DRAIN OPPOSITE HAND OWNER PROVIDED, CONTRACTOR INSTALLED OWNER PROVIDED, OWNER INSTALLED PERFORATED PLATE PLASTIC LAMINATE PLASTER PLUMBING PLYWOOD PAIR PROVIDE PRESSURE TREATED PAINTED PARTITION QUARTER R RAD RCP RD REF REINF REM REQD RESIL REV RFG RM RO RR SAB SALV SBR SD SECT SF SFRM SGL SHT SHWR SIM SLNT SOF SQ SS STL STND STOR STRUCT SURF SUSP SYS T T&G TAS TB TBP TEL TEMP THRU TME TOC TODT TOST TOW TRK TV TWF TYP UIO UL UNDRLAY UNF VB VERT VEST VIF VNR W W/ W/D W/O WB WC WD WNDW WP WS WTW WWF WWM YD RISER RADIUS REFLECTED CEILING PLAN ROOF DRAIN REFER, REFERENCE REINFORCED REMOVE REQUIRED RESILIENT REVISION ROOFING ROOM ROUGH OPENING RESTROOM, RAILROAD SOUND ATTENUATION BLANKET SALVAGE SEALANT & BACKER ROD SIDE SECTION SQUARE FOOT, SQUARE FEET SPRAY APPLIED FIRE-RESISTIVE MATERIAL SINGLE SHEET SHOWER SIMILAR SEALANT SOFFIT SQUARE STAINLESS STEEL STEEL STAINED STORAGE, STOREFRONT STRUCTURAL SURFACE SUSPEND, SUSPENDED SYSTEM TREAD TONGUE AND GROOVE TEXAS ACCESSIBILITY STANDARDS TACKBOARD TILE BACKER PANEL TELEPHONE TEMPORARY THROUGH TO MATCH EXISTING TOP OF CONCRETE TOP OF DOUBLE TEE TOP OF STEEL TOP OF WALL TRACK TELEVISION THROUGH WALL FLASHING TYPICAL UNLESS INDICATED OTHERWISE UNDERWRITERS LABORATORIES UNDERLAYMENT UNFINISHED VAPOR BARRIER VERTICAL VESTIBULE VERIFY IN FIELD VENEER WIDE, WIDTH WITH WASHER AND DRYER WITHOUT WALL BOARD WATER CLOSET WOOD WINDOW WORKPOINT, WATERPROOFING WATERSTOP WALL-TO-WALL WELDED WIRE FABRIC WELDED WIRE MESH YARD MATERIALS LEGEND SYMBOLS LEGEND GENERAL NOTES DRAWING INDEX GENERAL G011 1 TITLE SHEET ARCHITECTURAL A111 A121 A211 A221 A231 A233 A241 A312 A411 A431 A611 A612 A711 A811 DEMO SITE PLAN SITE PLAN LEVEL 1 & LEVEL 2 DEMO FLOOR PLANS LEVEL 1 DEMO REFLECTED CEILING PLANS LEVEL 1 & LEVEL 2 FLOOR PLANS ROOF PLAN LEVEL 1 & LEVEL 2 REFLECTED CEILING PLANS AND POWER PLANS EXTERIOR ELEVATION DETAILS BUILDING SECTIONS STAIR DETAILS EXTERIOR DETAILS EXTERIOR DETAILS INTERIOR ELEVATIONS WINDOW AND DOOR TYPES & SCHEDULES STRUCTURAL S0.0 S1.0 S1.1 S2.0 S2.1 S2.2 S2.3 GENERAL NOTES FOUNDATION PLAN & WIND BRACING PLAN ROOF FRAMING PLAN & 1ST FLOOR CEILING FRAMING PLAN DETAILS DETAILS TYPICAL DETAILS TYPICAL DETAILS 1301 E. 7th Street Austin, TX 78702 ph: 512 476 0201 fx: 512 476 0216 www.mckinneyyork.com CONTACT: MICHELLE ROSSOMANDO GIST E R E D AR LL E R OSS O C H I T E R E H C I M S T 180 0 5 A T E FO E C T M A N D O SA X E T 01/21/2020 MICHELLE ROSSOMANDO 01/21/2020 STRUCTURAL ENGINEER: FORT STRUCTURES PH: 512-817-9264 CONTACT: SAM COVEY STONE CONCRETE EARTH PLYWOOD WOOD ALUMINUM STEEL WALL BOARD PLASTER SPRAY FOAM CONCRETE BLOCK EXECUTIVE OFFICE 510 1 10/10/10 ROOM NAME & NUMBER REFERENCE REVISION REFERENCE - SEE REVISION SCHEDULE IN TITLEBLOCK OF THE SHEET WHERE REFERENCE IS INDICATED DIMENSION POINT SYMBOL - DIMENSIONS INDICATED IN PLAN AND SECTION DRAWINGS REFERENCE EXACT LOCATIONS INDICATED BY DIMENSION POINT SYMBOLS WHEN USED IN DETAIL DRAWINGS WORK POINT SYMBOL - DIMENSIONS INDICATED IN PLAN AND SECTION DRAWINGS REFERENCE EXACT LOCATIONS INDICATED BY WORK POINT SYMBOLS WHEN USED IN DETAIL DRAWINGS FINISH START POINT SYMBOL - LOCATION INDICATES A SEPARATION POINT OF TWO FINISHES OR AN ORIGIN POINT FOR ONE FINISH WHERE A FULL FORMAT PATTERN STARTS AND PROCEEDS IN THE DIRECTION OF THE ARROW DIRECTION SYMBOL - ARROWS INDICATE DIRECTION OF GRAIN, PLANK, OR SPAN JOINT FORMING MATERIAL LEVEL 1 TOSL 100'-0" 100'-0" 1" ELEVATION SYMBOL SPOT ELEVATION SYMBOL ELEVATION CHANGE SYMBOL EXTERIOR ELEVATION REFERENCE WALL SECTION REFERENCE BUILDING SECTION REFERENCE MATCHLINE REFERENCE DETAIL REFERENCE DETAIL REFERENCE 1/A101 1/A102 8/A922 1 A101 TITLE SCALE A101 01 DRAWING TITLE - THE DRAWING NUMBER REFERS TO THE DRAWING, THE SHEET NUMBER REFERS TO THE SHEET FROM WHICH THE DRAWING IS FIRST REFERENCED 4 A101 2 INTERIOR ELEVATION REFERENCE X PHOTOGRAPH REFERENCE - INDICATES APPROXIMATE LOCATION AND DIRECTION OF REFERENCED PHOTOGRAPH 1 1 1 A101 A101 A101 1 3 X Y W B F PT-1 RA-1 T-1 PT-1 14C EW-1 PS-1 W-1 SE-1 100 A 100 1 A.1 A.1 100 150 PANIC 100 N CONFERENCE A : 15 100 SF 7 ROOM FINISH CALLOUT - SPACE WHERE CALLOUT IS LOCATED HAS WALL FINISH PT-1, BASE RA-1, AND FLOOR FINISH T-1 ON ALL SURFACES, UNLESS INDICATED OTHERWISE SURFACE FINISH CALLOUT - SURFACE THAT CALLOUT IS LOCATED ON OR IS POINTING TO HAS FINISH PT-1 PARTITION & CEILING CALLOUT - NUMBER INDICATES PARTITION OR CEILING TYPE, LETTER INDICATES SIZE ACCORDING TO PARTITION SIZE SCHEDULE CONSTRUCTION ASSEMBLY CALLOUT SIGN CALLOUT FENESTRATION CALLOUT FURNITURE & FURNISHINGS REFERENCE EQUIPMENT REFERENCE ACCESSORIES REFERENCE DOOR REFERENCE KEY NOTE REFERENCE - SEE KEY NOTES ON THE SHEET WHERE REFERENCE IS INDICATED OCCUPANCY TYPE : OCCUPANT LOAD FACTOR EXISTING COLUMN GRID TAG NEW COLUMN GRID TAG OCCUPANCY DESCRIPTION OCCUPANT LOAD TOTAL FLOOR AREA EGRESS DIRECTION EXIT LOAD (OCCUPANTS) EXIT CAPACITY (OCCUPANTS) PANIC HARDWARE (WHERE OCCURS) EGRESS DIRECTION OCCUPANTS TRUE NORTH PLAN NORTH 1. 2. 3. 4. 5. 6. 7. 8. 9. 1. 2. 3. 4. 5. 6. DIMENSIONS GOVERN. DO NOT SCALE DRAWINGS. THE INTENT OF THE CONTRACT DOCUMENTS IS TO INCLUDE ALL ITEMS NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK BY THE CONTRACTOR. THE CONTRACT DOCUMENTS ARE COMPLEMENTARY, AND WHAT IS REQUIRED BY ONE SHALL BE AS BINDING AS IF REQUIRED BY ALL; PERFORMANCE BY THE CONTRACTOR SHALL BE REQUIRED ONLY TO THE EXTENT CONSISTENT WITH THE CONTRACT DOCUMENTS AND REASONABLY INFERABLE FROM THEM AS BEING NECESSARY TO PRODUCE THE INDICATED RESULTS. UNLESS OTHERWISE STATED IN THE CONTRACT DOCUMENTS, WORDS THAT HAVE WELL-KNOWN TECHNICAL OR CONSTRUCTION INDUSTRY MEANINGS ARE USED IN THE DRAWINGS IN ACCORDANCE WITH SUCH RECOGNIZED MEANINGS. IN THE INTEREST OF BREVITY THE CONTRACT DOCUMENTS FREQUENTLY OMIT MODIFYING WORDS SUCH AS “ALL” AND “ANY” AND ARTICLES SUCH AS “THE” AND “AN”, BUT THE FACT THAT THE MODIFIER OR AN ARTICLE IS ABSENT FROM ONE STATEMENT AND APPEARS IN ANOTHER IS NOT INTENDED TO AFFECT THE INTERPRETATION OF EITHER STATEMENT. EXECUTION OF THE CONTRACT BY THE CONTRACTOR IS A REPRESENTATION THAT THE CONTRACTOR HAS VISITED THE SITE, BECOME GENERALLY FAMILIAR WITH THE LOCAL CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED AND CORRELATED PERSONAL OBSERVATIONS WITH REQUIREMENTS OF THE CONTRACT DOCUMENTS. BECAUSE THE CONTRACT DOCUMENTS ARE COMPLEMENTARY, THE CONTRACTOR SHALL, BEFORE STARTING EACH PORTION OF THE WORK, CAREFULLY STUDY AND COMPARE THE VARIOUS CONTRACT DOCUMENTS RELATIVE TO THAT PORTION OF THE WORK, AS WELL AS THE INFORMATION FURNISHED BY THE OWNER, SHALL TAKE FIELD MEASUREMENTS OF ANY EXISTING CONDITIONS RELATED TO THAT PORTION OF THE WORK, AND SHALL OBSERVE ANY CONDITIONS AT THE SITE AFFECTING IT. THESE OBLIGATIONS ARE FOR THE PURPOSE OF FACILITATING COORDINATION AND CONSTRUCTION BY THE CONTRACTOR AND ARE NOT FOR THE PURPOSE OF DISCOVERING ERRORS, OMISSIONS, OR INCONSISTENCIES IN THE CONTRACT DOCUMENTS; HOWEVER, THE CONTRACTOR SHALL PROMPTLY REPORT TO THE ARCHITECT ANY ERRORS, INCONSISTENCIES OR OMISSIONS DISCOVERED BY OR MADE KNOWN TO THE CONTRACTOR AS A REQUEST FOR INFORMATION IN SUCH FORM AS THE ARCHITECT MAY REQUIRE. IT IS RECOGNIZED THAT THE CONTRACTOR’S REVIEW IS MADE IN THE CONTRACTOR’S CAPACITY AS A CONTRACTOR AND NOT AS A LICENSED DESIGN PROFESSIONAL, UNLESS OTHERWISE SPECIFICALLY PROVIDED IN THE CONTRACT DOCUMENTS. THE CONTRACTOR IS NOT REQUIRED TO ASCERTAIN THAT THE CONTRACT DOCUMENTS ARE IN ACCORDANCE WITH APPLICABLE LAWS, STATUTES, ORDINANCES, CODES, RULES AND REGULATIONS, OR LAWFUL ORDERS OF PUBLIC AUTHORITIES, BUT THE CONTRACTOR SHALL PROMPTLY REPORT TO THE ARCHITECT ANY NONCONFORMITY DISCOVERED BY OR MADE KNOWN TO THE CONTRACTOR AS A REQUEST FOR INFORMATION IN SUCH FORM AS THE ARCHITECT MAY REQUIRE. THE ARCHITECT AND THE ARCHITECT’S CONSULTANTS SHALL BE DEEMED THE AUTHORS AND OWNERS OF THEIR RESPECTIVE INSTRUMENTS OF SERVICE, INCLUDING THE DRAWINGS AND SPECIFICATIONS, AND WILL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING COPYRIGHTS. THE CONTRACTOR, SUBCONTRACTORS, SUB-SUBCONTRACTORS, AND MATERIAL OR EQUIPMENT SUPPLIERS SHALL NOT OWN OR CLAIM A COPYRIGHT IN THE INSTRUMENTS OF SERVICE. SUBMITTAL OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR OTHER PURPOSES IN CONNECTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THE ARCHITECT’S OR ARCHITECT’S CONSULTANTS’ RESERVED RIGHTS. THE CONTRACTOR, SUBCONTRACTORS, SUB-SUBCONTRACTORS AND MATERIAL OR EQUIPMENT SUPPLIERS ARE AUTHORIZED TO USE AND REPRODUCE THE INSTRUMENTS OF SERVICE PROVIDED TO THEM SOLELY AND EXCLUSIVELY FOR EXECUTION OF THE WORK. ALL COPIES MADE UNDER THIS AUTHORIZATION SHALL BEAR THE COPYRIGHT NOTICE, IF ANY, SHOWN ON THE INSTRUMENTS OF SERVICE. THE CONTRACTOR, SUBCONTRACTORS, SUB-SUBCONTRACTORS, AND MATERIAL OR EQUIPMENT SUPPLIERS MAY NOT USE THE INSTRUMENTS OF SERVICE ON OTHER PROJECTS OR FOR ADDITIONS TO THIS PROJECT OUTSIDE THE SCOPE OF THE WORK WITHOUT THE SPECIFIC WRITTEN CONSENT OF THE OWNER, ARCHITECT AND THE ARCHITECT’S CONSULTANTS. CUTTING AND PATCHING NOTES THE CONTRACTOR SHALL BE RESPONSIBLE FOR CUTTING, FITTING OR PATCHING REQUIRED TO COMPLETE THE WORK OR TO MAKE ITS PARTS FIT TOGETHER PROPERLY. ALL AREAS REQUIRING CUTTING, FITTING AND PATCHING SHALL BE RESTORED TO THE CONDITION EXISTING PRIOR TO CUTTING, FITTING AND PATCHING, UNLESS OTHERWISE REQUIRED BY THE CONTRACT DOCUMENTS. PATCH HOLES AND DAMAGED AREAS THAT ARE CREATED BY DEMOLITION OF ITEMS INDICATED ELSEWHERE. PATCH FINISH MATERIALS WHERE ITEMS ARE REMOVED. PATCH SUBSTRATES WHERE ITEMS ARE REMOVED. PATCH HOLES AND DAMAGED AREAS OF MASONRY, PLASTER, AND CONCRETE SURFACES THAT ARE CREATED BY DEMOLITION OF ITEMS MOUNTED WITH MECHANICAL FASTENERS, ADHESIVES, AND SETTING BEDS. REPLACE MASONRY WHERE CUTTING AND DEMOLITION EXPOSES MASONRY CORES. 7. WHERE EXCESSIVE CUTTING CANNOT BE AVOIDED AND PATCHING IS NOT FEASIBLE, REMOVE AND RECONSTRUCT ITEM TO MATCH EXISTING. PROJECT NOTES 1. WALL DIMENSIONS ARE TO THE FACE OF STUD, UNLESS INDICATED OTHERWISE. 2. PLAN ELEVATION OF 100'-0" IS EQUAL TO ACTUAL SURVEY ELEVATION OF 581.38' ABOVE SEA LEVEL. E C N E D I S E R L L A Y R - S N R A E K H E V A 3 0 8 3 2 5 7 8 7 S A X E T , I N T S U A PLEASE RECYCLE 1 2/27/2020 # REVISION DATE CONSTRUCTION DOCUMENTS PROJECT NO. DATE 1903 01/21/2020 TITLE SHEET G011 M P 1 1 : 4 1 : 3 0 2 0 2 / 6 2 / . 2 G W D 1 1 0 G ~ 3 0 S G N W A R D 0 I \ \ L E D O M E R L L A Y R - 3 0 9 1 \ : X I 5 1 0 2 S T C E T H C R A K R O Y Y E N N K C M © I W W W W W W W W W W W W W W W W W W W W W W ' 0 0 . 0 6 E " 0 0 0 0 º 0 3 N ' H E U N E V A W W W W W W W W W W W W X X X X X X X X X X X X X X X X X X X X X X X X X X S59º58'44" E 136.51' X X X X X X X X X X X X X X X X X REMOVE WOOD PORCH X K C A B T E S " 0 - ' 5 25'-0" SETBACK REMOVE BRICK PAVERS 10'-0" SETBACK X EXISTING BRICK AND WOOD FRAMED RESIDENCE TO REMAIN REMOVE PATH EXISTING GARAGE TO REMAIN REMOVE EXISTING FENCE AND GATE X X X X X X X X SAW CUT DRIVEWAY AT APRON. EXISTING APRON TO REMAIN. " 0 - ' 5 K C A B T E S X X X X X REMOVE EXISTING CONCRETE DRIVEWAY N60º00'59" W 136.60' X X X X X X X X X X X X X DEMO SITE PLAN - ARCHITECTURAL SCALE: 1/8" = 1'-0" @ 22x34 | 1/16" = 1'-0" @ 11x17 01 N SITE DEMO LEGEND ' 1 9 . 9 5 W ' " 4 4 4 5 º 9 2 S X X X X X X X X X X X X X X X X M P 7 1 : 4 1 : 3 0 2 0 2 / 6 2 / . 2 G W D 1 1 1 A - 3 0 S G N W A R D 0 I \ \ L E D O M E R L L A Y R - 3 0 9 1 \ : X I 5 1 0 2 S T C E T H C R A K R O Y Y E N N K C M © I SITE DEMO NOTES 1. 2. 3. REMOVE, REMOVE AND SALVAGE, AND REMOVE AND REINSTALL ITEMS INDICATED GRAPHICALLY ACCORDING TO DEMOLITION LEGEND AND AS INDICATED. DEMOLISH AND REMOVE EXISTING CONSTRUCTION ONLY TO THE EXTENT REQUIRED BY NEW CONSTRUCTION AND AS INDICATED. REMOVE AND REINSTALL ALL SURFACE MOUNTED ITEMS THAT ARE AFFECTED BY WORK AND NOT SPECIFICALLY INDICATED. 4. WHERE A SEAMLESS PATCH BETWEEN EXISTING AND NEW SURFACES AND ITEMS IS NOT POSSIBLE OR PRACTICAL, REMOVE ITEM BACK TO NEAREST JOINT OR CORNER AND REPLACE WITH NEW TO MATCH. 5. REMOVE ALL ABANDONED ITEMS EXPOSED BY DEMOLITION WORK. 6. WHERE ITEMS ARE INDICATED TO BE REMOVED, DETACH ITEMS FROM EXISTING CONSTRUCTION AND LEGALLY DISPOSE OF THEM OFF-SITE. 7. WHERE ITEMS ARE INDICATED TO BE REMOVED AND SALVAGED, CAREFULLY DETACH FROM EXISTING CONSTRUCTION IN A MANNER TO PREVENT DAMAGE, AND DELIVER TO OWNER. 8. WHERE ITEMS ARE INDICATED TO BE REMOVED AND REINSTALLED, DETACH ITEMS FROM EXISTING CONSTRUCTION, PREPARE FOR REUSE, AND REINSTALL WHERE INDICATED. 9. NOTIFY ARCHITECT OF DISCREPANCIES BETWEEN EXISTING CONDITIONS AND DRAWINGS BEFORE PROCEEDING WITH SELECTIVE DEMOLITION. 10. PERFORM AN ENGINEERING SURVEY OF CONDITION OF BUILDING TO DETERMINE WHETHER REMOVING ANY ELEMENT MIGHT RESULT IN STRUCTURAL DEFICIENCY OR UNPLANNED COLLAPSE OF ANY PORTION OF STRUCTURE OR ADJACENT STRUCTURES DURING SELECTIVE BUILDING DEMOLITION OPERATIONS. 11. PROVIDE AND MAINTAIN SHORING, BRACING, AND STRUCTURAL SUPPORTS AS REQUIRED TO PRESERVE STABILITY AND PREVENT MOVEMENT, SETTLEMENT, OR COLLAPSE OF CONSTRUCTION AND FINISHES TO REMAIN, AND TO PREVENT UNEXPECTED OR UNCONTROLLED MOVEMENT OR COLLAPSE OF CONSTRUCTION BEING DEMOLISHED. 12. PROTECT CONSTRUCTION INDICATED TO REMAIN AGAINST DAMAGE. 13. EXCEPT FOR ITEMS OR MATERIALS INDICATED TO BE RECYCLED, REUSED, SALVAGED, REINSTALLED, OR OTHERWISE INDICATED TO REMAIN OWNER'S PROPERTY, REMOVE DEMOLISHED MATERIALS FROM PROJECT SITE AND LEGALLY DISPOSE OF THEM IN AN EPA-APPROVED LANDFILL. 1301 E. 7th Street Austin, TX 78702 ph: 512 476 0201 fx: 512 476 0216 www.mckinneyyork.com CONTACT: MICHELLE ROSSOMANDO GIST E R E D AR LL E R OSS O C H I T E R E H C I M S T 180 0 5 A T E FO E C T M A N D O SA X E T 01/21/2020 MICHELLE ROSSOMANDO 01/21/2020 STRUCTURAL ENGINEER: FORT STRUCTURES PH: 512-817-9264 CONTACT: SAM COVEY E C N E D I S E R L L A Y R - S N R A E K H E V A 3 0 8 3 2 5 7 8 7 S A X E T , I N T S U A PLEASE RECYCLE CONSTRUCTION DOCUMENTS PROJECT NO. DATE 1903 01/21/2020 DEMO SITE PLAN A111 PROPERTY LINE EASEMENT SETBACK OVERHEAD UTILITIES X X FENCE WW WASTEWATER LINE ASPHALT DEMO GRAVEL DEMO BRICK DEMO CONCRETE EXISTING GAS METER EXISTING WATER METER EXISTING WATER VALVE UTILITY POLE EXISTING TREE G S M 100 TREE NUMBER (IF SHOWN) - REF SURVEY CRITICAL ROOT ZONE (CRZ) 1 2 CRZ (IF SHOWN) 4 CRZ (IF SHOWN) 1 EXISTING SEWER METER MANHOLE # REVISION DATE 25'-0" SETBACK 04 A311 X X X X X X X X X X W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W ' 0 0 . 0 6 E " 0 0 0 0 º 0 3 N ' H E U N E V A X X X X X X X X X X X X K C A B T E S " 0 - ' 5 01 A311 S59º58'44" E 136.51' X X EXIST AC COMPRESSOR X X X X X X X X X ADDITIONAL AC COMPRESSOR TBD X TANKLESS WATER HEATER X X X X X X X X X X 1. NOT USED. # KEY NOTES ADDITION EXISTING RESIDENCE LOOSE GRAVEL ON PERMEABLE WEED BLOCKER 03 A311 10'-0" SETBACK X CONCRETE PATIO EXISTING SHRUB, COORDINATE WITH OWNER LOOSE GRAVEL PATH ON PERMEABLE WEED BLOCKER EXISTING GARAGE, N.I.C. EXISTING CREPE MYRTLES P Y T " 3 , Q E . P Y T WD FENCE W CATTLE PANEL INFILL TME 10'-0" 8'-3" J C J C STEEL GATE W/ CATTLE PANEL INFILL: PROVIDE 180º WELD-ON HINGES WITH ZERK FITTINGS. COORD LATCH W/ OWNER. STEPPING PADS TO DRIVEWAY 8'-3" V.I.F. X V.I.F. X X 10'-0" X X 10'-0" X X 10'-0" 10'-0" 10'-0" E J E J JC E J JC E J E J JC E J JC E J JC E J CL E J JC E J E J E J E J 8'-3" 8'-3" EQ EQ EQ EQ 02 A311 10'-0" X JC X X X " 0 - ' 5 K C A B T E S X X N60º00'59" W 136.60' X X X X X X X X X X X X X PLEASE RECYCLE SITE PLAN - ARCHITECTURAL SCALE: 1/4" = 1'-0" @ 22x34 | 1/8" = 1'-0" @ 11x17 01 N AREA CALCULATIONS TREE SCHEDULE - PRESERVATION SITE NOTES 1. PROVIDE POSITIVE DRAINAGE AWAY FROM PERIMETER OF HOUSE. REMOVE VEGETATION WHERE NECESSARY. COORDINATE WITH ARCHITECT. I I N O T P R C S E D LOT AREA F S G N T S X E I I F S D E D D A W E N / R O T C A F F S L A T O T A E R A T O L F O % 8,226 100% IMPERVIOUS COVER CALCULATIONS HOUSE FOUNDATION DRIVEWAY EXISTING GARAGE FRONT ENTRY PATH REAR PATIO REAR STEPPING PADS BACK PORCH & STEPS 1,884 1,385 376 167 483 0 137 145 831 0 0 150 43 152 TOTAL NEW IMPERVIOUS COVER MAXIMUM ALLOWABLE IMPERVIOUS COVER EXISTING IMPERVIOUS COVER FLOOR AREA LEVEL 1 CONDITIONED AREA LEVEL 2 (CONDITIONED ATTIC) GARAGE COVERED BACK PORCH COVERED FRONT PORCH TOTAL FLOOR AREA MAXIMUM ALLOWABLE FLOOR AREA 1,884 0 376 0 0 145 1,652 0 0 135 1.00 1.00 1.00 1.00 1.00 1.00 0.50 1.00 0.00 1.00 0.00 0.00 2,029 833 376 167 129 43 76 3,653 3,702 4432 2,029 0 376 0 0 2,405 3,290 1301 E. 7th Street Austin, TX 78702 ph: 512 476 0201 fx: 512 476 0216 www.mckinneyyork.com CONTACT: MICHELLE ROSSOMANDO GIST E R E D AR LL E R OSS O C H I T E R E H C I M S T 180 0 5 A T E FO E C T M A N D O SA X E T 01/21/2020 MICHELLE ROSSOMANDO 01/21/2020 STRUCTURAL ENGINEER: FORT STRUCTURES PH: 512-817-9264 CONTACT: SAM COVEY E C N E D I S E R L L A Y R - S N R A E K H E V A 3 0 8 3 2 5 7 8 7 S A X E T , I N T S U A 44% 45% 54% 29% 40% ' 1 9 . 9 5 W ' " 4 4 4 5 º 9 2 S X X X X X X X X X X X X X X X X SITE LEGEND X X FENCE WW WASTEWATER LINE PROPERTY LINE EASEMENT SETBACK OVERHEAD UTILITIES GRAVEL GRAVEL CONCRETE EXISTING GAS METER EXISTING SEWER METER MANHOLE G S M EXISTING WATER METER EXISTING WATER VALVE UTILITY POLE EXISTING TREE 100 TREE NUMBER (IF SHOWN) - REF SURVEY CRITICAL ROOT ZONE (CRZ) 1 2 CRZ (IF SHOWN) 4 CRZ (IF SHOWN) 1 # REVISION DATE CONSTRUCTION DOCUMENTS PROJECT NO. DATE 1903 01/21/2020 SITE PLAN A121 M P 2 2 : 4 1 : 3 0 2 0 2 / 6 2 / . 2 G W D 1 2 1 A - 3 0 S G N W A R D 0 I \ \ L E D O M E R L L A Y R - 3 0 9 1 \ : X I 5 1 0 2 S T C E T H C R A K R O Y Y E N N K C M © I N D DN DN N D DN DN REMOVE ROOFING, ROOF DECK AND ROOF FRAMING IN THIS AREA, REF STUCTURAL. REMOVE ROOFING FOR TIE-IN, UNDERLAYMENT TO REMAIN N D N D N D N D DN N D DN N D DN DN PROVIDE 3 FIXED VELUX DECK MOUNTED SKYLIGHT, MODEL FS-M08-21-04 INSTALL PER MANUFACTURER'S INSTRUCTIONS, TYP. SHINGLE GRACE ICE AND WATER SHIELD AT ALL SIDES OF ROUGH OPENING OF SKYLIGHT, TYP. DN DN DN N D DN N D DN N D N D DN DN N D N D N D N D REMOVE ROOFING AND DECKING AS NECESSARY FOR SKYLIGHT TIE-IN, UNDERLAYMENT TO REMAIN. REF STRUCTURAL. DN DN DN N D N D DN N D ROOF PLAN LEGEND ROOF EDGE/SLOPE EXSTING ROOF EDGE/SLOPE AREA OF EXISTING ROOFING TO REMOVE NEW SHINGLES STANDING SEAM ROOFING DN DN DN PLEASE RECYCLE ROOF PLAN SCALE: 1/4" = 1'-0" @ 22x34 | 1/8" = 1'-0" @ 11x17 01 DEMO ROOF PLAN SCALE: 1/4" = 1'-0" @ 22x34 | 1/8" = 1'-0" @ 11x17 02 N REMOVE ROOFING, ROOF DECK AND ROOF FRAMING IN THIS AREA, REF STUCTURAL. REMOVE ROOFING FOR TIE-IN, UNDERLAYMENT TO REMAIN M P 1 4 : 4 1 : 3 0 2 0 2 / 6 2 / . 2 G W D 3 3 2 A - 3 0 S G N W A R D 0 I \ \ L E D O M E R L L A Y R - 3 0 9 1 \ : X I 5 1 0 2 S T C E T H C R A K R O Y Y E N N K C M © I ROOF PLAN DEMO NOTES 1. REMOVE SHINGLES 1'-0" BEYOND CUT LINE IN ROOF TO LAP SHINGLES. ROOF PLAN NOTES LAP SHINGLES INTO EXISTING ROOF SHINGLES TO REMAIN. DO NOT INSTALL FRAMING ON TOP OF ROOFING MATERIAL. ROOF UNDERLAYMENT: PROVIDE COMPLETE UNDERLAYMENT OF GRACE ICE & WATER SHIELD AT STANDING SEAM ROOFING. INSTALL SHINGLE STYLE WITH 8" VERTICAL OVERLAP MINIMUM, STRIP IN UNDERNEATH EXISTING BUILDING FELT MINIMUM 0'-8" VERTICALLY. PROVIDE #15 FELT AT NEW SHINGLED ROOFING AREAS, INSTALL SHINGLE STYLE UNDER EXISTING ROOFING FELT MINIMUM 8" VERTICALLY. 1. 2. 3. 3.1. 3.2. 1301 E. 7th Street Austin, TX 78702 ph: 512 476 0201 fx: 512 476 0216 www.mckinneyyork.com CONTACT: MICHELLE ROSSOMANDO GIST E R E D AR LL E R OSS O C H I T E R E H C I M S T 180 0 5 A T E FO E C T M A N D O SA X E T 01/21/2020 MICHELLE ROSSOMANDO 01/21/2020 STRUCTURAL ENGINEER: FORT STRUCTURES PH: 512-817-9264 CONTACT: SAM COVEY E C N E D I S E R L L A Y R - S N R A E K H E V A 3 0 8 3 2 5 7 8 7 S A X E T , I N T S U A # REVISION DATE CONSTRUCTION DOCUMENTS PROJECT NO. DATE 1903 01/21/2020 ROOF PLAN & DEMO PLAN A233 BOT OF MAIN RIDGE 120'-1" BOT OF FRONT RIDGE 118'-7" 2ND LEVEL 110'-2" CEILING 109'-3" 1ST LEVEL 100'-0" 2ND LEVEL 110'-2" CEILING 109'-3" 1ST LEVEL 100'-0" 2ND LEVEL 110'-2" CEILING 109'-3" 1ST LEVEL 100'-0" BOT OF MAIN RIDGE 120'-1" BOT OF FRONT RIDGE 118'-7" BOT OF MAIN RIDGE 120'-1" BOT OF FRONT RIDGE 118'-7" M P 2 5 : 4 1 : 3 0 2 0 2 / 6 2 / . 2 G W D 1 1 3 A - 3 0 S G N W A R D 0 I \ \ L E D O M E R L L A Y R - 3 0 9 1 \ : X I 5 1 0 2 S T C E T H C R A K R O Y Y E N N K C M © I EXISTING EXISTING NEW DORMER WITH DIVIDED LIGHT WINDOWS EXISTING NEW EXISTING NEW REPLACE MISSING DIVIDED WINDOW SCREEN, MATCH OTHER EXISTING SIMILAR SCREENS REPLACE SCREENS WITH 6 BY 6 DIVIDED WINDOW SCREENS REPLACE MISSING DIVIDED WINDOW SCREEN, MATCH OTHER EXISTING SIMILAR SCREENS 31 2" MAX PTD STEEL HANDRAIL BIKE RAMP WOOD DECK EXISTING NEW EXISTING NEW WEST ELEVATION SCALE: 1/4" = 1'-0" @ 22x34 | 1/8" = 1'-0" @ 11x17 04 REPLACE MISSING DIVIDED WINDOW SCREEN, MATCH OTHER EXISTING SIMILAR SCREENS NEW REPLACE MISSING DIVIDED WINDOW SCREENS ON THIS GROUP OF FOUR WINDOWS. MATCH OTHER EXISTING SIMILAR SCREENS PROVIDE DIVIDED WINDOW SCREENS TO MATCH SIMILAR SCREENS EXISTING NEW EXISTING LIMITS OF EXISTING CONSTRUCTION 4'-0" MIN FROM OPERABLE WINDOW TANKLESS WATER HEATER INSTALL PER MANUFACTURER'S INSTRUCTIONS AND PROVIDE CONCEALED SERVICE CONNECTIONS. REPLACE MISSING DIVIDED WINDOW SCREENS ON ALL WINDOWS IN THIS AREA NORTH ELEVATION SCALE: 1/4" = 1'-0" @ 22x34 | 1/8" = 1'-0" @ 11x17 01 BOT OF MAIN RIDGE 120'-1" BOT OF FRONT RIDGE 118'-7" 2ND LEVEL 110'-2" CEILING 109'-3" 1ST LEVEL 100'-0" 1301 E. 7th Street Austin, TX 78702 ph: 512 476 0201 fx: 512 476 0216 www.mckinneyyork.com CONTACT: MICHELLE ROSSOMANDO GIST E R E D AR LL E R OSS O C H I T E R E H C I M S T 180 0 5 A T E FO E C T M A N D O SA X E T 01/21/2020 MICHELLE ROSSOMANDO 01/21/2020 STRUCTURAL ENGINEER: FORT STRUCTURES PH: 512-817-9264 CONTACT: SAM COVEY E C N E D I S E R L L A Y R - S N R A E K H E V A 3 0 8 3 2 5 7 8 7 S A X E T , I N T S U A PLEASE RECYCLE # REVISION DATE CONSTRUCTION DOCUMENTS PROJECT NO. DATE 1903 01/21/2020 EXTERIOR ELEVATIONS A311 PROVIDE DIVIDED WINDOW SCREENS TO MATCH SIMILAR SCREENS EAST ELEVATION SCALE: 1/4" = 1'-0" @ 22x34 | 1/8" = 1'-0" @ 11x17 03 BOT OF MAIN RIDGE 120'-1" BOT OF FRONT RIDGE 118'-7" BIKE RAMP WOOD DECK SOUTH ELEVATION SCALE: 1/4" = 1'-0" @ 22x34 | 1/8" = 1'-0" @ 11x17 02 BOT OF MAIN RIDGE 120'-1" BOT OF FRONT RIDGE 118'-7" 2ND LEVEL 110'-2" CEILING 109'-3" 1ST LEVEL 100'-0" 2ND LEVEL 110'-2" CEILING 109'-3" 1ST LEVEL 100'-0" WINDOW AND DOOR NOTES 1. 2. 3. DIMENSIONS SHOWN ARE TO ROUGH OPENING, UIO FOR DOOR SWING DIRECTION, REFERENCE PLANS PROVIDE SCREENS AT ALL OPERABLE WINDOWS ELEMENT FINISH SCHEDULE NOTES 1. FIELD FINISH ITEMS IN ELEMENT FINISH SCHEDULE UNLESS INDICATED OTHERWISE. 1301 E. 7th Street Austin, TX 78702 ph: 512 476 0201 fx: 512 476 0216 www.mckinneyyork.com CONTACT: MICHELLE ROSSOMANDO GIST E R E D AR LL E R OSS O C H I T E R E H C I M S T 180 0 5 A T E FO E C T M A N D O SA X E T 01/21/2020 MICHELLE ROSSOMANDO 01/21/2020 STRUCTURAL ENGINEER: FORT STRUCTURES PH: 512-817-9264 CONTACT: SAM COVEY E C N E D I S E R L L A Y R - S N R A E K H E V A 3 0 8 3 2 5 7 8 7 S A X E T , I N T S U A ROOM FINISH SCHEDULE E M A N FRONT PORCH LIVING ROOM DINING ROOM HALLWAY HALLWAY CLOSET MAX'S ROOM BATHROOM 1 BATHROOM CLOSET BATHROOM 2 KITCHEN LILY'S ROOM MAIN BEDROOM LAUNDRY/MUD ROOM LOFT BATHROOM 3 BALCONY STORAGE STORAGE HVAC EXIST WD EXIST WD PTD WB PTD WB REPAINT T.M.E. REPAINT T.M.E. H T R O N L L A W EXIST EXIST EXIST EXIST PTD WB PAINT EXIST PTD WB EXIST EXIST EXIST EXIST EXIST PTD WB L L A W T S A E EXIST EXIST EXIST EXIST EXIST PTD WB EXIST EXIST EXIST EXIST EXIST PTD WB SURFACES R O O L F EXIST CONC EXIST WD EXIST WD EXIST WD EXIST WD EXIST WD EXIST WD EXIST WD EXIST WD EXIST WD EXIST WD EXIST WD WD T&G TBD TBD PLYWOOD PLYWOOD PLYWOOD E S A B - EXIST WD EXIST WD WD EXIST WD EXIST WD EXIST WD EXIST WD EXIST WD EXIST WD EXIST WD EXIST WD WD WD WD WD WD - T S E W L L A W - EXIST EXIST EXIST PTD WB PAINT EXIST PTD WB EXIST EXIST EXIST EXIST EXIST PTD WB G N I L I E C REPAINT T.M.E. REPAINT T.M.E. EXIST REPAINT T.M.E. PAINT REPAINT T.M.E. REPAINT T.M.E. REPAINT T.M.E. REPAINT T.M.E. REPAINT T.M.E. REPAINT T.M.E. REPAINT T.M.E. PTD WB PTD WB ELEMENTS S N I - T L I U B & S T E N B A C I T R E T N U O C S E C A F R U S & S P O K R A M E R - - - - - - - - - - - - - - - - PT - PT - - - - - - - - - - - - - - - - TBD TBD TBD REF INT ELEV PT WD V-GROOVE PT WB PT WB - REF INT ELEV PT WD V-GROOVE PT WB PT WB - REF INT ELEV PT WD V-GROOVE PT WB PT WB - REF INT ELEV PT WD V-GROOVE PT WB PT WB - PTD WB PT WD V-GROOVE TBD TBD - REF INT ELEV FOR EXTENT OF ACCENT TILE REF INT ELEV FOR EXTENT OF ACCENT TILE REF INT ELEV FOR EXTENT OF BACKSPLASH TILE H T U O S L L A W - EXIST EXIST EXIST EXIST PTD WB EXIST EXIST EXIST EXIST EXIST PTD WB 1X4 PAINT PAINT PAINT PAINT PAINT CLEAR FINISH WD BASE WD BASE TILE TILE TILE EXIST FLOORING NEW FLOORING NEW FLOORING LAUNDRY LEV 2 RR LEV 2 DESK LOW VOC LOW VOC LOW VOC LOW VOC LOW VOC POLYURETHANE T.M.E. T.M.E. MOSAIC SUBWAY EDGING T&G LONGLEAF PINE T&G YELLOW PINE SHEET FLOORING SOLID SURFACE SOLID SURFACE SOLID SURFACE - - - - - - - - - - - - - - - - - - - T.M.E. T.M.E. T.M.E. TBD TBD TBD 3X6 1X6 TME TBD TBD TBD TBD TBD ITEM TRIM DOORS PANELING TREADS AND RISERS STAIR POST PICKETS HANDRAIL INTERIOR PANELING PANELED CEILING RAILINGS BENCH BENCH MILLWORK LOCATION DOORS - STAIR STAIR STAIR STAIR STAIR LEVEL 2 BALCONY LEVEL 2 BALCONY LEVEL 2 BALCONY LAUNDRY/MUD ROOM BACK PORCH MUD ROOM ROOM R E B M U N 00 01 02 03 03A 04 05 05A 06 07 08 09 10 20 21 22 23 24 25 PT-1 PT-2 PT-3 PT-4 PT-5 V-1 B-1 B-2 T-1 T-2 T-3 F-1 F-2 F-3 CT-1 CT-2 CT-3 M P 2 2 : 5 1 : 3 0 2 0 2 / 6 2 / . 2 G W D 1 1 8 A - 3 0 S G N W A R D 0 I \ \ L E D O M E R L L A Y R - 3 0 9 1 \ : X I 5 1 0 2 S T C E T H C R A K R O Y Y E N N K C M © I ITEM LAVATORY SHOWER HEAD SHOWER TRIM KIT SHOWER FLOOR SHOWER WALLS TOILET MIRROR ITEM LAUNDRY SINK WASHER DRYER STEPLADDER EXTERIOR BIKE RACK CLOTHESLINE HAMPER FINISH INDEX DOOR SCHEDULE HARDWARE COORDINATION MARK ITEM DESCRIPTION MANUFACTURER SERIES COLOR/FINISH SIZE CONTACT REMARK DOOR SIZE DOOR DETAILS HARDWARE ELEMENT FINISH SCHEDULE DESCRIPTION FACTORY FINISH FIELD FINISH AS SCHEDULED AS SCHEDULED AS SCHEDULED AS SCHEDULED AS SCHEDULED S L E N A P F O R E B M U N 1 1 1 1 1 1 2 2 1 1 2 2 2 ) I ( S H T D W L E N A P 2'-8" 2'-0" 2'-8" 3-0" 3'-0" 2'-4" 2'-1" 3'-0" 3'-0" 2'-1" 2'-1" 2'-1" 2'-1" R E B M U N R O O D 100 101 102 103 200 201 202 203 204 205 206 207 208 1 T H G E H I 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-6" 6'-2" 6'-2" 3'-11" 3'-11" 3'-11" 3'-11" S S E N K C H T I 1-3/4" 1-3/4" 1-3/4" 1-3/4" 1-3/4" 1-3/4" 1-3/4" 1-3/4" 1-3/4" 1-3/4" 1-3/4" 1-3/4" 1-3/4" E P Y T A A A B D C C E C C C C C I L A R E T A M WD WD WD TBD TBD WD WD WD WD WD WD WD WD I H S N F I PT PT PT PT PT PT PT PT PT PT PT PT PT S S A L G - - - - - - - - - - - SINGLE PANE GLASS, T.M.E. TEMPERED, INSUL GLASS D A E H B M A J L L S I K R A M E R - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - SALVAGED PANEL, CUSTOM POCKET DOOR TRACK: HAFELE HAWA JUNIOR B OR SIMILAR SALVAGED DOOR & JAMB SALVAGED DOOR & JAMB EXTERIOR EXTERIOR UPSTAIRS RESTROOM SLIDING DOOR IN HALL HVAC CLOSET ACCESS POCKET DOOR IN ATTIC ROOM SLIDING DOOR IN ATTIC ROOM SLIDING DOOR IN ATTIC ROOM SLIDING DOOR IN ATTIC ROOM SLIDING DOOR IN ATTIC ROOM SALVAGE EXISTING, MAKE INOPERABLE REUSE EXISTING REUSE EXISTING TBD TBD TO MATCH EXISTING DOWNSTAIRS RECESSED METAL PULLS TBD RECESSED METAL PULLS RECESSED METAL PULLS RECESSED METAL PULLS RECESSED METAL PULLS RECESSED METAL PULLS T E S E R A W D R A H 1 P O T S - PT T.M.E. PT T.M.E. PT CLEAR PT PT CLEAR PT PT PT CLEAR WATERPROOF COATING TBD TBD FINISH FLOOR 0'-0" A SALVAGED B SOLID WOOD EXTERIOR DOOR D E L U D E H C S S A D E L U D E H C S S A D E L U D E H C S S A C RAIL AND PANEL DOOR TO MATCH EXISTING INTERIOR DOORS D FULL LIGHT EXTERIOR DOOR E SOLID CORE FLAT SLAB DOOR D E L U D E H C S S A 6'-2" " 1 - ' 3 " 5 - ' 2 " 4 - ' 2 NON-OPERABLE WINDOW 11'-6" FABRICATE LOWER WINDOW SASH TO MATCH SALVAGED ORIGINAL ARCHED WINDOW SASHES K R A M E R D E L U D E H C S S A ACCESSORY & FIXTURE SCHEDULE - RESTROOM 3 MANUFACTURER MODEL FINISH REMARK R 2 4 ' - 4 " , V . I . F . CL EQ CL EQ CL EQ CL EQ CL EQ CL DOOR TYPES SCALE: 1/4" = 1'-0" | 1/8" = 1'-0" @ 11x17 02 PLEASE RECYCLE 1 2/27/2020 ACCESSORY & FIXTURE SCHEDULE - LAUNDRY/MUDROOM MANUFACTURER MODEL FINISH REMARK XTEND & CLIMB LIGHT SLIMLINE 3 STEP LADDER SL3H MFR ALUMINUM BIKE STORAGE MONKEY BARS BIKE STORAGE RACK - MFR PTD OWNER SUPPLIED OWNER SUPPLIED CONFIRM 17. 2" W X 2. 5"D X 51. 5" H WHEN FOLDED, REF INT ELEVS. PROVIDES STORAGE FOR 5-6 BIKES, DEPENDING ON HANDLEBARS FINISH FLOOR 0'-0" " 5 - ' 6 1 WINDOW SCREEN WINDOW SCREEN " 7 - ' 5 1 . O R . " 1 1 - ' 3 . F . I . V . O R . " 0 1 - ' 5 . F . I . V " 0 - ' 8 2'-4" R.O. V.I.F. 3'-0" R.O. V.I.F. # REVISION DATE CONSTRUCTION DOCUMENTS PROJECT NO. DATE 1903 01/21/2020 WINDOW AND DOOR TYPES SCHEDULES A811 WINDOW TYPES SCALE: 1/4" = 1'-0" | 1/8" = 1'-0" @ 11x17 01 W-1 W-2 W-3 W-4