REGULAR MEETING OF THE HISTORIC LANDMARK COMMISSION ARCHITECTURAL REVIEW COMMITTEE WEDNESDAY, OCTOBER 14, 2026, AT 4:00 P.M. PERMITTING AND DEVELOPMENT CENTER, CONFERENCE ROOM 1401 6310 WILHELMINA DELCO DR AUSTIN, TEXAS Some members of the Historic Landmark Commission may be participating by videoconference. Public comment will be allowed in-person or remotely via telephone. Speakers may only register to speak once either in-person or remotely and will be allowed up to three minutes to provide their comments. Registration no later than noon the day before the meeting is required for remote participation by telephone. To register to speak remotely, please use the QR code or link at the end of this document. For questions, please email preservation@austintexas.gov. KEVIN KOCH JAIME ALVAREZ HARMONY GROGAN CURRENT COMMISSIONERS AGENDA CALL TO ORDER PUBLIC COMMUNICATION: GENERAL The first 10 speakers signed up prior to the meeting being called to order are allowed three minutes to speak on items not posted to the agenda. APPROVAL OF MINUTES 1. Approve the minutes of the Architectural Review Committee regular meeting on September 10, 2026. DISCUSSION ITEMS 2. 3. 4. 5. 6. 7. 8. 9. PR-2026-018321; HR-2026-112231; C14H-1982-0001-f – 916 Congress Ave. Larmour Block (F) Council District 9 Proposal: Reconstruct and construct a performance venue behind the existing façade. Applicant: Patrick Georgiou HR-2026-106327 – 2410 E. Martin Luther King Jr. Blvd. Rogers-Washington-Holy Cross Local Historic District Council District 1 Proposal: Construct two new residences. Applicant: Felicia Foster HR-2026-104982 – 4309 Avenue D Hyde Park Local Historic District Council District 9 Proposal: Remodel a contributing building and convert the garage into an additional housing unit. Applicant: Susan Pryor PR-2026-079349 – 706 E. Monroe St. Travis Heights-Fairview Park National Register Historic District Council District 9 Proposal: Demolish a contributing building. Applicant: Hannah Ma HR-2026-118672 – 211 Academy Dr. Travis Heights-Fairview Park National Register Historic District Council District 9 Proposal: Demolish a contributing building. Applicant: Paul Michals PR-2026-113688 – 800 W. 34th St. Council District 9 Proposal: Demolish a ca. 1975 office building. Applicant: AAR Inc. PR-2026-113706 – 801 W. 34th St. Council District 9 Proposal: Demolish a ca. 1968 office building and skybridge. Applicant: AAR Inc. 4113 Guadalupe St. Council District 9 Proposal: Rehabilitate an individual National Register property. Applicant: Kristin Schieffer ADJOURNMENT The City of Austin is committed to compliance with the Americans with Disabilities Act. Reasonable modifications and equal access to communications will be provided upon request. For assistance, please …
REGULAR MEETING OF THE HISTORIC LANDMARK COMMISSION ARCHITECTURAL REVIEW COMMITTEE THURSDAY, SEPTEMBER 10, 2026, AT 4:00 P.M. PERMITTING AND DEVELOPMENT CENTER, CONFERENCE ROOM 1401 6310 WILHELMINA DELCO DR AUSTIN, TEXAS Some members of the Historic Landmark Commission may be participating by videoconference. Public comment will be allowed in-person or remotely via telephone. Speakers may only register to speak once either in-person or remotely and will be allowed up to three minutes to provide their comments. Registration no later than noon the day before the meeting is required for remote participation by telephone. To register to speak remotely, please use the QR code or link at the end of this document. For questions, please email preservation@austintexas.gov. X KEVIN KOCH AB JAIME ALVAREZ X HARMONY GROGAN CURRENT COMMISSIONERS DRAFT MINUTES CALL TO ORDER: 4:04PM PUBLIC COMMUNICATION: GENERAL The first 10 speakers signed up prior to the meeting being called to order are allowed three minutes to speak on items not posted to the agenda. APPROVAL OF MINUTES 1. Approve the minutes of the Architectural Review Committee regular meeting on August 12, 2026. MOTION: Approve the August 12, 2026 meeting minutes. Motion by Commissioner Grogan. Commissioner Koch seconded the motion. Vote 2-0. The motion passed. DISCUSSION ITEMS 2. 3. 4. 5. 6. 608 Blanco St. Castle Hill Local Historic District Council District 9 Proposal: Raise the porch and rebuild the railing, install planters, install an ADA lift, and reinstall decorative trim of a contributing building. Applicant: Scott Magic The applicant presented their proposal. The committee provided feedback. 704 Baylor St. Castle Hill Local Historic District Council District 9 Proposal: Construct a second-story addition on a contributing building. Applicant: Tisha Ritta The applicant did not attend. C14H-1976-0024 – 1006 Congress Ave. Lundberg Bakery Council District 9 Proposal: Rehabilitate and construct an addition to a landmark. Applicant: Sue Hagerty The applicant presented their proposal. The committee provided feedback. C14H-2020-0087 – 3908 Avenue B Baker School Council District 9 Proposal: Place three 40ft shipping containers on the property with no alterations to the landmarked building. Applicant: Brittany Garcia The applicant presented their proposal. The committee provided feedback. C14H-2015-0001 – 908 E. 11th St. Dedrick-Hamilton House Council District 1 Proposal: Install accessibility improvements and expand porch access at a landmarked building. Applicant: DJ Scales The applicant presented their proposal. The committee provided feedback. 7. C14H-2018-0010 – 3952 Berkman Dr. Mueller Air Control Tower Council District 9 Proposal: …
BLOCK OUT PHASE BLOCK OUT PHASE COMPLETE. CLIENT APPROVES CONTINUING INTO PRELIMINARY PHASE. ___________________________________________________________________________________________________ SIGNATURE DATE ___________________________________________________________________________________________________ SIGNATURE DATE PRELIMINARY PHASE PRELIMINARY PHASE COMPLETE. CLIENT APPROVES CONTINUING INTO FINAL PHASE. ___________________________________________________________________________________________________ SIGNATURE DATE APPROVED BY CLIENT 06.10.26 APPROVED BY CLIENT 07.13.26 ___________________________________________________________________________________________________ SIGNATURE DATE FINAL PHASE FINAL PHASE COMPLETE. CLIENT APPROVES RELEASING OF BID SET. ___________________________________________________________________________________________________ SIGNATURE DATE ___________________________________________________________________________________________________ SIGNATURE DATE LOT SIZE: IMP. COVER: (45%) FAR: (55%) 5996 SF 44.9% 44.86% SLAB AREA CHART NAME BLDG 1 SLAB BLDG 2 SLAB TOTAL SLAB AREA: AREA 813.00 SF 766.50 SF 1,579.50 SF IMPERVIOUS COVER AREA CHART NAME BLDG 1 SLAB BLDG 1 AC PAD BLDG 2 SLAB BLDG 2 AC PAD DRIVEWAY PARKING PAD IMPERVIOUS COVER TOTAL: AREA 813.00 SF 9.00 SF 766.50 SF 9.00 SF 902.55 SF 192.71 SF 2,692.76 SF These drawings and the information herein contained are the sole intellectual property of Barron Custom Design, LLC and may not be reproduced in any manner without the company ’s written consent. These drawings constitute what is normally considered within the construction industry as a “builder set” in as they are intended to convey the design intent only. The implementation of the plans requires a general contractor/subcontractor thoroughly knowledgeable with applicable building codes and methods of construction. The plans are intended to provide basic information regarding site work, electrical, mechanical, plumbing, and other trades to substantially complete construction of the structure. Exact material specifications and selections from agreed “allowances ” are to be confirmed with the owner prior to ordering and/or installation. If provided, contractor/subcontractor to review Owner “image” photos and details and confirm all related details and finishes prior to commencement of construction. Construction means, methods, and materials are solely the jurisdiction of the contractor/subcontractor and are not described in these plans. Exact detailing, structural, mechanical, electrical, waterproofing and flashings are to be determined by the contractor/subcontractor except as noted or described within these drawings. In all cases, the most stringent requirements of all applicable federal, state, county, and local city building, mechanical, electrical, plumbing, and fire codes, laws, ordinances, and regulations must be met. If the contractor/subcontractor or any subcontractor performs any work in conflict with the above mentioned laws, rules, codes, ordinances, and regulations then the contractor/subcontractor in violation shall bear all costs of repair arising out of non-conforming work. All such codes, ordinances, deed restrictions and regulations take precedence over any part of these drawings …
Austin Historic Landmark Commission Architectural Review Committee HR-2026-118672 211 ACADEMY DR Property: LOT 1 BLK 68-71 ODIORNE RESUB OF FAIRVIEW PARK Lot sizes are taken from Traviscad.org South side of 200 block of Academy Dr 211 Academy looking West Lack of building separation between 211 and 209 Academy Better image showing the lack of separation
HLC Review Addendum 07 Oct 2026 4309 Avenue D Item HR-2026-104982 1.2 The concrete pad as front porch is structurally unsound and must be replaced. The steps outside the primary entry door is not allowed by today’s building code. Required Egress Doors: Must have a flat landing on each side that is at least as wide as the door and extends a minimum of 36 inches in the direction of travel. The floor or landing cannot be more than 1.5 inches lower than the top of the threshold for primary egress doors The elevated porch fits the neighborhood and satisfies IRC Bldg Code 2024 1.2 The second front door is not original to the 1912 home and was added around the time of the Great Depression in 1929. While it is old, it is not original. It enters directly into bedroom and is not in character with the 1912 house Queen Anne-esque house. Our rehabilitation of this home ( back to single family) includes restoring the original transom in the entry foyer over the original front door. See picture…. The secondary door is a five panel interior non-weather rated door taken from another bedroom. Probably done when Clara Stubbs divided the house for daughter Clara to live there ? There was never a transom over the secondary narrower door. 1.2 The current “temporary” front porch posts are not original. Evidence in the slab indicate there may have originally been paired posts – possibly lathe turned like other homes of the 1910’s ?? The columns shown in the proposed front elevation are HBG fiberglass structural columns without direct historical reference to any period. These round columns invoke the past but are also very common in new homes today. 3.1 Restoring windows as possible instead of replacement sounds great and will be our course of action if feasible. Front windows ( as seen from street ) seem easily restorable. However, the north side ( unseen from street ) seems harder…… An updated window schedule indicating restored and new windows is attached.
September 15, 2026 To: Julie Briggs EFP 4113 Guadalupe LLC Aus&n, Texas julieermisbriggs@yahoo.com cc: Kris&n Schieffer, RA, LEED AP – ALIGN Aus&n Architects kris&n@alignaus&narchitects.com From: Nicholas Rohr, P.E., S.E. Managing Principal – Anderson Rohr Engineers, LLC Phone: 720-687-3730 Email: rohr@andersonrohr.com Structural Assessment Le(cid:23)er – Exis(cid:28)ng Building Project: 4113 Guadalupe Renova&on (ARE Project No. 26-060-ALA) Site Address: 4113 Guadalupe St, Aus&n, TX 78751 Site Visit Date: September 10, 2026 ARE A(cid:25)endee: Nicholas Rohr, P.E., S.E. Reference: ALIGN Aus&n Architects Preliminary Demoli&on Exhibit dated August 14, 2026 Introduc(cid:28)on On September 10, 2026, Nicholas Rohr, P.E., S.E. of Anderson Rohr Engineers, LLC (ARE) visited 4113 Guadalupe St to perform a visual structural assessment of the exis&ng building in support of the proposed renova&on. The General Contractor had removed finishes at the loca&ons shown on the ALIGN Aus&n Architects Preliminary Demoli&on Exhibit dated August 14, 2026, and the exposed structure at those loca&ons was observed and measured. The findings below are based on the condi&ons that were accessible on the date of the visit. Condi&ons that remained concealed by finishes, flooring, or the roof deck were not observable and are not included in this assessment except where noted as an&cipated. Only visual observa&ons were made; no material tes&ng, destruc&ve inves&ga&on, or geotechnical inves&ga&on was performed. Building Descrip(cid:28)on The exis&ng building is a single-story wood-framed commercial retail building with a brick front facade at Guadalupe Street. The building is approximately 50 feet deep by 25 feet wide, with adjacent buildings on each side. The exis&ng structure appears to be on an independent founda&on, separate from the adjacent buildings. The gap between the exterior north wall and the adjacent building to the north is approximately 21 inches. A masonry wall of the adjacent building is located along the south side. Anderson Rohr Engineers, LLC – Structural Assessment Le(cid:25)er P a g e | 1 The primary structure consists of the following, as observed: • Founda&on: Timber piles embedded in the ground suppor&ng a 4x6 pressure-treated &mber beam at the perimeter. No concrete support was found at the &mber piles. The spacing of the piles could not be verified. • Floor: 2x6 floor joists at 24 inches on center bearing on the 4x6 &mber beam, with wood decking over. Joist spans could not be verified. • Walls: Load-bearing walls of 2x4 studs at 24 inches on center running the length of the building. The exterior finish on …