HISTORIC LANDMARK COMMISSION ARCHITECTURAL REVIEW COMMITTEE Wednesday, April 9, 2025 – 4:00PM Permitting and Development Center Conference Room 1401 6310 Wilhelmina Delco Dr Austin, TX 78752 Some members of the committee may be participating by videoconference Public comment will be allowed in-person or remotely via telephone. Speakers may only register to speak on an item once either in-person or remotely and will be allowed up to three minutes to provide their comments. Registration no later than noon the day before the meeting is required for remote participation by telephone. To register to speak remotely, use the QR code on this agenda. For questions, email preservation@austintexas.gov or call Sam Fahnestock at (512) 974- 3393. COMMITTEE MEMBERS: Kevin Koch Jaime Alvarez Harmony Grogan AGENDA CALL TO ORDER PUBLIC COMMUNICATION: GENERAL The first ten (10) speakers who register to speak no later than noon the day before the meeting will be allowed a three-minute allotment to address their concerns regarding items not posted on the agenda. DISCUSSION ITEMS 1. 2. 3710 Cedar St. Confederate Woman’s Home Council District 9 Proposal: Preserve existing buildings, addition on historic lots, new construction on non-historic lots. Applicant: Abby Tatkow 6706 Bluff Springs Rd. Horton-Duval House Council District 2 Proposal: Hazardous conditions abatement. 3. 4. 5. 6. 7. 8. 9. Applicant: Code Department 604 Brazos St. The Driskill Hotel Council District 9 Proposal: Wood trim repair at exterior windows. Applicant: Marcos Crane 4208 Avenue F. Hyde Park Council District 9 Proposal: Fix disrepair, construct addition to the side and rear second story. Applicant: Robert Howard 4411 Avenue B. Hyde Park Council District 9 Proposal: Rear addition. Applicant: Robert Howard 1200 Windsor Rd. West Line National Register Historic District Council District 9 Proposal: Rehabilitate historic house and construct detached housing structures on site. Applicant: Jonathan Tate 1107 Eason St. West Line National Register Historic District Council District 9 Proposal: New construction. Applicant: Trey Farmer 4812 Mount Bonnell Rd. Dry Creek Café Council District 10 Proposal: Renovate accessory structure; structural reinforcement; new windows. Applicant: Victoria Haase 2315 Lake Austin Blvd. Deep Eddy Cabaret Council District 10 Heritage Grant Project Proposal: Restore roof; repair wood elements and gutters; repair and repoint limestone and stucco; restore doors and windows. Applicant: Will Bridges 10. 507 E 10th St. German Free School Council District 10 Heritage Grant Project Proposal: Repair front wall. Applicant: Christopher Markley 11. 12. 905 Congress Ave. The Mutual Building Council …
HISTORIC LANDMARK COMMISSION ARCHITECTURAL REVIEW COMMITTEE Wednesday, April 9, 2025 – 4:00PM Permitting and Development Center Conference Room 1401 6310 Wilhelmina Delco Dr Austin, TX 78752 Some members of the committee may be participating by videoconference Public comment will be allowed in-person or remotely via telephone. Speakers may only register to speak on an item once either in-person or remotely and will be allowed up to three minutes to provide their comments. Registration no later than noon the day before the meeting is required for remote participation by telephone. To register to speak remotely, email preservation@austintexas.gov or call Sam Fahnestock at (512) 974-3393. COMMITTEE MEMBERS: Kevin Koch Jaime Alvarez Harmony Grogan AGENDA ADDENDUM CALL TO ORDER DISCUSSION ITEMS 13. ADJOURNMENT PUBLIC COMMUNICATION: GENERAL The first ten (10) speakers who register to speak no later than noon the day before the meeting will be allowed a three-minute allotment to address their concerns regarding items not posted on the agenda. 708 Highland Ave. Smoot-Terrace Park Local Historic District Council District 9 Proposal: Replace wooden porch; replace metal roof with shingle; add dormer; repair or replace rotted wood elements; replace rear deck; paint exterior. Applicant: Tere O’Connell The City of Austin is committed to compliance with the American with Disabilities Act. Reasonable modifications and equal access to communications will be provided upon request. Meeting locations are planned with wheelchair access. If requiring Sign Language Interpreters or alternative formats, please give notice at least 2 days (48 hours) before the meeting date. Please call the Historic Preservation Office at 512-974-3393 for additional information; TTY users route through Relay Texas at 711. For more information on the Historic Landmark Commission, please contact Sam Fahnestock, Planner II, at 512-974-3393; Kalan Contreras, Historic Preservation Officer, at 512-974-2727. ,£, First Floor () OD Coffee Shop South Elevator;; City of Austin Permitting and Development Center ' . Event Center Trahng Courtyard Employee Entrance lNo,-k:,t;;.tio,os 110-8.01 · 1108.16 Dr.;wing not toswle, repr...sentatioo purposes only. Elevators Employee Break Room Restrnoms Parking Garage l 6.25.20
BUILDING ONE - ELEVATIONS WAVERLY Austin, Texas THREE BAR ARCHITECTURE, INC. BUILDING TWO - ELEVATIONS WAVERLY Austin, Texas THREE BAR ARCHITECTURE, INC. BUILDING TWO - ELEVATIONS WAVERLY Austin, Texas THREE BAR ARCHITECTURE, INC.
708 HIGHLAND AVE PROJECT INFORMATION ARCHITECT STRUCTURAL ENGINEER LEGAL DESCRIPTION: LOT 5, BLOCK B OLT 3 DIV Z TERRACE PARK ZONING: SF-3-HD-NP YEAR CONSTRUCTED: 1922 OCCUPANCY: R-1 CONSTRUCTION TYPE: V-B O'CONNELL ARCHITECTURE, LLC TERE O'CONNELL, AIA 3908 AVENUE B, SUITE 309 AUSTIN, TEXAS 78751 512.751.1374 ARCH CONSULTING ENGINEERS, PLLC JUSTIN BILLODEAU, P.E. 2579 WESTERN TRAILS BLVD., SUITE 230 AUSTIN, TEXAS 78745 512.328.5353 GENERAL NOTES SCOPE OF WORK SHEET LIST 1. 2. 3. 4. 5. 6. 7. 8. All work shall be performed in a professional matter, and in accordance with the International Residential Code, 2021, related trade codes, and applicable local codes, ordinances and laws. Base drawings used in these documents may contain small dimensional discrepancies. Contractor shall verity critical dimensions before beginning work. Do not scale drawings. Ask Architect for needed dimensions if not provided. This property is a contributing building in the Smoot-Terrace Park Historic District. Historic designation of this building requires the Contractor and his subcontractors to exercise special caution in executing the work to prevent unnecessary damage to historic features, conditions, or materials. Contractor shall inform all subcontractors and workmen of these requirements. The Contractor shall thoroughly example and familiarize himself with the requirements of the Contract Documents. Any conflicts shall be brought to the Architect's attention for resolution prior to the work being installed. Perform all work in a safe and conscientious manner to prevent injuries and damage to the building and workers. Contractor shall maintain OSHA Standards for job safety and worker protection, and comply with applicable state and local government requirements. Building permitting will be coordinated by the Owner and Architect prior to construction. Contractor is responsible for all trade permits, inspections, and compliance requirements. Maintain the building and site in a safe, clean and orderly condition. The Contractor shall visit the site of the proposed work and full acquaint himself with the existing conditions regarding site access, staging, parking limitations, security, and other aspects of constructibility. 9. The Contractor shall coordinate work between all trades in this contract to ensure a smooth and timely workflow. 10. All work to be warranted for one year from the date of Substantial Completion unless otherwise noted. SYMBOL LEGEND FFE 0" FFE OR GRADE ELEVATION D-01 DOOR NUMBER 10101 WINDOW NUMBER CENTERLINE EXTERIOR ELEVATION SECTION PLAN/ELEVATION DETAIL 1 A-211 1 A-311 1 A-211 A-000 A-100 A-101 A-111 A-112 A-120 A-121 A-122 A-210 A-211 A-220 A-221 A-311 …
708 Highland 1922 Smoot/Terrace Park Local Historic District Robin Shepherd, Owner 5 Birds Dwellings, LLC Replace deck on west elevation West Elevation 708 Highland Avenue Repair or replace all damaged exterior wood in-kind North Elevation 708 Highland Avenue Clear all brush and debris To restore the exterior of house North Elevation 708 Highland Avenue Replace metal roof with composition shingles Restore historic windows South Elevation 708 Highland Avenue Wooden Stairs 708 Highland Avenue Site view 708 Highland Avenue Clear site of all overgrowth and correct drainage issues. Site condition 708 Highland Avenue New pier and beam foundation as required. Siding to be replaced to match original profile and detailing. New water table and cement skirt to be installed at perimeter. Foundation repair 708 Highland Avenue Historic windows and exterior trim 708 Highland Avenue Windows to be restored; Reconfigure existing windows in attic gable to match rough opening; new metal-clad wood window in new attic dormer. Repair or replace rotted wood at eaves, trim, siding to match original in dimension and detail Remove stone veneer and replace cement cladding to match historic as evidenced from underside of porch in crawlspace Attic with failing chimney, ill- fitting windows and haphazard ducting Remove unused chimney, reconfigure HVAC and finish attic for additional living space Attic space 708 Highland Avenue Enlarge and reorganize kitchen Restore hardwood floors; restore historic windows Interior spaces 708 Highland Avenue Google Map 708 Highland Avenue
4208 Avenue F, Austin, TX Vicinity Map PROJECT SCOPE The scope of work includes the extension of ground floor and construction of new garage and first floor, at 4208 Avenue F Austin including all associated site work, utilities, and landscaping. GNERAL NOTES Building Codes: All work shall comply with the 2021 International Residential Code (IRC), as adopted by the City of Austin. All construction shall comply with the City of Austin Land Development Code. Permits and Inspections: All necessary permits shall be obtained before the commencement of work. All inspections required by the City of Austin shall be scheduled and approved. Site Conditions: Verify all existing site conditions and dimensions before starting construction. Any discrepancies shall be reported to the architect/engineer for resolution. Utilities: Locate and protect all existing utilities. Contact utility companies before digging. All utility connections shall comply with the requirements of the respective utility providers. Demolition: Demolition of existing structures shall be done in accordance with local regulations. Ensure safe disposal of debris. Construction Standards: Follow standard construction practices and manufacturer ’s specifications. Materials shall be new and free from defects. Safety: Maintain a safe working environment. Follow OSHA regulations. Provide appropriate signage, barriers, and protection to ensure public safety. Specific Codes and Regulations Zoning Requirements: Verify compliance with local zoning laws, including setbacks, height restrictions, and lot coverage. Energy Code: Comply with the 2021 International Energy Conservation Code (IECC). Accessibility: Ensure accessibility as per the Texas Accessibility Standards (TAS) and the Americans with Disabilities Act (ADA), where applicable. Fire Safety: Install smoke detectors and carbon monoxide detectors as per IRC requirements. Comply with local fire department regulations. INDEX Sheet Name COVER SHEET CAMERA VIEW SITE PLAN PROPOSED ROOF PLAN EXISTING AND DEMOLISHED ROOF PLAN EXISTING AND DEMOLISHED 1ST FLOOR PLAN PROPOSED 1ST FLOOR PLAN PROPOSED 2ND FLOOR PLAN PROPOSED ELEVATION PROPOSED ELEVATION SECTION A & B DOOR WINDOW SCHEDULE WALL FRAMING LEVEL 1 PLAN WALL FRAMING LEVEL 2 PLAN Sheet # A001 A002 A003 A004 A005 A006 A007 A008 A009 A010 A011 A012 A013 A014 BUILDING DATA Parcel ID: Owner Name: Parcel Address: Parcel Address City: Parcel Address Zip Code: Parcel Use Code: Parcel Use Description: Block: Lot: Calculated Acres: Calculated Parcel Sq ft: Legal Description: 215803 STEWART PISECCO 4208 AVENUE F AUSTIN 78751-3721 01 1 FAM DWELLING 22 25-27 0.2163 9422 LOT 25-27 BLK 22 HYDE PARK ADDN NO 1 F e u n e …
4111 AVE B, Austin, TX Vicinity Map INDEX Sheet Name COVER SHEET SITE PLAN EXISTING DEMOLITION ROOF PLAN PROPOSED ROOF PLAN EXISTING AND DEMOLISHED ROOF PLAN PROPOSED 1ST FLOOR PLAN PROPOSED 2ND FLOOR PLAN PROPOSED ELEVATION NORTH & SOUTH PROPOSED ELEVATION EAST & WEST PROPOSED SECTION A & B PROPOSED SECTION C & D DOOR WINDOW SCHEDULE Sheet # A001 A002 A003 A004 A005 A006 A007 A008 A009 A010 A011 A012 BUILDING DATA Parcel ID: Owner Name: Parcel Address: Parcel Address City: Parcel Address Zip Code: Parcel Use Code: Parcel Use Description: Block: Lot: Calculated Acres: Calculated Parcel Sq ft: Legal Description: 0221050907 4111 AVENUE B, TX AUSTIN 78751 01 1 FAM DWELLING 17 5-6 0.1479 6,444.64 LOT 5-6 BLK 17 HYDE PARK ADDN NO 2 PROJECT SCOPE The scope of work includes the construction of new addition at 8004 Tisdale Drive, Austin including all associated site work, and utilities. GENERAL NOTES Building Codes: All work shall comply with the 2021 International Residential Code (IRC), as adopted by the City of Austin. All construction shall comply with the City of Austin Land Development Code. Permits and Inspections: All necessary permits shall be obtained before the commencement of work. All inspections required by the City of Austin shall be scheduled and approved. Site Conditions: Verify all existing site conditions and dimensions before starting construction. Any discrepancies shall be reported to the architect/engineer for resolution. Utilities: Locate and protect all existing utilities. Contact utility companies before digging. All utility connections shall comply with the requirements of the respective utility providers. Demolition: Demolition of existing structures shall be done in accordance with local regulations. Ensure safe disposal of debris. Construction Standards: Follow standard construction practices and manufacturer ’ s specifications. Materials shall be new and free from defects. Safety: Maintain a safe working environment. Follow OSHA regulations. Provide appropriate signage, barriers, and protection to ensure public safety. Specific Codes and Regulations Zoning Requirements: Verify compliance with local zoning laws, including setbacks, height restrictions, and lot coverage. Energy Code: Comply with the 2021 International Energy Conservation Code (IECC). Accessibility: Ensure accessibility as per the Texas Accessibility Standards (TAS) and the Americans with Disabilities Act (ADA), where applicable. Fire Safety: Install smoke detectors and carbon monoxide detectors as per IRC requirements. Comply with local fire department regulations. B e u n e v A 1 1 4 4 1 5 7 8 7 X T …
4208 Avenue F, Austin, TX Vicinity Map PROJECT SCOPE The scope of work includes the extension of the ground floor and a rear subordinate second story addition at 4208 Avenue F Austin including all associated site work. GNERAL NOTES Building Codes: All work shall comply with the 2021 International Residential Code (IRC), as adopted by the City of Austin. All construction shall comply with the City of Austin Land Development Code. Permits and Inspections: All necessary permits shall be obtained before the commencement of work. All inspections required by the City of Austin shall be scheduled and approved. Site Conditions: Verify all existing site conditions and dimensions before starting construction. Any discrepancies shall be reported to the architect/engineer for resolution. Utilities: Locate and protect all existing utilities. Contact utility companies before digging. All utility connections shall comply with the requirements of the respective utility providers. Demolition: Demolition of existing structures shall be done in accordance with local regulations. Ensure safe disposal of debris. Construction Standards: Follow standard construction practices and manufacturer ’s specifications. Materials shall be new and free from defects. Safety: Maintain a safe working environment. Follow OSHA regulations. Provide appropriate signage, barriers, and protection to ensure public safety. Specific Codes and Regulations Zoning Requirements: Verify compliance with local zoning laws, including setbacks, height restrictions, and lot coverage. Energy Code: Comply with the 2021 International Energy Conservation Code (IECC). Accessibility: Ensure accessibility as per the Texas Accessibility Standards (TAS) and the Americans with Disabilities Act (ADA), where applicable. Fire Safety: Install smoke detectors and carbon monoxide detectors as per IRC requirements. Comply with local fire department regulations. INDEX Sheet Name COVER SHEET CAMERA VIEW SITE PLAN PROPOSED ROOF PLAN EXISTING AND DEMOLISHED ROOF PLAN EXISTING AND DEMOLISHED 1ST FLOOR PLAN PROPOSED 1ST FLOOR PLAN PROPOSED 2ND FLOOR PLAN PROPOSED ELEVATION PROPOSED ELEVATION SECTION A & B DOOR WINDOW SCHEDULE Sheet # A001 A002 A003 A004 A005 A006 A007 A008 A009 A010 A011 A012 BUILDING DATA Parcel ID: Owner Name: Parcel Address: Parcel Address City: Parcel Address Zip Code: Parcel Use Code: Parcel Use Description: Block: Lot: Calculated Acres: Calculated Parcel Sq ft: Legal Description: HYDE PARK ADDN NO 1 215803 STEWART PISECCO 4208 AVENUE F AUSTIN 78751-3721 01 1 FAM DWELLING 22 25-27 0.2163 9422 LOT 25-27 BLK 22 F e u n e v A 8 0 2 4 1 5 7 8 7 X T , n …