HISTORIC LANDMARK COMMISSION ARCHITECTURAL REVIEW COMMITTEE Wednesday, March 12, 2025 – 4:00PM Permitting and Development Center Conference Room 1401 6310 Wilhelmina Delco Dr Austin, TX 78752 Some members of the committee may be participating by videoconference Public comment will be allowed in-person or remotely via telephone. Speakers may only register to speak on an item once either in-person or remotely and will be allowed up to three minutes to provide their comments. Registration no later than noon the day before the meeting is required for remote participation by telephone. To register to speak remotely, use the QR code on this agenda. For questions, email preservation@austintexas.gov or call Sam Fahnestock at (512) 974- 3393. COMMITTEE MEMBERS: Kevin Koch Jaime Alvarez Harmony Grogan AGENDA CALL TO ORDER PUBLIC COMMUNICATION: GENERAL The first ten (10) speakers who register to speak no later than noon the day before the meeting will be allowed a three-minute allotment to address their concerns regarding items not posted on the agenda. DISCUSSION ITEMS 1. 2. 6706 Bluff Springs Rd. Horton-Duval House Council District 2 Proposal: Hazardous conditions abatement. Applicant: Marlayna Wright 1301 Shoal Creek Blvd. House Park Council District 9 Proposal: Press box replacement. Applicant: AISD/Dave Anderson 1807 E Cesar Chavez St. Berner-Clark-Mercado House Council District 3 Proposal: Paint exterior; replace windows; replace columns, handrails, baluster; re-install sashes; add ramp on back patio. Applicant: David Rudick 1412 Preston Ave. Old West Austin National Register Historic District Council District 10 Proposal: Convert carport to garage, addition/remodel to front entry and rear. Applicant: Carissa Travis 3. 4. 5. 705 West Lynn St. West Line National Register Historic District Council District 9 Proposal: Total demolition. Applicant: DAR Construction/Scott Turner ADJOURNMENT The City of Austin is committed to compliance with the American with Disabilities Act. Reasonable modifications and equal access to communications will be provided upon request. Meeting locations are planned with wheelchair access. If requiring Sign Language Interpreters or alternative formats, please give notice at least 2 days (48 hours) before the meeting date. Please call the Historic Preservation Office at 512-974-3393 for additional information; TTY users route through Relay Texas at 711. For more information on the Historic Landmark Commission, please contact Sam Fahnestock, Planner II, at 512-974-3393; Kalan Contreras, Historic Preservation Officer, at 512-974-2727. REGISTER TO SPEAK https://forms.office.com/g/7ReQu6LfJD ,£, First Floor () OD Coffee Shop South Elevator;; City of Austin Permitting and Development Center ' . Event Center Trahng …
Austin Independent School District: House Park West Grandstand 1936 Baseball Stand and Diamond pre- date football stadium North Grandstand estimated 1947 West Grandstand & tennis courts 1938/39 Field House 1940 House Park Aerial 1937 House Park Aerial 1952 Baseball Stand and Diamond demoed and relocated 38/39 Austin Independent School District House Park Stadium North Grandstands demo unknown date Press Boxes estimated 60/70s Tennis Courts 1977 Baseball stands and diamond removed Parking added between 1973 & 1981 New Field House 2009 Field House Demolished 2009 House Park 1985 House Park 2011 Field Turfed 2008 Austin Recreation Center 1986 Austin Independent School District House Park Stadium House Park Stadium Improvements 3 New Freestanding Press Box East side ADA Ramps East & West Grandstand Concrete repair and repainting Easts & West Grandstand Concrete Repairs 4 • Concrete patch repairs of slabs, beams, walls, risers, and columns • Concrete repairs are only for the structural integrity of the grandstand ADA Access Ramp Improvements 5 • The existing ramps to the East and West grandstands currently do not meet ADA requirements • Existing ramps will be replaced with new ADA compliant ramps Existing East Grandstand Ramp Existing West Grandstand Ramp Grandstand Painting 6 • Existing painted surfaces of perimeter grandstand and walls to be repainted East Grandstand Ramp West Grandstand Ramp East & West Press Boxes 7 • AISD House Park Stadium Improvements includes removal of existing East and West Press Boxes • Press Boxes added to grandstands estimated 1960s (date to be verified) • Press boxes renovation 1986 • Existing press boxes do not have ADA access • Existing press boxes do not have emergency exit outside of the floodplain • Structural assessment completed 2016 identified multiple structural deficiencies to existing press boxes East Grandstand Ramp West Grandstand Ramp House Park Site 8 • The House Park site lies within a floodplain • The existing press boxes do not allow for egress out of the flood plain • The newly designed Freestanding Press Box allows for egress out of the floodplain East Grandstand Ramp West Grandstand Ramp Existing East Grandstand Press Box East Press Boxes 9 Conceptual Freestanding East Grandstand Press Box East Grandstand Ramp West Grandstand Ramp AISD: House Park East Press Box 1 0 • New press box honors the legacy of the House Park Stadium, while providing an opportunity for 21st century use and learning opportunities for staff and students • …
ENGINEER OR GEN. CONTRACTOR TO VERIFY DRAWINGS BEFORE CONSTRUCTION SITE PLAN NOTES: SOIL: *2,000 PSF ALLOWABLE (ASSUMED) TO BE AT TIME OF EXCAVATION. SHALLOW AND MODERATELY DEEP, WELL-DRAINED SOIL FORMED IN MATERIAL WEATHERED FORM BASALT THAT HAS A SMALL AMOUNT OF LOESS IN THE UPPER PART OF THE PROFILE. THE PERMEABILITY IS ESTIMATED TO BE GOOD. SITE SURVEY TO VERIFY PIN LOCATIONS PRIOR TO EXCAVATION. CONTRACTOR TO VERIFY LOCATION OF ALL EXISTING UTILITIES. ALL FINISH GRADES SHALL BE SMOOTH AND UNIFORM. EROSION CONTROL NOTES: 1. INSTALL SILT FENCE PRIOR TO ANY EXCAVATION OR CONSTRUCTION 2. MINIMIZE SITE DISTURBANCE BY TIGHT CONTROL OF EXCAVATION LIMITS. 3. ALL EXPOSED SOIL SHALL BE MULCHED WITH STRAW OR WOOD CHIPS TO MINIMIZE SOIL EROSION. NO SOIL SHALL BE LEFT IN AN EXPOSED CONDITION. IT IS RECOMMENDED THAT THE CONTRACTOR MAINTAIN A STOCK PILE OF THIS MATERIAL ON SITE FOR QUICK APPLICATION. GRADING NOTES: 1. CONTRACTOR TO VERIFY LOCATION OF ALL EXISTING UTILITIES. 2. ALL FINISH GRADES SHALL BE SMOOTH AND UNIFORM. 3. PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDING. NOTE PRIOR TO CONSTRUCTION: ALL DIMENSIONING MUST BE CHECKED AND VERIFIED BEFORE CONSTRUCTION MAY BEGIN. S 60 ° E 75' - 0" 50' - 0" 20' - 11 7/16" 10' OF LOT 6 10' - 0" " 8 / 5 1 - ' 2 2 POOL 320 SFT 6 T O L 7 T O L POOL PUMP 75.00' " 0 - ' 5 " 0 - ' 0 1 " 1 1 - ' 2 1 " 0 - ' 2 2 7 T O L 8 T O L 15' - 0" WOOD FENCE 5' PUE 10' REAR SETBACK EXISTING POOL RESHAPE AND MAKE SMALLER ALL STRUCTURE TO REMAIN IN PLACE SF-3-NP MIN SET BACK 25ft INTERIOR SIDE YARD 5ft REAR YARD 10ft IMP COVER 45% BUILDING COVER 40% ORDINANCE 20100923-103 LOT OF 4,000 SFT OR LESS IMP COVER 65% DN 5' - 0" 15' OF LOT 8 SEE ZONING REPORT 5' - 0" 5' SIDE SETBACK SEE ZONING REPORT WOOD FENCE " 6 - ' 7 3 1 ' 0 5 . 7 3 1 ACCESS FOR CONSTRUCTION DRIVEWAY PAD TO EXTEND TO SETBACK 5' SIDE SETBACK WOOD FENCE ACCESS FOR CONSTRUCTION ' 0 5 . 7 3 1 A/C 6' - 10 7/16" " 8 - ' 2 2 LOT 6 E ° 0 6 N 15' - 6 1/4" CONCRETE DRIVE …
1412 PRESTON HISTORIC REVIEW General Standards – 1. Windows, doors, and screens The proposed project replaces historic-age windows that do not appear to be deteriorated beyond repair. Proposed window replacements at main and secondary elevations alter the window patterns, materials, opening sizes, and configurations. WINDOWS - The existing single-pane windows are a weak link in the building’s thermal envelope. Even with storm windows or weather-stripping, single panes cannot match the insulation of modern glazing. - The current windows are steel and single pane. The steel is corroded and cracked in all windows. - The glazing has deteriorated completely. The exposure to weather/rain/UV radiation gradually breaks down the glazing compounds leading to cracks, shrinkage, and loss of adhesion - The existing glass are cracked all in the same general areas. 1 CRACKINGSINGLE PANECRACKINGPULLING OFF THE FRAMING RUST AND CRACKINGON STEEL AND GLASS 1412 PRESTON HISTORIC REVIEW General Standards – - The expansion and contraction over time has led to the steel to pull away from the brick - Traditional glazing putty, often linseed oil-based, hardens and becomes brittle over time, making it prone to cracking and falling out. - Steel windows from the 1950s are extremely difficult to repair due to limited availability of materials and skilled labor. The cost of repair is prohibitive and exceeds the cost of replacement - The existing windows are sitting directly brick to window contact, no sheathing or insulation, as well as no - Rust and corrosion – As steel frames corrode, they expand, putting pressure on the glazing and causing it to fail flashing. or detach from the glass. 2 CRACKING, DIRECT BRICK TO WINDOW PLACEMENT , LEAKAGESTEEL HAS CRACKING, NO FLASHING, DIRECT WINDOW TO BRICK APPLICATION 1412 PRESTON HISTORIC REVIEW General Standards – Aluminum Clad replacements The design standards documentation notes that simple measures like weather-stripping and window film are the first line of defense , and we have evaluated those. However, given the persistent energy loss and comfort issues, we are proposing to replace the single panes with insulated (double-glazed) glass units. - We also evaluated the weather stripping and film will not solve the issue of the incorrect construction application - Air leakage and thermal retention:Replacing with Sierra Pacific Wood Aluminum Clad windows will drastically reduce air leakage and heat transfer while preserving the historic frames’ appearance. Notably, the City’s guidelines even suggest retrofitting historic windows with insulated, low-E glass when …
T E E R T S N N Y L T S E W 580 SF 695 SF 450 SF 450 SF 1345 SF FRONT UNIT AREA EXISTING ADDITION GARAGE SECOND FLOOR CONDITIONED AREA SQ. FT. 580 SF. 695 SF. 450 SF. 1,145 SF. 2,420 SF. REAR UNIT AREA FIRST FLOOR FRONT PORCH REAR PORCH SECOND FLOOR GARAGE SQ. FT. 1,345 SF. 64 SF. 142 SF. 1,551 SF. 450 SF. CONDITIONED AREA 2,896 SF.
T E E R T S N N Y L T S E W 1130 SF 1350 SF 1345 SF 1240 SF 450 SF 450 SF 450 SF 450 SF FRONT UNIT AREA FIRST FLOOR FRONT PORCH GARAGE SECOND FLOOR CONDITIONED AREA SQ. FT. 1130 SF. 104 SF. 450 SF. 1,684 SF. 2,814 SF. REAR UNIT AREA FIRST FLOOR FRONT PORCH REAR PORCH SECOND FLOOR GARAGE SQ. FT. 1,345 SF. 64 SF. 142 SF. 1,551 SF. 450 SF. CONDITIONED AREA 2,896 SF.