Versión en español a continuación. Historic Landmark Commission Meeting of the Architectural Review Committee Monday, March 14, 2022, 4:30 PM Public comment will be allowed in-person or remotely by telephone. Registration no later than noon the day before the meeting is required for remote participation. Community members may register for public communication but may not speak on specific cases on the agenda. The opportunity for public input on specific cases will occur at a subsequent meeting of the Historic Landmark Commission. This meeting is not televised. Community members may also register to receive call in information and listen to the meeting via telephone. To register for remote participation: • Call or email the board liaison at (512) 974-3393 or preservation@austintexas.gov no later than noon, Sunday, March 13, 2022 (the day before the meeting). The following information is required: speaker name, item number(s) they wish to speak on, whether they are for/against/neutral, email address and telephone number (must be the same number that will be used to call into the meeting). • Once a request to speak has been made to the board liaison, the information to call on the day of the scheduled meeting will be provided either by email or phone call. • Speakers must call in at least 15 minutes prior to meeting start time in order to speak, late callers will not be accepted and will not be able to speak. • Speakers will be placed in a queue until their time to speak. • Handouts or other information may be emailed to preservation@austintexas.gov by noon the day before the scheduled meeting. This information will be provided to committee members in advance of the meeting. Reunión del Historic Landmark Commission, Architectural Review Committee FECHA de la reunion 14 de marzo 2022 a las cuatro y media de la tarde (4:30 p.m.) Se permitirán comentarios públicos en persona o de forma remota por teléfono. Se requiere registro a más tardar al mediodía del día anterior a la reunión para la participación remota. Los miembros de la comunidad pueden registrarse para la comunicación ciudadana pero no pueden hablar sobre casos específicos en la agenda. La oportunidad para la opinión del público sobre casos específicos ocurrirá en una reunión posterior de la Comisión de Monumentos Históricos. Esta reunión no es televisada. Los miembros de la comunidad también pueden registrarse para recibir información de llamadas y escuchar la reunión por teléfono. …
WINDSOR RESIDENCE 3908 Avenue H Austin, Texas 78751 Total Conditioned Building area for Addition and Renovations of existing Residence 2,396 SQ. FT. 100% Permit Set - 11/15/2021 TEAM MEMBERS OWNER / CONTACT STEPHAN WINDSOR 3908 AVENUE H AUSTIN, TEXAS 78751 ARCHITECT OF RECORD DOUG FREY FREY ARCHITECTS, INC. P.O. BOX 5742 AUSTIN, TEXAS 78763 dfrey@freyarchitects.com (512) 330-0334 STRUCTURAL ENGINEER SAMUEL COVEY P.E. FORT STRUCTURES PC 2235 EAST 6TH ST. #105 AUSTIN, TEXAS 78702 sam@fortstructures.com (512) 817-9264 GENERAL CONTRACTOR PROJECT INFORMATION CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH APPLICABLE CODES OR STATUS WHETHER OR NOT SPECIFICALLY REFERENCED IN THE CONSTRUCTION DOCUMENTS • • • • • INTERNATIONAL RESIDENTIAL CODE, 2021 EDITION, AND LOCAL AUSTIN AMENDMENTS INTERNATIONAL ENERGY CONSERVATION CODE, 2021 EDITION, AND LOCAL AUSTIN AMENDMENTS CITY OF AUSTIN LDC CHAPTER 25-2 SUB-CHAPTER F CITY OF AUSTIN LDC CHAPTER 25-6 APPENDIX A PARKING REQUIRMENTS CITY OF AUSTIN 2012 ORDINANCE #20120112-086 PART 8, SECTION 8 SCOPE OF WORK SHEET INDEX SHEET INDEX SHEET INDEX Sheet Name Sheet Name Sheet Number Sheet Number GENERAL CS.01 SURVEY A0.10 A0.11 COVER SHEET PROPERTY SURVEY (11 x 17) PLOT PLAN (11 x 17) ARCHITECTURAL SITE PLAN ARCHITECTURAL LDC 25-2 SUB-CHAPTER F A0.20 A0.21 A0.22 A0.23 SITE AND BUILDING AREA CALCULATIONS SIDE SETBACK PLANES SITE PLAN BUILDING TENT ELEVATIONS BUILDING TENT ELEVATIONS EXISTING FLOOR PLAN WITH DEMOLITION PLAN NOTES EXISTING EXTERIOR ELEVATIONS WITH DEMOLITION NOTES ARCHITECTURAL LDC 25-2 SUB-CHAPTER F D0.10 D0.20 ARCHITECTURAL A1.10 A1.20 A1.21 A1.30 A1.31 A1.40 EXISTING BUILDING FLOOR PLAN NEW FIRST FLOOR BUILDING FLOOR PLAN NEW SECOND FLOOR BUILDING FLOOR PLAN EXISTING BUILDING ROOF PLAN NEW ROOF PLAN POWER, DATA AND REFLECTED CEILING PLAN A2.10 A2.11 A2.12 A2.13 A3.10 A3.11 A3.12 EXISTING EXTERIOR ELEVATIONS NEW EXTERIOR ELEVATIONS NEW EXTERIOR ELEVATIONS BUILDING SECTIONS ELEVATIONS INTERIOR ELEVATIONS INTERIOR ELEVATIONS INTERIOR ELEVATIONS X X X X X X X X X X X X X X X X X X X X X X PROJECT DATA VICINITY MAP X X X X X X X X X X X X X X X X X X X X X X X PROJECT LOCATION I E C N E D S E R R O S D N W I H e u n e v A 8 0 9 3 1 5 7 8 7 S A X E T , N I T S U A DESIGN ARCHITECT: 3 6 7 8 7 S A X …
E 44TH STREET (60' R.O.W.) INLET S 62°17'58" E 124.61' Outline of existing roof overhang Note: WW connection to be determined in field. Tap card for City of Austin is illegible. 1009 Blanco St. Austin, TX 78703 www.shillingtonarch.com Existing 1 Story House Existing to remain G WM Existing Walk Concrete PROPERTY INFORMATION Legal Description LOT 31&32 BLK 17 HYDE PARK ADDN NO 1 SF-3-HD-NCCD-NP Zoning Floodplain Erosion Hazard Zone No No AC AC N 62°17'58" W 124.61' Site Plan: Demo SCALE: 1/8" = 1'-0" 2 Power Pole Existing brick apron to remain Existing gravel drive to remain Existing 1 Story Garage to be removed Y E L L A ) . . W O R . ' 2 1 ( N 2 7 ° 0 1 5 5 " ' E 5 0 . 0 0 ' Power Pole Y E L L A ) . . W O R . ' 2 1 ( N 2 7 ° 0 1 5 5 " ' E 5 0 . 0 0 ' 12 .6 ' 15 .9' 2.0' 3.0' 3.0' New Concrete Runners ' 0 . 5 3 S e t b a c k 1 0 ' - 0 " B a c k Y a r d ' 9 . 4 Proposed Porch Wood Proposed Walk Concrete Proposed 2 Story Addition E E Existing curb cut and paved/gravel apron to remain. E 44TH STREET (60' R.O.W.) INLET NCCD Ordinance No. 020131-20(8)(8)(b) A porch may extend b. on a street other than an avenue, a maximum of five feet in front of a street yard setback. S 62°17'58" E 124.61' Existing house sits beyond street side yard setback. Outline roof overhang Note: WW connection to be determined in field. Tap card for City of Austin is illegible. Vertical 7.5' clearance from overhead power lines that crosses lot 15'-0" Street Side Yard Setback Existing 1 Story House Existing to remain (Dimensions per as-builts) WM Existing Walk Concrete Exist. Cov'd Porch Conc. G 2 5 ' - 0 " F r o n t Y a r d S e t b a c k Exist. Cov'd Porch Conc. H E U N E V A ) . . W O R . ' 0 6 ( ) . . W O R . ' 0 6 ( H E U N E V A N S 2 7 ° 0 …
Willson Residence 4314 Avenue H Austin TX 78751 Existing siding, existing windows and screens to remain. Existing front door and details to remain. Existing steps and railings to remain. Porch deck to be replaced due to rot. View from Avenue H For Review 03.07.22 Existing garage to be removed Willson Residence 4314 Avenue H Austin TX 78751 View from 44th Street For Review 03.07.22 Existing garage to be removed Willson Residence 4314 Avenue H Austin TX 78751 View from 44th Street For Review 03.07.22 Door replaced with new window New addition here Willson Residence 4314 Avenue H Austin TX 78751 Back of Existing House For Review 03.07.22 No changes. Existing siding, existing windows and screens to remain. Willson Residence 4314 Avenue H Austin TX 78751 View from South Prop. Line For Review 03.07.22
SYMBOL LEGEND FFE 0" FFE OR GRADE ELEVATION AS NOTED EXTERIOR ELEVATION 101 DOOR NUMBER 101 WINDOW NUMBER A WALL TYPE NEW WALL (PLAN VIEW) EQUAL DIMENSIONS IN LINE A-211 4 2 A-501 1 1 3 1 1 A-311 A-211 INTERIOR ELEVATION SECTION CL CENTERLINE PLAN/ ELEVATION DETAIL PROJECT INFORMATION LEGAL DESCRIPTION: ZONING: LOT 27-29 BLK 16 HYDE PARK ADDITION No. 2 SF-3-HD-NCCD-NP YEAR CONSTRUCTED: 1930 APPLICABLE CODES: International Residential Code, 2021 OCCUPANCY: R-1 CONSTRUCTION TYPE: V-B ABBREVIATIONS & # @ And Pound At Air Conditioning A/C ACOUST Acoustical ADD'L Additional ADJ AFF AHJ AHU APPROX Approximately ARCH ASTM American Society for Testing Adjacent Above Finish Floor Authority Having Jurisdiction Air Handling Unit Architect & Materials Equal Spacing, Equivalent EQ Equipment EQUIP EXH Exhaust EXST'G Existing Exterior EXT FAR FF(E) FIN FIXT FLR FT FTG FV FV HT Floor-Area Ratio Finished Floor (Elevation) Finish(ed) Fixture Floor Feet, Foot Footing Field Verify Field Verify Height BFE Base Flood Elevation BRD Board Building BLDG BDRM Bedroom BTM BTWN Between Bottom Cabinet Corner Bead Cubic Feet Control Joint Centerline Ceiling Closet Clear Column CAB CB CF CJ CL CLG CLO CLR COL COMP Composite CONC CONST Construction CONT COORD Coordinate, Coordination Critical Root Zone CRZ Cover CVR Cold Water CW Continuous Concrete Deep, Depth, Dryer Double D DBL DEMO Demolish, Demolition Double Hung DH Diameter DIA Diagonal, Diagonally DIAG Down DN Downspout DS Dishwasher DW Drawing DWG Drawer DWR East Each Expansion Joint Electric Meter Equal Spacing, Equivalent Equipment E EA EJ EM EQ EQUIP EXST'G Existing Exterior EXT Gauge GA Galvanized GALV General Contractor GC Ground Fault Circuit Interrupt GFCI Glass GL GM Gas Meter GPM Gallons Per Minute GR GRND Ground GSF GYP BD Gypsum Wall Board Gross Square Feet Grade Hose Bib Header HB HDR HDWR Hardware HORIZ Horizontal HR HT HTG HVAC Hour Height Heating Heat/Ventilation/ Air Conditioning Id Est (That Is) Inches Inaccessible Including Information Insulation Interior Joint Joist Kitchen I.E. IN INAC INCL INFO INSUL INT JNT JST KIT L LAM LAV LB(S) LF LOC LP LT LVR Length Laminated Lavatory Pound(s) Linear Foot Limits of Construction Light Pole or Lightning Protection Light Louver MFGR Manufacturer MAX Maximum MECH Mechanical M/E MEP Mechanical/Electrical Mechanical, Electrical, & Plumbing Minimum MIN MISC Miscellaneous MTD Mounted MTL Metal N NA NIC NO NSF NTE NTS North Not Applicable Not in Contract Number Net Square Feet Not to Exceed Not to …
4210 Ave C ca. 1930 Hyde Park Local and National Register Historic District Mark and Alexandra Floreani, Homeowners REPAIR SIDING OR REPLACE IN-KIND. MASONRY REPAIR. REPAIR FOUNDATION SKIRT. East elevation REMOVE EXISTING SECOND FLOOR AND FLAT ROOF. Southeast corner REMOVE PORCH STOOP @ SOUTH ELEVATION Side porch on south elevation NEW ROOF AT SECOND FLOOR TO MATCH HISTORIC PITCH AND DETAILING – REF ELEVATIONS NEW GUTTERS AND DOWNSPOUTS. REPLACE EXISTING FLAT ROOF ON SOUTH ADDITION WITH NEW GABLED ROOF. NEW ROOF TO MATCH EXISTING Southeast corner REPAIR, REPAINT AND REGLAZE EXISTING WINDOWS AND DOORS IN-KIND WHERE DETERIORATED. West elevation REMOVE NORTH DOOR OF BACK PORCH. North elevation facing southeast 15’ REPLACE EXISTING SECOND FLOOR ADDITION TO MATCH HISTORIC SIDING AND TRIM AND COMPLIMENTARY IN DETAILING. NEW ROOF FORM AND FENESTRATION SIMILAR TO HISTORIC. NEW SECOND FLOOR ADDITION SET BACK FROM FRONT FACADE BY 15’. MASONRY REPAIR AS NEEDED. North elevation facing southwest REPLACE SCREENS AND ADD WOOD WAINSCOT. Screened porch on west (rear) elevation
Rear VERIFY SIZES AND HEAD HEIGHT W/ PLANS AND ELEVATIONS; CONTACT DESIGNER W/ ANY DISCREPANCIES: TEMPER NOT SPECIFIED WINDOW SCHEDULE WINDOW # SIZE HEAD HEIGHT TYPE COMMENTS DOOR # SIZE INT / EX COMMENTS DOOR SCHEDULE 6'0"X5'0" 2'0"X3'0" 4'0"X8'0" 4'0"X8'0" 4'0"X8'0" 3'0"X8'0" 3'0"X8'0" 4'0"X8'0" 4'0"X8'0" 4'0"X8'0" 5'0"X6'0" 3'0"X6'0" 2'0"X3'0" 3'0"X6'0" 5'0"X6'0" 4'0"X6'0" 2'6"X6'0" 2'6"X6'0" 5'0"X6'0" 4'0"X3'0" 4'0"X3'0" 4'0"X3'0" 3'0"X7'0" 2'0"X3'0" 2'0"X3'0" 8'0"X7'0" 3'0"X6'0" 9'0" 9'0" 9'0" 9'0" 9'0" 9'0" 9'0" 9'0" 9'0" 9'0" 7'6" 7'6" 7'6" 8'0" 8'0" 8'0" 8'0" 8'0" 8'0" 8'0" 8'0" 7'0" 7'0" 7'0" HEADER HEADER HEADER FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED CASEMENT EGRESS CASEMENT EGRESS CASEMENT EGRESS A B C D E F G H I J K L M N O P Q R S T U V W X Y Z AA BB CC DD EE GARAGE ACCESSIBLE ROUTE DOOR - ADA THRESHOLD ACCESSIBLE ROUTE DOOR FULL LITE FRONT DOOR 8'X8'0" 3'0"X8'0" 2'8"X8'0" 3'0"X9'0" 2'6"X8'0" 8'0"X9'0" 4'0"X8'0" 2'6"X8'0" 2'6"X8'0" 4'0"X8'0" 2'6"X8'0" 5'0"X8'0" 2'6"X8'0" 8'0"X8'0" 2'6"X8'0" 2'6"X8'0" 2'4"X8'0" 3'0"X9'0" 8'0"X8'0" 2'6"X8'0" 2'6"X8'0" 4'0"X8'0" EX EX INT EX INT EX INT INT INT INT INT INT INT EX INT INT INT EX EX INT INT INT 2 PANEL SLIDER DOUBLE DOORS DOUBLE DOORS DOUBLE DOORS 2 PANEL SLIDER POCKET DOOR FULL LITE FRONT DOOR 2 PANEL SLIDER DOUBLE DOORS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 DOOR NOTES - UNLESS OTHERWISE NOTED ALL DOORS TO BE FLUSH PANEL AND SOLID CORE - ALL BASEBOARDS AND DOOR TRIM TBD All rights reserved. All designs, drawings, plans & specifications are the property of RODENBEG D/D LLC. Purchaser's rights are conditional & limited to a one-time use to construct a single project on the site & use is limited specifically to such property. The use or reproduction of these plans concerning any other construction is strictly prohibited without the written permission of RODENBERG D/D LLC 804 RUTHERFORD PL NASH GARRISON REVISIONS NO 1 ISSUE PERMIT DATE 11/26/20 PROJECT OWNER NOTES SEAL & SIGNATURE DESIGNER RODENBERG DESIGN 1702 EVERGREEN DR AUSTIN, TX 78704 512-796-5995 RYAN@RODENBERGDESIGN.COM STRUCTURAL ENGINEER SEC SOLUTIONS LLC MARCOS DEQUEIROGA, PE 407 FOREST STREET LIBERTY HILL, TX 78642 512-215-4364 SHEET TITLE SCHEDULES SHEET NUMBER A0.2 COVERED 67 SF DRIVEWAY 174 …