Planning CommissionAug. 13, 2024

28 International Residential Code and International Building Code IBC Adoption Review — original pdf

Backup
Thumbnail of the first page of the PDF
Page 1 of 19 pages

PROPOSED IBC 2024 CODE V1, DRAFT SUBJECT TO  ADDITIONAL CHANGES  AN ORDINANCE REPEALING AND REPLACING DIVISION 1 OF ARTICLE 1 OF CITY CODE CHAPTER 25‐12 RELATING  TO THE INTERNATIONAL BUILDING CODE; REPEALING AND REPLACING ARTICLE 10 OF CITY CODE CHAPTER 25‐12  RELATING TO THE INTERNATIONAL EXISTING BUILDING CODE; AND CREATING OFFENSES.  BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF AUSTIN:  PART 1. City Code Chapter 25‐12 (Technical Codes) is amended to repeal and replace Division 1 of Article 1  (Building Code) to read:  DIVISION 1. INTERNATIONAL BUILDING CODE AND LOCAL AMENDMENTS  § 25‐12‐1 INTERNATIONAL BUILDING CODE. (A) The International Building Code, 2021 2024 Edition, published by the International Code Council ("2021 2024 International Building Code") is adopted and incorporated by reference into this section with the deletions in Subsection (B) and the amendments in Section 25‐12‐3 (Local Amendments to the International Building Code). (B) The following provisions of the 20241 International Building Code are deleted. 414.1.3305.2.3  503.1.4 plus subsections  308.2.3  Chapter 9 308.2.4  1612 plus subsections  427.6  2901.1503.1.4  1108.6.4.2  1301.1  3102.5Chapter 9  103 plus subsections  Table 1004.5308.3   3201.11008.2.1  1507.8 plus  subsections  1507.9 plus  subsections  1607.8.2  1612 plus  subsections  2901.1  2902.2  2902.6  3102.5  3201.1  3202.1  Table 2901.1  Footnote (e)  1010.1.2308.3.1.1  1010.3.3 308.3.2  3202.1 1009.3  3202.3.41010.1.2  1102.1308.5  1204 plus subsections  308.5.1  1301.1 308.5.3  1507.8 plus subsections  308.5.4  1507.9 plus subsections  310.2  1607.8.2310.4.1  406.4.3   1010.2.7  1010.3.3  1101.2 1102.1  1108.6.1.2  1108.6.2.2.2  1108.6.2.3.2  1108.6.3  Page 1 of 19  101.4.1  101.4.2  101.4.3  104.32.1  105.1.1  105.2  105.5  107.2.6  110.3  112.3  113 plus subsections  305.2  305.2.2  Table 1004.5   414.1.3                          (C) The following definition is deleted from Section 202.2.1 (General Definitions) of the 2021 International Building  Code:  (C) The city clerk shall file a copy of the 20241 International Building Code with the official ordinances of  FOSTER CARE FACILITIES.  (B) the City.    § 25‐12‐2 CITATIONS TO THE BUILDING CODE.  In the City Code, "Building Code" means the 20241 International Building Code adopted in Section 25‐12‐1  (International Building Code) as amended by Section 25‐12‐3 (Local Amendments to the International Building  Code). In this article, "this code" means the Building Code.  § 25‐12‐3 LOCAL AMENDMENTS TO THE INTERNATIONAL BUILDING CODE.  Each provision in this section is a substitute for the identically numbered provision deleted in Section 25‐12‐ 1(B) (International Building Code) or is an addition to the 20241 International Building Code.  [A] 101.4.1 Gas. The provisions of the International Fuel Gas Code and the Plumbing Code shall apply to the  installation of gas piping from the point of delivery, gas appliances, and related accessories as covered in this code.  The Plumbing Code supersedes the International Fuel Gas Code to the extent of conflict. These requirements apply  to gas piping systems extending from the point of delivery to the inlet connections of appliances and the  installation and operation of residential and commercial gas appliances and related accessories.   [A] 101.4.2 Mechanical. The provisions of the International Mechanical Code and the Mechanical Code shall apply  to the installation, alterations, repairs, and replacement of mechanical systems, including equipment, appliances,  fixtures, fittings, and/or appurtenances, including ventilating, heating, cooling, air conditioning, and refrigeration  systems, incinerators, and other energy related systems. The Mechanical Code supersedes the International  Mechanical Code to the extent of conflict.   [A] 101.4.3 Plumbing. The provisions of the International Plumbing Code and the Plumbing Code shall apply to the  installation, alteration, repairs, and replacement of plumbing systems, including equipment, appliances, fixtures,  fittings, and appurtenances, and where connected to a water or sewage system and all aspects of a medical gas  system. The Plumbing Code supersedes the International Plumbing Code to the extent of conflict. The provisions of  the International Private Sewage Disposal Code and the Plumbing Code shall apply to private sewage disposal  systems. The Plumbing Code supersedes the International Private Sewage Code to the extent of conflict.   101.4.8 Wildland‐Urban Interface. The provisions of the International Wildland‐Urban Interface Code shall apply  to matters governing the construction, alteration, movement, repair, maintenancemaintenance, and use of any  building, structurestructure, or premises within the wildland‐urban interface areas in this jurisdiction.   101.4.9 Building Criteria Manual. Additional information on procedures and rules for administration of this code  are available in the Building Criteria Manual.   SECTION 103 BUILDING OFFICIAL  103.1 Building Official. The building official administers, enforces, and interprets this code. The building official  may designate one or more deputy building officials.   [A] 104.32.1 Determination of Substantially Improved or Substantially Damaged Existing Buildings and  Structures in Flood Hazard Areas. For applications for reconstruction, rehabilitation, repair, alteration, addition or  Page 2 of 19      other improvement of existing buildings or structures located in flood hazard areas, the building official shall  examine or cause to be examined the construction documents and shall prepare a finding with regard to the value  of the proposed work. If the work is a substantial improvement as defined in Section 25‐12‐52 (Definitions), the  proposed work shall comply with Article 3 (Flood Hazard Areas).   [A] 105.1.1 Annual Permit. Instead of an individual permit for each alteration to an already approved electrical,  gas, mechanical or plumbing installation, and minor building alterations and repairs, the building official is  authorized to issue an annual permit upon application to any person, firm or corporation regularly employing one  or more qualified trade persons in the building, structure or on the premises owned or operated by the applicant  for the permit. The facility shall maintain records on all work performed under the annual permit in accordance  with Section 105.1.2 (Annual Permit Records).   105.1.1.1 Authorized Scope of Work. See Building Criteria Manual, Section 1.1.2 (Building Inspection Processes) for  scope of work authorized under the annual permit.   [A] 105.2 Work Exempt from Permit. A permit is not required for the work described in this provision. Work  exempt from a permit shall still comply with this code and all other applicable laws and City Code requirements.   Building:  One‐story detached accessory structures used as tool and storage sheds, playhouses, shade cloth structures  constructed for outdoor covered areas that are not A2 or E occupancies, and similar uses, provided the floor  area is not greater than 120 square feet (11 m2 )2); provided they are not located within a flood hazard area.   Fences not over 7 feet (2,134 mm) high; provided they are not located within a flood hazard area.   Oil derricks; provided they are not located within a flood hazard area.   Retaining walls that are not over 4 feet (1,219 mm) in height measured from the bottom of the footing to the  top of the wall, unless supporting a surcharge or impounding Class I, II or IIIA liquids; provided they are not  located within a flood hazard area.   5.  Water tanks supported directly on grade if the capacity is not greater than 5,000 gallons (18,925 L) and the  ratio of height to diameter or width is not greater than 2:1; provided they are not located within a flood  hazard area.   Sidewalks and driveways not more than 30 inches (762 mm) above adjacent grade, and not over any  basement or story below and are not part of an accessible route; provided they are not located within a  flood hazard area.   Painting, papering, tiling, carpeting, cabinets, counter topscountertops, and similar finish work.   Temporary motion picture, television, and theater stage sets and scenery.   Prefabricated swimming pools accessory to a Group R‐3 occupancy that are less than 24 inches (610 mm)  deep, are not greater than 5,000 gallons (18,925 L) and are installed entirely above ground; provided they  are not located within a flood hazard area.   10.  Shade cloth structures constructed for nursery or agricultural purposes, not including service systems;  provided they are not located within a flood hazard area.   11.  Swings and other playground equipment accessory to detached one‐ and two‐family dwellings; provided  they are not located within a flood hazard area.   12.  Window awnings in Group R‐3 and U occupancies, supported by an exterior wall that do not project more  than 54 inches (1,372 mm) from the exterior wall and do not require additional support.   13.  Non‐fixed and movable fixtures, cases, racks, counters, and partitions not over 5 feet 9 inches (1,753 mm) in  height.   14.  Repair and replacement to gypsum board and backer board that are not part of a fire‐resistance‐rated wall, a  shear assembly, or wet areas if it is limited to a maximum of 96 square feet.   Page 3 of 19  1.  2.  3.  4.  6.  7.  8.  9.        15.  Emergency removal of water damaged material such as, but not limited to gypsum board, insulation, wood  paneling, etc., in order to avoid health hazard issues; a permit is required for the repairs.   16.  Repair to exterior siding that is not part of a fire‐rated assembly wall or shear assembly if it is limited to a  maximum of 96 square feet.   17.  Other work as determined by the building official.   Electrical:  Repairs and maintenance: Minor repair work, including the replacement of lamps or the connection of  1.  approved portable electrical equipment to approved permanently installed receptacles.   2.  Radio and television transmitting stations: The provisions of this code shall not apply to electrical  equipment used for radio and television transmissions, but do apply to equipment and wiring for a power supply  and the installations of towers and antennas.   Temporary testing systems: A permit shall not be required for the installation of any temporary system  3.  required for the testing or servicing of electrical equipment or apparatus.   Electrical work exempt from permit within the Electrical Code.   Exemptions authorized in the National Electrical Code  2.5.  Other work as determined by the building official.   Mechanical:  Plumbing:  Exemptions authorized in the Mechanical Code.   Other work as determined by the building official.   Exemptions authorized in the Plumbing Code.   Other work as determined by the building official.   105.5 Time Limits. Article 13 (Administration of Technical Codes) of this chapter establishes permit application  time limits and requirements applicable to permit expiration and reactivation, including a review fee for expired  permits.   [A] 107.2.6 Site Plan. The construction documents submitted with the application for permit shall be accompanied  by a site plan showing to scale the size and location of new construction and existing structures on the site,  distances from lot lines, the established street grades and the proposed finished grades, and as applicable, flood  hazard areas, floodways, and design flood elevations; and it shall be drawn in accordance with an accurate  boundary line survey. In the case of demolition, the site plan shall show construction to be demolished and the  location and size of existing structures and construction that are to remain on the site or plot. For a building or  structure involving below‐grade construction, the site plan shall show the location of proposed earth retention  system components allowed under Section 3202.1.4 (Earth Retention System Components). The building official is  authorized to waive or modify the requirement for a site plan when the application for permit is for alteration or  repair or when otherwise warranted.   108.5 Temporary Earth Retention Systems. Temporary earth retention system components used to facilitate  below‐grade construction of a building or structure shall conform to Sections 1811 (Earth Retention Systems) and  Section 3202.1.4 (Earth retention system components).   109.7 Plan Review Fees. An applicant shall pay a plan review fee, adopted by separate ordinance, when plans and  specifications are submitted for review under Section 107 (Submittal Construction Documents). The building official  shall charge an additional plan review fee if plans are incomplete or changed so as to require additional plan  review. The plan review fees referenced in this section are in addition to the permit fees referenced in Section  109.1 (Payment of fees).   Page 4 of 19  4.  1.  1.  2.  1.  2.        110.3 Required inspections. The building official, upon notification, shall make inspections set forth in Sections  110.3.1 through 110.3.12.1 and the Building Criteria Manual.   112.3 Authority to Disconnect Service Utilities. The building official shall have the authority to authorize  disconnection of utility service to the building, structure or system regulated by this code and the referenced codes  and standards in case of emergency where necessary to eliminate an immediate hazard to life or property, where  one or more circumstances listed in Section 15‐9‐101(A)(2) (Basis for Termination of Service) exist, or where such  utility connection has been made without the approval required by Section 112.1 or 112.2. The building official  shall provide notice in accordance with Section 15‐9‐106 (Notice of Service Disconnection) of the decision to  disconnect prior to taking such action. If not notified prior to disconnecting, the owner or the owner's authorized  agent or occupant of the building, structure or service system shall be notified in writing, as soon as practical  thereafter in accordance with Section 15‐9‐106 (Notice of Service Disconnection).   113 Building and Fire Code Board of Appeals. Regulations regarding the Building and Fire Code Board of Appeals  are found in Chapter 2‐1 (City Boards).   Section 202 Definitions.  202.1 Supplemental definitions. The definitions in this subsection apply throughout this code and supplement the  definitions in Section 202 (General Definitions) in the 20241 International Building Code.   BED AND BREAKFAST. A private residence having a limited number of sleeping rooms which are available for  transient guests who have paid for accommodations. For the different classifications of bed and breakfast  structures refer to Section 25‐2‐781 (Bed and Breakfast Residential Use Structures Classified).   START OF CONSTRUCTION. The date a permit is issued for new construction or substantial improvements to  existing structures if construction, repair, reconstruction, rehabilitation, addition, placement or other  improvement starts within 180 days from the date the permit is issued. Construction starts when permanent  construction of a building (including a manufactured home) is first placed and includes pouring a slab or footing,  installing pilings, or constructing columns. Permanent construction does not include preparing land (clearing,  excavating, grading, or filing); installing streets or walkways; excavating for a basement, footing, pier, or  foundation; or erecting temporary forms or installing accessory buildings not occupied as dwelling units or not part  of the main building. For a substantial improvement, construction starts when a wall, ceiling, floor, or other  structural part of a building is altered even if the alteration does not affect the external dimensions of the building.   SUBSTANTIAL DAMAGE. Damage of any origin sustained by a structure, whereby the cost of restoring the  structure to its before‐damage condition would equal or exceed 50 percent of the market value of the structure  before the damage occurred.   305.2 Group E, Day Care Facilities. This group includes buildings and structures, or portions thereof occupied by  more than six children older than 2½ years of age who receive educational, supervision, or personal care services  for fewer than 24 hours per day.   305.2.2 Six or Fewer Children. A facility having six or fewer children receiving such day care shall be classified as  part of the primary occupancy.   305.2.3 Six or Fewer Children in a Dwelling Unit. A facility such as the above within a dwelling unit and having six  or fewer children receiving such day care shall be classified as a Group R‐3 occupancy or shall comply with the  Residential Code.   308.2.3 Seven to 16 Persons Receiving Custodial Care. A facility housing not fewer than seven and not more than  16 persons receiving custodial care shall be classified as Group R‐4.   308.2.4 Six or Fewer Persons Receiving Custodial Care. A facility with six or fewer persons receiving custodial care  shall be classified as Group R‐3 or shall comply with the Residential Code provided an automatic sprinkler system is  installed in accordance with Section 903.3.1.3 or Section P2904 of the Residential Code.     Page 5 of 19      308.3 Institutional Group I‐2. Institutional I‐2 occupancy shall include buildings and structures used for medical  care on a 24‐hour basis for more than six persons who are incapable of self‐preservation. This group shall include,  but not be limited to, the following: detoxification facilities; hospitals; nursing homes; and psychiatric hospitals.   308.3.1.1 Condition 1. This occupancy condition shall include facilities that provide nursing and medical care but  do not provide emergency care, surgery, obstetrics or in‐patient stabilization units for psychiatric or detoxification,  including but not limited to nursing homes.   308.3.2 Six or Fewer Persons Receiving Medical Care. A facility with six or fewer persons receiving medical care  shall be classified as Group R‐3 or shall comply with the Residential Code provided an automatic sprinkler system is  installed in accordance with Section 903.3.1.3 or Section P2904 of the Residential Code.   308.5 Institutional Group I‐4, Day Care Facilities. Institutional Group I‐4 shall include buildings and structures  occupied by more than six persons of any age who receive custodial care for fewer than 24 hours per day by  persons other than parents or guardians, relatives by blood, marriage, or adoption, and in a place other than the  home of the person cared for. This group shall include, but not be limited to, the following: adult day care and child  day care.   308.5.1 Classification as Group E. A child care facility that provides care for more than six but no more than 100  children 2½ years or less of age, where the rooms in which the children are cared for are located on a level of exit  discharge serving such rooms and each of these child care rooms has an exit door directly to the exterior, shall be  classified as Group E.   308.5.3 Six of Fewer Persons Receiving Care. A facility having six or fewer persons receiving custodial care shall be  classified as part of the primary occupancy.   308.5.4 Six or Fewer Persons Receiving Care in a Dwelling Unit. A facility such as the above within a dwelling unit  and having six or fewer persons receiving custodial care shall be classified as a Group R‐3 occupancy or shall  comply with the International Residential Code, provided an automatic sprinkler system is installed in accordance  with Section 903.3.1.3 (NFPA 13D sprinkler systems) or with Section P2904 of the Residential Code.   310.2 Residential Group R‐1. Residential occupancies containing sleeping units where the occupants are primarily  transient in nature including: boarding houses (transient) with more than 10 occupants, congregate living facilities  (transient) with more than 10 occupants, hotels (transient), motels (transient), and bed and breakfast  establishments.   Exceptions: Compliance with Section 903.2.8 (Group R) is not required for a single structure Group R‐1 Bed and  Breakfast occupancy described in Section 25‐2‐781 (Bed and Breakfast Residential Use Structures Classified) when  the owner resides within the Bed and Breakfast occupancy and provided that:   The structure is a detached single‐family home that was legally constructed and occupied as a single‐ 1.  family residence prior to January 1, 2006;   2.  The total number of sleeping rooms did not increase after January 1, 2006;   3.  The residence is protected by a monitored residential style fire/security system with an appropriate  automatic smoke detection system installed throughout the residence with occupant notification devices in  accordance with Section 907.5 (Occupant notification systems); and   The residential style fire/security system shall be inspected, tested and maintained in accordance with  4.  Section 907.8 (Inspection, testing and maintenance).   310.4.1 Care Facilities within a Dwelling. Care facilities for six or fewer persons receiving care that are within a  single‐family dwelling are permitted to comply with the Residential Code, provided an automatic sprinkler system  is installed in accordance with Section 903.3.1.3 (NFPA 13D sprinkler systems) or with Section P2904 of the  Residential Code.   Exception: Compliance with Section 903.3.1.3 (NFPA 13D sprinkler systems) is not required for adult care and child  care facilities that are within the proprietor's single‐family home; provided that the home was permitted prior to  October 1, 2010.    Page 6 of 19      406.4.3 Ramps. The minimum width and depth of parking spaces and vehicle circulation aisles shall be in  accordance with the Austin Transportation Criteria Manual, Table 9‐1 or Table 9‐2 (residential and low‐use garages  only). Vehicle ramps shall not be considered as required exits unless pedestrian facilities are provided. Vehicle  ramps that are utilized for vertical circulation as well as for parking shall not exceed a slope of 1 unit vertical in 15  unit's horizontal (6.67‐percent slope).   414.1.3 Information Required. Separate floor plans shall be submitted for buildings and structures with an  occupancy in Group H, identifying the locations of anticipated contents and processes, to reflect the nature of each  occupied portion of every building and structure. The floor plan shall identify the hazards associated with the  contents and processes. A report identifying hazardous materials including, but not limited to, materials  representing hazards that are classified in Group H to be stored or used, shall be submitted and the methods of  protection from such hazards shall be indicated on the construction documents. The building official or fire  marshal may also require a technical opinion that addresses the adequacy of the protective measures provided.  The opinion and report shall be prepared by a qualified individual, firm or corporation approved by the building  official and fire marshal, andmarshal and shall be provided without charge to the City.   420.12 Single Exit Stairway in Certain R-2 applications. Occupancy Classification, Residential Group R-2: Apartment Houses are permitted to be served by a single exit under the following conditions: 1.The building has not more than 5 stories above grade plane, and 2. The building shall not qualify as a high-rise as defined in the IBC. 3.. The building shall contain no more than four dwelling units on any floor. 4.. The building shall be of Type 1, Type 2A, or Type 4 Construction and shall also be equipped throughout with an automatic sprinkler system in accordance with NFPA 13. 5.. There shall be no more than two single exit stairway conditions on the same property. Each single exit building shall be separated by a fire separation distance of a min. 10 feet. 6.. An exterior stairway or interior exit stairway shall be provided. The interior exit stairway, including any related exit passageway, shall be pressurized in accordance with subsection 909.20. Doors in the stairway shall swing into the interior exit stairway regardless of the occupant load served, provided that doors from the interior exit stairway to the building exterior are permitted to swing in the direction of exit travel. 7.. A corridor shall separate each dwelling unit entry/exit door from the door to an interior exit stairway, including any related exit passageway, on each floor. Dwelling unit doors shall not open directly into an interior exit stairway. Dwelling unit doors are permitted to open directly into an exterior stairway. 8. There shall be no more than 20 feet (6096 mm) of travel distance to the exit stairway from the entry/exit door of any dwelling unit. 9.. The exit access travel distance measured in accordance with IBC section 1017 shall not exceed 125 feet (38100 mm). 10..The exit shall not terminate in an egress court where the court depth exceeds the court width unless it is possible to exit in either direction to the public way. 11. Elevators shall be pressurized in accordance with section 909.21 or shall open into elevator lobbies that comply with section 713.14. Page 7 of 19          12.. Elevators shall be occupant evacuation elevators as per section 3008. The elevator shall be identified by the international symbol for emergency medical services (star of life) per section 3002.4. 13.. Other occupancies are permitted in the same building, provided the building is of either type 1A or podium construction and complies with all the requirements of this code. Other occupancies shall not communicate with the Group R occupancy portion of the building or with the single-exit stairway. Exception: parking garages and occupied roofs accessory to the Group R occupancy are permitted to communicate with the exit stairway. 14.. The exit serving the Group R occupancy shall not discharge through any other occupancy, including an accessory parking garage. 15.. Other than required exit doors with a one-hour fire-resistance rating, there shall be no openings within 10 feet (3048 mm) of unprotected exterior openings into the stairway. 16.. Single exit stairway width shall be double the required stair width per IBC section 1011.2. 17.. Roof top occupancy shall not exceed 49 occupants. 18.. Each dwelling unit shall have a minimum of one operable Emergency Escape and Rescue Opening per section 1031.3.3  503.1.4 Occupied Roofs. A roof level or portion thereof shall be permitted to be used as an occupied roof provided  the occupancy of the roof is an occupancy that is permitted by Table 504.4 for the story immediately below the  roof. The area of the occupied roofs shall not be included in the building area as regulated by Section 506. An  occupied roof shall not be included in the building height or number of stories as regulated by Section 504,  provided that the penthouses and other enclosed rooftop structures comply with Section 1511.   Exceptions:  1.  The occupancy located on an occupied roof shall not be limited to the occupancies allowed on the story  immediately below the roof where the building is equipped throughout with an automatic sprinkler system  in accordance with Section 903.3.1.1 or 903.3.1.2 and occupant notification in accordance with Sections  907.5.2.1 and 907.5.2.3 is provided in the area of the occupied roof. Emergency voice/alarm communication  system notification per Section 907.5.2.2 shall also be provided in the area of the occupied roof where such  system is required elsewhere in the building.   2.  Assembly occupancies shall be permitted on roofs of open parking spaces of Type I or Type II construction, in  accordance with the exception to Section 903.2.1.6.   503.1.4 Occupiable roofs. A roof level or portion thereof shall not be used as an occupiable roof unless the  occupancy of the roof is an occupancy that is permitted by Table 504.4 for the story immediately below the roof.  The area of the occupiable roofs shall not be included in the building area as regulated by Section 506. An  occupiable roof shall not be included in the building height or number of stories as regulated by Section 504,  provided that the penthouses and other enclosed rooftop structures comply with Section 1511.  Exceptions:  1. The occupancy located on an occupiable roof shall not be limited to the occupancies allowed on the story  immediately below the roof where the building is equipped throughout with an automatic sprinkler  system in accordance with Section 903.3.1.1 or 903.3.1.2 and occupant notification in accordance with  Sections 907.5.2.1 and 907.5.2.3 is provided in the area of the occupiable roof. Emergency voice/alarm  communication system notification per Section 907.5.2.2 shall also be provided in the area of the  occupiable roof where such a system is required elsewhere in the building.  2. Assembly occupancies shall be permitted on roofs of open parking spaces of Type I or Type II  Page 8 of 19        construction, in accordance with the exception to Section 903.2.1.6.  3. An open noncombustible trellis or similar overhead shading device complying with the structural  requirements of this code shall not be considered an enclosure, as a covering or roof provided that the  trellis or shade has an evenly distributed net free area of 50 percent or greater.   503.1.4.1 Enclosures over occupiable roof areas. Elements or structures enclosing the occupiable roof areas shall  not extend more than 48 inches (1220 mm) above the surface of the occupiable roof.  Exceptions:  1. Penthouses constructed in accordance with Section 1511.2 and towers, domes, spires, and cupolas  constructed in accordance with Section 1511.5.  2. Elements or structures enclosing the occupiable roof areas where the roof deck is located more than 75  feet (22 860 mm) above the lowest level of fire department vehicle access.  503.1.4.2 Interstitial Spaces Beneath Rooftop Occupancies. When decks or other walking surfaces are constructed  above a roof to facilitate rooftop occupancy, the space between the roof surface and the deck or walking surface  shall be constructed in a manner that precludes the accumulation of material between the roof surface and the  deck or walking surface and that prevents the introduction of ignition sources to the space and allows for proper  roof drainage.   CHAPTER 9 FIRE PROTECTION AND LIFE SAFETY SYSTEMS.  901.1 Scope. The provisions of this chapter shall specify where fire protection and life safety systems are required  and shall apply to the design, installation and operation of fire protection and life safety systems. For those  requirements, see Chapter 25‐12, Article 7 (Fire Code).   TABLE 1004.5 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT   Function of Space  Accessory storage areas, mechanical equipment room   Agricultural building   Aircraft hangars     Airport terminal     Baggage claim     Baggage handling     Concourse     Waiting areas   Assembly     Gaming floors (keno, slots, etc.)     Exhibit Gallery and Museum   Assembly with fixed seats     Assembly without fixed seats     Concentrated (chairs only‐ not fixed)    Standing space or queuing space     Unconcentrated (tables and chairs)   Bowling centers, allow 5 persons for each lane including 15 feet of  runway, and for additional areas   Business areas   Concentrated business use areas  Courtrooms—other than fixed seating areas   Day care   Page 9 of 19  Occupant Load Factora  300 gross   300 gross   500 gross     20 gross   300 gross   100 gross   15 gross     11 gross   30 net   See Section  1004.6    7 net   5 7net   15 net   7 net   100 gross 150 gross  See Section 1004.8  40 net   35 net             Institutional areas   Inpatient treatment areas   Dormitories   Educational     Classroom area     Shops and other vocational room areas   Exercise rooms   Group H‐5 Fabrication and manufacturing areas   Industrial areas   Information technology equipment facilities        Outpatient areas     Sleeping areas   Kitchens, commercial   Library     Reading rooms     Stack area   Locker rooms   Mall buildings—covered and open   Mercantile     Storage, stock, shipping areas   Parking garages   Residential   Skating rinks, swimming pools     Rink and pool     Decks   Stages and platforms   Warehouses   For SI: 1 square foot = 0.0929 m2.   a. Floor area in square feet per occupant.   50 gross     20 net   50 net   50 gross   200 gross   100 gross   300 gross    240 gross   100 gross   120 gross   200 gross     50 net   100 gross   50 gross  See Section 402.8.2   60 gross   300 gross   200 gross   200 gross     50 gross   15 gross   15 net   500 gross   1.  2.      1008.2.1 Illumination Level Under Normal Power. The means of egress illumination level shall be not less than 1  foot‐candle (11 lux) at the walking surface.   Exceptions: For auditoriums, theaters, concert or opera halls and similar assembly occupancies, the illumination at  the walking surface is permitted to be reduced during performances by one of the following methods provided  that the required illumination is automatically restored upon activation of a premises' fire alarm system:   Externally illuminated walking surfaces shall be permitted to be illuminated to not less than 0.2 foot‐candle  (2.15 lux).   Steps, landings and the sides of ramps shall be permitted to be marked with self‐luminous materials in  accordance with Sections 1025.2.1, 1025.2.2 and 1025.2.4 by systems listed in accordance with UL 1994; or  in accordance with Section 1025.6.   1009.3 Stairways. In order to be considered part of an accessible means of egress, a stairway between stories shall  have a clear width of 48 inches (1,219 mm) minimum between handrails and shall either incorporate an area of  refuge within an enlarged floor‐level landing or shall be accessed from an area of refuge complying with Section  1009.6 (Areas of Refuge). Exit access stairways that connect levels in the same story are not permitted as part of an  accessible means of egress.   Exceptions:  Page 10 of 19      Exit access stairways providing means of egress from mezzanines are permitted as part of an accessible  means of egress.   Except for a building governed by Section 403 (High‐Rise Buildings), the clear width of 48 inches (1,219 mm)  between handrails is not required in buildings equipped throughout with an automatic sprinkler system  installed in accordance with Section 903.3.1.1 (NFPA 13 sprinkler systems) or 903.3.1.2 (NFPA 13R sprinkler  systems).   Areas of refuge are not required at exit access stairways where two‐way communication is provided at the  elevator landing in accordance with Section 1009.8 (Two‐way communication).   Except for a building governed by Section 403 (High‐Rise Buildings), the areas of refuge are not required at  stairways in buildings equipped throughout with an automatic sprinkler system installed in accordance with  Section 903.3.1.1 (NFPA 13 sprinkler systems) or 903.3.1.2 (NFPA 13R sprinkler systems).   Areas of refuge are not required at stairways serving open parking garages.   Areas of refuge are not required for smoke‐protected assembly seating areas complying with Section  1030.6.2 (Smoke‐protected assembly seating).   Areas of refuge are not required for stairways accessed from a refuge area in conjunction with a horizontal  exit.   1010.1.2 Door Swing. Egress doors shall be of the pivoted or side‐hinged swinging type. Egress door types. Egress  doors shall be of the side‐hinged swinging door, pivoted door, or balanced door types.  Exceptions:  Private garages, office areas, factory and storage areas with an occupant load of 10 or less.   Group I‐3 occupancies used as a place of detention.   Critical or intensive care patient rooms within suites of health care facilities.    Doors within or serving a single dwelling unit in Groups R‐2 and R‐3.   In other than Group H occupancies, revolving doors complying with Section 1010.3.1 (Revolving doors).   In other than Group H‐1, H‐2, H‐3, and H‐4 occupancies, special purpose horizontal sliding, accordion or  folding door assemblies complying with Section 1010.3.3. (Special Purpose Horizontal Sliding, Accordion or  Folding Doors)  Power‐operated doors in accordance with Section 1010.3.2 (Power‐operated doors).   Doors serving a bathroom within an individual dwelling unit or sleeping unit in Group R‐1.   In other than Group H occupancies, manually operated horizontal sliding doors are permitted in a means of  egress from spaces with an occupant load of 10 or less.   1010.2.7 1010.2.6 Stairway Doors. Interior stairway means of egress doors shall be openable from both sides  without the use of a key or special knowledge or effort.   Exceptions:  Stairway discharge doors shall be openable from the egress side and shall only be locked from the opposite  side.   This section shall not apply to doors arranged in accordance with Section 403.5.3 (Stairway door operation).   In stairways serving two stories or greater in a building not classified as a high‐rise by Section 403 (High‐Rise  Buildings), doors are permitted to be locked from the side opposite the egress side, provided they are  openable from the egress side. The exit doors shall be capable of being unlocked simultaneously without  1.  2.  3.  4.  5.  6.  7.  1.  2.  3.  4.  5.  6.  7.  8.  9.  1.  2.  3.    Page 11 of 19      unlatching upon a signal from and approved fire department key switch. The key switch shall be located at  the exterior opening of the stair or at the main entrance to the building.   Stairway exit doors shall be openable from the egress side and shall only be locked from the opposite side in  Group B, F, M and S occupancies where the only interior access to the tenant space is from a single exit  stairway where permitted in Section 1006.3.4 (Single exits).   Stairway exit doors shall be openable from the egress side and shall only be locked from the opposite side in  Group R‐2 occupancies where the only interior access to the dwelling unit is from a single exit stairway  where permitted in Section 1006.3.4 (Single exits).   1010.3.3 Special Purpose Horizontal Sliding, Accordion or Folding Doors. In other than Group H‐1, H‐2, H3 and H‐ 4 occupancies, special purpose horizontal sliding, accordion or folding door assemblies permitted to be a  component of a means of egress in accordance with Exception 6 to Section 1010.1.2 (Door swing) shall comply  with all of the following criteria:   The doors shall be power operated and shall be capable of being operated manually in the event of power  failure.   The doors shall be openable by a simple method without special knowledge or effort from the egress side or  sides.   The force required to operate the door shall not exceed 30 pounds (133 N) to set the door in motion and 15  pounds (67 N) to close or open the door to the minimum required width.   The door shall be openable with a force not to exceed 15 pounds (67 N) when a force of 250 pounds (1100 N)  is applied perpendicular to the door adjacent to the operating device.   The door assembly shall comply with the applicable fire protection rating and, where rated, shall be self‐ closing or automatic closing by smoke detection in accordance with Section 716.2.6.6 (Smoke‐activated  doors), shall be installed in accordance with NFPA 80 and shall comply with Section 716 (Door closingOpening  Protectives).   The door assembly shall have an integrated standby power supply.   The door assembly power supply shall be electrically supervised.   The door shall open to the minimum required width within 10 seconds after activation of the operating  device.   1025.6 Active Egress Path Illumination System. An active egress path illumination system shall be in accordance  with Sections 1025.6.1 (Luminaires) through 1025.6.6.3 (Instrumentation and Annunciation). Designs complying  with this section are equivalent to the requirements in Sections 1025.1 (General) through 1025.5 (Illumination). I  The level of the egress illumination shall be in accordance with Section 1008 (Means of Egress Illumination).   1025.6.1 Luminaires. Luminaires shall be listed for emergency illumination and contain a lamp with an integral  battery, battery charger and manual test switch and comply with Article 700 of the Electrical Code. The unit  equipment shall be housed in a rated fixture for indoor wet locations. Luminaire batteries shall be listed for use as  a secondary power supply in accordance with UL 924. Luminaires shall not be equipped with an occupancy sensor.  Every luminaire shall have a test switch to confirm the lamp's availability for service when operating on primary or  emergency power.   Exception: The integral battery and battery charger is not required when luminaires are connected to a Stored  Energy Emergency Power Supply System (SEPSS) complying with Section 1025.6.5 (Stored Energy Emergency Power  Supply System).   1025.6.2 Primary and Secondary Electrical Power. A primary and secondary power source shall be provided for  each luminaire. Primary power shall be a dedicated electrical branch circuit supplied from utility power. Secondary  power shall be a branch circuit connected to an Emergency Power system complying with the International Fire  4.  5.  1.  2.  3.  4.  5.  6.  7.  8.    Page 12 of 19      Code Section 1203.2.15 (Means of Egress illumination). The primary and emergency source for each luminaire shall  be connected to a dedicated primary and emergency power branch circuit.   1025.6.3 Location. Luminaires for the active egress path illumination system shall be located at each intermediate  landing and stair landing within each interior exit stairway.   1025.6.4 Functional Test and Records. The luminaires shall be tested in accordance with Fire Code Section 1032.10  (Emergency Lighting Equipment Inspection and Testing) except that the frequency of activation tests shall be  weekly. Documentation records for the location of each luminaire and the results of the weekly activation and  annual power tests shall be in accordance with Fire Code Section 1032.10 (Emergency Lighting Equipment  Inspection and Testing). Records shall be available to the fire code official upon request. Operational testing and  maintenance reports produced by the SEPSS are permitted provided they comply with NFPA 110 Chapter 8.   1025.6.5 Lamp Failure. Luminaire lamps that do not operate because of a test or an incident shall be replaced. Any  battery that cannot operate a lamp for a minimum of 90 minutes shall be replaced.   1025.6.6 Stored Energy Emergency Power Supply System (SEPSS). When provided, the SEPSS with an integral  alternating current ‐ to ‐ direct current inverter shall comply with International Fire Code Section 1203.1.3  (Installation) and be listed in accordance with UL 924. The SEPSS shall be designed as Level 1 system in accordance  with NFPA 111.   The SEPSS shall be located in a room separated from the remainder of the building by a minimum 1‐hour fire‐ resistance rated construction and required opening protectives in accordance with this code. The design  temperature and humidity of the room housing the SEPSS shall be in accordance the manufacture installation  instructions.   SEPSS is prohibited inside a Fire Command Center.   1025.6.6.1 Load Carrying Capacity. Battery systems complying with NFPA 111 shall be used to supply the  emergency power to luminaires serving the active egress path illumination system. Batteries shall be rated for a  minimum 90‐minute discharge time and sized based on the total combined load of luminaires connected to the  SEPSS.   1025.6.6.2 Required SEPSS. In buildings where the highest occupied floor is less than or equal to 120 feet above  the lowest level of fire department access, one SEPSS shall be provided that complies with Section 1025.6.6 (Stored  Energy Emergency Power Supply System) for all required interior exit stairways. A SEPSS shall be provided for each  required interior exit stairway that serves floors greater than 120 feet above the lowest level of fire department  access.   1025.6.6.3 Instrumentation and Annunciation. Instrumentation and annunciation shall be in accordance with  NFPA 111. A remote annunciator displaying the status of the SEPSS shall be provided in the Fire Command Center.  The SEPSS and its annunciator shall display the following information and its function shall be identified in the Fire  Command Center:   Electrical load on utility power;   Electrical load on emergency power;   Output circuit breaker open;   Output overload or overcurrent;   High temperature;   1.  2.  3.  4.  5.  6.  7.  8.    Emergency conversion equipment is bypassed;   Low battery capacity; and   Any major or minor alarms prescribed by the SEPSS manufacturer.   1101.2  1102.1Design. Buildings and facilities shall be designed and constructed to be accessible in accordance  with this code and ICC A117.1.   Page 13 of 19      Exception: Components of projects designed in accordance with and regulated by the Architectural Barriers  Division of the Texas Department of Licensing and Regulation shall be deemed to be in compliance with the  requirements of this chapter, provided the scope of accessible features complies with the building code.   1108.6.1.2 Type B Units. In structures with three or more dwelling units or sleeping units intended to be occupied  as a residence, every dwelling unit and sleeping unit intended to be occupied as a residence shall be a Type B unit.   Exception: The number of Type B units is permitted to be reduced in accordance with Section 1108.7 (General  exceptions).   1108.6.2.2.2 Type B Units. Where there are three or more dwelling units or sleeping units intended to be occupied  as a residence in a single structure, every dwelling unit and sleeping unit intended to be occupied as a residence  shall be a Type B unit.   Exception: The number of Type B units is permitted to be reduced in accordance with Section 1108.7 (General  exceptions).   1108.6.2.3.2 Type B Units. Where there are three or more dwelling units or sleeping units intended to be occupied  as a residence in a single structure, every dwelling unit and every sleeping unit intended to be occupied as a  residence shall be a Type B unit.   Exception: The number of Type B units is permitted to be reduced in accordance with Section 1108.7 (General  exceptions).   1108.6.3 Group R‐3. In Group R‐3 occupancies where there are three or more dwelling units or sleeping units  intended to be occupied as a residence in a single structure, every dwelling unit and sleeping unit intended to be  occupied as a residence shall be a Type B unit. Bedrooms within congregate living facilities shall be counted as  sleeping units for the purpose of determining the number of units.   Exception: The number of Type B units is permitted to be reduced in accordance with Section 1108.7 (General  exceptions).   1108.6.4.2 Type B Units. In structures with three or more dwelling units or sleeping units intended to be occupied  as a residence, every dwelling unit and sleeping unit intended to be occupied as a residence shall be a Type B unit.   Exception: The number of Type B units is permitted to be reduced in accordance with Section 1108.7 (General  exceptions).   1203.1.12 (1) Required Air conditioning.         (A)   An owner shall:            (i)   provide, and maintain, in operating condition, refrigerated air equipment capable of maintaining a room temperature of at least 15 degrees cooler than the outside temperature, but in no event higher than 85° F. in each habitable room;            (ii)   maintain all fixed air conditioning systems, including air conditioning unit covers, panels, conduits, and disconnects, in operating condition, properly attached; and         (B) The required room temperatures shall be measured 3 feet (914 mm) above the floor near the center of the room and 2 feet (610 mm) inward from the center of each exterior wall .   SECTION 1204 Lighting   1204.1 General. Every space intended for human occupancy shall be provided with natural light by means of  exterior glazed openings in accordance with Section 1204.2 and shall be provided with artificial light in  accordance with Section 1204.3. Exterior glazed openings shall open directly onto a public way or onto a yard or  court in accordance with Section 1205.  Exceptions:     Page 14 of 19      1. Any room or space that is not within a dwelling unit or sleeping unit shall not be required to  provide natural light in accordance with Section 1204.2.  2. Any room or space with an area of 70 square feet, or less and is not a sleeping room shall not be  required to provide natural light in accordance with Section 1204.2.  3. Sleeping rooms within an existing dwelling unit shall not be required to provide natural light in  accordance with Section 1204.2 when alterations do not increase the total number of sleeping  rooms within the dwelling unit.  1204.2 Natural Light. The minimum net exterior glazed opening area shall be not less than 8 percent of the floor  area of the room(s) served.  1204.2.1 Adjoining Spaces. For the purpose of natural lighting, any room is permitted to be considered as a  portion of an adjoining room where the common wall provides an opening of not less than one‐tenth of the floor  area of the interior room or 24 square feet, whichever is greater. Openings required for natural light in common  walls can be windows and glazed doors.  Exception: Openings required for natural light shall be permitted to open into a sunroom with thermal isolation or  a patio cover where the common wall provides a glazed area of not less than one‐tenth of the floor area of the  interior room.    1204.2.2 Exterior Openings.  Exterior openings required by Section 1204.2 for natural light shall open directly onto  a public way, yard, or court, as set forth in Section 1205.  Exceptions:  1. Required exterior openings are permitted to open into a roofed porch where the porch  meets all of the following criteria:  1.1 Abuts a public way, yard, or court  1.2 Has a ceiling height of not less than 7 feet.  1.3 Has a longer side at least 65 percent open and unobstructed.  2. Skylights are not required to open directly onto a public way, yard, or court.          1204.3 Artificial light. Artificial light shall be provided that is adequate to provide an average illumination of 10  footcandles (107 lux) over the area of the room at a height of 30 inches (762 mm) above the floor level. 1204.4 Stairway illumination. Stairways within dwelling units and exterior stairways serving a dwelling unit shall  have an illumination level on tread runs of not less than 1 footcandle (11 lux). Stairways in other occupancies shall  be governed by Chapter 10.  1204.4.1 Controls. The control for activation of the required stairway lighting shall be in accordance with NFPA 70.    1204.5 Emergency egress lighting. The means of egress shall be illuminated in accordance with Section 1008.1.    1301.1 Energy Efficiency. Buildings shall be designed and constructed in accordance with the Energy Code.   1607.8.2 Fire Truck and Emergency Vehicles. Where a structure or portions of a structure are accessed and loaded  by fire department access vehicles and other similar emergency vehicles, the structure shall be designed as  specified in the Fire Code Section 503.2.6 (Bridges and elevated surfaces). 1607.8.2 Fire truck and emergency  Page 15 of 19      vehicles. Where a structure or portions of a structure are accessed by fire department vehicles and other similar  emergency vehicles, those portions of the structure subject to such loads shall be designed for the greater of the  following loads:  1. As specified in the International Fire Code Section 503.2.6 (Bridges and elevated surfaces)  2. The live loading specified in Section 1607.8.1.  Emergency vehicle loads need not be assumed to act concurrently with other uniform live loads.  SECTION 1612 FLOOD LOADS.  1612.1 General. A building or structure in a flood hazard area shall be designed and constructed according to  Article 3 (Flood Hazard Areas).   1612.2 Design and Construction. A building or structure in a flood hazard area shall be designed in accordance  with Article 3 (Flood Hazard Areas).   1612.3 Establishment of Flood Hazard Areas. Flood hazard areas are established in Article 3 (Flood Hazard Areas).   1612.4 Flood Hazard Documentation. Article 3 (Flood Hazard Areas) describes the documentation necessary for a  building or structure located in a flood hazard area.   SECTION 1811 EARTH RETENTION SYSTEMS  1811.1 Tieback Anchors and Soil and Rock Nails. Tieback anchors and soil and rock nails that are allowed in the  public right‐of‐way as components of earth retention systems as provided in Section 3202.1.4 (Earth retention  system components) shall comply with Sections 1811.1.1 (Depth of tiebacks anchors and soil and rock nails)  through 1811.1.3 (Length of tiebacks anchors and soil and rock nails).   1811.1.1 Depth of Tieback Anchors and Soil and Rock Nails. At the right‐of‐way line, tieback anchors and soil and  rock anchors shall be at least 6 feet (1,829 mm) below the elevation of the adjacent street curb.   1811.1.2 Separation Distance from Buried Utilities. Tieback anchors and soil and rock nails shall be below and at  least five feet (1,524 mm) away from the nearest outside surface of any existing or planned buried utility in the  public right‐of‐way.   1811.1.3 Length of Tieback Anchors and Soil and Rock Nails. Tieback anchors and soil and rock nails that extend  beyond the center of the public right‐of‐way are prohibited.   2108.4 ACI 530/ASCE 5/TMS402  Section 3.1.7.2.2. In Plane Bending. For masonry subjected to in‐plane loads, the modulus of rupture, f r , normal  and parallel to the bed joints shall be taken from Table 3.1.7.2.1. For grouted stack bond masonry, tension parallel  to the bed joints shall be assumed to be resisted only by the continuous horizontal grout section.   2901.1 Scope. The provisions of this chapter and the Plumbing Code shall govern the design, construction, erection  and installation of plumbing components, appliances, equipmentequipment, and systems used in buildings and  structures covered by this code.   Table 2902.1, Column Header 4. Reference to Section 424.2 of the International Plumbing Code shall be replaced  with the following: In each bathroom or toilet room, urinals shall not be substituted for more than 67 percent of  the required water closets in assembly and educational occupancies. Urinals shall not be substituted for more than  50 percent of the required water closets in all other occupancies.   Table 2902.1, Column Header 7. Reference to Section 410 of the International Plumbing Code shall be replaced  with Section 415 of the Plumbing Code.   2902.2 Separate Facilities. Where plumbing fixtures are required, separate facilities shall be provided for each sex.   Page 16 of 19          Exceptions:  Separate facilities shall not be required for dwelling units and sleeping units.   Separate facilities shall not be required in structures or tenant spaces with a total occupant load, including  both employees and customers, of 15 or fewer.   Separate facilities shall not be required in mercantile occupancies in which the maximum occupant load is  100 or fewer.   Separate facilities shall not be required in business occupancies when the maximum occupant load is 50 or  fewer.   Separate facilities shall not be required to be designated by sex where single‐user toilets rooms are provided  in accordance with Section 2902.1.2.   Separate facilities shall not be required where rooms having both water closets and lavatory fixtures are  designed for use by both sexes and privacy for water closets are installed in accordance with Section 405.3.4  of the International Plumbing Code. Urinals shall be located in an area visually separated from the remainder  of the facility or each urinal that is provided shall be located in a stall.   2902.6 Small Occupancies. Drinking fountains shall not be required for an occupant load of 30 or fewer. For a  business or a mercantile occupancy where the occupancy load is 30 or fewer, service sinks shall not be required.   3103.5 Portable Classrooms. Portable classroom buildings may be moved into or within this jurisdiction or within a  public school district without conforming to the adopted Energy Code.   3201.1 Encroachments Scope. The provisions of this chapter shall govern the encroachment of structures into the  public right‐of‐way, including components of earth retention systems used to facilitate below‐grade construction  of a building or structure.   3202.1 Encroachments Below Grade. Encroachments below grade shall comply with Sections 3202.1.1 (Structural  support) through 3202.1.4 (Earth retention system components).   3202.1.4 Earth Retention System Components. Components of earth retention systems that are required for  structural support of a building or structure are prohibited in the public right‐of‐way. Components of earth  retention systems that are needed only during construction of the below‐grade portion of a building or structure  are subject to the following conditions:   Approval of the Director of the Public Works Department is required before construction of earth retention  system components in public right‐of‐way commences.   All components of an earth retention system are prohibited in the public right‐of‐way except for (1) tieback  anchors that are part of a soldier pile and lagging system; (2) tieback anchors that are part of a diaphragm or  slurry wall system; (3) tieback anchors that are part of a sheet pile wall system; (4) tieback anchors that are  part of a secant wall system; and (5) soil or rock nails that are part of a nail wall.   Tieback anchors or soil or rock nails that are necessary as functional components of the earth retention  system for longer than 12 months are prohibited in the public right‐of‐way.   Tieback anchors and soil and rock nails allowed in the public right‐of‐way shall be designed according to the  criteria in Section 1811 (Earth Retention Systems).   3202.3.4 Pedestrian Walkways. An approved encroachment agreement that complies with Chapter 14‐11 (Use of  Right‐of‐Way) is required prior to the installation of a pedestrian walkway and all associated utilities over a public  right‐of‐way. The vertical clearance from the public right‐of‐way to the lowest part of a pedestrian walkway shall  be not less than 16 feet 6 inches over roadway and alley subject to truck traffic, and not less than 15 feet over  other areas in the right‐of‐way.   1.  2.  3.  4.  5.  6.  1.  2.  3.  4.      Page 17 of 19            ARTICLE 10. EXISTING BUILDING CODE  § 25‐12‐231 INTERNATIONAL EXISTING BUILDING CODE.  (A)  The International Existing Building Code, 20241 Edition, published by the International Code Council ("20241  International Existing Building Code") is adopted and incorporated by reference into this section with the  deletions in Subsection (B) and the amendments in Section 25‐12‐233 (Local Amendments to the  International Existing Building Code).   (B)  The following provisions of the 20241 International Existing Building Code are deleted.   105.1.1   105.5   106.2.6   111.3           112 plus  subsections    103 plus  subsections   105.2    (C)  The city clerk shall file a copy of the 20241 International Existing Building Code with the official ordinances of  the City.   § 25‐12‐232 CITATIONS TO THE EXISTING BUILDING CODE.  In the City Code, "Existing Building Code" means the 20241 International Existing Building Code adopted in  Section 25‐12‐231 (International Existing Building Code) as amended by Section 25‐12‐233 (Local Amendments to  the International Existing Building Code). In this article, "this code" means the Existing Building Code.   § 25‐12‐233 LOCAL AMENDMENTS TO THE INTERNATIONAL EXISTING BUILDING CODE.  Each provision in this section is a substitute for the identically numbered provision deleted in Section 25‐12‐231 (B)  (International Existing Building Code) or is an addition to the 20241 International Existing Building Code.   SECTION 103 Code Compliance AgencyBUILDING OFFICIAL.  [A] 103.1 Authority. The building official administers, enforces, and interprets this code. The building official may  designate one or more deputy building officials.   105.1.1 Annual permit. Instead of an individual permit for each alteration to an already approved electrical, gas,  mechanical or plumbing installation, and minor building alterations and repairs, the building official is authorized  to issue an annual permit upon application therefor to any person, firm or corporation regularly employing one or  more qualified trade persons in the building, structure or on the premises owned or operated by the applicant for  the permit. The facility shall maintain records on all work performed under the annual permit in accordance with  Section 105.1.2 (Annual Permit Records).   105.1.1.1 Authorized Scope of Work. See Building Criteria Manual, Section 1.1.2 (Building Inspection Processes) for  authorized work under the annual permit.   105.5 Time Limits. Article 13 (Administration of Technical Codes) of this chapter establishes permit application  time limits and requirements applicable to permit expiration and reactivation, including a review fee for expired  permits.   106.2.6 Site plan. The construction documents submitted with the application for permit shall be accompanied by  a site plan showing to scale the size and location of new construction and existing structures on the site, distances  from lot lines, the established street grades and the proposed finished grades and, as applicable, flood hazard  areas, floodways, and design flood elevations; and it shall be drawn in accordance with an accurate boundary line  Page 18 of 19    survey. In the case of demolition, the site plan shall show construction to be demolished and the location and size  of existing structures and construction that are to remain on the site or plot. For a building or structure involving  below‐grade construction, the site plan shall show the location of proposed earth retention system components  allowed under Section 3202.1.4 (Earth Retention System Components) of the Building Code. The building official is  authorized to waive or modify the requirement of the site plan when the application for permit is for alteration,  repair or change of occupancy when otherwise warranted.   111.3 Authority to Disconnect Service Utilities. The building official shall have the authority to authorize  disconnection of utility service to the building, structure or system regulated by this code and the referenced codes  and standards in case of emergency where necessary to eliminate an immediate hazard to life or property, where  one or more circumstances listed in Section 15‐9‐101(A)(2) (Basis for Termination of Service) exist, or where such  utility connection has been made without the approval required by Section 112.1 or 112.2. The building official  shall provide notice in accordance with Section 15‐9‐106 (Notice of Service Disconnection) of the decision to  disconnect prior to taking such action. If not notified prior to disconnecting, the owner or the owner's authorized  agent or occupant of the building, structure or service system shall be notified in writing, as soon as practical  thereafter in accordance with Section 15‐9‐106 (Notice of Service Disconnection).   SECTION 112 BUILDING AND FIRE CODE BOARD OF APPEALS. The Building and Fire Code Board of Appeals shall  comply with Chapter 2‐1 (Boards and Commissions).