Planning CommissionJuly 23, 2024

21 SPC-2023-0110C - Stassney Park; District 2 Staff Presentation — original pdf

Backup
Thumbnail of the first page of the PDF
Page 1 of 15 pages

STASSNEY PARK 6200 E STASSNEY LANE SPC-2023-0110C Mike McDougal Environmental Policy Program Manager Development Services Department STASSNEY PARK 6200 E Stassney Ln North NTS PROPERTY DATA • Williamson Creek Watershed • Suburban Watershed Classification, Desired Development Zone • Not Located over Edwards Aquifer Recharge Zone • Austin Full Purpose • Council District 2 EXISTING CONDITIONS EXISTING CONDITIONS - CONTINUED EXISTING CONDITIONS - CONTINUED EXISTING CONDITIONS - CONTINUED CWQZ Slopes >15% North NTS VARIANCES REQUESTED 1. Request to vary LDC 25-8-341 to allow cut up to 24 feet 2. Request to vary LDC 25-8-342 to allow fill up to 23 feet 3. Request to vary LDC 25-8-301 to allow driveway construction on a gradient in excess of 15% NTS VARIANCES REQUESTED - CONTINUED 1. Request to vary LDC 25-8-341 to allow cut up to 24 feet 2. Request to vary LDC 25-8-342 to allow fill up to 23 feet 3. Request to vary LDC 25-8-301 to allow driveway construction on a gradient in excess of 15% NTS GRADING VARIANCE FINDINGS IN SUMMARY • Variances for grading have been granted for similar projects. • Grading is a design decision but the project provides greater environmental protection with increased landscaping, increased creek restoration, and increased Critical Water Quality Zone restoration. • The project does not create a significant probability of harmful environmental consequences. • The variance will result in water quality that is at least equal to the water quality achievable without the variance. SLOPES VARIANCE FINDINGS IN SUMMARY • Variances for driveway construction on slopes have been granted for sites with similar constraints. • Driveway construction on slopes is necessary to allow for a reasonable use of the property and is not a design decision. • The project does not create a significant probability of harmful environmental consequences. • The variance will result in water quality that is at least equal to the water quality achievable without the variance. FINDINGS OF FACT PER LDC 25-8-41 • City Staff determined the Findings of Fact have been met per LDC 25-8-41 for the requested variances • Consequently, City Staff recommended approval of the variances to the Environmental Commission (6/5/2024 Environmental Commission meeting) with variance conditions STAFF VARIANCE CONDITIONS ENVIRONMENTAL COMMISSION VOTE The Environmental Commission may accept or reject City Staff’s recommendation APPLICANT PRESENTATION