B-10 C8J-2020-0148 - Prospect Park Preliminary Plan; District 2pdf.pdf — original pdf
Backup
SUBDIVISION REVIEW SHEET CASE NO.: C8J-2020-0148 P.C. DATE: July 27, 2021 SUBDIVISION NAME: Prospect Park Preliminary Plan AREA: 234.52 acres LOT(S): 806 OWNER/APPLICANT: Carma Easton, LLC (AJ Zorn) AGENT: Carlson, Brigance, and Doering,Inc (Brett Pasquarella) ADDRESS OF SUBDIVISION: Apogee and Ausblick GRIDS: K12 COUNTY: Travis WATERSHED: North Fork Dry Creek JURISDICTION: Limited Purpose EXISTING ZONING: Planned Unit Development (PUD) MUD PLAN: Pilot Knob MUD DISTRICT: 2 PROPOSED LAND USE: Residential- Single Family; greenbelt, landscape/ drainage easement lots, and public ROW VARIANCES: None SIDEWALKS: Sidewalks will be provided along all internal streets and the boundary street. DEPARTMENT COMMENTS: The request is for the approval of the Prospect Park Preliminary Plan. The plan is comprised of 806 lots on 234.52 acres, proposing 784 residential lots, 17 greenbelt/park lots and 5 other lots for landscape/drainage easement, and approximately 37,436 linear feet of right-of- way/streets. Sidewalks are proposed on all streets. The proposed lots comply with the PUD zoning requirements for use and lot size. Parkland will be in compliance with the PUD. Water and wastewater will be provided by the City of Austin. This plat is subject to HB3167. Staff recommends approval of the plan, subject to the conditions listed in the attached comment report (Exhibit C). After the conditions are met, the plan will comply with the City of Austin Land Development Code, Chapter 30-2-84(B). Some of the conditions include updating plan notes, show environmental setbacks, showing the use for 1 lot, verification of street names/street table, etc. These are administrative actions that require no discretionary review. An application that has been approved with conditions may be updated to address those conditions until the application expires and the plan does not need to be heard before the Commission/Court again. The plat has also been scheduled to be approved with conditions by the Travis County Commissioners Court at the July 27, 2021 meeting. STAFF RECOMMENDATION: Staff recommends approval of the plan, subject to the conditions listed in the attached comment report dated July 21, 2021, and attached as Exhibit C. CASE MANAGER: Sue Welch, Travis County Single Office PHONE: 512-854-7637 Email address: Sue.Welch@traviscountytx.gov EXHIBITS: A: Location Map; B: Proposed Plan; C: Prospect Park Comment report dated July 21, 2021 1 of 13B-10CITY OF AUSTIN – TRAVIS COUNTY – SINGLE SUBDIVISION OFFICE SUBDIVISION APPLICATION – MASTER COMMENT REPORT C8J-2020-0148 00 Sue Welch UPDATE: U0 PHONE #: 512-854-7637 Prospect Park Preliminary Plan 7931-1/2 APOGEE BLVD CASE NUMBER: REVISION #: CASE MANAGER: PROJECT NAME: LOCATION: SUBMITTAL DATE: June 28, 2021 REPORT DUE DATE: July 26, 2021 FINAL REPORT DATE: July 21, 2021 STAFF REPORT: This report includes all staff comments received to date concerning your most recent subdivision application submittal. The comments may include requirements, recommendations, or information. The requirements in this report must be addressed by an updated submittal. The subdivision application will be approved when all requirements from each review discipline have been addressed. If you have any questions, concerns or if you require additional information about this report, please contact your case manager at the phone number listed above or by using the contact information listed for each reviewer in this report. Any change to the plan/plat shall not cause noncompliance with any applicable code or criteria. In addition, any change to the plat may trigger new comments. UPDATE DEADLINE (LDC 30-2-56; 30-2-82): All comments must be addressed by filing an updated submittal prior to the update deadline of December 31, 2021. Otherwise, the application will expire. If this date falls on a weekend or City of Austin holiday, the next City of Austin workday will be the deadline. Extension of Review Period, Extension of Update Deadline and Tolling of Application Period do not apply to applications for preliminary plan, plat or subdivision construction plans (LDC). UPDATE SUBMITTAL INSTRUCTIONS (LDC 30-1-113): 1. Applicants must make an appointment with Intake Staff (974-1770) in order to submit an update. 2. Your update must include the following items: a. This report b. The revised plat/plan in pdf format c. A letter that addresses each comment in the master comment report 3. Updates must be submitted on an approved submittal date, between the hours of 8:30 am and 4:00 pm. Refer to the submittal calendar for a list of approved submittal dates. REVIEWERS: Planner 1: Addison Ptomey Travis Co. Subdivision: Sue Welch Travis Co. Transportation: Christine Connor Environmental : Pamela Abee-Taulli Transportation Planning: Martin Laws Water Quality: David Marquez Wetlands Biologist: Ana Gonzalez Zoning Land Development: Amy Combs 2 of 13B-10 Environmental Review - Pamela Abee-Taulli - 512-974-1879 EV 1 Provide an exhibit showing the additional 4 acres and any other changes between the layout approved in the Project Assessment and the layout proposed with this preliminary plan. Flood Plain Review - Katina Bohrer - 512-974-3558 Site is located in North Fork Dry watershed and is located in the headwaters of two tributaries which do not have detailed study areas. Tribs are partially FEMA zone A (unstudied) and completely unstudied but within the CWQZ which indicates likelihood of more than 64 acres of drainage. Prelim plan shows 25 and 100-yr floodplains, easement, FEMA floodplains and an engineering report is provided which indicates that Atlas 14 was used to determine the extent of the floodplain. Associated modeling was provided and has been uploaded to our network. Workmaps are included in an attachment to the report. Floodplain Review of associated Project Assessment was completed on 5/6/2021. Applicant indicated that proposed crossings are to be built in the future, but not with the Prelim/Plat (obviously). FP review for Prelim/Plat was deemed to be complete, but the bolded information below needs to be checked at SubConst Stage: Modeling for proposed crossings shows localized rises in WSEL. Applicant has confirmed that all off site rises will be contained to drainage easement to be obtained as part of subdivision construction plan (or dedicated prior to Sub Const as part of the platting process for the adjacent properties). This process is acceptable as the roadway crossings may change up until the Sub Const stage which may affect the floodplain. FYI: Floodplain is shown to be contained to a delineated drainage easement in compliance with code and criteria. It does not, however, appear there is any information provided for bearings/metes & bounds for the easement itself. It is my understanding that a delineated easement to be dedicated by plat still needs to have enough information to be able to locate the easement on the property (measurements, bearings from known points, etc.). For questions related to easement delineation requirements on plats, please talk to the case manager. As this is a prelim plan, I believe that the easement delineation as shown is sufficient, but realize it may not be sufficient for platting. Transportation Planning - Martin Laws - 512-974-6351 TR1. TR2. On preliminary plans, provide a table specifying street classifications, right-of-way width, pavement width, cross-section (shoulders, curb and gutter, or ribbon curb) and sidewalk location (if applicable) in accordance with the TCM, Sec. 1.3.0. On preliminary plans, provide a plat note stating that streets will be constructed to City of Austin standards and dedicated as public right-of-way with the final plat. LDC 25-6-171(a). AW Utility Development Services - Bradley Barron - 512-972-0078 AW1. Per Utility Criteria Manual Section 2, §15-9, §30-2, §25-5, §25-9, and the Uniform Plumbing Code: The landowner intends to serve each lot with City of Austin water and wastewater utilities in accordance with approved Service Extension Requests 4905 (W) and 4906 (WW). Each lot must have a separate water and wastewater utility connection and no existing or proposed plumbing may cross lot lines. The landowner, at own expense, will be responsible for providing the water 3 of 13B-10and wastewater utility improvements, offsite main extensions, system upgrades, utility relocations and or abandonments to serve each lot. FYI. The landowner must pay the tap and impact fee once the landowner makes an application for a City of Austin water and wastewater utility tap permit. Water Quality Review - David Marquez - 512-974-3389 WQ1 Preliminary note 12 should be removed as per LDC 30-5-211. WQ2 Demonstrate or discuss how all impervious cover will be treated as per LDC 30-5-211. Areas in question are areas that drain away from the streets such as block M lot 35-44 or block a lots 1-10. WQ3 For the storm drain system that starts at Apogee, verify that there is enough cover and fall in the storm drain system to the point of the pond so that the system meet DCM section 5 standards. On Pallas for instance, inlets collect at approximately 590 to begin the storm drain. Water is in the pipe for over 3,000’ and discharges into pond b that appears to discharge into a pond that is in the 540’s elevation. This seems possible but the slopes are fairly low in that stretch and variances for minimum velocities would want to be avoided. Possible redesign to add ponds if flows cannot get to the pond may be needed if flows cannot reach the pond so it should be looked into now prior to locking in lot locations. WQ4 An erosion hazard zone analysis should be completed for the greenbelt trail if trails are to be added. Per DCM appendix E and LDC 30-5-261. Wetlands Biologist Review - Ana Gonzalez - 512-974-2929 WETL 1. Update 0 This project does not comply with Critical Environmental Feature protection 4 of 13B-10requirements. [LDC 25-8-281 or LDC 30-5-281; LDC 25-8-282 or LDC 30-5-282; ECM 1.10] and compliance with PUD Ordinance 20161110-032 Part 12 Section G-9 cannot be established. Additional information: {CEFs on site not shown; see map below} WETL 2. Update 0 This project does not comply with Critical Environmental Feature protection requirements. [LDC 25-8-281 or LDC 30-5-281; LDC 25-8-282 or LDC 30-5-282; ECM 1.10] and compliance with PUD Ordinance 20161110-032 Part 12 Section G-9 cannot be established. Additional information: {standard CEF buffers not shown, standard CEF buffer not shown on preliminary notes – please add}. WETL 3. Update 0 This project does not comply with Critical Environmental Feature protection requirements. [LDC 25-8-281 or LDC 30-5-281; LDC 25-8-282 or LDC 30-5-282; ECM 1.10] and compliance with PUD Ordinance 20161110-032 Part 12 Section G-9 cannot be established. Additional information: {if preliminary is proposing reduction in standard CEF buffers or destruction of CEFs on site, proposed CEF buffer transfer needs to be documented in exhibit M}. Zoning Land Development Review - Amy Combs - (512) 974-2786 ZR1. Please clarify what is meant by “single family lots” on the plan and application. Is it meant that the proposed lots would either be “Residential Detached (Yard House and Others)”, or “Zero Lot Line Detached (Yard House)” as described in Ordinance No. 20151217-080, Exhibit G? ZR2. Please replace all of the dark grey hatching representing the access easements on all of the flag lots on the face of the plan with a lighter hatching as shown on Sheet 2 of the plan in the “typical joint use easement” detail - all lot lines (including flag lot lines) need to be clearly shown on the face of the plan and the eventual final plat. All easement lines (existing and proposed) must be broken and a lighter weight than the lot lines. (30-1-113) ZR3. Please annotate each easement with the holder of the easement and recording information. (30-1- 113) use. (30-1-113) ZR4. On Sheet 4 Block A -What is the intended use of Lot 67? Please label this lot with the intended ZR5. Please ensure that there is at least one public right of way or public assess easement connecting neighborhoods to trails. The easement should be a minimum of 15 feet in width (Ordinance No. 20151217-080, Page D-5) ZR6. Please ensure that the following requirement is met: “A residential block that is more than 900 feet in length must be transected by a sidewalk not less than 300 feet wide, comply with city standards, and be located within an easement or ROW that is not less than 15 feet wide” (Exhibit S, Page S-2, Ordinance No. 20151217-080) Travis Co. Subdivision Review - Sue Welch - 512-854-7637 1. Please verify that Addressing has reserved the street names for the final layout. Please check if they require this note: “Addresses for residential flag lots must be displayed at their closest point of access to a public street.” 25-4-175/30-2-113 2. Please contact this reviewer once all comments are cleared. 5 of 13B-10Travis Co. Transportation Review - Christine Connor - 512-854-7215 1) Modify the Typical Joint Access Easement Detail & Typical Quad Driveway to show a 56’ right-of- Travis Co. Drainage Construction Review - Christine Connor - 512-854-7215 Informational – The drainage for each individual section should operate independently. An in-depth review for each section will be conducted with the plat submittal. way. END OF REPORT 6 of 13B-107 of 13B-108 of 13B-109 of 13B-1010 of 13B-1011 of 13B-1012 of 13B-10Legend Jurisdiction FULL PURPOSE LIMITED PURPOSE OTHER CITY LIMITS OTHER CITIES ETJ TCAD Parcels Jurisdiction FULL PURPOSE LIMITED PURPOSE EXTRATERRITORIAL JURISDICTION 2 MILE ETJ AGRICULTURAL AGREEMENT EXTRATERRITORIAL JURISDICTION 2 MILE ETJ AGRICULTURAL AGREEMENT OTHER CITY LIMITS OTHER CITIES ETJ Site Location 0.3 7-12-21 NAD_1983_StatePlane_Texas_Central_FIPS_4203_Feet 0 0.15 0.3 Miles This product is for informational purposes and may not have been prepared for or be suitable for legal, engineering, or surveying purposes. It does not represent an on-the-ground survey. This product has been produced by the City of Austin for the sole purpose of geographic reference. No warranty is made by the City of Austin regarding specific accuracy or completeness. 1: 9,600 Notes Prospect Park Preliminary Plan Location Map 13 of 13B-10