Planning CommissionMay 25, 2021

B-17 (SPC-2020-0285D - Pharr Tennis Center Renovation).pdf — original pdf

Backup
Thumbnail of the first page of the PDF
Page 1 of 4 pages

PLANNING COMMISSION SITE PLAN COMMISSION APPROVAL REVIEW SHEET Boggy Creek PC DATE: 5/25/2021 4201 Brookview Road SPC-2020-0285D City of Austin Parks and Recreation Department Jose I. Guerra, Inc. (Glenn Frey, PE) 512-445-2090 CASE NUMBER: PROJECT NAME: Pharr Tennis Center Renovation ADDRESS: APPLICANT: AGENT: CASE MANAGER: Jeremy Siltala (512) 974-2945 or jeremy.siltala@austintexas.gov WATERSHED: APPLICATION REQUEST: Sites zoned Public (P) with limits of construction greater than one acre in size are a Conditional Use that require Land Use Commission approval according to Land Development Code section 25-2-625. PROJECT DESCRIPTION: The applicant proposes renovations to existing tennis courts with associated improvements. STAFF RECOMMENDATION: Staff recommends approval of the conditional use permit request. The site plan will comply with all other requirements of the Land Development Code prior to its release. PROJECT INFORMATION: SITE AREA ZONING LAND USE IMPERVIOUS COVER BUILDING HEIGHT VEHICULAR ACCESS NEIGHBORHOOD ORGANIZATIONS: Austin Independent School District Austin Lost and Found Pets Austin Neighborhoods Council Cherrywood Neighborhood Assn. Del Valle Community Coalition Friends of Austin Neighborhoods Friends of Patterson Park Homeless Neighborhood Association 8.4 acres Public (P) Parks and Recreation Services (General) 1.7 AC or 20% 15 FT, 1 story Brookview Road Neighborhood Empowerment Foundation Neighbors United for Progress Preservation Austin SELTexas Schieffer/Willowbrook Sierra Club, Austin Regional Group Upper Boggy Creek Neighborhood Planning Team 1 of 4B-17 Page 2 SPC-2020-0285D CONDITIONAL USE PERMIT REVIEW AND EVALUATION CRITERIA The following evaluation is included to provide staff position on each point of the conditional use permit criteria. Section 25-5-145 of the Land Development Code states: “The Commission shall determine whether the proposed development or use of a conditional use site plan complies with the requirements of this section. Pharr Tennis Center Renovation 1. Comply with the requirements of this title; Staff response: This application complies with the requirements of this A conditional use site plan must: title. 2. Comply with the objectives and purposes of the zoning district; Staff response: This application complies with the objectives and purposes of the zoning district. 3. Have building height, bulk, scale, setback, open space, landscaping, drainage, access, traffic circulation, and use that are compatible with the use of an abutting site; Staff response: This application is compatible with the abutting sites. 4. Provide adequate and convenient off-street parking and loading facilities; Staff response: Adequate parking and loading facilities have been provided. 5. Reasonably protect persons and property from erosion, flood, fire, noises, glare, and similar adverse effects; Staff response: The proposed project does not contribute to any of these adverse effects. A conditional use site plan may not: 1. More adversely affect an adjoining site than would a permitted use; Staff response: The site plan will conform with all regulations and standards established by the Land Development Code prior to its release. 2. Adversely affect the safety or convenience of vehicular or pedestrian circulation, including reasonably anticipated traffic and uses in the area; Staff response: The project is not anticipated to have any detriment to safety or convenience. 3. Adversely affect an adjacent property or traffic control through the location, lighting, or type of signs; Staff response: No signage or lighting is proposed that would affect adjacent properties or traffic control. COMMISSION ACTION: The Commission may either; approve, approve with conditions or deny the conditional use site plan permit. To make a determination required for approval under Section 25-5-145 (Evaluation of Conditional Use Site Plan), the Land Use Commission may require that a conditional use site plan comply with a condition of approval that includes a requirement for: 1) A special yard, open space, buffer, fence, wall, or screen; 2) Landscaping or erosion; 3) A street improvement or dedication, vehicular ingress and egress, or traffic circulation; 4) Signs; 5) Characteristics of operation, including hours; 6) A development schedule; or 7) Other measures that the Land Use Commission determines are required for compatibility with surrounding uses or the preservation of public health, safety, or welfare. 2 of 4B-17 W I L S H I R E B L V D LOC LOC LOC C O L TENNIS COURTS L O C B R O O K V I L O C E W R O A D L O C TENNIS COURTS L O C L O C L O C PATTERSON PARK C O L EXISTING PRO SHOP C O L C O L TENNIS COURTS C O L LIMITS OF CONSTRUCTION L O C L O C L O C A I R P O R T B L V D PROPERTY BOUNDARY CITY OF AUSTIN VOL. 668, PG. 396 DRTCT TCAD 0217130303 4100 AIRPORT BOULEVARD S C HIE FF E R A V E 1701 Directors Blvd Suite 250 Austin Texas 78744 512 861 9600 kirksey.com These drawings have been prepared as one coordinated set of drawings and are complimentary. What is required by one drawing is required by all of the drawings, even if a detail or component part is not identified on every sheet. Any user ’s reliance on a single or select few sheet(s) of the drawings without consideration for the information included in the entire set of drawings will be at the user ’s sole risk and shall not form the basis for a request for additional compensation or time. NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION Glenn Frey, PE Texas Registration #123856 05/20/2020 DATE ISSUE G 02/16/2021 ISSUE FOR PERMIT & CONSTRUCTION 230 LF OF 5' WIDE PUBLIC CONCRETE SIDEWALK RE: 432S-1/C8.02 599 8 " W W WWMH TOP=600.53 FL IN(S)=592.03 FL OUT(W)=591.93 601 WW 8 " W W 1567 1567 3 0 6 W I L S H I R E B O U L E V A R D ( 6 0 ' R . O . W . ) IC TRV 42 N=10081749.53 E=3124345.91 5/8" IRON ROD W/MWM CAP PUBLIC TYPE 1 CURB RAMP WITH DETECTABLE WARNING PAVERS 613 613 RE: 432S-1/C8.02 5 9 9 615 615 525 525 1700 1700 1699 1699 EXISTING WATER METER TO REMAIN 1696 1696 1694 1694 W 1702 1702 6 0 2 W W W 1693 1693 ICICICIC 604 526 526 W W 527 527 523 523 528 528 W W 529 529 W W W 616 616 TENNIS COURT STRIPING AND COURT ACCESSORIES RE: LANDSCAPE 1 SITE & TENNIS COURT LIGHTING. RE: ELECTRICAL 1 5 . 7 ' W 2 7 5 . 3 0 ' S 8 2 ° 1 4 ' 5 4 . 3 6 " W 1695 1695 2183 2183 5 . 0 ' 2182 2182 2181 2181 2184 2184 2180 2180 2185 2185 605 CONNECT NEW PUBLIC SIDEWALK TO EXISTING PUBLIC SIDEWALK IRRIGATION LINE RE: IRRIGATION 3 4 O E E O E S T M TRV 41 N=10081781.89 E=3124681.79 S "X" CUT T M C E 605 TC E O E S T M GENERAL NOTES: 1. EXISTING UTILITIES INDICATED ARE PROVIDED BY SURVEY AND FROM PREVIOUS DRAWINGS. CONTRACTOR TO FIELD VERIFY PRIOR TO ANY EXCAVATIONS. 2. CONTRACTOR SHALL INSTALL EROSION/SEDIMENT CONTROLS AND TREE/NATURAL PROTECTIVE FENCING PRIOR TO ANY SITE PREPARATION WORK (CLEARING, GRUBBING, EXCAVATION, DEMOLITION, ETC.) 3. SEE LANDSCAPE DRAWINGS FOR TREE MITIGATION CALCULATIONS AND FENCING DETAILS. 6 1 0 TENNIS COURT NOTES: 0 6 5 REFER TO LANDSCAPE DRAWINGS FOR TENNIS COURT STRIPING, NETTING, AND FENCING DETAILS. GATE NOTES: REFER TO LANDSCAPE KEY PLAN FOR GATE NUMBERS. EXISTING UTILITY POLE TO REMAIN S T M O E S T M 5336 5336 O E S T M 5339 5339 5340 5340 S T M O E E 5341 5341 5337 5337 4 0 6 10' CHAIN LINK FENCE AT PERIMETER OF TENNIS COURTS, TYP. 6 0 3 6 0 4 EXISTING PUBLIC ±6' SIDEWALK TO REMAIN B ( O A 1 I 6 U R 0 ' R L P E O . V R O . A T W R D . ) EXISTING UTILITY POLE TO REMAIN DOUBLE GATE, 6' WIDE FOR MAINTENANCE CONCRETE PAD FOR TRASH AND RECYCLE BINS, TRASH AND RECYCLE BINS OFOI PROPOSED 3' GATED COURT ACCESS 605 1697 1697 W 2 3' GATED COURT ACCESS 240' X 120' TENNIS COURT RE: STRUCTURAL 5 9 8 6 0 0 W W W W B R O O K V R O A D I ( 3 0 ' R . O . W . ) E W CITY OF AUSTIN VOL. 668, PG. 396 DRTCT TCAD 0217130301 1714-1/2 SCHIEFFER AVENUE 620 620 149 149 W W W W W W 601 634 634 RESOLUTION 520501-2 DEDICATED FOR PUBLIC PARK AND ROAD PURPOSES (10.327 ACRES) ORNAMENTAL FENCE RE: LANDSCAPE DRAWINGS W TREE WELL RETAINING WALL RE: 1/S3.02 W W W 796 796 797 797 798 798 SITE DATA TABLES O E O E E 5343 5343 EXISTING OVERHEAD UTILITY TO REMAIN AND BE PROTECTED 120' X 120' TENNIS COURT RE: STRUCTURAL O E PLANTING BED EXISTING UTILITY POLE TO REMAIN O E L = 7 1 2 . 6 ' , R = 1 8 2 9 O . 8 E 0 ' EXISTING UTILITY POLE GUY WIRES TO REMAIN S T M 5342 5342 S T M 1748 1748 S T M S T M 2 0 6 S T M S T M ORNAMENTAL FENCE. RE: LANDSCAPE DRAWINGS O E CONNECT PRIVATE 5' SIDEWALK WITH EXISTING PUBLIC SIDEWALK 4' MAN GATE WITH KNOX BOX FOR FIRE DEPARTMENT ACCESS EXISTING UTILITY POLES, ELECTRICAL METERS, CABINETS, AND RACKS TO REMAIN AND BE PROTECTED C E 5003 5003 2172 2171 2170 RD 4 5 . 5 ' EXISTING PRO SHOP FF 601.20 4 2 . 4 ' 1081 1079 1080 S T EXISTING PRO SHOP M AIPP PROJECT S T M O E 4' WIDE DECOMPOSED GRANITE PATH RE: LANDSCAPE E 6 0 1 S T M DRINKING FOUNTAIN RE: UTILITY PLAN 7 S T M 3' GATED COURT ACCESS 8 T S PROPOSED 4' ACCESSIBLE SIDEWALK M W IC EXISTING DRINKING FOUNTAIN TO REMAIN RE: UTILITY PLAN 5 6 10' HIGH CHAIN LINK FENCE AT PERIMETER OF TENNIS COURTS, TYP. IRRIGATION LINE RE: IRRIGATION ±3.5' HIGH GRASSED BERM 824 824 465 465 W 5' ACCESSIBLE SIDEWALK RE: 1/C8.01 4' GATE 6 0 0 148 148 639 639 638 638 W W 640 640 SALVAGED BLEACHER W 641 641 W 642 642 W 644 644 DOUBLE GATE, 6' WIDE FOR MAINTENANCE 478 478 476 476 W 474 474 473 473 475 475 W 477 477 W WHEEL STOPS EACH SPACE 472 472 ADJACENT TO SIDEWALK RE: 439S-1/C8.03 471 471 248 248 PARKING LOT STRIPING 249 249 11' WIDE VAN ACCESSIBLE PARKING SPACE WITH 5' ACCESS AISLE B R O ( 3 O R K O 0' A V I D E R . W O . W .) 467 467 W W 466 466 468 468 469 469 W W W W W 463 463 5 . 0' WWCO W 470 470 9 . 0' 464 464 RD W W W 601 1 1 . 0' PLANTING BED W W 6 0 1 RD WWCO 6 0 0 ±1000 SF OF ASPHALT PAVEMENT RE: 2/C8.01 600 1046 EXISTING DRIVEWAY FOR TENNIS CENTER TO BE REMOVED AND REPLACED WITH 6' CONCRETE VALLEY GUTTER 6 0 1 1479 1479 RE: 436S-2/C8.03 ±360 SF OF ASPHALT REPLACEMENT STRIP FOR GRADE TRANSITION TO MATCH EXISTING GRADE RE: 2/C8.01 CITY OF AUSTIN VOL. 668, PG. 396 DRTCT TCAD 0217130301 1714-1/2 SCHIEFFER AVENUE RESOLUTION 520501-2 DEDICATED FOR PUBLIC PARK AND ROAD PURPOSES (10.327 ACRES) NEW SIGN LOCATION. REFER TO ARCH. FOR SIGN DETAILS 1175 1175 EXTERIOR LIGHTING NOTE: ALL EXTERIOR LIGHTING WILL BE FULL CUT-OFF AND FULLY SHIELDED IN COMPLIANCE WITH SUBCHAPTER E 2.5 AND WILL BE REVIEWED DURING THE BUILDING PLAN REVIEW. ANY CHANGE OR SUBSTITUTION OF LAMP/LIGHT FIXTURES SHALL BE SUBMITTED TO THE DIRECTOR FOR APPROVAL IN ACCORDANCE WITH SECTION 2.5.2.E. CITY OF AUSTIN LDC 25-2 SUBCHAPTER E - SECTION 2.5 - FIGURE 34 1 SITE PLAN SCALE: 1" = 30'-0" 0 15 30 60 NORTH SCALE 1" = 30'-0" OVERALL SITE PLAN EXHIBIT 2 SCALE: 1" = 120'-0" 6 0 1 6 0 3 LEGEND: ACCESSIBILITY NOTE: O E 5004 5004 O E LOC LIMITS OF CONSTRUCTION R.O.W. LINE ADA ACCESSIBLE PATH X X PROPOSED CHAIN LINK FENCE APPROVAL OF THESE PLANS BY THE CITY OF AUSTIN INDICATES COMPLIANCE WITH APPLICABLE CITY REGULATIONS ONLY. APPROVAL BY OTHER GOVERNMENTAL ENTITIES MAY BE REQUIRED PRIOR TO START OF CONSTRUCTION. THE APPLICANT IS RESPONSIBLE FOR DETERMINING WHAT ADDITIONAL APPROVALS MAY BE NECESSARY. PROPOSED WROUGHT IRON FENCE SLOPES ON ACCESSIBLE ROUTES MAY NOT EXCEED 1:20 UNLESS DESIGNED AS A RAMP. [ANSI 403.3]. PROJECT NAME PHARR TENNIS CENTER RENOVATIONS PROJECT ADDRESS 4201 BROOKVIEW RD AUSTIN, TX 78722 KIRKSEY PROJECT NO. 2019284 KEY PLAN ACCESSIBLE ROUTES MUST HAVE CROSS-SLOPE NO GREATER THAN 1:50 [ANSI 403.3]. ACCESSIBLE PARKING SPACES MUST BE LOCATED ON A SURFACE WITH A SLOPE NOT EXCEEDING 1:50. [ANSI 502.5] THE MAXIMUM SLOPE OF A RAMP IN NEW CONSTRUCTION IS 1:12. THE MAXIMUM RISE FOR ANY RAMP RUN IS 30". THE MAXIMUM HORIZONTAL PROJECTION IS 30 FEET OF RAMP WITH A SLOPE BETWEEN 1:12 AND 1:15, AND 40 FEET FOR A RAMP WITH A SLOPE BETWEEN 1:16 AND 1:20. [ANSI 405.2 - 405.6]. EXISTING SIDEWALKS TO REMAIN WITHIN THE LIMITS OF CONSTRUCTION HAVE BEEN VERIFIED TO COMPLY WITH THE APPLICABLE VERSION OF THE TEXAS ACCESSIBILITY STANDARDS, FEDERAL ADA REQUIREMENTS, AND CITY OF AUSTIN STANDARDS. CONCRETE PAD FOR TRASH AND RECYCLE BINS, TRASH AND RECYCLE BINS OFOI 534 534 1476 1476 185 LF OF REINFORCED CURB AND GUTTER RE: 430S-2/C8.02 (2) BIKE RACKS 600 FOR 4 BIKE PARKING SPACES 1492 1492 RE: 710S-1/C8.02 W 1114 1121 60' X 60' HALF-COURT RE: STRUCTURAL (2) BIKE RACKS FOR 4 BIKE PARKING SPACES (COVERED) S T M 4' GATED COURT ACCESS S PLANTING BED T M 5005 5005 O E 5006 5006 5179 5180 5182 S T M O E 5007 5007 5192 S T 5199 M 5193 5183 6 5200 120' X 120' TENNIS COURT RE: STRUCTURAL O 0 1 E S 6 0 T 0 M O 10' HIGH CHAIN LINK FENCE AT PERIMETER OF TENNIS COURTS, TYP. E E VOLUNTARY CLEANUP PROGRAM CONDITIONAL CERTIFICATE OF COMPLETION DOC. 2007006645 OPRTCT M T S 40 LF OF ORNAMENTAL FENCE. SEE LANDSCAPE FOR DETAIL 1491 1491 1399 1399 WALL WITH CHAIN LINK MOUNTED ON TOP. RE: STRUCTURAL 10' X 10' CONCRETE PAD FOR STORAGE SHED. S REFER TO STRUCTURAL T M FOR DETAILS W WW STM IRR ( 1 6 0 ' R . O . W . ) EXISTING WATER LINE EXISTING WASTEWATER LINE EXISTING STORM WATER LINE PROPOSED IRRIGATION LINE PROPOSED RETAINING WALL PROPOSED CONCRETE PAVEMENT PROPOSED DECOMPOSED GRANITE PROPOSED PLANTING BED PROPOSED ASPHALT PAVEMENT O E O E EXISTING TREE TRUNK 100% CRITICAL ROOT ZONE (CRZ) 50% CRITICAL ROOT ZONE (CRZ) XXXXX TREE TAG # EXISTING TREE TO REMAIN SHEET TITLE SITE PLAN SHEET ___ OF ___23 7 SPC-2020-0285D SHEET NUMBER C5.00 3 of 4B-17 4 of 4B-17