Building and Standards CommissionMay 13, 2021

Backup — original pdf

Backup
Thumbnail of the first page of the PDF
Page 1 of 13 pages

2021 International Property Maintenance Code (IPMC) Amendment Process Presented by 2021 IPMC Committee May 2021 Purpose of Presentation To provide an overview of the 2021 International Property Maintenance Code (IPMC) amendment process and share major proposed changes BACKGROUND  The City of Austin will adopt the International Code Council (ICC)’s 2021 IPMC updates from the current 2015 IPMC  Austin Code Department established an internal amendment committee to draft proposed amendments to the code  Purpose of proposed changes is to ensure public safety and maintain consistency with other city codes 2021 Code Adoption Timeline Primary goal The proposed amendments aim to ensure public safety when unsafe or hazardous conditions are found on a property by requiring: • Action plan for repairs from property owner Definition Action Plan: A written plan that identifies the repairs that are needed, the timeline needed for repairs, alternative methods of compliance, if necessary, and the projected finish date of the repairs. Major Changes in the 2021 IPMC Draft 111.1.3 Structure Unsafe for Human Occupancy A structure is unfit for human occupancy whenever the code official finds that such structure is unsafe, unlawful or, because of the degree to which the structure is in disrepair or lacks maintenance, is insanitary, vermin or rat infested, contains filth and contamination, or lacks ventilation, illumination, sanitary or heating facilities or other essential equipment required by this code, or because the location of the structure constitutes a hazard to the occupants of the structure or to the public. If the code official finds a structure unsafe, the owner of the property shall provide an action plan for repairs to the code official within two days of notice. Major Changes in the 2021 IPMC Draft 504.3 Plumbing system hazards Where it is found that a plumbing system in a structure constitutes a hazard to the occupants or the structure by reason of inadequate service, inadequate venting, cross connection, back siphonage, improper installation, deterioration, or damage or for similar reasons, the code official shall require the defects to be corrected to eliminate the hazard. If the code official finds a structure unsafe, the owner of the property shall provide an action plan for repairs to the code official within two days of notice. Major Changes in the 2021 IPMC Draft 505.4 Water heating facilities A water heating facility must be properly installed, maintained and capable of providing an adequate amount of water to be drawn at each sink, lavatory, bathtub, shower, and laundry facility at a temperature of not less than 110°F (43°C). If the code official finds a structure unsafe, the owner of the property shall provide an action plan for repairs to the code official within two days of notice. Major Changes in the 2021 IPMC Draft 602.2 Residential occupancies Heating facilities that are capable of maintaining a room temperature of 68°F (20°C) in habitable spaces, bathrooms, and toilet rooms are required in each dwelling unit. Cooking appliances and unvented fuel- burning space heaters cannot be used to meet or maintain the room temperature required by this section. A portable electric space heater may be used on a temporary basis if used consistent with manufacturer's specifications. If the code official finds a structure unsafe, the owner of the property shall provide an action plan for repairs to the code official within two days of notice. Major Changes in the 2021 IPMC Draft 604.3 Electrical System hazards If the code official finds that the electrical system in the structure constitutes a hazard to the occupants or the structure by reason of inadequate service, the owner of the property shall provide an action plan for repairs to the code official within two days of notice. 2021 Code Adoption Timeline Questions/Comments Please submit questions or comments using the Comments section of this page. If you have any additional questions, email codecommunications@austintexas.gov.