REGULAR CALLED MEETING BUILDING AND FIRE BOARD OF APPEALS Thursday November 19, 2026 @ 1:30 PM- In Person/Web Ex PERMITTING DEVELOPMENT CENTER/ 1st FLOOR, CONF RM 1401-1402 6310 WILHELMINA DELCO DR AUSTIN, TEXAS Public comment will be allowed in-person or remotely by telephone. Speakers may only register to speak on an item once either in-person or remotely and will be allowed up to three minutes to provide their comments. Registration no later than noon the day before the meeting is required for remote participation. To register, contact rick.arzola@austintexas.gov. CURRENT BOARD MEMBERS: Oren Mitnzer- Chair; Ben Abzug- Vice Chair; Brasfield, Aubrey; Buys, Ron; Gannon, Chris; McKay, Blair; Juarez, Cecilia Paredes; Rumbo, Jim; Satt, Alison; Schumann, Alan; Wood, William AGENDA CALL TO ORDER PUBLIC COMUNICATION: GENERAL The first 10 speakers signed up prior to the meeting being called to order will each be allowed a three-minute allotment to address their concerns regarding items not posted on the agenda. APPROVAL OF MINUTES- 1. Approve the minutes of the Building and Fire Board of Appeals Regular Called Meeting of September 23, 2026 DISCUSSION AND ACTION 2. Approve the 2027 annual schedule of the Building Fire Board of Appeals. 3. Approve a recommendation to council for the Houseplex Code Amendment FUTURE AGENDA ITEMS ADJOURNMENT The City of Austin is committed to compliance with the Americans with Disabilities Act. Reasonable modifications and equal access to communications will be provided upon request. For assistance, please contact the Liaison or TTY users’ route through 711. A person may request language access accommodation no later than 48 hours before the scheduled meeting. Please call or email Rick Arola at Austin Development Services Department, at 512-974-2417 or rick.arzola@austintexas.gov, to request service or for additional information. For more information on the Building and Fire Board of Appeals, please contact Rick Arzola at 512-974-2417 and rick.arzola@austintexas.gov
REGULAR CALLED MEETING BUILDING AND FIRE BOARD OF APPEALS Thursday November 19, 2026 @ 1:30 PM- In Person/Web Ex PERMITTING DEVELOPMENT CENTER/ 1st FLOOR, CONF RM 1407 6310 WILHELMINA DELCO DR AUSTIN, TEXAS Public comment will be allowed in-person or remotely by telephone. Speakers may only register to speak on an item once either in-person or remotely and will be allowed up to three minutes to provide their comments. Registration no later than noon the day before the meeting is required for remote participation. To register, contact rick.arzola@austintexas.gov. CURRENT BOARD MEMBERS: Oren Mitzner- Chair; Ben Abzug- Vice Chair; Brasfield, Aubrey; Buys, Ron; Gannon, Chris; McKay, Blair; Juarez, Cecilia Paredes; Rumbo, Jim; Satt, Alison; Schumann, Alan; Wood, William AGENDA REVISED CALL TO ORDER PUBLIC COMUNICATION: GENERAL The first 10 speakers signed up prior to the meeting being called to order will each be allowed a three-minute allotment to address their concerns regarding items not posted on the agenda. APPROVAL OF MINUTES- 1. Approve the minutes of the Building and Fire Board of Appeals Regular Called Meeting of September 23, 2026 DISCUSSION AND ACTION 2. Approve the 2027 annual schedule of the Building Fire Board of Appeals. 3. Approve a recommendation to council for the Houseplex Code Amendment FUTURE AGENDA ITEMS ADJOURNMENT The City of Austin is committed to compliance with the Americans with Disabilities Act. Reasonable modifications and equal access to communications will be provided upon request. For assistance, please contact the Liaison or TTY users’ route through 711. A person may request language access accommodation no later than 48 hours before the scheduled meeting. Please call or email Rick Arola at Austin Development Services Department, at 512-974-2417 or rick.arzola@austintexas.gov, to request service or for additional information. For more information on the Building and Fire Board of Appeals, please contact Rick Arzola at 512-974-2417 and rick.arzola@austintexas.gov
RECOMMENDATION TO COUNCIL Building and Fire Code Board of Appeals Recommendation Number: 20261119-3 Houseplex Code Amendment Date of Approval: November 19, 2026 Recommendation: The Building and Fire Code Board of Appeals recommends Staff’s draft code language on allowing three and four dwelling unit structures to be developed under the residential building code be adopted with additional provisions for enhanced life safety. Description of Recommendation to Council: The Building and Fire Code Board of Appeals recommends that the final code language be strengthened by adding the following provisions: ▪ Smoke alarms for all units should be interconnected regardless of configuration or if common egress space is included in the design. ▪ Electrical receptacles be prohibited in common egress spaces, as suggested in resolution no. 20260723-086. Rationale: The Board felt that while the draft language suggested by staff was well considered, providing for interconnected smoke alarms in all Houseplex structures would ensure that all occupants had adequate time to respond in the event of a fire in one unit, regardless of their unit’s proximity to the fire. The board also felt that removing electrical receptacles from common egress spaces would reduce the overall risk of fire as it would be less likely for devices such as lithium-ion batteries to be left plugged in and unattended. Motioned By: Abzug Seconded By: Paredes Vote: 6-1 For: Vice Chair Abzug, Ben; Brasfield, Aubrey; Buys, Ron; McKay, Blair; Paredes, Cecilia Juarez: Rumbo, Jim Against: Schumann, Alan Abstain: Chair Mitzner, Oren Off the dais: Gannon, Chris Absent: Satt, Alison, Wood, William Attest: __________________________________
Affordability Impact Statement Houseplex Code Amendment Land Development Code: Chapter 25-12 (Technical Codes) Initiated by: Resolution No. 20260723-086 Date: 10/30/2026 Proposed Regulation Following Resolution No. 20260723-086, the proposed ordinance amends the 2024 International Residential Code (IRC) so buildings with three or four attached units (“Houseplexes”) can be permitted under the residential code rather than the International Building Code (IBC). This would apply to Houseplexes up to and including four attached dwelling units that do not include internal common spaces or shared utilities and are limited to a maximum of three stories above grade plane. The IRC currently covers single-family homes, duplexes, and townhouses. Triplexes and fourplexes fall under the IBC, which carries additional engineering and construction requirements designed for commercial and large multifamily buildings. The proposed amendment includes additional safety considerations for three- and four-unit buildings to offset the safety risk of adding dwelling units, such as requirements for fire-safety and means of egress. Land Use/Zoning Impacts on Housing Costs The proposed changes would have neutral impacts on land use and zoning. The amendment does not change the number of units allowed on any lot, but it does make existing zoning entitlements more practical to build. The HOME amendments expanded the number of units allowed on a single-family lot but did not address the corresponding building code requirements. Allowing three- and four-unit buildings to be reviewed under the IRC helps align code with zoning and allows more units to fit on smaller lots. This helps support small-scale infill development that fits within existing neighborhood patterns and can be built by a wider range of homeowners, small contractors, or non-profit partners. Impact on Development Cost The proposed changes would have positive impacts on development costs. Building under the residential code is generally less expensive than the commercial code. Prescriptive residential design costs less than 1 commercial-grade engineering, and residential plan review and inspections are faster and less expensive than commercial review. Because these buildings are still restricted to three stories above grade plane, the IRC’s prescriptive structural requirements are generally sufficient. However, some situations may still require engineering, such as shared egress spaces that may exceed the load assumptions in the IRC. Under commercial code, buildings are required to have an NFPA 13R sprinkler system, which is costly to install. Allowing these buildings to use the residential-scale NFPA 13D system significantly reduces this cost while giving similar life-safety performance. Standard residential …
Austin’s 3-4 Dwellings Ordinance Austin Development Services November 12, 2026 Format for Today’s Session ▪ Presentation followed by question-and- answer session. ▪ Two ways to participate: ▪ Speak by raising your hand on the control panel. ▪ Written questions using the Q&A function at the bottom of your screen. 2 Significant Proposed Code Provisions Steve Leitch, Deputy Building Official & Chief Plans Examiner Residential Code Pathway This ordinance creates a residential code pathway for qualifying three- and four-unit buildings, with specific requirements addressing the additional units. ▪ Adds Appendix BP for qualifying buildings with three or four attached dwelling units ▪ Applies two-family dwelling requirements with additional safeguards ▪ Limits qualifying buildings to 6,000 gross square feet ▪ Applies to buildings other than townhouses 4 Fire Protection and Separation ▪ Allows an NFPA 13D system with some modifications to address Common Egress Spaces, parking spaces and exterior balconies and decks. Requires fire-resistance-rated separation between dwelling units ▪ Does NOT permit reductions in fire-resistance rated separations based on the presence of the sprinkler system ▪ Requires interconnected smoke alarms when units are stacked or when there is a Common Egress Space 5 Common Egress Space ▪ COMMON EGRESS SPACE: a portion of the means of egress that is a shared space, with or without stairs, that serves more than one dwelling unit. ▪ Requires a one-hour fire-resistance-rated separation from the remainder of the building ▪ Requires 45-minute-rated doors at openings to dwelling units and other interior spaces ▪ Requires gasketed, self-closing, self-latching doors ▪ Requires shared egress to discharge directly outdoors 6 Building Configuration and Ongoing Access ▪ Limits vertical stacking to two dwelling units ▪ Adds restrictions for habitable attics and occupiable roofs ▪ Retains structural engineering requirements when applicable ▪ Requires access agreements for inspection and maintenance of life-safety systems 7 Q&A Instructions Q&A Two ways to participate: ▪ Speak by raising your hand on the control panel. ▪ Written questions using the Q&A function at the bottom of your screen. 8 QR Codes with information Thank you! Submit Feedback https://publicinput.com/3-4_dwellingcode DSDCommunications@austintexas.gov 9
Proposed amendment seeks to add new Appendix BP to Residential Code. Working Document. Subject to Change APPENDIX BP THREE AND FOUR FAMILY DWELLINGS BP101 Scope. Three- and four-family dwellings that comply with this appendix shall be permitted to be constructed in accordance with this code. BP201 Definitions COMMON EGRESS SPACE: a portion of the means of egress that is a shared space, with or without stairs, that serves more than one dwelling unit. THREE- AND FOUR-FAMILY DWELLING: A single structure that does not exceed 6,000 square feet in gross floor area and contains three or four attached dwelling units that are not townhouse units. BP301 General. Three- and four-family dwellings shall comply with all requirements of this code that are applicable to a two-family dwelling, except as modified by this appendix. BP301.1 Engineered design. Where required by the code official, a structural design plan bearing the stamp of a licensed engineer shall be submitted with the permit application. BP302 Dwelling Unit Separation. Dwelling units shall be separated from each other and from common egress spaces by fire-resistance rated assemblies in accordance with the requirements in Section R302.3, except that the reduced rating for automatic sprinklers shall not be permitted. BP303 Common Egress Space. Common egress spaces shall comply with this section. BP303.1. Means of egress. Common egress spaces shall comply with Section R318, as would be required for a dwelling unit. BP303.2 Discharge. Common egress spaces shall discharge directly to the exterior of the building. BP303.3 Fire resistance rating. Common egress spaces shall be separated from the remainder of the building interior by assemblies having a fire-resistance rating of 1 hour. Vertical assemblies separating common egress spaces from the remainder of the building interior shall extend from the top of the foundation or floor below to the underside of the floor or roof sheathing, slab or deck above and shall be securely attached thereto. Such assemblies shall be continuous through concealed spaces. Proposed amendment seeks to add new Appendix BP to Residential Code. Working Document. Subject to Change BP303.3.1 Smoke-resistant construction. Fire-resistance rated vertical and horizontal assemblies separating common egress spaces from the remainder of the building interior shall be constructed in a manner that also limits the transfer of smoke. BP303.3.2 Fire-resistance rated doors. Doors connecting a common egress space to dwelling units or other interior spaces shall be 45-minute fire resistance rated and gasketed to prevent smoke transfer. …