Board of AdjustmentJan. 13, 2025

ITEM03 C16-2024-0002 PRESENTATION JAN13 — original pdf

Backup
Thumbnail of the first page of the PDF
Page 1 of 23 pages

St Davids North Austin Medical Center Exterior Signage Variance Request 13 January 2025 St Davids North Austin Medical Center Exterior Signage Variance Request ITEM03/1-PRESENTATION Directional Sign 38 B A A 56 B Directional Sign East Campus Entrance A 54 B Adult ED Entrance Main Campus Entrance B 2 A 2 North Campus Entrance B 37 A Directional Sign B 1 A 1 South Campus Entrance B 5 A Directional Sign 3 3 St Davids North Austin Medical Center Exterior Signage Variance Request SK2 20NOV2024 ITEM03/2-PRESENTATION LOCATION 1: Directional at Mopac and Cedar Bend Allowable: Height: 12'-0" Square Footage: 64 sf Proposed: Height: 11'-10" Square Footage: 58 sf Illumination: No internal face illumination Illumination: *Internal face illumination Set Back: At least 12 feet from the street right-of-way, or at least 25 feet from street pavement or curb in the right-of-way, whichever setback is the lesser distance from the street. Set Back: 3 feet from curb in the right- of-way; 0 feet from the right-of-way. *Red Text = Proposed design does not meet current code requirements Existing Condition: 10'-10"(h) x 6'-8"(w) 18' 16' 14' 12' 10' 8' 6' 4' 2' 7'-0" Emergency All Entrances Women’s Ctr " 0 1 - ' 1 1 LOCATION 1: Directional at Mopac and Cedar Bend St Davids North Austin Medical Center Exterior Signage Variance Request SK3 20NOV2024 ITEM03/3-PRESENTATION Location 1: Existing Conditions ITEM03/4-PRESENTATION Location 1: Existing Conditions ITEM03/5-PRESENTATION Location 1: Proposed Sign ITEM03/6-PRESENTATION Location 1: Existing Conditions ITEM03/7-PRESENTATION Location 1: Proposed Sign ITEM03/8-PRESENTATION LOCATION 2: Main Entrance Monument Allowable: Height: 12'-0" Square Footage: 64 sf Proposed: Height: *14'-9" Square Footage: *111 sf Illumination: No internal face illumination Illumination: *Internal face illumination Set Back: At least 12 feet from the street right-of-way, or at least 25 feet from street pavement or curb in the right-of-way, whichever setback is the lesser distance from the street. Set Back: 3 feet from curb in the right- of-way; 0 feet from the right-of-way. *Red Text = Proposed design does not meet current code requirements 18' 16' 14' 12' 10' 8' 6' 4' 2' Existing Condition: 10'-10"(h) x 8'-7"(w) 10'-0" " 9 - ' 4 1 Main Entrance Emergency LOCATION 2: Main Entrance Monument St Davids North Austin Medical Center Exterior Signage Variance Request SK4 20NOV2024 ITEM03/9-PRESENTATION Location 2: Main Entrance Existing Conditions ITEM03/10-PRESENTATION Location 2: Main Entrance Utility Easement New Sign Location Public Utility Easement Existing Sign ITEM03/11-PRESENTATION Location 2: Main Entrance Existing Conditions ITEM03/12-PRESENTATION Location 2: Main Entrance Existing Conditions ITEM03/13-PRESENTATION Location 2: Main Entrance Proposed Sign ITEM03/14-PRESENTATION Location 2: Main Entrance Existing Conditions ITEM03/15-PRESENTATION Location 2: Main Entrance Existing Conditions ITEM03/16-PRESENTATION Location 2: Main Entrance Proposed Sign ITEM03/17-PRESENTATION Location 2: Main Entrance Comparison ITEM03/18-PRESENTATION LOCATION 3: Directional at Mopac and Park Bend Allowable: Height: 12'-0" Square Footage: 64 sf Proposed: Height: *13'-11" Square Footage: *66 sf Illumination: No internal face illumination Illumination: *Internal face illumination Set Back: At least 12 feet from the street right-of-way, or at least 25 feet from street pavement or curb in the right-of-way, whichever setback is the lesser distance from the street. Set Back: 3 feet from curb in the right- of-way; 0 feet from the right-of-way. *Red Text = Proposed design does not meet current code requirements 18' 16' 14' 12' 10' 8' 6' 4' 2' LOCATION 3: Directional at Mopac and Park Bend St Davids North Austin Medical Center Exterior Signage Variance Request 7'-0" Emergency Children‛s Emergency Main Entrance Women’s Ctr - ' 3 1 " 1 1 Existing Condition: 10'-10"(h) x 6'-8"(w) SK1 9 20NOV2024 ITEM03/19-PRESENTATION Location 3: Existing Conditions ITEM03/20-PRESENTATION Location 3: Existing Conditions ITEM03/21-PRESENTATION Location 3: Proposed Sign ITEM03/22-PRESENTATION Signage Precedants along North Mopac Estimated Height = 20’ – Internally Illuminated Estimated Height = 25’ – Internally Illuminated Estimated Height = 30’ Estimated Height = 20’ – Internally Illuminated Estimated Height = 30’–35’ – Internally Illuminated St Davids North Austin Medical Center Exterior Signage Variance Request ITEM03/23-PRESENTATION