ITEM10 C15-2024-0045 ADV PACKET PART1 DEC9 — original pdf
Backup
BOA GENERAL REVIEW COVERSHEET CASE: C15-2024-0045 BOA DATE: Monday, December 9th, 2024 ADDRESS: 913 Capitol Ct OWNER: Justin Belmore COUNCIL DISTRICT: 7 AGENT: N/A ZONING:SF-3-NP (Brentwood) LEGAL DESCRIPTION: LOT 19 LADD N A ADDN VARIANCE REQUEST: Land Development Code, Section 25-2-773 (Duplex, Two-Unit, and Three-Unit Residential Uses) (B) (1) to decrease the minimum lot size from 5,750 square feet (required) to 5,158 square feet (requested). SUMMARY: complete a Two-Family Residential ISSUES: triangular shaped lot, property platted in 1916 long before the City adopted minimum lot standards. ZONING LAND USES SF-3-NP SF-3-NP Site North South UNZ East West SF-3-NP SF-3-NP Single-Family Single-Family Unzoned (state owned land) Single-Family Single-Family NEIGHBORHOOD ORGANIZATIONS: Austin Independent School District Austin Neighborhoods Council Brentwood Neighborhood Association Brentwood Neighborhood Plan Contact Team Friends of Austin Neighborhoods Homeless Neighborhood Association North Austin Neighborhood Alliance Preservation Austin Save Our Springs Alliance Shoal Creek Conservancy ITEM10/1November 25, 2024 Justin Belmore 913 Capitol Ct Austin TX, 78756 Re: C15-2024-0045 Property Description: LOT 19 LADD N A ADDN Dear Justin, Austin Energy (AE) has reviewed your application for the above referenced property, requesting that the Board of Adjustment consider a variance request from LDC Section 25-2- 733(B)(1) at 913 Capitol Court. Austin Energy does not oppose the request, provided that any proposed or existing improvements follow Austin Energy’s Clearance & Safety Criteria, the National Electric Safety Code, and OSHA requirements. Any removal or relocation of existing facilities will be at the owner’s/applicant’s expense. Please use this link to be advised of our clearance and safety requirements which are additional conditions of the above review action: https://library.municode.com/tx/austin/codes/utilities_criteria_manual?nodeId=S1AUENDECR_1 .10.0CLSARE If you require further information or have any questions regarding the above comments, please contact our office. Thank you for contacting Austin Energy. Rosemary Avila, Planning Officer Infrastructure Services | Austin Energy 4815 Mueller Blvd Austin, TX 78723 (512) 972-8488 Rosemary.avilla@austinenergy.com ITEM10/2ITEM10/3ITEM10/4ITEM10/5ITEM10/6ITEM10/7ITEM10/8(75') N62°20'34"W 74.84' 661 LOT 19 PROPOSED SECONDARY APARTMENT FFE XXX.X' AAG = XXX.X' 660.93' 660.73' MAIN AREA CALCULATIONS 640 910 1,550 ft² LOWER FLOOR UPPER FLOOR COPYRIGHT 2024 SALTBOX STUDIO THESE DRAWINGS AND THE DESIGN CONTAINED THEREIN OR WHICH MAY BE INFERRED THERE FROM ARE, AND AT ALL TIMES REMAIN, THE EXCLUSIVE PROPERTY OF SALTBOX STUDIO, WHO H O L D S T H E C O P Y R I G H T A N D OWNERSHIP IN THE SAID DRAWINGS, WHICH CANNOT BE USED FOR ANY PURPOSE WITHOUT WRITTEN CONSENT OF SALTBOX STUDIO, LLC. 5030 6 6 0.5 9' 660.52' ) ' 0 0 1 ( ' 1 1 . 3 0 1 ' W " 5 2 6 5 ° 7 2 S LOT 20 PROPOSED MAIN RESIDENCE FFE = XXX.X' AAG = XXX.X' 660.80' EXISTING POWER POLE 660.79' LOT 18 6 6 1 3' 5.1 7"E 11 5') (11 8'1 3°1 5 N 661.12' 661 C/O EXISTING CLEANOUT 6 6 1 . 3 2 ' 661.62' WV WM S60°48'38"E 25.53' R=35.00' L=26.13' (R=35.00' L=26') 913 CAPITOL COURT T.B.M.: MAG NAIL SET IN ASPHALT ELEV.: 660.69' NAVD 88 (GEOID18) COV'D GAR. SLAB ENTRY PORCH GARAGE 62 52 180 294 ft² 1,844 ft² MAIN FAR: 1730 SQ. FT. ADU AREA CALCULATIONS LOWER FLOOR UPPER FLOOR CARPORT ENTRY PORCH STORAGE 427 645 1,072 ft² 149 13 29 191 ft² 1,263 ft² ADU FAR: 1101 SQ. FT. TOTAL FAR: 2831 SQ. FT. (54.8%) IMPERVIOUS COVER --- TOTAL LOT: 5158 sq. ft. LOWER FLOOR CARPORT COV'D GAR. SLAB ENTRY PORCH GARAGE STORAGE A/C PAD CANTILEVER DRIVEWAY FLATWORK PATIO --- 0 ft² 1,067 1,067 ft² 149 62 65 180 29 485 ft² 18 28 665 55 766 ft² 2,318 ft² N BUILDING DESIGN | INTERIORS www.saltboxstudiodesigns.com TEL: 512.744.7302 , N O I T I D D A D D A L . . A N 9 1 T O L : I N O I T P R C S E D L A G E L X T , Y T N U O C S V A R T I 8 3 1 0 5 0 5 2 2 0 : D I I C H P A R G O E G 6 9 8 4 2 2 : D I Y T R E P O R P T R U O C L O T I P A C 3 1 9 X T , n i t s u A REVISION DATES: 2/25/24 | ISSUED FOR PRELIM. REVIEW 2/27/24 | ISSUED FOR CLIENT REVIEW DRAWN BY: SEM PROJECT START DATE: FEB. 22, 2024 CHECKED BY: SEM SITE PLAN SCALE 11x17: 1/16" = 1'-0" SCALE 11x17: 1/8" = 1'-0" SCALE 22x34: 1/8" = 1'-0" SCALE 22x34: 1/4" = 1'-0" (44.9%) SHEET A-1.01 ITEM10/9ITEM10/10ITEM10/11ITEM10/12ITEM10/13