D-12 C15-2021-0028 PRESENTATION — original pdf
Backup
LOT SIZE Name LOT MAXIMUM FAR Area 9,877 SF 3,950 SF TREE SCHEDULE # TREE TYPE PROTECTED TREE DIAMETER 7884 7885 7886 7887 7888 7889 7890 7891 7892 7893 A YES SPANISH OAK NO TALLOW YES PECAN YES PECAN TEXAS ASH NO MULBERRY NO NO PECAN YES PECAN NO PECAN YES PECAN YES PECAN 1' - 9" 1' - 2" 2' - 6" 1' - 10" 1' - 2" 0' - 9" 1' - 5" 1' - 7" 1' - 2" 2' - 7" 1' - 10" KEYNOTE LEGEND 508 509 530 531 533 1/4 CRITICAL ROOT ZONE - NO CUT OR FILL WITHIN THIS AREA 1/2 CRITICAL ROOT ZONE - NO CUT OR FILL GREATER THAN 4" WITHIN THIS AREA EXISTING BUILDING OVERLAPS 1/4" CRZ - NO DEMO IN THIS AREA EXISTING BUILDING OVERLAPS 1/2" CRZ - NO DEMO IN THIS AREA NEW PRIMARY STRUCTURE TO BE LOCATED A MINIMUM OF 10'-0" TO THE REAR OF EXISTING ADU 25' - 0" PROPERTY LINE PROPERTY LINE 7888 - TEXAS ASH 14"Ø NO SETBACK LINE SETBACK LINE EXISTING DRIVE 7889 - MULBERRY 9"Ø NO " 0 - ' 5 7890 - PECAN 17"Ø NO 7891 - PECAN 19"Ø YES 7885 - TALLOW 14"Ø NO 7886 - PECAN 30"Ø YES 220SF DEMO OF SINGLE STORY 10' - 0" 7892 - PECAN 14"Ø NO 509 508 E E N N I I L L G G N N D D L L I I U U B B I I K K C C A A B B T T E E S S T T N N O O R R F F 7887 - PECAN 22"Ø YES 509 508 531 EXISTING FRONT PORCH 1100SF EXISTING SINGLE STORY PROPOSED TO BE CLASSIFIED AS ADU NEW PRIMARY DWELLING IS PROPOSED TO BE CONSTRUCTED IN THIS AREA AT THE REAR OF THE LOT • PRIMARY DWELLING TO BE CONSRUCTED A MINIMUM OF 10'-0" BEHIND EXISTING STRUCTURE. FOOTPRINT TO AVOID 1/2 AND 1/4 CRZ FOOTPRINT TO REMAIN INSIDE SETBACK LINES FAR FOR PRIMARY STRUCTURE NOT TO EXCEED 2850SF FOR A SITE FAR NOT TO EXCEED 40% OR 3950SF BUILDING ENVELOPE TO REMAIN INSIDE MCMANSION TENT • • • • 533 509 530 508 7893 - PECAN 31"Ø YES " " 0 0 - - ' ' 5 5 SETBACK LINE SETBACK LINE PROPERTY LINE PROPERTY LINE " " 0 0 - - ' ' 5 5 W 10' - 0" 10' - 0" E E N N I I L L K K C C A A B B T T E E S S R R A A E E R R E E N N I I L L Y Y T T R R E E P P O O R R P P 509 508 A - PECAN 22"Ø YES T E E R T S S E L A Z N O G 509 508 E E N N I I L L Y Y T T R R E E P P O O R R P P 7884 - SPANISH OAK 21"Ø YES 530 23' - 9 1/2" 23' - 9 1/2" 7884 - SPANISH OAK 21"Ø YES 1 TREE PROTECTION PLAN SCALE: 1/8" = 1'-0" l t v r . 7 1 0 2 _ s e a z n o G _ 2 1 0 2 \ S E L A Z N O G \ d n a v r \ p o t k s e D \ 2 9 4 l f j \ s r e s U \ : C M P 7 5 : 6 0 : 2 1 1 2 0 2 / 3 / 5 CONSULTANTS LEGEND NOTES REVISION NO. DESCRIPTION DATE FOR INTERIM FOR INTERIM NOT TO BE USED FOR CONSTRUCTION, NOT TO BE USED FOR CONSTRUCTION, BIDDING OR PERMIT PURPOSES. BIDDING OR PERMIT PURPOSES. RESPONSIBLE ARCHITECT: JASON FRYER GONZALES A & B 3406 GONZALES ST TREE PROTECTION N N PLAN NORTH TRUE NORTH SCALE (FOR 11' X 17") HALF INDICATED SHEET SCALE (FOR 24" X 36") ISSUE DATE JOB # DRAWN BY A1.3 As indicated 04/15/21 2012 Designer D-12/1-PRESENTATION1 TREE 7884 - SPANISH OAK 21" DIAMETER SCALE: 1" = 1'-0" 2 TREE 7886 - PECAN - 30" DIAMETER SCALE: 1" = 1'-0" l t v r . 7 1 0 2 _ s e a z n o G _ 2 1 0 2 \ S E L A Z N O G \ d n a v r \ p o t k s e D \ 2 9 4 l f j \ s r e s U \ : C M P 6 0 : 7 0 : 2 1 1 2 0 2 / 3 / 5 3 TREE 7893 - PECAN 31" DIAMETER SCALE: 1" = 1'-0" 4 TREE 7887 - PECAN 22" DIAMETER SCALE: 1" = 1'-0" CONSULTANTS LEGEND NOTES REVISION NO. DESCRIPTION DATE FOR INTERIM FOR INTERIM NOT TO BE USED FOR CONSTRUCTION, NOT TO BE USED FOR CONSTRUCTION, BIDDING OR PERMIT PURPOSES. BIDDING OR PERMIT PURPOSES. RESPONSIBLE ARCHITECT: JASON FRYER GONZALES A & B 3406 GONZALES ST PROTECTED TREES SHEET SCALE (FOR 24" X 36") ISSUE DATE JOB # DRAWN BY A1.5 1" = 1'-0" 04/21/21 2012 Designer SCALE (FOR 11' X 17") HALF INDICATED D-12/2-PRESENTATIOND-12/3-PRESENTATIOND-12/4-PRESENTATIOND-12/5-PRESENTATIOND-12/6-PRESENTATION