Board of AdjustmentMarch 8, 2021

C-1 C16-2021-0006 PRESENTATON — original pdf

Backup
Thumbnail of the first page of the PDF
Page 1 of 12 pages

Exterior Sign Package 2101 Rio Grande St, Austin, TX 78705 Variance Request for 21 Rio Grande, Austin, Texas map view sign locations CASE # C16-2021-0006SPEAKER : JIM BECKETTPHONE NUMBER: (512) 947-2244EMAIL: C-1/1-PRESENTATION ILLUMINATION OF SIGNAGE IS GOING TO BE APPROVED AND UPDATED FORTHCOMING. MEMORANDUM TO: Members of the Planning Commission FROM: Jerry Rusthoven, Assistant Director/Interim Lead Planning and Zoning Department DATE: May 22, 2020 SUBJECT: UNO Sign Regulations The Planning and Zoning Department is requesting the Commission initiate an amendment to the UNO ordinance to correct an inadvertent change made to the sign regulations in the ordinance. In November 2019 the City Council approved changes to the UNO ordinance. One of those changes was intended to address signs above the second story of a building. Those signs were required to be cut in or engraved into the structure of the building. If the name of a building were placed on the facade this made it physically difficult to change the name in the future. It was agreed by the stakeholders to remove this requirement. In making this change to the ordinance a mistake was made and the result is all illuminated signs were prohibited in the UNO area. This is not what was intended or agreed to by the stakeholders. Also, because the UNO sign regulations are also used in TODs and the North Burnet/Gateway Plan this mistake carries over to other areas. Staff is asking for the opportunity to correct the ordinance. We will be working with the same stakeholders involved in the November revisions. If you need additional information, please contact me by email or 512-974-3207. Cc: Andy Linseisen, Assistant Director, DSD C-1/2-PRESENTATION THE NINE @ RIO THE NINE @ RIO 21 RIO RIO MART RIO MART RIO MART SIGNATURE 1909 SIGNATURE 1909 ILLUMINATION STUDY NIGHT PHOTOS OF NEIGHBORING SIGNS, DIM AND LOW ILLUMINATED AREAS C-1/3-PRESENTATION The only deviation from the code is allowing internally illuminated signage. Other aspects concerning quantities, square footage and projections all meet current code. C-1/4-PRESENTATION FIELD SURVEY REQUIRED FIELD SURVEY REQUIRED FIELD SURVEY REQUIRED PRIOR TO PRODUCTION PRIOR TO PRODUCTION PRIOR TO PRODUCTION REMOVE REMOVE REMOVE Existing SOUTH ELEVATION - BLADE SIGN A NIGHT Proposed Scale: nts C-1/5-PRESENTATION 29" 25" [1.] 4" 1 ¾" SEC. 1 8" 1" 2" [3.] P1 P2 V1 Akzo Nobel match PMS 418 C Akzo Nobel White ORACAL 8870 010 WHITE (OPAQUE) " ⅜ 5 1 " ⅝ 9 " 0 - ' 4 [4.] [2.] recessed area [2.] recessed area " 8 / 1 0 3 ¼" A E R A S I H T S P I R T S L Y N I V SCOPE: REMOVE EXISTING BLADE SIGN. MF & INSTALL NEW ILLUM. BLADE SIGN. [1.] SPECS FACE TYPE: .125 ALUM. WITH BORDER PTD. (P2), ; ROUTED OUT WITH ¾" CLEAR ACRYLIC PUSH-THRU WITH .040 ALUM. LAMINATED TO FACE PTD. (P1) WITH SEC. SURF. DIFFUSER; ILLUM. WITH 4100K WHITE LED. [2.] 'OVAL' FIELD, "RIO" TYPE: .040 ALUM. PTD. (P2) LAMINATE APPLIED TO RECESSED AREA. [3.] SPECS FILLER: ALUM. PTD. (P1) WITH ROUTED OUT STRIPE BACKED WITH #7328 WHITE ACRYLIC; APPLIED (V1) BETWEEN SUPPORTS FACING BLDG. CORNER; 4100K WHITE LED ILLUM.; HIDE SEAMS ON TOP OR SIDE WALL FACING THE BUILDING. [4.] SUPPORTS / PLATE SUPPORTS: TBD BY ENGINEERING AND PTD. (P1). PLATE: TBD BY ENGINEERING AND PTD. (P1).; ANCHORED TO WALL CORNER WITH REQUIRED FASTENERS. ALL VISIBLE FASTENERS COUNTER-SUNK AND PTD TO MATCH BACKGROUND. 120V CIRCUIT BY GC LEFT 11 ⅛" RIGHT SEC. 1 1 ½" = 1' A D/F BLADE SIGN QTY: ONE (1) SQ. FT. = 8.2 Scale: 1" = 1'-0" C-1/6-PRESENTATION C-1/7-PRESENTATION FIELD SURVEY REQUIRED FIELD SURVEY REQUIRED FIELD SURVEY REQUIRED PRIOR TO PRODUCTION PRIOR TO PRODUCTION PRIOR TO PRODUCTION ILLUMINATED " 8 / 7 1 - ' 2 1 WEST ELEVATION - CANOPY SIGN Scale: ¼" = 1' " 2 / 1 1 - ' 7 1 " 8 / 1 2 - ' 3 1 NIGHT C-1/8-PRESENTATION P1 P2 Akzo Nobel match PMS 418 C Akzo Nobel White SCOPE: MF & INSTALL NEW CANOPY SIGN. [1A.] MAIN BACKER CABINET FACE TYPE: .125 ALUM. PTD. (P2) WITH APPLIED PTD. VINYL (V1) TO MATCH (P1) WHERE '21' AND BORDER ARE WEEDED OUT SHO-THRU. RETURNS: 3" DEEP CUSTOM FAB. ALUM. BACKER CABINET PTD. (P2). BACKS: .125 ALUM. PTD. (P1). MOUNTING: TO VERTICAL SUPPORTS. SIDE VIEW @ "21" SIDE VIEW @ "RIO" [1B.] 'OVAL' BACKER CABINET FACE TYPE: .125 ALUM. PTD. (P1). RETURNS: 2" DEEP ALUM. PTD. (P1). ILLUM.: 4100K WHITE LEDs. MOUNTING: PIN-MOUNT OFFSET 1 ½" FROM MAIN BACKER CABINET. [2.] '21' REVERSE CHANNEL LETTERS FACE TYPE: .125 ALUM. PTD. (P2). RETURNS: 2" DEEP ALUM. PTD. (P2). ILLUM.: 4100K WHITE LEDs. MOUNTING: PIN-MOUNT OFFSET 1 ½" FROM MAIN BACKER CABINET. [3.] 'RIO' REVERSE CHANNEL LETTERS FACE TYPE: .125 ALUM. PTD. (P1). RETURNS: 3" DEEP ALUM. PTD. (P1). ILLUM.: 4100K WHITE LEDs. MOUNTING: PIN-MOUNT OFFSET 1 ½" FROM MAIN BACKER CABINET. CANOPY SIGN QTY: ONE (1) SQ. FT. = 32.23 Scale: 3/4" = 1'-0" [4.] VERTICAL SUPPORTS TYPE: 2" ALUM. SQ. TUBE PTD. (P1) MOUNTED TO RACEWAY. [5.] RACEWAY TYPE: 4.5 ALUM. EXTR. PTD. (P1). MOUNTING: TO CANOPY. ENGINEERING TBD. 120V CIRCUIT BY GC C-1/9-PRESENTATION FIELD SURVEY REQUIRED FIELD SURVEY REQUIRED FIELD SURVEY REQUIRED PRIOR TO PRODUCTION PRIOR TO PRODUCTION PRIOR TO PRODUCTION LOW LIGHTING, VERY DIM LOW LIGHTING, VERY DIM LOW LIGHTING, VERY DIM " 0 - ' 9 Existing ELEVATION - HANGING SIGN Scale: ½" = 1' NIGHT Proposed C-1/10-PRESENTATION P1 P2 Akzo Nobel match PMS 418 C Akzo Nobel White SCOPE: REMOVE EXISTING BLADE SIGN. MF & INSTALL NEW ILLUM. BLADE SIGN. [1.] SPECS FACE TYPE: .125 ALUM. WITH BORDER PTD. (P2), ; ROUTED OUT WITH ¾" CLEAR ACRYLIC PUSH-THRU WITH .040 ALUM. LAMINATED TO FACE PTD. (P1) WITH SEC. SURF. DIFFUSER. ILLUM: 4100K WHITE LED. [2.] 'OVAL' FIELD, "RIO" TYPE: .040 ALUM. PTD. (P2) LAMINATE APPLIED TO RECESSED AREA. [3.] 'ARROW, LEASING' SPECS TYPE: ¾" CLEAR ACRYLIC PUSH-THRU WITH SECOND SURFACE DIFFUSER. ILLUM: 4100K WHITE LED. [4.] SPECS FILLER: ALUM. PTD. (P1) WITH APPLIED VINYL STRIPES (V1) [5.] SUPPORTS / PLATE SUPPORTS: TBD BY ENGINEERING AND PTD. (P1). PLATE: TBD BY ENGINEERING AND PTD. (P1).; ANCHORED UNDER CANOPY WITH REQUIRED FASTENERS. ALL VISIBLE FASTENERS COUNTER-SUNK AND PTD TO MATCH BACKGROUND. 120v ELEC. BY G.C. C D/F HANGING SIGN QTY: ONE (1) SQ. FT. = 3.19 Scale: 1 ½" = 1'-0" C-1/11-PRESENTATION SIGN LOCATION C-1/12-PRESENTATION